Transcript
DataSheet
Diplexer Optical Block (DOB) for G-PON DFB 1310T/ APD 1490R O/E characteristics
1、 、Table1 Absolute Maximum Ratings Parameter
Symbol
Min.
Typ.
Max.
Unit
Ts
-40
85
℃
Operating Case Temperature
Top
-40
85
℃
Reverse Voltage(LD)
VRL
2
V
Forward Current(LD)
IFL
150
mA
2
mA
Storage Temperature
MPD Forward Current Reverse Voltage(Rx14)
VRAPD
Vbr
V
Reverse Current(Rx14)
IRAPD
3
mA
Forward Current(Rx14)
IFAPD
2
mA
4
V
TIA Supply Voltage
2、 、Digital Transmitter (Tx13) (Case Operating Temperature -40℃ ℃ Parameter
Symbol
Condition
Min.
Data Rate Center Wavelength Side Mode Suppression Rati
Typ.
Max.
1244 λc SMSR
CW
1290
CW
30
Spectrum Width(-20 dB)
∆λ
Output Optical Power
Pf
Threshold Current
Ith
CW
Slope Efficiency
S
W/A
CW(Note1)
IPD
CW,If=Ith+20mA
Monitor Capacitance
Cm
VR= 5V, f= 1MHz
Tracking Error
TE
Rise/Fall Time
TR/F
CW
Unit Mb/s
1330
nm dB
CW
Monitor PD Current
to +85℃ ℃)
1 3
nm dBm
48
mA
1
mA
7
pF
1.5
dB
320
ps
0.04 0.1 5 -1.5 -
280
Note1: Specified at CW operation, full temperature range assuming the modulation current of 100 m A using the worst case slope efficiency of 0.04. Tracking error is included in the TX output power range.
All contents are Copyright © 1996 - 2009 Wavesplitter Technologies, Inc. All rights reserved. Preliminary and Proprietary
www.wavesplitter.com
Page 1of 4
Diplexer Optical Block (DOB) for G-PON DFB 1310T/ APD 1490R
3、 、Digital Receiver (Rx14) (VCC = 3.3 V, Case Operating Temperature -40℃ ℃ Parameter
Symbol
Condition
Min.
Typ.
Bit Rate λc
CW
Sensitivity
S
BER=10-10, PRBS23, ER=10dB
APD Breakdown Voltage
1480
POVLD VBR
Id=100 uA
Unit Mb/s
1500
nm
-31
dBm
-6
dBm
50
V
VBR-3
APD Bias Voltage Temperature Coefficient of Breakdown Voltage APD Capacitance
Max.
2488
Center Wavelength
Optical Overload
to +85℃ ℃)
V 0.075
CAPD
Vop=0.9VBR, f=1MHz
0.4
0.5
V/℃ pF
4、 、Other Optical Characteristics (Case Operating Temperature -40℃ ℃ to +85℃ ℃) Parameter
Condition
Min.
Typ.
Max.
Unit
Optical Isolation
From external 1310nm to 1490nm Rx
-30
dB
Optical Isolation
From external λ<1450 & λ>1530nm to 1490nm Rx
-20
dB
Optical Isolation
From externalλ<1441 & λ>1539nm to 1490nm Rx
-35
dB
Optical Cross-Talk
From internal 1310nm Tx to 1490nm Rx
-47
dB
Optical Return Loss
1310 nm
-6
dB
Optical Return Loss
1490 nm
-20
dB
All contents are Copyright © 1996 - 2009 Wavesplitter Technologies, Inc. All rights reserved. Preliminary and Proprietary
www.wavesplitter.com
Page 2of 4
Diplexer Optical Block (DOB) for G-PON DFB 1310T/ APD 1490R
Mechanical spec
All contents are Copyright © 1996 - 2009 Wavesplitter Technologies, Inc. All rights reserved. Preliminary and Proprietary
www.wavesplitter.com
Page 3of 4
Diplexer Optical Block (DOB) for G-PON DFB 1310T/ APD 1490R
Revision History Revision
Date
Content
1
11-Jun-2009
---
2
22-Jul-2009
Add mechanical drawing
America Headquarters 46824 Lakeview Blvd. Fremont, CA 95438 USA Tel: 510-651-7800 Fax: 510-651-7822
Taipei Branch 5F, No 3-2 (Building H), Yuan-Qu Street Nan-kang, Taipei 115, Taiwan R.O.C. Tel: +886-2-2782-5780 Fax: +886-2-2782-5782
ShenZhen Branch 5F, 7th Building, Tian'an Industrial Zone, Dengliang Road, NanShan Area, ShenZhen China Tel: +86-755-86265980 ; Fax: +86-755-26642741
All specification data are accurate on the date of publication for product comparisons and ordering information.Wavesplitter Technologies, Inc. reserves the right to change specifications without notice.
All contents are Copyright © 1996 - 2009 Wavesplitter Technologies, Inc. All rights reserved. Preliminary and Proprietary
www.wavesplitter.com
Page 4of 4