Preview only show first 10 pages with watermark. For full document please download

Flavel Renoir Gas Fire Instructions

   EMBED


Share

Transcript

, RENOIR BATTERY IGNITION RADIANT CONVECTOR GAS FIRE Installation, Maintenance & User Instructions Hand these instructions to the user Model No’s FRECN0EN & FRECR0EN are for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B. / I.E. CONTENTS Contents Installation Instructions Appliance Data Section 1 Section 2 Section 3 Section 4 User Instructions Section 5 Page 3 4 4 5 5 5 5 5-6 6 6-7 1.8.3 1.9 1.10 Conditions of Installation. Flue & Chimney Suitability Fireplace/Surround Suitability Shelf Position Side Clearance Closure Plate Flue & Chimney inspection Chimney Catchment space Brick Built Chimney Fitting to Pre-Fab. Twin Wall Metal Flueboxes Fitting to Pre-Cast Flue Installations Hearth Fitting Spillage Monitoring System 13-15 16 3.4 Assembly of Fuelbed Lighting the Appliance Checking for Clearance of Combustion Products Final Checks 5.1 5.2 5.3 5.4 Conditions of installation About your fire Laying the fuel-bed Replacing the battery 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.8.1 1.8.2 2.1 2.2 2.3 2.4 2.5 . 3.1 3.2 3.3 4.1 4.1.1 4.2 4.3 4.4 Packing Check List Installation of Fire Fitting Spigot to Firebox Fitting the battery Gas Tightness General Access for Servicing Removal of the Upper Canopy Removal of the Burner Assembly Removal of the Control Tap Removal of the ODS 2 7 8 8 8 9 9-10 11 12 12 16-17 17 18 18 18-19 19-20 20 21 22-24 25-27 25 APPLIANCE DATA Main injector (1 off) Pilot Type. Type Bray Elbow size 360, Cat 82 Copreci Single Flame 21100 / 161 Max. Gross Heat Input : Min. Gross Heat Input : 6.0 kW 1.8 kW Ignition : Battery Ignition, 1.5V Cold Pressure : Electrode Spark Gap : Weight (Packed) : 20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.) 4.0 mm 25.0kg Firebox Dimensions (with case fitted) Width : (with fender fitted) Height : (with feet fitted) Depth : (with fender fitted) Height to top of the flue spigot Gas Connection : EFFICIENCY DECLARATION 685mm 700mm 325mm : 490mm (with feet fitted) 8mm compression (Supplied with fire) The efficiency of this appliance has been measured as specified in BS 7977-1 : 2002 and the result is 70%. The gross calorific value of the fuel has been used for this efficiency calculation. The test data from which it has been calculated has been certified by BSI. The efficiency value may be used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. 3 1.1 CONDITIONS OF INSTALLATION In Great Britain :- It is law that all gas appliances are installed only by a GAS SAFE registered installer in GB, in accordance with these installation instructions and the Gas Safety (Installation and use) Regulations 1998. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law. The installation must also be in accordance with all relevant parts of the Local and National Building regulations where appropriate, the Building Regulations (Scotland Consolidation) issued by the Scottish Development Department, and all relevant recommendations of the following British Standard Code of Practice. 1. 2. 3. 4. 5. 6. 7. 8. B.S. B.S. B.S. B.S. B.S. B.S. B.S. B.S. 5871. Part 1. Installation of Gas Fires. 5440.: 2000 Parts 1 & 2. Installation of Flues & Ventilation. 6891. Installation of Gas Pipework. 6461. Part 1. Installation of Chimneys & Flues. 1251. Open Fireplace Components. 715. Metal Flue pipes for Gas Appliances. E.N. 1858 Chinmeys Components & Concrete Flue Blocks 7566 Installation of factory-made Chimneys. Ventilation Requirements For use in G.B. purpose built ventilation is not normally required for this appliance. In Republic of Ireland :- For use in I.E. this appliance must be installed in accordance with the rules in force by a competent person and used only in a sufficiently ventilated space. Please consult document I.S. 813 : 1996 Domestic Gas Installation, issued by the National Standards Authority of Ireland. 1.2 FLUE AND CHIMNEY SUITABILITY The appliance is designed for use with conventional brick built chimneys or lined chimneys and pre – fabricated flues. It is also suitable for use with pre-cast flue blocks conforming to BS EN 1858 and metal flue boxes conforming to BS 715. All flues must conform to the following minimum dimensions. Minimum diameter of circular flues Minimum effective height of all flue types Minimum cross sectional area of Pre-cast Flues 4 125 mm 3 metres 122.7 cm2 1.3 FIREPLACE / SURROUND SUITABILITY The fire is suitable for hearth mounting only. It must not be fitted directly onto a carpet or other combustible material. It must not be fitted to combustible walls. This fire is suitable for the following hearth / surround types: Non-combustible hearths / surrounds. Purpose made proprietary hearths / surrounds with a minimum temperature rating of 150oC. If a heating appliance is fitted directly against a wall without the use of a fireplace or fire surround, soft wall coverings such as wallpaper, blown vinyl, etc. could be affected by the heat and may, therefore scorch or become discoloured. Please bear this in mind when installing or decorating. 1.4 SHELF POSITION 1.5 SIDE CLEARANCE 1.6 CLOSURE PLATE 1.7 FLUE / CHIMNEY INSPECTION a) Check that the chimney / flue only serves one fireplace and is clear of any obstruction. Any obstruction. Any dampers or register plates must be removed or locked in the open position. The fire may be fitted below a combustible shelf providing there is a minimum distance of 200 mm above the top of the fire and the shelf does not project more than 150 mm. If the shelf overhangs more than 150 mm the distance between the fire and the shelf must be increased by 25 mm for every 25 mm of additional overhang over 150 mm. A minimum clearance of 100mm should be allowed on either side of the fire for servicing. Any fire surround uprights should not project forward by more than 100mm. NOTE. The fire must be installed so that no part of a combustible side wall when measured laterally is less than 500mm from the radiants. A closure plate is supplied with this fire and must be fitted. The closure plate must be sealed to the fireplace or surround opening with suitable adhesive tape. See section 2.2.2 Before commencing installation, a flue or chimney should be inspected to ensure that all the following conditions are satisfied. 5 b) Brick / stone built chimneys and any chimney or flue which has been used for an appliance burning fuel other than gas must be thoroughly swept. The base of the chimney / flue must also be thoroughly cleared of debris etc. Any under floor air supply to the fireplace must be completely sealed off. Ensure that the inside of the chimney/flue is in good condition along its length and check that there is no leakage of smoke through the structure of the chimney during and after the smoke pellet test. With pre-cast flues it is especially important to check the inside of the flue for extruded cement / sealant protruding from the joints between the flue blocks. If present, these should be removed by rodding the flue before proceeding with the installation. Using a smoke pellet, check that there is a positive up draught present in the chimney / flue and that the smoke can be seen issuing from the terminal / chimney pot outside. There must be no leakage of smoke through the structure of the chimney during or after the smoke pellet test and it is important to check inside upstairs rooms adjacent to the chimney / flue. Check the chimney pot / terminal and general condition of the chimney brickwork or masonry. If the chimney or flue is in poor condition or if there is no up draught do not proceed with the installation. If there is a history of down draught conditions with the chimney / flue, a tested and certified flue terminal or cowl suitable for the relevant flue type should be considered. A spillage test must always be carried out during commissioning of the appliance. 1.8 1.8.1 CHIMNEY CATCHMENT SPACE. Brick Built Chimneys. The catchment space below the flue spigot should be as deep as possible, and must not be less than 250mm measured from the bottom of the flue spigot to the bottom of the catchment space, or to the top of any “bricking-up” of the fireplace, whichever is the least. See Fig. 1. The flue spigot must pass through the closure plate at least 25mm and have a minimum clearance of 50mm between its open end and the nearest obstruction. There must be a minimum clearance of 165mm between the back of the closure plate and the back of the catchment space. See Fig. 1 overpage. 6 The front opening of the fireplace must be between 305mm and 440mm wide, and between 500mm and 650mm high. If the opening is larger than this, then a surround must be constructed in a suitable non-com bustible material to create an opening to these limits. Allow a minimum flat surface of 20mm around the opening to ensure that the closure plate can be sealed to the fireplace. Any surround must be sealed to the fireplace to prevent leakage. The operation of the chimney should be tested a detailed as in section 1.7. Fig.1. 1.8.2 Note. A flue spigot extension of up to a maximum total length of 125mm may be fitted if necessary, providing that a minimum clearance 50mm between its open end and nearest obstruction is always maintained. Chimney Catchment Space. Fitting to Pre-Fabricated twin wall metal Flue Boxes. The appliance may be fitted to a twin wall metal flue box conforming to the constructional requirements of BS 715, (for example the Selkirk LFE 125 box). The box must have a minimum flue diameter of 125mm internal and minimum internal dimensions of 160mm deep by 580mm high by 350mm wide. There are no maximum dimensional requirements for the box. The top face of the box must be insulated with a minimum thickness of 50mm of non-combustible mineral wool insulation or similar material. The flue box must stand on a non-combustible base of minimum thickness 12mm. 7 1.8.3 Fitting to Pre-Cast Flue Installations. 1.9 HEARTH FITTING 1.10 The pre-cast opening must be a minimum of 122.7cm2 or equivalent cross-sectional area and have a minimum effective flue height of 3 metres. This appliance has been tested for use in a precast flue block complying with BS EN 1858. In accordance with BS EN 1858, pre-cast flues built with directly plastered faces (front or rear) are not correctly installed as to ensure proper operation with any type of gas fire. In some instances of this flue construction, temperature cracking of surface plaster may occur through no fault of the appliance. An air gap or some form of insulation material should be installed to prevent normal flue temperatures from damaging wall surfaces. This appliance must only be installed on to a level concrete or noncombustible hearth. The feet must not be removed when installing directly onto a hearth.The hearth material must be a minimum thickness of 13 mm with the top surface at least 50 mm above the floor level. The hearth must be fitted symmetrically about the fire opening and have a minimum width of 760 mm and a minimum projection of 300 mm forwards from the fire opening. SPILLAGE MONITORING SYSTEM This appliance is fitted with an atmosphere sensing spillage monitoring system in the form of an oxygen sensing pilot. This is designed to shut the fire off in the event of partial or complete blockage of the flue causing a build up of combustion products in the room in which the fire is operating. The following are important warnings relating to the spillage monitoring system: The spillage monitoring system must not be adjusted by the Installer. The spillage monitoring system must not be put out of action. When the spillage monitoring system is exchanged, only a complete original Manufacturers part may be fitted. It is not possible to replace individual parts on the pilot system on the appliance, only a complete pilot assembly (including thermocouple) may be fitted. 8 2.1 PACKING CHECK LIST 2.2 INSTALLATION OF FIRE 2.2.1 a) Fig. 2 1 1 1 1 1 1 1 off Firebox / Burner Assembly off Flue Spigot off Closure Plate off Literature / Loose Items Pack off Fuelbed off Coal Pack off AA battery Preparation. Remove the glass panel by rotating the latch to release. Lift the glass panel upwards and lift away. See Fig. 2. Remove the Glass Panel Glass Panel Retaining Latch b) Grasp sides of the of the glass panel and pull lower edge forward. d) To re-fit the glass panel, engage the 2 side glasses in the sealing channels, with the projecting glass edge uppermost. Slide the panel up until the top edge enters the slot, then push the lower edge in and turn the latch to secure it. c) Remove the coal / fuelbed packs that have been retained by the glass panel (not shown in Fig. 2 above) 9 Closure plate a) Fit the closure plate to the fireplace opening and ensure that it has a flat sealing area of at least 10mm sealed on all sides. See Fig. 3 below Dimensions stated are for closure plate supplied Check the operation of the chimney as follows:- Fig. 3 460mm 660mm 462mm to CTR 15mm Air Relief Openings Spigot Opening 168 x 68mm 100mm Closure Plate Dimensions Fireplace Opening Dimensions 525mm Minimum 650mm Maximum Minimum 10mm Flat Sealing Area 305mm Minimum 440mm Maximum Apply a smoke match to the flue spigot opening in the closure plate and observe the smoke. If there is a definite flow into the opening then proceed with the installation. If there is not a definite flow into the opening, pre-heat the chimney for about two minutes and retest for flow. If there still is no definite flow into the opening, the chimney may require attention. DO NOT FIT THE FIRE-SEEK EXPERT ADVICE. 10 2.3 a) Fig. 4 FITTING THE SPIGOT TO THE FIREBOX Screw the firebox spigot to the draught diverter with the four screws, 2 off upper (as shown below in Fig. 4) & 2 off lower screws (not pictured) . 4 off Flue Spigot Fixing screws Note : A means of isolation must be provided near to the appliance to facilitate servicing. Ensure that the gas supply is turned off before commencing. The gas connection should be made to the appliance inlet elbow using 8 mm rigid tubing. The gas connection can be made left hand, right hand or rear. In line with current installation regulations, a restrictor should be fitted to the inlet pipework to isolate the appliance for servicing and repair purposes. Before making the final gas connection, thoroughly purge the gas supply pipe work to remove all foreign matter, otherwise serious damage may be caused to the gas control valve on the fire. 11 2.4 a) Fig. 5 FITTING THE BATTERY The battery holder is located at the bottom R/H/S of the fire, unscrew the cap, fit the AA battery supplied in the loose items pack and re-fit the cap. See Fig. 5 below. Spark Generator Battery Cap AA Battery 2.5 a) b) c) d) GAS TIGHTNESS Remove the pressure test point screw from the inlet elbow and fit a manometer. Turn on the main gas supply and light the fire as described in section 3.2 and carry out a gas tightness test. Check that the gas pressure is 20.0 mbar (± 1.0 mbar), 8.0 in w.g. +/0.4 in w.g. Turn off the fire, remove the manometer and refit the pressure test point screw. Check the pressure test point screw for gas tightness with the appliance turned on using a suitable leak detection fluid or detector. 12 3.1 ASSEMBLY OF THE FUELBED NOTE : The position of the fuel-bed components are critical to the performance of the product. Therefore please ensure that the fuel-bed components are positioned as described in the following section prior to requesting a service call due to soot build up, poor flame pattern etc. a) Fig. 6 Fit the fuelbed base into the combustion chamber as shown below in Fig. 6. Ensure that the slot in the fuel-bed is located onto the lip on the fuel-bed base support. Section View of Fuel-bed Base / Burner Locating Lip on Fuel-bed Support Burner b) Fig. 7 Fit coal “A” onto the fuelbed base in the position as shown below in Fig. 7. The coal form has the individual placement letters stamped on the bottom face. Coal Form “A” 13 c) Fig. 8 Fit coal “B” onto the fuelbed base in the position as shown below in Fig. 8. The coal form has the individual placement letters stamped on the bottom face. Coal Form “B” d) Fig. 9 Fit coal “C” onto the fuelbed base in the position as shown below in Fig. 9. The coal form has the individual placement letters stamped on the bottom face. Coal Form “C” e) Fit coal “D” onto the fuelbed base in the position as shown overpage in Fig. 10. The coal form has the individual placement letters stamped on the bottom face. 14 Fig. 10 Coal Form “D” f) Fig. 11 Fit coal “E” onto the fuelbed base in the position as shown below in Fig. 11. The coal from has the individual placement letters stamped on the bottom face. Coal Form “E” To ensure that the release of fibres from these R.C.F (Refractory Ceramic Fibre) articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within heavy duty polythene bags, clearly labelled as “RCF waste”. RCF waste is classed as a “stable”, non reactive hazardous waste and may be disposed of at a landfill licensed to accept such waste Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area, and always wash your hands before eating or drinking. 15 g) 3.2 a) b) c) d) 3.3 a) b) Note:- Refit the glass panel, ensuring the retaining disc is rotated to secure panel. IMPORTANT: Ensure decorative front casting is fitted prior to light ing appliance. Lighting the Appliance Light the pilot by depressing the control knob at the “off” position and turn anti-clockwise (with the control depressed) to the second position marked *. When the pilot lights, (pilot can be seen through the right hand side window, between the fuelbed base and coals) hold the control knob down for 10 seconds. If the pilot fails to light, repeat the ignition sequence and hold in the control knob for slightly longer. When the pilot has lit, , then release the control knob from the depressed position, depress slightly again and turn the control anticlockwise to the high position and check for clear once of combustion products as detailed below. Checking for Clearance of Combustion Products Close all doors and windows in the room. Light the fire and turn to the maximum position. After 5 minutes hold the smoke match as shown in Fig. 12. Whilst holding the smoke match in the correct position, approximately 25mm below the lower edge of the draught diverter. Ensure that most of the smoke is drawn into the flue aperture. If in doubt repeat the exercise after a further 5/10 minutes. It is recommended that the smoke match is fitted into an approved smoke match holder, when checking for clearance of combustion products. 16 Fig. 12 Smoke Match position Approximately 25mm below and from left hand edge of draught diverter (viewed from rear for clarity of image) 45 degrees Smoke match holder to be inserted at approximely 45 degree angle below side trim If there is an extractor fan fitted in a joining room, then the spillage test must be repeated with the fan switched on and running at maximum speed. All interconnecting doors must be opened in accordance with the latest issue of BS 5440. IF SPILLAGE IS DETECTED The cause must be discovered and the fault corrected. If the fault cannot be corrected disconnect the appliance from the gas supply and seek expert advice. Possible causes of spillage from the appliance are:- chimney restriction, down draught or insufficient air supply to the room. e) 3.4 After ensuring that the fire is safe to use it should be left on “High” position to fully warm up. During this time a slight odour may be noticed, this is due to the “newness” of the fire and will soon disappear. Final Check a) Recheck the operation of the fire on all settings. c) Inform the User that the Model Number for ordering parts is shown on the Rating plate. This is located on the back plate of the fire and can be viewed by looking underneath the burner assembly. Inform the User the fire should be serviced annually for continued safe operation. b) d) Make sure that the User knows how to operate the fire and refer them to the User Book. Hand this instruction booklet to the customer. 17 SECTION 4 - SERVICING / MAINTENANCE INSTRUCTIONS Servicing Notes Servicing should be carried out annually by a competent person such as a GAS SAFE registered engineer. The service should include visually checking the chimney and fire opening for accumulations of debris and a smoke test to check for positive up-draught in the chimney. The condition of the fuelbed ceramics & coals should be checked and if necessary the whole set should be replaced with a genuine replacement set. After any servicing work a gas tightness check must always be carried out. 4.1 GENERAL ACCESS FOR SERVICING a) Prepare work area (lay down dustsheets etc.), Disconnect the appliance from the gas supply. Remove the four canopy rear fixing screws, Remove the glass front panel as descibed on page 9, (fig. 2) Re-assemble in the reverse order. 4.1.1 b) c) d) 4.2 a) b) c) d) Fig. 13 TO REMOVE THE UPPER CANOPY / GLASS PANEL REMOVING THE BURNER ASSEMBLY FROM THE FIRE Prepare work area (lay down dustsheets etc.), Disconnect the appliance from the gas supply. Remove the four canopy rear fixing screws Remove the glass front panel as descibed on page 9, (fig. 2) Remove the pilot retaining screws as shown below in fig. 13 2 off ODS Pilot Retaining Screws 18 e) Fig. 14 Remove the four burner retaining screws as indicated in Fig. 14 below 2 off R/H Burner Retaining Screws 2 off L/H Burner Retaining Screws f) 4.3 a) b) c) d) Fig. 15 Slide the burner assembly to the left, off the injector and remove the from the firebox. REMOVING THE CONTROL TAP / MICROSWITCH FROM THE FIRE Disconnect the appliance from the gas supply. Remove the burner assembly as shown in section 4.2. Disconnect the pilot pipe, inlet pipe,valve to injector pipe and push fit thermocouple as shown below in Fig. 15 Re-assemble in reverse order and carry out a gas tightness test. Pilot Pipe Push Fit Thermocouple Inlet Pipe Valve to Injector Pipe 19 d) Fig. 16 Remove the valve retaining nut as shown below and disconnect the wires to the microswitch as shown below in Fig. 16 Valve retaining nut and microswitch wires d) e) 4.4 Remove the thermocouple, which is a push fit into the rear of the control valve. Re-assemble in reverse order and carry out a gas tightness test. REMOVING THE ODS- PILOT ASSEMBLY Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot it is not possible to replace the thermocouple separately, because the thermocouple position is factory set to a tight tolerance. Any replacement of parts on the pilot requires a complete new pilot assembly. a) b) c) Remove the pilot retaining screws as described in section 4.2 d) & fig. 13 Disconnect the pipe pipe and push fit ignition lead Replacement new ODS in reverse order. Note : Prior to replacing the oxypilot on this product due to suspected failure of the component, please remove all debris that has collected on the lint guard of the oxypilot itself. PARTS SHORTLIST Replacement of any parts must be carried out by a competent person such as a GAS SAFE registered gas installer. The part numbers of the replaceable parts are as follows, these are available from specialist spares stockists whose details can be found on our web site,www.bfm-europe.com, in the ‘stockist’ section. Coal set Fuelbed Gas valve (NG) Rear Fibre board Battery Ignition Generator FC-P085332 B-123570 B-135670 B-65320 B-43040 ODS Pilot (NG) B-48360 ODS Pilot (LPG) B-66920 Gas Valve (LPG) B-137770 Glass Assy (Front)FC-A085705 20 5.1 SECTION 5 - USER INSTRUCTIONS CONDITIONS OF INSTALLATION It is the law that all gas appliances are installed only by a competent (e.g. GAS SAFE Registered) Installer, in G.B. in accordance with the installation instructions and the Gas Safety (Installation and Use) Regulations 1998. Failure to install appliances correctly could lead to prosecution. It is in your own interest and that of safety to comply with the law. The fire may be fitted below a combustible shelf provided that the shelf is at least 200mm above the top of the appliance and the depth of the shelf does not exceed 150mm. The fire may be installed below combustible shelves which exceed 150mm deep providing that the clearance above the fire is increased by 15mm for each 25mm of additional overhang in excess of 150mm. No purpose made additional ventilation is normally required for this appliance when installed in G.B. When installed I.E. please consult document I.S. 813 : 1996 Domestic Gas Installation which is issued by the National Standards Authority of Ireland. Any purpose made ventilation should be checked periodically to ensure that it is free from obstruction. If the chimney or flue has been previously used by appliances burning fuels other than gas they must be swept prior to the installation of this fire. If this appliance is fitted directly on to a wall without the use of a fireplace or surround, soft wall coverings such as wallpaper, blown vinyl etc. could be affected by the heat and hot air and may discolour or scorch. This should be considered when installing or decorating. THIS APPLIANCE MUST NOT BE USED IF THE GLASS PANELS ARE BROKEN OR NOT IN PLACE. The Model number of this appliance is as stated on the rating plate affixed to the inner rear panel of the fire and the appliance is manufactured by:BFM Europe Ltd Trentham Lakes Stoke on Trent ST4 4TJ 21 ABOUT YOUR NEW FLAVEL RENOIR GAS FIRE The Flavel Renoir gas fire incorporates a unique and highly developed heat exchanger which combined with the coal effect gives maximum heat whilst maintaining reasonable running costs Please take the time to fully read these instructions as you will then be able to obtain the most effective and safe operation of your fire. IMPORTANT SAFETY INFORMATION WARNING This appliance has a naked flame and as with all heating appliances a fireguard should be used for the protection of children, the elderly and infirm. Fireguards that conform to B.S. 8423 : 2002 should be fitted. (Fireguards for use with gas heating appliances). It is important that this appliance is serviced at least once a year by a GAS SAFE registered gas installer and that during the service the fire is removed from the fire opening and the chimney or flue visually checked for fallen debris or blockages which must be removed. The chimney should also be checked to ensure clearance of flue products. During the annual service, replacement of the Oxypilot must be carried out, as a condition of the guarantee. After installation or during servicing a spillage test must always be carried out. Only the correct type of coals & fuelbed must be used and only complete and genuine replacement sets can be sourced from BFM Europe Ltd. Always keep furniture and combustible materials well clear of the fire and never dry clothing or items either on or near to the fire. Never use aerosols or flammable cleaning products near to the fire when it is in use. The ceramic coal effect fuel-bed remains hot for a considerable period after use and sufficient time should be allowed for the fire to cool before cleaning etc.The fire must only be operated with the glass panel in place. IMPORTANT: NEVER attempt to light the appliance without the decorative front fender in place 22 5.2 a) b) c) d) e) OPERATING THE FIRE Light the pilot by depressing the control knob at the “off” position and turn anti-clockwise (with the control depressed) to the second position marked *. When the pilot lights, (pilot can be seen between the coals and fuelbed base through the side window) hold the control knob down for 10 seconds. If the pilot fails to light, repeat the ignition sequence and hold in the control knob for slightly longer. When the pilot has lit, release the control knob from the depress position, depress slightly again and turn the control anti-clockwise to the HIGH position. It is recommended that the fire is left in the HIGH position to warm up for approximately 10 minutes before turning to the required heat setting. WARNING: If the fire goes out for any reason or is turned off and it is necessary to relight the fire it is important to allow the fire to cool for 3 minutes before attempting to re-light it. NEVER operate the fire without the decorative front casting in position SPILLAGE MONITORING SYSTEM This appliance is fitted with a spillage monitoring system which shuts down the fire if the evacuation of combustion products from the fire is affected by a partially or fully blocked flue. If this system operates the fire will go out. If this occurs, leave the fire for at least three minutes then follow the lighting procedure as described in the previous section. In the event of repeated operation a GAS SAFE registered gas installer must be called to investigate and rectify the cause. CLEANING - WARNING Before attempting any cleaning operation ensure that the fire has been allowed to fully cool. CLEANING THE FUELBED / COALS We do not recommend regular cleaning of the fuelbed ceramics as these are fragile and damage may result. None of these parts must be washed or exposed to any cleaning agents or water. Any damaged parts must be replaced by contacting your dealer or telephoning BFM Europe Ltd. on the number stated on the rear cover of this book. The fuelbed ceramics must only be replaced with a complete and genuine replacement set and the fire must never be run with the wrong number or damaged coals. The fuelbed ceramics must be carefully re-assembled as stated in pages 6 - 8 of this book. 23 LIGHTING WITH A SPILL Important do not light with a wax taper In the unlikely event of the piezo ignition unit failing to light the fire, turn the control knob to the OFF position, and wait a minute or so for the gas to disperse. The fire can then be lit by using a spill. a) b) c) d) Remove the front casting by lifting upwards. Apply a lighted spill at the pilot tip. Light the pilot by depressing the control knob at the “off” position and turn anti-clockwise (with the control depressed) to the second position marked *. When the pilot lights, remove the spill and continue to hold the control knob down for 10 seconds. If the pilot fails to light, repeat the ignition sequence and hold in the control knob for slightly longer. When the pilot has lit, release the control knob from the depressed position, then refit the decorative front casting, depress slightly again and turn the control anti-clockwise to the high position. Replace the front casting. WARNING: The decorative front casting MUST be fitted prior to turning the control knob to the HIGH position. WARNING : Before attempting any cleaning operation ensure that the fire has been allowed to fully cool. CLEANING THE CASE. Dusting is normally all that is required. But where extra cleaning is necessary, use a damp cloth. 24 5.3 ASSEMBLY OF THE FUELBED a) Fit the fuelbed base into the combustion chamber as shown below in Fig. 1. Ensure that the slot in the fuel-bed is located onto the lip on the fuel-bed base support. NOTE : The position of the fuel-bed components are critical to the performance of the product. Therefore please ensure that the fuel-bed components are positioned as described in the following section prior to requesting a service call due to soot build up, poor flame pattern etc. Fig. 1 Section View of Fuel-bed Base / Burner Locating Lip on Fuel-bed Support Burner b) Fig. 2 Fit coal “A” onto the fuelbed base in the position as shown below in Fig. 2. The coal form has the individual placement letters stamped on the bottom face. Coal Form “A” 25 c) Fig. 3 Fit coal “B” onto the fuelbed base in the position as shown below in Fig. 3 The coal form has the individual placement letters stamped on the bottom face. Coal Form “B” d) Fig. 4 Fit coal “C” onto the fuelbed base in the position as shown below in Fig. 4. The coal form has the individual placement letters stamped on the bottom face. Coal Form “C” e) Fit coal “D” onto the fuelbed base in the position as shown overpage in Fig. 5. The coal form has the individual placement letters stamped on the bottom face. 26 Fig. 5 Coal Form “D” f) Fig. 6 Fit coal “E” onto the fuelbed base in the position as shown below in Fig. 6. The coal form has the individual placement letters stamped on the bottom face. Coal Form “E” To ensure that the release of fibres from these R.C.F (Refractory Ceramic Fibre) articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust accumulated in and around the appliance before and after working on the appliance. When replacing these articles we recommend that the replaced items are not broken up, but are sealed within heavy duty polythene bags, clearly labelled as “RCF waste”. RCF waste is classed as a “stable”, non reactive hazardous waste and may be disposed of at a landfill licensed to accept such waste Protective clothing is not required when handling these articles, but we recommend you follow the normal hygiene rules of not smoking, eating or drinking in the work area, and always wash your hands before eating or drinking. 27 5.4 REPLACING THE BATTERY IN THE IGNITION GENERATOR The battery holder is located at the bottom R/H/S of the fire, unscrew the cap, fit a new AA battery and re-fit the cap. See Fig. 7 below. Fig. 7 Spark Generator Battery Cap AA Battery IN THE EVENT OF THE FIRE FAILING TO LIGHT, PLEASE VISUALLY CHECK FOR SPARKING AT THE IGNITION ELECTRODE ON THE PILOT. IF NO SPARK IS PRESENT PLEASE REPLACE THE BATTERY AS DETAILED IN SECTION 4.5 ABOVE. SERVICE CALLS THAT ARE A DIRECT RESULT OF FLAT BATTERIES WILL BE CHARGED FOR BY THE MANUFACTURER AS THE BATTERY IN THE FIRE IS A CONSUMABLE ITEM THAT WILL REQUIRE ROUTINE REPLACEMENT. 28 Due to our policy of continual improvement and development the exact accuracy of descriptions and illustrations cannot be guaranteed. Part No. B-138560 Issue 3 BFM Europe Ltd Trentham Lakes Stoke-on-Trent Staffordshire ST4 4TJ www.bfm-europe.com Telephone - General Enquiries : Telephone - Service : (01782) 339000 (0844) 7700169