Preview only show first 10 pages with watermark. For full document please download

сервизно ръководство Fujitsu Auyg-lvlb

   EMBED


Share

Transcript

SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit AUYG12LVLB AOYG12LALL AUYG14LVLB AOYG14LALL AUYG18LVLB AOYG18LALL CO NTE NTS SPECIFICATIONS . . . . . . . . . . . . . . . . . . 1 DIMENSIONS. . . . . . . . . . . . . . . . . . . . . . 2 REFRIGERANT SYSTEM DIAGRAM . . . 4 CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . 5 INDOOR PCB CIRCUIT DIAGRAM . . . . . 6 OUTDOOR PCB CIRCUIT DIAGRAM. . .10 ERROR DETECTION . . . . . . . . . . . . . . .12 PARTS (DECORATION PANEL) . . . . . . 14 PARTS (INDOOR UNIT). . . . . . . . . . . . .16 PARTS (OUTDOOR UNIT) . . . . . . . . . . .19 ACCESSORIES . . . . . . . . . . . . . . . . . . . 21 S PE CI FI CAT IO NS NOISE LEVEL ELECTRICAL DATA TYPE Inverter cooling & heating UTG-UFYD-W DECORATION PANEL High 37 dB 38 dB 38 dB Medium 34 dB 34 dB 34 dB 30 dB 30 dB 30 dB INDOOR UNIT (cool) Low INDOOR UNIT AUYG12LVLB AUYG14LVLB AUYG18LVLB OUTDOOR UNIT AOYG12LALL AOYG14LALL AOYG18LALL Quiet 27 dB 27 dB 26 dB High 37 dB 43 dB 43 dB Medium 34 dB 38 dB 38 dB 31 dB 34 dB 34 dB 29 dB 30 dB 30 dB COOLING CAPACITY 3.50 kW 4.30 kW 5.20 kW HEATING CAPACITY 4.10 kW 5.00 kW 6.00 kW INDOOR UNIT (heat) Low 230 V, 50 Hz POWER SOURCE Quiet RUNNING CURRENT Cooling 4.8 A 6.1 A 7.2 A Heating 5.1 A 6.1 A 7.4 A OUTDOOR UNIT (cool) 47 dB 49 dB 50 dB INPUT WATTS Cooling 1.05 kW 1.33 kW 1.62 kW OUTDOOR UNIT (heat) 48 dB 49 dB 50 dB Heating 1.11 kW 1.34 kW 1.66 kW E.E.R. Cooling 3.33 kW/kW 3.21 kW/kW 3.21 kW/kW COP Heating 3.69 kW/kW 3.71 kW/kW 3.61 kW/kW MOISTURE REMOVAL AIR CIRCULATION (HIGH) MAXIMUM CURRENT 1.2 L/hr 1.5 L/hr 2.2 L/hr Cooling 600 m3/hr 680 m3/hr 680 m3/hr Heating 600 m3/hr 800 m3/hr 680 m3/hr Cooling 7.5 A 9.0 A 9.0 A Heating 10.0 A 12.5 A 12.5 A WEIGHT (with oil) 9.6 kg REFRIGERANT TYPE R410A 1,150 g 1,250 g 1,250 g 1,150 g 1,250 g 1,250 g 20 m 1,250 g 1,350 g 1,350 g 25 m 1,350 g 1,450 g 1,450 g PRECHARGED FULL CHARGE MFF-24RVL ADDITIONAL CHARGE 20 g/m MAXIMUM PIPING HEIGHT 15 m High 650 r.p.m. 730 r.p.m. 730 r.p.m. Medium 580 r.p.m. 630 r.p.m. 630 r.p.m. 520 r.p.m. 540 r.p.m. 540 r.p.m. Quiet 460 r.p.m. 460 r.p.m. 460 r.p.m. High 650 r.p.m. 830 r.p.m. 830 r.p.m. 580 r.p.m. 730 r.p.m. 730 r.p.m. Low 520 r.p.m. 630 r.p.m. 630 r.p.m. PANEL Net / Shipping 2.6 kg / 4.5 kg Quiet 460 r.p.m. 500 r.p.m. 500 r.p.m. INDOOR UNIT Net / Shipping 15 kg / 18 kg OUTDOOR UNIT Net / Shipping 40 kg / 44 kg INDOOR UNIT (cool) Low INDOOR UNIT Medium (heat) DIMENSIONS PANEL MFE-63NOM OUTDOOR UNIT, Discrimination OUTDOOR UNIT (cool) 770 r.p.m. 820 r.p.m. 860 r.p.m. OUTDOOR UNIT (heat) 700 r.p.m. 750 r.p.m. 820 r.p.m. 2011.12.12 DA130A1F-25NA COMPRESSOR Pipe length 15 m FAN MOTOR INDOOR UNIT, Discrimination COMPRESSOR AND REFRIGERANT 1 HxWxD 49 x 700 x 700 mm INDOOR UNIT H x W x D 245 x 570 x 570 mm OUTDOOR UNIT H x W x D 578 x 790 x 300 mm WEIGHT D IMENS IONS Unit : mm Decoration panel mounting state Be sure to leave maintenance space for future service at the designated position. Maintenance space Min. 450 Drain port 40 99 102 Drain port 2011.12.12 2 58 Ceiling 123 30 215 262 30 30 108 146 245 114 102 700 Ceiling openings 250 Min. 450 135 150 to 200 75 540 : Hanging bolt position 530 : Hanging bolt position 49 DECORATION PANEL 30 INDOOR UNIT 700 OUTDOOR UNIT Unit : mm 66 300 10 578 790 347 320 Air flow 540 2011.12.12 3 REF RIGER AN T SYSTEM D IA G RA M OUTDOOR UNIT INDOOR UNIT Muffler Cooling Heating 3-way valve Muffler 4-way valve Heat exchanger Heat exchanger Accumulator Compressor Strainer Expansion valve Strainer 2-way valve : Compressor thermistor : Discharge pipe thermistor : Heat exchanger thermistor (Middle) : Heat exchanger thermistor (Out) : Outdoor thermistor 2011.12.18 : Pipe thermistor : Room thermistor 4 12 Liquid : 1/4" (6.35 mm) Gas : 3/8" (9.52 mm) 14, 18 Liquid : 1/4" (6.35 mm) Gas : 1/2" (12.70 mm) CI RC UI T D IA GR AM GRAY GRAY 1 2 3 4 5 RED ORANGE YELLOW PINK BLUE BLACK BLACK 1 2 3 4 5 1 2 3 4 5 1 2 CN7 1 2 3 CN12 4 CONTROLLER 5 1 2 3 CN11 4 5 PCB ASSY ( MAIN PCB ) 1 2 3 CN13 4 5 6 7 1 1 2 2 CN9 3 3 FLOAT SWITCH 1 CN10 2 1 2 3 4 5 6 7 BROWN RED ORANGE YELLOW WHITE BLUE PURPLE 1 2 3 4 5 6 7 1 2 3 4 5 6 7 CN6 1 CN1 2 1 2 3 1 2 3 EX OUT ( OPTION ) EX I N ( OPTION ) BLACK BLACK BROWN BROWN THERMISTOR ( DISCHARGE TEMP. ) 1 2 3 4 5 6 7 FRESH AIR ( OPTION ) INDICATOR PCB ASSY 1 2 3 TERMINAL W10 W11 1 2 3 4 1 1 2 2 CN73 THERMISTOR ( PIPE - M I D. TEMP. ) BLACK BLACK 1 1 2 2 CN72 THERMISTOR ( OUTDOOR TEMP. ) BLACK BLACK 1 1 2 2 3 3 RED 1 FUSE 5A 250V TERMINAL 2 3 CN71 WHITE BLACK TERMINAL 1 2 3 (N) FUSE 20A 250V L N POWER SOURCE M DRAIN PUMP MOTOR 5 CM COMPRESSOR RED CN800 1 2 3 4 5 6 7 CN40 1 2 3 4 5 6 CN30 1 1 2 2 BLACK 3 3 CN70 R(R) S(S) C(T) CONTROLLER PCB ASSY BROWN BROWN WIRED REMOTE CONTROL ( OPTION ) RED WHITE BLACK 1 2 3 4 RED WHITE BLACK W7 W8 W9 THERMISTOR ( COMP. TEMP. ) WHITE GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY 2011.11.14 GREEN 1 2 3 4 5 6 7 8 THERMISTOR ( PIPE TEMP. ) 1 2 3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 BROWN CN101 CN104 1 1 YELLOW W105 2 2 CN105 WHITE W102 3 3 BLACK POWER SUPPLY W101 4 4 PCB ASSY 5 5 RED 6 6 CN103 CN106 E101 E102 1 2 3 1 2 1 2 1 2 GREEN FM 1 2 3 4 5 6 7 8 WHITE RED 1 1 RED CN14 2 2 WHITE 3 3 BLACK CN4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 FAN MOTOR 1 2 3 CN3 4 5 6 GREEN M 1 2 3 4 5 RED ORANGE YELLOW PINK BLUE BLACK LOUVER ( UP / DOWN ) 1 2 3 4 5 REACTOR BLACK M 1 2 3 4 5 1 2 1 2 CN8 YELLOW YELLOW LOUVER ( RIGHT / LEFT ) 1 2 1 2 CN5 OUTDOOR UNIT THERMISTOR ( PIPE TEMP. ) THERMISTOR ( ROOM TEMP. ) BLACK BLACK BLACK INDOOR UNIT BLACK WHITE YELLOW BLUE 1 2 3 4 5 6 RED BROWN BLUE ORANGE YELLOW WHITE FM FAN MOTOR PMV EXPANSION VALVE W4 BLACK W2 W1 W3 4WV 4-WAY VALVE I NDO O R PCB CIRC UI T DI AGR AM CONTROL UNIT AUYG12LVLB : EZ-01113HSE AUYG14LVLB : EZ-01114HSE AUYG18LVLB : EZ-01115HSE CN8 B02B-XASK-1-A CN8-1 CN8-2 THERMISTOR ( ROOM TEMPERATURE ) BLACK BLACK WHITE CN7 B02B-XAYK-1-A CN7-1 CN7-2 YELLOW TEST CN2-1 CN2-2 CN2-3 CN2-4 CN2-5 CN5 B02B-XAKK-1-A CN2 B5P-SHF-1AA CN5-1 CN5-2 THERMISTOR (PIPE - MID. TEMPERATURE ) GRAY GRAY BLACK WHITE DECORATION PANEL ASSEMBLY 1 L POWER SOURCE AC230V 50Hz N 2 SERIAL 3 CN15-1 CN15-2 CN15-3 CN15-4 CN15-5 CN15-6 TERMINAL HP-T3031-3-L1 E WHITE WHITE CN13 B07B-PASK-1 WHITE UL1015 AWG20 UL1015 AWG20 UL1015 AWG20 RED WHITE BLACK W105 UL1015 AWG16 CN3-1 CN3-2 CN3-3 CN3-4 CN3-5 CN3-6 E102 GREEN BROWN RED ORANGE YELLOW GREEN BLUE PURPLE 1 2 3 4 5 6 7 UL1430 AWG28 x7 1 2 3 4 5 6 7 CN201-1 CN201-2 CN201-3 CN201-4 CN201-5 CN201-6 CN201-7 BROWN RED ORANGE YELLOW GREEN BLUE PURPLE UL1430 AWG28 x7 CN201 S07B-PASK-2 WHITE UL1430 AWG22 CN14-1 CN14-2 UL1430 AWG22 WHITE BLACK CN14-3 UL1430 AWG22 BLACK EMI FILTER ZCAT1518-0730 2T WHITE TERMINAL HP-T3031-21 POWER DRIVE RED BLACK WHITE YELLOW BROWN CN105-6 CN105-5 CN105-4 CN105-3 CN105-2 CN105-1 CN105 B5P6-VH-B CN104 B08B-PASK-1 WHITE WHITE GRAY GRAY GRAY GRAY GRAY GRAY GRAY GRAY CN104-1 CN104-2 CN104-3 CN104-4 CN104-5 CN104-6 CN104-7 CN104-8 CN6 B02B-PAMK-1 CN4-1 CN4-2 CN4-3 CN4-4 CN4-5 CN4-6 CN4-7 CN4-8 CN4 B08B-PASK-1 CN1-1 CN1-2 CN1-3 CN1 B03B-PASK-1 RED CN14 B03B-XAKK-1-A CN3 B06B-PASK-1 POWER SUPPLY PCB ASSEMBLY K06AL-1007HSE-P0 EMI FILTER ZCAT2132-1130 1T FM CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUYG12LVLB : K06AK-1104HSE-C1 AUYG14LVLB : K06AK-1105HSE-C1 AUYG18LVLB : K06AK-1106HSE-C1 W101 F101 AC250V 3.15A UL1015 AWG16 DC FAN MOTOR CN13-1 CN13-2 CN13-3 CN13-4 CN13-5 CN13-6 CN13-7 E101 GREEN 1 2 3 4 5 6 7 8 W102 INDICATOR PCB ASSEMBLY K06AG-1000HSE-D0 JUNCTION CONNECTOR XMR-07V CN15 B06B-XASK-1-A GREEN CN6-1 BLK WHT RED FRESH AIR ( OPTION ) CN6-2 WHITE UL1430 AWG26 x 8 UL1015 AWG22 x 5 DRAIN PUMP M UL1015 AWG18 UL1015 AWG18 YELLOW YELLOW CN106-1 CN106-2 CN106 B2P3-VH-B-E BLUE CN10 B02B-PAOK-1 DC SUPPLY CN101 B03B-PASK-1 WHITE GRAY GRAY GRAY CN101-1 CN101-2 CN101-3 ORANGE CN10-1 WIRED REMOTE CONTROL CN10-2 WHITE UL1430 AWG26 x 3 EMI FILTER ZCAT1518-0730 1T EXTERNAL OUTPUT CN103-1 CN103-2 CN11 B05B-XASK-1-A WHITE CN103 B2B-XH-AM CN11-1 CN11-2 CN11-3 CN11-4 CN11-5 RED ORANGE YELLOW PINK BLUE RED ORANGE YELLOW PINK BLUE M LOUVER ( UP / DOWN ) M LOUVER ( RIGHT / LEFT ) UL1430 AWG26 x 5 WHITE CN12 B05B-XARK-1-A RED CN12-1 CN12-2 CN12-3 CN12-4 CN12-5 RED ORANGE YELLOW PINK BLUE RED ORANGE YELLOW PINK BLUE UL1430 AWG26 x 5 CN102-1 EXTERNAL I NPUT CN102-2 CN102-3 CN102 B5P6-VH-B WHITE FLOAT SWITCH CN9 B03B-XARK-1-A RED 2011.11.14 6 CN9-1 CN9-2 CN9-3 UL1007 AWG24 BLACK UL1007 AWG24 BLACK INDOOR UNIT CONTROLLER PCB ASSEMBLY ( MAIN PCB ) AUYG12LVLB : K06AK-1104HSE-C1 AUYG14LVLB : K06AK-1105HSE-C1 AUYG18LVLB : K06AK-1106HSE-C1 5V D4 1SS355 13.5V CN1 B03B-PASK-1 1 DC SUPPLY 2 3 I R45 10k <1/10W> 12V O 3 G C1 + 10/ 50V JM1 C2 + 10/ 50V 2 C31 0.01 JM3 5V O 3 G FLOAT SWITCH 3 C32 + 100/ 6.3V R15 - R18 10k <1/10W> x 4 C8 - C10 0.1 x 3 C33 0.1 C29 0.1 R57 1.0k <1/10W> R59 10k <1/10W> C30 0.1 R58 1.0k <1/10W> R60 49.9k <1/10W> C34 0.1 R62 1.0k <1/10W> R61 49.9k <1/10W> CN7 B02B-XAYK-1-A 1 2 CN5 B02B-XAKK-1-A 1 THERMISTOR ( PIPE - M I D. TEMP. ) 2 5V C3 0.01 2 2 R46 1.0k <1/10W> THERMISTOR ( ROOM TEMP. ) 2 R4 - R6 1.0k <1/10W> x 3 5V 1 I 1 CN9 B03B-XARK-1-A ( LF ) ( SN ) 1 JM2 D1 1SS355 I C2 NJM7805 CN8 B02B-XASK-1-A R1 - R3 10k <1/10W> x 3 5V I C8 NJM7812 1 5V 5V C28 0.1 5V CN15 B06B-XASK-1-A 5V R50 10k <1/10W> 1 2 CN2 B5P-SHF-1AA 3 R19 - R22 1.0k <1/10W> x 4 FLASH 4 1 5 2 6 3 TEST 4 5 C4 0.01 C7 1000p 34 39 36 43 44 45 46 33 32 31 30 29 28 27 26 18 19 20 21 22 23 11 12 13 14 38 37 41 40 25 9 42 R24, R23, R32 5V 10k <1/10W> x 3 13.5V CN3 B06B-PASK-1 R66 10k <1/10W> R63 - R65 1.0k <1/10W> x 3 1 2 R70 10k <1/10W> 3 SP PCB 4 5 6 R67 1.0k <1/10W> 5V C37 0.1 R26 10k <1/10W> C36 0.47 Q3 DTC124EKA C35, C12, C11 1000p x 3 3 C14 1000p R25 1.0k <1/10W> R69 10k <1/10W> I C1 uPD78F0536AGK C5 1000p 1 2 AVREF AVDD VDD0 IC RST* VDD1 P00 P34 P35 P01 P02 P36 P03 P40 P41 P10 P11 P42 P43 P12 P13 P44 P14 P45 P46 P15 P16 P47 P50 P17 P51 P20 P21 P52 P22 P53 P23 P54 P55 P24 P25 P56 P30 P57 P31 P64 P32 P65 P33 P66 XT1 P67 XT2 P70 X1 P71 X2 P72 AGND P73 GND0 P74 GND1 P75 JM5 0R0 35 10 24 15 16 17 57 58 59 60 61 62 63 64 1 2 3 4 5 6 7 8 53 54 55 56 47 48 49 50 51 52 C15 0.01 5 6 R37 10k <1/10W> 1 2 FRESH AIR CN10 B02B-PAOK-1 13.5V 2011.11.14 C13 0.1 NC 7 GND 5 C24 1000p I C5 S-93C66BD0 I I C6-1 BA10393F - 6 7 5V + R55 10k <1/10W> SW1 CFS-0402MC 8 7 6 5 C17 0.01 R11 - R14 10k <1/10W> x 4 R54 15.4k <1/10W> D2 R53 12V DAN217U 28k <1/10W> 1 3 2 C18 0.01 12V CN14 B03B-XAKK-1-A ( LF ) ( SN ) D3 D1FS4A 1 2 REMOTE CONTROL UNIT R48 10k <1/10W> R35 1.0k <1/10W> 1 C19 - C22 0.1 x 4 2 3 3 R36 0R0 B. Z. 4 R7 - R10 1.0k <1/10W> x 4 7 3 R47 390 <1/10W> Q2 DTC124EKA 3 2 1 6 12V 13.5V 5V I NDICATOR PCB ASSY 5 C26 0.01 5 I C6-1 BA10393F - 2 1 + BZ1 PKM13EPYH-4000-A0 13.5V I C4 uLN2003ADR 1 2 3 4 5 6 7 I1 I2 I3 I4 I5 I6 I7 SK O1 O2 O3 O4 O5 O6 O7 GND 9 16 15 14 13 12 11 10 8 1 CN11 B05B-XASK-1-A 2 3 LOUVER ( UP / DOWN ) 4 5 CN12 B05B-XARK-1-A 1 2 I C3 13.5V uPA2003ADR 9 16 15 14 13 12 11 10 8 SK O1 O2 O3 O4 O5 O6 O7 GND I1 I2 I3 I4 I5 I6 I7 3 4 1 2 3 4 5 6 7 5 1 HEATER 3 4 VCC 8 DO 4 1 CS 2 SK 3 DI 6 NC C25 + 10/ 50V R42 47 <1/10W> 2 R33 10k <1/10W> CN6 13.5V B02B-PAMK-1 2 C23 0.01 C16 0.01 R31 10k <1/10W> CN13 B07B-PASK-1 5V 5V X1 8.00MHz 8 R34 1.0k R27 <1/10W> 330 <1/10W> R68, R52 10k <1/10W> x 2 R43, R44 10k <1/10W> R41 x2 1.0k <1/10W> 1 Q1 DTC124EKA 7 5V 5V NC 2 1 4 2 VDD NC 3 1 OUT GND 4 3 3 3 POWER DRIVE 5V I C7 S-80842CNNB C38 0.1 R40 10k <1/10W> R29 390 <1/10W> 1 2 C27 0.1 1 5V R28 10k <1/10W> CN4 B08B-PASK-1 R56 100k <1/10W> 2 7 LOUVER ( RIGHT / LEFT ) R103 62k 340V I C26-14 L R104 330k <2W> D108 D2FL20U 12 2 3 5 6 7 8 D102 1SR139-600 + 10 F101 3.15A 250V LF101 ELF17N015A FH101 FH102 W101 L101 REP28-15 15mH, 1.1A 1 1 W102 2 C104 0.47 VA101 470V WHITE C105 0.010 4 SA101 RA-362M C107 + 100/ 450V Q102 2SC1815 C110 0.047 VA102 470V 2 1 R107 100 <1/10W> D107 RD16 C112 + 330/ 25V D103 R108 D1FL20U 100 <1/2W> D104 D105 MTZJ5.1B D1FL20U 3 D109 MTZJ5.1B R110 10k <1/10W> C118 0.01 E102 GREEN R111 10k <1/10W> C114, C115 0.01 x2 1 3 R106 1.5 C113 1000/ 25V D106 D1FL20U 2 R105 75 4 C106 0.010 3 Q101 2SC5354 2 3 BLACK 15V C109 220p D101 D3SB60 13.5V T101 ZFT22B03-C C108 4700p R109 C111 100/ 330 + <1/4W> 25V A I C26-10 N E101 GREEN CN105 B5P-VH-B 340V 15V 6 5 4 DC FAN MOTOR 3 5V 1 2 A I C104 15V TLP621 R116 1.0k 4 <1/4W> HI2003R3 1 15V I C103 TLP621 3 + C117 R117 820 100/ <1/4W> A A25V CN104 B08B-PASK-1 IC105 2 18 8 4 1 3 2 R114 4.7k <1/10W> W105 R115 6.8k <1/4W> RED VA103 0.01 14 10 7 6 3 4 5 5 4 3 2 2 1 1 5V SERIAL 1 2 3 4 POWER DRIVE I C26-14 I C26-10 L N 5 6 INDOOR UNIT POWER SUPPLY PCB ASSEMBLY K06AL-1007HSE-P0 7 8 R113 330 <1/10W> 5V CN101 B03B-PASK-1 K101 G5N-1A 13.5V 1 2 3 2 3 C121 0.1 CN103 B2B-XH-AM I C26-14 1 EXTERNAL OUT L R112 330 <1/10W> I C101 TLP621 3 2 I C26-10 CN102 B3B-XH-AM N 3 2 EXTERNAL I N 1 1 L103 BLm18 K102 G5NB-1A 3 2 1 4 CN106 B2P3-VH-B-E 13.5V 2 DRAIN PUMP L102 5V BLm18 C120 0.1 4 2011.11.14 13.5V 2 1 DC SUPPLY 4 C116 0.01 8 RC101 120/ 0.1 1 INDOOR UNIT INDICATOR PCB ASSEMBLY ( OPTION ) K06AG-1000HSE-D0 5V TO CONTROLLER PCB ASSEMBLY ( MAIN PCB ) R201 220 <1/4W> CN201 S07B-PASK-2 ( LF ) ( SN ) R202 390 <1/4W> OPERATE 1 TIMER 2 FILTER CLEN / FILTER SIGN 3 5V 4 REMOTE CONTROL 5 GND 6 MANUAL AUTO SWITCH 7 R203 220 <1/4W> 2 4 D201 SLR-325MC GREEN D202 SLR-325DC ORANGE D203 SLR-325MC GREEN C202 + 10/ 25V 1 3 SW201 EVQPAG04K C201 0.1 PHA201 P I C-37143TH5 VCC 2 OUT 1 GND 3 2011.11.14 9 O UTD OO R PCB CI RCUI T DI AG RAM INVERTER ASSEMBLY AOYG12LALL : EZ-0111FHUE AOYG14LALL : EZ-0111GHUE AOYG18LALL : EZ-0111HHUE TO INDOOR UNIT F202 5A 250V W103 L N SERIAL UL1015 AWG20 1 EMI FILTER UL1015 AWG14 BLACK BLACK UL1015 AWG14 2 WHITE W100 UL1015 AWG20 3 UL1015 AWG20 WHITE RED W102 UL1015 AWG20 POWER SOURCE 230V 50Hz UL1015 AWG16 BLACK L F201 W101 N UL1015 AWG14 BLACK GREEN 20A 250V W1 B W2 B REACTOR U W7 B V W8 B W W9 B W4 B COMPRESSOR UL3271 AWG16 RED RED UL3271 AWG16 WHITE WHITE CM UL3271 AWG16 BLACK BLACK EMI FILTER 1 BLACK 3 BLACK CN30 B2P3-VH-B-C 2 W3 B BLACK 4-WAY VALVE EMI FILTER EARTH TERMINAL UL3271 AWG14 Wire w/TERMINAL ( CORE ) 1015#22 GREEN FRAME FRAME THERMISTOR ( PIPE TEMP. ) BLACK 2 3 BROWN THERMISTOR ( PIPE - MID. TEMP. ) W5 1 W6 1 BROWN RED 2 4 BLACK WHITE 5 WHITE 6 YELLOW 7 BROWN 1 RED CN71 B04B-PASK-1 DC FAN MOTOR 3 CN800 B5 ( 7-2.3 ) B-XASK-1-A WHITE FM 4 BLACK 1 2 CN70 B03B-PASK-1 BLACK 3 WHITE BROWN 1 BROWN 2 CN73 B02B-XAMK-1-A BLACK 1 BLACK 2 THERMISTOR ( OUTDOOR TEMP. ) THERMISTOR ( COMPRESSOR TEMP. ) ORANGE WHITE BLACK THERMISTOR ( DISCHARGE TEMP. ) UL1015 AWG14 UL3271 AWG14 W11 W10 B B 2011.11.11 EMI FILTER RED GREEN CONTROLLER PCB ASSEMBLY AOYG12LALL : K06AX-1104HUE-C1 AOYG14LALL : K06AX-1105HUE-C1 AOYG18LALL : K06AX-1106HUE-C1 CN40 B6B-XARK-1-A CN72 B2B-XH-AM RED WHITE 10 2 BROWN 3 BLUE 4 ORANGE 5 YELLOW 6 WHITE EXPANSION VALVE PMV EARTH + 1 - 4 W5 R1 ORANGE ZPR0RCH400 D101 LL25XB60 2 + Q100 GT30J121 R400 - R407 0.2 <1W> 1% x 8 + 3 R102 47k 1 + F4 3.15A 250V + 2 1 C103 0.1 R104 220k <2W> FH1 FC51FL x 2 + + + DCV-F D203 ZP1027-TP C5 0.01 2 3 C6 3.3 + I C200 FSBB20CH60 1 VCC NU 21 R201 330k 4 R202 330k 2 COM 5V 15V I C103 15V 3 IN R126 BAYPASS CAPACITOR POW_GND C119 W6 NV 22 4 IN 100k W2 5V-2 ORANGE L130 15V 5 IN 0.1 WHITE 3 4 SA1 1% I PM-G L100 R109 R108 6 VFO CAL45VB470K 12V RA-302M 2 1 U V DCV W BL02Rn1 7 CFOD NW 23 PR/I C80-5 D105 22 47 2 1 I C103-1 8 CSC C139 + C140 <1/4W><1/4W> 15V-2 C120 DAN217U 9 IN BA4560 K1 0.1 2.2/ 3 0.1 U 24 2 10 VCC 1 GAT I N 2 C104 1 DX12D1 W3 50V VCC 11 VB 3 5 SI 6 + 10/ -12V R153 120k GREEN -12V SO 12 VS 7 DI R105, R106 R127, R128 R129 HYIC1 1% R125 R120 C138 C137 R155 25V V 25 13 I N 3 NC GND 4 I C103-2 195k 10k 1% 100k GK-30434E3 14 VCC 4.7k 5V 2.2/ 0.1 100k R121 4.7k C105 6 BA4560 6 1% x 2 5V 7 15 VB x2 1% 7 50V 100k 1% PFC/58P I C100 5 0.1 R218 5 W 26 16 VS R122 R142 5V 1% TA8316 4.7k 17 I N R157 + DCV I C3-2 R156 4.7k 1.2k 18 14 10 5 4 3 2 1 18 VCC R124 <1/10W> W4 2 4.7k BA4560 100k 1% 1% 3 2 6 8 7 5 4 1 RED P 27 19 VB 7 1 4.7k 11 + 1 3 5V 390 <1/10W> x 6 R107 1% x 2 I C101 + 13 20 VS 6 R21 R23 10 5V 3.83k R204 TC74HC00AF R154 R131 R130 I C3-1 R20 I C102-2 R123 U/50P 10k 27k I C102-4 R210 1% 1 120k 10 14 220 BA4560 BA2901F 4.7k <1/10W> 1.0k <1/10W> R205 BA2901F 2 5V <1/10W> 1% R211 V/52P 13 1.0k <1/10W> C113 1% ZXL/37P C117 12 3 R171 POW_GND 1% R206 2700p 11 4 W/54P R212 1.0 4.7k PFCSW/35P S I/48P C214 3 3 R132 10 5 PFCEN/14P R207 2200p X/51P C20 R22 C21 9 6 3 2.2k SO/I C80-2 PFC-TR I P/46P R213 8 7 0.1 1.0k 0.047 1 2 1 2 2 R208 R167 Q102 Y/53P <1/10W> R214 10k C142 DTC143EUA D115, D114 R209 Z/55P I PM-G 0.1 DAN217U x 2 5V-2 5V JM32 1 3 R101 C106 0.1 5V-2 R215 5V-2 D106 15V PFCEN/14P I PM-TR I P/33P 4.7k 2 DAN217U R116 R115 CR30 1 C213 R216 R219 C219 K30 C141 15k 22k I C300 2 1 Q103 R113 RE1201 C110 0.022 2=3 C306 BAYPASS CAPACITOR R118 1.0k 1000p G5NB-1A 1% 1% R147, R150 DTC143EUA 4.7k 1 0.1 / 120 0.1 1000p JM30 JM31 R217 R110 0.1 D107 10k 2 3 R148, R151 3 1% 5 9 6.8k RB751V 1% + C206 - C208, C215 - C217 R329 2 + 14 12V 195k 4 R220 4 1 - 8 15V I C105 V4-AC/I C80-3 0.15 2200p x 6 1% x 4 I C102-3 47k I PM-G 5V 1.0k BAYPASS CAPACITOR C305 I C102-1 C108 + C107 R117 R119 <1W> BA2901F 1% C130 0.1 5V BA2901F 2.2/ 0.1 22k 10k 1% x 7 R162 2 1 R112 5V D301 0.1 50V D302 R328 1% 1% I C300-1 68k 10k R327 R163 DAN217U R160 R330 -12V D110 15V RB751V 1.0k BA4560 1% 1% 3 2 22k C136 R114 R111 10k 68k I PM-CR/9P 1 DAN217U 3 R159 0.01 15k 10k 1% 1% 15V DCV/8P 3 2 1 C111 4.7k C320 + ZXH/36P 1% 1 R332 C311 R331 R305, R303, R301 2 4700p C112 +C109 0.15 1000p 4.7k 1% I C102 I PM-G 47k R306, R304, R302 2.2/ 3 0.1 BAYPASS CAPACITOR C129 R161 I C105-1 6 x2 1% 195k R164 7 I C105-2 R165 50V 1000p 1.5k BA2903F 5 W V U 1% x 6 5 5V 22k 22k BA2903F + 7 1% 15V 2 1 5V - 6 I C300-2 DCV-F POW_GND POW_GND CT/3P D111 R339 1 5V 5V R337 DAN217U 5V BA4560 15V C125 C128 10k C127 + R801 3 3 100k +C126 R137 10k 1% R136 10k 1% 2 0.1 0.1 2.2/ L800 R334 2.2/ 1.0k 1% D112 3 R143 R307 -12V 50V R134, R133 BL02Rn1 10k 50V <1/4W> 3 R138 10k 1% DAN217U 1 2 R335, R336, R333 39k 2 195k 10k 1% x 2 1% Q801 1 FANPWM/2P C802 R144 3 10k 1% x 3 D109 1% R140 DTA143EUA 2 2 R802 5V R135 C800 + 0.1 22k 2 1 Q300 RB751V 10k 3 5V I C104-1 Q800 560 10k 100/ 1% 3 R168 R169 1 DTC114EUA I 302-1 1% 9 BA2902F R338 C330 C339 R340 DTC143EUA <1/4W> 8 1% 25V 6 R308 22k 22k 2 1 4 10 2 7 BA2903F 0.01 10k 1 5 1 3.3k 1000p ACV/7P D600 I C104-3 3 195k C123 5 R145 1% 1% 15V 5V POW_GND DAN217U I C104-2 D108 BA2902F D304, D303 3 2200p 22k C134 C132 C133 6 C131 15V DAN217U x 2 3 FAN I N/17P BA2902F RB751V + + C115 5V D113 1% 0.1 2.2/ 2.2/ 0.1 R146 R139 R804 R803 C801 R141 0.1 DAN217U 50V 50V 39k 10k 1 2 1.0k 10k 0.01 10k 13 I C104 R149 C124 C85 + 1 R81 2 1 2 14 1% 1% BAYPASS CAPACITOR 12 <1/10W> 1% C86 4.7k 2200p 10/ 1.0k 470p C116 1% 25V I C104-4 <1/10W> 3 3 0.1 6 BA2902F R152 COMP CP-POS/47P 7 5 4.7k -12V COMP R309 C300 R83 1% I C302-2 C84 5V 5.76k 100p 27k R311 BA2903F 0.1 1% <1/10W> 5V 8.66k R310 C580 C87 1% R503 R581 R582 R583 R584 143 0.1 330p 10k 22k 10k 1.0k DCV-F 10k 15V I C500 1% 12V 12V R500 R502 I C40 R40 - R43 MB90460 10k 1.0k JM500 TD62064 L40 1.5k <1/10W> x 4 TTXD/60P FAN I N/17P 17 P63 VCC 56 D50 1 2 O1 3 R52 EPV3/44P 16 AVCC P62 11 I1 TRXD/61P 7 O2 6 1SS355 T60 R56 EPV4/43P FANPWM/2P C52 2 P46 P00 25 2 15V 470k I2 9 O3 11 D60 EPV2/42P TMODE/18P 35 P12 P01 26 PFCSW/35P RPZ-1F I3 <1/8W> 150k 2200p 3 16 O4 14 D1FL20U EPV1/45P CT/3P 3 P50 P17 40 E2SK/40P I4 <2W> /TRES/19P 1% 4 GND1 1 10 1 TEST/59P 59 P37 P13 36 ZXH/36P 4 5V COM1 5 GND2 8 9 2 PFC/58P R14 ZXL/37P 58 P36 P14 37 R585 R53 COM2 + C64 5 12 GND3 10 8 3 TTXD/60P P15 60 P40 38 NC1 D51 C40 2.2k 1.0k 510k 330/ 12V D61 13 GND4 15 7 4 TAUX3/21P E2D I/39P 21 MD2 P16 39 6 NC2 UDZS8.2B 0.1 1% <1/8W> 6 5 25V R57 I C570 D1FL20U 5V 34 P11 AVR 12 I C10-1 CTDW/34P 5V 1% 0R0 EPV1/45P 47 P26 P24 45 M93C46 CP-POS/47P R16 R17 C12 BA2903F D63 27 P02 P25 46 V4-AC/27P PFC-TR I P/46P R13 R54 1 E2CS/41P 1 CS VCC 8 15V R18 2.2k 2.2k 0.1 C570 + C65 R61 5V U/50P ACFAN/28P 28 P03 P30 50 1SS355 L50, L51 10k D62 E2SK/40P 2 SK DO 4 510k R10 470/ 10k 2 I C60 1% 1% 3 29 P04 P31 51 X/51P 0.1 V4-DC/29P 10k BLm21 R50 E2D I/39P 3 DI NC 7 D1FL20 CTDW/34P + 1 <1/8W> 4.75k 25V 30 P05 P32 52 V/52P LED/30P BA7805 1 I 2 D53 6 NC GND 5 O 3 0R0 31 P06 P33 53 Y/53P PR/31P 1% 1% TH/10P C14 C13 R19 G 1 UF4005 6 x2 32 P07 P34 54 W/54P SO/32P 7 R12 0.1 0.1 1.0k C10, C11 2 C67 C68 + C66 R11 R55 5 2 Z/55P 33 P10 P35 55 I PM-TR I P/33P C572 C574, C573 + 13k 0.1 P60 14 57 C 0.1 100/ 100/ 10k 510k R570 I C10-2 PFCEN/14P 1.0k 1000p E2CS/41P 41 P20 P61 15 x2 I C50 5V 1% D52 25V 25V <1/8W> 10k C71 BA2903F <1/10W> x2 TMODE/18P 42 P21 MD0 18 EPV2/42P R75 TOP243PN 1SS355 L70 1 1% 0.1 EPV4/43P 43 P22 MD1 20 12V BL02Rn1 10k S 8 1 M 5V MD1/64P 44 P23 P44 64 2 TE/5P EPV3/44P R93, R92, R91, R90 R51 D80 2 S S 7 10 P57 P43 63 TH/10P MD2/63P I C80 10k x 4 + C69 R71 4.75k C51 3 D64 3 S I PM-CR/9P P56 P42 9 47 62 R80 SLR-332 100/ uLN2003 1% 1.0 D 5 4 C TD/4P DCV/8P TRXD/61P 8 P55 P41 61 1SS355 4 2.2k 25V C50 ACV/7P LED/30P MD0/1P 7 P54 P45 1 1B 1 16 1C + R76 C72 R72 TE/5P SO/I C80-2 /TRES/19P SO/32P 5 P52 RSTX 19 15 2C 2B 2 47/ JM101 MD0/1P 1 0.1 10k V4-AC/I C80-3 6 P53 P27 48 TA/6P V4-AC/27P S I/48P 13k 14 3C 3B 3 35V MD1/64P JM102 V4-DC/29P TD/4P 4 P51 AGND 13 13 4C 4B 4 2 1% -12V MD2/63P R560 5V R561 JM103 PR/31P GND 24 22 X0 PR/I C80-5 12 5C 5B 5 TEST/59P TA/6P 3 100k 1.0k ACFAN/28P 11 6C 6B 6 GND 49 23 X1 JM100 TEST 2 VDD NC 3 POW_GND 3 1 10 7C 7B 7 C500 R77 C75 1 OUT GND 4 12V 9 COM E 8 0.1 10k 0.1 X500 C561 C502 + I C560 8.00MHz 0.01 0.1 R73 C73 2 S80842 38.3k 0.1 1% C501 C503 10/ 0.1 25V - 3 - + - - + + - CN30 B2P3-VH-B-C BLACK 4-WAY VALVE COIL R158 3.9k R166 3.9k + SERIAL - + - + - - + - + - + WHITE + CN801 B5P6-VH-B-L DC FAN MOTOR - + - + CN73 B02B-XAMK-1-A GREEN THERMISTOR ( COMPRESSOR TEMP. ) CN72 B2B-XH-AM THERMISTOR ( PIPE - MID. TEMP. ) CN71 B04B-PASK-1 THERMISTOR ( PIPE TEMP. ) THERMISTOR ( DISCHARGE TEMP. ) CN70 B03B-PASK-1 THERMISTOR ( OUTDOOR TEMP. ) 2011.10.24 - RED + CN40 B06B-XARK-1-A ELECTRIC EXPANSION VALVE V W W7 W8 W9 C222 1.0 3 R2 220k <2W> U L300 CAL45VB470K D202 C220 47 / 35V 4 C4 0.01 D200 R203 330k N 2 FH2 C209 - C211, C212, C221 0.1 x 4 C200 47 / 35V VA2 470V 1 R103 100 <1/2W> US1J x 3 D201 C202 47 / 35V L C1 1.0 D102 UF4007 D100 LL25XB60 C204 47 / 35V RED C203 0.1 W11 C205 0.1 W10 WHITE 15V R200 39 <1/2W> DCV L1 RCH4716-070PF07 BLACK VA1 470V F100 15A 250V REACTOR C201 0.1 C100 - C102 660uF / 450V x 3 POWER SOURCE AC230V 50Hz W1 11 OUTDOOR UNIT CONTROLLER PCB ASSEMBLY AOYG12LALL : K-06AX-1104HUE-C1 AOYG14LALL : K-06AX-1105HUE-C1 AOYG18LALL : K-06AX-1106HUE-C1 Indoor unit OPERATION TIMER lamp lamp (green) (orange) : 0.5s on / 0.5s off (1) (1) : 0.1s on / 0.1s off (1) (2) (1) (5) (2) (1) (2) (2) (2) (3) ( ) : Number of flashing ER R OR D ETEC TION INDOOR UNIT and WIRED REMOTE CONTROL If you use a wireless remote control, the lamp on the photo detector unit will output error codes by way of blinking patterns. If you use a wired type remote control, error codes will appear on the remote control display. See the lamp blinking patterns and error codes in the table. An error display is displayed only during running. This is possible only on a wired remote control. If an error occurs, the following display will be shown. (“Er” will appear in the set room temperature display.) Error code 12 Wired remote control Description Serial communication error Wired remote control communication error Check run unfinished Unit number or Refrigerant circuit address setting error [Simultaneous Multi] Indoor unit capacity error Combination error (2) (4) • Connection unit number error (indoor slave unit) [Simultaneous Multi] • Connection unit number error (indoor unit or branch unit) [Flexible Multi] (2) (7) Master unit, slave unit set-up error [Simultaneous Multi] (3) (2) Indoor unit PCB model information error (3) (5) (4) (1) (4) (2) (5) (1) (5) (3) (5) (7) (5) (15) (6) (2) (6) (3) (6) (4) (6) (5) (6) (10) (7) (1) (7) (2) (7) (3) (7) (4) (7) (5) (7) (6) (7) (7) (8) (2) (8) (3) (8) (4) (8) (6) (9) (4) (9) (5) (9) (7) (9) (9) (10) (1) (10) (3) (10) (4) (10) (5) (13) (2) EX. Self-diagnosis 2011.02.10 ECONOMY lamp (green) Manual auto switch error Inlet air temp. sensor error Indoor unit Heat Ex. Middle temp. sensor error Indoor unit fan motor error Drain pump error Damper error Indoor unit error Outdoor unit main PCB model information error or communication error Inverter error Active filter error, PFC circuit error Trip terminal L error Display PCB microcomputers communication error Discharge temp. sensor error Compressor temp. sensor error Outdoor unit Heat Ex. liquid temp. sensor error Outdoor temp. sensor error Suction Gas temp. sensor error • 2-way valve temp. sensor error • 3-way valve temp. sensor error Heat sink temp. sensor error • Sub-cool Heat Ex. gas inlet temp. sensor error • Sub-cool Heat Ex. gas outlet temp. sensor error Liquid pipe temp. sensor error Current sensor error • Discharge pressure sensor error • Suction pressure sensor error • High pressure switch error Trip detection Compressor rotor position detection error (permanent stop) Outdoor unit fan motor error 4-way valve error Discharge temp. error Compressor temp. error High pressure error Low pressure error Branch boxes error [Flexible Multi] OUTDOOR UNIT 2008.07.25 Error contents LED Thermistor malfunction on 0.1 sec / off 0.1 sec Abnormal discharge temperature on Current surge protection on 0.5 sec / off 0.5 sec CT abnormality on 2.0 sec / off 2.0 sec Compressor position detection malfunction on 0.1 sec / off 2.0 sec Fan malfunction on 5.0 sec / off 5.0 sec PAM voltage abnormality on 5.0 sec / off 0.1 sec Timer short on 1.0 sec / off 1.0 sec Compressor temperature protection (permanent stop) on 2.0 sec / off 5.0 sec PFC surge protection (permanent stop) on 5.0 sec / off 2.0 sec 13 8 PARTS 8 11 11 DECORATION PANEL UTG-UFYD-W 1 5 8 10 8 9 3 2 4 2011.12.12 7 Ref. Description 6 14 Part number 1 Decoration Panel 9375525040 2 Display Panel 9375529123 3 Receiver Window 9375547011 4 Intake Grille 9375531027 5 Long Life Filter 9375533014 6 Hook Bracket 9375546014 7 Grille Hook 9375532024 8 Panel Cover 9375530013 9 Indicator PCB Assy 9707371031 10 Connector Cover 9375549015 11 Flap Total Assy 9377760029 DECORATION PANEL UTG-UFYD-W Flap total assy Motor holder assy 21 22 23 (connector : white) (connector : red) 2011.12.12 24 Ref. Description Part number 21 Gear A 9375536015 22 Motor Holder 9375535018 23 Step Motor 9900139070 24 Step Motor 9900139087 15 3 1 PARTS INDOOR UNIT 6 8 2 4 5 7 9 Ref. Description 12 10 11 2011.12.12 16 Part number 1 Top Plate Assy 9375490027 2 Cabinet A Assy 9375492014 3 Cabinet B 9375494018 4 Hook R 9375504014 5 Hook L 9375505011 6 Insulation Box Assy 9377764065 7 Wire Cover 9375516017 8 Pipe Cover 9375515010 9 Bell Mouse 9375503017 10 Wire Holder 9375478018 11 Drain Pan Sub Assy 9377765024 12 Drain Cap 9375502010 23 22 21 23 26 25 27 24 30 31 29 32 28 INDOOR UNIT Ref. Description Ref. Description Part number Part number 21 Separate Wall 9375506018 27 Fan Motor Holder 9375552015 22 Evaporator Total Assy (12) 9377914033 28 Pump Assy 9900472030 22 Evaporator Total Assy (14, 18) 9377914026 29 Drain Pump Holder B 9375518011 23 Evaporator Holder 9375508012 30 Rubber (Pump) 9378426016 24 Turbo Fan Washer 9375487010 31 Float Switch 9900361037 25 2 Stage Turbo Fan Assy 9375480011 32 Drain Port Sub Assy 9375718015 26 Fan Motor 9602436019 2011.12.09 17 41 INDOOR UNIT Control unit 42 46 44 43 45 Ref. Description 47 48 2011.12.12 18 Part number 41 Control Box Cover 9375512019 42 Control Box A 9375511012 43 Controller PCB Assy (12) 9707393927 43 Controller PCB Assy (14) 9707393934 43 Controller PCB Assy (18) 9707393941 44 Power Supply PCB Assy 9707398250 45 Terminal 9306489045 46 Terminal 9703345012 47 Remote Control 9379219006 48 Remote Control Holder 9305642045 -- Pipe Thermistor 9703297014 -- Room Thermistor 9900502003 2 P ART S OUTDOOR UNIT 14 1 6 15 11 13 8 10 Ref. 12 7 5 Description Part number 1 Protective Net 9315319036 2 Top Panel Assy 9309230057 3 Fan Guard Cover 9378110014 4 Cabinet Assy 9312799404 5 Switch Cover 9315039019 6 Cabinet Right Assy 9309236059 7 Valve Cover 9316884007 8 Valve Bracket 9308870070 9 Separator Assy 9312971015 10 Reactor Assy 9900641016 11 Motor Bracket Assy 9313432010 12 Fan Motor 9601725015 13 Propeller Fan 9309909014 14 Inverter PCB Assy (12) 9707427530 14 Inverter PCB Assy (14) 9707427547 14 Inverter PCB Assy (18) 9707427554 15 Terminal 9703874031 9 4 3 2011.12.12 19 23 OUTDOOR UNIT 25 24 22 26 27 37 29 28 21 30 31 32 Ref. Description Part number Ref. Description Part number 21 Base Assy 9308869081 28 Solenoid 9970033018 22 2-way Valve Assy 9970093012 29 4-way Valve Assy 9315311030 23 Expansion Valve Coil 9900057039 30 3-way Valve Assy 9970092015 24 Pulse Motor Valve Assy 9311641018 31 Compressor Assy 9313763039 25 Condenser Total Assy 9311381068 32 Compressor Thermistor 9900156046 26 Heat Exchanger Thermistor 9900403010 -- Outdoor Thermistor 9900210045 27 Thermistor Assy 9900148027 -- Drain Assy 9303029015 2011.12.12 20 ACCESSO RI ES DECORATION PANEL INDOOR UNIT Name and Shape Q’ty Application Name and Shape 1 For indoor side pipe joint (Gas pipe) Connector cover 1 For indoor side pipe joint (Liquid pipe) Coupler heat insulation Special nut A (Large flange) Tapping Screw (M5 × 12 mm) 4 4 4 Tapping Screw 1 For installing indoor unit L angle 2 Template (Carton top) 1 For mounting decoration panel For installing indoor unit (M4 × 12 mm) Special nut B (Small flange) For covering connector 1 (Large) Coupler heat insulation (Small) Q’ty Application For cealing openings cutting Also used as packing Hook wire 2 For mounting connector cover For mounting the Hook Wire to the Decoration panel For suspending the Decoration panel Drain hose For installing drain pipe Screw [pitch small] 1 For mounting the Hook Wire (for metals) (M4 × 10 mm) 2 Hose Band For installing drain hose 1 Screw [pitch large] (M4 × 10 mm) Drain hose insulation 1 4 For mounting the L angle and Hook wire (for resins) For installing drain pipe Remote control For air conditioner operation OUTDOOR UNIT 1 Name and Shape Q'ty Application Drain pipe Battery 2 Remote control holder 1 For installing the remote control 2 For mounting the remote control holder Binder 2 Wire clamper 1 2011.12.12 For remote control Adapter assy Tapping screw (M3 × 12mm) 1 1 For drain piping work. 9303029015 To connect 12,000 BTU model 9370244007 For electrical wiring For electrical wiring 21