Preview only show first 10 pages with watermark. For full document please download

Fresh Water Unit Fws-v200 Technical Data Sheet

   EMBED


Share

Transcript

TECHNICAL DATA SHEET Fresh water unit FWS-V200 FWS-V200-14 with circulation ‘ FWS-V200-14 without circulation FWS-V200-20 with circulation ‘ FWS-V200-20 without circulation FWS-V200-30 with circulation ‘ FWS-V200-30 without circulation ‘ Equipment example with process water circulation E B C D A ‘ Hydraulic diagram A B C D E Drinking water from the line Domestic hot water home Heating flow, primary Heating return, primary Process water circulation 1 2 3 4 5 6 7 8 9 10 Plate heat exchanger GBS 240H-14, GBS 240H-20, GBS 240H-30 Pump Backflow preventer Shut-off ball valves Sensor Ventilation Controller Safety group Free flow valve Free flow valve with backflow preventer Delta Systemtechnik GmbH | 1 Technical Data Sheet ‘ FWS-V200 ‘ Technical data Materials Fittings Seal Thermal insulation Heat exchanger Pipeline Sanitary: CW602N, CW617N Heating: CW617N, CW614N OHA-Press EPP Plates: 1.4404, Solder: copper or nickel or screwed exchanger 1.4401 Sanitary Max. operating pressure PN 10 Domestic hot water temperature 60 °C Domestic cold water temperature 10 °C Domestic hot water output 63 kW at FWS-V200-14 and 75 °C Heating flow, primary up to 87 kW at FWS-V200-20 and 75 °C Heating flow, primary up to 115 kW at FWS-V200-30 and 75 °C Heating flow, primary Domestic hot water tap amount approx. 18 l/min (FWS-V200-14), up to approx. 25 l/min (FWS-V200-20), up to approx. 35 l/min (FWS-V200-30) Min. pre-pressure 1,5 bar Heating Max. operating pressure Max. operating temperature Min. operating temperature PN 6 85 °C 5 °C Electrical Power connection Current consumption Power consumption 230 V / 50 Hz up to 2,6 A up to 0,34 kW Dimensions Width x height x depth Weight Article no. 102 040 9 102 041 0 102 041 1 102 041 2 102 041 3 102 041 4 450 x 700 x 282,7 mm approx. 15,5 kg without circulation approx. 18 kg with circulation FWS-V200-14 with circulation, 18 l/min FWS-V200-14 without circulation, 18 l/min FWS-V200-20 with circulation, bis 25 l/min FWS-V200-20 without circulation, bis 25 l/min FWS-V200-30 with circulation, bis 35 l/min FWS-V200-30 without circulation, bis 35 l/min Controller › Microprocess-controlled controller with rotary knob for hot water setting › Volume flow sensor in the cold water inlet for cold water, hot water and heating flow › Recirculating pump UPS 15-60 › Optional: circulation with recirculating pump UPS 15-30B and check valve and DVGW shut-off ball valve 2 | Delta Systemtechnik GmbH ‘ We reserve the right to make technical modifications ‘ We do not assume any liability for mistakes and printing errors ‘ Version: 28.05.15 ‘ All older versions invalid ‘ Pressure losses FWS-V200-14 Cold water side (secondary) Pressure loss bar A: Hot water pump delivery head Maximum output range Residual delivery head Pressure loss bar Hot water side (primary) B: Pressure loss FWS-Eco-Mini Hot water requirement litres/h Tap output litre/min The difference between curve A and B is the recirculating pump‘s residual delivery head in FWS-V200; this is required to overcome the pipeline resistance between the buffer storage and hot water heater. ‘ Output curves and return temperatures FWS-V200-14 Heating flow temperature Cold water heating by 50 K (10 - 60°C) Hot water requirement litres/h Hot water requirement litres/h Cold water heating by 35 K (10 - 45°C) Heating flow temperature Tap output litre/min Tap output litre/min Return temperature °C Return temperature °C Tap output litre/min Heating flow temperature Heating flow temperature Tap output litre/min Delta Systemtechnik GmbH | 3 Technical Data Sheet ‘ FWS-V200 ‘ Pressure losses FWS-V200-20 Cold water side (secondary) Hot water side (primary) 0,40 0,30 0,20 1,20 ▲ 1,00 Druckverlust bar Pressure loss bar Restförderhöhe Residual delivery head 0,50 1,40 Maximum Maximaler Leistungsbereich output range A: Hot water pump delivery head A: Förderhöhe Heizwasserpumpe 0,80 ▲ Pressure loss Druckverlust barbar 0,60 0,60 0,40 0,10 0,20 B: Druckverlust Pressure loss FWS-Eco-Mini B: WFS Eco 0,00 500 1000 0,00 1500 5 Hot water requirement litres/h 10 15 20 25 30 35 Tap output litre/min 40 45 The difference between curve A and B is the recirculating pump‘s residual delivery head in FWS-V200; this is required to overcome the pipeline resistance between the buffer storage and hot water heater. ‘ Output curves and return temperatures FWS-V200-20 Cold water heating by 35°K (10 - 45°C) 55°C 60°C 65°C Cold water heating by 50°K (10 - 60°C) 70°C 65°C 75°C 1600 75°C 1400 1400 1200 1200 1000 1000 800 600 400 200 Heating flow temperature 0 5 10 15 20 25 30 35 40 800 600 400 200 Heating flow temperature 0 5 45 10 Tap output litre/min 15 20 25 Tap output litre/min 30 40 65°C 25 Rücklauftemperatur °C 50°C 55°C 60°C Return temperature °C 70°C 1600 Heizwasserbedarf Liter/h Hot water requirement litres/h 50°C 65°C 20 70°C 75°C 15 Heating flow temperature 10 5 10 15 20 25 30 Tap output litre/min 4 | Delta Systemtechnik GmbH 35 40 35 70°C 30 75°C 25 Heating flow temperature 20 45 5 10 15 Tap output litre/min 20 25 ‘ Pressure losses FWS-V200-30 Hot water side (primary) Residual delivery head Restförderhöhe 0,4 0 0,3 0 0,2 0 0,1 0 0,0 0 Maximum Maximaler Leistungsbereich output range ▲ WFS Eco B: Druckverlust Pressure loss FWS-Eco-Mini 1 000 1 500 200 0 500 1,40 Pressure loss barbar Druckverlust A: water pump delivery head A: Hot Förderhöhe Heizwasserpumpe 0,5 0 ▲ Druckverlust bar Pressure loss bar 0,6 0 Cold water side (secondary) 1,20 1,00 0,80 0,60 0,40 0,20 0,00 2 500 5 10 15 Hot water requirement litres/h 20 25 30 35 40 45 50 55 60 Tap output litre/min The difference between curve A and B is the recirculating pump‘s residual delivery head in FWS-V200; this is required to overcome the pipeline resistance between the buffer storage and hot water heater. Cold water heating by 35°K (10 - 45°C) 5 0 °C 55°C Cold water heating by 50°K (10 - 60°C) 65 ° C 7 0 °C 65°C 75°C 7 0 °C 75°C 20 00 15 00 10 00 5 00 Heating flow temperature 0 10 15 30 20 25 30 35 40 45 Tap output litre/min 50 55 60 Heizwasserbedarf Liter/h 20 00 5 15 00 10 00 5 00 Heating flow temperature 0 5 10 15 20 Tap output litre/min 25 30 35 40 5 0 °C 28 5 5 °C 26 Return temperature °C 60°C 6 0 °C 24 6 5 °C 22 35 70°C 20 7 5 °C 18 16 14 12 Heating flow temperature 10 5 10 15 20 25 30 35 40 45 Tap output litre/min 50 55 60 Rücklauftemperatur °C Hot water requirement litres/h ‘ Output curves and return temperatures FWS-V200-30 65°C 7 0 °C 30 7 5 °C 25 Heating flow temperature 20 5 10 15 20 25 30 35 Tap output litre/min Delta Systemtechnik GmbH ‘ Heineckes Feld 9 ‘ 29227 Celle ‘ T +49 (5141) 933 57-0 ‘ F +49 (5141) 933 57-29 ‘ www.deltasystemtechnik.de ‘ [email protected] | 5