Preview only show first 10 pages with watermark. For full document please download

Functional - Yorkland Controls

   EMBED


Share

Transcript

Functional Devices, Inc. APPLICATION MANUAL 2005 RIB ® By Yorkland Controls www.yorkland.net Feel free to contact Yorkland Controls at 1-877-733-3833 RELAY & CURRENT SENSOR IN ONE 1 Directly start/stop load and current sensing all in one package. (No external ring is needed) Controller Digital Out Load Start/Stop Relay Current Sensor Circuitry Solid State Transducer Switch Digital In INTERNAL 20 AMP INTERNAL 10 AMP INTERNAL 5 AMP RIBX24BF RIBX24SBF RIBX24BA RIBX24SBA RIBXLCF RIBXLSF RIBXLCA RIBXLSA RIBXLCEA RIBXLSEA 60 Hz ac MOTOR STARTER 2 Allows relay to control a motor starter while sensing current flowing to the motor. EXTERNAL SENSOR RING 3-Phase Line Voltage MOTOR STARTER CONTROLLER Digital Out MOTOR RIBXLCRA RIBXCLRF RIBXLSRA RIBXLSRF 24 Vac EXTERNAL SENSOR RING Start/Stop Relay Current Sensor Circuitry Digital In Solid State Switch Transducer SENSOR ONLY FOR 1.25 AMP TO 150 AMP LOAD 3 Use sensor only devices without relay where start/stop is not required. EXTERNAL SENSOR RING 3-Phase Line Voltage MOTOR STARTER MOTOR CONTROLLER Digital Out Current Sensor Circuitry Digital In 2005 Solid State Switch RIBXRA RIBXRF RIBMXRA RIBMXRF EXTERNAL SENSOR RING Transducer APPLICATION MANUAL AM578B www.yorkland.net PAGE 1 PANEL MOUNTED RELAY & INTERNAL SENSOR 4 Start/Stop Relays with Internal Current Sensors measure current flow through the relay contacts, no external ring is needed. Senses current as low as .50 mA. INTERNAL 20 AMP PANEL RIBMX24BF RIBMX24SBF RIBMX24BA RIBMX24SBA CONTROLLER 5 or 20 Amp MAX LOAD Digital In Digital Out RIBMX Start/Stop Relay Current Sensor Circuitry Solid State Switch Transducer 60 Hz ac INTERLOCKING LOADS 5 Some RIBX current sensor relays can be used to sense 1 or more loads to turn on another. Laundromat Exhaust Fan 60 Hz ac 24 Vac Source RIBX Start/Stop Relay Current Sensor Circuitry Solid State Switch EXTERNAL SENSOR Dryer 1 Transducer EXTERNAL 10 AMP RIBXLCRF RIBXLCRA RIBXLCJF RIBXLCJA RIBXLSRF RIBXLSRA RIBXLSJF RIBXLSJA Dryer 2 INTERLOCKING LOADS (NO TRANSFORMER) 6 Self-powered Current Sensors of the RIBX Series and relays of the Dry Contact Input RIB Series may be applied to interlock Load 2 to Load 1. Current sensing may be internal or external LOCAL POWER 120, 240, 277 Vac LOAD 1 LOAD WIRE RIBX SERIES Low Voltage (Class II) Current Sensor Only Current Sensor Status DRY CONTACT INPUT RIB SERIES DRY CONTACT INPUT RELAYS CURRENT SENSORS RIB21CDC RIB01BDC RIB01SBDC RIB02BDC RIB02SBDC RIBM01ZNDC RIBM02ZNDC RIBM013PNDC RIBXKF RIBXKTF RIBXKA RIBXKTA RIBXGA RIBXGF RIBXGTA RIBXGTF RIBXGFL RIBXGTFL RIBXF RIBXA LOAD 2 APPLICATION MANUAL AM578B 2005 RIBXRF RIBXRA RIBXJF RIBXJA RIBMXF RIBMXA RIBMXRF RIBMXRA RIBMXJF RIBMXJA G DAMPER MOTOR CONTROL 7 Damper motor control with true-HOA. The damper motor can be stopped in mid position for debugging. When auto/manual selector is in auto, relay controls the load. When in manual, use the manual switch to control the load. 24 Vac From Controller Auto / Manual Selector Wh/Blu Auto Line (120 Vac) Man Wh/Yel Manual Switch Wh/Blk (not used) Open N/C Closed Open (120 Vac) ORANGE N/O Closed YELLOW Damper Motor Neutral BLUE 10 & 15 AMP 20 AMP RIBU1SC RIBH1SC RIBTU1SC RIBTH1SC RIBMU1SC RIBMH1SC RIB2401SBC RIB2402SBC RIBT2401SBC RIBT2402SBC RIBM2401SBC RIBM2402SBC Close (120 Vac) RIBU1S VS. RIBU1SC 8 Stock model RIBU1SC for relay control applications that require true-HOA on either N/O or N/C. No jumpers and no wrong orders. RIBU1S has a lower cost but if N/C is desired on relay, it must be specified when ordering. 120 Vac 24 Vac From Controller Orange Wh/Blu RIBU1S Wh/Yel Orange LOAD RIBU1SC is an alternative to the RIBU1S that allows one item to be ordered - no need to specify N/O or N/C. 120 Vac 24 Vac From Controller Wh/Blu RIBU1SC Wh/Yel Yellow Orange (N/O) 10 & 15 AMP 20 AMP RIBU1SC RIBH1SC RIBTU1SC RIBTH1SC RIBMU1SC RIBMH1SC RIB2401SBC RIB2402SBC RIBT2401SBC RIBT2402SBC RIBM2401SBC RIBM2402SBC LOAD Blue (N/C) N/O or N/C, you choose DRY CONTACT INPUT RELAYS 9 Does not require a transformer to power the relay. Safe, low voltage, Class II wiring can be run to a dry contact switch on the door (or any place desired). Class II Wiring RIB21CDC 120 Vac Power Light Fixture Junction Box Closet Light Line Neutral Class II Wiring Dry-Contact Door Switch Closet Door RIB21CDC BLACK YELLOW RED ORANGE ENCLOSED RELAYS TRACK RELAYS RIB21CDC RIB01BDC RIB01SBDC RIB02BDC RIB02SBDC RIBM01ZNDC RIBM02ZNDC RIBM013PNDC Light Fixture Junction Box Blue (Not Used) 2005 APPLICATION MANUAL AM578B www.FUNCTIONALDEVICES.com PAGE 3 10 LIMIT EXTRA TRANSFORMERS WITH DRY CONTACT INPUT RELAYS Eliminate the expense of extra transformer(s) and associated wiring. BEFORE Enclosure D Controller R Cont. Pwr. Y C O N T A C T S 120 Vac 24 Vac 40 VA 24 Vac 100 VA D.O.1 D.O.2 Enclosure Controller C O N T A C T S 11 ENCLOSED RELAYS TRACK RELAYS RIB21CDC RIB01BDC RIB01SBDC RIB02BDC RIB02SBDC RIBM01ZNDC RIBM02ZNDC RIBM013PNDC D.O.3 AFTER D R Y RIBU1C's Dry Contact Input RIB's 120 Vac 24 Vac Cont. Pwr. 40 VA D.O.1 D.O.2 D.O.3 DETECT WATER LEVELS WITH DRY CONTACT INPUT RELAYS If the water touches the wires, the relay will turn on (closes COMMON to N/O and opens COMMON to N/C). Uses UL Approved low-voltage to sense water and activate relay. Dry Contact Input Relay CONTROL CIRCUIT 120-277 Vac Power R E L A Y LOAD TRACK RELAYS RIB21CDC RIB01BDC RIB01SBDC RIB02BDC RIB02SBDC RIBM01ZNDC RIBM02ZNDC RIBM013PNDC Any typical non-corrosive probes may be used. Water Pan 12 ENCLOSED RELAYS MONITORING SWITCH POSITION WITH A CONTROLLER Digital In 1 and 2 of the controller can be used to monitor the position of the HOA switch. The controller can be programmed to log the status of the HOA and provide a warning if the switch is in an override position. CONTROLLER Digital Out Common 10-30Vac/dc Common RIB 60 Hz ac 120 Vac Not Used Digital In 1 Digital In 2 Common PAGE 4 Closed SWITCH Auto Pole #2 Common SWITCH Pole #1 Auto Common ENCLOSED RELAYS 10 AMP TRACK RELAYS 15 AMP RIBU1SM RIBH1SM RIBMU1SM RIBMH1SM RIBMNU1SM RIBMNH1SM LOAD www.FUNCTIONALDEVICES.com DI1 Open Open Closed Closed DI2 Open Closed Open Closed RESULT Overridden Off Auto Overridden On Error Condition APPLICATION MANUAL AM578B 2005 HIGH VOLTAGE OPTOISOLATED RELAYS 13 Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs. 60 Hz ac CONTROLLER Power Supply Digital Out (or Analog Out) Opto Input R E L A Y LOAD ENCLOSED RELAYS TRACK RELAYS RIBTE01B RIBTE02B RIBTE01SB RIBTE02SB RIBTE01P RIBTE02P RIBME2401B RIBME2402B RIBME2401SB RIBME2402SB RIBME2401P RIBME2402P OPTO RIB 14 LOW VOLTAGE OPTOISOLATED RELAYS Optoisolated relays help isolate noisy loads from the controller. Good for controlling power relays from analog outputs. 60 Hz ac CONTROLLER Power Supply 24 Vac/dc Opto Input Digital Out R E L A Y LOAD ENCLOSED RELAYS TRACK RELAYS RIBTELC RIBTELS RIBTE24B RIBTE24SB RIBTE24P RIBME2401B RIBME2402B RIBME2401SB RIBME2402SB RIBME2401P RIBME2402P OPTO RIB 15 POLARIZED RELAYS For fire alarm systems, smoke control systems, etc. Relays are polarized to work in a supervised system and may be turned on and off by reversing polarity. LOAD LOAD RIB24C-FA RIB24C-FA +- +- ENCLOSED RELAYS TRACK RELAYS RIB12C-FA RIB24C-FA RIB24S-FA RIBT24B-FA RIB24P-FA RIBMN12C-FA RIBMN24C-FA RIBMN12S-FA RIBMN24S-FA END OF LINE RESISTOR CONTROLLER SIGNALING CIRCUIT 2005 APPLICATION MANUAL AM578B www.FUNCTIONALDEVICES.com PAGE 5 CONDENSE WORK SPACE & WIRING (POWER CONTROL) 16 Power Control Centers allow you to save large amounts of time, space, and wiring throughout your panel. BEFORE AFTER There is a lot of extra wiring in this enclosure which not only takes up space but also increases the difficulty and time associated with installation. By using one of Functional Devices' Power Control Centers you will greatly reduce installation time, as well as save space in your enclosure. CONDUIT ENCLOSURE ENCLOSED 10 AMP PSPT2RB4 PSPW2RB4 PSPT2RB10 PSPW2RB10 CONDUIT Power Control Center is pre-wired ENCLOSURE SWITCH To remainder of panel H N G H N G FUSE SUB-PANEL ENCLOSED 4 AMP SWITCH, BREAKER & INDICATOR LIGHT To remainder of panel SUB-PANEL CONDENSE WORK SPACE & WIRING (POWER SUPPLIES) 17 The PSC, PSH, and PSB Series Power Supplies allow you to save large amounts of time, space, and wiring throughout your panel. BEFORE By using one of Functional Devices' Power Supplies you will greatly reduce installation time, as well as save space in your enclosure. CONDUIT ENCLOSURE H N G H N G FUSE 24 Vac 18 To remainder of panel Any “B10” models in the PSC, PSH, or PSB Power Supply Series’ CONDUIT Power Supplies are pre-wired ENCLOSURE SWITCH SUB-PANEL POWER SUPPLIES AFTER There is a lot of extra wiring in this enclosure which not only takes up space but also increases the difficulty and time associated with installation. 24Vac Switch/Breaker 120Vac from 10A Switch & CB to remainder of panel 24Vac 24Vac Indicator POWER SUPPLY MAIN POWER 10A Switch/CB & Indicator Light SUB-PANEL SWITCH IN A BOX ENCLOSED CONTROLS Pre-labeled 20A switches are great for new installations or last minute corrections to controls jobs. Switch labels may be custom selected when ordering. 2 POSITION SUMMER WINTER COOL (Summer) HEAT (Winter) To A/C Power In 2 POSITION 3 POSITION SIB04S SIB05S SIB02S SIBLS 3 POSITION 24VAC HAND OFF AUTO CONTACTOR COIL CONTROLLER DIGITAL OUT PAGE 6 24Vac Transformer DO Front Controller Hand Off Auto Contactor Coil www.FUNCTIONALDEVICES.com APPLICATION MANUAL AM578B 2005 AM578B APPLICATION MANUAL 2005 www.FUNCTIONALDEVICES.com APPLICATION NOTES FOR RIB® RELAYS, CURRENT SENSORS, POWER SUPPLIES, & POWER CONTROL UNITS C