Preview only show first 10 pages with watermark. For full document please download

Four Output Signal Splitter 24/12 Vdc

   EMBED


Share

Transcript

Danntech Process Instrumentation Danntech Four Output Signal Splitter 24/12 VDC Price: Call for Pricing Four isolated outputs are produced from a single analogue input. Useful for sending isolated primary measurements to several input devices. Using the two digital inputs any of the four inputs can be selected to be replicated at all four outputs. Outputs can be: Voltage: 0-10 V and ±10 V at up to 5 mA, with maximum ±12 V. Current: 0-20 mA, 4-20 mA, 0-5 mA or 0-1 mA. Maximum 500 Ω. Auxiliary supply can be 24 or 12 VDC. Specifications: • Four analogue inputs - 0-20 mA, 4-20 mA or 0 - 10 V DC, ±10V (others on request). • Four analogue outputs - 0-20 mA, 4-20 mA or 0-10 V, ±10V. • Two Digital Inputs – 15 to 30 VDC at 12 mA maximum, optically isolated, polarity protected to select which input (of the four) is mapped to the outputs. • Two Digital Outputs – 30 V at 30 mA maximum, optically isolated. • Optional RS232 and RS485 communications. • ±10% over and under-range on the inputs and outputs. • Input Impedance – Voltage Input: > 100 kΩ. • Input Impedance – Current Input: 100 Ω. • Input Analogue to Digital Resolution – 10 bits or approximately 0.3% of full scale input. Copyright ©2017 - Danntech - http://danntech.com Page 1 of 2 • Output load >2 k& for voltage outputs and 500 & maximum for the current output. Output Current Maximum – Voltage Output: 5 mA. • Output Current Maximum – Current Output: 22 mA. • Output Current Minimum – Current Output: 0.2 mA. • Output Voltage Maximum – Current Output: 12 V. • Output Voltage Minimum – Voltage Output: -12 V • Output Digital to Analogue Resolution – 12 bits or approximately 0.06% of full scale output. • Output zero and span software adjustable. • Linearity better than 0.2% of full scale. • Power On LED (green) flashing at approximately 1 Hz. • Step Response – Input to Output: approx 2 mSec. • Auxiliary Power Supply: 24 VDC +10%, -5% at 200 mA max. (by special request 12 VDC models can also be supplied) • Isolation between input, output and auxiliary power supply >1000 VAC. • Operating temperature -10°C to 60°C, storage temperature -20°C to 70°C. Calibration sheet provided for each unit manufactured. • DIN rail mounting. • Plug-in screw terminal connections. • Weight – 275 g. • Weight with packaging – 400 g. • Dimensions 45 x 100 x 113 mm (W x H x D). Vendor Information Copyright ©2017 - Danntech - http://danntech.com Page 2 of 2