Transcript
Introduction
CTC Union Technologies Co., Ltd.
The FRM220-1000E Families are slide in fiber media converters available in a number of
w
different models that also act as line cards for placement in the FRM220 platform Media
w
w
.
c
t
c
u
.
c
o
m
converter chassis. The FRM220-CH01 are stand-alone cases for FRM220 slide-in cards with
User Guide
built-in power supply features. The FRM220-1000ES-2F is a media converter with 2-port 1000Base-X SFP. The FRM220-1000E-2F is a media converter with fixed 2-port 1000Base-X. The data transmission over optical fiber media converter depends on your specific network
Gigabit Ethernet over Fiber Media Converter FRM220-1000E(S)-2F
needs All media converters are available with either multi-mode or single-mode optical transceivers and with connector SC or LC. In single mode, WDM ( Wave Division Multiplexing with SC or LC ) or “Bidi” are also available in 20, 40, 60km reach, which provide the ability to transmit and receive data using only a single optical fiber. When the FRM220-1000E card is placed in the FRM220 rack with SNMP management, the card status, type, and fiber link status can all be displayed. The Fiber media converters give you the freedom to extend your Gigabit Ethernet network cabling distance by allowing connectivity up to 120 kilometers. LED indicators display the status of the converters.
[email protected]
w
w
w
.
c
t
c
u
.
c
o
[email protected]
m
Panel
Specifications
■ Figure #1. Upper Panel of FRM220-1000E(S)-2F
Standards IEEE802.3z 1000Base-SX/LX, Gigabit Standards
1000Base-FX Fiber Optic Connectors 1000ES-2F: Two SFP slot LC connector are provided for optic cable connection. 1000E-2F : Two SC connectors are provided for optic cable connection
Environment Operating -- 0°C – 50°C Storage -- 0°C – 70°C Humidity -- 10 – 90% (non-condensing) 1000ES-2F
1000E-2F
Power Adapter: 12V DC 1A, Built-in AC Power 100~240 V, Built-in DC Power 18~72VDC
Dimensions: (W x D x H) mm 1000E-DC12 : 88 × 160 × 24 1000E-DC48 : 135 × 201 × 35
■ Figure #2 Stand-alone chassis options for FRM220-1000E(S)-2F
AC Jack
AC Jack
Power Switch
Power Switch
DC Jack
Power Switch
1000E-AC : 135 × 201 × 35 1000E-AD : 135 × 201 × 35
Application CPE ( Stand-alone ) to CPE ( Stand-alone )
Power Switch
Ethernet
Ethernet FRM220-1000ES-1+CH01
DC Terminal
1000E-DC12
1000E-AC
[email protected]
1000E-DC48
FRM220-1000E-2F+CH01
FRM220-1000ES-1+CH01
DC Terminal
1000E-AD
w
w
w
.
c
t
c
u
.
c
o
m
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
LED Indicators
Link-Fault-Pass through (LFP) Application Note This media converter incorporates a Fiber Pass Through feature which allows indirect sensing of a Fiber Link Loss via the 10/100/1000 Base-TX UTP connection. Whenever the media converter detects a Link Loss condition on the Receive fiber (Fiber LNK OFF), it disables its UTP transmitter so that a Link Loss condition will be sensed on the receive UTP port. (See the following figure) The link loss can then be sensed and reported by a Network Management agent at the remote UTP port's host equipment.
1000E(S)-2F
PWR
Link 1 Link 2 LFP
This feature has no effect on the media converter's UTP LNK LED, which continues to function normally, independent of the state of the Fiber LNK LED and the UTP transmitter. This feature is enabled by default on all the FIB1-1000 family media converters.
LED
Function
State
Status
PWR
Power indicator
Link1
Fiber link 1
On Off On Off Blinking On Off Blinking On Off
Converter has power Converter has no power Link on No link or the link is faulty Receiving data on the fiber Link on No link or the link is faulty Receiving data on the fiber Link Fault Pass Through enabled Link Fault Pass Through disabled
Link2
Fiber link 2
LFP mode
LFP
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
1000ES-2F DIP Switch :
PWR
UTP
Switch or PC
UTP
TX (OFF)
RX
RX (OFF)
TX
TX
RX
RX
TX
Switch or PC
Fiber Link Fail
Link Fail
Remote Fault
Figure: Fiber Break Responses
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
1000E-2F DIP Switch :
1
PWR
SFP 1
1 Fiber 1
SFP 2
DIP SW
DIP SW
LED
LED Fiber 2
DIP SW Pin 1 -- Link Fault Pass Through (LFP):
DIP SW Pin 1 -- Link Fault Pass Through (LFP):
On : LFP ~ enable Off : LFP ~ disable
On : LFP ~ enable Off : LFP ~ disable
DIP SW Pin 2 ~4 (Reserved)
DIP SW Pin 2 ~4 (Reserved)
Note : ■ The default setting of Dip switch is all set to “OFF” ■ When FRM220-1000E(S)-2F is installed in FRM220 chassis, the SNMP command will takeover the Dip switch setting.
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
Introduction
CTC Union Technologies Co., Ltd.
The FRM220-1000E Families are slide in fiber media converters available in a number of
w
different models that also act as line cards for placement in the FRM220 platform Media
w
w
.
c
t
c
u
.
c
o
m
converter chassis. The FRM220-CH01 are stand-alone cases for FRM220 slide-in cards with
User Guide
built-in power supply features. The FRM220-1000EDS is a media converter with 2-port 10/100/1000Base-T to 2-port 1000Base-X SFP. The FRM220-1000ES-1 is a media converter with 1-port 10/100/1000Base-T to 1-port 1000Base-X SFP. The FRM220-1000E-1 is a media
Gigabit Ethernet over Fiber Media Converter FRM220-1000EDS, FRM220-1000E(S)-1
converter with 1-port 10/100/1000Base-T to 1-port 1000Base-X. The data transmission over optical fiber media converter depends on your specific network needs All media converters are available with either multi-mode or single-mode optical transceivers and with connector SC or LC. In single mode, WDM (Wave Division Multiplexing with SC or LC ) or “Bidi” are also available in 20, 40, 60km reach, which provide the ability to transmit and receive data using only a single optical fiber. When the FRM220-1000E card is placed in the FRM220 rack with SNMP management, the card status, type, fiber link status and UTP link status can all be displayed. For the UTP side, auto-negotiation is default. There units will automatically tailor themselves to convert both half-duplex or full-duplex signals. The Fiber media converters give you the freedom to extend your Ethernet network cabling distance by allowing connectivity up to 120 kilometers. LED indicators display the status of the converters.
[email protected]
w
w
w
.
c
t
c
u
.
c
o
[email protected]
m
Panel
Specifications
■ Figure #1. Upper Panel of FRM220-1000E
Standards IEEE802.3 10Base-T, IEEE802.3u 100Base-TX, IEEE802.3ab 1000Base-T, IEEE802.3z 1000Base-SX/LX, Gigabit Standards
10/100/1000Base-T RJ-45 Connectors 1000EDS : Two RJ45 connectors are provided for UTP cable connection. 1000ES-1 : One RJ45 connector is provided for UTP cable connection 1000E-1 : One RJ45 connector is provided for UTP cable connection All RJ45 ports utilizing auto MDI/MDIX, which allow all UTP connections for both straight and crossover UTP cable.
1000EDS 1000ES-1
RJ-45 Pin
568-A type
568-B type
5 4 3 6 1 2 7 8
Pair1-Tip Pari1-Ring Pair2-Tip Pair2-Ring Pair3-Tip Pair3-Ring Pair4-Tip Pair4-Ring
Pair1-Tip Pair1-Ring Pair3-Tip Pair3-Ring Pair2-Tip Pair2-Ring Pair4-Tip Pair4-Ring
1000E-1
■ Figure #2 Stand-alone rear panel of FRM220-1000E
AC Jack
AC Jack
Power Switch
Power Switch
DC Jack
Power Switch
1000Base-X Fiber Optic Connectors 1000EDS : Two SFP slot LC connectors are provided for optic cable connection. 1000ES-1 : One SFP slot LC connector is provided for optic cable connection 1000E-1 : One SC connector is provided for optic cable connection
Power Switch
Environment Operating -- 0°C – 50°C, Storage -- 0°C – 70°C, Humidity -- 10 – 90% (non-condensing) DC Terminal
DC Terminal
Power Adapter: 12V DC 1A, Built-in AC Power 100~240 V, Built-in DC Power 18~72VDC
1000E-DC12
1000E-AC
1000E-DC48
1000E-AD
Dimensions: (W x D x H) mm 1000E-DC12 : 88 × 160 × 24 1000E-DC48 : 135 × 201 × 35
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
[email protected]
1000E-AC : 135 × 201 × 35 1000E-AD : 135 × 201 × 35 w
w
w
.
c
t
c
u
.
c
o
m
LED Indicators
Link-Fault-Pass Through (LFP) Application Note
1000EDS
PWR
This media converter incorporates a Fiber Pass Through feature which allows indirect sensing of a Fiber Link Loss via the 10/100/1000 Base-TX UTP connection. Whenever the media converter detects a Link Loss condition on the Receive fiber (Fiber LNK OFF), it disables its UTP transmitter so that a Link Loss condition will be sensed on the receive UTP port. (See the following figure) The link loss can then be sensed and reported by a Network Management agent at the remote UTP port's host equipment.
1000E(S)-1
Link 1 Link 2 2CH
PWR
Link 1
LFP
This feature has no effect on the media converter's UTP LNK LED, which continues to function normally, independent of the state of the Fiber LNK LED and the UTP transmitter. This feature is enabled by default on all the FIB1-1000 family media converters.
LED
Function
State
Status
PWR
Power indicator
Link1 Link2
Fiber link 1 Fiber link 2
2CH
Operation mode
LFP
LFP mode
On Off On Off Blinking On Off On Off
Converter has power Converter has no power Link on No link or the link is faulty Receiving data on the fiber 2-channel converter mode 4-port switch mode Link Fault Pass Through enable Link Fault Pass Through disable
UTP
Switch or PC
UTP
TX (OFF)
RX
RX (OFF)
TX
TX
RX
RX
TX
Switch or PC
Fiber Link Fail
Link Fail
Remote Fault
Figure: Fiber Break Responses
Speed
UTP Port LED Indicators
UTP Link
LED
Function
State
Status
Speed
mode display
Link
Ethernet link
Yellow Green Off On Off Blink
1000Base-TX 100Base-TX 10Base-T The UTP link is ok No link or the link is faulty Receiving data on Ethernet
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
[email protected]
w
1000EDS DIP Switch :
1000E(S)-1 DIP Switch :
DIP SW1 for LAN1 and DIP SW2 for LAN2 Setting
DIP SW1 for LAN1 Setting
PWR
w
.
c
t
c
PWR
SFP 1
u
.
c
o
m
o
m
SFP 1
SFP 2
DIP SW1
w
DIP SW
LED
LED
LAN 1
LAN 1
DIP SW2 LAN 2
Pin 1
Pin 2
Pin 3
Pin 4
Off
Off
Off
-
On
Off
Off
Off
On
Off
Function
Pin 1
Pin 2
Pin 3
Pin 4
Function
UTP / N - Way
Off
Off
Off
-
UTP / N - Way
-
UTP 1000Mbps / Full
On
Off
Off
-
UTP 1000Mbps / Full
Off
-
UTP 100Mbps / Full
Off
On
Off
-
UTP 100Mbps / Full
On
On
-
UTP 100Mbps / Half
Off
On
On
-
UTP 100Mbps / Half
On
On
Off
-
UTP 10Mbps / Full
On
On
Off
-
UTP 10Mbps / Full
On
On
On
-
UTP 10Mpbs / Half
On
On
On
-
UTP 10Mpbs / Half
-
-
-
On
LFP On (used in converter mode)
-
-
-
On
LFP On
-
-
-
Off
LFP Off (used in converter mode)
-
-
-
Off
LFP Off
DIP SW1 Pin 5 Operation mode:
Note :
Dip SW1 Pin 5 off: 4-port switch mode (default) Dip SW1 Pin 5 on: 2-channel converter mode Channel one converter: SFP1 to LAN1 Channel two converter: SFP2 to LAN2
■ If all types of slide-in card were installed in FRM220 chassis, The SNMP command will takeover the Dip switch setting.
DIP SW2 Pin 5 (Reserved)
[email protected]
w
w
w
.
c
t
c
u
.
c
o
m
[email protected]
w
w
w
.
c
t
c
u
.
c