Preview only show first 10 pages with watermark. For full document please download

Fixings Suitable For H+h Aircrete

   EMBED


Share

Transcript

Fixings suitable for H+H aircrete TSD 20  Plugged and Screwed Fixings MANUFACTURER Telephone No: Screw Size* Type of plug WOOD SCREW PLASPLUG 01283 533955 RAWLPLUG Driven direct Plastic (no plug) Heavy Duty Plastic Yellow 01416 387961 Brown Fibre Rawlbloc (Lightweight Block Fixing) UNIFIX 0800 8087172 FISCHER 01491 827900 Nylon Nylon Nylon (formerly by UPAT – now available from FISCHER) Metal (fire resistant) 8 x 50 10 x 37 14 x 37 Small (8/49) Large (10/66) Hi-load LB55/10mm Hi-load LB70/10mm S6 S8 S10 GB8 GB10 GB14 FTPK4 FTPK8 FTPK10 FTPM6 FTPM8 FTPM10 Minimum screw depth into fixing (mm) Individual Fixing Ultimate Pull-Out Force (N) Solar Standard and Higher Strengths No.10 No.10 37 57 600 870 950 Nos 8 & 10 Nos 12 & 14 No. 8 No. 10 No. 14 5 mm 6 mm No. 10 No. 10 No. 10 No. 12 No. 14 5 mm 7 mm 10 mm 4mm 8mm Coach 10mm screw 6mm 8mm 10mm 25 300 - 45 650 - 38 32 40 68 78 70 85 35 46 57 45 58 85 35 45 50 20 25 30 450 900 580 810 745 1400 450 800 900 800 1250 1550 1150 1650 1950 600 1650 1800 1110 730 1200 1450 3600 800 1300 2400 2700 1000 1600 2000 2600 2800 800 1150 - 1200 - - 970 500 1050 1000 1650 - 2000 4500 45 585 *Approximate equivalent screw sizes: No.8: 4mm; No.10: 5mm; No12: 5.5mm; No.14: 6mm; No16: 7mm  Nailed fixings CUT NAIL - driven direct HELIFIX 0208 735 5200 75mm 55 50 into block TurboFast 8mm 70 into block 100 into block LODEN Anchor (fire resistant) 01527 68559 HA75 HB90 SD Heavy Duty (particularly suitable for handrail fixings) 56 into block 56 into block Hammer/screw fixings RAWLPLUG 01416 387961 Rawl-Tap-In 6.5 mm (5 mm screw) - for use into block with unplastered blockwork Notes 1. The diameter of holes drilled in the blocks should be such that the plug fits tightly prior to the screw being driven. Woodscrews driven direct should not be over tightened. Cut nails driven direct should not be over hammered. 2. The size and length of a fixing should be suitable for the block thickness. 3. Generally, fixings should be spaced from each other (and from the free edge of a block when this is applicable) at a distance not less than the depth of penetration of the fixings into the block; this should be confirmed with the fixing manufacturer. 4. Where a comparison is needed between the performance of a fixing listed and a known requirement, we suggest a Safety Factor of 4 be applied. TSD 20 H+H UK Limited, Technical Services Department: Tel 01732 880580 Page 1 of 1 December 2013