Preview only show first 10 pages with watermark. For full document please download

Fresh Air Breathe Easy

   EMBED


Share

Transcript

Fresh Aireasy Breathe R410 a Air Conditioners Residential and commercial R410 a Airco Branded Products The Airco brand dates back to 1949 when it was first launched into the local market. This brand has always been used to supply OEM products from some of the best comfort solutions manufacturers in the world. Today this proud tradition continues as the brand was re established and is currently extensively utilised on various comfort product ranges. Only the best producers of these respective ranges are selected to supply our brand into the market. Product and Production Quality Management ISO 9001 & ISO14001 certified. Strategic partnership with UL since 2002 Five laboratories awarded WTDP by UL since 2002 Strategic partnership with TUV and LGA ITS RoHS Compliance Scheme Awarded 6 Sigma Implementation Comfort Fresco Tech 1 2 1 3 4 2 5 6 7 8 3 9 10 4 Silver Ion Filter Cold Catalyst Filter Vitamin C Filter Bio Filter Silver Ions kill bacteria and prevent bacterial activity. Eliminates formaldehyde and other volatile organic compounds (VOCs) as well as harmful gasses and odours. The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress. Contains specialised biological enzymes and HEPA. It filters out small dust particles, bacteria, fungi and microbes, eliminating bacteria by dissolving their cell walls. 5 6 7 8 Compound Filter 3M HAF Filter Negative Ion Filter Plasma Dust Collector Combines the functions of two or three different filters to meet various needs simultaneously. This open hole structure is charged electrostatically to ensure maximum air flow and minimum pressure drops. Releases negative ions to purify the air, and sterilise bacteria, reducing tiredness. Generates a high voltage electrostatic zone, to absorb and eliminate dust, smoke and pollen particles. 9 10 Super Ionizer & Ionizer Releases negative ions, eliminate odours, dust, smoke and pollen particles to give you fresh and healthy air. 2 Features Reliability Heating Belt (Outdoor) Self-Diagnosis Function Valve Protection Cover (Optional on certain models) If abnormal operations or part failures, are detected, the microcomputer of the unit will automatically switch off to protect the system. The error or protection code will be displayed on the indoor unit. This cover protects the valves during transportation. It also prevents the condensed water on the valve from dripping. With a PTC heating belt fitted onto the base plate of the outdoor unit, accumlated rain, snow or defrosted water is avoided. Anti-Rust Cabinet The cabinet is treated to eliminate rust. Powerful Dehumidification Automatically adjusts humidity to a suitable level when in operation. Low Ambient Cooling If the unit has a Low Ambient Kit installed it can operate in temperatures as low as -15ºC for cooling. Refrigerant Leakage Detection When the outdoor unit detects a refrigerant leak, the indoor unit will alarm. Two Speed Outdoor Fan Motor Gold Fin With a two speed outdoor fan motor, the temperature ranges of the outdoor unit are increased in both heating and cooling operations. The Gold hydrophilic condenser improves heating efficiency by accelerating the defrosting process. The unique anticorrosive golden coating on the condenser can withstand salty air, rain and other corrosive elements. Bluefin Coils (Optional on certain models) Bluefin Coils are offered on all outdoors. Health Silver Ion Filter Bio Filter Negative Ion Filter Fresh Air Silver Ions kill bacteria and prevent their activity. The Bio Filter consists of a specialised biological enzymes and an Eco Filter. The Eco Filter catches very small airborne dust particles and neurilities bacteria, fungi and microbes. Biological enzymes kill bacteria by dissolving their cell walls thus eliminating the problem of re-pollution. Releases negative ions which purifies air, sterilises bacteria and reduces tiredness. Fresh air intake makes air quality healthier and more comfortable. Plasma Dust Collector Self-Cleaning The Plasma Dust Collector generates a high voltage electrostatic field. The air passing through this zone is converted to plasma, and 95% of the dust, smoke and pollen particles are attracted to the electrostatic filter. When this function is activated, the indoor unit operates in fan-only mode with a low fan speed. During this period the condensed water will remove the dust on the evaporator fins. The unit then turns to heating mode with a low fan speed which dries the inside of indoor unit. Finally it turns to fan-only mode and blows away the wet air. The whole process cleans the inside of indoor unit preventing the breeding of bacteria. Cold Catalyst Filter Eliminates formaldehyde and other volatile organic compounds (VOCs) as well as harmful gasses and odours. Vitamin C Filter (Optional on certain models) The Vitamin C filter fills the air with vitamin C, which softens the skin and reduces stress. The lifetime of the Vitamin C filter is approximately two years. Compound Filter Combines functions of two or three different filters to meet various needs simultaneously. 3M HAF Filter Super Ionizer & Ionizer This open hole structure is charged electrostatically to ensure maximum air flow and minimum pressure drops. Releases negative ions, eliminates odours, dust, smoke and pollen particles giving you fresh and healthy air. Multi-Bend Evaporator Sleep Mode Intelligent Eye Detector lW Standby Within the confined space of the indoor unit, the multi-bend evaporator helps increase the heat exchange surface for improved efficiency. Sleep Mode automatically increases (cooling) or decreases (heating) at 1°C per hour for the first two hours, then holds steady for the next 5 hours, after that it will switch off. This characteristic is energy saving and increases comfort during operation at night. (Optional on certain models) Intelligent on-off technology enables Airco products to automatically enter energysaving mode when on standby, cutting energy consumption from 4-5W to 1W which accounts to a 5O% saving on the indoor operation. Energy Saving With the built-in infrared sensor, the indoor unit detects human movement. The unit will turn off 30 minutes after you have left the room and automatically switch on when you return, helping save energy. 3 Features Super Silent Airflow Multi Indoor Fan Speeds With up to 12 indoor fan speeds, a more comfortable air flow is possible. 0.5W Standby Technology controls the airflow volume and capacity output and together with the large diameter cross-flow fan the noise level of the indoor unit is lowered. Short-cut function Intelligent on-off technology enables Airco products to automatically enter energysaving mode when on standby. Cutting energy consumption from 5W to 0.5W which amounts to a 90% saving. Preset all functions (like temperature, operation mode, fan speed and other). Every time you press the “SHORT CUT” button, the unit will run under the mode that you recorded. You don’t need to reset the parameters after they are adjusted by other users. Horizontal & Vertical Auto Swing Low Noise Airflow System The design of the large louvres, with a wide swing angle range, guides the cool or warm air to every corner of the room. Without decreasing airflow and capacity, a large diameter cross flow fan can bring down the indoor unit noise level by reducing the fan speed. Because the density of cold and warm air varies, in cooling mode the indoor unit blows out horizontally and in heating mode it blows out vertically. This technology makes the room temperature more consistent and comfortable during the operation. Temperature Compensation Condensate Disposal Comfort 8°C Heating In heating operation, the pre-set temperature of the air conditioner can be as low as 8ºC, which keeps the room temperature steady at 8ºC for in winter. Follow Me (Optional on certain models) A temperature sensor is built into the remote control. When you are close to the remote control, the unit will automatically change the setting on the unit to ensure comfortable temperature just like the air conditioner is following you. Anti-Cold-Air (Heat Pump Only) On starting up the unit, the fan speed is regulated automatically from the lowest setting to the preset level, according to the temperature in the evaporator. This function prevents cold air blowing out at the beginning of the operation, avoiding discomfort. 4 Independent Dehumidification The individual dehumidification mode dehumidifies the room efficiently, but does not lower the temperature as significantly as cooling operation. Turbo Operation This function maximises the heating or cooling output, resulting in a rapid response to temperature change. Different installation heights effects the temperature picked up by the sensor (on the floor). The installer can change the jumping wire combination on the indoor PCB to compensate for this deviation. Multi Indoor Fan Speeds With up to 12 indoor fan speeds, more variation in airflow is possible. Two-Direction Airflow Slinger-ring condensate disposal, enhancing cooling performance. PTC Heater (Optional on certain models) With a built-in PTC device, the heating operation is more powerful even in extreme cold. 360º Air Flow Panel Auto Swing The 360° air outlet makes equal, fast and wide-range cooling possible. Distributes air to a wider area by moving horizontal flaps automatically. Features Convenience Mono & Multi Compatibility Washable Filter A washable filter makes it easier to clean. The indoor unit is compatible with both mono and multi inverter systems. This is convenient for warehouse and stock administration. Louvre Position Memory Function On restarting the unit, the angle of the horizontal louvre automatically moves to the same position as it was previously set at. Auto-Restart If the air conditioner stops due to a power cut, it will automatically restart with the previous function settings. Convenient Handle Ergonomical handle makes carrying the unit easier and convenient. Wired Controller Sliding Chassis (Optional on certain models) (Optional on certain models) The wired controller can be fixed onto the wall to avoid being misplaced. It is recommended for commercial use. The whole refrigerant system can be slided out, which makes installation easier and safer. Transparent Water Level Indication Clearly shows the water level and indicates when draining is required. Optional Filter More functional filter choices will enhance the efficiency of the unit. Built-in Drain Pump Slim Design The minimised dimensions of the unit, allows for an easier and more flexible installation and improved aesthetics . Timer The timer can be set to start and stop at any point within a 24 hour period. Installation Kit Cassettes have a drain pump which can extract up to 750mm of condensed water. Cleanable Panel The front panel of the indoor unit is easy to detach for cleaning. 2 Way Piping Connection Piping and drainage hoses can be connected on either side of the indoor unit. (Optional on certain models) Designed to assit with the installation of the system. Remote Control ON / OFF Mode Setting Temperature Setting Short Cut Function AUTO/COOL/DRY/HEAT/FAN Fan Speed Setting Timer Setting HIGH/MED/LOW/AUTO Sleep Mode/Fresh Air Flow SWING/DIRECT Turbo / Self Clean LED Display / Follow me 5 Model Code (Nomenclature) Residential A S 9A I - 12 H R F N1 - Q D2 F I Airco A I Unit Type S Connect Type Multi Type Omit Single Type S P D W F O Split Wall-mounted Portable Dehumidifier Window Floor Standing Outdoor 9A Product Series 11P lA y 11M Premier Series Alps Series Y Series Oasis Series 12 Capacity Air Conditioner: Cooling Capacity (xlOOOBtu/h) Dehumidifier: Moisture Removal Volume (L/day) H C H A E Function Code Cooling only Heat Pump Heat Pump with Electric Heater Cooling & Electric Heater Light Commercial (Indoor Unit) A A C C T H U F D A B C D 24 C D - 24 H R F N1 Airco Product Category Cassette Type Duct Type High Static Pressure Duct Type Ceiling & Floor Type Console C H 6 Q R W R F Control Mode Wire Control Mechanical Control Electric Control Remote Control F Q N1 Refirgerant Nl N2 N3 Omit R410A R407C R134a R22 Capacity Q R F F L H Q W Power Supply (V-Hz-Ph) 220-240V~, 50Hz, 1Phase 380-420V~, 50Hz, 3Phase Function Code Ionizer Low Ambient Kit Fresh Air Quicker Connect Outdoor Power Supply Light Commercial (Outdoor Unit) A - 36 H F N1 - Q Airco Outdoor Unit Universal Power Code EER Code D2 AO-A9 EER 1.0-1.9 BO-B9 EER 2.0-2.9 C0-C9 EER 3.0-3.9 DO-D9 EER 4.0-4.9 O U Refrigerant Power Supply 220-240V~,50Hz, 1Phase 380-420Vx~, 50Hz, 3Phase 380V~, 50Hz, 3Phase Full DC Inverter DC Inverter AC Inverter ON/OFF Inverter Code N1 Q R S Inverter Type Universal Outdoor Unit F Full DC Inverter D DC Inverter Omit ON/OFF Power Code F D I Omit OU Nl R410A Omit R22 Cooling only Cooling & Heating W M E R Q Wire Control Remote Control 1st Design 2nd Design 3rd Design 4th Design Function Code Control Mode A OU B Designed Range Cooling Capacity (x1000Btu/h) H - R B Designed Range A B C D 1st Design 2nd Design 3rd Design 4th Design 36 Capacity Cooling Capacity (x1000Btu/h) H Function Code C H Cooling only Cooling & Heating F Inverter Type F Full DC Inverter D DC Inverter Omit ON/OFF N1 Refrigerant Nl R410A Omit R22 Q Q R Power Code Power Supply (V-Hz-Ph) 220-240V~,50Hz, 1Phase 380-420V~,50Hz, 3Phase Product Range Light Commercial Series ON/OFF Super Slim Cassette 18K 24K 36K 48K 60K 3rd generation ceiling & floor Split 18K 24K 36K48K 60K Cassette cover up to 18000 Btm Duct 12K 18K 24K 30K 36K 48K 60K High Static Presure Duct 18K 24K 36K48K 60K Series ON/OFF R 7K 9K 12K 18K 21K 24K, 30K G 36K 7 Compact Cassette 3600 Air Outlet Panel Fresh Air Intake 3600 air outlet makes equal, fast and wide-range cooling. Fresh air fulfills air quality healthier and more comfortable. Compact Design E-box Inside The body size of this unit is The E-box is simply and safely built 570mmx570mmx260mm, and panel inside the indoor unit. This integrated size is 647mmx647mmx50mm.lt can design proVidas a more compact body be installed in one standard ceiling size and ease of installation. And the tile (600Wx600D), which can save maintenance of the E-box is simple, by installation time and proVida an ease of openning the return air grille. installation. 8 Compact Cassette Features Optional Standard Auto Defrosting Air Flow Panel Auto Restart Function Sleep Mode Anti-Cold Air Function Built-in Drain Pump Wired Controller Independent Dehumidification Low Ambient Cooling Specifications – Compact Cassette: Single (ON/OFF) ACA-12HRN1 Power supply Cooling Heating Indoor fan motor Indoor coil ACA-18HRN1 V-ph-Hz 220~240-1-50 220~240-1-50 Capacity Btu/h 12000 18000 Input W 1190 2150 Current A 5,45 9,3 EER W/W 2,96 2,45 Capacity Btu/h 13000 19500 Input W 1180 1837 Current A 5,4 8,30 COP W/W 3,23 3,11 Model YDK15-6P YDK37-4P Qty 1 1 Input W 47.1/31.1/26.9 80/65/46 Capacitor uF 1.5UF/450V 2UF/400-450V Speed(Hi/Med/Lo) r/min 780/540/430 1000/875/710 1 2 Number of rows Tube pitch(a) x row pitch(b) mm 21×13.37 21×13.37 Fin spacing mm 1,3 1,3 Hydrophilic aluminum Hydrophilic aluminum Fin type Tube outside dia. & type mm ø7, Inner grooved tube ø7, Inner grooved tube Coil (LxWxH) mm 1380×210×13.37 1370×210×26.74 2 4 Number of circuits Indoor air flow (Hi/Mid/Lo) m3/h 680/600/400 800/710/560 Indoor noise level (sound pressure) (Hi/Mid/Lo) dB(A) 41/38/35 44/41/38 Throttle type / / Dimension (WxDxH)(body) mm 570x570x260 570x570x260 Packing (WxDxH)(body) mm 655x655x290 655x655x290 Dimension (WxDxH)(panel) mm 647x647x50 647x647x50 Packing (WxDxH)(panel) mm 715x715x123 715x715x123 Net/Gross weight(body) kg 16/20 19/21 Net/Gross weight(panel) kg 2.5/4.5 2.5/4.5 Design pressure MPa 4.2/1.5 4.2/1.5 Drainage water pipe diameter mm ODΦ25 ODΦ25 Refrigerant piping mm ø6.35/ø12.7(1/4"/1/2") ø6.35/ø12.7(1/4"/1/2") RG51Q/BGE RG51Q/BGE Indoor unit Liquid side/Gas side Controller Operation temperature Cooling ºC 17~32 17~32 Heating ºCΦ 0~30 0~30 Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 9 Cassette Touch Screen Wired Controller (optional) Lifting Easy-Clean & 3600 Air flow Panel Standard high-end touch screen wired The removeable lifting panel makes the controller with failure indication. A clean process much easier. And with more user friendly interface is possible. the 3600 flow system, distributing comfort to every corner of the room. This unit is only 205mm in height, an improvement over the 230mm height Twin Combination of the conventional model. The units can be installed as Twin systems: one outdoor unit can connect with two indoor units. The indoor units can be combined in any of the different available ratings. Reserved Remote on-off and Alarm Ports Optional on certain models If the airflow direction needs to be Remote On/Off With the reserved changed as a result of an altered room ports, a remote switch can be easily layout or due to the mode selected, the connected to realise remote control. air direction of each vane can be set The built in PCB output alarm facility independently using the wired remote makes setting up an external alarm controller. light or gauge possible. 10 Independent Vane Control Cassette Features Optional Standard Auto Defrosting Sleep Mode Timer Low Ambient Cooling Auto Restart Function Slim Design Wide-angle Air flow Wired Controller Anti-Cold Air Function Fashion Design Air Flow Panel Optional Colour Panels LED Display Independent Dehumidification Built-in Drain Pump Specifications – Cassette (ON/OFF) Model ACA-24HRN1 Power supply Cooling Heating Indoor fan motor Capacity ACA-48HRN1 ACA-60HRN1 V-ph-Hz 220~240-1-50 220~240-1-50 380~420-3-50 380~420-3-50 Btu/h 24000 36000 48000 60000 Input W 2475 3970 5515 6685 Current A 12,5 18,17 9,52 11,55 EER W/W 2,87 2,66 2,55 2,63 Capacity Btu/h 26000 40000 49500 60000 Input W 2428 4070 5410 5920 Current A 11,8 19,67 9,34 10,22 COP W/W 3,13 2,88 2,68 2,97 Model YDK80-6E YDK90-6E YDK90-6E YDK90-6E Qty 1 1 1 1 110/100/90 147/125/110 147/125/110 147/125/110 Input Indoor coil ACA-36HRN1 w Capacitor uF 3.5UF/450V 3.5UF/450V 3.5UF/450V 3.5UF/450V Speed(hi/mi/lo) r/min 670/550/400 770/640/550 770/640/550 770/640/550 2 2 2 3 Tube pitch(a)x row pitch(b) mm 21x13.37 21x13.37 21x13.37 21x13.37 Fin spacing mm 1,5 1,4 1,5 1,5 Hydrophilic aluminum Hydrophilic aluminium Hydrophilic aluminium Hydrophilic aluminium Number of rows Fin type (code) Tube outside dia.and type mm ø7,Inner grooved tube ø7,inner grooved tube ø7,inner grooved tube ø7, inner groove tube Coil (LxWxH) mm 1990×168×26.74 1990x252x26.74 1990x252x26.74 2080x252x40.11 8 8 12 12 Indoor air flow (Hi/Med/Lo) m3/h 1327/1114/871 1545/1354/1187 1545/1354/1187 1800/1480/1280 Sound level (sound pressure) dB(A) 48/45/39 50/46/42 51/47/43 51/47/42 / / / / 840x840x230 840x840x300 840x840x300 840x840x300 Number of circuits Throttle type Indoor unit Dimension (Wx DxH)(body) Packing (WxDxH)(body) mm 900x900x250 900x900x320 900x900x320 900x900x320 Dimension (WxDxH)(panel) mm 950x950x55 950x950x55 950x950x55 950x950x55 Packing (WxDxH)(panel) mm 1035x1035x90 1035x1035x90 1035x1035x90 1035x1035x90 Net/Gross weight(body) kg 24/30 28/32 28.6/32.6 32/36 Net/Gross weight(panel) Design pressure Drainage water pipe dia. Refrigerant piping mm kg 5/8 5/8 5/8 5/8 MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 mm ODø32 ODø32 ODø32 ODø32 Liquid side/ Gas side mm ø9.52/ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") RG51Q1/BGE RG51Q1/BGE RG51Q1/BGE RG51Q1/BGE Cooling ºC 17~32 17~32 17~32 17~32 Heating ºC 0~30 0~30 0~30 0~30 Controller Operation temperature Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 11 3rd generation ceiling & floor Swing Torsion Angles 3600 air outlet makes equal, fast and wide-range cooling possible. Flexible Installation The unit can be installed horizontally on the ceiling or vertically against a wall. Compact Design Fresh Air Intake Fresh air improves air quality. More than 60% parts and assemblies (such as fan wheel, plastic cases, metal parts and etc) are universal for 3 different bodies, which makes the production and maintenance easier. 12 3rd generation ceiling & floor Specifications – Ceiling & Floor (ON/OFF) Indoor Unit AUE-18HRN1-Q Outdoor Unit AOU-18HRN1-Q AUE-24HRN1-Q AOU-24HRN1-Q AUE-36HRN1-Q AOU-36HRN1-Q AUE-36HRN1-R AOU-36HRN1-R AUE-48HRN1-Q AUE-60HRN1-R AOU-48HRN1-Q AOUA-60HRN1-R Capacity Cooling Capacity Heating Capacity Btu/h 18000 24000 36000 36000 48000 55000 kW 5.3 7.1 10.5 10.5 14.0 16.1 Btu/h 20000 26000 40000 40000 52000 65000 kW 6.0 7.6 12.0 12.0 15.2 19.1 Electrical parts Power Supply V~, Hz, Ph 220-240, 50, 1 220-240, 50, 1 220-240, 50, 1 380-415, 50, 3 380-41S, 50, 3 380-415, 50, 3 Power Input (kW) Cooling 1726 2423 4180 4180 5360 6370 Heating 1863 2415 3985 3985 4980 6145 Performance EER W/W 3.07 2.93 2.51 2.51 2.61 2.51 COP W/W 3.22 3.15 3.01 3.01 3.01 3.01 Air Flow Volume m3/h 1200/1000/900 1200/1000/900 1900/1700/1500 1900/1700/15OO 1900/1700/1500 2500/2100/1800 Noise Level (dB(A)) Hi/Med/Low 51/46/42 51/46/42 53/48/44 53/48/44 53/48/44 54/49/46 Dimension & Weight & Piping Size Net Dimension (mm) WxHxD 1068x235x675 1068x235x675 1285x235x675 1285x235x675 1285x235x675 1650x235x675 Net Weight kg 22.4 25 29 29 31 39 Packing Dimension (mm) WxHxD 114Sx313x755 1145x313x755 1360x313x755 1360x313x755 1360x313x755 1725x313x755 Gross Weight kg 26.6 30 36 36 36 45 Piping Size (mm) Liquid Ø6.4 Ø9.5 Ø9.5 Ø9.5 Ø9.5 Ø9.5 Gas Ø12.7 Ø15.9 Ø19.0 Ø19.0 Ø19.0 Ø19.0 Drainage ODØ25.00 Ø25.00 Ø25.00 Ø25.00 Ø025 OOØ25 Applicable Area & Stuffing Quantity Applicable Area m2 21-35 28-47 42-70 42-70 S6-93 64-107 Stuffing Quantity (Set) 20’/40’/40’HQ 62/129/151 59/122/143 32/67/79 32/67/79 30/63/74 27/57/67 Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 13 Duct Return Air Ways Fresh Air Built-in Drain Pump (optional) Air inlet from back standard and from bottom optional. The size of the plate from Optional on certain models The drain pump can lift the condensing bottom and flange from back is the same, it’s easy for installer to change the air Fresh air to introduce ambient air. water up to 750mm upmost inlet from back to bottom. Twin Combination Optional on certain models The units can be installed as dual systems one outdoor unit can connect with two indoor units. The indoor units can be combined in any of the different available ratings. 14 Duct Features Optional Standard Timer Two way drainage Low Ambient Cooling Auto Restart Function Wired Controller Independent Dehumidification Built-in Drain Pump Auto Defrosting Sleep Mode Anti-Cold Air Function Specifications – High Static Pressure Duct Power supply Cooling Heating Indoor fan motor V- Ph-Hz AHC-36HWN1 AHC-48HWN1 AHC-60HWN1 220~240-1-50 380~420-3-50 380~420-3-50 Capacity Btu/h 24000 36000 48000 60000 Input W 2830 4010 5800 6630 Current A 13,30 18,35 9,20 9,50 EER W/W 2,5 2,63 2,43 2,65 Capacity Btu/h 26000 39000 52000 65000 Input W 2450 3680 4800 5300 Current A 11,80 16,84 8,20 8,90 COP W/W 3,11 3,11 3,17 3,59 Model YDK100-4X-1 YDK200-4F YDK360-4F YSK400-4C Qty 1 1 1 1 220/205/190 500/460/345 630/570/435 930/740/592 15uF/370-450V Input Indoor coil AHC-24HWN1 220~240-1-50 W Capacitor uF/ V 12uF/450V 15uF/370-450V 15uF/370-450V Speed (Hi/Mid/Lo) r/min 940/900/870 1060/980/820 1210/1135/960 1080/920/790 2 3 4 3 mm 25.4 x22 25.4x22 25.4x22 25.4x22 mm 1,5 1,6 1,6 1,6 Number of rows Tube pitch(a)×row pitch(b) Fin spacing Fin type Hydrophilic aluminium Tube outside dia. & type mm Coil (LxWxH) mm Number of circuits Indoor air flow (Hi/Med/Lo) (No duct) m3/h Indoor external static pressure (Hi) Indoor noise level (Hi/Med/Lo) 7 7 996x355.6x66 7 1800/1670/1450 2400/2200/2000 3000/2700/2200 4000/3750/3100 Pa 100 150 160 160 48/46/44 56/54/50 58/56/51 57/53/50 / / / / Dimension (W×D×H) mm 856x691x400 856x691x400 856x691x400 1200x691x400 Packing (W×D×H) mm 1090x768x440 1090x768x440 1090x768x440 1436x768x440 Net/Gross weight kg 41/47 47/53.5 52/57 63/70 Design pressure MPa Liquid side/ Gas side mm Controller Operation temperature 700x355.6x88 3 dB(A) Drainage water pipe dia Refrigerant piping 700x355.6x66 (Under Standard Static Throttle type Indoor unit ø9.52,inner grooved tube 700x356x44 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 ODø25 ODø25 ODø25 ODø25 ø9.52ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") ø9.52/ø19(3/8"/3/4") KJR-10B/DP(T)-E KJR-10B/DP(T)-E KJR-10B/DP(T)-E KJR-10B/DP(T)-E Cooling ºC 17~32 17~32 17~32 17~32 Heating ºC 0~30 0~30 0~30 0~30 Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 15 R Series Turbo Mode Sleep Mode With this function, the air conditioner This function enables the unit to will maximize the output of cooling or automatically increase (cooling) or heating capacity, make the room cool decrease (heating) 1ºC per hour for the down or heat up rapidly, and attain the first two hours, then hold steady for desired temperature in the shortest the next 5 hours, after that the unit time. will stop operation. It can maintain the optimal temperature and save energy 16 R Series Features Optional Standard Auto Restart Function Sleep Mode Ionizer Vitamin C Filter Cold Catalyst Filter Turbo Mode Heating Belt (Outdoor) Silver Ion Filter LED Display Temp Compensation Low Ambient Cooling Bio Filter Gold Fin Specifications – R Series ASR-09HRN1 Power supply Cooling Heating ASR-12HRN1 ASR-18HRN1 ASR-24HRN1 ASR-30HRN1 ASG-36HRN1 1Ph, 220-240V~, 3Ph, 380-420V~, 50Hz 50Hz 50Hz 24000 30000 36000 2920 3650 3625 Ph-V-Hz 1Ph, 220-240V~, 50Hz 220-240V~50Hz, 1Ph 220-240V~50Hz, 1Ph 1Ph, 220-240V~, Capacity Btu/h 9000 12000 18000 Input W 820 1345 2020 Rated current A 3.7 6.3 9,3 13.1 16.4 7.3 EER W/W 3.21 2,61 2.61 2.41 2.41 2.91 Capacity Btu/h 9500 12000 18000 24000 30000 36000 Input W 770 1170 1725 2335 2920 3350 Rated current A 3.4 5.8 8,0 10.6 13.2 6.8 COP W/W 3.61 3,01 3.06 3,01 3,01 3.11 Moisture Removal L/h 1.0 1,1 1.6 2,1 2.6 3.6 Max. input W 1100 1800 2500 3200 3850 4300 Max. current A 5.5 8.0 12.0 16 20 7.5 Starting current A 21.7 22,2 25.9 36,8 36,8 53 PA103M1C-4DZDE2 PA130G1C-4DZ PA185M2C-4FT2 PA215X2CS-4KU1 PA240X2CS-4KU1 NN37YCAMT consumption Compressor Indoor fan motor Model Type ROTARY ROTARY ROTARY ROTARY ROTARY ROTARY Brand GMCC GMCC GMCC GMCC GMCC MITSUBISHI Model RPG13H Brand Indoor coil Welling Input W Capacitor uF Speed (Hi/Mi/Lo) r/min Number of rows Tube pitch(a)xrow mm 34 1.2 RPG13H RPG25 YDK36-4C(A) YDK36-4C(A) YDK50-4E Welling Welling Welling Welling Welling 34 55 67/58/50 67/58/50 76/67/54 -- 1.5 3 3 3 1220 / 1000 / 850 1250/1080/1000 1220 / 1100 / 850 1210/1120/1020 1210/1120/1020 1260/1170/1000 2 2 2 2 2 2 20x11.28 21x13.37 21x13.37 21x13.37 21x13.37 21x13.37 1.3 1,3 1.3 1,3 1.4 1,3 pitch(b) Fin spacing mm Fin type (code) Hydrophilic aluminium Hydrophilic aluminium Tube outer dia. & type mm Coil LxHxW mm Number of circuits ø6,innergroove tube ø7,innergroove tube 540x240x22.56 538x252x26.74 769x273x26.74 799x336x26.74 2397x357x26.72 965x420x26.74 2 2 3 4 4 6 Indoor air flow (Hi/Mi/Lo) m3/h 480/370/300 480/410/380 720/650/500 1000/930/840 1100/1020/930 1300/1200/1050 Indoor noise level (Hi/Mi/Lo) dB(A) 38/33/29 39/35/33 46/43/37 46/43/40 49/46/43 50/47/44 Indoor unit Dimension (WxDxH) mm 710x189x250 710x189x250 930x198x275 1036x230x315 1036x230x315 1250x230x325 Packing (WxDxH) mm 775x260x324 775x260x324 1015x265x350 1135x435x315 1135x435x315 1345x430x335 Net/Gross weight Kg 7 / 9.5 7 / 8.5 11.5 / 14.5 13/18 13.5/18 18/23 17 R Series ASR-09HRN1 Outdoor fan motor Model YDK24-6T(B) Brand Input Outdoor coil W ASR-12HRN1 ASR-18HRN1 ASR-24HRN1 ASR-30HRN1 ASG-36HRN1 YDK24-6(B) YDK36-6 YDK48-6H(A) YDK75-6D(B) YDK75-6C Welling Welling Welling Welling Welling Welling 70 77,3 70 110 170 162 Capacitor uF 3.0 2,5 2.5 3 5.0 5 Speed r/min 815 860 900 890 875 860 1 1 1.6 2 2 2 mm 21x13.37 21x13.37 21x13.37 21x13.37 21x13.37 25.4x22 1.4 1,4 1.5 1.4 1.4 1.7 Number of rows Tube pitch(a)x row pitch(b) Fin spacing mm Fin type (code) Hydrophilic aluminium Tube outside dia.& type mm ø7, innergroove tube Coil (LxHxW) mm Number of circuits ø9.52, innergroove tube 694*504*13.37 598x504x13.37 769+474x504x13.37 658x546x26.74 760x546x26.74 761x813x44 1 2 4 4 4 4 Outdoor air flow m3/h 1650 1900 2000 2300 2500 3500 Outdoor noise level dB(A) 54 55 59 57 62 62 Outdoor unit Dimension (WxDxH) mm 700x240x540 700x240x540 780x250x540 760x285x590 820x330x595 900x315x860 Packing (WxDxH) mm 815x325x580 815x325x580 910x335x585 887x355x645 940x415x645 1043x395x915 Net/Gross weight Refrigerant type Design pressure Refrigerant piping Liquid side/ Kg 24.5 / 26.5 24.5 / 26.5 32.5 / 34.5 43.5/47 44/48 72/76 g R410A/620g R410A/630g R410A/1150g R410A/1400g R410A/1600g R410A/2450g MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 mm(inch) ø6.35/ ø6.35/ ø6.35/ ø9.52/ ø9.52/ ø9.52/ Gas side ø9.52(1/4"/3/8") ø12.7(1/4"/1/2") ø12.7(1/4"/1/2") ø15.9(3/8"/5/8") ø15.9(3/8"/5/8") ø15.9(3/8"/5/8") Max. refrigerant pipe(L) m 20 20 20 25 25 25 Max. difference in level m Connection wiring 8 8 8 10 10 10 1.5 (Optional) 1.5 (Optional ) 1.5 (Optional) 2.5 (Optional) 2.5(Optional) ----- Plug type 1.0x3 / VDE 1.5x3 / VDE 1.5x3 2.5x3/--- 2.5x3/--- ----- Thermostat type Remote Control Remote Control Remote Control Remote control Remote control Remote control Operation temp Application area Qty’per Indoor(cooling/heating) ºC 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 Outdoor(cooling/heating) ºC 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 m2 13-22 18-29 23-39 31-51 35-58 47-78 136/280/314 136/280/314 103/221/250 75/156/191 69/149/165 42/92/105 20’/40’/40'HQ Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 18 Universal Outdoor Units 12k Btu/h 18k Btu/h 24k Btu/h 36k Btu/h 48k, 60k Btu/h Specifications – Single (ON/OFF) Outdoor Unit Power supply V-ph-Hz AOU-12HN1 AOU-18HN1 AOU-24HN1 AOU-36HN1 AOU-48HN1 220~240-1-50 220~240-1-50 220~240-1-50 220~240-1-50 380~420-3-50 AOUA-60HN1 380~420-3-50 Max. input consumption W 1740 2950 3450 4950 6500 7500 Max. input current A 8,5 15 18 30 11 12,6 Compressor Outdoor fan motor Model PA140G1C-4FT1 PA225M2CS-4KU2 PA290G2CS-4MU1 C-SBN301H5D C-SBN373H8D C-SBN453H8D Type Rotary Rotary Rotary Scroll Scroll Scroll Brand GMCC GMCC GMCC Sanyo Sanyo Sanyo Model YDK24-6F(B) YDK48-6H(A) YDK100-6D YDK190-6D(B) YDK190-6D(B) YDK65-6F(B) Qty Input Outdoor coil W 1 1 1 1 1 2 63 110 167 290 290 162 Capacitor μF 2.5UF/450V 3uF/450V 5UF/450V 10uF/450V 10uF/450V (3.5UF/450V)X2 Speed r/min 800 890 900 830 830 765 1 2 2 Tube pitch(a) x row pitch(b) mm 22×19.05 21x13.37 21x13.37 Fin spacing mm 1,4 1,4 1,4 Number of rows 1,5 21x13.37 1,4 Fin type 2 22x19.05 1,6 2 22x19.05 1,6 Hydrophilic aluminum Tube outside dia. & type mm Coil (LxWxH) mm Number of circuits ø7.94,inner grooved tube 737×506×19.05 660x546x26.74 785x651x26.74 890x903x26.74 887x880x38.1 837x1100x38.1 2 4 4 6 10 4 Outdoor air flow (Max.) m3/h 1800 2400 2700 5500 6000 6500 Outdoor noise level (sound pressure) dB(A) 55 58 59 61 63 63 Capillary Capillary Capillary Capillary Capillary Capillary mm 780x250x547 762x282x593 842x324x695 990x354x966 990x354x966 900x340x1167 Throttle type Outdoor unit Refrigerant type/Qty Dimension (WxDxH) Packing (WxDxH) mm 910x335x575 887x355x645 965x395x755 1120x435x1100 1120x435x1100 1032x443x1307 Net/Gross weight kg 28/30 37/39 48/54.5 86/98 90/95 96/105.5 R410A R410A R410A R410A R410A R410A Charged volume kg 0,96 1,4 1,8 2.6 2,8 3.2 MPa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 Liquid side/ Gas side mm (inch) Type Design pressure Refrigerant piping ø6.35/ø12.7(1/4"/1/2") ø9.52/ø15.9(3/8"/5/8") ø9.52/ø19(3/8"/3/4") Max. pipe length m 15 25 25 30 50 50 Max. difference in level m 8 15 15 20 25 25 Ambient temperature Cooling ºC 18~43 18~43 18~43 18~43 18~43 18~43 Heating ºC -7~24 -7~24 -7~24 -7~24 -7~24 -7Φ24 Note: 1. The above design and specifications are subject to change without prior notice for product improvemnet. 2. The noise level data reflects the level in an anechoic chamber. 19 Fresh AirEasy Breathe Air Conditioners Residential and commercial R22 R Series Specifications – ASR ASR-09HR Power supply Cooling Heating Ph-V-Hz ASR-12HR ASR-18HR ASR-24HR ASR-30HR 1Ph, 220-240V~, 50Hz 220-240V~ 50Hz, 1Ph 1Ph, 220-240V~, 50Hz 220-240V~ 50Hz, 1Ph 220-240V~ 50Hz, 1Ph Capacity Btu/h 9000 12000 18000 24000 30000 Input W 1010 1345 2060 2695 3370 Rated current A 4.6 6.3 9.4 12.0 15,1 EER W/W 2.61 2,61 2,56 2,61 2,61 Capacity Btu/h 9500 12000 18000 24000 30000 Input W 920 1200 1595 2335 3140 Rated current A 4.2 5.9 7,8 11 14,2 COP W/W 3.03 2,93 3.31 3,01 2.80 Moisture Removal L/h 1.0 1,1 1,6 2,2 2.6 Max. input consumption W 1450 1600 2250 3200 3600 Max. current A 7.6 9 11,6 16 19.2 Starting current A 18.2 29.6 43.1 54 63.4 Model PH165G1C-4DZDE1 PH215G1C-4DZ1 PH290X2C-4FT1 PH370G2CS-4MU1 PH465X3CS-4MUA Type ROTARY ROTARY ROTARY ROTARY ROTARY Brand GMCC GMCC GMCC GMCC GMCC Model RPG13H RPG13H RPG25 YDK36-4C(A) YDK36-4L(A) Brand Welling Welling Welling Welling Welling Compressor Indoor fan motor Indoor coil Input W 34 34 55 70/54/50 69/50/38 Capacitor uF 1.2 -- -- 2 3.0 Speed (Hi/Mi/Lo) r/min 1220/1000/850 1250/1080/1000 1220/1100/850 1210/1020/950 1290/1100/930 2 2 2 2 2 Number of rows Tube pitch(a)xrow pitch(b) mm 20x11.28 21x13.37 21x13.37 21x13.37 21x13.37 Fin spacing 1.3 1,5 1,3 1,4 1.3 mm Fin type (code) Hydrophilic aluminium Tube outside dia. & type mm ø6,innergroove tube ø7,innergroove tube Coil (LxHxW) mm 540x240x22.56 538x252x26.74 769x273x26.74 799x357x26.74 799x336x26.74 2 2 3 4 4 Number of circuits Indoor air flow (Hi/Mi/Lo) m3/h 500/400/350 520/450/420 760/690/620 980/830/770 1050/900/760 Indoor noise level (Hi/Mi/Lo) dB(A) 38/33/30 40/37/35 45/43/36 45/40/37 50/45/42 Indoor unit 2 Dimension (WxDxH) mm 710x189x250 710x189x250 930x198x275 1036x230x315 1036x230x315 Packing (WxDxH) mm 775x260x324 775x260x324 1015x265x350 1135x435x315 1135x435x315 Net/Gross weight Kg 7 / 8.5 7/8.5 10/12 13/17.5 13.5 / 16.5 R Series Features Optional Standard Auto Restart Function Sleep Mode Ionizer Vitamin C Filter Cold Catalyst Filter Turbo Mode Heating Belt (Outdoor) Silver Ion Filter LED Display Temp Compensation Low Ambient Cooling Bio Filter Gold Fin ASR-09HR Outdoor fan motor Outdoor coil ASR-12HR ASR-18HR ASR-24HR ASR-30HR Model YDK25-4(B) YDK24-6(B) YDK36-6 YDK75-6D(B) YDK100-6D Brand Welling Welling Welling Welling Welling Input W 61 77,3 70 170 168.7 Capacitor uF 2 2,5 2.5 5.0 5.0 Speed r/min Number of rows 965 / -- / -- 860 / -- / -- 900 870 / -- / -- 900 1 1 2 2 2 Tube pitch(a)xrow pitch(b) mm 21x13.37 22x19.05 21x13.37 21x13.37 21x13.37 Fin spacing 1.3 1,4 1,5 1,4 1.4 mm Fin type (code) Hydrophilic aluminium Tube outside dia.and type mm ø7, innergroove tube Coil (LxHxW) mm 676x399x13.37 593x484x19.05 754x504x26.74 760x546x26.74 779x651x26.74 2 2 4 4 8 Number of circuits Outdoor air flow m3/h 1300 1900 1500 2500 2700 Outdoor noise level dB(A) 53 54 56 61 62 Dimension (WxDxH) mm 685x260x430 700x240x540 780x250x540 820x330x595 845x320x700 Packing (WxDxH) mm 795x345x495 815x325x580 910x335x585 940x415x645 965x395x755 Outdoor unit Kg 22 / 25 24 / 27.5 34 / 36 47/50.5 55 / 58 Refrigerant type Net/Gross weight g R22/500g R22/670g R22/1260g R22/1800g R22/1900g Design pressure MPa 2.6/1.0 2.6/1.0 2.6/1.0 2.6/1.0 2.6/1.0 Refrigerant piping Liquid side/Gas side mm(inch) ø6.35/ø9.52(1/4"/3/8") ø6.35/ø12.7(1/4"/1/2") ø6.35/ø12.7(1/4"/1/2") ø9.52/ø15.9(3/8"/5/8") ø9.52/ø15.9(3/8"/5/8") Max. refg pipe length m 10 10 18 20 20 Max. difference in level m 5 5 5 10 10 Connection wiring 1.0(Optional) 1.5(Optional) 1.5(Optional) 1.0(Optional) 1.0(Optional) Plug type 1.0x3/ VDE 1.5x3 / VDE 1.5x3 2.5x3 -- Thermostat type Remote Control Remote Control Remote Control Remote Control Remote Control Operation temperature Application area Qty ‘per 20’/40’/40' HQ Indoor (cooling/heating) ºC 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 Outdoor (cooling/heating) ºC 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 m2 13-22 13-22 26-44 31-51 35-58 144/300/336 136/280/314 103/221/250 69/149/165 65/140/152 Note: 1. The above design and specifications are subject to change without prior notice for product improvement. 2. The noise level data reflects the level in an anechoic chamber. 3 R Series Specifications – ASG ASG-36HR Power supply Cooling Heating ASG-36HR Ph-V-Hz 1Ph, 220-240V~, 50Hz Capacity Btu/h 36000 Brand Input W 4380 Input W 165 Rated current A 19.6 Capacitor uF 3 EER W/W 2.41 Speed r/min Capacity Btu/h 38000 Input W 4100 Tube pitch(a)xrow pitch(b) mm Rated current A 18.5 Fin spacing COP W/W 2.72 Fin type (code) Outdoor fan motor Outdoor coil Model YDK53-6H(B) Welling Number of rows mm Moisture Removal L/h 3.6 Tube outside dia.and type mm W 5800 Coil (LxHxW) mm Max. current A 32 Number of circuits Indoor coil ø9.52, innergroove tube 761x813x44 4 114 Outdoor air flow m3/h 3500 ZR47K3-PFJ-522 Outdoor noise level dB(A) 63 Type SCROLL Outdoor unit Dimension (WxDxH) mm 900x315x860 Brand Copeland Packing (WxDxH) mm 1043x395x915 Model YDK50-4E Net/Gross weight Kg 82/87 Brand Welling g R22/2450g A Refrigerant type Input W 76/67/54 Design pressure Capacitor uF 3 Refrigerant piping Speed (Hi/Mi/Lo) r/min Number of rows MPa 2.6/1.0 Liquid side/Gas side mm(inch) ø9.52/ø15.9(3/8"/5/8") 1260/1150/990 Max. refg pipe length m 25 2 Max. difference in level m 10 Tube pitch(a)xrow pitch(b) mm 21x13.37 Connection wiring ----- Fin spacing 1.3 Plug type ----- Hydrophilic aluminium Thermostat type Operation temperature mm Fin type (code) Tube outside dia. & type mm ø7, innergroove tube Coil (LxHxW) mm 965x420x26.74 6 Application area Indoor air flow (Hi/Mi/Lo) m3/h 1350/1200/1050 Qty ‘per 20’/40’/40' HQ Indoor noise level (Hi/Mi/Lo) dB(A) 52/49/46 Number of circuits Indoor unit 1.7 Model Starting current Indoor fan motor 25.4x22 Hydrophilic aluminium Max. input consumption Compressor 820 2 Dimension (WxDxH) mm 1250x230x325 Packing (WxDxH) mm 1345x430x335 Net/Gross weight Kg 18/23 Remote control Indoor (cooling/heating) ºC Outdoor (cooling/heating) ºC m2 17~32/0~30 18~43/-7~24 51-85 42/92/105 Airco was founded in 1949 and - since then - we have been striving continually to develop environmentally friendly, energy efficient and cost effective comfort and process cooling solutions for our customers. We endeavor to supply the correct product for the application maintaining the highest possible quality standards. Our dedicated team of people are ready to serve and assist. Head Office (Johannesburg) 0861 COOLING www.airco.co.za 4 Address: 39 Webber Street, Selby Postal: PO Box 61441 Marshalltown 2107 Tel: 011 493 0169 Fax: 011 493 7660 [email protected] Hot Water Heat pump water heaters Residential and commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating systems. It surpasses coal, electric, gas and solar water heating, offering a better solution for energy saving and environmental protection. Electrical Power • E nergy saving, cost saving Helps you save up to 75% of the water heating costs that you spend on conventional water heaters. Maintenance costs are also very low. 1kW • A  ll-weather operation Reliable hot water delivery day and night under all types of weather conditions (Operating range -10ºC to 43ºC). Heat Recovery • E nvironmental protection Reducing CO2 emissions, by using environmentally friendly refrigerants. Heating Output 3.6kW 4.6kW • F ull range of HPWH products Product range covers household, Commercial and Industrial HPWH. Airco Heat Pump Water Heater Concept of Airco Water Heating Air Source Heat Pump Water Heater, represents the latest water heating technology, and works on the principle of a refrigerant Reversed Carnot Cycling, drawing heat out of atmosphere (air) and discharging it into the water. Storage Tank Heat Pump Unit 1 Electricity Kitchen Water Heating Hot Water Compressor Heatexchanger Lavatory Applying heat pump technology to produce hot water using energy absorbed from environment. The efficiency can be more than 450%. 2 Outdoor Air Evaporator Principle Sketch Refrigerant Cycle Bath/ Shower 1+2=3 Expansion Valve Pump Cold Water Power consumption comparison Figures based on the same conditions to heat water from 15ºC to 55ºC Airco HPWH Gas Water Heater Electric Water Heater Boiler Solar Water Heater Energy Resource Air, electricity Gas Electricity Diesel Oil Solar, electricity Transfer Factor 860kcal/kW.h 24000kcal/m3 860kcal/kW.h 10200kcal/kg 860kcal/kW.h Average Efficiency 4.6 0.8 0.95 0.7 2.7 (1/3 weather need Auxilliary Heater) Consumption 10kW.h 2.08m3 48.9kW.h 5.6 kg 17.5kW.h Running Cost 7.7 50.2 36.7 55.3 12.8 Merit/Demerit Green, safe, energy saving, environmentally friendly and easy to install. High risk: danger of fire, explosion. Have CO2 emissions, etc. Risk electric shock emission, High risk: danger of oil Difficult installation, large etc. leakage, fire, explosion. Have area required, and effective CO2 emissions, etc. water tank volume is limited. Energy use comparison Life cycle costing comparison 18 Units of energy used per day 16 14 12 Airco HPWH Initial Cost Gas WH Initial Cost Electric WH Initial Cost Gas 10 Running Cost Over 10 Year s Running Cost Over 10 Year s Electric 8 6 4 Heat pump Boiler Initial Cost 2 Solar Solar WH Initial Cost 0 Jan Feb Mar Apr May Jun Jul Jul Aug Sep Oct Nov Running Cost Over 10 Year s Running Cost Over 10 Year s Running Cost Over 10 Year s Dec Features • Can operate 24/7 in all conditions, day and night (if required) • Compact design, space saving, small footprint • Produces hot water up to 60 ºC, controlled and maintained to setpoint • Versatile installation • Hot water is being produced whilst hot water is being used • Units can be mounted distant to demand area, on brackets or on plinth • Unit “pays for itself” with proven savings on monthly electricity bill. If rates increase, payback period is reduced. • Reduced operating costs – heats water cheaper and faster than electricity • Energy efficient – COP values over 4:0 versus 1:1 on electric heating • Environmentally friendly – recovers free energy and use ozone friendly gases • Reliable and low maintenance • Easy to operate – self diagnostic, set point specific control Residential / light commercial Self contained / integrated water heater Household water-heating model selection Model Application ARSJ-15/190 RDN3 4-5 people ARSJ-35/300 RDN3 5-6 people 190 litre storage, 1.5kW 190/300 litre storage, 3.5kW Hot Water Hot Water Recommendation: Water Temp.: 50ºC Shower: 45-55L/person Bath: 90-110L/person Cold Water Inlet Cold Water Inlet Specifications approved Airco Model Number ARSJ-15/190 RDN3 ARSJ-35/300 RDN3 Heating Capacity - Heat Pump kW 1.5 kW 3.5 kW Input Power - Economy mode watts 500 watts 970 watts Rated Current - Economy mode Amps 3.8 Amps 4.2 Amps Ambient Temperature - Economy mode °C 5 ~ 43°C 5 ~ 43°C COP values @ 20°C - Economy mode W/W 3,0 3,6 Auxillary Heating E-Heater mode kW 2 kW 3 kW Input Power E-Heater mode Amps 6.8 Amps 13 Amps Ambient temperature E Heater mode °C - 30 ~ 43° C - 30 ~ 43° C Power Supply v / Ph / Hz 220 ~ 240 / 1 / 50 Water Tank Volume litres 190 litres 300 litres Water Outlet Temperature °C 38 ~ 70°C 38 ~ 70°C Default temperature °C 65°C 65°C Max operating pressure of tank KPA 700 kpa 700 kpa Noise level dB(A) 48 48 Water inlet pipe & water outlet & PTvalve inch / DN 3/4" / DN20 3/4" / DN20 Drain pipe / Condensate drain inch / DN 3/4" / DN20 3/4" / DN20 Refrigerant - type / quantity R134a R134a / 0.73 kg R134a / 1.2 kg Protection devices HP, Temp & Power Overload , Earth Leakage Modes of operation Economy & E-Heater Econ, E-Heat & Hybrid Nett Weight / Operating Weight kg 86 kg / 257 kg 123 kg / 405 kg Dimensions Ø x h mm Ø 560 x 1580 mm Ø 650 x 1920 mm Packed dimensions w x d x h mm 729 x 699 x 1660 mm 745 x 775 x 2030 mm Notes: The test conditions: outdoor temp. 20/15ºC (DB/WB). The operation range: -7ºC~43ºC. Unit ARSJ 15/190 RDN3 uses R134A refridgerant. The specification may be changed for product improvement, please refer to the nameplate. Residential / light commercial Split cycle heating type Household water-heating model selection Model Application KRS-35B 2-4 people KRS-50B 4-5 people KRS-72B 4-5 people Hot Water Water Piping Cold Water Inlet Recommendation: Water Temp.: 50ºC Shower: 45-55L/person Bath: 90-110L/person Optional Water Tank or existing geyser Specifications approved Airco Model Number KRS-35 B KRS-50 B KRS - 72 B Heating Capacity kW 3.5 kW 5.0 kW 7.2 kW Input Power W 830 / 1200w 1200/1740w 1720/2490w Rated Current Amps 3.97 / 5.8 A 5.8 / 8.3 A 8.23 / 11.9 A 4.2 / 2.91 4.16 / 2.87 4.18 / 2.89 COP Power Supply v / Ph / Hz Hot Water Yield l/hr Operating Temp Range 220 ~240 V / 1 Ph / 50Hz 75 l/hr 107 l/hr 155l/hr -10 ~ 43 -10 ~ 43 -10 ~ 43 Refrigerant mm R410a R410a R410a Water outlet Temp ˚C 25 ~ 60 25 ~ 60 25 ~ 60 55 55 55 52 dB(A) 53 dB(A) 54dB(A) 3/4" 3/4" 3/4" Default Temperature Noise Level 1 Metre Distance dB(A) Water pipe sizes. In & out Protection Devices Hp, LP, Overtemp, +-Voltage, De-Ice Circulation Pump Yes/No Yes Yes Yes Digital Control Back-up Batt Yes Yes Yes Timer Settings 2 2 2 Modes Timer Auto/ Timer Auto/ Timer Auto/ Timer Nett Unit Weight kg 40kg 55kg 65kg Unit Dimesions HxWxD 493 x 750 x 264 545 x 935 x 282 620 x 1002 x 302 Test Conditions WB/DB 20/15 20/15 20/15 CE/CB CE/CB CE/CB Certifications Airco Split type Heat-Pumps use the latest technology to heat water, conserve energy and protect the environment. They are energy efficient, cost effective and can be retrofitted to existing geysers or optional storage vessels. Heat-Pumps are reliable and deliver hot water under all weather conditions to pre-set conditions. Airco Heat-Pumps are environmentally friendly, offer quiet operation (two speed fan), and use ozone friendly refrigerants. Split type Heat-Pumps incorporate Wilo high efficiency, in line, hot water circulation pumps. Wired, wall mounted mult-functional control, with self diagnostic features, allows one to set (and monitor) all modes. Auto re-start, de-ice sensor and factory set parameters for easy operation. Double walled tube-in-tube heat exchanger offers excellent heat transfer capabilities, with no chance of refrigerant leakage or water contamination. Commercial High temperature direct heating type Specification Model Units KRS 100 E KRS 200 E KRS 300 E KRS 400 E KRS 450 E KRS 630 E Heating Capacity kW 10.5 19 30 38 45 63 Input Power kW 2.55 4.55 7.2 9.2 10.8 16 Rated Current Amps 12.46 7.83 12 15.84 18.6 27.5 4.12 4.18 4.17 4.13 4.17 3.94 COP Power Supply V/Ph/Hz 220 ~240 V/1 Ph/50hz Hot Water Yield l/hr 226 408 -10º ~ 43º -10º ~ 43º -10º ~ 43º ºC 25 ~ 60 ºC 25 ~ 60 ºC 25 ~ 60 ºC Operating Temp Range Water outlet temperature Default Temperature dB(A) Circuits Water inlet connection In/Out Protection Devices HP Control - Self Diagnostic Yes/No Timing Cycles 817 967 1354 -10º ~ 43 deg -10º ~ 43º -10º ~ 43º 25 ~ 60 deg C 25 ~ 60 ºC 25 ~ 60 ºC R410a R410a R410a R410a R410a R410a 55 57 58 60 61 1 1 2 2 2 3 1", 1" 1", 1" 1:1/2" , 1:1/2" 1:1/2", 1:1/2" 1:1/2", 1:1/2" 2", 2" Yes Yes HP, LP, Temp Old, +- Volt, Phase, Defrost Yes Yes Yes Yes 1 Modes of Operation Recommended flow 645 55 Refrigerant Noise level 1 meter 380 ~ 415 V / 3 Ph / 50 Hz litres/hr Circulation pump built in Auto/timer Auto/timer Auto/timer Auto/timer Auto/timer Auto/timer 2300 4100 6400 8200 9700 13500 No Pressure drop through system Kpa 40 50 55 55 55 55 Nett Weight Kg 87 119 236 249 268 428 Unit Dimensions HxWxD 765 x 752 x 690 765 x 752 x 690 950 x 1450 x 702 1060 x 1450 x 702 1260 x 1450 x 702 1290 x 2150 x 765 Test Conditions WB/DB 20/15 20/15 20/15 20/15 20/15 20/15 Water inlet/supply ºC 15/55 ºC 15/55 ºC 15/55 ºC 15/ 55 ºC 15/55 ºC 15/55 ºC Commercial High temperature direct heating type Heat pump intelligent wired controller • Auto mode: set on/off signal to master unit, and all the units will start. • Manual mode: under "Manual mode", water will be heated to the set temperature, and then return to "Auto mode". • Timer function. • Water outlet temperature is adjustable. • Auto restart function, in the event of power failure. • Monitor and display the system running status of system. Self diagnostic in event of malfunction. LCD display Up Mode selection On / Off Down Parameter setting Clock and timer Airco was founded in 1949 and - since then - we have been striving continually to develop environmentally friendly, energy efficient and cost effective comfort and process cooling solutions for our customers. We endeavor to supply the correct product for the application maintaining the highest possible quality standards. Our dedicated team of people are ready to serve and assist. Head Office (Johannesburg) 0861 COOLING www.airco.co.za Address: 39 Webber Street, Selby Postal: PO Box 61441 Marshalltown 2107 Tel: 011 493 0169 Fax: 011 493 7660 [email protected] 1/2013