Transcript
FM420
Fixed Mount Barcode Scanner Quick Start V1.0
Revisions Version V 1.0
Description
Date
Support as from FM420 firmware V 3.06.021 and higher.
19-10-2010
Content Getting to Start
Unpacking.......................................... E-01 Main Unit........................................... E-01 Accessories ........................................ E-02 Outline and Function ......................... E-03 Data Interface Definition ................... E-04 Specification ...................................... E-05 Distance of Field................................ E-06 Dimentions of FM420 Unit ............... E-07 Connect FM420 to the Host .............. E-08
Programming Code
Query ................................................ E-09 Factory Default .................................. E-10 Reading Mode ................................... E-11 RS232 Programming ......................... E-12 USB Programming ............................ E-15 USB HID-KBW Programming.......... E-16 Beeper ................................................ E-19 Line Feed and Carriage Return.......... E-20 1D Symbols ....................................... E-21 2D Symbols ....................................... E-26
Appendix
A. Testing Codes................................ E-28 B. Digit Code and Save ..................... E-29 C. Troubleshooting ............................ E-30
Getting to Start
请更换节标题
Unpacking
Unpack and check the main unit and accessories.In case there is any problem, please contact with your dealer.
Main Unit
» FM420
E-01
Getting to Start Accessories Accessories
» USB Cable
» RS232 Cable + Power Adapter
E-02
Getting to Start Outline and Function
Indicator
Sensor Light Illumination/Aiming Light
Lens
Note:
» The scan window must be kept clean. Improper maintenance will breach the limited warranty. » » » » »
Avoid rough objects not to damage or scratch the window. Use brush to remove the stain. Use soft cloth (cloth for glasses) to clean. Prohibit spraying towards the window. Only use clean water as a cleanser.
E-03
Getting to Start Data Interface Definition
PIN 10
PIN 1
Cable Slot
Pin 1 2 3 4 5 6 7 8 9 10
Function NC NC VCC TXD RXD NC NC GND DD+
Type P O I P IO IO
Name Null Null Power DC5V Serial Port Output,RS232 Serial Port Input,RS232 Null Null Ground USB Data Signal
E-04
Getting to Start Specification Image Capture Specifications Image Sensor
CMOS
Resolution
752*480
Interface
RS232, USB
Barcode Scan Specifications 2D
PDF417, QR Code(Model 1/2), DataMatrix(ECC200, ECC000, 050, 080, 100,140),Aztec, Maxicode, etc.
1D
Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar, Interleaved 2 of 5, ISBN, Code 93, UCC/EAN-128, GS1 Databar, etc
Symbols Precision Depth of Scan Field Print Contrast Ratio Sensitivity**
≥ 5mil 35mm-210mm ≥ 30% Roll 360°@ 0°Pitch and 0° Skew Yaw (skew) ±60°@ 0°Roll and 0° Pitch Pitch ±60°@ 0°Roll and 0° Skew
Illumination Specifications Light Source Light Intensity Electrical and Mechanical Specifications Power Consumption Voltage Working Idle Current Standby Deep Sleep Dimensions(L*W*H) Weight Environment Specifications Operating Temperature Storage Temperature Humidity Ambient Illumination Certificates FCC Part15 Class B, CE EMC Class B
LED (622 nm - 628 nm) 330 LUX (130 mm ) 2W DC 5V (4.5-5.5) 400mA 78mA 18mA 800uA 60.0 *50.0*26.0mm 70g -5℃ - +45℃ -40℃ - +60℃ 5% - 95% (non-condensing) 0 ~ 100,000 LUX
**Test Condition: Code39: 4 Bytes ; Resolution = 10mil; W:N = 3:1 ; PCS = 1.0 ; Barcode Height = 12mm; Distance = 100mm; T=23°C; Illumination= 200 LUX
E-05
Getting to Start Distance of Field
36°
35mm
Code39(10mil) 55mm
Code39(15mil)
55mm
PDF417(10mil)
60mm
0
45mm
Data Matrix(10mil) Data Matrix(15mil)
45mm
QR Code(10mil)
50
210mm 175mm
PDF417(15mil)
45mm
50mm
170mm
205mm 145mm 175mm 140mm
QR Code(15mil)
100
175mm
150
200
250
E-06
Getting to Start Dimentions of FM420 Unit
M3 machine skew
11 . 7mm 26mm 36mm 50mm
9mm 12mm
10mm
60mm
E-07
Getting to Start Connect FM420 to the Host Connecting with USB Cable
1、Insert USB Cable (RJ45 male head) into FM420 cable slot; 2、Insert USB Cable (USB male head) into Host’s (female) USB connector;
Connecting with RS232 Cable
1、Insert RS232 cable (RJ45 male head) into FM420 cable slot; 2、Insert RS232 cable (RS232 male head) into Host’s (female) RS232 connector; 3、Connect RS232 cable and the mains with power adapter;
E-08
Programming Code
请更换节标题
Code Programming ON
Query “Send Product Info”, the engine sends product information to the Host immediately.“Send Sys Info when Power ON”, the engine sends product information through RS232(only) to the Host after Power ON. Code Programming OFF
Send Product Info
Send Sys Info when Power ON
Do not Send Product Info when Power ON (Factory Default)
The system information is provided as follows: Title Firmware Ver Build Time Device ID App Ver uIMG Ver Date S/N ESN Manufacture ID Interface 1D 2D Scan Mode
Remarks Device Firmware Version Device Firmware Version Establishing Time Device Type Device Application Version Device uIMG Version Device Manufacture Date Device serial number User-defined device serial number Device Name 1 types of communication interfaces: RS232, baud rate, parity check, data bits, stop bit Indicate that reading 1D is allowed. Indicate that reading 2D is allowed. Auto Scan
E-09
Programming Code Factory Default Code Programming ON
Code Programming OFF
Load All Factory Default
Part of Factory Default Subject
Factory Default
Beep
RS232 and USB Self-adaption ,The default value is as below: RS232(Baud Rate: 9600bit/s,Parity Check:No Check,Data / Stop Bit:8 bits/1 bit); USB(HID-KBW) On
Scan Mode
Auto Mode
Interface
Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar, 1D 1D Symbols(Enable) China post 25,Interleaved 2 of 5, ISBN/ISSN, Code 93, GS1 Databar, Code 11,etc PDF417, QR Code(Model 1/2), DataMatrix (ECC200, ECC000, 2D 1D Symbols(Enable) 050, 080,100,140), Aztec, Maxicode, LP Code, etc.
E-10
Programming Code Reading Mode Code Programming ON
» Auto Mode: The ambient luminance change in front of the engine automatically initiates reading. After completion of reading, the engine goes to idle. Both luminance change and the Trigger can initiate reading when idle.
Code Programming OFF
Auto Mode (Factory Default)
E-11
Programming Code RS232 Programming Baud Rate Under RS232 connection, the engine and the Host should set communication baud rate to the same to keep normal communication. Baud rate is the bits transmitted per second (8 bits per bytes). The engine and the Host must communicate at the same baud rate. The scanner supports baud rate as the following:
Code Programming ON
Code Programming OFF
9600 (Factory Default) 1200
2400 4800
14400 19200
38400 57600
115200
E-12
Programming Code RS232 Programming Code Programming ON
Parity Check
Code Programming OFF
NO Check (Factory Default)
Odd Check Even Check
Stop Bits
1 Stop Bit (Factory Default)
2 Stop Bits
E-13
Programming Code RS232 Programming Data Bits Transmitted
Code Programming ON
Code Programming OFF
8 Data Bits (Factory Default)
6 Data Bits
7 Data Bits
5 Data Bits
E-14
Programming Code USB Programming Code Programming ON
Code Programming OFF
Select USB HID-KBW
Select USB COM Port Emulation
Select USB DataPipe
Select USB HID-POS
Note: A driver has to be installed before using USB DataPipe and USB COM Port Emulation.
E-15
Programming Code USB HID-KBW Programming Code Programming ON
Keyboard Coutry The keyboard arrangements and country codes vary in different countries. Refer country codes to the table “USB Country Keyboard Types”. Follow the steps mentioned below to program. 1.“Code Programming ON” 2.“Select Country Code” 3. Read digit codes (See “country code” and appendix for digit code) 4.“Save ” 5.“Code Programming OFF”
Code Programming OFF
Select Country Code
Country Code Country/Language U.S.(Factory Default) Belgium Brazil Canada(French) Czechoslovakia Denmark Finland(Swedish) France Germany/Austria Greece Hungary Israel(Hebrew) Italy Latin-American
Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13
Country/Language Netherlands(Dutch) Norway Poland Portugal Romania Russia Slovakia Spain Sweden Switzerland(German) Turkey F Turkey Q U.K Japan
Code 14 15 16 17 18 19 21 22 23 24 25 26 27 28 E-16
Programming Code USB HID-KBW Programming Code Programming ON
Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan programming code below to increase the delay when the Host require a slower transmission of data.
Code Programming OFF
Short Delay(Continuous keystroke) (Factory Default)
Long Delay(40ms) Medium Delay(20ms)
Caps Lock Override The case of the data is inverted regardless of the state of the Caps Lock key on the Host. Lower case and upper case are converted correspondingly.
No Caps Lock Override (Factory Default) Caps Lock Override E-17
Programming Code USB HID-KBW Programming Code Programming ON
Convert Case The Imager converts all barcode messages to the selected case.
Code Programming OFF
No Case Conversion (Factory Default)
Convert All to Lower Case
Convert All to Upper Case
E-18
Programming Code Beeper Code Programming ON
Decoding Beep
Code Programming OFF
Beep ON (Factory Default) Beep OFF
Volume
Loud (Factory Default)
Low Medium
Beep Denotation (Beeper Definitions) Beep low-higher-higher-higher 1 beep 2 beeps 3 short low-2 high 1 long low
Denotation Power ON completed successful reading of an ordinary barcode successful reading of an programming barcode reading failure Unknown Character, Virtual Keypad (USB connection)
E-19
Programming Code Line Feed and Carriage Return Need to program stop suffix and enable it supports line feed and carriage return. Program Stop Suffix Read “Program Stop Suffix”. Then program stop suffix byte(s) to end the suffix, read “Save ”. The stop suffix byte is programmed in its hex values. For Windows OS, the hex values of "line feed and carriage return” are “0X0D/0X0A”.
Code Programming ON
Code Programming OFF
Program Stop Suffix
Stop Suffix Enable and Disable
Enable Stop Suffix Disable Stop Suffix (Factory Default) Steps for Windows OS to achieve “line feed and carriage return“ 1、Read “Code Programming ON” 2、Read “Program Stop Suffix” 3、Read “0”“D”“0”“A” 4、Read “Save ” 5、Read “Code Programming OFF” 6、Read “Allow Stop Suffix” to enable above programming. A line feed will appear to the right of a barcode. E-20
Programming Code 1D Symbols Code Programming ON
All 1D Symbols
Code Programming OFF
Enable Reading All 1D
Disable Reading All 1D
Code 128
Disable Code 128
Enable Code 128 (Factory Default)
Min Message Length (default: 1) Max Message Length (default: 48) E-21
Programming Code 1D Symbols EAN-8
Code Programming ON
Code Programming OFF
Enable EAN-8 (Factory Default)
Disable EAN-8
EAN-13
Enable EAN-13 (Factory Default)
Disable EAN-13
E-22
Programming Code 1D Symbols UPC-E
Code Programming ON
Code Programming OFF
Enable UPC-E (Factory Default)
Disable UPC-E UPC-A
Enable UPC-A (Factory Default)
Disable UPC-A
E-23
Programming Code 1D Symbols Interleaved 2 of 5
Code Programming ON
Code Programming OFF
Enable Interleaved 2 of 5 (Factory Default)
Disable Interleaved 2 of 5
Min Message Length (default: 4)
Max Message Length (default: 80)
E-24
Programming Code 1D Symbols Code Programming ON
Code 39
Code Programming OFF
Enable Code 39 (Factory Default)
Disable Code 39
Min Message Length (default: 1)
Max Message Length (default: 48) GS1 Databar
Enable GS1 Databar (Factory Default) Disable GS1 Databar E-25
Programming Code 2D Symbols Code Programming ON
All 2D Symbols
Code Programming OFF
Enable Reading All 2D
Disable Reading All 2D PDF417
Enable PDF417 (Factory Default) Disable PDF417 Data Matrix
Enable Data Matrix (Factory Default) Disable Data Matrix
E-26
Programming Code 2D Symbols Code Programming ON
QR Code
Code Programming OFF
Enable QR Code (Factory Default)
Disable QR Code
Aztec
Enable Aztec Disable Aztec (Factory Default)
Maxicode
Enable Maxicode Disable Maxicode (Factory Default)
E-27
Appendix
请更换节标题
A. Testing Codes
Code 128
UCC/EAN-128
UPC-E
UPC-A
Interleaved 2 of 5
Code39
QR Code
PDF417
Aztec
Micro QR
DataMatrix
E-28
Appendix B. Digit Code and Save It is must to read save after reading digit code.
0
B 6
1
C 7
2
D 8
3
E 9
4
F A
5
Save
E-29
Appendix C. Troubleshooting
Problem
Possible Cause
Possible Solution
With RS232 communication, adapter not inserted
Insert the adapter
With RS232 communication, communication interface fails.
Connect communication port in right way
With USB or PS/2 communication, communication interface fails.
Connect communication port in right way
Engine does not send data to host computer
Engine is not connected to the host.
Check all cable to host computer.
Receive garbled with RS232
Engine and the host baud rate settings are inconsistent
Check engine and PC-side communication port baud rate settings are the same
Did not enable the barcode
Please enable it
Engine can not read the barcode by it’s firmware.
Please contact the dealer or us
Engine does not turn on
Engine does not read barcodes
E-30
Newland EMEA +31 (0) 345 87 00 33
[email protected] Newland D-A-CH +49 (0) 294 298 76758
[email protected] Newland UK +44 (0) 1442 212 020
[email protected] Newland Nordic +46 (0) 708 847 767
[email protected] Newland Ibérica +34 (0) 93 303 74 66
[email protected] Newland France +31 (0) 345 87 00 33
[email protected] Newland Middle East +31 (0) 345 87 00 33
[email protected] Newland South Africa +27 (0) 11 553 8010
[email protected] Newland Italy +39 (0) 342 056 2227
[email protected] Newland Russia +31 (0) 345 87 00 33
[email protected]