Preview only show first 10 pages with watermark. For full document please download

Fit 15-4722-54-m1 - Leds-c4

   EMBED


Share

Transcript

FIT 15-4722-54-M1 IN Description Square LED panel prepared for all kinds of ceilings and installations (recessed by direct replacement of panels in Armstrong ceilings, or recessed, suspended or on the surface with installation kits). Made in anodised extruded aluminium and PMMA diffuser. It incorporates an internal system to distribute the light, which guarantees its uniformity. The photograph may not match the reference exactly. Please read the product description to identify the finish. Download photometric file .ldt /.ies TECHNICAL CHARACTERISTICS Type: Ceiling fixture IP Protection degrees: IP40 Light source 1: Bulb specified at the product label 600 x LED max. 52W Neutral white - 4000K (N) 0.56 lm CRI 70 Angle of the optics / Reflector: 120º Voltage / Frequency: max. 1400mA Warranty: 2 Option to extend the guarantee: 5 Units per box: 4 Net Weight (Kg): 0.000 Click on image to download energy label MATERIALS / FINISHES Structure material: Aluminium Diffuser material: Methacrylate Structure finish: Diffuser finish: Anodized White GEAR This item requires gear. It is not included. LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt. (+34) 973 468 100 [email protected] www.leds-c4.com Accessoris 71-4722-N3-00 Surface kit ceiling light (595 x 595 mm.), Grey Structure material: Steel Structure finish: Grey IP20 71-0558-54-00 Recessed kit ceiling light (595 x 595 mm.), Anodized aluminium Structure material: Anodized aluminium IP54 71-4723-N3-00 Suspension kit ceiling light (595 x 595 mm.), Grey Structure material: Steel Structure finish: Grey LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt. (+34) 973 468 100 [email protected] www.leds-c4.com Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency 100.00% Coordinate system CG Total Flux Maximum value 1657.26 cd Position C=0.00 G=0.00 Double Symmetrical 595 mm 548 mm Width Width Length Length Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90° 0.300304 m2 0.000000 m2 0.000000 m2 Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76° 0.000000 m2 0.000000 m2 0.072650 m2 Symmetry Type Measurement Distance Double Symmetrical 0.00 Maximum Gamma Angle Measurement Flux 90 4704.13 lm Operator Temperature Humidity Notes Asselum T2 25.00 °C 60.00 % Source voltage Source current Photocell Code 15-4721-54-M1 C.I.E. F UTE Height Height 4704.13 lm Rectangular Luminaire Rectangular Luminous Area Line Eulumdat 595 mm 548 mm 15-4721-54-M1 1 Luminaire Lamps Name 15-4721-54-M1 - 40.00 W 48 79 96 100 100 1.00 E D DIN 5040 B NBN 12 mm 0 mm Flux [lm] 4704.13 Pow. [W] Q.ty 40.00 1 A30 BZ 4 595mm x 595mm 90 Gamma Angles 180° 120° 0 400 105° 180 105° 270 90° 90° C Halfplanes 180.0 0.0 270.0 90.0 400 75° 75° 800 60° 60° 1200 ULOR 0.00 % DLOR 100.00 % RN 45° 45° 1600 0.00 % cd 2000 30° LITESTAR (c)OxyTech Srl www.oxytech.it 15° 0° 15° 30° Page 1 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 595mm x 595mm 15-4721-54-M1 1 4704.13 lm C Halfplanes 180.0 0.0 270.0 90.0 90 0 180 270 Gamma Angles 180° 120° 400 105° 105° 90° 90° 400 75° 75° 800 60° 60° 1200 45° 45° 1600 cd 2000 30° LITESTAR (c)OxyTech Srl www.oxytech.it 15° 0° 15° 30° Page 2 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 15-4721-54-M1 1 4704.13 lm Width at 50.00 % of Max Intensity H[m] OA OB OA OB OC OD 1.00 1.48 1.48 2.00 2.96 2.96 0 1657.26 1657.26 1657.26 1657.26 3.00 4.43 4.43 5 1650.29 1650.29 1650.38 1650.38 4.00 5.91 5.91 15 1599.84 1599.84 1599.81 1599.81 5.00 7.39 7.39 H[m] OC OD 1.00 1.47 1.47 Luminous Intensities [ cd] 25 35 45 1490.27 1319.27 1098.20 1490.27 1319.27 1098.20 1489.55 1320.72 1099.94 1489.55 1320.72 1099.94 Alpha=55.9°+55.9° G=0.0° [m] 1.00 2.00 3.00 4.00 5.00 2.00 2.95 2.95 55 854.77 854.77 853.14 853.14 3.00 4.42 4.42 65 572.20 572.20 570.69 570.69 O 5.00 7.37 7.37 75 299.15 299.15 297.52 297.52 85 52.23 52.23 51.42 51.42 Beta=55.9°+55.9° Max lux 1657 414 184 104 66 C B 4.00 5.90 5.90 Med lux 412 103 46 26 16 A D LITESTAR H[m] D[m] Max lux 1.00 2.96 1657 412 2.00 5.91 414 103 3.00 8.87 184 46 4.00 11.83 104 26 5.00 14.78 66 16 H[m] D[m] Max lux 1.00 2.95 1657 412 2.00 5.90 414 103 3.00 8.85 184 46 4.00 11.80 104 26 5.00 14.75 66 16 (c)OxyTech Srl www.oxytech.it Med Alpha=55.9°+55.9° lux Med Beta=55.9°+55.9° lux G=0.0 G=0.0 Page 3 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 15-4721-54-M1 1 4704.13 lm Isolux (Floor) Luminaire position X=0.00m Y=0.00m Z=3.00m -2.0m 2.0m -1.5m -1.0m -0.5m 0.0m 0.5m 80 90 1.0m 100 100 90 1.5m 110 1.5m 60 70 2.0m 50 80 110 60 80 70 90 80 120 130 120 140 1.0m 80 150 130 100 0 160 8 140 0.5m 0 110 170 160 90 110 130 0 0.0m 150 150 120 170 100 120 90 140 160 -0.5m 0 160 130 170 110 100 140 140 90 -1.0m 150 110 0 120 80 120 130 80 100 90 -1.5m0 110 70 100 C90 60 0 -2.0m 70 C0 LITESTAR V0H+ 80 (c)OxyTech Srl www.oxytech.it 90 lux 80 H0V- Page 4 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% 0.0° 90.0° 45° 5172 5180 50° 5116 5115 55° 4962 4953 60° 4744 4728 CG Average Luminance [cd/m²] 65° 70° 75° 4509 4310 3849 4497 4286 3828 80° 3164 3127 85° 1996 1965 15-4721-54-M1 1 4704.13 lm ----- Flush mounted or longitudinal view Illumination(lx) A A B 1 2000 1000 750 500 2000 1500 1000 C <300 750 2000 D 2 E 3 1.15 500 <300 1.5 1000 500 <300 2000 1000 500 <300 2000 1000 500 1.85 2.2 <300 2.55 85º 8 A 5 4 75º 3 65º a/hs Dark Limit 2 55º 45º 100 2 3 4 Longitudinal LITESTAR (c)OxyTech Srl www.oxytech.it 5 6 8 1000 2 3 4 5 6 8 10000 2 3 4 cd/m2 Transversal Page 5 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 595mm x 595mm 15-4721-54-M1 1 4704.13 lm C Halfplanes 90 180.0 0.0 270.0 90.0 0 180 270 2000 cd 1750 1500 1250 1000 750 500 250 0 LITESTAR -180° -120° (c)OxyTech Srl www.oxytech.it -60° 0° 60° 120° 180° Page 6 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 15-4721-54-M1 1 4704.13 lm UGR S = 0.250 Reflectancies Ceiling/Cavity Walls WorkingPlane 0.7 0.5 0.2 RoomDimensions x=2H y=2H x=2H y=3H x=2H y=4H x=2H y=6H x=2H y=8H x=2H y=12H x=4H y=2H x=4H y=3H x=4H y=4H x=4H y=6H x=4H y=8H x=4H y=12H x=8H y=4H x=8H y=6H x=8H y=8H x=8H y=12H x=12H y=4H x=12H y=6H x=12H y=8H ViewedCrosswise 18.0 19.3 19.6 20.8 20.2 21.4 20.6 21.7 20.7 21.7 20.7 21.7 18.8 19.9 20.6 21.6 21.3 22.1 21.8 22.5 21.9 22.6 22.0 22.6 21.6 22.3 22.3 22.8 22.5 22.9 22.5 23.0 21.6 22.2 22.3 22.8 22.5 22.9 LITESTAR 0.7 0.3 0.2 (c)OxyTech Srl www.oxytech.it 0.5 0.5 0.2 0.5 0.3 0.2 0.3 0.3 0.2 0.7 0.5 0.2 0.7 0.3 0.2 18.3 20.0 20.6 21.0 21.1 21.1 19.1 21.0 21.7 22.2 22.4 22.5 22.0 22.7 22.9 23.0 22.1 22.8 23.0 19.6 21.1 21.6 21.9 22.0 22.0 20.2 21.9 22.5 22.9 23.0 23.0 22.7 23.2 23.4 23.4 22.7 23.2 23.4 19.8 21.3 21.9 22.3 22.3 22.4 20.5 22.2 22.8 23.2 23.4 23.4 23.0 23.6 23.8 23.9 23.1 23.7 23.8 ViewedEndwise 18.0 19.3 19.6 20.8 20.2 21.3 20.6 21.6 20.7 21.7 20.7 21.7 18.8 19.9 20.5 21.5 21.2 22.1 21.7 22.5 21.9 22.6 22.0 22.6 21.6 22.2 22.2 22.7 22.4 22.9 22.5 22.9 21.6 22.2 22.2 22.7 22.4 22.9 0.5 0.5 0.2 0.5 0.3 0.2 0.3 0.3 0.2 18.3 19.9 20.5 20.9 21.1 21.1 19.1 20.9 21.6 22.2 22.3 22.4 22.0 22.6 22.9 23.0 22.0 22.7 22.9 19.5 21.1 21.6 21.9 22.0 22.0 20.2 21.8 22.4 22.9 23.0 23.0 22.6 23.2 23.3 23.3 22.6 23.2 23.3 19.8 21.3 21.9 22.3 22.3 22.4 20.5 22.2 22.8 23.2 23.4 23.4 23.0 23.6 23.8 23.9 23.1 23.7 23.8 Page 7 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 15-4721-54-M1 1 4704.13 lm Total Flux=4704.13 Luminaire Flux=4704.12 RI DRR RC 0.60 0.31 5 Y° ZF(Y) 0.80 0.39 5 10 33 20 129 30 275 1.00 0.47 5 1.25 0.54 5 40 451 50 633 60 795 1.50 0.60 5 2.00 0.69 5 2.50 0.74 5 3.00 0.78 5 Zonal Flux per 1000 Lumen 70 80 90 100 110 917 984 1000 1000 1000 120 1000 4.00 0.83 5 130 1000 140 1000 5.00 0.86 4 150 1000 10.00 0.93 4 160 1000 170 1000 20.00 0.97 4 180 1000 CIE Flux Codes 48 79 96 100 100 C.I.E. D DIN 5040 F UTE B NBN RN BLF 100% 5/5/5/5/5/5/5/5/5/4/4/4 A30 1.00 E BZ 4 0.00000 % 1.0 99.99985 % 0.00000 % 99.99985 % 0.00000 % 100.00000 % 0.00000 % ZF 75% 50% 25% 0% 0 LITESTAR LOR ULOR DLOR UFF DFF FFR Y 30 60 90 120 (c)OxyTech Srl www.oxytech.it 150 Gamma ° 0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180° Flux 0.00 8.41 24.95 40.74 55.16 67.75 78.10 85.61 90.41 91.69 89.79 85.28 76.97 66.56 55.18 41.20 26.37 12.67 3.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Zonal Flux Sum lm 0.00 8.41 33.36 74.10 129.26 197.01 275.11 360.72 451.13 542.82 632.61 717.89 794.86 861.43 916.61 957.80 984.17 996.84 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 Flux [%] 0.00% 0.84 % 2.50 % 4.07 % 5.52 % 6.77 % 7.81 % 8.56 % 9.04 % 9.17 % 8.98 % 8.53 % 7.70 % 6.66 % 5.52 % 4.12 % 2.64 % 1.27 % 0.32 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % Sum [%] 0.00 % 0.84 % 3.34 % 7.41 % 12.93 % 19.70 % 27.51 % 36.07 % 45.11 % 54.28 % 63.26 % 71.79 % 79.49 % 86.14 % 91.66 % 95.78 % 98.42 % 99.68 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 180 Page 8 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG Pavement Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano 0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -55 -60 -65 -70 -75 -80 -85 -90 15-4721-54-M1 1 4704.13 lm Road 0.00% 4.67% 9.30% 13.86% 18.29% 22.56% 26.64% 30.46% 34.02% 37.26% 40.17% 42.72% 44.88% 46.66% 48.06% 49.05% 49.67% 49.94% 50.00% Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Tilting Angle = 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 0.00% 4.67% 9.30% 13.86% 18.29% 22.56% 26.64% 30.46% 34.02% 37.26% 40.17% 42.72% 44.88% 46.66% 48.06% 49.05% 49.67% 49.94% 50.00% DLOR = 100.00% Pavement Road 90% 50.00% 50.00% 80% 70% C270 C90 60% 50% 40% 30% 20% 10% -90 -75 Spread -60 -45 -30 -15 0 15 30 45 60 75 90 24.8° Narrow DLOR Throw 12.5° Short ULOR SLI (glare) 6.2 Tight Efficiency CIE Cutoff Semi-Cutoff - Max: C=0.0° Gamma=0.0° RN IESNA Cutoff Cutoff Luminous Intensity Class G5 DIN5044 KB2 Glare Index D6 LITESTAR (c)OxyTech Srl www.oxytech.it IESNA Type V Very Short Quadrilateral Symmetry 99.99985 % 0.00000 % 99.99985 % 0.00000 % Page 9 Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014 Lamp Code Number Position Efficiency Coordinate system Total Flux 100.00% CG 15-4721-54-M1 1 4704.13 lm US ROAD STANDARDS % Lamp lm Uplight 180° 26.0% V. Short 1MH 19.5% 50.0% Short 13.0% 20.0 2.25MH 6.5% 100° 100° 90° 90° 80° 80° 60° Medium 20.0% 3.75MH 60° 30° 30° 0° Back Front Long Type I Type II Type III Type IV 6MH 1MH 1MH 1.75MH 2.75MH Pavement Road Luminaire Classification System (LCS) LCS Zone Lumens %Lamp %Lum FL 0° -- 30° 647.7 lm 13.8 % 13.8 % FM 30° -- 60° 1224.1 lm 26.0 % 26.0 % FH 60° -- 80° 445.3 lm 9.5 % 9.5 % FVH 80° -- 90° 35.0 lm 0.7 % 0.7 % BL 0° -- 30° 647.7 lm 13.8 % 13.8 % BM 30° -- 60° 1224.1 lm 26.0 % 26.0 % BH 60° -- 80° 445.3 lm 9.5 % 9.5 % BVH 80° -- 90° 35.0 lm 0.7 % 0.7 % UL 90° -- 100° 0.0 lm 0.0 % 0.0 % UH 100° -- 180° 0.0 lm 0.0 % 0.0 % 4704.1 lm 100.0 % 100.0 % TOTALS BUG B2 U0 G1 LITESTAR (c)OxyTech Srl www.oxytech.it Type V Very Short Quadrilateral Symmetry Page 10