Cable Entry Left Side
FTTX Solutions Fixed Flexible Fiber Box
Cable Entry Right Side
Quick Reference Guide RETAINING NUT
RETAINING NUT
O-RING METAL SPACER GROMMET
NOTE:
COMPRESSION FITTING BASE
O-RING COMPRESSION FITTING BASE
COMPRESSION NUT
COMPRESSION NUT
All cables enter from the bottom Multiple cables may enter through the same port Two entry ports are provided on left side Accepts 2 to 5 mm cables depending on the configuration. See User Manual for details
NOTE:
METAL SPACER GROMMET
TECP-90-615 · Issue 3 · November 2016 The Fixed Flexible Fiber Box ( Fixed FFB) allows mixing and matching of feeder and drop cable interface options in a compact metal cabinet. Either side of the Fixed FFB may be configured as the feeder interface or the drop interface. The feeder and drop interface options include MPO adapters, HMFOC adapters, fixed bulkhead adapters (LC or SC), splice trays, and sliding adapter packs (LC or SC). Both a 12-fiber and a 24-fiber configuration is available. The following drawings show some typical Fixed FFB configurations.
All cables enter from the bottom Multiple cables may enter through the same port Two entry ports are provided on right side Accepts 2 to 5 mm cables depending on the configuration. See User Manual for details.
DROP SIDE
FEEDER SIDE
SLIDING ADAPTER PACKS
INTERNAL MPO ADAPTERS
FEEDER INTERFACE SIDE
FEEDER SIDE
DROP INTERFACE SIDE
DROP SIDE FIXED BULKHEAD ADAPTERS
SPLICE TRAY
CABINET DIMENSIONS WIDTH: 12.75 INCHES HEIGHT: 11.5 INCHES DEPTH: 6.8 INCHES (with bracket)
PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: Phone: 800.830.5056 Email:
[email protected] Website: www.commscope.com. This product is covered by one or more U.S.patents or their foreign equivalents. For patents, see www.commscope.com/ProductPatent/ProductPatent.aspx
FEEDER SIDE
DROP SIDE
EXTERNAL HMFOC ADAPTERS
FIXED BULKHEAD ADAPTERS
CABLE ENTRY FITTINGS DROP SIDE
FEEDER SIDE
SLIDING ADAPTER PACKS
FIXED BULKHEAD ADAPTERS
CommScope (logo) and CommScope are trademarks. Contents herein are current as of the date of publication. CommScope reserves the right to change the contents without prior notice. In no event shall CommScope be liable for any damages resulting from loss of data, loss of use, or loss of profits and CommScope further disclaims any and all liability for indirect, incidental, special, consequencial or other similar damages. This disclaimer of liability applies to all products, publications, and services during and after the warranty period. 24666-C
© 2016 CommScope. All Rights Reserved.
300001735704 Rev C
© 2016 CommScope. All Rights Reserved.
1
Tools and Materials
3
General
Pole Mount
Pliers
Drill
#2 Phillips Screwdriver
9/32-inch Drill Bit
Tape Measure
9/16-Inch Wrench
Pen or Marker
Optional
3/32-Inch Drill Bit
1/2-Inch Threaded Rod (1) or
Screwdriver Drill Bit
1/2-Inch Through-Bolt (1)
Masonry Wall
Torque Wrench With 7/16-Inch Socket 2-Hole Compression Lug
1/2-Inch Nut (2)
Crimping Tool
1/2-Inch Flat Washer (2)
External Grounding System
1/2-Inch Lock Washer (2)
LC or SC Connector Cleaning Kit MPO Connector Cleaning Kit (MPO FFB)
3/4-Inch Wrench
#10 x 1-1/2-Inch Wood Screw (4) #10 Flat Washer (4) Drill
#6 COPPER GROUNDING WIRE
3/8-Inch Concrete Anchor 3/8-Inch x 1-1/2-Inch hex head capscrew (2) 3/8-Inch Flat Washer (2) 3/8-Inch Lock Washer (2)
NOTE:
5/8-Inch Masonry Drill Bit (check with supplier)
Pad Lock (optional)
Connect free end of grounding wire to an approved earth ground source as specified by local code or practice.
9/16-Inch Wrench Installation and assembly can be completed by one person.
2A Pole Mount Option
TO OPEN CABINET DOOR OR NTERNAL COVER, BACK OUT CAP SCREW (REQUIRES 216B KEY TOOL)
TIGHTEN TO 40 TO 45 LBS FORCE-INCHES (4.5 TO 5.1 Nm) OF TORQUE
Drill
Splicing Equipment (splicing FFB)
NOTE:
Opening and Closing Cabinet
TWO-HOLE LUG WITH 0.625 INCH HOLE SPACING
Wood-Framed Wall
3/8-inch x 2-Inch Lag Screw (2))
Wire Cutter
1/4-INCH DIAMETER GROUNDING STUDS
Wall Mount
216B Key Tool (accessory)
4
Grounding
!
Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.
2B
Wall Mount Option
TO CLOSE DOOR, LIFT WIND JAMMER
!
OPTIONAL INTERNAL COVER
Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm.
WELDED BRACKET
WELDED BRACKET
33//44-I -IN NC CH B BA CK H PPLLYYW ((SSECAC KEER WO OO OD ECU D UR BO REETTOR B OA AR D OW WA ALLLL S RD
WOODEN UTILITY POLE
STTU UD DSS))
MOUNTING BRACKET
MOUNTING BRACKET MOUNTING BRACKET
MOUNTING BRACKET
24219-A
FASTENERS USED TO SECURE BRACKET TO WOODEN UTILITY POLE
CAP SCREW WITH CUP WASHER
Use appropriate climbing and lifting equipment when mounting the FFB on a pole. NOTE: 3/8-INCH X 2-INCH LAG SCREW (2)
FASTENERS USED TO SECURE BRACKET TO BACKER BOARD
#10 FLAT WASHER (4)
Install a grounding system that meets all local electrical codes. If the utility pole is not in good condition, it is recommended that in addtition to the lag screws, a 1/2-inch threaded rod or through-bolt be used to secure the mounting bracket to the pole. Refer to the User Manual for additional information.
CAP SCREW WITH CUP WASHER
#10 X 1-1/2 INCH WOOD SCREW (4)
Fasten the 3/4-inch plywood backer board securely to the wall studs. NOTE:
Install a grounding system that meets all local electrical codes. If securing mounting bracket to a masonry surface, use the recommended masonry fasteners. Refer to the User Manual for additional information.
24675-C