Transcript
Firmware Release Note Product Model: SA-4540S Release Note: Date
Version
Description
2008/07/02
211A
1. Modify the reply data of SCSI inquiry command and its data length to fix DVR compatibility issue.
ECN No
2. Support LOG SENSE SCSI command to reply below log pages. - Log page 00h, Supported Log Pages - Log page 0Dh, Temperature - Log page 10h, Self-Test Results - Log page 2Fh, Informational Exceptions 3. Support CLI function. 4. Improve the Array recognition process during RAID system boot-up, when Array is in degrade mode and mixed spare disk on disordered disk location. 5. Includes updated MIB file. 6. Sends SNMP v2c traps with multiple-OID 7. Add disk SMART warning and bad block remapping SNMP traps. 2007/10/01
209A
1. Modify the reply data of SCSI inquiry command to support SPC-3 specification for LUN size over 2TB compatibility issue.
2007/08/31
208A
1. Support disk standby function.
4F., No.529, Chung Cheng Road, Hsin-Tien City, Taipei Hsien, Taiwan, R.O.C. Web Site: www.maxtronic.com.tw
Support:
[email protected]
2. Modify the fan fail threshold from 2400rpm to 2000rpm. 3. Update the LSI SCSI RISC code from 1.03.34.00 to 1.03.27.01 2007/03/06
207A
1. Modify the format of mail header to make it RFC compliant, in order to fix the problem which caused mails to be displayed incorrectly when mails are sent via Exchange mail server. 2. Fix the problem which caused the time in the mail to be 1970/1/1 0:0:0 when a warning status is cleared. 3. Fix the problem which caused the time in the mail to be incorrect when the time zone settings are changed. 4. Fix the problem caused by System Info mail when the content of system information is too large in size. 5. Fix message format problems, including the time string, alignment, etc. Also, System Info mail no longer displays disk temperature when the SMART function is not enabled (Previously displayed temperature 255 if SMART had not been enabled.) 6. Remove display messages of “un-support SCSI command.
2006/11/23
206A
1. Update the LSI SCSI RISC code (version: 1.03.34.00) for support LSI SCSI 1030T A3 chip. 2. Adjust the firmware behaviors to shorten the I/O response time during SMART function execution. - Avoid executing the SMART command with all existing disks at the same time. The performance may drop during PIO read (firmware will change the data transfer mode from eDMA mode to PIO, and read 512 bytes one by one) - For function to read disk surface temperature via ATA SMART command (PIO data-in, 512byte) The Original method: Sequentially read disk temperature from disk 1 to maximum in each 16 second time interval. Change to: Sequentially read disk temperature from disk 1 to maximum in each 16 seconds time interval only when SMART mode is enabled. - For function of "Test Disk SMART" Keep the original method: execute the SMART test with all existing disks at the same time. (this is a manual function, which executes immediately) 4F., No.529, Chung Cheng Road, Hsin-Tien City, Taipei Hsien, Taiwan, R.O.C. Web Site: www.maxtronic.com.tw
Support:
[email protected]
- For function of "disk check time" (periodically do SMART test after 60, 30, 15 and 1 minute) The Original method: execute the SMART test with all existing disks when the timer exceeds the preset value. Change to: Sequentially do SMART test from disk 1 to maximum in each 10 seconds time interval, when the timer expires. 3. Change the firmware handling procedures when the BBM is attached and array is R6 or TP, and the system is abnormally shutdown during Host I/O access. 4. Change the parity generation procedures when the user disabled PreRead, set stripe size to 1024(or 512) and created a parity based Array for Array parity check, Array init, or Host I/O access applications. 5. Notify the user to set SMTP mail account, if the user attempts to send event log mail without having set SMTP already. 6. Correct the display of hexadecimal numeric values display on the event log. 7. Fix the problem which may happen during socket creation procedures. 2006/10/26
204A
1. Add Chassis Description (for mail messages) in NVRAM 2. Add SNMP Trap configuration settings in NVRAM 3. Modify the "Shutdown" function process rule - system halt after shutdown success. 4. Fix LCD warning message display problem which caused warning message on the 2nd line of the LCD to remain after the warning is cleared. 5. Support new battery module (ACS1162). Modified I2C program (delayed 1 ms before issue control data to target I2C device) for battery power start/stop control. 6. Correct problems with displaying messages Set IP, Subnet mask, Gateway, DNS on terminal when DHCP is enabled. 7. Modify the process rule for BBM temperature to filter out unreasonable temperature readings.
4F., No.529, Chung Cheng Road, Hsin-Tien City, Taipei Hsien, Taiwan, R.O.C. Web Site: www.maxtronic.com.tw
Support:
[email protected]
2006/01/19
202A
1. Modify the Fan speed control to increase +200RPM for Arena 89312. a. Max temperature less than 40'C -> 2900 RPM b. Max temperature between 41 and 44'C -> 3200RPM c. Max temperature large than 44'C -> 3800RPM d. Any Fan or Power module fail -> 3800RPM
If you have any question about our products, please email to:
[email protected] Thank you!
4F., No.529, Chung Cheng Road, Hsin-Tien City, Taipei Hsien, Taiwan, R.O.C. Web Site: www.maxtronic.com.tw
Support:
[email protected]