Preview only show first 10 pages with watermark. For full document please download

Fisher Scientific Fs2 Series Biological Safety Cabinets

   EMBED


Share

Transcript

Fisher Scientific FS2 Series Biological Safety Cabinets CLASS II Type A/B3 • NSF49 approved, Type A2 airflow design for excellent user, product and environmental protection • Suitable for use in Biosafety Levels 1, 2, and 3 • Large work volume with stainless steel interior liner • Digital touch tone control panel with on-board monitoring and diagnostics • 3 year Manufacturer’s warranty against defects in material or workmanship One place One standard One call Front Elevation Side View Class II, Type A2 (Recirculating) models come complete with fluorescent lights, UV light, one duplex electrical outlet, digital motor controller, static pressure monitor and one gas turret located on the left hand side wall. Console models include base support stand. Model Cat. No. Type Hand Opening Dim. A Work Volume WxDxH Work Tray 4 ft Console 36-100-4616 A/B3 10” (254mm) 52.5” (1334mm) 46.5” x 27.5” x 28” (1181mm) x (699mm) x (710mm) 18” x 46.5” (457mm) x (1181mm) Weights Actual Shipping 420 Lbs. 600 Lbs. (191Kg.) (272Kg.) 4 ft Bench Top 36-100-4618 A/B3 10” (254mm) 52.5” (1334mm) 46.5” x 27.5” x 28” (1181mm) x (699mm) x (710mm) 18” x 46.5” (457mm) x (1181mm) 420 Lbs. 600 Lbs. (191Kg.) (272Kg.) 6 ft Console 36-100-4617 A/B3 10” (254mm) 76.5” (1943mm) 70.5” x 27.5” x 28” (1791mm) x (699mm) x (710mm) 18” x 70.5” (457mm) x (1791mm) 540 Lbs. 725 Lbs. (245Kg.) (329Kg.) 6 ft Bench Top 36-100-4619 A/B3 10” (254mm) 76.5” (1943mm) 70.5” x 27.5” x 28” (1791mm) x (699mm) x (710mm) 18” x 70.5” (457mm) x (1791mm) 540 Lbs. 725 Lbs. (245Kg.) (329Kg.) Class II, Type A2 (Exhausted) models are also available Technical Specifications Air System Classification CLASS II Type A/B3 as per NSF 49 Standard Motor 1/2 hp direct drive capacitor start type Design Negative pressure plenum Standard Filters Exhaust and Supply HEPA filters are rated 99.99% efficient at 0.3 microns and larger Electrical Line Feed 115 V, 12 A, 60 Hz, also available in 220V/50Hz models Control Panel Fully electronic type featuring soft touch keypad with on/off indicators on all switches, dual processor controls, LVS (Low Voltage Stabilization) circuitry and calibrated linear static pressure display (LED’s) complete with high/low audio and visual alarm feature and mute function. In addition, the B3 unit has an additional electronic system c/w audio/visual and mute functions that monitors the static pressure in the exhaust ductwork. General Noise Level Less than 62 dBA Base Frame The knock down base frame is 30” (standard) or 36” (optional) Certification NSF 49 certified, CSA/NRTL Optional Equipment Cat. No. Description 36-100-4729 Additional duplex outlet 36-100-4730 Additional gas turret 36-100-4731 Additional air turret* 36-100-4732 Additional vacuum turret** 36-100-4733 I.V. bar for 4’ models 36-100-4734 I.V. bar for 6’ models 36-100-4735 4’ knock down base frame, 30” high 36-100-4736 6’ knock down base frame, 30” high 36-100-4737 4’ knock down base frame, 36” high 36-100-4738 6’ knock down base frame, 36” high 36-100-4741 4’ hard connection transition canopy 36-100-4742 6’ hard connection transition canopy 36-100-4743 4’ thimble connection transition canopy 36-100-4744 6’ thimble connection transition canopy * Unless otherwise stated additional air turrets will be located on the left hand side of hood ** Unless otherwise stated additional vacuum turrets will be located on the right hand side of hood.