Transcript
FIT 15-4722-54-M1
IN Description
Square LED panel prepared for all kinds of ceilings and installations (recessed by direct replacement of panels in Armstrong ceilings, or recessed, suspended or on the surface with installation kits). Made in anodised extruded aluminium and PMMA diffuser. It incorporates an internal system to distribute the light, which guarantees its uniformity. The photograph may not match the reference exactly. Please read the product description to identify the finish.
Download photometric file .ldt /.ies
TECHNICAL CHARACTERISTICS Type:
Ceiling fixture
IP Protection degrees:
IP40
Light source 1: Bulb specified at the product label
600 x LED max. 52W Neutral white - 4000K (N) 0.56 lm CRI 70
Angle of the optics / Reflector:
120º
Voltage / Frequency:
max. 1400mA
Warranty:
2
Option to extend the guarantee:
5
Units per box:
4
Net Weight (Kg):
0.000
Click on image to download energy label
MATERIALS / FINISHES Structure material: Aluminium
Diffuser material: Methacrylate
Structure finish:
Diffuser finish:
Anodized
White
GEAR This item requires gear. It is not included.
LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt.
(+34) 973 468 100
[email protected] www.leds-c4.com
Accessoris 71-4722-N3-00 Surface kit ceiling light (595 x 595 mm.), Grey Structure material:
Steel
Structure finish:
Grey
IP20 71-0558-54-00 Recessed kit ceiling light (595 x 595 mm.), Anodized aluminium Structure material:
Anodized aluminium
IP54 71-4723-N3-00 Suspension kit ceiling light (595 x 595 mm.), Grey Structure material:
Steel
Structure finish:
Grey
LEDS-C4 reserves the right to make the necessary technical changes they deem adequate, in order to improve the features of the product. Please consult the sales team to clarify any doubt.
(+34) 973 468 100
[email protected] www.leds-c4.com
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
100.00%
Coordinate system
CG
Total Flux
Maximum value
1657.26 cd
Position
C=0.00 G=0.00
Double Symmetrical
595 mm 548 mm
Width Width
Length Length
Horizontal Luminous Area Emitting area on Plane 0° Emitting area on Plane 90°
0.300304 m2 0.000000 m2 0.000000 m2
Emitting area on Plane 180° Emitting area on Plane 270° Glare area at 76°
0.000000 m2 0.000000 m2 0.072650 m2
Symmetry Type Measurement Distance
Double Symmetrical 0.00
Maximum Gamma Angle Measurement Flux
90 4704.13 lm
Operator Temperature Humidity Notes
Asselum T2 25.00 °C 60.00 %
Source voltage Source current Photocell
Code 15-4721-54-M1
C.I.E. F UTE
Height Height
4704.13 lm
Rectangular Luminaire Rectangular Luminous Area
Line Eulumdat
595 mm 548 mm
15-4721-54-M1 1
Luminaire Lamps Name 15-4721-54-M1 - 40.00 W
48 79 96 100 100 1.00 E
D DIN 5040 B NBN
12 mm 0 mm
Flux [lm] 4704.13
Pow. [W] Q.ty 40.00 1
A30 BZ 4
595mm x 595mm 90
Gamma Angles
180°
120°
0 400
105°
180
105°
270 90°
90°
C Halfplanes 180.0
0.0
270.0
90.0
400
75°
75°
800 60°
60°
1200 ULOR
0.00 %
DLOR
100.00 %
RN
45°
45° 1600
0.00 %
cd
2000 30°
LITESTAR
(c)OxyTech Srl www.oxytech.it
15°
0°
15°
30°
Page 1
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
595mm x 595mm
15-4721-54-M1 1 4704.13 lm
C Halfplanes 180.0
0.0
270.0
90.0
90 0 180 270
Gamma Angles
180°
120°
400
105°
105°
90°
90°
400
75°
75°
800 60°
60°
1200
45°
45° 1600
cd
2000 30°
LITESTAR
(c)OxyTech Srl www.oxytech.it
15°
0°
15°
30°
Page 2
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
15-4721-54-M1 1 4704.13 lm
Width at 50.00 % of Max Intensity H[m] OA OB
OA OB OC OD
1.00 1.48 1.48
2.00 2.96 2.96
0 1657.26 1657.26 1657.26 1657.26
3.00 4.43 4.43
5 1650.29 1650.29 1650.38 1650.38
4.00 5.91 5.91
15 1599.84 1599.84 1599.81 1599.81
5.00 7.39 7.39
H[m] OC OD
1.00 1.47 1.47
Luminous Intensities [ cd] 25 35 45 1490.27 1319.27 1098.20 1490.27 1319.27 1098.20 1489.55 1320.72 1099.94 1489.55 1320.72 1099.94
Alpha=55.9°+55.9°
G=0.0°
[m] 1.00 2.00 3.00 4.00 5.00
2.00 2.95 2.95
55 854.77 854.77 853.14 853.14
3.00 4.42 4.42
65 572.20 572.20 570.69 570.69
O
5.00 7.37 7.37
75 299.15 299.15 297.52 297.52
85 52.23 52.23 51.42 51.42
Beta=55.9°+55.9° Max lux 1657 414 184 104 66
C B
4.00 5.90 5.90
Med lux 412 103 46 26 16
A
D
LITESTAR
H[m]
D[m]
Max lux
1.00
2.96
1657
412
2.00
5.91
414
103
3.00
8.87
184
46
4.00
11.83
104
26
5.00
14.78
66
16
H[m]
D[m]
Max lux
1.00
2.95
1657
412
2.00
5.90
414
103
3.00
8.85
184
46
4.00
11.80
104
26
5.00
14.75
66
16
(c)OxyTech Srl www.oxytech.it
Med Alpha=55.9°+55.9° lux
Med Beta=55.9°+55.9° lux
G=0.0
G=0.0
Page 3
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
15-4721-54-M1 1 4704.13 lm
Isolux (Floor) Luminaire position X=0.00m Y=0.00m Z=3.00m
-2.0m 2.0m
-1.5m
-1.0m
-0.5m
0.0m
0.5m
80
90
1.0m
100 100
90
1.5m
110
1.5m 60
70
2.0m 50
80 110
60 80 70
90 80
120
130
120
140 1.0m
80 150
130
100
0 160
8 140
0.5m 0
110
170
160
90
110 130
0 0.0m
150
150 120
170
100 120
90
140
160
-0.5m 0
160 130
170 110
100 140
140
90
-1.0m
150 110
0
120 80
120
130
80 100
90
-1.5m0
110
70
100 C90 60
0 -2.0m
70
C0
LITESTAR
V0H+
80
(c)OxyTech Srl www.oxytech.it
90
lux
80 H0V-
Page 4
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
0.0° 90.0°
45° 5172 5180
50° 5116 5115
55° 4962 4953
60° 4744 4728
CG
Average Luminance [cd/m²] 65° 70° 75° 4509 4310 3849 4497 4286 3828
80° 3164 3127
85° 1996 1965
15-4721-54-M1 1 4704.13 lm
-----
Flush mounted or longitudinal view Illumination(lx) A
A
B
1
2000
1000
750
500
2000
1500
1000
C
<300 750
2000
D
2
E
3
1.15
500
<300
1.5
1000
500
<300
2000
1000
500
<300
2000
1000
500
1.85 2.2 <300
2.55
85º 8 A
5 4
75º
3
65º
a/hs
Dark Limit
2
55º
45º 100
2
3
4
Longitudinal
LITESTAR
(c)OxyTech Srl www.oxytech.it
5
6
8 1000
2
3
4
5
6
8 10000
2
3
4 cd/m2
Transversal
Page 5
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
595mm x 595mm
15-4721-54-M1 1 4704.13 lm
C Halfplanes
90
180.0
0.0
270.0
90.0
0
180 270
2000
cd
1750
1500
1250
1000
750
500
250
0
LITESTAR
-180°
-120°
(c)OxyTech Srl www.oxytech.it
-60°
0°
60°
120°
180°
Page 6
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
15-4721-54-M1 1 4704.13 lm
UGR S = 0.250 Reflectancies Ceiling/Cavity Walls WorkingPlane
0.7 0.5 0.2
RoomDimensions x=2H y=2H x=2H y=3H x=2H y=4H x=2H y=6H x=2H y=8H x=2H y=12H x=4H y=2H x=4H y=3H x=4H y=4H x=4H y=6H x=4H y=8H x=4H y=12H x=8H y=4H x=8H y=6H x=8H y=8H x=8H y=12H x=12H y=4H x=12H y=6H x=12H y=8H
ViewedCrosswise 18.0 19.3 19.6 20.8 20.2 21.4 20.6 21.7 20.7 21.7 20.7 21.7 18.8 19.9 20.6 21.6 21.3 22.1 21.8 22.5 21.9 22.6 22.0 22.6 21.6 22.3 22.3 22.8 22.5 22.9 22.5 23.0 21.6 22.2 22.3 22.8 22.5 22.9
LITESTAR
0.7 0.3 0.2
(c)OxyTech Srl www.oxytech.it
0.5 0.5 0.2
0.5 0.3 0.2
0.3 0.3 0.2
0.7 0.5 0.2
0.7 0.3 0.2
18.3 20.0 20.6 21.0 21.1 21.1 19.1 21.0 21.7 22.2 22.4 22.5 22.0 22.7 22.9 23.0 22.1 22.8 23.0
19.6 21.1 21.6 21.9 22.0 22.0 20.2 21.9 22.5 22.9 23.0 23.0 22.7 23.2 23.4 23.4 22.7 23.2 23.4
19.8 21.3 21.9 22.3 22.3 22.4 20.5 22.2 22.8 23.2 23.4 23.4 23.0 23.6 23.8 23.9 23.1 23.7 23.8
ViewedEndwise 18.0 19.3 19.6 20.8 20.2 21.3 20.6 21.6 20.7 21.7 20.7 21.7 18.8 19.9 20.5 21.5 21.2 22.1 21.7 22.5 21.9 22.6 22.0 22.6 21.6 22.2 22.2 22.7 22.4 22.9 22.5 22.9 21.6 22.2 22.2 22.7 22.4 22.9
0.5 0.5 0.2
0.5 0.3 0.2
0.3 0.3 0.2
18.3 19.9 20.5 20.9 21.1 21.1 19.1 20.9 21.6 22.2 22.3 22.4 22.0 22.6 22.9 23.0 22.0 22.7 22.9
19.5 21.1 21.6 21.9 22.0 22.0 20.2 21.8 22.4 22.9 23.0 23.0 22.6 23.2 23.3 23.3 22.6 23.2 23.3
19.8 21.3 21.9 22.3 22.3 22.4 20.5 22.2 22.8 23.2 23.4 23.4 23.0 23.6 23.8 23.9 23.1 23.7 23.8
Page 7
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
15-4721-54-M1 1 4704.13 lm
Total Flux=4704.13 Luminaire Flux=4704.12 RI DRR RC
0.60 0.31 5
Y° ZF(Y)
0.80 0.39 5
10 33
20 129
30 275
1.00 0.47 5
1.25 0.54 5
40 451
50 633
60 795
1.50 0.60 5
2.00 0.69 5
2.50 0.74 5
3.00 0.78 5
Zonal Flux per 1000 Lumen 70 80 90 100 110 917 984 1000 1000 1000
120 1000
4.00 0.83 5
130 1000
140 1000
5.00 0.86 4
150 1000
10.00 0.93 4
160 1000
170 1000
20.00 0.97 4
180 1000
CIE Flux Codes 48 79 96 100 100 C.I.E. D DIN 5040 F UTE B NBN RN BLF
100%
5/5/5/5/5/5/5/5/5/4/4/4 A30 1.00 E BZ 4 0.00000 % 1.0
99.99985 % 0.00000 % 99.99985 % 0.00000 % 100.00000 % 0.00000 %
ZF
75%
50%
25%
0% 0
LITESTAR
LOR ULOR DLOR UFF DFF FFR
Y 30
60
90
120
(c)OxyTech Srl www.oxytech.it
150
Gamma ° 0° 5° 10° 15° 20° 25° 30° 35° 40° 45° 50° 55° 60° 65° 70° 75° 80° 85° 90° 95° 100° 105° 110° 115° 120° 125° 130° 135° 140° 145° 150° 155° 160° 165° 170° 175° 180°
Flux 0.00 8.41 24.95 40.74 55.16 67.75 78.10 85.61 90.41 91.69 89.79 85.28 76.97 66.56 55.18 41.20 26.37 12.67 3.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Zonal Flux Sum lm 0.00 8.41 33.36 74.10 129.26 197.01 275.11 360.72 451.13 542.82 632.61 717.89 794.86 861.43 916.61 957.80 984.17 996.84 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00 1000.00
Flux [%] 0.00% 0.84 % 2.50 % 4.07 % 5.52 % 6.77 % 7.81 % 8.56 % 9.04 % 9.17 % 8.98 % 8.53 % 7.70 % 6.66 % 5.52 % 4.12 % 2.64 % 1.27 % 0.32 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 % 0.00 %
Sum [%] 0.00 % 0.84 % 3.34 % 7.41 % 12.93 % 19.70 % 27.51 % 36.07 % 45.11 % 54.28 % 63.26 % 71.79 % 79.49 % 86.14 % 91.66 % 95.78 % 98.42 % 99.68 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 % 100.00 %
180
Page 8
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
Pavement Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano
0 -5 -10 -15 -20 -25 -30 -35 -40 -45 -50 -55 -60 -65 -70 -75 -80 -85 -90
15-4721-54-M1 1 4704.13 lm
Road 0.00% 4.67% 9.30% 13.86% 18.29% 22.56% 26.64% 30.46% 34.02% 37.26% 40.17% 42.72% 44.88% 46.66% 48.06% 49.05% 49.67% 49.94% 50.00%
Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano Piano
Tilting Angle = 0.0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
0.00% 4.67% 9.30% 13.86% 18.29% 22.56% 26.64% 30.46% 34.02% 37.26% 40.17% 42.72% 44.88% 46.66% 48.06% 49.05% 49.67% 49.94% 50.00%
DLOR = 100.00%
Pavement
Road
90%
50.00%
50.00% 80%
70%
C270
C90
60%
50%
40%
30%
20%
10%
-90
-75
Spread
-60
-45
-30
-15
0
15
30
45
60
75
90
24.8° Narrow
DLOR
Throw
12.5° Short
ULOR
SLI (glare)
6.2 Tight
Efficiency
CIE Cutoff
Semi-Cutoff - Max: C=0.0° Gamma=0.0°
RN
IESNA Cutoff
Cutoff
Luminous Intensity Class
G5
DIN5044
KB2
Glare Index
D6
LITESTAR
(c)OxyTech Srl www.oxytech.it
IESNA Type V
Very Short
Quadrilateral Symmetry
99.99985 % 0.00000 % 99.99985 % 0.00000 %
Page 9
Luminaire Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Line Eulumdat
Measurem. Code 15-4722-54-M1 Name Fit 1400mA 52W(led-neutral-white) Date 19-11-2014
Lamp Code Number Position
Efficiency
Coordinate system
Total Flux
100.00%
CG
15-4721-54-M1 1 4704.13 lm
US ROAD STANDARDS
% Lamp lm
Uplight 180° 26.0%
V. Short 1MH
19.5%
50.0%
Short
13.0%
20.0
2.25MH 6.5% 100°
100°
90°
90°
80°
80°
60°
Medium 20.0% 3.75MH
60°
30°
30° 0°
Back
Front
Long
Type I Type II Type III Type IV 6MH 1MH 1MH 1.75MH 2.75MH Pavement Road
Luminaire Classification System (LCS) LCS Zone
Lumens
%Lamp
%Lum
FL
0° -- 30°
647.7 lm
13.8 %
13.8 %
FM
30° -- 60°
1224.1 lm
26.0 %
26.0 %
FH
60° -- 80°
445.3 lm
9.5 %
9.5 %
FVH
80° -- 90°
35.0 lm
0.7 %
0.7 %
BL
0° -- 30°
647.7 lm
13.8 %
13.8 %
BM
30° -- 60°
1224.1 lm
26.0 %
26.0 %
BH
60° -- 80°
445.3 lm
9.5 %
9.5 %
BVH
80° -- 90°
35.0 lm
0.7 %
0.7 %
UL
90° -- 100°
0.0 lm
0.0 %
0.0 %
UH
100° -- 180°
0.0 lm
0.0 %
0.0 %
4704.1 lm
100.0 %
100.0 %
TOTALS BUG B2 U0 G1 LITESTAR
(c)OxyTech Srl www.oxytech.it
Type V Very Short
Quadrilateral Symmetry Page 10