Preview only show first 10 pages with watermark. For full document please download

Fox Ii T/r Dp 4k Setup Guide

   EMBED


Share

Transcript

NT: ompletned RTAfor the cio O ns, a P m IM n.co truct the g ins tro w.ex tallation onnectin . e c o ww s Go t uide, in s before er sourc g w n user cificatio o the po spe roduct t p FOX II T/R DP 4K • Setup Guide This guide provides quick start instructions for an experienced installer to set up and operate the Extron FOX II T/R DP 4K Fiber Optic Extenders. WARNING: The FOX II T/R DP 4K outputs continuous invisible light (Class 1 rated), which may be harmful to the eyes; use with caution. Plug the attached dust caps into the optical transceivers when the fiber cable is unplugged. CLASS 1 LASER PRODUCT, see the FOX II T/R DP 4K User Guide, at www.extron.com. AVERTISSEMENT : Le FOX II T/R DP 4K émet une lumière invisible en continu (conforme à la classe 1) qui peut être dangereux pour les yeux, à utiliser avec précaution. Branchez les protections contre la poussière dans l’ensemble émetteur/récepteur lorsque le câble fibre optique est débranché. Produit laser de classe 1, voir le FOX II T/R DP 4K User Guide sur www.extron.com (en anglais). L 50-60 Hz DISPLAYPORT R L Tx Rx G Tx Rx R RS-232 LOOP THRU b. If desired, connect a DisplayPort video display T DP 4K Rx 2 RESET OPTICAL FOX II DP 4K Transmitter Rear Panel RS-232 OUTPUTS AUDIO L 50-60 Hz AUDIO RETURN IN R L IR Tx Rx G Tx Rx Tx REMOTE R RS-232 DISPLAYPORT FOX ALARM Tx Rx G 1 R DP 4K Rx LINK Step 2 — Input and Output Connections Connect a DisplayPort DISPLAYPORT LOOP THRU video source to the transmitter DisplayPort input connector. ALARM Tx Rx G 1 100-240V ~ -.-A MAX a. Tx REMOTE OVER FIBER Turn off or disconnect all equipment power sources and mount the transmitter and receiver as required. For mounting details and considerations, see the FOX II T/R DP 4K User Guide at www.extron.com. AUDIO RETURN OUT AUDIO FOX LINK INPUTS Step 1 — Mounting IR OVER FIBER RS-232 LINK 100-240V ~ -.-A MAX LINK Installation 2 RESET OPTICAL FOX II DP 4K Receiver Rear Panel to the transmitter Loop-Thru connector for a local display. c. Connect a DisplayPort video display to the receiver DisplayPort output connector. DISPLAYPORT d. Connect an audio input device to either the Audio 3.5 mm mini jack or the Audio 5-pole captive screw connector AUDIO L on the transmitter. See the drawing below step 2g to make connections on the captive screw connector. e. Connect an audio output device to either or both the 3.5 mm mini jack or the Audio 5-pole captive screw connector on the receiver. See the drawing below step 2g to make connections on the captive screw connector. f. For optional returned audio, connect an audio output device to the Audio Return Out 5-pole captive screw connector on the transmitter. See the drawing below step 2g to make connections on the captive screw connector. g. AUDIO RETURN OUT L R R AUDIO RETURN IN L R For optional returned audio, connect an audio input device to the Audio Return In 5-pole captive screw connector on the receiver. See the drawing below to make connections on the captive screw connector. L Tip Ring Sleeves Tip Ring R Balanced Stereo Input Unbalanced Stereo Input No Ground Here R Unbalanced Stereo Output Tip Ring Sleeves Tip Ring L No Ground Here R Do not tin the wires! Tip Sleeves Tip L • Pour l’audio asymétrique, connectez les manchons au contact au sol. Ne PAS connecter les manchons aux contacts négatifs (–). R Tip Sleeve Tip Sleeve • For unbalanced audio, connect the sleeves to the ground contact. DO NOT connect the sleeves to the negative (–) contacts. L ATTENTION: Balanced Stereo Output NOTE: For returned audio, above, and RS-232 and IR responses (from the receiver to the transmitter), on the next page, you must install the receiver-Tx-to-transmitter-Rx cable in step 3b. 1 FOX II T/R DP 4K • Setup Guide (Continued) h. If you want the FOX II DP 4K units to pass serial or IR data or control signals, such as for serial RS-232 Device Gnd Rx Tx REMOTE RS-232 ALARM Tx Rx G 1 2 IR For remote monitoring of the status of the Rx optical link on either the transmitter or receiver, connect a locally constructed or obtained device to the two rightmost poles of the Alarm and Remote RS-232 5-pole captive screw connector on that unit. The unit shorts both poles together when no light is detected. RS-232 i. Tx Rx G Tx Rx control of a projector, connect the master device to the transmitter and the controlled device to the receiver via the Over Fiber 5-pole captive screw connectors on both units. OVER FIBER Gnd Tx Rx IR Device NOTE: The transmitter port reports the status of the link from the receiver. The receiver port reports the status of the link from the transmitter. j. For remote control of a unit and for loading firmware, connect a host device, such as a computer or control system, to either of the following ports on the unit to be controlled: Configuration port — The front panel USB mini-B connector. CONFIG NOTE: Extron recommends performing firmware updates via the Configuration port only. Remote RS-232 port — The rear panel Remote RS-232 port, the 3 leftmost poles of this 5-pole captive screw connector. The protocol for the Remote port is as follows: • • no parity no flow control • 8 data bits Step 3 — Throughput Connections NOTE: See the two fiber cable connection drawing at right. You can connect the transmitter and receiver in one of two ways: • One way (transmitter to receiver) only, perform step 3a. ALARM Tx Rx G 1 Tx 2 Rx LINK 9600 baud 1 stop bit RS-232 LINK • • REMOTE OPTICAL Transmitter 1 2 • Two way (transmitter to receiver and return), perform steps 3a and 3b. Connect the fiber between the Tx port on the transmitter and the Rx port on the receiver (1, at right). b. If you want the receiver to return serial data (such as responses from a controlled device), IR data, or returned audio to the transmitter, connect a cable between the Tx port on the receiver and Rx port on the transmitter (2). Tx Link and Rx Link LEDs — When lit, the link is active (light is output [Tx] or received [Rx]). NOTE: The Link LEDs indicate transmission of light only, not whether there is data encoded in the optical link. 2 2 1 Tx Rx LINK NOTE: Ensure that the transmitter and connected receiver are the same transmission mode, singlemode (SM) or multimode (MM) and that you use the correct SM or MM fiber cable to connect the devices. LINK a. Receiver OPTICAL Operation After the receiver, the transmitter, and their connected devices are powered up, the system is fully operational. If any problems are encountered, verify that the cables are routed and connected properly and that the display device has a compatible resolution and refresh rate. If problems persist, call the Extron S3 Sales & Technical Support Hotline. See the contact numbers on the last page of this guide for the Extron office nearest you. Indications NOTE: The figure below right is of a receiver. A transmitter has similar indications. Power ( ) LED — Indicates that power is applied to the unit. Video LEDs — Signal LED — Lights on both units when the unit detects an input video signal. VIDEO CONFIG HDCP LED — Lights on both units when the input signal is HDCP encrypted. AUDIO SIGNAL OUTPUT HDCP RETURN IN Audio LEDs — Input LED (transmitter) — Lights when an analog audio or PCM digital audio signal remains above -35 dBV. The LED goes unlit if the audio signal level drops below the threshold for 10 seconds or longer. Output LED (receiver) — Lights when an analog audio or PCM digital audio signal remains above -35 dBV. The LED goes unlit if the audio signal level drops below the threshold for 10 seconds or longer. Return Out LED (transmitter) — Lights when analog audio is present on the transmitter Return Audio Output connector. Return In LED (receiver) — Lights when analog audio is present on the receiver Return Audio Input connector. EDID (Transmitter) EDID SELECT EDID Select rotary switch — Set this switch to one of the positions shown in the table below to select the source of the EDID or a specific resolution. Position 0 — An EDID that has previously been captured from a connected display or manually imported via an SIS command or the Product Configuration Software. Position 1 — The EDID is selected via the Remote or USB port on the transmitter only, using an SIS command or the Extron Product Configuration Software. Position 2 — Use the EDID from the display connected to the receiver. NOTE: EDID from the display connected to the receiver requires connection of both fiber cables. Position 3 — Use the EDID from the display connected to the transmitter loop-through. Positions 4 through E — Specify a resolution. The table at right identifies the resolutions associated with the switch positions. All resolutions are at 60 Hz with the exception of 3840x2160 (E), which is 30 Hz. Position F — No EDID assigned. Pos. Source or resolution 0 User recorded EDID 1 Selected via RS-232 2 Display on Rx output 3 Display on Tx loop-through 4 1280x720 5 1280x800 * 30 Hz Pos. 6 7 8 9 A B Resolution 1366x768 1440x900 1680x1050 1920x1080 1920x1200 2048x1536 Pos. C D E* F Resolution 2048x2160 2560x1600 3840x2160 N/A Remote control See the FOX II T/R DP 4K User Guide, available at www.extron.com, for details on operating and monitoring the transmitter and receiver using either SIS commands or the Extron Product Configuration Software. 3 FOX II T/R DP 4K • Setup Guide (Continued) Application Diagram Extron FOX T DP 4K Fiber Optic Transmitter Extron IPCP Pro 250 IP Link Pro Control Processor IPC P PR O 25 0 Ethernet L I/O DIG M ITA 2 CO X T M 4K DP Tx RS L DIO TS AU L Rx G T MO RE 232 S- Tx Rx G Tx M AR AL R 1 Rx G RTS CTS C Rx 2 C 4 3 2 G AYS REL 1 VOL V ER POW X 12V MA --A Tx eBU +V +S G IR/S S -S LAN G S = G 6W OUT G PWR ET RES TCP/IP Network Rx Tx E LINK Tx DIO UT AURN O TU RE R Rx LINK OVER FIBER FO IR -232 1 1 CO AL TIC OP 2 RS-232 R Ethernet AX AM ~ -.- OP e lum ts se Audio RU TH LO r Ch Pre l ne an ne Tu op Lapt te Mu 3 pla 2 y 1 Dis T OR YP PLA 6 5 On 4 Off DIS 9 ber em Dec p Hel re Mosets Pre dio Auntrol Co tem Sys Off er Ent 0 n ree Sc Hz st La 8 7 te Mu om Ro ol ntr Co -60 3 Vo VCR DVD PC 240V 100- 12 r Tune Doc Cam PU IN 15, 201 3- 8 AM 7:5 E ttrxon nEoxr ng hti Lig 50 Extron TLP Pro 720T 4K DisplayPort 4K DisplayPort 7" Table Top TouchLink Pro Touchpanel Up to 30 km (18.75 miles) Singlemode Fiber SM Model Local Monitor Extron XPA 1002 PC 02 A 10 XP S2 G T RIN TPU 2 WI OU AS CL 1 Power Amplifier TE MO RE UTS mA 50 TE /MU 10V VOL INP 2 1 EL LEV STA Y NDB 2 1 1 0Hz , 50-6 1.3A 240V R/ ITE T LIM EC OT PR NAL SIG 0 2 0 100- P 4K RD X L S DIO UT TP AU OU Extron FOX R DP 4K Fiber Optic Receiver 240V 100- AX AM ~ -.- -60 50 Hz R L Rx G M AR AL R Tx Rx G Tx 1 RES ET Rx Tx E T MO RE 232 S- Rx LINK Tx DIO IN AU RN TU RE R LINK OVER FIBER FO IR -232 RS AL TIC OP 2 Audio T OR YP LA P DIS RS-232 4K DisplayPort MO DE L 80 Extron SI 28 Surface-mount Speakers Extron Headquarters +800.633.9876 Inside USA/Canada Only Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +1.714.491.1517 FAX +1.919.850.1001 FAX 4 Extron Europe +800.3987.6673 Inside Europe Only +31.33.453.4040 +31.33.453.4050 FAX Extron Asia +65.6383.4400 +65.6383.4664 FAX Extron Japan +81.3.3511.7655 +81.3.3511.7656 FAX Extron China +86.21.3760.1568 +86.21.3760.1566 FAX 4K Display Extron Middle East +971.4.299.1800 +971.4.299.1880 FAX Extron Korea +82.2.3444.1571 +82.2.3444.1575 FAX Extron India 1800.3070.3777 (Inside India Only) +91.80.3055.3777 +91.80.3055.3737 FAX © 2016 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 68-2540-50 Rev. B 01 16