Preview only show first 10 pages with watermark. For full document please download

Fixed Mount Barcode Scanner Quick Start

   EMBED


Share

Transcript

FM420 Fixed Mount Barcode Scanner Quick Start V1.0 Revisions Version V 1.0 Description Date Support as from FM420 firmware V 3.06.021 and higher. 19-10-2010 Content Getting to Start Unpacking.......................................... E-01 Main Unit........................................... E-01 Accessories ........................................ E-02 Outline and Function ......................... E-03 Data Interface Definition ................... E-04 Specification ...................................... E-05 Distance of Field................................ E-06 Dimentions of FM420 Unit ............... E-07 Connect FM420 to the Host .............. E-08 Programming Code Query ................................................ E-09 Factory Default .................................. E-10 Reading Mode ................................... E-11 RS232 Programming ......................... E-12 USB Programming ............................ E-15 USB HID-KBW Programming.......... E-16 Beeper ................................................ E-19 Line Feed and Carriage Return.......... E-20 1D Symbols ....................................... E-21 2D Symbols ....................................... E-26 Appendix A. Testing Codes................................ E-28 B. Digit Code and Save ..................... E-29 C. Troubleshooting ............................ E-30 Getting to Start 请更换节标题 Unpacking Unpack and check the main unit and accessories.In case there is any problem, please contact with your dealer. Main Unit » FM420 E-01 Getting to Start Accessories Accessories » USB Cable » RS232 Cable + Power Adapter E-02 Getting to Start Outline and Function Indicator Sensor Light Illumination/Aiming Light Lens Note: » The scan window must be kept clean. Improper maintenance will breach the limited warranty. » » » » » Avoid rough objects not to damage or scratch the window. Use brush to remove the stain. Use soft cloth (cloth for glasses) to clean. Prohibit spraying towards the window. Only use clean water as a cleanser. E-03 Getting to Start Data Interface Definition PIN 10 PIN 1 Cable Slot Pin 1 2 3 4 5 6 7 8 9 10 Function NC NC VCC TXD RXD NC NC GND DD+ Type P O I P IO IO Name Null Null Power DC5V Serial Port Output,RS232 Serial Port Input,RS232 Null Null Ground USB Data Signal E-04 Getting to Start Specification Image Capture Specifications Image Sensor CMOS Resolution 752*480 Interface RS232, USB Barcode Scan Specifications 2D PDF417, QR Code(Model 1/2), DataMatrix(ECC200, ECC000, 050, 080, 100,140),Aztec, Maxicode, etc. 1D Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar, Interleaved 2 of 5, ISBN, Code 93, UCC/EAN-128, GS1 Databar, etc Symbols Precision Depth of Scan Field Print Contrast Ratio Sensitivity** ≥ 5mil 35mm-210mm ≥ 30% Roll 360°@ 0°Pitch and 0° Skew Yaw (skew) ±60°@ 0°Roll and 0° Pitch Pitch ±60°@ 0°Roll and 0° Skew Illumination Specifications Light Source Light Intensity Electrical and Mechanical Specifications Power Consumption Voltage Working Idle Current Standby Deep Sleep Dimensions(L*W*H) Weight Environment Specifications Operating Temperature Storage Temperature Humidity Ambient Illumination Certificates FCC Part15 Class B, CE EMC Class B LED (622 nm - 628 nm) 330 LUX (130 mm ) 2W DC 5V (4.5-5.5) 400mA 78mA 18mA 800uA 60.0 *50.0*26.0mm 70g -5℃ - +45℃ -40℃ - +60℃ 5% - 95% (non-condensing) 0 ~ 100,000 LUX **Test Condition: Code39: 4 Bytes ; Resolution = 10mil; W:N = 3:1 ; PCS = 1.0 ; Barcode Height = 12mm; Distance = 100mm; T=23°C; Illumination= 200 LUX E-05 Getting to Start Distance of Field 36° 35mm Code39(10mil) 55mm Code39(15mil) 55mm PDF417(10mil) 60mm 0 45mm Data Matrix(10mil) Data Matrix(15mil) 45mm QR Code(10mil) 50 210mm 175mm PDF417(15mil) 45mm 50mm 170mm 205mm 145mm 175mm 140mm QR Code(15mil) 100 175mm 150 200 250 E-06 Getting to Start Dimentions of FM420 Unit M3 machine skew 11 . 7mm 26mm 36mm 50mm 9mm 12mm 10mm 60mm E-07 Getting to Start Connect FM420 to the Host Connecting with USB Cable 1、Insert USB Cable (RJ45 male head) into FM420 cable slot; 2、Insert USB Cable (USB male head) into Host’s (female) USB connector; Connecting with RS232 Cable 1、Insert RS232 cable (RJ45 male head) into FM420 cable slot; 2、Insert RS232 cable (RS232 male head) into Host’s (female) RS232 connector; 3、Connect RS232 cable and the mains with power adapter; E-08 Programming Code 请更换节标题 Code Programming ON Query “Send Product Info”, the engine sends product information to the Host immediately.“Send Sys Info when Power ON”, the engine sends product information through RS232(only) to the Host after Power ON. Code Programming OFF Send Product Info Send Sys Info when Power ON Do not Send Product Info when Power ON (Factory Default) The system information is provided as follows: Title Firmware Ver Build Time Device ID App Ver uIMG Ver Date S/N ESN Manufacture ID Interface 1D 2D Scan Mode Remarks Device Firmware Version Device Firmware Version Establishing Time Device Type Device Application Version Device uIMG Version Device Manufacture Date Device serial number User-defined device serial number Device Name 1 types of communication interfaces: RS232, baud rate, parity check, data bits, stop bit Indicate that reading 1D is allowed. Indicate that reading 2D is allowed. Auto Scan E-09 Programming Code Factory Default Code Programming ON Code Programming OFF Load All Factory Default Part of Factory Default Subject Factory Default Beep RS232 and USB Self-adaption ,The default value is as below: RS232(Baud Rate: 9600bit/s,Parity Check:No Check,Data / Stop Bit:8 bits/1 bit); USB(HID-KBW) On Scan Mode Auto Mode Interface Code128, EAN-13, EAN-8, Code39, UPC-A, UPC-E, Codabar, 1D 1D Symbols(Enable) China post 25,Interleaved 2 of 5, ISBN/ISSN, Code 93, GS1 Databar, Code 11,etc PDF417, QR Code(Model 1/2), DataMatrix (ECC200, ECC000, 2D 1D Symbols(Enable) 050, 080,100,140), Aztec, Maxicode, LP Code, etc. E-10 Programming Code Reading Mode Code Programming ON » Auto Mode: The ambient luminance change in front of the engine automatically initiates reading. After completion of reading, the engine goes to idle. Both luminance change and the Trigger can initiate reading when idle. Code Programming OFF Auto Mode (Factory Default) E-11 Programming Code RS232 Programming Baud Rate Under RS232 connection, the engine and the Host should set communication baud rate to the same to keep normal communication. Baud rate is the bits transmitted per second (8 bits per bytes). The engine and the Host must communicate at the same baud rate. The scanner supports baud rate as the following: Code Programming ON Code Programming OFF 9600 (Factory Default) 1200 2400 4800 14400 19200 38400 57600 115200 E-12 Programming Code RS232 Programming Code Programming ON Parity Check Code Programming OFF NO Check (Factory Default) Odd Check Even Check Stop Bits 1 Stop Bit (Factory Default) 2 Stop Bits E-13 Programming Code RS232 Programming Data Bits Transmitted Code Programming ON Code Programming OFF 8 Data Bits (Factory Default) 6 Data Bits 7 Data Bits 5 Data Bits E-14 Programming Code USB Programming Code Programming ON Code Programming OFF Select USB HID-KBW Select USB COM Port Emulation Select USB DataPipe Select USB HID-POS Note: A driver has to be installed before using USB DataPipe and USB COM Port Emulation. E-15 Programming Code USB HID-KBW Programming Code Programming ON Keyboard Coutry The keyboard arrangements and country codes vary in different countries. Refer country codes to the table “USB Country Keyboard Types”. Follow the steps mentioned below to program. 1.“Code Programming ON” 2.“Select Country Code” 3. Read digit codes (See “country code” and appendix for digit code) 4.“Save ” 5.“Code Programming OFF” Code Programming OFF Select Country Code Country Code Country/Language U.S.(Factory Default) Belgium Brazil Canada(French) Czechoslovakia Denmark Finland(Swedish) France Germany/Austria Greece Hungary Israel(Hebrew) Italy Latin-American Code 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Country/Language Netherlands(Dutch) Norway Poland Portugal Romania Russia Slovakia Spain Sweden Switzerland(German) Turkey F Turkey Q U.K Japan Code 14 15 16 17 18 19 21 22 23 24 25 26 27 28 E-16 Programming Code USB HID-KBW Programming Code Programming ON Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan programming code below to increase the delay when the Host require a slower transmission of data. Code Programming OFF Short Delay(Continuous keystroke) (Factory Default) Long Delay(40ms) Medium Delay(20ms) Caps Lock Override The case of the data is inverted regardless of the state of the Caps Lock key on the Host. Lower case and upper case are converted correspondingly. No Caps Lock Override (Factory Default) Caps Lock Override E-17 Programming Code USB HID-KBW Programming Code Programming ON Convert Case The Imager converts all barcode messages to the selected case. Code Programming OFF No Case Conversion (Factory Default) Convert All to Lower Case Convert All to Upper Case E-18 Programming Code Beeper Code Programming ON Decoding Beep Code Programming OFF Beep ON (Factory Default) Beep OFF Volume Loud (Factory Default) Low Medium Beep Denotation (Beeper Definitions) Beep low-higher-higher-higher 1 beep 2 beeps 3 short low-2 high 1 long low Denotation Power ON completed successful reading of an ordinary barcode successful reading of an programming barcode reading failure Unknown Character, Virtual Keypad (USB connection) E-19 Programming Code Line Feed and Carriage Return Need to program stop suffix and enable it supports line feed and carriage return. Program Stop Suffix Read “Program Stop Suffix”. Then program stop suffix byte(s) to end the suffix, read “Save ”. The stop suffix byte is programmed in its hex values. For Windows OS, the hex values of "line feed and carriage return” are “0X0D/0X0A”. Code Programming ON Code Programming OFF Program Stop Suffix Stop Suffix Enable and Disable Enable Stop Suffix Disable Stop Suffix (Factory Default) Steps for Windows OS to achieve “line feed and carriage return“ 1、Read “Code Programming ON” 2、Read “Program Stop Suffix” 3、Read “0”“D”“0”“A” 4、Read “Save ” 5、Read “Code Programming OFF” 6、Read “Allow Stop Suffix” to enable above programming. A line feed will appear to the right of a barcode. E-20 Programming Code 1D Symbols Code Programming ON All 1D Symbols Code Programming OFF Enable Reading All 1D Disable Reading All 1D Code 128 Disable Code 128 Enable Code 128 (Factory Default) Min Message Length (default: 1) Max Message Length (default: 48) E-21 Programming Code 1D Symbols EAN-8 Code Programming ON Code Programming OFF Enable EAN-8 (Factory Default) Disable EAN-8 EAN-13 Enable EAN-13 (Factory Default) Disable EAN-13 E-22 Programming Code 1D Symbols UPC-E Code Programming ON Code Programming OFF Enable UPC-E (Factory Default) Disable UPC-E UPC-A Enable UPC-A (Factory Default) Disable UPC-A E-23 Programming Code 1D Symbols Interleaved 2 of 5 Code Programming ON Code Programming OFF Enable Interleaved 2 of 5 (Factory Default) Disable Interleaved 2 of 5 Min Message Length (default: 4) Max Message Length (default: 80) E-24 Programming Code 1D Symbols Code Programming ON Code 39 Code Programming OFF Enable Code 39 (Factory Default) Disable Code 39 Min Message Length (default: 1) Max Message Length (default: 48) GS1 Databar Enable GS1 Databar (Factory Default) Disable GS1 Databar E-25 Programming Code 2D Symbols Code Programming ON All 2D Symbols Code Programming OFF Enable Reading All 2D Disable Reading All 2D PDF417 Enable PDF417 (Factory Default) Disable PDF417 Data Matrix Enable Data Matrix (Factory Default) Disable Data Matrix E-26 Programming Code 2D Symbols Code Programming ON QR Code Code Programming OFF Enable QR Code (Factory Default) Disable QR Code Aztec Enable Aztec Disable Aztec (Factory Default) Maxicode Enable Maxicode Disable Maxicode (Factory Default) E-27 Appendix 请更换节标题 A. Testing Codes Code 128 UCC/EAN-128 UPC-E UPC-A Interleaved 2 of 5 Code39 QR Code PDF417 Aztec Micro QR DataMatrix E-28 Appendix B. Digit Code and Save It is must to read save after reading digit code. 0 B 6 1 C 7 2 D 8 3 E 9 4 F A 5 Save E-29 Appendix C. Troubleshooting Problem Possible Cause Possible Solution With RS232 communication, adapter not inserted Insert the adapter With RS232 communication, communication interface fails. Connect communication port in right way With USB or PS/2 communication, communication interface fails. Connect communication port in right way Engine does not send data to host computer Engine is not connected to the host. Check all cable to host computer. Receive garbled with RS232 Engine and the host baud rate settings are inconsistent Check engine and PC-side communication port baud rate settings are the same Did not enable the barcode Please enable it Engine can not read the barcode by it’s firmware. Please contact the dealer or us Engine does not turn on Engine does not read barcodes E-30 Newland EMEA +31 (0) 345 87 00 33 [email protected] Newland D-A-CH +49 (0) 294 298 76758 [email protected] Newland UK +44 (0) 1442 212 020 [email protected] Newland Nordic +46 (0) 708 847 767 [email protected] Newland Ibérica +34 (0) 93 303 74 66 [email protected] Newland France +31 (0) 345 87 00 33 [email protected] Newland Middle East +31 (0) 345 87 00 33 [email protected] Newland South Africa +27 (0) 11 553 8010 [email protected] Newland Italy +39 (0) 342 056 2227 [email protected] Newland Russia +31 (0) 345 87 00 33 [email protected]