ULTRA MINIATURE RELAY SLIM SIGNAL RELAY
FTR-B4 Series
RoHS compliant
n Features Ultra miniature slim type relay for surface mounting Height: 9.3 mm maximum (THT) 10 mm maximum (SMT) Weight: Approximately 1.0 g l UL/CSA recognized l Conforms to Bellcore & FCC part 68, and Telcordia & FCC part 68 l Conforms to UL1950 / CSA 950, IEC 950 / EN60950 spacing and high breakdown voltage Clearance: 1.0mm Creepage: 1.6mm Basic insulation, 150V working voltage, pollution degree 2 l HIGH RELIABILITY Bifurcated contacts l Low power consumption 140 mV (standard), 100 mW (latching) l RoHS compliant since date code: 0430B8 Please see page 8 for more information l
n ORDERING INFORMATION [Example]
FTR-B4 C A 4.5 Z - B 05 (a) (b) (c) (d) (e) (f ) (g)
(a)
Series Name
FTR-B4 Series
(b)
Terminal type
C: Through hole type G: surface mount type S: surface mount type - reduced mounting area
(c)
Operation function
A: standard type B: latching type
(d)
Coil Number
Nominal voltage
(e)
Contact material
Z: gold plated silver alloy
(f )
Relay enclosing direction*
B: standard enclosing direction
(g)
Number of relays per reel*
05: 500 (standard)
Remarks: Actual marking on relay would not carry code FTR and be as below: Ordering code Actual marking Notes: * FTR-B4CA4.5Z → B4CA4.5Z - Only surface mount types (G and S) are applicable - All relays are packaged in tubes unles P/N ends with -B05
FTR-B4 Series n COIL DATA CHART Standard type MODEL
Rated coil Coil resistance voltage (±10%)
Operating voltage
Release voltage*
Rated power consumption
FTR-B4( )A1.5Z
1.5VD C
16. 1 Ω
+1.13V
+0.15V
140mW
FTR-B4( )A003Z
3VD C
64. 3 Ω
+2.25V
+0.3V
140mW
FTR-B4( )A4.5Z
4.5VD C
14 5 Ω
+3.38V
+0.45V
140mW
FTR-B4( )A006Z
6 VD C
25 7 Ω
+4.5V
+0.6V
140mW
FTR-B4( )A009Z
9 VD C
57 9 Ω
+6.75V
+0.9V
140mW
FTR-B4( )A012Z
12VD C
1,02 8 Ω
+9.0V
+1.2V
140mW
FTR-B4( )A024Z
24VD C
2,50 4 Ω
+18.0V
+2.4V
230mW
Set voltage
Release voltage
Rated power consumption
22. 5 Ω
+1.13V
-1.13V
100mW
90 Ω
+2.25V
-2.25V
100mW
* Pulse driven Note: All values in the table are measured at 20˚C. Latching type (1 coil) MODEL
Rated coil Coil resistance voltage (±10%)
FTR-B4 ( )B1.5Z
1.5VD C
FTR-B4 ( )B003Z
3VD C
FTR-B4 ( )B4.5Z
4.5VD C
20 3 Ω
+3.38V
-3.38V
100mW
FTR-B4 ( )B006Z
6 VD C
36 0 Ω
+4.5V
-4.5V
100mW
FTR-B4 ( )B009Z
9 VD C
81 0 Ω
+6.75V
-6.75V
100mW
FTR-B4 ( )B012Z
12VD C
1,44 0 Ω
+9.0V
-9.0V
100mW
FTR-B4 ( )B024Z
24VD C
4,80 0 Ω
+18.0V
-18.0V
120mW
* Pulse driven Note: All values in the table are measured at 20˚C.
FTR-B4 Series n SPECIFICATIONS
Contact
Coil
Time value Insulation
Standard Type
Latching Type
FTR-B4-CA ( ) Z FTR-B4-GA ( ) Z FTR-B4-SA ( ) Z
FTR-B4-CB ( ) Z FTR-B4-GB ( ) Z FTR-B4-SB ( ) Z
Arrangement
2Form C
Contact material
Gold overlay silver alloy
Contact type
Bifurcated contact (cross-bar)
Contact resistance (initial value)
100mΩ maximum at 6VDC 1
Contact rating
30 VDC 1A, 125 VAC 0.3 A (resistive)
Maximum carrying current
1A
Maximum switching power
62.5 VA / 30W
Maximum switching voltage
250 VAC. 220 VDC
Maximum switching current
1A
Maximum switching load*
10m VDC, 0.01mA*
Capacitance
Approximately 0.7 pF (between open contacts) Approximately 0.7 pF (adjacent contacts) Approximately 1.0 pF (between coil and contacts)
Nominal power (at 20°C)
140 mW up to 230 mW
100 mW up to 130 mW
Operate power (at 20°C)
80 mW up to 130 mW
57 mW up to 68 mW
Operating temperature (no frost)
-40°C to +85°C
Operate (at nominal voltage, without bounce) 3ms maximum
3ms maximum (set)
Release (at nominal voltage, without bounce) 3ms maximum
3ms maximum (reset)
Resistance Dielectric strength Surge strength
Minimum 1,000MΩ between open contacts
1,000 VAC 1 minute
between adjacent contacts
1,000 VAC 1 minute
between coil and contacts
1,500 VAC 1 minute
between open contacts
1,500 V (at 10 x 160µs) [FCC Part 68]
between adjacent contacts
1,500 V (at 10 x 160µs) [FCC Part 68]
between coil and contacts
1,500 V (at 10 x 160µs) [FCC Part 68] 2,500 V (at 2 x 10µs) [Bellcore]
Mechanical
50 x 106 operations (at 3 Hz)
Electrical (resistive load)
100 x 103 ops. min. at 1A, 30 VDC (at 0.5 Hz) 100 x 103 ops. min. at 0.3A, 30 VDC (at 0.5 Hz)
Vibration resistance
Misoperation
10 to 55 Hz at double amplitude of 3 mm
Endurance
10 to 55 Hz at double amplitude of 5 mm
Shock resistance
Misoperation
Min. 750 m/s2
Endurance
Min. 1,000 m/s2
Life
Weight
Approximately 1.0 g
*1 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, envir onmental conditions and expected reliability levels.
FTR-B4 Series characteristic data Operation (return time characteristics)
Time (ms)
Time (ms)
4
3
2
5
100
4
80
3
2
Operation time
Set time
1
1
0
0.1
0.2
0
0.3
0.1
Coil Power (W)
60
40 Contact carrying current: 1A 20 Contact carrying current: 0 0.2
0.3
Nominal Voltage Multiplying Factor (%)
80
0.1
0.3
0
2.4
Contact carrying current: 0
2.0
Co cu nta rre ct nt: ca 1A rryi ng
1.8 1.6 1.4 1.2
ltage ng vo
ti Opera il) o (hot c
1.0
ltage ting vo Opera il) o c l o (co
0.8 0.6 0
20
40
80
100
Ambient Temperature (oC)
30
40
50
60
70
80
(maximum applied voltage, operating voltage characteristics) Latching Type
2.4 2.2
Co cu nta rre ct nt ca : 1 rry A ing
2.0 1.8 1.6 1.4 1.2
age
olt ting V Opera ) oil (hot c
1.0
g Voltage Operatin il) co l oo (c
0.8 0.6 0
20
40
60
80
Ambient Temperature
100
(oC)
Life Curve
100
AC Resistive
60
20
Ambient Temperature
Standard type
2.2
10
Nominal Voltage Multiplying Factor (%)
(maximum applied voltage, operating voltage characteristics)
Maximum Switching Power 2
0.2
g in ry ar tc A ac 1 nt nt: Co rre cu
Coil Temperature Rise (oC)
40
Ambient Temperature
Coil Power (W)
70
0.5 DC Resistive
30
30 20
VD C
Re
sis t
ive
Re
10
tiv
sis
0.2
40
DC
0.3
50
5V
Operation (x104)
1
12
Contact Current (A)
60
20
Coil Power (W)
Coil Temperature Rise
0
FTR-B4GB4.5Z n=100 Operate Release
Reset time
Release
0
Distribution (%)
5
Distribution of Operate and Release Voltage
Set, reset time characteristics
Nominal Voltage Multiplying Factor
n
e
0.1
1
2
5
10
20 30 50
Contact Voltage (V)
100 200
0
0.2
0.4
0.6
0.8
1.0
1.2
Contact Current (A)
FTR-B4 Series reference data 100
60
40
100
FTR-B4GB4.5Z n=100 Operate Release
80
60
40
0
10
20
30
40
50
60
70
60
40
20
0
80
Nominal Voltage Multiplying Factor (%)
10
80
60
40
20
0
1
2
3
4
5
Time (ms)
30
40
50
60
70
80
0
1
Ambient Temperature 2.4
Standard type
2.2
Contact carrying current: 0
2.0
Co cu nta rre ct nt: ca 1A rryi ng
1.8 1.6 1.4 1.2
age
olt ting v Opera il) o (hot c
1.0
ge
lta ting vo Opera oil) (cool c
0.8 0.6 0
20
40
60
80
2
3
4
Time (ms)
5
Mechanical Life Test
(maximum applied voltage, operating voltage characteristics)
Nominal Voltage Multiplying Factor (%)
FTR-B4GA4.5Z N=100 Operate Release
20
Nominal Voltage Multiplying Factor (%)
Distribution of Bounce Time 100
FTR-B4GA4.5Z n=100 Operate Release
80
20
20
Distribution (%)
Distribution of Operate and Release Time
Contact Resistance (mΩ)
Distribution (%)
100
FTR-B4GA4.5Z n=100 Operate Release
80
Distribution of Operate and Release Voltage
Distribution (%)
Distribution of Operate and Release Voltage
Distribution (%)
n
100 80
Operating Voltage
60 40
Release Voltage
20 0 500
FBR-B4GA4.5Z n=8 1200 operations/min.
100 50
Make Break
10 5 100 Initial
100
Ambient Temperature (oC)
500 1000
2000 3000 5000
Operation (x104)
1
0.5 DC Resistive 0.3 0.2
1
2
5
10
20 30 50
100 200
0
Operating Voltage
-10 -20 20
When coil is ON When coil is OFF
10 0 Release Voltage
-10 -20
20
2
4
6
Initial
8
10
Distance between relays I (mm)
0
Operating Voltage
0
-20
10
4
Release Voltage
100
50
0
2
4
6
8
10
Distance betweenCharacteristics relays I (mm) High Frequency 1.8
FTR-B4GA4.5Z n=2
When coil is ON When coil is OFF
10
-10
Operation (x10 ) High Frequency Characteristics 150
Standard type
FTR-B4GA4.5Z n=4
10
-20 20
Make Break
10 5
Magnetic Interference
20
-10
FTR-B4GA4.5Z n=8 30 operations/min. 30 VAC 1A (resistive load)
100 50
FTR-B4GA4.5Z n=2
1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2
0
0
Release Voltage
Standard type
FTR-B4GA4.5Z n=4
10
40
0 500
Isolation (dB)
Nominal Voltage Nominal Voltage Multiplying Factor (%) Multiplying Factor (%)
Magnetic Interference
Operating Voltage
60
1
Contact Voltage (V)
20
80
Insertion Loss (dB)
0.1
Electrical Life Test
100
Nominal Voltage Nominal Voltage Multiplying Factor (%) Multiplying Factor (%)
AC Resistive
Contact Resistance (mΩ)
Contact Current (A)
Nominal Voltage Multiplying Factor (%)
Maximum Switching Power 2
0 1
3 5 7 10
30 50 70 100
Frequency (MHz)
300 500 700 1000
1
3 5 7 10
30 50 70 100
Frequency (MHz)
300 500700 1000
FTR-B4 Series n DIMENSIONS AND SCHEMATICS Through hole type
5.7±0.3
5.7±0.3
Surface mount type (standard)
10.6±0.3
3.2±0.2 2.2±0.2 2.2±0.2
3.2
8-O 0.85
(-) 8
7
6
5
1 (+)
2
3
4
1.2
7.6 2.2 (-) 8
7
6
5
2
3
4
3.1
3.2
2.2
7.4±0.3
2.2±0.2 2.2±0.2
3.2±0.2
3.2±0.3
5.3
7.6 3.2
0.4±0.1 3.2±0.2
1.5±0.2
0.2±0.05
0.2±0.05
0.4±0.1
3.1
1.5±0.2
9.7±0.3
9±0.3 0.5
9±0.3 3.54±0.3
0.5±0.1
10.6±0.3
Recommended mounting pad (Tolerance: ±0.1mm)
Terminal designations (Top view de-energized position)
0.8
Recommended mounting pad (Tolerance: ±0.1mm)
1 (+)
Terminal designations (Top view de-energized position)
FTR-B4 Series
5.7±0.3
n DIMENSIONS AND SCHEMATICS Reduced mounting area
0.2±0.05
1.2
0.5
9.7±0.3
9±0.3
10.6±0.3
0.4±0.1 3.2±0.2
1.5±0.2
5.7±0.3
2.2±0.2 2.2±0.2
3.2
3.2±0.3
7.6 2.2 7
6
5
2
3
4
2.25
4.45
2.25
(-) 8
1 (+)
0.8
Recommended mounting pad (Tolerance: ±0.1mm)
Terminal designations (Top view de-energized position)
n RECOMMENDED SOLDERING CONDITIONS (TEMPERATURE PROFILE)
Temperature (C)
IRS (Infrared Reflow Soldering)
soldering
T3
T 3 = 245C max. T 2 = 200C max. cooling T 1 = 165C max.
T2 T1
0
preheating
120 sec maximum
Note:
1.Temperature profiles show the tempera ture of PC board surface. 2. Please perform soldering test with your actual PC board before mass produc tion, since the temperatures of PC board surfaces vary according to the size of PC board, status of parts mount ing and heating method.
30 sec Max.
n PRECAUTIONS
- For details on general precautions, refer to the section on technical descriptions. - Since this is a polar relay, follow the instructions of the internal wiring diagram for the +- connections of the coil. - Note that the terminal array and internal wiring of the surface mount relay are a top view.
FTR-B4 Series RoHS Compliance and Lead Free Relay Information 1. General Information Relays produced after the specific date code that is indicated on each data sheet are lead-free now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info. (http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf) l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu. From February 2005 forward Sn-3.0CU-Ni will be used for the FTR-B3 and FTR-B4 series relays. l All signal and most power relays also comply with RoHS. Please refer to individual data sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE). l It has been verified that using lead-free relays in leaded assembly process will not cause any problems (compatible). l “LF” is marked on each outer and inner carton. (No marking on individual relays). l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists. Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC) l
2. Recommended Lead Free Solder Profile l
Recommended solder paste Sn-3.0Ag-0.5Cu amd Sm-3.0 Cu-Ni (only FTR-B3 and FTR-B4 from February 2005.
Reflow Solder condtion Peak Temp.: max. 250 C Soldering
Temperature ( C)
250
Flow Solder condtion: Pre-heating: Soldering:
maximum 120˚C dip within 5 sec. at 260˚C soler bath
Solder by Soldering Iron:
220 Cooling
Pre-heating
170
Soldering Iron Temperature: maximum 360˚C Duration: maximum 3 sec.
130 90~120 sec. max. 120 sec.
20~30 sec. (duration)
We highly recommend that you confirm your actual solder conditions
3. Moisture Sensitivity Moisture Sensitivity Level standard is not applicable to electromechanical realys.
l
4. Tin Whisker SnAgCu and SnCuNi solder is known as low risk of tin whisker. No considerable length whisker was found by our in-house test.
l
FTR-B4 Series Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email:
[email protected] Web: www.fcl.fujitsu.com
Europe Fujitsu Components Europe B.V. Diamantlaan 25 2132 WV Hoofddorp Netherlands Tel: (31-23) 5560910 Fax: (31-23) 5560950 Email:
[email protected] Web: emea.fujitsu.com/components/
North and South America Fujitsu Components America, Inc. 250 E. Caribbean Drive Sunnyvale, CA 94089 U.S.A. Tel: (1-408) 745-4900 Fax: (1-408) 745-4970 Email:
[email protected] Web: http://us.fujitsu.com/relays/
Asia Pacific Fujitsu Components Asia Ltd. 102E Pasir Panjang Road #01-01 Citilink Warehouse Complex Singapore 118529 Tel: (65) 6375-8560 Fax: (65) 6273-3021 Email:
[email protected] Web: http://www.fujitsu.com/sg/services/micro/components/
©2007 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice. Rev. February 19, 2007