Preview only show first 10 pages with watermark. For full document please download

Floor Kettles Low Height Tilting Gas Model Dhs

   EMBED


Share

Transcript

PROJECT NAME: LOCATION: FLOOR KETTLES ITEM NO: LOW HEIGHT TILTING GAS MODEL DHS Kettle shall be a Groen Model DHS (40 gallon) stainless steel steam jacketed unit, operating with a selfcontained gas heated steam source contained within the unit. QTY: MODEL NO: AIA NO: SIS NO: CONSTRUCTION: Kettle interior shall be of 316 stainless steel with solid one-piece welded construction. The console and all exposed surfaces shall be stainless steel. All controls shall be mounted on the front panel except the thermostat, which is mounted on the trunnion support arm. The kettle body shall be mounted to a heavy-duty stainless steel tilt trunnion. The trunnion assembly is supported by the stainless steel enclosed base. The base shall be provided with stainless steel tubular legs with adjustable bullet feet. The enclosed support base shall contain a smooth operating, self locking tilt mechanism, and shall be of sanitary, dripproof construction, with interior readily accessible for installation or maintenance. The unit shall be furnished with a heavy reinforced bar rim with a welded-in butterfly shaped pouring lip for maximum sanitation and durability. Faucet mounting bracket is standard. FINISH: Kettle interior shall be polished to a 180 emery grit finish. Exterior of kettle shall be finished to a bright high buff finish, ensuring maximum ease in cleaning and maintaining brilliant appearance. ASME CODE,CMA (FORMERLY AGA) DESIGN CERTIFIED, CRN REGISTERED: Unit shall be ASME shop inspected, stamped and registered with the National Board for operation up to a maximum working pressure of 30 PSI. Unit shall be Design Certified by the Canadian Standard Association. Unit shall be registered in Canada with a CRN number. SANITATION: Unit shall be designed and drawoff is specified, outlet shall be equipped with removable 1/4” perforated stainless steel strainer. SELF-CONTAINED STEAM SOURCE: Kettle shall have a gas-heated (natural or propane) self-contained steam source to provide kettle temperatures of 150 to approximately 295˚F. Unit shall be factory charged with water and rust inhibitor to ensure long life and minimum maintenance. CONTROLS: Controls shall include a regulating thermostat, pressure gauge, safety tilt cut-off, safety valve, pressure limit control, water sight glass, low water cut off, a gas regulator valve and electronic ignition module. Power ON switch, Power ON indicator light, LOW WATER indicator light, and heat indicator light are mounted on the kettle support side console. Gas supply shall shut off automatically when unit is tilted. PERFORMANCE FEATURES: Patented fin tube burner assembly delivers 77-80% combustion efficiency; 40 Gallon Model has 150,000 BTU/HR firing rate with 115,500 BTU/HR into the product. Electronic ignition to standing pilot is standard on all models. Unit shall be thermostatically controlled to automatically shut off when desired temperature is reached and turn on when product temperature drops below desired setting. INSTALLATION: Specify natural or propane. Unit manufactured to meet NSF requirements and be NSF listed. requires 1/2” NPT gas line connection and 115 volt electric supply to operate controls. No remote steam source required. DRAWOFF VALVE: A 2” sanitary tangent drawoff ORIGIN OF MANUFACTURE: Designed and is optional. (Add “T” to model designation DHS/T). If Stainless Steel 2/3 Steam Jacketed Kettle, Low Height, Floor Mounted, Tilting, Self-Contained, Gas Heated, 40-Gallon Capacity. Model DHS shown. manufactured in the United States. OPTIONS/ACCESSORIES: Water fill faucets 2” tangent draw-off (TDO) valve with 1/4” perforated strainer Kettle brush kit Lift off cover Counterbalanced hinged cover 1/4” perforated strainer 1/8” perforated strainer Solid disk strainer Contour measuring strip Gallon etch marks Lip strainers Pan carrier (40 and 60-gallon) Floor Kettles 160187 RevE Revised 10/13 E WALL 6" MIN. (152) LEFT SIDE CLEARANCE N 2" (51) F P (46) TYP. 1-13/16" 2" (51) TYP. 4-5/8" (117) C FRONT VIEW B ELECTRICAL CONNECTION 1/2" WATERTIGHT CONDUIT CONNECTOR PROVIDED (BACK SIDE) (SEE NOTE 4) ADJUSTABLE FEET A ID 6-1/2 (165) 1. SET THERMOSTAT TO "OFF". 2. SET POWER SWITCH TO "OFF". TO STOP 1. SET POWER SWITCH TO "OFF". 2. SET THERMOSTAT TO "OFF". 3. OPEN GAS SUPPLY VALVE. 4. SET POWER SWITCH TO "ON", 5. ROTATE THERMOSTAT UNTIL HEAT LIGHT IS ON. 1-2 LOW HEAT (SIMMER), 8-9 HIGH HEAT (BOIL) 6. HEAT LIGHT IS ON WHEN MAIN BURNER IS ON. TO START R 6" (152) 4-1/2" (114) 29" (737) OPTIONAL FAUCET 10" REAR FIRING RATE G 6" MIN. (152) 7-1/2" MAX. (191) OPTIONAL 2" (51) TANGENT DRAWOFF KETTLE IN FULL TILT POSITION M POUR PATH MAX. J RIGHT SIDE VIEW L K POUR PATH MIN. 5-1/2" (140) 18 MIN. REAR CLEARANCE FOR TILTING 10" (254) WALL M 150,000 150,000 FAUCET BRACKET FURNISHED AS STANDARD K L 14" W.C. MAX. 14" W.C. MAX. N P H J 11" W.C. 12" W.C. MIN. 3.5" W.C. A B C D E F G 4.5" W.C. MIN. PROPANE GAS TABLE OF DIMENSIONS 483 19 191 7 1/2 P/N 139159 REV B DO NOT SCALE DRAWING SCALE: .05"=1" 1/2" NPT GAS INLET 1003 39 1/2 1537 826 60 1/2 699 32 1/2 305 12 27 1/2 711 28 1032 37 40 5/8 876 940 34 1/2 784 1194 30 7/8 47 MM 762 30 INCHES 40 GAL/152 LITRES CAPACITY (GALLONS/LITRES) GAS OPERATING PRESSURE RECOMMENDED INCOMMING PRESSURE NATURAL GAS 10" FOR SERVICING 6" RIGHT SIDE 10" 6" 6" LEFT SIDE NOTES : 1. OPTIONAL EXTRA COST FEATURES: A. 2" TANGENT SANITARY DRAW-OFF B. FAUCET WITH SWING SPOUT C. MODEL #31 LIFT OFF COVER. 2. DIMENSIONS IN BRACKETS ( ) ARE MM. 3. ELECTRICAL SUPPLY: 115/1/60 @5 AMPS. 4. CUSTOMER TO SUPPLY WATER RESISTANT CONDUIT FITTING FOR ELECTRICAL SUPPLY. CL OF ELECTRICAL 2-1/4" (57) H KETTLE TILT HANDLE 4-1/2" (114) CL OF ELECTRICAL 3. CHECK FOR VACUUM IN KETTLE. PRESSURE GAUGE SHOULD READ BETWEEN 20" Hg to 30" Hg WHEN KETTLE IS COLD. 4. IF REQUIRED, ESTABLISH VACUUM. a. HEAT KETTLE UNTIL PRESSURE GAUGE SHOWS 5 PSI. b. LIFT SAFETY VALVE LEVER TO VENT KETTLE. *** WARNING *** ESCAPING STEAM CAN CAUSE SEVERE BURNS !! c. ALLOW LEVER TO SNAP CLOSED. OFF POWER ON 1. READ AND UNDERSTAND OPERATORS MANUAL. 2. CHECK FOR WATER IN KETTLE. LEVEL MUST BE ABOVE "MINIMUM". BEFORE OPERATION LOW WATER HEAT 6-1/8" (156) 12-5/8" (321) D GAS INLET 1/2" NPT RECOMMENDED DISTANCE INSTALLATION CLEARANCES MINIMUM DISTANCE FROM COMBUSTIBLE WALLS DHS P/N 139159 REV B 1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net © 2013 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.