Preview only show first 10 pages with watermark. For full document please download

Ftr-b4-ser

   EMBED


Share

Transcript

ULTRA MINIATURE RELAY SLIM SIGNAL RELAY FTR-B4 Series RoHS compliant n Features Ultra miniature slim type relay for surface mounting Height: 9.3 mm maximum (THT) 10 mm maximum (SMT) Weight: Approximately 1.0 g l UL/CSA recognized l Conforms to Bellcore & FCC part 68, and Telcordia & FCC part 68 l Conforms to UL1950 / CSA 950, IEC 950 / EN60950 spacing and high breakdown voltage Clearance: 1.0mm Creepage: 1.6mm Basic insulation, 150V working voltage, pollution degree 2 l HIGH RELIABILITY Bifurcated contacts l Low power consumption 140 mV (standard), 100 mW (latching) l RoHS compliant since date code: 0430B8 Please see page 8 for more information l n ORDERING INFORMATION [Example] FTR-B4 C A 4.5 Z - B 05 (a) (b) (c) (d) (e) (f ) (g) (a) Series Name FTR-B4 Series (b) Terminal type C: Through hole type G: surface mount type S: surface mount type - reduced mounting area (c) Operation function A: standard type B: latching type (d) Coil Number Nominal voltage (e) Contact material Z: gold plated silver alloy (f ) Relay enclosing direction* B: standard enclosing direction (g) Number of relays per reel* 05: 500 (standard) Remarks: Actual marking on relay would not carry code FTR and be as below: Ordering code Actual marking Notes: * FTR-B4CA4.5Z → B4CA4.5Z - Only surface mount types (G and S) are applicable - All relays are packaged in tubes unles P/N ends with -B05 FTR-B4 Series n COIL DATA CHART Standard type MODEL Rated coil Coil resistance voltage (±10%) Operating voltage Release voltage* Rated power consumption FTR-B4( )A1.5Z 1.5VD C 16. 1 Ω +1.13V +0.15V 140mW FTR-B4( )A003Z 3VD C 64. 3 Ω +2.25V +0.3V 140mW FTR-B4( )A4.5Z 4.5VD C 14 5 Ω +3.38V +0.45V 140mW FTR-B4( )A006Z 6 VD C 25 7 Ω +4.5V +0.6V 140mW FTR-B4( )A009Z 9 VD C 57 9 Ω +6.75V +0.9V 140mW FTR-B4( )A012Z 12VD C 1,02 8 Ω +9.0V +1.2V 140mW FTR-B4( )A024Z 24VD C 2,50 4 Ω +18.0V +2.4V 230mW Set voltage Release voltage Rated power consumption 22. 5 Ω +1.13V -1.13V 100mW 90 Ω +2.25V -2.25V 100mW * Pulse driven Note: All values in the table are measured at 20˚C. Latching type (1 coil) MODEL Rated coil Coil resistance voltage (±10%) FTR-B4 ( )B1.5Z 1.5VD C FTR-B4 ( )B003Z 3VD C FTR-B4 ( )B4.5Z 4.5VD C 20 3 Ω +3.38V -3.38V 100mW FTR-B4 ( )B006Z 6 VD C 36 0 Ω +4.5V -4.5V 100mW FTR-B4 ( )B009Z 9 VD C 81 0 Ω +6.75V -6.75V 100mW FTR-B4 ( )B012Z 12VD C 1,44 0 Ω +9.0V -9.0V 100mW FTR-B4 ( )B024Z 24VD C 4,80 0 Ω +18.0V -18.0V 120mW * Pulse driven Note: All values in the table are measured at 20˚C.  FTR-B4 Series n SPECIFICATIONS Contact Coil Time value Insulation Standard Type Latching Type FTR-B4-CA ( ) Z FTR-B4-GA ( ) Z FTR-B4-SA ( ) Z FTR-B4-CB ( ) Z FTR-B4-GB ( ) Z FTR-B4-SB ( ) Z Arrangement 2Form C Contact material Gold overlay silver alloy Contact type Bifurcated contact (cross-bar) Contact resistance (initial value) 100mΩ maximum at 6VDC 1 Contact rating 30 VDC 1A, 125 VAC 0.3 A (resistive) Maximum carrying current 1A Maximum switching power 62.5 VA / 30W Maximum switching voltage 250 VAC. 220 VDC Maximum switching current 1A Maximum switching load* 10m VDC, 0.01mA* Capacitance Approximately 0.7 pF (between open contacts) Approximately 0.7 pF (adjacent contacts) Approximately 1.0 pF (between coil and contacts) Nominal power (at 20°C) 140 mW up to 230 mW 100 mW up to 130 mW Operate power (at 20°C) 80 mW up to 130 mW 57 mW up to 68 mW Operating temperature (no frost) -40°C to +85°C Operate (at nominal voltage, without bounce) 3ms maximum 3ms maximum (set) Release (at nominal voltage, without bounce) 3ms maximum 3ms maximum (reset) Resistance Dielectric strength Surge strength Minimum 1,000MΩ between open contacts 1,000 VAC 1 minute between adjacent contacts 1,000 VAC 1 minute between coil and contacts 1,500 VAC 1 minute between open contacts 1,500 V (at 10 x 160µs) [FCC Part 68] between adjacent contacts 1,500 V (at 10 x 160µs) [FCC Part 68] between coil and contacts 1,500 V (at 10 x 160µs) [FCC Part 68] 2,500 V (at 2 x 10µs) [Bellcore] Mechanical 50 x 106 operations (at 3 Hz) Electrical (resistive load) 100 x 103 ops. min. at 1A, 30 VDC (at 0.5 Hz) 100 x 103 ops. min. at 0.3A, 30 VDC (at 0.5 Hz) Vibration resistance Misoperation 10 to 55 Hz at double amplitude of 3 mm Endurance 10 to 55 Hz at double amplitude of 5 mm Shock resistance Misoperation Min. 750 m/s2 Endurance Min. 1,000 m/s2 Life Weight Approximately 1.0 g *1 Minimum switching loads mentioned above are reference values. Please perform the confirmation test with the actual load before production since reference values may vary according to switching frequencies, envir onmental conditions and expected reliability levels.  FTR-B4 Series characteristic data Operation (return time characteristics) Time (ms) Time (ms) 4 3 2 5 100 4 80 3 2 Operation time Set time 1 1 0 0.1 0.2 0 0.3 0.1 Coil Power (W) 60 40 Contact carrying current: 1A 20 Contact carrying current: 0 0.2 0.3 Nominal Voltage Multiplying Factor (%) 80 0.1 0.3 0 2.4 Contact carrying current: 0 2.0 Co cu nta rre ct nt: ca 1A rryi ng 1.8 1.6 1.4 1.2 ltage ng vo ti Opera il) o (hot c 1.0 ltage ting vo Opera il) o c l o (co 0.8 0.6 0 20 40 80 100 Ambient Temperature (oC) 30 40 50 60 70 80 (maximum applied voltage, operating voltage characteristics) Latching Type 2.4 2.2 Co cu nta rre ct nt ca : 1 rry A ing 2.0 1.8 1.6 1.4 1.2 age olt ting V Opera ) oil (hot c 1.0 g Voltage Operatin il) co l oo (c 0.8 0.6 0 20 40 60 80 Ambient Temperature 100 (oC) Life Curve 100 AC Resistive 60 20 Ambient Temperature Standard type 2.2 10 Nominal Voltage Multiplying Factor (%) (maximum applied voltage, operating voltage characteristics) Maximum Switching Power 2 0.2 g in ry ar tc A ac 1 nt nt: Co rre cu Coil Temperature Rise (oC) 40 Ambient Temperature Coil Power (W) 70 0.5 DC Resistive 30 30 20 VD C Re sis t ive Re 10 tiv sis 0.2 40 DC 0.3 50 5V Operation (x104) 1 12 Contact Current (A) 60 20 Coil Power (W) Coil Temperature Rise 0 FTR-B4GB4.5Z n=100 Operate Release Reset time Release 0 Distribution (%) 5 Distribution of Operate and Release Voltage Set, reset time characteristics Nominal Voltage Multiplying Factor n e 0.1 1 2 5 10 20 30 50 Contact Voltage (V) 100 200 0 0.2 0.4 0.6 0.8 1.0 1.2 Contact Current (A)  FTR-B4 Series reference data 100 60 40 100 FTR-B4GB4.5Z n=100 Operate Release 80 60 40 0 10 20 30 40 50 60 70 60 40 20 0 80 Nominal Voltage Multiplying Factor (%) 10 80 60 40 20 0 1 2 3 4 5 Time (ms) 30 40 50 60 70 80 0 1 Ambient Temperature 2.4 Standard type 2.2 Contact carrying current: 0 2.0 Co cu nta rre ct nt: ca 1A rryi ng 1.8 1.6 1.4 1.2 age olt ting v Opera il) o (hot c 1.0 ge lta ting vo Opera oil) (cool c 0.8 0.6 0 20 40 60 80 2 3 4 Time (ms) 5 Mechanical Life Test (maximum applied voltage, operating voltage characteristics) Nominal Voltage Multiplying Factor (%) FTR-B4GA4.5Z N=100 Operate Release 20 Nominal Voltage Multiplying Factor (%) Distribution of Bounce Time 100 FTR-B4GA4.5Z n=100 Operate Release 80 20 20 Distribution (%) Distribution of Operate and Release Time Contact Resistance (mΩ) Distribution (%) 100 FTR-B4GA4.5Z n=100 Operate Release 80 Distribution of Operate and Release Voltage Distribution (%) Distribution of Operate and Release Voltage Distribution (%) n 100 80 Operating Voltage 60 40 Release Voltage 20 0 500 FBR-B4GA4.5Z n=8 1200 operations/min. 100 50 Make Break 10 5 100 Initial 100 Ambient Temperature (oC) 500 1000 2000 3000 5000 Operation (x104) 1 0.5 DC Resistive 0.3 0.2 1 2 5 10 20 30 50 100 200 0 Operating Voltage -10 -20 20 When coil is ON When coil is OFF 10 0 Release Voltage -10 -20 20 2 4 6 Initial 8 10 Distance between relays I (mm) 0 Operating Voltage 0 -20 10 4 Release Voltage 100 50 0 2 4 6 8 10 Distance betweenCharacteristics relays I (mm) High Frequency 1.8 FTR-B4GA4.5Z n=2 When coil is ON When coil is OFF 10 -10 Operation (x10 ) High Frequency Characteristics 150 Standard type FTR-B4GA4.5Z n=4 10 -20 20 Make Break 10 5 Magnetic Interference 20 -10 FTR-B4GA4.5Z n=8 30 operations/min. 30 VAC 1A (resistive load) 100 50 FTR-B4GA4.5Z n=2 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 Release Voltage Standard type FTR-B4GA4.5Z n=4 10 40 0 500 Isolation (dB) Nominal Voltage Nominal Voltage Multiplying Factor (%) Multiplying Factor (%) Magnetic Interference Operating Voltage 60 1 Contact Voltage (V) 20 80 Insertion Loss (dB) 0.1 Electrical Life Test 100 Nominal Voltage Nominal Voltage Multiplying Factor (%) Multiplying Factor (%) AC Resistive Contact Resistance (mΩ) Contact Current (A) Nominal Voltage Multiplying Factor (%) Maximum Switching Power 2 0 1 3 5 7 10 30 50 70 100 Frequency (MHz) 300 500 700 1000 1 3 5 7 10 30 50 70 100 Frequency (MHz) 300 500700 1000  FTR-B4 Series n DIMENSIONS AND SCHEMATICS Through hole type 5.7±0.3 5.7±0.3 Surface mount type (standard) 10.6±0.3 3.2±0.2 2.2±0.2 2.2±0.2 3.2 8-O 0.85 (-) 8 7 6 5 1 (+) 2 3 4 1.2 7.6 2.2 (-) 8 7 6 5 2 3 4 3.1 3.2 2.2 7.4±0.3 2.2±0.2 2.2±0.2 3.2±0.2 3.2±0.3 5.3 7.6 3.2 0.4±0.1 3.2±0.2 1.5±0.2 0.2±0.05 0.2±0.05 0.4±0.1 3.1 1.5±0.2 9.7±0.3 9±0.3 0.5 9±0.3 3.54±0.3 0.5±0.1 10.6±0.3 Recommended mounting pad (Tolerance: ±0.1mm) Terminal designations (Top view de-energized position) 0.8 Recommended mounting pad (Tolerance: ±0.1mm) 1 (+) Terminal designations (Top view de-energized position)  FTR-B4 Series 5.7±0.3 n DIMENSIONS AND SCHEMATICS Reduced mounting area 0.2±0.05 1.2 0.5 9.7±0.3 9±0.3 10.6±0.3 0.4±0.1 3.2±0.2 1.5±0.2 5.7±0.3 2.2±0.2 2.2±0.2 3.2 3.2±0.3 7.6 2.2 7 6 5 2 3 4 2.25 4.45 2.25 (-) 8 1 (+) 0.8 Recommended mounting pad (Tolerance: ±0.1mm) Terminal designations (Top view de-energized position) n RECOMMENDED SOLDERING CONDITIONS (TEMPERATURE PROFILE) Temperature (C) IRS (Infrared Reflow Soldering) soldering T3 T 3 = 245C max. T 2 = 200C max. cooling T 1 = 165C max. T2 T1 0 preheating 120 sec maximum Note: 1.Temperature profiles show the tempera ture of PC board surface. 2. Please perform soldering test with your actual PC board before mass produc tion, since the temperatures of PC board surfaces vary according to the size of PC board, status of parts mount ing and heating method. 30 sec Max. n PRECAUTIONS - For details on general precautions, refer to the section on technical descriptions. - Since this is a polar relay, follow the instructions of the internal wiring diagram for the +- connections of the coil. - Note that the terminal array and internal wiring of the surface mount relay are a top view.  FTR-B4 Series RoHS Compliance and Lead Free Relay Information 1. General Information Relays produced after the specific date code that is indicated on each data sheet are lead-free now. Most of our signal and power relays are lead-free. Please refer to Lead-Free Status Info. (http://www.fujitsu.com/us/downloads/MICRO/fcai/relays/lead-free-letter.pdf) l Lead free solder paste currently used in relays is Sn-3.0Ag-0.5Cu. From February 2005 forward Sn-3.0CU-Ni will be used for the FTR-B3 and FTR-B4 series relays. l All signal and most power relays also comply with RoHS. Please refer to individual data sheets. Relays that are RoHS compliant do not contain the 5 hazardous materials that are restricted by RoHS directive (lead, mercury, chromium IV, PBB, PBDE). l It has been verified that using lead-free relays in leaded assembly process will not cause any problems (compatible). l “LF” is marked on each outer and inner carton. (No marking on individual relays). l To avoid leaded relays (for lead-free sample, etc.) please consult with area sales office. l We will ship leaded relays as long as the leaded relay inventory exists. Note: Cadmium was exempted from RoHS on October 21, 2005. (Amendment to Directive 2002/95/EC) l 2. Recommended Lead Free Solder Profile l Recommended solder paste Sn-3.0Ag-0.5Cu amd Sm-3.0 Cu-Ni (only FTR-B3 and FTR-B4 from February 2005. Reflow Solder condtion Peak Temp.: max. 250 C Soldering Temperature ( C) 250 Flow Solder condtion: Pre-heating: Soldering: maximum 120˚C dip within 5 sec. at 260˚C soler bath Solder by Soldering Iron: 220 Cooling Pre-heating 170 Soldering Iron Temperature: maximum 360˚C Duration: maximum 3 sec. 130 90~120 sec. max. 120 sec. 20~30 sec. (duration) We highly recommend that you confirm your actual solder conditions 3. Moisture Sensitivity Moisture Sensitivity Level standard is not applicable to electromechanical realys. l 4. Tin Whisker SnAgCu and SnCuNi solder is known as low risk of tin whisker. No considerable length whisker was found by our in-house test. l  FTR-B4 Series Fujitsu Components International Headquarter Offices Japan Fujitsu Component Limited Gotanda-Chuo Building 3-5, Higashigotanda 2-chome, Shinagawa-ku Tokyo 141, Japan Tel: (81-3) 5449-7010 Fax: (81-3) 5449-2626 Email: [email protected] Web: www.fcl.fujitsu.com Europe Fujitsu Components Europe B.V. Diamantlaan 25 2132 WV Hoofddorp Netherlands Tel: (31-23) 5560910 Fax: (31-23) 5560950 Email: [email protected] Web: emea.fujitsu.com/components/ North and South America Fujitsu Components America, Inc. 250 E. Caribbean Drive Sunnyvale, CA 94089 U.S.A. Tel: (1-408) 745-4900 Fax: (1-408) 745-4970 Email: [email protected] Web: http://us.fujitsu.com/relays/ Asia Pacific Fujitsu Components Asia Ltd. 102E Pasir Panjang Road #01-01 Citilink Warehouse Complex Singapore 118529 Tel: (65) 6375-8560 Fax: (65) 6273-3021 Email: [email protected] Web: http://www.fujitsu.com/sg/services/micro/components/ ©2007 Fujitsu Components America, Inc. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. Fujitsu Components America or its affiliates do not warrant that the content of datasheet is error free. In a continuing effort to improve our products Fujitsu Components America, Inc. or its affiliates reserve the right to change specifications/datasheets without prior notice. Rev. February 19, 2007