Preview only show first 10 pages with watermark. For full document please download

Fox Ii T Hd 4k • Setup Guide

   EMBED


Share

Transcript

NT: ompletned RTAfor the cio O ns, a P m IM n.co truct the g ins tro w.ex tallation onnectin . e c o ww s Go t uide, in s before er sourc g w n user cificatio o the po spe roduct t p FOX II T HD 4K • Setup Guide This guide provides quick start instructions for an experienced installer to set up and operate the Extron FOX II T HD 4K Fiber Optic Transmitter. The transmitter is compatible with all Extron FOX II receivers. WARNING: The FOX II T HD 4K outputs continuous invisible light (Class 1 rated), which may be harmful to the eyes; use with caution. Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged. CLASS 1 LASER PRODUCT, see the FOX II T HD 4K User Guide, at www.extron.com. AVERTISSEMENT : Le FOX II T HD 4K émet une lumière invisible en continu (conforme à la classe 1) qui peut être dangereux pour les yeux, à utiliser avec précaution. Branchez les protections contre la poussière dans l’ensemble émetteur/récepteur lorsque le câble fibre optique est débranché. Produit laser de classe 1, voir le FOX II T HD 4K User Guide sur www.extron.com (en anglais). Installation Step 2 — Input and Output Connections a. RS-232 AUDIO RETURN OUT AUDIO L 50-60 Hz HDMI R L RS-232 LOOP THRU ALARM Tx Rx G 1 2 T HD 4K Rx RESET OPTICAL FOX II T HD 4K Transmitter Rear Panel Connect an HDMI video source to the HDMI input connector. HDMI b. If desired, connect an HDMI video display to the Loop-Thru connector for a local display. c. Tx REMOTE R FOX LINK INPUTS IR Tx Rx G Tx Rx OVER FIBER Turn off or disconnect all equipment power sources and mount the transmitter as required. For mounting details and considerations, see the FOX II T HD 4K User Guide at www.extron.com. 100-240V ~ 0.5A MAX LINK Step 1 — Mounting LOOP THRU Connect an audio input device to either the Audio 3.5 mm mini jack or the Audio 5-pole captive screw connector. See the drawing below step 2d to make connections on the captive screw connector. AUDIO L d. For optional returned audio, connect an audio output device to the Audio Return Out 5-pole captive screw connector. See the drawing below to make connections on the captive screw connector. R R Balanced Stereo Input Unbalanced Stereo Input No Ground Here Tip Ring Sleeves Tip Ring R No Ground Here Unbalanced Stereo Output L R Tip Sleeves Tip L • Pour l’audio asymétrique, connectez les manchons au contact au sol. Ne PAS connecter les manchons aux contacts négatifs (–). Tip Ring Sleeves Tip Ring L • For unbalanced audio, connect the sleeves to the ground contact. DO NOT connect the sleeves to the negative (–) contacts. AUDIO RETURN OUT L R Tip Sleeve Tip Sleeve L ATTENTION: R Balanced Stereo Output Do not tin the wires! NOTE: For returned audio, above, you must also do the following: • Connect an audio input device to the Audio Return In 5-pole captive screw connector on the receiver. • Install the optional Receiver-Tx-to-transmitter-Rx cable in step 3b. e. RS-232 Device Gnd Rx Tx Gnd Tx Rx IR NOTE: For returned RS-232 and IR responses (from the receiver to the transmitter, you must install the Receiver-Tx-to-transmitter-Rx cable in step 3b. RS-232 Tx Rx G Tx Rx If you want the FOX II units to pass serial or IR data or control signals, such as for serial control of a projector, connect the master device to the transmitter and the slave device to the receiver via the Over Fiber 5-pole captive screw connector. OVER FIBER IR Device 1 FOX II T HD 4K • Setup Guide (Continued) f. For remote monitoring of the status of the Rx optical link, connect a locally constructed or obtained device to the two rightmost Alarm poles of the Alarm and Remote RS-232 5-pole captive screw connector. The unit shorts both poles together when no light is detected. REMOTE RS-232 ALARM Tx Rx G 1 2 NOTE: The transmitter Alarm port reports the status of the link from the receiver. g. For remote control of a unit and loading firmware, connect a host device, such as a computer or control system, to either of the following ports: Configuration port — The front panel mini USB connector. CONFIG NOTE: Extron recommends performing firmware updates via the Configuration port only. Remote RS-232 port — The rear panel Remote RS-232 port, the 3 leftmost poles of this 5-pole captive screw connector. The protocol for the Remote port is as follows: • • no parity no flow control • 8 data bits Step 3 — Throughput Connections NOTE: See the two fiber cable connection drawing at right. You can connect the transmitter to a compatible receiver in one of two ways: • One way (transmitter to receiver) only, perform step 3a. ALARM Tx Rx G 1 Tx 2 Rx LINK 9600 baud 1 stop bit RS-232 LINK • • REMOTE OPTICAL Transmitter 1 2 • Two way (transmitter to receiver and return), perform steps 3a and 3b. a. Connect the fiber between the Tx port on the transmitter and the Rx port on the receiver (1, at right). b. If you want the receiver to return serial data (such as responses from a controlled device) to the transmitter, connect a cable between the Tx port on the receiver and Rx port on the transmitter (2). 1 Tx Rx LINK NOTE: The Link LEDs indicate transmission of light only, not whether there is data encoded in the optical link. 2 LINK Tx Link and Rx Link LEDs — When lit, the link is active (light is output [Tx] or received [Rx]). Receiver OPTICAL 2 Operation After the receiver, the transmitter, and their connected devices are powered up, the system is fully operational. If any problems are encountered, verify that the cables are routed and connected properly and that the display device has a compatible resolution and refresh rate. If problems persist, call the Extron S3 Sales & Technical Support Hotline. See the contact numbers on the last page of this guide for the Extron office nearest you. Indications Power LED — Indicates that power is applied to the unit. Video LEDs — VIDEO Signal LED — Lights when the unit detects an input video signal. CONFIG HDCP LED — Lights when the input signal is HDCP encrypted. AUDIO SIGNAL INPUT HDCP RETURN OUT EDID SELECT Audio LEDs — Input LED — Lights when an analog audio or PCM digital audio signal remains above -35 dBV. The LED goes unlit if the audio signal level drops below the threshold for 10 seconds or longer. Return Out LED — Lights when analog audio is present on the transmitter Return Audio Output connector. EDID EDID Select rotary switch — Set this switch to one of the positions shown in the table below to select the source of the DDC or a specific resolution. Position 0 — An EDID that has previously been captured from a connected display or manually imported via an SIS command or the Product Configuration Software. Position 1 — The EDID is selected via the remote or USB port on the transmitter only, using an SIS command or the Extron Product Configuration Software. Position 2 — Use the EDID from the display connected to the receiver. NOTE: EDID from the display connected to the receiver requires connection of both fiber cables. Position 3 — Use the EDID from the display connected to the transmitter loop-through. Positions 4 through E — Specify a resolution. The table at right identifies the resolutions associated with the switch positions. All resolutions are at 60 Hz with the exception of 4096x2160 (E), which is 30 Hz. Position F — No EDID assigned. Pos. Source or resolution 0 User recorded EDID 1 Selected via RS-232 2 Display on Rx output 3 Display on Tx loop-through 4 1280x720 5 1280x800 * 30 Hz Pos. 6 7 8 9 A B Resolution 1366x768 1440x900 1680x1050 1920x1080 1920x1200 2048x1536 Pos. C D E* F Resolution 2048x2160 2560x1600 4096x2160 N/A 3 FOX II T HD 4K • Setup Guide (Continued) Application Diagram Extron FOX T HD 4K Fiber Optic Transmitter Extron IPCP Pro 250 IP Link Pro Control Processor IPC P PR O 25 0 Ethernet L I/O DIG M D X TH M L DIO PU TS AU L G AR Tx Rx G 1 Tx M AL R Rx G Tx RTS CTS V C 4 3 2 G AYS REL C 1 VOL Rx eBU +V +S G IR/S S -S 2 LAN G S = G 6W OUT G PWR ET RES TCP/IP Network Rx Tx E LINK Rx T MO RE 232 S- LINK OVER FIBER RS Tx DIO UT AURN O TU RE R Tx ER POW X 12V MA --A Rx 1 1 CO FO IR -232 ITA 2 CO 4K AL TIC OP 2 RS-232 R Ethernet 240V 100- 5A ~ 0. OP r ne Audio RU TH LO e lum 4 ts te Mu HDMI Downscaled to 1080p st La 9 er Ent 0 ber em Dec p Hel re Mosets Pre dio Auntrol Co tem Sys Off 8 7 n ree Sc 15, 201 3- 8 AM 7:5 E ttrxon nEoxr ng hti Lig Extron TLP Pro 720T 7" Table Top TouchLink Pro Touchpanel Up to 30 km (18.75 miles) Singlemode Fiber SM Model S TU STA Y PLA R WE PO US 6 5 om Ro ol ntr Co Local Monitor CA 1 te Mu 4K HDMI SD 2 y On Off Hz se 3 pla Dis MI 50 an Ch Tu op Pre l ne Lapt HD -60 3 Vo VCR DVD PC MAX 12 r Tune Doc Cam IN B RD Extron XPA 1002 02 A 10 XP S2 G T RIN TPU 2 WI OU AS CL 1 Power Amplifier TE MO RE 4K Media Player UTS mA 50 TE /MU 10V VOL INP 2 1 EL LEV STA Y NDB 2 1 1 0Hz , 50-6 1.3A 240V R/ ITE T LIM EC OT PR NAL SIG 0 2 0 100- P 4K RD X L S DIO UT TP AU OU Extron FOX R DP 4K Fiber Optic Receiver 240V 100- AX AM ~ -.- -60 50 Hz YP LA R L Rx G T MO RE 232 SRx G M AR AL 1 RES ET Rx Tx E R Tx Tx Rx LINK Tx DIO IN AU RN TU RE R LINK OVER FIBER FO IR -232 RS AL TIC OP 2 Audio T OR P DIS RS-232 4K DisplayPort L 80 MO DE Extron SI 28 Surface-mount Speakers Extron Headquarters +800.633.9876 Inside USA/Canada Only Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX 4 Extron Europe +800.3987.6673 Inside Europe Only +31.33.453.4040 +31.33.453.4050 FAX Extron Asia +65.6383.4400 +65.6383.4664 FAX Extron Japan +81.3.3511.7655 +81.3.3511.7656 FAX Extron China +86.21.3760.1568 +86.21.3760.1566 FAX 4K Display Extron Middle East +971.4.299.1800 +971.4.299.1880 FAX Extron Korea +82.2.3444.1571 +82.2.3444.1575 FAX Extron India 1800.3070.3777 (Inside India Only) +91.80.3055.3777 +91.80.3055.3737 FAX © 2015 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68-2300-50 Rev. Ax 04 15