Transcript
1
Flush mounted LINEA 2000 METAL entrance panel
3 343001-343002
3 8
4
7
Flush mounted 2-wire audio and video speaker module with Zamak front cover, colour camera and night viewing white LED light. One and two-family version available. The camera can be swivelled by +/-20°, both horizontally and vertically. It provides the possibility of opening an electrical door lock connected directly to clamps S+ and S- (18 V 4 A impulsive, 250 mA holding current). Flush mounted box supplied as standard.
6
346250 (gate release relay module) Technical data
3
3
8
4
7
5
6
6
Zamak front without panel
2
9 10
11
9 10
11
J2
14
N
P
Dimensional data
6
2
Related items
Power supply from SCS BUS: 18 - 27 Vdc Stand by absorption: 40 mA Max. operating absorption: 160 mA Operating temperature: (-20) - (+70)°C PI against mechanical impact IK10 Sensor: 1/3” Lens: f: 4,3 mm; F: 1.5 mm Interlace: 2:1 Resolution: 330 horizontal lines Night lighting: white LEDs Brightness adjustment: automatic
5 1
TS
Rear view
BUS
PL S+ S−
13
12 J2
P
14
N
163 mm
136 mm
TECHNICAL SHEETS - VIDEO DOOR ENTRY SYSTEM
Description
TS
Legend
BT00117-b-UK
1 - Loudspeakers BUS PL S+ S− 2 - Colour camera 3 - White LEDs for night lighting 4 - Green LED for door status notification 5 - Microphone 6 - Call keys 13 12 7 - Green LED: put through call notification Red LED: busy system notification 8 - Green LED: active communication notification 9 - Microphone volume adjustment 10 - Loudspeaker volume adjustment 11 - J2: when connected, two columns of call pushbuttons are active, when disconnected only one 12 - Door lock connection and local open door pushbutton 13 - Connection to the 2-wire SCS BUS. 14 - Configurator socket
1
343001-343002 Configuration The device must be configured as follows: P - entrance panel number The configurator in seat P of the speaker module assigns to it a recognition number inside the system. The numbering of the entrance panels must always start from P=0. The entrance panel configured with P=0 must be a common (or main) entrance panel. N - call number Assigns the correspondence between the entrance panel pushbuttons and the audio handsets or video handsets. In the common entrance panels made with pushbutton modules, 1 must be inserted in N of the speaker module. The number of the first riser handset must be inserted in the local entrance panels in N.
1
T - door lock relay timing configurator number 0= No configurator 4 sec.
1
2
3
1 sec. 2 sec.
3 sec.
4*
5
as 6 sec. pushbutt.
6
2
7
8 sec. 10 sec.
* Operation as pushbutton for 10 sec. max, after which standby mode is activated.
To extend operation time over 10 seconds, use actuator item 346200 configured with MOD=5.
S-type of call signal with entrance panel door lock opening notification beep The configuration of S determines the call tone of the SPRINT handsets. One can thus differentiate the calls from different entrance panels. Table for SPRINT handset call signal Configurator Type of bell
0 2-tone 1200Hz 600Hz
1 2-tone 1200Hz 0 Hz
2 2-tone 1200Hz 2400Hz
3 One-tone 1200Hz
For the SWING, PIVOT, POLYX and AXOLUTE handsets, the S configurator associates the Entrance panel to the bell programmed in the same apartment. It is possible to chose between 16 different bells. In one-family systems, S=9 configures the general call and the handsets ring, the same as with the S=0.
Installation The camera must not be installed in front of intense light sources, or in locations where the subject might be backlit. To avoid these problems try to change the installation height of the camera, normally from 160-165 cm, to a height of 180 mm, and to direct the lens downwards so that the shooting quality may be improved. In low light conditions, the picture of the colour camera may be reproduced with a lower colour rendition, in order to ensure the possibility to better identify the subject. For optimum rendition, it is however recommended that an extra light sources is installed in scarcely illuminated locations.
Flush mounted box
S-type of call signal without entrance panel door lock opening notification beep The configuration of S determines the call tone of the SPRINT handsets. One can thus differentiate the calls from different entrance panels.
Frame Speaker module
Table for SPRINT handset call signal BT00117-b-UK
Configurator Type of bell
4 2-tone 1200Hz 600Hz
5 2-tone 1200Hz 0 Hz
6 2-tone 1200Hz 2400Hz
7 One-tone 1200Hz
For the SWING, PIVOT, POLYX and AXOLUTE handsets, the S configurator associates the Entrance panel to the bell programmed in the same apartment. It is possible to chose between 16 different bells. In one-family systems, S=8 configures the general call and the handsets ring, the same as with the S=0.
2
Protrusion from the wall: 21 mm