Preview only show first 10 pages with watermark. For full document please download

First-step_msel_me0337

   EMBED


Share

Transcript

5. How to read the model of the controller Basic Specifications Single-Axis and Cartesian Type Controllers MSEL-PC-2-56PS A-42PSAB-NP-CC-2-4-ABB-DN-** MSEL First Step Guide Third Edition Thank you for purchasing our product. Make sure to read the Safety Guide and detailed Instruction Manual (DVD) included with the product in addition to this First Step Guide to ensure correct use. This Instruction Manual is original. Warning : Operation of this equipment requires detailed installation and operation instructions which are provided on the DVD Manual included in the box this device was packaged in. It should be retained with this device at all times. A hardcopy of the Manual can be requested by contacting your nearest IAI Sales Office listed at the back cover of the Instruction Manual or on the First Step Guide. • Using or copying all or part of this Instruction Manual without permission is prohibited. • The company names, names of products and trademarks of each company shown in the sentences are registered trademarks. * There is no identification in some cases. PC : Standard type PG : Safety category compliant type Not Specified : Screw attachment type DN : DIN Rail Mounting type ABB : Simple absolute (with battery box) ABBN : Simple absolute (without battery box) Connected Axis> 1~4 : Number of driver axis 20P 20SP 28P 28SP 35P 42P 56P : : : : : : : 20□ pulse motor 20□ pulse motor 28□ pulse motor 28□ pulse motor 35□ pulse motor 42□ pulse motor 56□ pulse motor 4 : 100 to 230V AC 0 : Equipped with no cable 2 : 2m (Standard) 3 : 3m 5 : 5m [Encoder Type] WAI : Incremental/batteryless absolute SA : Simple absolute E : Not use NP : NPN (Sink Type) PN : PNP (Source Type) DV : DeviceNet DV2 : DeviceNet (Multidrop connector enclosed) CC : CC-Link CC2 : CC-Link (Multidrop connector enclosed) PR : PROFIBUS-DP EP : EtherNet/IP [Optional] HS : Homeposition check sensor B : Brake NP : NPN (Sink Type) PN : PNP (Source Type) Product Check The standard configuration of this product is comprised of the following parts. If you find any fault with the product you have received, or any missing parts, contact us or our distributor. 1. Parts No. 1 Part Name Model Refer to “How to read the model plate”, “How to Controller Main Body read the model”. Quantity Reference SCARA Robot Controller 1 M S E L-PCX4- 3N4515WAI - 5 6 P WAI- NP - DV -2-4 -DN -* * Accessories 2 System I/O Plug DMC1.5/6-ST-3.5 (Supplier : PHOENIX CONTACT) 1 3 AC Power Plug MSTB2.5/3-STF-5.08 (Supplier : PHOENIX CONTACT) 1 4 Dummy Plug DP-4S (Enclosed only in PG or PGX) 1 5 6 7 8 9 I/O Flat Cable 1 (Standard only) 2 (Standard + Extension) CB-PAC-PIO□□□ Model CC : MSTB2.5/5-STF-5.08AU (Supplier : PHOENIX CONTACT) Model CC2 : TMSTBP2.5/5-STF-5.08 AU (Supplier : PHOENIX CONTACT) Model DV : MSTB2.5/5-STF-5.08AU (Supplier : PHOENIX CONTACT) DeviceNet Connector Model DV2 : TMSTBP2.5/5-STF-5.08 AUM (Supplier : PHOENIX CONTACT) Instruction Manual (DVD) First Step Guide CC-Link Connector 1 1 Recommended cable size 1.25 to 0.3mm2 (AWG16 to 22) Recommended cable size 1.25 to 0.5mm2 (AWG16 to 20) □□□ shows the cable length (Example) □□□ : 020 = 2m Terminal Resistance (130Ω1/2W, 110Ω1/2W) One each enclosed Prepare a terminal resistor separately when this controller is on the terminal. 1 1 2. Teaching Tool (to be purchased separately) A teaching tool such as PC software is necessary when performing the setup for position setting, parameter setting, etc. that can only be done on the teaching tool. Please prepare either of the following teaching tools. No. Part Name Model 1 PC Software (with RS232C Cable + Connector Conversion Cable ・ Emergency Stop Box) IA-101-X-MW-JS 2 PC Software (with USB Cable (CB-SEL-USB030) + Dummy Plug (DP-4S)) IA-101-X-USBS 3 Teaching Pendant 4 Teaching Pendant (Dead man's switch) TB-01 TB-01D, TB-01DR 3. Instruction Manuals related to this product, which are contained in the Instruction Manual (DVD). No. 1 2 ME0154 ME0325 ME0124 ME0123 ME0153 ME0308 ME0140 4. How to read the model plate MODEL MSEL-PCX4-3N4515WAI-56PWAI-NP-CC-2-4-DN-** 4 : 100 to 230V AC 0 : Equipped with no cable 2 : 2m (Standard) 3 : 3m 5 : 5m E : Not use NP : NPN (Sink Type) PN : PNP (Source Type) DV : DeviceNet DV2 : DeviceNet (Multidrop connector enclosed) CC : CC-Link CC2 : CC-Link (Multidrop connector enclosed) PR : PROFIBUS-DP EP : EtherNet/IP < Standard I/O Type > NP : NPN (Sink Type) PN : PNP (Source Type) 20P : 20□ pulse motor, 20SP : 20□ pulse motor, 28P : 28□ pulse motor, 28SP : 28□ pulse motor, 35P : 35□ pulse motor, 42P : 42□ pulse motor, 56P : 56□ pulse motor [Encoder Type] WAI : Incremental / Battery-less absolute shared [Optional] HS : Home-position check sensor B : Brake (Standard / External Extension)PIO Interface (Dedicated for Extension) Fieldbus Data Setting and Input Program Specification Max. Number of Program Steps Max. Number of Positions Max. Number of Programs Max. Number of Multitask Programs Data Retention Memory DeviceNet, CC-Link, PROFIBUS-DP, EtherNet/IP (Note 4) PC software or teaching pendant SEL Language 9999 steps 30000 position 255 program 16 program Flash ROM and FeRAM Retaining time after power turned OFF: approximately 10 days Time for battery charge after the clock data is lost: approximately 100 hours Emergency stop input, safety gate input Contact point for semiconductor (connect externally such as driving source cutoff relay when required to comply with Safety Categories for PG/PGX Types) Clock Function System I/O Drive-source Cutoff Method Safety Circuit Configuration Emergency-stop Input Enable Input b Contact (Normally closed) Input (Internal power supply) Protective Functions Protection Function Against Electric Shock Overvoltage Category Insulation Resistance Insulation Strength Protection Conduction Cooling Method Surrounding Air Temperature Surrounding Humidity Surrounding Environment Surrounding Storage Temperature Environment Surrounding Storage Humidity Maximum Operation Height Vibration Resistance Protection Class Pollution Degree External Dimensions Mass b Contact (Normally closed) Input (Internal power supply) Motor over current, overload, encoder open circuit detection, soft limit over, system abnormality, battery abnormality Class I In case grounding conducted on ground terminal in addition to basic insulation for electric shock proof. Category II Voltage durability 2500V at less than 300V AC for input rating 10MΩ or more (Between power terminal and I/O terminal and also all external terminals and case at the power supply of DC500V) 1500V AC for 1 min (between Primary and PE) 3000V AC for 1 min (between Primary and Secondary) 10A 1.0V or less (for 10sec) Forced Air-Cooling 0 to +40°C 85% RH or less (non-condensing) (Refer to the Item for the Installation Environment). -20 to 70°C (Note) 0 to 40°C for absolute battery 85% RH or less (non-condensing) 1000m 10 to 57 Hz in XYZ directions Swing width: 0.075mm, 57 to 150Hz IP20 Pollution degree 2 [Refer to the External Dimensions] Approx. 1.4kg Acceleration: 9.8m/s2 Note 1 Rush current at the power connection continues for 5 msec. Note that the value of in-rush current differs depending on the impedance of the power supply line. Note 2 Leak current varies depending on the capacity of connected motor, cable length and the surrounding environment. Measure the leak current at the point where a ground fault circuit interrupter is to be installed when leakage protection is conducted. Regarding the leakage breaker, it is necessary to have a clear purpose for selection such as a fire protection or protection of human body. Use the harmonic type (for inverter) for a leakage breaker. Note 3 Power supply is not necessary if PIO is not to be used. Note 4 EtherNet/IP can also communicate with EtherNet. Standard I/O Interfaces Specification Input Output Input voltage 24V DC±10% Load voltage Input current 7mA 1 circuit Peak load electric current Specification ON/OFF voltage ON voltage OFF voltage MIN. 16V DC MAX. 5V DC Leak Current 24V DC ±10% 100mA/1 Circuit, *1 (Note 1) 400mA / 8 Port MAX. 2mA/1 point Insulation with external circuit and photocoupler NPN External Power + Source 24V DC ±10% 560Ω Intput Terminal PNP External Power + Source 24V DC ±10% Intput Terminal 560Ω + - Outtput Terminal MSEL The total of lead current reaches max. 400mA every 8 ports from output port No. 300. Load MSEL External Power Source 24V DC ±10% 10Ω 3.3kΩ Note 1 Load Output Terminal MSEL MSEL MADE IN JAPAN 10Ω 3.3kΩ Internal circuit SERIAL No.200198765 Not Specified : Screw attachment type DN : DIN rail mounting type Leakage Current (Note 2) Transient Power Cutoff Durability Heat Generation PIO Power Supply (Note 3) Motor Control System Applicable Encoder Actuator Cable Length Serial Communication Interface (SIO port or USB port) Internal circuit Model Serial Number 3N1808WAI : 3 axes (not Rotation Controls) : Arm Length180mm 3N2508WAI : 3 axes (not Rotation Controls) : Arm Length 250mm 3N3515WAI : 3 axes (not Rotation Controls) : Arm Length 350mm 3N4515WAI : 3 axes (not Rotation Controls) : Arm Length 450mm 3N5520WAI : 3 axes (not Rotation Controls) : Arm Length 550mm 3N6520WAI : 3 axes (not Rotation Controls) : Arm Length 650mm 3N1808GMWAI : 3 axes (not Rotation Controls, Gripper GRSML Equipped) : Arm Length 180mm 3N2508GMWAI : 3 axes (not Rotation Controls, Gripper GRSML Equipped) : Arm Length 250mm 3N3515GMWAI : 3 axes (not Rotation Controls, Gripper GRSML Equipped) : Arm Length 350mm 3N4515GMWAI : 3 axes (not Rotation Controls, Gripper GRSML Equipped) : Arm Length 450mm 3N3510GLWAI : 3 axes (not Rotation Controls, Gripper GRSLL Equipped) : Arm Length 350mm 3N4510GLWAI : 3 axes (not Rotation Controls, Gripper GRSLL Equipped) : Arm Length 450mm 3N5515GLWAI : 3 axes (not Rotation Controls, Gripper GRSLL Equipped) : Arm Length 550mm 3N6515GLWAI : 3 axes (not Rotation Controls, Gripper GRSLL Equipped) : Arm Length 650mm 3N5515GWWAI : 3 axes (not Rotation Controls, Gripper GRSWL Equipped) : Arm Length 550mm 3N6515GWWAI : 3 axes (not Rotation Controls, Gripper GRSWL Equipped) : Arm Length 650mm 4N1808WAI : 4 axes (with Rotation Controls), : Arm Length 180mm 4N2508WAI : 4 axes (with Rotation Controls), : Arm Length 250mm 4N3515WAI : 4 axes (with Rotation Controls), : Arm Length 350mm 4N4515WAI : 4 axes (with Rotation Controls), : Arm Length 450mm 4N5520WAI : 4 axes (with Rotation Controls), : Arm Length 550mm 4N6520WAI : 4 axes (with Rotation Controls), : Arm Length 650mm [Optional] B : Brake (Arm Length 550mm/650mm is set) * There is no identification in some cases. Rush Current (typ value) (Note 1) Internal circuit SEL Language Programming Manual PC Software IA-101-X-MW-JS/IA-101-X-USBS Instruction Manual Touch Panel Teaching TB-01/TB-01D Instruction Manual DeviceNet Instruction Manual CC-Link Instruction Manual PROFIBUS-DP Instruction Manual EtherNet/IP Instruction Manual Ethernet Instruction Manual Manual No. ME0224 PCX3 : 3 axes standard type PGX3 : 3 axes safety category compliant type PCX4 : 4 axes standard type PGX4 : 4 axes safety category compliant type 1-axis to 4-axis (Total of RC axis or SCARA axis + RC axis is four axes max.) Single-phase 100V to 230V AC ±10% 2.9A (100V AC), 1.4A (200V AC), 1.2A (230V) 50Hz/60Hz±5% 15A (100V AC), 30A (200V AC) (Ambient Temp. 25°C, Measurement in one time of turn-ON: when no repeating of ON/OFF) 0.75mA or less 20ms or more 40W (100V AC), 35.2W (200V AC), 30.4W (230V AC) 24V DC ±10% (Supplied from external equipment) Weak field-magnet vector control Battery-less absolute encoder or Incremental encoder resolution 800pulse/rev MAX. 20m (when simple absolute type is used Max.10m) Teaching tool dedicated connector (SIO ports and USB ports excluded) (XSEL Serial Communication Protocol (Format B)) 24V DC general-purposed signal I/O (NPN / PNP selection) Input 32 points max., output 32 points max. (Total of standard and extension) Cable length MAX.10m Internal circuit 3 4 5 6 7 8 Name Specification Item Number of Controlled Axes Power Supply Voltage Power Current (typ value) Power Supply Frequency + - External Power Source 24V DC ±10% NPN Specification consider to avoid condensation of surrounding air. Unless specially specified, moisture absorbency protection is not included in the package when the machine is delivered. In the case that the machine is to be preserved in an environment where dew condensation is anticipated, take the condensation preventive measures from outside of the entire package, or directly after opening the package. PNP Specification Pin No. Pin No. 1) Connection of Linear Axes MSEL Installation and Noise Elimination Load MPG1 Actuator Connection Connector 1. Noise Elimination Grounding (Frame Ground) Load Other equipment Controller Added axis (RCP series) MPG0 MPG2 AC power supply MPG3 Controller Other equipment Strand or annealed copper wire [1.25mm2(AWG16)] External Dimensions • Main Body Do not share the ground wire with or connect to other equipment. Ground each controller. Protective grounding (PE) 2 Precautions Regarding Wiring Method Surge Absorber 1) Use a twisted cable for connection to the power supply. 2) To reduce the interference to each other, have the I/O line, communication and encoder lines, power and driving supply lines separate from each other. R Relay coil 3 Noise Sources and Elimination 125 130 4-φ4.5 185 3 (10.9) 5.9 3 (75mm from DIN Rail center) 116 Other equipment Carry out noise elimination measures for power devices on the same power path and in the same equipment. The following are examples of measures to eliminate noise sources: 1) AC solenoid valves, magnet switches and relays [Measure] Install a Surge Absorber parallel with the coil. 2) DC solenoid valves, magnet switches and relays [Measure] Install a diode parallel with the coil. Use a DC relay with a built-in diode. 2) Connection to IXP-4N3515, 4515 and IXP-3N3515, 4515 Equipped with Grippers. CB-CAN-MPA††† (††† : cable length Example) 030 = 3 m) MSEL C MPG0 When equipped with grippers Relay coil +24V 0V Actuator Connection Connector MPG2 + - +24V 0V Conduct design and manufacture in consideration of the control box size, controller layout and cooling in such a way that the temperature around the controller will be 40°C or less. In case of layout with multiple controllers aligned vertically, consider not to have exhaust of bottom side controllers flow directly to the inlet of the upper controllers. Especially around the battery, the performance may drop in both low and high temperature. Keep it in ambient temperature as much as possible. (Approximately 20°C is the recommended temperature.) Direction Method Vertical Installation (Exhaust on top) Screw attachment or DIN rail attachment 3) Connection to IXP-3N3515, 4515 and Additional Axes Connection cable (Note 1) MSEL Fan 30mm or more MPG0 Air flow Air flow Ceiling • Absolute Battery Box (Simple Absolute Type) 100mm or more 30mm or more Actuator Connection Connector 20mm or more MPG1 MPG2 5 MPG3 10.5 4 (4) 115 98 Air inlet (59mm from DIN Rail center) 123 φ5 108 5 150mm or more Air outlet Added axis (RCP series) 111 φ5 CB-IXP-AT008-AS MPG3 4. Heat Radiation and Installation Installation MPG1 50mm or more Air flow Connection Diagram Teaching Tool (Option) Installation Environment Actuator (IXP) Safety Circuit (Note 1) (Enable) This product is capable for use in the environment of pollution degree 2*1 or equivalent. *1 Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive pollution by frost (IEC60664-1) Emergency Stop (Note 1) 1. Installation Environment Do not use this product in the following environment • Location where the surrounding air temperature exceeds the range of 0 to 40°C • Location where condensation occurs due to abrupt temperature changes • Location where relative humidity exceeds 85%RH • Location exposed to corrosive gases or combustible gases • Location exposed to significant amount of dust, salt or iron powder • Location subject to direct vibration or impact • Location exposed to direct sunlight • Location where the product may come in contact with water, oil or chemical droplets • Environment that blocks the air vent [Refer to Installation and Noise Elimination] When using the product in any of the locations specified below, provide a sufficient shield. • Location subject to electrostatic noise • Location where high electrical or magnetic field is present • Location with the mains or power lines passing nearby 2. Storage and Preservation Environment • Storage and preservation environment follows the installation environment. Especially in a long-term storage, Actuator (RCP Series) Power Supply (Single-phase AC100~230V) PIO N L Fieldbus Host Device (Note 1) Absolute Battery Box MSEL-ABB-□ (when simple absolute type is used) CB-MSEL-AB005 Contact for Cutoff (Note 1) (when supplying / cutting off power source externally) Note 1 Applicable Connection Cable Model No. ††† : cable length Example) 030 = 3 m Model Cable Remarks RCP2 CB-PSEP-MPA††† Robot cable from 0.5 to 20m CB-APSEP-MPA††† Robot cable from 0.5 to 20m RCP3 CB-APSEP-MPA†††-LC Standard cable from 0.5 to 20m RCP4 CB-CA-MPA†††-RB Robot cable from 0.5 to 20m (except for GR* Type) CB-CA-MPA††† Standard cable from 0.5 to 20m RCP4(GR* Type), RCP5, CB-CAN-MPA†††-RB Robot cable from 0.5 to 20m IXP CB-CAN-MPA††† Standard cable from 0.5 to 20m Caution: In such case, give a number to each connector to avoid any mistake. If the cable is not correctly connected, it might cause a damage to or malfunction of the motor or PCB board. Emergency Stop Circuit PIO This shows the circuit example when the emergency stop switch in the teaching pendant is enabled on the emergency stop circuit to be built up by the client. z PC/PCX Type Teaching pendant 24V 0V DeviceNet [Refer to the instruction manuals for DeviceNet] (1) I/O Map Type Port No. Internal DI 000~015 Function Type Internal DO For future expansion Port No. 300 Function ALM (LED on the front panel) 301 RDY (LED on the front panel) 302 EMG (LED on the front panel) 303 For future expansion White 304 HPS (LED on the front panel) None For future expansion Alarm output (Note) Blue 305~315 Program start (Note) 016 SIO Connector 3 017 317 READY output 018 318 Emergency-stop output (Note) 2 019 System I/O Connector VP24S 5.ENBOUT CR2 (Note 4) Safety gate 6.ENBIN 6 CR1 (Note 4) 12.EMGIN 5 7 4.ENBS1+ Emergency stop reset Emergency stop switch switch 3 4 2 EMB Status detection 8.EMGS2+ 321 022 024 025 Program number specification AUTO 7.EMGS210.EMGS1+ 328 029 329 General-purpose input Internal DO For future expansion MPO MC1 (Note 3) 24V Green/Orange 7-segment user display digit 333 334~336 7-segment user display digit For future expansion 337 7-segment display refresh 338 7-segment user/system alternate 7-segment user display specification DT0~6 (7-segment user display bit) For future expansion MPI Extension I/O (input side) (I/O2) CR2 (Note 5) Note MC1 048~295 (16 points selected from this range) Extension I/O (output side) (I/O2) General-purpose input Green NS - Master Unit RD (V+) General-purpose output WT (CAN H) BL (CAN L) 0V (NPN Type) 24VDC (PNP Type) RD V+ WT CAN_H Terminal Resistance 121Ω Self-testing No power supply confirmed Online, Communication in normal condition Online, No connection established Critical link error Connection timeout Self-testing Offline/No power supply confirmed Slave Devices RD WT Drain (Shield) Shield The dedicated functions set in the standard I/O board can be changed by the settings in I/O Parameter No. 30 to 61. (Note 4) Orange Green/Orange (2) Wiring (Standard type I/O) CR1 z PG/PGX Type 348~595 (16 points selected from this range) { œ œ (Blink by turn) ¯ { œ { ☆ œ (Blink by turn) ¯ Orange 331 332 Description Normal Operation Configuration setting not established or not complete, test run required An error that cannot be recovered An error that can be recovered œ 330 347 CR1 (Note 5) BL CAN_L BK V- BL BK BK (V-) 24VDC (NPN Type) 0V (PNP Type) Terminal Resistance is required to be mounted on the terminal. Terminal Resistance MSEL 121Ω V+ V+ RD CAN_H CAN_H WT Drain (Shield) Drain (Shield) CAN_L CAN_L BL V- V- BK 24V Power Supply Class D grounding (Formerly Class-III grounding: Grounding resistance at 100W or less) Communication power needs to be supplied by an external device. Teaching pendant 24V 0V 24VDC Output function is parameter setup SIO Connector 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 System I/O Connector VP24S 5.ENBOUT CR2 (Note 4) Safety gate ENB Status detection 6.ENBIN 2.ENBS2+ 1.ENBS24.ENBS1+ 3.ENBS1VP24S 11.EMGOUT Emergency stop reset Emergency stop switch switch MS 340~346 Motor driving circuit Dedicated cable for DeviceNet { : Illuminating ¯ : OFF œ : Flashing Green 339 Motor driving power supply line connector Applicable cable diameter Lamp condition { Color General-purpose output 9.EMGS1- CR1 (Note 4) CAN L (BL) Shield (None) CAN H (WT) V+ (RD) LED 325 028 032~047 V- (BK) 2 3 4 5 Description Power Supply Cable Negative Side Communication Data Low Side Shield Communication Data High Side Power Supply Cable Positive Side Monitoring LED 324 327 Signal Name (Color) 1 326 (Note) 030 Internal DI 322 323 027 031 (Note 2) yMANU mode 2-3 and 6-7 short-circuited yAUTO mode 3-4 and 5-6 short-circuited Standard I/O (output side) (I/O1) 023 026 1.ENBS2- 3.ENBS1VP24S 11.EMGOUT Standard I/O (input side) (I/O1) ENB Status detection 2.ENBS2+ 320 021 Enclosed in standard package Manufactured by PHOENIX CONTACT MSTBA2.5/5-G-5.08 ABGY AU Pin No. 319 General-purpose input 020 (Note 1) yTeaching pendant connected 2-3 and 6-7 short-circuited yTeaching pendant disconnected 3-4 and 5-6 short-circuited 7 Controller Side Black (Note) 4 5 6 316 Connector Name DeviceNet Connector Cable Side MSTB2.5/5-ST-5.08 ABGY AU Red CR1 (Note 4) 12.EMGIN EMB Status detection CC-Link 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 [Refer to the instruction manuals for CC-Link] Connector Name CC-Link Connector Cable Side SMSTB2.5/5-STF-5.08AU Controller Side 1 2 3 4 Input function is parameter setup 5 0V Model : CB-PAC-PIO††† (††† indicates the cable length L. Example. 020 = 2m) 9.EMGS1- MC1 (Note 3) MPI 24V RUN Green ERR Orange L Motor driving circuit { { œ BK-4 (20B) CR1 (Note 5) CR2 (Note 5) MC1 CR1 (Note 4) Note 1: EMGS1+ and EMGS1- make short-circuit inside the controller if a teaching pendant is not connected. Note 2: In AUTO Mode, short-circuit is made between ENBS1+ and ENBS1- inside the controller. Note 3: When it is necessary to cut off the motor power source externally for such reason as to comply with Safety Category, connect a contact such as a connector on the wire between MPO and MPI terminals on the motor driving power line connector. Shown below is table for the power specifications between MPO and MPI terminals. Specifications Voltage 24V DC (Built-in power supply) Rated current 2A/ axis ⋅ ⋅ ⋅ 1 axis type : 2A to 4 axis type : 8A Maximum current 4A/ axis ⋅ ⋅ ⋅ 1 axis type : 4A to 4 axis type : 16A Note 4: The ratings for the emergency stop signal (EMGIN) that turns ON/OFF at the contact CR1 and the enable signal (ENBIN) that turns on/off at the contact CR2 are 24V DC and 10mA or less. The emergency stop output (EMGOUT) and the enable output (ENBOUT) are available for connection to 30V DC and 0.5A or less. Note 5: For CR1 and CR2, select the one with coil current 0.1A or less. No treatment conducted B 20A Communication Line A Communication Line B Digital GND Connect the shield of the shielded cable Frame Ground Dedicated cable for CC-Link Lamp condition Motor driving power supply line connector MPO Applicable cable diameter { : Illuminating ¯ : OFF œ : Flashing Color 8.EMGS2+ 7.EMGS2- CR1 (Note 4) FG Description Monitoring LED LED 10.EMGS1+ MSTBA2.5/5-G-5.08AU Signal Name (Color) DA (BL) DB (WT) DG (YW) SLD Pin No. ¯ 20B BR-3 (1B) BK-2 (20A) Master Unit Terminal Resistance Description Turns on when communication is started, and turns OFF when communication is disconnected for the specified time Data reception error Communication Setting Error (Station Number Setting/ Baud rate setting, etc.) The station No. and baud rate set values are changed from ones set at the time of reset cancellation (0.4 sec flashing) Communication in normal condition Slave Devices Terminal Resistance Shield (SLD) No treatment conducted A 1A YW (DG) BL (DA) { : Illuminating ¯ : OFF œ : Flashing LED Color RUN ERR Green Orange Lamp condition { { Terminal Resistance is required to be mounted on the terminal. The terminal resistor differs depending on the type of the dedicated cable for CC-Link. • Cable FANC-SBH···130Ω1/2W (High Performance Cable dedicated for CC-Link) • Cable FANC-SB······110Ω1/2W (CC-Link Dedicated Cable) WT (DB) Flat Cable (20-core) × 2 Monitoring LED MSEL 1B Half Pitch MIL Socket HIF6-40D-1.27R (Hirose Electric) BR-1 (1A) Enclosed in standard package Manufactured by PHOENIX CONTACT Description Initialization complete, In the normal operation PIO Power Voltage (24V DC) Drop Error Class D grounding (Formerly Class-III grounding: Grounding resistance at 100W or less) SLD and FG are internally connected. PROFIBUS-DP Starting Procedures [Refer to the instruction manuals for PROFIBUS-DP] 1 5 Connector Name Cable Side Controller Side 6 When using this product for the first time, make sure to avoid mistakes and incorrect wiring by referring to the procedure below. PROFIBUS-DP Connector 9-pin D-sub Connector (Male) 9-pin D-sub Connector (Female) Please prepare separately No → Check of Packed Items Are there all the delivered items? Contact us or our distributor. ↓Yes 9 Pin No. Signal Name 1 2 3 4 5 6 7 8 9 NC NC B-Line RTS GND +5V NC A-Line NC Disconnected Disconnected Communication Line B (RS485) Request for Sending Signal GND (Insulation) +5V Output (Insulation) Disconnected Communication Line A (RS485) Disconnected Monitoring LED LED Green Orange Green NS Orange ↓ 6 1 9 5 ↓ Signal Name TD+ Data sending + TD- Data sending - 3 RD+ Data receiving + 4 5 - Disconnected Disconnected 6 RD- Data receiving - 7 - Disconnected 8 - Disconnected For EtherNet cable, use a straight STP cable that possesses the performance of Category 5e or more. { : Illuminating ¯ : OFF œ : Flashing Description Orange { œ In normal operation and under control of scanner (master) Setting of construction information incomplete, or scanner (master) in idling condition Fatal malfunction (exception condition or critical error Light malfunction possible to recover Green/ Orange ¯ Power OFF { œ { œ Online (Connection established on one or more) Online (connection not established) Critical error such as IP address duplication Timeout in connection on one or more ¯ Power OFF, IP address not established œ Orange Green/ Orange Check the emergency stop circuit. Operation check on actuator Check by JOG operation that operation of the full stroke can be performed with no abnormality. Caution y To ensure safety, it is recommended that safety speed be enabled during initial movements. y When putting the brake release switch to “RLS” side on a robot installed vertically, pay attention not to pinch fingers or damage a hand by the actuator dropped by its own weight. Head Office: 577-1 Obane Shimizu-KU Shizuoka City Shizuoka 424-0103, Japan TEL +81-54-364-5105 FAX +81-54-364-2589 website: www.iai-robot.co.jp/ Now, preparation for operation is complete. Technical Support available in USA, Europe and China zTroubleshooting Lamp condition Green NS Applicable cable diameter Description 2 { No → ↓Yes 1 Green pendant and check the content of the alarm to have the right treatment. ↓Yes Monitoring LED MS No → If an alarm is generated, connect the PC or teaching Safety Circuit Check Does the emergency stop circuit (drive cutoff circuit) work properly and turn the servo OFF? EtherNet/IP Connector 8P8C Modular Plug 8P8C Modular Jack Color ↓Yes ! Check Item Confirm that “Servo-ON: SV” is turned on in a teaching tool such as PC. [Refer to the instruction manuals for EtherNet/IP] LED alarm and have an appropriate treatment. y It is necessary to supply I/O power for PIO Type. When I/O is not to be used, set I/O Parameter No. 10 = 0 y Connect to the upper master for Fieldbus Type (Set I/O Parameter No. 18 = 0 when not connecting to master) Please perform this process with the actuator away from the mechanical end or interfering subjects as much as possible. Put the actuator away if it interferes with surroundings. It may generate an alarm if the actuator hit the mechanical end or interfering subjects when the servo is turned ON. The slider may get slightly dropped by self-weight if servo ON and OFF is repeatedly performed at the same position. Be careful not to pinch the hand or damage the work. EtherNet/IP Front View of Connector on Controller side No → Connect the teaching tool such as PC to confirm the content of Caution Green A line (Negative side) Pin No. Check Item Is the panel window showing “ ”? Servo ON Turn the servo ON with the operation on the teaching tool such as PC. Shield 8 Power Supply and Alarm Check Connect a teaching tool such as PC, turn the operation mode setting switch to “MANU” side and turn the power ON for unit. ↓ Description Initial condition Initial condition (with network check event) Exception error Online (Communication in normal condition) Online (Cleared) Error occurrence Cable 1 • Has the noise countermeasure been taken? ↓ Red B line (Positive side) Connector Name Cable Side Controller Side Installation and Wiring [Refer to Chapter 1 and 2.1] Perform the installation of and wiring for the actuator and controller. Point Check Item • Is frame ground (FG) and protection earthing (PE) connected? { : Illuminating ¯ : OFF œ : Flashing Lamp condition { ☆ { { ☆ { Color MS Applicable cable diameter Description The following alarm displays are frequently generated at the start-up operation. Deal with each of them referring to the following table. Status display Status contents During Emergency-stop Deadman switch OFF Cause and Remedy It is not an alarm. • It is caused when the emergency stop button is not cleared on the front panel. Clear it. • It is generated when the emergency stop switch in the teaching pendant or the personal computer application software is not cancelled. In such case, cancel it. • It is generated when the personal computer cable is not connected to the emergency stop box. It is not an alarm. • It generated when the AUTO/MANU switch has been set to “MANU” and the personal computer or the teaching pendant is not connected. Connect the personal computer or the teaching pendant or set the AUTO/MANU switch to “AUTO”. • When the actuator is to be started up, hold the deadman switch on the teaching pendant to turn it on. AC Power Interruption It is generated when the power voltage is not supplied. Check the power supply. Momentary Power Failure Power Voltage Drop 24V I/O Error It is generated when the +24V power for I/O is not supplied. Check the power supply. (Procedure for starting up I/O 24V power unit without connection) Set both the I/O parameter No. 10 to “0”. In this case, the I/O connection is invalid. Field Bus Error It is generated when the field bus link connection is not established. Check the link cable connection, I/O parameter and PLC parameter settings. (How to start up the controller without connecting the field bus) Set both the I/O parameter No. 18 to “0”. Head Office: 2690 W. 237th Street, Torrance, CA 90505 TEL (310) 891-6015 FAX (310) 891-0815 Chicago Office: 110 East State Parkway, Schaumburg, IL 60173 TEL(847) 908-1400 FAX (847) 908-1399 Atlanta Office: 1220 Kennestone Circle, Suite 108, Marietta, GA 30066 TEL (678) 354-9470 FAX (678) 354-9471 website: www.intelligentactuator.com Ober der Röth 4, D-65824 Schwalbach am Taunus, Germany TEL 06196-88950 FAX 06196-889524 SHANGHAI JIAHUA BUSINESS CENTER A8-303, 808, Hongqiao Rd. Shanghai 200030, China TEL 021-6448-4753 FAX 021-6448-3992 website: www.iai-robot.com 825 PhairojKijja Tower 12th Floor, Bangna-Trad RD., Bangna, Bangna, Bangkok 10260, Thailand TEL +66-2-361-4458 FAX +66-2-361-4456 Manual No.: ME0337-3A