Transcript
Specifications Input AC Input Voltage: Input Frequency: Output Operational Output Power: Output Voltage: Connection:
120Vac/240Vac 50/60Hz 7W (ONT load) 12Vdc Nominal (Battery voltage upon loss of AC) F-type coaxial (Corning Gilbert RG6 or smaller)
Battery Type: 7.2Ah AGM Recharge Time 18 Hours to 90% Battery Backup Provides approximately 20 Hours of backup at 3.5W* Provides approximately 12 Hours of backup at 7W* *Based on new, fully-charged battery Physical Housing Size (in/mm): Weight (lb./kg): Battery 7.2Ah (lb./kg):
8.75W x 7.75H x 3.0D/222W x 197H x 76D 1.3/0.59 5.7/2.6
Visual Status Indicators Green LED: Green LED Flashing: Red LED: Red LED flashing:
AC mode Battery mode Replace battery Battery missing/Low battery
Audible Status Indicators Loss of Input Power: Low Battery: Replace Battery: Push Buttons Silence Alarm: Battery Emergency Use: Agency Compliance
Suppresses the audible alarm for 24 hours Accesses reserve battery capacity NRTL certified to UL/CSA 60950-1 Ed. 2 (ITE) (Pollution Degree 2, Overvoltage Category II), LPS Output, SELV
Safety (other): Safety (EU):
IEC 60950-1:2005 + National Deviations. (Pollution Degree 2, Overvoltage Category II), LPS Output, SELV CE, EN 60950-1:2006
EMC (US):
FCC part 15 subpart b, Class B
EMC (EU):
CE, EN 55022:2006 (CISPER 22) (Emissions) Class B, EN 55024:1998 +A1 +A2 (Immunity), EN 61000-3-2:2006 (Harmonics), EN 61000-3-3 (Fluctuations and Flicker) CE, RoHS compliant -20°C to +50°C (-4°F to +122°F)
Operating Temperature: 0°C to 40°C (32°F to 104°F) Note: Operating temperatures based on AX-LONGBAT-7 Humidity: 5% to 95% Elevation Operation (max.): 0 to 10,000ft (0 to 3,000m) — derate 2°C per 1,000ft (305m) above 6,000ft (1830m) Elevation Storage (max.): Battery Storage:
50,000ft (15,000m) -20°C to +40°C (-4°F to +104°F) (six months max. storage duration at 25°C / 77°F without a recharge)
Warranty FlexPoint FPR1207-F: Battery:
3-year, repair or replace Contact Alpha Technologies for model-specific warranty coverage
Alpha Technologies 3767 Alpha Way Bellingham, WA 98226 USA Tel: +1 360 647 2360 Fax: +1 360 671 4936 www.alpha.com Alpha Technologies Ltd. 7700 Riverfront Gate Burnaby, BC, V5J 5M4 CANADA Tel: +1 604 436 5900 Fax: +1 604 436 1233 Due to continuing product improvements, Alpha reserves the right to change specifications without notice. Copyright © 2014 Alpha Technologies, Inc. All rights reserved. Alpha is a registered trademark of Alpha Technologies. 010-344-B0-001 Rev. B (2/2014)
4
FTTx UPS System for ONTs — Model FPR1207-F
Review the drawings and illustrations contained in this guide before proceeding. For additional details on installation and operation, visit www.alpha.com and download a copy of the FlexPointTM FPR1207-F/FPR1207-F Technical Manual. The FPR1207-F is an optical network terminal (ONT) power supply that provides 7W of primary and standby power at 12Vdc. The FPR1207-F converts customer supplied 120Vac/240Vac, 50/60Hz outlet voltage to a 12Vdc output. Status reporting is provided locally via audible and visual alarms. Standby power is provided by one 7.2Ah battery installed in the FPR1207-F. Upon loss of AC power the FPR1207-F supports the load until the battery reaches 25% remaining usable capacity. At that point, the FPR1207-F enters sleep mode preserving capacity for emergency calls. Pressing the Emergency Use button accesses the remaining capacity.
ONT
Single, one second beep Single 0.5 second beep every 15 seconds at 25% SOC Double beep every 15 minutes
Safety (US):
Environment Storage Temperature:
FlexPoint™ FPR1207-F Quick Start Guide
FlexPointTM FPR1207-F
Up to 6' (1.8m)
Network Area
Customer Area
FPR1207-F RG6 or similar home coax cabling. Up to 50' (15m)
Fig. 1, System Block Diagram
CAUTION! The power supply cord is used as the main disconnect device. Verify the socket/outlet is located/ installed near the equipment and is easily accessible.
Installing and Connecting the FPR1207-F 1. Unpack and inspect the FPR1207-F. 2. The unit is designed for use in a sheltered environment protected from rain and snow. Its operating temperature range is 0°C to 40°C / 32°F to 104°F (ambient). Install the unit near an AC outlet. 3. Remove battery compartment door by pressing tab and opening door. Remove the door and set aside until the installation process is complete. 4. Determine the necessary cable length to provide appropriate service loops between the FPR1207-F, the ONT, and the outlet. Plug the line cord into the receptacle on the back of the FPR1207-F. Do not plug the FPR1207-F into an AC outlet until the last step of the installation procedure. 5. Mount the FPR1207-F to the wall with #12 fasteners or equivalent, using the keyholes for easy mounting. For applications (with 7.2Ah battery only) with higher seismic requirements, use the round holes in the back of the unit for direct fastening to a stud or other structural feature. 6. Connect Coax cable to F-type connector. Torque to between 4.1 in-lbs and 6.1 in-lbs. 010-344-B0-001 Rev. B (2/2014)
1
WARNING! Risk of explosion if battery is replaced by an incorrect type. Recycle spent batteries in accordance with local regulations. .200" 2
7.8" 198mm
Ø.380"
Battery Installation / Replacement Procedure 1. (Failed Battery Replacement) For units with Alpha part number 010-344-20-001 (note that the final three digits in bold are the key indicator), disconnect the AC line cord from the AC power outlet before beginning battery replacement. 2. (Battery Replacement / Failed Battery Replacement) Disconnect the wire harness to the battery.
3.0" 76mm
Ø.250" 1
3. Connect the wire harness to the charged battery (a fully charged battery reads about 13Vdc). 4. Install the battery in the cradle as shown in Fig. 8. The locking tab secures it in place.
2.5" 63.5mm
5. Replace the battery compartment door. To replace the front cover, align the hinges with the hinge sockets and press them in with the door perpendicular with the main housing. Rotate the door closed until the closure door latches.
2
6. Plug the FPR1207-F into an AC power outlet. The Green LED should light.
2.4" 61mm
1
7. Verify the unit is functioning properly by unplugging the unit. The alarm should sound for one second and the Green LED should flash. The unit will be running on standby battery power.
1.3" 33mm
8. Re-plug the FPR1207-F into an AC power outlet. The unit is ready to be placed into service.
8.7" 221mm
1 2
3.0" 76mm
Mounting holes for customer-supplied #12 hardware or equivalent "Keyhole" slots for easy mounting
Fig. 2, FPR1207-F Dimensions (in/mm) (Viewed From Back)
Fig. 6, 7.2Ah Battery
Fig. 8, Battery Installed
Fig. 7, Battery Compartment, With Wire Harness
FPR1207-F Controls and Indicators
R
VISUAL STATUS INDICATORS
Battery Emergency Use
1
Silence Alarm
Silence Alarm
Battery Emergency Use
1
2 2
Green LED: Green LED flashing: Red LED: Red LED flashing:
AC mode Battery mode Replace battery Battery missing / Low battery
1
2
Remove cover to access silence alarm and battery emergency use buttons.
Fig. 3, RF Cable Connection 2
Fig. 4, Push Button Detail
Fig. 5, AC Power Cord Connection (Viewed From Back) 010-344-B0-001 Rev. B (2/2014)
010-344-B0-001 Rev. B (2/2014)
3