Preview only show first 10 pages with watermark. For full document please download

Fully Electronic

   EMBED


Share

Transcript

Voltage supply systems fully electronic Technical data Output voltage: Frequency: Power: Deviation: Adjustment: Control time: Load: Interface: Line voltage: Weight: 90-7F / 90-7G 0 .. 135 • 265 VAC 45 .. 400 Hz 220 / 500 VA ± 0.2% of meas. fully electronic max. 400 ms fully inductive/capacitive digital • Analog interface 230 VAC ± 10%; 49 .. 61 Hz 90-7F: 24 kg 90-7G: 36 kg Front view 90-7F Fully electronic AC voltage supply The unit provides a stable, frequency-controlled voltage supply to consumers. The unit can be operated manually at the front panel as well as via the interface. Current, voltage and frequency are displayed on digital instruments. Frequency is displayed on a four-digit digital display.For more detailed technical data, please see the table on back. Front view 90-7G Description Dimensions Item no. AC voltage supply 220 VA fully electronic 19" / 4HU 90-7F AC voltage supply 500 VA fully electronic 19" / 6HU 90-7G for device type Item no. Extensions for the testing devices Technical data Interface On request 90-7F Interface On request 90-7G Other voltage ranges On request Other current ranges On request Calibration Elabo works calibration 90-7F 90-7F E99 Calibration Elabo works calibration 90-7G 90-7G E99 The description of the accessories can be found in the description starting on page 108. Technical specifications subject to change without notice. 105 Device features 90-7F / 90-7G Device Applications Manual use Automated use Operation Digital display voltage 3 digits Digital display frequency 4 digits Potentiometer for voltage setting Potentiometer for frequency setting Fuses at front Power switch at front Digital interface Analog input 0 .. 10 VDC (setting) Connections Socket on front Laboratory receptacles at front Output voltage Voltage range 1 Current range 1 Voltage range 2 Current range 2 Max. Power Frequency Principal technical data Mains connection Mains frequency Dimensions – depth 360 mm Weight Allowable humidity Working temperature Adjustment speed Deviation of adjustment 90-7F 90-7G l l l l l l l l l l l l l l l l l l l l l l l l 5 .. 135 V 0 .. 1.63 A 0 .. 3.7 A 5 .. 265 V 0 .. 0.83 A 0 .. 1.88 A 220 VA 500 VA 45 .. 400 Hz 230 V ±10 % 49 .. 61 Hz 19“ / 4 HU 19“ / 6 HU 24 kg 36 kg 25 .. 75 % rel. 10 .. 45 °C Max. 400 ms ± 0.2 % of meas. l Standard  Optional Technical specifications subject to change without notice. 106 fully electronic