Fuse holder terminal blocks  ZZZHQWUHOHFUX   M 4/8.SF... Fuse holder terminal blocks for 5 x 20 mm and 5 x 25 mm fuses Compression clamp M 4/8.SFT Spacing 8 mm (.315") Spacing 8 mm (.315") Standard 8 mm block. M 4/8.SF equipped with two test sockets DIA. 2 mm/.079". DIN 1 - DIN 3 * Blocks with LED indicator are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required. ** Terminal block with low temperature surfacing : Storage -60°C Use -20°C BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Grey Grey ** Orange Beige V0 M 4/8.SF M 4/8.SF1.TS M 4/8.SF2 M 4/8.SF.V0 Characteristics Compression Solid wire clamp Stranded wire IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 630 V (1) 8 kV 3 600 V (1) 250 V 6,3 A 10 A 10 A Voltage Test plug Comb type jumper bar IDC jumper Assembly rod Current 6 Assembly ring 7 Fuses 5 x 20 mm 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 400 V (1) 4 kV 3 600 V (1) 250 V 6,3 A 6,3 A 10 A Compression Solid wire clamp Stranded wire Rated Pulse Pollution degree Rated 12 AWG Rated / Gauge Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 9,5 mm .37" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 9,5 mm .37" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 grey FEM8S orange FEM8S beige FEM8S 4 mm² / A4 12 AWG 4 mm² / A4 12 AWG Part numbers Type V2 V2 V0 35 A PC81 AD2,5 TGA8 th. 1,5 mm th. 1,5 mm th. 1,5 mm 0116 951.15 0103 923.15 0196 951.16 10 poles 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 2 poles 3 poles 4 poles ANT 250 V FU520 8 Disconnect link bar CSA Wire stripping length 5 0,5 1 2 3,15 4 5 5 1,6 2 2,5 4 6,3 Fuses 5 x 25 mm 250 V FU525 Fast fusion HPC 1500 A 8 UL Wire size 5 6 7 IEC NFC DIN Current 3 4 0115 662.22 0195 662.23 Voltage Rated Pulse Pollution degree Type 2 3 4 5 2 Part numbers M 4/8.SFT M 4/8.SFT.V0 Wire size Rated / Gauge 1 End section Type Grey Beige V0 Wire size Wire size Accessories 1 0115 657.25 0115 658.06 0105 135.11 0195 657.26 Characteristics Rated Block matching fuse terminal block M 4/8.SF for line, fuse applications, see page 137. Type Part number M 4/8 0115 523.07 Part numbers Color x 20 A A A A A A x 25 A A A A A CN5 FEM8S FEM8S FEM8S FC2 PC81 AD2,5 TGA8 Part numbers V2 V2 V0 ANT FU520 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0168 834.24 0008 292.01 FU525 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0179 371.16 th. th. th. DIA. 10 DIA. 2 3 4 1,5 mm 1,5 mm 1,5 mm 2 mm poles 2 mm poles poles poles 5 0,5 1 2 3,15 4 5 5 1,6 2 2,5 4 6,3 x 20 A A A A A A x 25 A A A A A CN5 R R See section on markers marking method 6 RC610 on grip 17 RC810 on side 12 AWG 6 RC610 on grip 17 RC810 on side Note : (1) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating. (2) Protection index for closed block.  ZZZHQWUHOHFUX   0116 951.15 0103 923.15 0196 951.16 0007 865.22 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0168 834.24 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0179 371.16 M 4/8.SF... M 4/8.SF...T... M 4/8.SN... Spacing 8 mm (.315") Spacing 8 mm (.315") Spacing 8 mm (.315") M 4/8.SF with blown fuse indicator. Grey body. M 4/8.SF with blown fuse indicator equipped with 2 test sockets DIA. 2 mm/.079". Grey body. M 4/8.SF with disconnect link bar locked on grey grip. Color Type Part numbers Color Neon lamp(3) M 4/8.SFL Diode LED 24 V* (4) M 4/8.SFD Diode LED 48 V* (4) M 4/8.SFD1 Diode LED 48 V (4)(5) M 4/8.SFD2 0115 661.21 0115 663.23 0115 664.24 0115 653.21 Type Characteristics Characteristics Wire size Wire size Compression Solid wire clamp Stranded wire IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 400 V (1) 4 kV 3 600 V (1) 250 V 6,3 A 10 A 10 A Voltage Part numbers Color Neon lamp(3) M 4/8.SFLT Diode LED 24 V* (4) M 4/8.SFDT Diode LED 48 V* (4) M 4/8.SFDT1 0115 667.27 0115 665.25 0115 666.26 Current Wire size Compression Solid wire clamp Stranded wire UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 400 V (1) 4 kV 3 600 V (1) 250 V 6,3 A 10 A 10 A IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 630 V 8 kV 3 600 V 250 V 6,3 A 10 A 10 A Compression Solid wire clamp Stranded wire Voltage Rated Pulse Pollution degree Rated Pulse Pollution degree Current Rated Wire size Rated / Gauge 0115 660.04 0105 136.12 0195 660.05 Wire size IEC NFC DIN Current Rated Part numbers M 4/8.SN1 M 4/8.SN2 M 4/8.SN1.V0 Characteristics Voltage Rated Pulse Pollution degree Type Grey Orange Beige V0 Rated Wire size 12 AWG Rated / Gauge 12 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 9,5 mm .374" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 9,5 mm .374" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 9,5 mm .374" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 4 mm² / A4 12 AWG Type 4 mm² / A4 12 AWG Part numbers Type FEM8S FEM8S FEM8S V2 V2 V0 PC81 AD2,5 TGA8 35 A 24 A ANT FU520 FU525 6 RC610 on grip th. 1,5 mm th. 1,5 mm th. 1,5 mm 0116 951.15 0103 923.15 0196 951.16 10 poles 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 2 poles 3 poles 4 poles 5 0,5 1 2 3,15 4 5 5 1,6 2 2,5 4 6,3 x 20 A A A A A A x 25 A A A A A FEM8S FEM8S FEM8S FC2 PC81 AD2,5 TGA8 12 AWG Part numbers Type V2 V2 V0 35 A 24 A ANT FU520 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0168 834.24 0008 292.01 FU525 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 17 RC810 on side 4 mm² / A4 6 RC610 on grip th. th. th. DIA. 10 1,5 mm 1,5 mm 1,5 mm 2 mm poles 2 poles 3 poles 4 poles 5 0,5 1 2 3,15 4 5 5 1,6 2 2,5 4 6,3 x 20 A A A A A A x 25 A A A A A 17 RC810 on side 0116 951.15 0103 923.15 0196 951.16 0007 865.22 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 12 AWG Part numbers FEM8S FEM8S FEM8S V2 V2 V0 PC81 AD2,5 TGA8 35 A 24 A th. 1,5 mm th. 1,5 mm th. 1,5 mm 0116 951.15 0103 923.15 0196 951.16 10 poles 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 2 poles 3 poles 4 poles ANT 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0168 834.24 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 6 RC610 on grip 17 RC810 on side Note : (3) Blown fuse indicator : neon lamp 110-230 V. Leakage current with neon lamp : < 0,5 mA (110 V) / < 0,7 mA (230 V). (4) Leakage current with LED 24 or 48 V : < 4,5 mA. (5) Block delivered with - on open side.  ZZZHQWUHOHFUX   M 4/8.SN Fuse holder terminal blocks for 5 x 20 mm and 5 x 25 mm fuses Compression clamp M 4/8.SNT Spacing 8 mm (.315") Spacing 8 mm (.315") M 4/8.SF with disconnect link bar locked on blue grip. M 4/8.SF with disconnect link bar locked on blue grip, equipped with 2 test sockets DIA. 2 mm/.079". DIN 1 - DIN 3 Color Type BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Characteristics Compression Solid wire clamp Stranded wire IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 630 V (1) 8 kV 3 600 V (1) 250 V 6,3 A 10 A 10 A Voltage Test plug Comb-type jumper bar IDC jumper Assembly rod Current IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 24-12 AWG 24-12 AWG 400 V (1) 4 kV 3 600 V (1) 250 V 6,3 A 10 A 10 A Compression Solid wire clamp Stranded wire Rated Pulse Pollution degree Current Rated Wire size 12 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 9,5 mm .37" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 9,5 mm .37" 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 (2) NEMA 1 4 mm² / A4 12 AWG 4 mm² / A4 12 AWG Part numbers Type grey FEM8S orange FEM8S beige FEM8S V2 V2 V0 35 A PC81 AD2,5 TGA8 35 A 24 A th. 1,5 mm th. 1,5 mm th. 1,5 mm 0116 951.15 0103 923.15 0196 951.16 10 poles 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 2 poles 3 poles 4 poles 3 6 Assembly ring ANT FEM8S FEM8S FEM8S FC2 PC81 AD2,5 TGA8 th. th. th. DIA. 10 35 A 24 A 1,5 mm 1,5 mm 1,5 mm 2 mm poles 2 poles 3 poles 4 poles ANT 6 R R See section on markers marking method 6 RC610 on lever 17 RC810 on side 12 AWG Part numbers V2 V2 V0 4 5 0115 668.00 0195 668.01 Voltage Rated Pulse Pollution degree Type 2 3 4 5 2 Part numbers M 4/8.SNT M 4/8.SNT.V0 Wire size Rated / Gauge 1 End section Type Grey body/Blue grip Beige body/Blue V0 grip Characteristics Wire size Accessories 1 0115 659.07 0195 659.00 Wire size Rated Block matching fuse terminal block M 4/8.SF for line, fuse applications, see page 137. Type Part number M 4/8 0115 523.07 Part numbers Color M 4/8.SN M 4/8.SN.V0 Grey body/Blue grip Beige body/Blue V0 grip 6 RC610 on lever 17 RC810 on side Note : (1) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating. (2) Protection index given for closed block.  ZZZHQWUHOHFUX   0116 951.15 0103 923.15 0196 951.16 0007 865.22 0173 523.11 0114 205.20 0168 672.11 0168 773.12 0168 674.13 0168 675.14 M 4/8 Standard terminal blocks Compression clamp Spacing 8 mm (.315") DIN 1 - 3 Note: For terminal block with matching profile to fuse block M 4/8.SF, use M 4/8 shown here. Terminal block compatible with fuse block M 4/8.SF Color Type Part number Grey M 4/8 0115 523.07 Characteristics Wire size BADL V0 0199 408.02 End stop th. 9 mm BAM 0103 002.26 End stop th. 9,1 mm 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 x 1,5 PR1Z2 0163 050.04 Other end stops and rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. NFC Compression Solid wire clamp Stranded wire DIN UL 0,2-4 mm² 0,22-4 mm² 22-12 AWG 22-12 AWG 500 V Gr.C 600 V 26 A 15 A CSA Voltage Rated Pulse Pollution degree Current Rated Wire size 4 mm² / A4 Rated / Gauge Accessories 1 End section 2 Separator end section 1 grey grey beige 3 Protective cover 4 Test socket 3 4 5 Test plug 6 Comb type jumper bar 35 A 7 IDC jumper 12 AWG Wire stripping length Recomm. screwdriver Recomm. torque Protection 9,5 mm .37" 4 mm .16" 0,5-0,8 Nm 4.4-7.1 lb.in IP 20 NEMA 1 Type FEM8S th. SCFCV3 th. SCFCV3 V0(1) V0 th. CPV3 (for SCFCV3...) AL2 DIA. AL3 DIA. FC2 DIA. PC81 10 AD2,5 1,5 mm 3,0 mm 3,0 mm 2,0 mm 3,0 mm 2 mm poles Part numbers 0116 951.15 0116 796.12 0196 796.13 0176 817.13 0163 070.00 0163 261.00 0007 865.26 0173 523.11 0114 205.20 2 5 6 7 R R See section on markers marking method 11 Note : (1) End sections and circuit separators snapped on rails.  ZZZHQWUHOHFUX   Fuse holder terminal blocks Double-deck M 4/8.D2.SF M 4/8.D2.SF... Spacing 8 mm (.315") Spacing 8 mm (.315") Standard block. M 4/8.D2.SF with blown fuse indicator. Grey body. for 5 x 20 and 5 x 25 mm fuses Compression clamp DIN 1 - DIN 3 BAMH 0114 836.00 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Part numbers Color Type Grey Beige V0 M 4/8.D2.SF M 4/8.D2.SF.V0 0115 604.21 0195 604.22 M 4/8.D2.SFL M 4/8.D2.SFD M 4/8.D2.SFD1 Characteristics Characteristics Wire size Wire size Compression Solid wire clamp Stranded wire Accessories 3 4 2 3 5 6 7 8 5 24-12 AWG 24-12 AWG 630 V (7) 8 kV 3 300 V (1) 250 V 6,3 A 10 A 10 A IEC NFC DIN UL CSA 0,5-4 mm² 0,5-4 mm² 24-12 AWG 24-12 AWG 24-12 AWG 24-12 AWG 500 V (7) 6 kV 3 300 V (1) 250 V 6,3 A 10 A 10 A Compression Solid wire clamp Stranded wire Rated Pulse Pollution degree Rated Wire size 12 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 9,5 mm .37" 4 mm .16" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 9,5 mm .37" 4 mm .16" 0,5-0,8 Nm 4.4-7 Ib.in IP 20 ANT 250 V FU520 Fuse 5 x 25 mm 250 V FU525 Fast acting HPC 1500 A 12 11 Disconnect link bar 12 Shield connector 0115 646.22 0115 647.23 0115 648.04 Current Rated / Gauge 8, 9 11 24-12 AWG 24-12 AWG Wire size grey FEM8D2S FEM8D2S AL2 (1) Test socket AL3 (1) AL4 (1) FC2 (3) Test plug FC4 (4) BJM8 (1) Assembled BJM8 (1) jumper bar BJM8 (1) (without IP 20 protection) BJM8 (1) BJM8 (1) EL6 Connector plate PC81 Comb-type jumper bar AD2,5 IDC jumper TGA8 Assembly rod 9 Assembly ring 10 Fuse 5 x 20 mm 10 0,5-4 mm² 0,5-4 mm² Current 6 7 CSA 4 mm² / A4 12 AWG Type 2 4 UL Part numbers Voltage Rated Pulse Pollution degree 1 End section 1 IEC NFC DIN Voltage Rated * Blocks with LED indicator are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required. Neon lamp110-230 V (5) LED 24 V (6) LED 48 V (6) CN5 CBD2S 4 mm² / A4 12 AWG Part numbers Type (V2) (V0) DIA. DIA. DIA. DIA. DIA. 41 A 41 A 41 A 41 A 41 A 35 A 35 A 24 A 2 mm 3 mm 4 mm 2 mm 4 mm 10 poles 2 poles 3 poles 4 poles 0,5 1 2 3,15 5 1,6 2 2,5 4 6,3 A A A A A A A A A A 0116 913.07 0196 913.00 0163 043.21 0163 261.00 0163 262.01 0007 865.26 0167 860.01 0168 520.05 0168 521.22 0168 522.23 0168 523.24 0168 974.00 0173 627.21 0173 523.11 0114 205.20 0168 672.11 0168 673.12 0168 674.13 0168 675.14 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0168 804.07 0178 408.14 Part numbers FEM8D2S AL2 (1) AL3 (1) AL4 (1) FC2 (3) FC4 (4) BJM8 (1) BJM8 (1) BJM8 (1) BJM8 (1) BJM8 (1) EL6 PC81 AD2,5 TGA8 12 AWG 0116 913.07 DIA. DIA. DIA. DIA. DIA. 41 A 41 A 41 A 41 A 41 A 35 A 35 A 24 A ANT FU520 FU525 CBD2S 2 mm 3 mm 4 mm 2 mm 4 mm 10 poles 2 poles 3 poles 4 poles 0,5 1 2 3,15 5 1,6 2 2,5 4 6,3 A A A A A A A A A A 0163 043.21 0163 261.00 0163 262.01 0007 865.26 0167 860.01 0168 520.05 0168 521.22 0168 522.23 0168 523.24 0168 974.00 0173 627.21 0173 523.11 0114 205.20 0168 672.11 0168 673.12 0168 674.13 0168 675.14 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0178 408.14 R R See section on markers 17 RC 810 on side marking method 6 RC 610 on grip 6 RC 610 on grip 17 RC 810 on side Note : (1) Only for lower deck. (2) Only for upper connection. Use of these accessories requires the user to cut out the partition. (3) For block equipped with test socket AL2. (4) For block equipped with test socket AL4. (5) Leakage current with neon lamp : < 0,5 mA (110 VAC), < 0,7 mA (230 VAC). (6) Leakage current with LED 24 or 48 VDC < 4,5 mA. (7) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating.  ZZZHQWUHOHFUX   Fuse holder terminal blocks Double-deck M 4/8.D2.SF... M 4/8.D2 Spacing 8 mm (.315") Spacing 8 mm (.315") M 4/8.D2.SF with* or without blown fuse indicator. Internal jumpering option. Grey body. Terminal block compatible with fuse block M 4/8.D2.SF for 5 x 20 and 5 x 25 mm fuses Compression clamp DIN 1 - DIN 3 With or without blown fuse indicator. Note: For terminal block with matching profile to fuse block M 4/8.D2.SF, use M 4/8.D2 shown here. Color Type Part numbers Color M 4/8.D2.SFJ Grey Blocks with blown fuse indicator : M 4/8.D2.SFLJ Neon lamp 110-220 V* (5) M 4/8.D2.SFDJ LED 24 V* (6) M 4/8.D2.SFDJ1 LED 48 V* (6) Type Part numbers 0115 692.11 Grey 0115 649.05 0115 650.02 0115 651.27 All characteristics are equal to the M 4/8.D2.SF Characteristics M 4/8.D2 0360 004.05 Characteristics Wire size BAMH 0114 836.00 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Compression Solid wire clamp Stranded wire Rated Pulse Pollution degree Rated / Gauge Wire stripping length 24-12 AWG 24-12 AWG 500 V (7) 6 kV 3 300 V (7) 250 V 6,3 A 10 A 10 A 4 mm² / A4 12 AWG 4 mm .157" 0,5-0,8 Nm 4.4-7 Ib.in 4 2 3 5 6 7 grey FEM8D2S AL2 (1) AL3 (1) AL4 (1) FC2 (3) Test plug FC4 (4) BJM8 (1) Assembled BJM8 (1) jumper bar BJM8 (1) (without IP 20 protection) BJM8 (1) BJM8 (1) EL6 Connector plate PC81 Comb-type jumper bar TGA8 Assembly rod 41 A 41 A 41 A 41 A 41 A 35 A 35 A 5 8 Assembly ring 9 Fuse 5 x 20 mm UL CSA ANT 250 V FU520 7, 8 Fuse 5 x 25 mm 250 V FU525 Fast acting HPC 1500 A 10 13 Screw for BJS CN5 CBD2S BJS8 (2) EV6 VJS11 (2) DIA. DIA. DIA. DIA. DIA. 2 mm 3 mm 4 mm 2 mm 4 mm 10 2 3 4 poles poles poles poles 0,5 1 2 3,15 5 1,6 2 2,5 4 6,3 6 10 Disconnect link bar 11 Shield connector 12 Jumper bar not assembled 12 AWG Protection Wire stripping length Recommended Recommended screwdriver torque 41 A A A A A A A A A A A 20 poles Protection IP 20 Part numbers Type Type 3 12, 13 24-12 AWG 24-12 AWG Recommended Recommended screwdriver torque 1 End section 2 Test socket 11 0,5-4 mm² 0,5-4 mm² IEC NFC DIN Wire size Accessories 9 CSA Current 9,5 mm .374" 4 UL Voltage Rated * Blocks with LED indicator are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required. 1 IEC NFC DIN Part numbers 0116 913.07 0163 043.21 0163 261.00 0163 262.01 0007 865.26 0167 860.01 0168 520.05 0168 521.22 0168 522.23 0168 523.24 0168 974.00 0173 627.21 0173 523.11 0168 672.11 0168 673.12 0168 674.13 0168 675.14 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0168 804.07 0178 408.14 0174 789.05 0168 604.16 0163 394.26 R R See markers section method Note : 6 RC 610 on lever 17 RC 810 on side (1) These accessories can be used on the lower connection only. (2) These accessories can be used on the upper connection only. Use of these accessories requires the user to cut out the partition. (3) For block equipped with test socket AL2. (4) For block equipped with test socket AL4. (5) Leakage current with neon lamp: < 0,5 mA (110 VAC), < 0,7 mA (230 VAC). (6) Leakage current with LED 24 or 48 VDC : < 4,5 mA. (7) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating.  ZZZHQWUHOHFUX   MB 10/12.SF... Fuse holder terminal block with screwed plug Spacing 12 mm (.473") for 5 x 20 mm or 5 x 25 mm fuses Compression clamp DIN 1 - DIN 3 12 mm block, no blown fuse indicator - for 5 x 20 mm or 5 x 25 mm fuses Color Type Grey/5x20 mm Grey/5x25 mm MB 10/12.SF MB 10/12.SF1 Part numbers 0111 033.03 0111 035.05 Characteristics BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 18-6 AWG 18-6 AWG 18-6 AWG 18-6 AWG 500 V Gr.C (1) 600 V (1) 250 V 10 A 15 A 15 A Voltage Rated Pulse Pollution degree Current Rated Wire size Rated / Gauge Accessories 1 6 AWG 6 AWG Recomm. screwdriver Recomm. torque Protection 13 mm .512" 6 mm .236" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 10 Type 1 End section 2 Standard jumper bar 3 IDC jumper 4 Fuse 5 x 20 mm 2 10 mm² Wire stripping length Part numbers V2 grey FEM12S 57 A BJS12 (2) Screw for BJS Washer for BJS AD2,5 250 V FU520 3 Fuse 5 x 25 mm 250 V FU525 Fast acting HPC 1500 A 4 th. 3 mm 20 poles 0,5 1 2 3,15 5 1,6 2 2,5 4 6,3 A A A A A A A A A A 0117 628.22 0177 653.07 0163 574.22 0163 633.25 0114 205.20 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 R R See section on markers marking method 6 Sides of block Note : (1) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating. (2) Use of these accessories requires the user to cut out the partition.  ZZZHQWUHOHFUX   MB 10/12.SF... Fuse holder terminal block with screwed plug MB 10/12.SFD1 Spacing 12 mm (.473") Spacing 12 mm (.473") 12 mm block with neon blown fuse indicator for fuses 5 x 20 mm. 12 mm block without foot, with neon fusion indicator for fuses 5 x 20 mm. for 5 x 20 mm fuses Compression clamp DIN 1 - DIN 3 BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Grey/110-220V (2) Grey/LED 24 V (3) MB 10/12.SFL MB 10/12.SFD Part numbers Colour 0111 034.04 0111 037.07 Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 18-6 AWG 18-6 AWG 18-6 AWG 18-6 AWG 500 V Gr.C (1) 600 V (1) 10 A 15 A Voltage 250(SFL) 24(SFD) Rated Pulse Pollution degree Current CSA 0,5-16 mm² 0,5-10 mm² 18-6 AWG 18-6 AWG 18-6 AWG 18-6 AWG 500 V Gr.C (1) 600 V (1) 24 V 15 A 10 A 15 A 15 A Rated Wire size 6 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 13 mm .512" 6 mm .236" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 10 13 mm .512" 6 mm .236" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 10 10 mm² 6 AWG grey FEM12S AD2,5 250 V FU520 10 mm² 6 AWG Part numbers Type Type V2 24 A 2 4 Removable locking foot , Rails UL Current Rated / Gauge 1 End section 2 IDC jumper 3 Fuse 5 x 20 mm DIN th. 3 mm 0,5 1 2 3,15 5 A A A A A 0117 628.22 0114 205.20 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 FEM12S AD2,5 FU520 th. 3 mm 0,5 1 2 3,15 5 A A A A A 3 4 R 6 Sides of block 6 AWG Part numbers V2 24 A ACD13.10 grey R See section on markers marking method 0111 038.10 Voltage Rated Pulse Pollution degree Wire size 1 NFC Compression Solid wire clamp Stranded wire Part numbers MB 10/12.SFD1 Characteristics Rated Accessories Type Grey/LED 24 V (3) 6 Sides of block Note : (1) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating. (2) Max. leakage current : 1,8 mA (3) Max. leakage current : 5,2 mA  ZZZHQWUHOHFUX   0117 628.22 0114 205.20 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0118 683.23 MU 10/13.SF1 Fuse holder terminal blocks for 5 x 20 mm and 5 x 25 mm fuses Compression clamp MU 10/14,5.SF1 Spacing 13 mm (.512") Spacing 14,5 mm (.571") 13 mm block for blown fuse indicator (to be ordered separately). 14,5 mm block for blown fuse indicator (to be ordered separately). DIN 1 - DIN 3 Color Type Part numbers Color Black V0 MU 10/13.SF1 0199 012.17 Characteristics BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. 750 V Gr.C (1) 600 V (1) 600 V (1) 16 A 16 A 16 A Voltage Current 3 Test socket 3 4, 5, 6 7 8 9 4 5 6 7 Standard jumper bar Screw for BJ Washer for BJ Fuse 5 x 20 NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. Rated Pulse Pollution degree 750 V Gr.C (1) 600 V (1) 600 V (1) 16 A 16 A 16 A Current Rated Wire size 6 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 10 mm² 10 AWG Type 2 black FEM13U FC2 FC4 AL2 AL3 AL4 BJS131 VJS11 RDJ11 250 V FU520 10 mm² 10 AWG Part numbers Type V0 th. DIA. DIA. DIA. DIA. DIA. 10 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles 0,5 A 1 A 2 A 3,15 A 5 A Fuse 5 x 25 250 V FU525 1,6 A Fast acting HPC 1500 A 2 A 2,5 A 4 A 6,3 A 8 Blown fuse indicator LEN Neon 110 - 230 VAC Neon 480 VAC Leakage current with neon indicator < 0,5 mA (110 & 480 VAC) < 0,7 mA (230 VAC) 9 Comb-type jumper bar 70 A PC 13 10 poles 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0167 075.25 0103 909.00 FC2 FC4 AL2 AL3 AL4 11 17 Sides of block 26 Part numbers FU520 0,5 A 1 A 2 A 3,15 A 5 A FU525 1,6 A 2 A 2,5 A 4 A 6,3 A LEN Neon 110 - 230 VAC 480 VAC Neon Leakage current with neon indicator < 0,5 mA (110 & 480 VAC) < 0,7 mA (230 VAC) 0173 510.20 11 6 AWG closed block delivered with plate 0007 865.26 DIA. 2 mm 0167 860.01 DIA. 4 mm 0163 043.21 DIA. 2 mm 0163 261.00 DIA. 3 mm 0163 262.01 DIA. 4 mm R R See section on markers marking method 0199 011.16 Voltage Rated Pulse Pollution degree Rated / Gauge 1 End section 2 Test plug MU 10/14,5.SF1 Wire size NFC Wire size 1 Black V0 Part numbers Characteristics Wire size Rated Accessories Type 17 Sides of block 26 Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating.  ZZZHQWUHOHFUX   0008 288.15 0008 290.13 0008 291.00 0008 289.16 0008 292.01 0167 546.22 0167 547.23 0167 548.04 0167 549.05 0167 550.02 0167 075.25 0103 909.00 MU 10/13.SF2 Fuse holder terminal blocks for 6,35 x 25,4 mm 1/4 x 1 in. and 6,35 x 32 mm 1/4 x 1 1/4 in. fuses Compression clamp MU 10/14,5.SF2 Spacing 13 mm (.512") Spacing 14,5 mm (.571") 13 mm block for blown fuse indicator (to be ordered separately). 14,5 mm block for blown fuse indicator (to be ordered separately). DIN 1 - DIN 3 BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Part numbers Color Black V0 MU 10/13.SF2 0199 014.11 Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. 750 V Gr.C (1) 600 V (1) 600 V (1) 16 A 16 A 16 A Voltage Current 3 4, 5, 6, 8 8 Blown fuse indicator 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. Rated Pulse Pollution degree 750 V Gr.C (1) 600 V (1) 600 V (1) Rated 16 A 16 A 16 A 10 mm² 10 AWG Rated / Gauge Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 10 mm² 10 AWG Part numbers Type V0 th. DIA. DIA. DIA. DIA. DIA. 10 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 110 - 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles x 32 A A A A A A A A A LEN 230 VAC Neon 480 VAC Neon Leakage current with neon indicator < 0,5 mA (110 & 480 VAC) < 0,7 mA (230 VAC) 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 Part numbers delivered with the block DIA. 2 mm DIA. 4 mm DIA. 2 mm DIA. 3 mm DIA. 4 mm FC2 FC4 AL2 AL3 AL4 FU633 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 0167 075.25 0103 909.00 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 110 - x 32 A A A A A A A A A LEN 230 VAC Neon 480 VAC Neon Leakage current with neon indicator < 0,5 mA (110 & 480 VAC) < 0,7 mA (230 VAC) R R See section on markers marking method 6 AWG 6 AWG Recomm. screwdriver black FEM13U FC2 FC4 AL2 Test socket AL3 AL4 BJS131 Standard jumper bar VJS11 Screw for BJ RDJ11 Washer for BJ FU633 Fuse 6,35 x 32 mm Quick blow fuse cartridge as per UTE 93435 7 CSA Wire size Type 4 5 6 7 UL Wire stripping length 1 End section 2 Test plug 2 Compression Solid wire clamp Stranded wire DIN Current Rated / Gauge 3 NFC 0199 013.10 Voltage Rated Pulse Pollution degree Wire size 1 Part numbers MU 10/14,5.SF2 Black V0 Characteristics Rated Accessories Type 11 17 Sides of block 26 11 17 Sides of block 26 Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating.  ZZZHQWUHOHFUX   0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 0167 075.25 0103 909.00 Switch terminal blocks with neutral cartridge MU 10/13.SN3 MU 10/14,5.SN3 Spacing 13 mm (.512") Spacing 14,5 mm (.570") 13 mm block with neutral cartridge locked on blue holder. 14,5 mm block with neutral cartridge locked on blue holder. Compression clamp DIN 1 - DIN 3 End stop th. 9,1 mm BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 Other end stops : See Accessories section Rail PR30 prepunched 0173 220.05 35 x 7,5 x 1 Rail 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Black/Blue V0 MU 10/13.SN3 Part numbers Color 0199 021.10 Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. 750 V Gr.C 600 V 600 V 16 A 6A 16 A Voltage Current 2 3 4, 5, 6 UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 6 AWG max. 6 AWG max. Rated Pulse Pollution degree 750 V Gr.C 600 V 600 V 16 A 6A 16 A Rated Wire size 6 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 12 mm .47" 5,5 mm .22" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 20 NEMA 1 10 mm² 10 AWG Type 1 End section 2 Test plug 4 5 6 7 8 Compression Solid wire clamp Stranded wire DIN Current Rated / Gauge 3 NFC 10 mm² V0 th. DIA. DIA. DIA. DIA. DIA. 10 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles 10 poles 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0173 510.20 0173 582.15 FC2 FC4 AL2 AL3 AL4 CN R 26 11 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0173 582.15 8 17 Sides of block 6 AWG Part numbers delivered with the block DIA. 2 mm DIA. 4 mm DIA. 2 mm DIA. 3 mm DIA. 4 mm 7 11 10 AWG Part numbers Type black FEM13U FC2 FC4 Test socket AL2 AL3 AL4 Standard jumper bar 57 A BJS131 Screw for BJS VJS11 Washer for BJS RDJ11 Comb-type jumper bar 70 A PC13 Neutral cartridge CN R See section on markers marking method 0199 015.12 Voltage Rated Pulse Pollution degree Wire size 1 Part numbers MU 10/14,5.SN3 Characteristics Rated Accessories Type Black/Blue V0 17 Sides of block  ZZZHQWUHOHFUX   26 ML 10/13.SF Fuse holder terminal blocks for 6,35 x 25,4 mm 1/4 x 1 in. and 6,35 x 32 mm 1/4 x 1 1/4 in. fuses Compression clamp ML 10/13.SN Spacing 13 mm (.512") Spacing 13 mm (.512") DIN 1 - DIN 3 13 mm block with disconnect link bar locked on blue lever. 13 mm standard block. BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Black V0 ML 10/13.SF Part numbers Color 0199 095.13 Characteristics Wire size Wire size Compression Solid wire clamp Stranded wire IEC NFC DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 22-8 AWG 22-8 AWG 800 V (1) 8 kV 3 600 V (1) 600 V (1) 16 A 25 A 25 A Voltage Current 2 7 8 5 10 mm² / A6 10 AWG Wire stripping length Recomm. screwdriver Recomm. torque 12 mm .472" 5,5 mm .217" 1,2-1,4 Nm 10.6-12.3 Ib.in Type 5 6 3 4 UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 22-8 AWG 22-8 AWG 800 V 8 kV 3 600 V 600 V 16 A 25 A 25 A Rated Pulse Pollution degree Rated Wire size 1 End section 2 Test plug 4 IEC NFC DIN Current Rated / Gauge 3 Compression Solid wire clamp Stranded wire 0199 105.22 Voltage Rated Pulse Pollution degree Wire size 1 Part numbers ML 10/13.SN Characteristics Rated Accessories Type Black / Blue V0 black FEM13U V0 FC2 FC4 Test socket AL2 AL3 AL4 Standard jumper bar BJS131 (2) screw for BJS VJS11 washer for BJS RDJ11 Comb-type jumper bar 70 A PC13 Assembly rod TGA13 TGA13 TGA13 Assembly ring ANT Fuse 6,35x32 mm (1/4 x 1 1/4") FU633 BPC quick-blow fuse cartridge as per IEC 127-2 6-7 8 HPC time delay fuse cartridge as per UL 198G 8 AWG Rated / Gauge Protection Wire stripping length Recomm. screwdriver Recomm. torque 12 mm .472" 5,5 mm .217" 1,2-1,4 Nm 10.6-12.3 Ib.in 10 mm² / A6 10 AWG Part numbers Type th. DIA. DIA. DIA. DIA. DIA. 10 10 2 3 4 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles poles poles poles poles x 32 A A A A A A A A A 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0173 510.20 0168 564.05 0168 565.06 0168 566.07 0168 675.14 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 8 AWG Protection Part numbers FEM13U V0 FC2 FC4 AL2 AL3 AL4 BJS131 (2) VJS11 RDJ11 PC13 TGA13 TGA13 TGA13 ANT th. DIA. DIA. DIA. DIA. DIA. 10 10 2 3 4 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles poles poles poles poles 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0173 510.20 0168 564.05 0168 565.06 0168 566.07 0168 675.14 Installation of jumper bar not assembled R R See section on markers marking method 6 RC610 on top of block 17 RC810 on sides of bock 26 6 RC610 on top of block 17 RC810 on sides of block Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating. (2) Use of these accessories require the user to cut out the partition.  ZZZHQWUHOHFUX   26 ML 10/13.SFL... Fuse holder terminal blocks for 6,35 x 25,4 mm 1/4 x 1 in. and 6,35 x 32 mm 1/4 x 1 1/4 in. fuses Compression clamp ML 10/13.SFD... Spacing 13 mm (.512") Spacing 13 mm (.512") 13 mm block with neon blown fuse indicator. 13 mm block with LED blown fuse indicator. DIN 1 - DIN 3 End stop th. 9,1 mm BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 Other end stops : See Accessories section Rail PR30 prepunched 0173 220.05 35 x 7,5 x 1 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Black V0/110-230V Black V0/480V ML 10/13.SFL ML 10/13.SFL1 Accessories 1 2 Characteristics Compression Solid wire clamp Stranded wire 3 4 5 6 7 8 5 IEC NFC DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 22-8 AWG 22-8 AWG 800 V (1) 8 kV 3 600 V (1) 600 V (1) 16 A 25 A 25 A Voltage Part numbers ML 10/13.SFD ML 10/13.SFD1 Wire size Compression Solid wire clamp Stranded wire 0199 166.26 0199 167.27 IEC NFC DIN UL CSA 0,5-16 mm² 0,5-10 mm² 22-10 AWG 22-10 AWG 22-8 AWG 22-8 AWG 800 V (1) 8 kV 3 600 V (1) 600 V (1) 16 A 25 A 25 A Voltage Rated Pulse Pollution degree Current Rated Pulse Pollution degree Current Wire size Rated Wire size Rated / Gauge 10 mm² / A6 Recomm. screwdriver Recomm. torque 12 mm .472" 5,5 mm .217" 1,2-1,4 Nm 10.6-12.3 Ib.in black FEM13U V0 FC2 FC4 AL2 Test socket AL3 AL4 BJS131 (2) Standard jumper bar VJS11 screw for BJS RDJ11 washer for BJS Comb-type jumper bar 70 A PC13 TGA13 Assembly rod TGA13 TGA13 ANT Assembly ring FU633 Fuse 6,35x32 mm (1/4 x 1 1/4") BPC quick-blow fuse cartridge as per IEC 127-2 6-7 8 HPC time delay fuse cartridge as per UL 198G Leakage current with neon indicator 8 AWG Rated / Gauge Protection Wire stripping length Recomm. screwdriver Recomm. torque 12 mm .472" 5,5 mm .217" 1,2-1,4 Nm 10.6-12.3 Ib.in 10 AWG Wire stripping length Type 4 Type Black V0/LED 24V Black V0/LED 48V Wire size 1 End section 2 Test plug 3 0199 168.00 0199 165.25 Characteristics Rated * Blocks with LED indicator are labeled "+" on the outside of the lever. The indicator can be reversed in the field if required. Part numbers Color 10 mm² / A6 10 AWG Part numbers Type th. DIA. DIA. DIA. DIA. DIA. 10 10 2 3 4 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles poles poles poles poles x 32 A A A A A A A A A 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0173 510.20 0168 564.05 0168 565.06 0168 566.07 0168 675.14 FEM13U V0 FC2 FC4 AL2 AL3 AL4 BJS131 (2) VJS11 RDJ11 PC13 TGA13 TGA13 TGA13 ANT FU633 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 < 0,5 mA (110 & 480 V) < 0,7 mA (230 V) 8 AWG Protection Part numbers th. DIA. DIA. DIA. DIA. DIA. 10 10 2 3 4 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 1,5 mm 2 mm 4 mm 2 mm 3 mm 4 mm poles poles poles poles poles x 32 A A A A A A A A A 0199 635.24 0007 865.26 0167 860.01 0163 043.21 0163 261.00 0163 262.01 0175 991.11 0163 394.26 0168 783.01 0173 510.20 0168 564.05 0168 565.06 0168 566.07 0168 675.14 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 Leakage current with LED indicator 24 V or 48 V < 4,5 mA R R See section on markers marking method 6 RC610 on top of block 17 RC810 on sides of block 26 6 RC610 on top of block 17 RC810 on sides of block Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating. (2) Use of these accessories requires the user to cut out the partition.  ZZZHQWUHOHFUX   26 M 10/16.SF... Fuse holder terminal blocks for 6,35 x 32 mm 1/4 x 1 1/4 in. fuses Compression clamp M 10/16.SN Spacing 16 mm (.630") Spacing 16 mm (.630") 16 mm block with or without blown fuse indicator. 16 mm block with disconnect link bar locked on blue holder. DIN 1 - DIN 3 Color BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Part numbers Color Type Grey Characteristics Characteristics NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-10 mm² 0,5-6 mm² 24-8 AWG 24-8 AWG 24-8 AWG 24-8 AWG 750 V Gr.C (1) 600 V (1) 600 V (1) Rated Pulse Pollution degree 16 A 16 A 16 A 6 mm² 8 AWG Wire stripping length Recomm. screwdriver Recomm. torque 11 mm .433" 5,5 mm .217" 0,8-1 Nm 7.1-8.9 Ib.in FU633 70 A 70 A 70 A 70 A 3 Insulating tip 4 Blown fuse indicator (2) UL CSA 0,5-10 mm² 0,5-6 mm² 24-8 AWG 24-8 AWG 24-8 AWG 24-8 AWG Rated Pulse Pollution degree 750 V Gr.C (1) 600 V 600 V 16 A 16 A 16 A Rated 8 AWG Rated / Gauge Protection Wire stripping length Recomm. screwdriver Recomm. torque 11 mm .433" 5,5 mm .217" 0,8-1 Nm 7.1-8.9 Ib.in 6 mm² 8 AWG Part numbers Type Type 2 Comb-type jumper bar Compression Solid wire clamp Stranded wire DIN Wire size 2, 3 4 NFC Current Current Rated / Gauge 1 0115 379.06 Voltage Voltage Wire size 1 Fuse 6,35 x 32 mm quick-blow fuse 250 V Part numbers M 10/16.SN Wire size Wire size Rated Accessories Type Without blown fuse indicator : Grey M 10/16.SF 0115 377.24 For fusion indicator to be ordered separately : Grey M 10/16.SFL 0115 378.05 PC16 PC16 PC16 PC16 EIP LEN (2) Neon LEN (2) Neon Leakage current with neon indicator 6,35 0,25 0,63 1 1,6 2,5 4 6,3 10 16 2 3 4 10 x 32 A A A A A A A A A poles poles poles poles 0168 554.03 0168 555.04 0168 556.05 0168 557.06 0168 558.17 0168 559.10 0168 560.15 0168 561.02 0168 562.03 0116 729.26 0116 733.12 0116 734.13 0116 735.14 0113 550.24 110 - 230 V AC 0167 075.25 480 V AC 0103 909.00 < 0,5 mA (110 & 480 V) < 0,7 mA (230 V AC) LED 24 VDC Max. leakage current = 5.2mA 8 AWG Protection Part numbers PC16 PC16 PC16 PC16 EIP 2 3 4 10 poles poles poles poles 0116 729.26 0116 733.12 0116 734.13 0116 735.14 0113 550.24 0175 423.17 GANGED POLYPHASE FUSE DISCONNECT Hinged lever and pop-up carrier fuse holders are available in ganged polyphase 2, 3 and 4 pole assemblies, with up to 32 A fuses. Use for convenient manual isolating of switches. R R See section on markers marking method 11 17 Sides of block 26 11 17 Sides of block 26 Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating. (2) Only for block P/N : 0115 378.05  ZZZHQWUHOHFUX   M 10/16.SF1 Fuse holder terminal blocks for 8,5 x 31,5 mm 11/32 x 1 1/4 in. fuses Compression clamp M 10/16.SN1 Spacing 16 mm (.630") Spacing 16 mm (.630") 16 mm block without blown fuse indicator. 16 mm block with disconnect link bar locked on blue holder. DIN 1 - DIN 3 BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Color Type Grey M 10/16.SF1 Part numbers Color 0115 375.22 Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-10 mm² 0,5-6 mm² 24-8 AWG 24-8 AWG 24-8 AWG 24-8 AWG 750 V Gr.C (1) 600 V 600 V (1) 20 A 16 A 20 A Voltage Current 2, 3 6 mm² 8 AWG Wire stripping length Recomm. screwdriver Recomm. torque 11 mm .433" 5,5 mm .217" 0,8-1 Nm 7.1-8.9 Ib.in 3 Insulating tip CSA 0,5-10 mm² 0,5-6 mm² 24-8 AWG 24-8 AWG 24-8 AWG 24-8 AWG Rated Pulse Pollution degree 750 V Gr.C (1) 600 V 600 V (1) 20 A 16 A 20 A Rated 8 AWG Rated / Gauge Protection Wire stripping length Recomm. screwdriver Recomm. torque 11 mm .433" 5,5 mm .217" 0,8-1 Nm 7.1-8.9 Ib.in 6 mm² 8 AWG Part numbers Type FU853 70 A 70 A 70 A 70 A UL Wire size Type 2 Comb-type jumper bar Compression Solid wire clamp Stranded wire DIN Current Rated / Gauge 1 Fuse 8,5 x 31,5 mm NFC 2 4 6 10 16 20 2 3 4 10 PC16 PC16 PC16 PC16 EIP A A A A A A poles poles poles poles 0163 847.24 0163 848.05 0163 849.06 0163 850.03 0163 851.20 0163 852.21 0116 729.26 0116 733.12 0116 734.13 0116 735.14 0113 550.24 11 17 Sides of block 26 PC16 PC16 PC16 PC16 EIP 11 8 AWG Protection Part numbers 2 3 4 10 poles poles poles poles R R See section on markers marking method 0115 376.23 Voltage Rated Pulse Pollution degree Wire size 1 Part numbers M 10/16.SN1 Characteristics Rated Accessories Type Grey / Blue 17 Sides of block 26 Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating.  ZZZHQWUHOHFUX   0116 729.26 0116 733.12 0116 734.13 0116 735.14 0113 550.24 Modular fuse-holder FE8.1 for 8,5 x 31,5 mm 11/32 x 1 1/4 in. fuses FE8.1N.C FE8-10.N Spacing 17,6 mm (0.69") 1 module Spacing 17,6 mm (0.69") 1 module FE8.1N Spacing 17,6 mm (0.69") 1 module Spacing 35,2 mm (1.39") 2 modules DIN 3 3.1" Pending — please consult us IP20 protection Standards : IEC 947-3 / 269-2 Rail Rail Rail The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched 0164 800.03 0168 500.12 0101 598.26 1 pole 1 pole Reference Type P/N Standard With blown-fuse indicator With blown-fuse indicator FE8.1 FE8.1 FE8.1 8711 568.01 FE8-10.N 8711 568.11 8711 568.12 24-48 AC/DC / 48-115 VAC 115-690 VAC Type P/N 2 poles : 1 phase + neutral 2 poles : 1 phase + neutral Type Type P/N P/N 8711 627.01 FE8.1N.C 8721 568.01 FE8.1N 8715 568.01 FE8.1N.C 8721 568.12 FE8.1N 8715 568.12 Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size Solid wire Stranded wire Gauge 2 mm AWG Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG 3 IEC multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 4 8,5 x 31,5 mm fuses (see accessories, page 154) 5 Flat pin terminal 15 mm (25 mm²) 30 mm UL CSA IEC UL CSA IEC UL 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 0.5-10 0.5-6 A4 0.5-16 0.5-10 A5 400 20 6 mm2 690 32 6 mm2 400 20 6 mm2 400 20 6 mm2 Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 2 CSA 12 mm / .47" 1.2 Nm / 10.6 Ib.in Accessories 1 UL P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 BTVP15 BTVP30 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 P/N 0399 0206 RAU8970 RAU8970 RAU8970 FU853 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 4 5 R R see section on markers RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   CSA RC55 - RC510 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 RAU8970 460.01 RAU8970 460.02 FE8.3 FE8.2 Spacing 35,2 mm (1.39") 2 modules FE8.3N.C Spacing 52,2 mm (2.08") 3 modules FE8.4 FE8.3N Spacing 52,2 mm (2.08") 3 modules Spacing 70.4 mm (2.77") 4 modules Spacing 70,4 mm (2.77") 4 modules Pending — please consult us The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 3 poles 2 poles Type P/N Type FE8.2 8712 568.01 FE8.3 P/N 4 poles : 3 phases + neutral 4 poles : 3 phases + neutral 4 poles Type Type Type P/N 8713 568.01 FE8.3N.C P/N 8726 568.13 FE8.3N FE8.3N IEC UL CSA IEC UL CSA IEC UL CSA IEC P/N 8714 568.01 8716 568.01 FE8.4 8716 568.12 UL CSA IEC UL 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 0.5-10 0.5-6 A4 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 400 20 6 mm2 400 20 6 mm2 400 20 6 mm2 400 20 6 mm2 400 20 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type P/N Type 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 BTVP15 BTVP30 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 RC55 - RC510 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 FT1 125.24 KE8-10 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FU853 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 RC55 - RC510 RC55 - RC510 P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 0399 371.13 FT1 0206 125.24 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 RC55 - RC510 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 CSA Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU853 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 RAU8970 460.01 RAU8970 460.02 RC55 - RC510  ZZZHQWUHOHFUX   Modular fuse-holder FE10.1 for 10,3 x 38 mm 13/32 x 1 1/2 in. fuses FE10.1N.C FE8-10.N Spacing 17,6 mm (0.69") 1 module Spacing 17,6 mm (0.69") 1 module Spacing 17,6 mm (0.69") 1 module FE10.1N Spacing 35,2 mm (1.39") 2 modules DIN 3 3.1" Pending — please consult us IP20 protection Standards : IEC 947-3 / 269-2 The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 1 pole 1 pole Reference Type P/N Standard With blown-fuse indicator With blown-fuse indicator FE10.1 FE10.1 FE10.1 8711 628.01 FE8-10.N 8711 628.11 8711 628.12 24-48 AC/DC / 48-115 VAC 115-690 VAC Type P/N 2 poles : 1 phase + neutral 2 poles : 1 phase + neutral Type Type P/N P/N 8711 627.01 FE10.1N.C 8721 628.01 FE10.1N 8715 628.01 FE10.1N.C 8721 628.12 FE10.1N 8715 628.12 Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 2 3 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 690 32 6 mm2 multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 4 10,3 x 38 mm fuses (see accessories, page 154) 5 Flat pin terminal 15 mm (25 mm²) 30 mm 600 30 6 AWG 600 30 6 AWG IEC P/N UL IEC UL CSA IEC UL 0.5-10 0.5-6 A4 0.5-16 0.5-10 A5 690 32 6 mm2 690 32 6 mm2 690 32 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 CSA 0.5-16 0.5-10 A5 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 1 UL CSA pending pending FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 BTVP15 BTVP30 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 P/N 0399 0206 RAU8970 RAU8970 RAU8970 FU103 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 4 5 R R see section on markers RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   CSA RC55 - RC510 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 RAU8970 460.01 RAU8970 460.02 FE10.3 FE10.2 Spacing 35,2 mm (1.39") 2 modules FE10.3N.C Spacing 52,2 mm (2.08") 3 modules Spacing 52,2 mm (2.08") 3 modules FE10.4 FE10.3N Spacing 70.4 mm (2.77") 4 modules Spacing 70,4 mm (2.77") 4 modules Pending — please consult us The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 3 poles 2 poles Type P/N Type P/N FE10.2 8712 628.01 FE10.3 4 poles : 3 phases + neutral 4 poles : 3 phases + neutral 4 poles Type Type Type P/N 8713 628.01 FE10.3N.C P/N 8726 628.01 FE10.3N FE10.3N IEC UL CSA pending pending 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 690 32 6 mm2 600 30 6 AWG 600 30 6 AWG IEC 0.5-16 0.5-10 A5 P/N 600 30 6 AWG Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 600 30 6 AWG IEC P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 BTVP15 BTVP30 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL IEC UL CSA IEC UL CSA pending pending 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 690 32 6 mm2 690 32 6 mm2 690 32 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 FT1 125.24 KE8-10 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FU103 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 RC55 - RC510 CSA 8716 628.12 0.5-10 0.5-6 A4 12 mm / .47" 1.2 Nm / 10.6 Ib.in FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 RC55 - RC510 20-6 AWG 20-6 AWG 690 32 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type UL CSA pending pending P/N RC55 - RC510 P/N Type 0399 371.13 FT1 0206 125.24 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 RC55 - RC510 8724 628.01 8716 628.01 FE10.4 600 30 6 AWG 600 30 6 AWG 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 20-6 AWG 20-6 AWG Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 FU103 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 RAU8970 460.01 RAU8970 460.02 RC55 - RC510  ZZZHQWUHOHFUX   Assembly kit Pending — please consult us Fuses 0,6 A 1 A 2 A 4 A 6 A 8 A 10 A 12 A 16 A 20 A 25 A 32 A KE8-10 0206 125.24 The kit is composed of 10 packages of these 4 parts. 2 pole assembly Distribution (gG) Motor protection (aM) consult us consult us 0167 076.26 0167 077.27 0167 078.00 0167 079.01 0167 080.27 0167 081.14 0167 082.15 0167 083.16 0167 084.17 0167 085.10 0167 086 11 0167 087.12 0167 088.23 0167 089.24 0167 090.21 0167 091.16 0167 092.17 consult us 0167 094.11 0167 095.12 consult us consult us Current 2 4 6 10 16 20 Part number A A A A A A 0167 086 11 0167 087.12 0167 076.26 0167 077.27 0167 078.00 0167 079.01 Pending — please consult us Plate mounting FT1 FU853 - 8,5 x 31,5 mm FU103 - 10,3 x 38 mm - 500 V Current 0399 371.13 Screw (M4) not delivered Holes Ø 4,2 or Ø M 4 Pending — please consult us Jumper bar With spade With flat pin isolated spade 10 mm2 isolated flat pin 10 mm2 Number of poles Number of modules Dimensions (mm) Type Part number Number of poles Number of modules Dimensions (mm) Type Part number 1 1 1 2 2 3 3 4 4 12 13 57 12 60 12 60 12 60 210 225 1000 210 1065 210 1065 210 1065 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 RAU8970 452.12 RAU8970 452.13 RAU8970 452.57 RAU8970 453.12 RAU8970 453.60 RAU8970 454.12 RAU8970 454.60 RAU8970 455.12 RAU8970 455.60 1 1 2 2 3 3 4 4 12 57 12 60 12 60 12 60 210 1000 210 1065 210 1065 210 1065 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 RAU8970 456.12 RAU8970 456.57 RAU8970 457.12 RAU8970 457.60 RAU8970 458.12 RAU8970 458.60 RAU8970 459.12 RAU8970 459.60 Pending — please consult us Terminal block for 25 mm² wire With spade Model Dimensions (mm) Type Part number with flat pin 15 30 15 30 BTVP 15 BTVP 30* BTVF 15 BTVF 30* RAU8970 460.01 RAU8970 460.02 RAU8970 461.01 RAU8970 461.02 with spade With flat pin * to be used with jumper bars  ZZZHQWUHOHFUX   MB 10/22.SF... Fuse-holder terminal blocks for 10,3 x 38 mm 13/32 x 1 1/2 in. fuses Compression clamp MB 10/22.SN Spacing 22 mm (.866") Spacing 22 mm (.866") DIN 1 - DIN 3 22 mm block with disconnect link bar locked on blue holder. 22 mm block with or without blown fuse indicator. Color Type Part numbers Color Without blown fuse indicator : MB 10/22.SF 0116 302.23 Grey With blown fuse indicator to be ordered separately : MB 10/22.SFL 0116 303.24 Grey BADL V0 0199 408.02 th. 9,1 mm End stop BAM 0103 002.26 th. 9,1 mm End stop Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Characteristics Wire size Wire size Compression Solid wire Stranded wire clamp IEC NFC DIN UL CSA 0,5-10 mm² 0,5-6 mm² 18-6 AWG 18-10 AWG 18-6 AWG 18-10 AWG 800 V (1) 600 V (1) 600 V (1) 30 A 55 A 55 A Rated Pulse Pollution degree 4 UL CSA 0,5-10 mm² 0,5-6 mm² 18-6 AWG 18-10 AWG 18-6 AWG 18-10 AWG 800 V (1) 600 V 600 V 30 A 55 A 55 A Rated Pulse Pollution degree Rated Wire size 6 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 12,5 mm .492" 6,5 mm .256" 2.3-4 Nm 20-35 Ib.in IP 10 12,5 mm .492" 6,5 mm .256" 2.3-4 Nm 20-35 Ib.in IP 10 6 mm² 6 AWG 6 mm² 6 AWG Part numbers Type Type 70 A PC22 PC22 AD2,5 2 IDC jumper FU103 3 Fuse 10,3 x 38 mm - 500 V 0,6 A 1 A 2 A 4 A 6 A 8 A 10 A 12 A 16 A 20 A 25 A 32 A LEN (2) 4 Blown Fuse indicator (2) LEN (2) 1 Comb-type jumper bar 3 IEC NFC DIN Current Current Rated / Gauge 2 Compression Solid wire Stranded wire clamp 0116 304.25 Voltage Voltage Wire size 1 Part numbers MB 10/22.SN Characteristics Rated Accessories Type Grey / Blue 3 poles 10 poles STD 0205 295.06 0174 151.25 0114 205.20 Slow blow 0167 086.11 0167 087.12 0167 088.23 0167 089.24 0167 090.21 0167 091.16 0167 092.17 PC22 PC22 AD2,5 6 AWG Part numbers 3 poles 10 poles 0205 295.06 0174 151.25 0114 205.20 0167 076.26 0167 077.27 0167 078.00 0167 079.01 0167 080.27 0167 081.14 0167 082.15 0167 094.11 0167 083.16 0167 095.12 0167 084.17 0167 085.10 110 - 230 V 0167 075.25 Neon 480 V AC 0103 909.00 Neon < 0,5 mA (110 & 480 V AC) Leakage current with neon indicator < 0,7 mA (230 V AC) LED 24VDC 0175 423.17 R max. leakage current 5.2ma R See section on markers marking method 6 on top of the block 6 on top of the block Note : (1) Insulation voltage of terminal block - operating voltage : in accordance with fuse rating. (2) Only for P/N : 0116 303.24 Disconnect assemblies MB 10/22.S1N MB 10/22.S2 MB 10/22.S2N MB 10/22.S3 MB 10/22.S3N MB 10/22.S4  ZZZHQWUHOHFUX   1 pole + neutral 2 poles 2 poles + neutral 3 poles 3 poles + neutral 4 poles 0116 287.14 0116 290.23 0116 269.01 0116 293.12 0116 272.24 0116 296.15 Fuse holder terminal blocks with screwed plugs MB 10/24.SF... MB 25/30.SF Spacing 24 mm (.950") Spacing 30 mm (1.180") 24 mm closed thermoset block for 10,3 x 38 and DO1 fuses. 30 mm closed block for DO2 fuses. for 10,3 x 38 mm 13/32 x 1 1/2 in. and DO1 - DO2 fuses Compression clamp DIN 1 - DIN 3 Color Type Part numbers Color Grey / white plug for 10,3 x 38 13/32 x 1 1/2 fuses MB 10/24.SF 0116 299.20 Grey / black plug for DO1 fuses MB 10/24.SF1 0116 298.27 End stop th. 9,1 mm BADL V0 0199 408.02 End stop th. 9,1 mm BAM 0103 002.26 Other end stops : See Accessories section Rail 35 x 7,5 x 1 PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Characteristics Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-16 mm² 0,5-10 mm² 18-8 AWG 18-8 AWG 18-6 AWG 18-6 AWG 750 Gr.C (1) 600 V 600 V 32 A 35 A 30 A Voltage Current 3 Fuse DO1 380 V UL Compression Solid wire 0,75-25 mm² clamp Stranded wire 0,75-25 mm² Rated Pulse Pollution degree 750 Gr.C (1) Rated 63 A 6 AWG Rated / Gauge Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 13 mm .51" 6 mm .236" 1,2-1,4 Nm 10.6-12.3 Ib.in IP 10 10 mm .394" 8 mm .315" 2-2,5 Nm 17.4-21.7 Ib.in IP 10 BJS24 AD2,5 500 V FU103 0,5 A 1 A 2 A 4 A 6 A 8 A 10 A 12 A 16 A 20 A 25 A 32 A FUD1 2 A 4 A 6 A 10 A 16 A Fuse DO2 380 V 10 mm² 8 AWG 25 mm² Part numbers Type 30 A 24 A 10 poles STD 0167 076.26 0167 077.27 0167 078.00 0167 079.01 0167 080.27 0167 081.14 0167 082.15 0167 083.16 0167 084.17 0167 085.10 DO1 0167 848.01 0167 849.02 0167 850.07 0167 851.24 0167 852.25 pink brown green red 0167 856.21 0114 205.20 Slow.Blow 0167 086.11 0167 087.12 0167 088.23 0167 089.24 0167 090.21 0167 091.16 0167 092.17 0167 093.10 0167 094.11 0167 095.12 BJS24 AD2,5 Part numbers 30 A 24 A 10 poles FUD2 20 A 25 A 35 A 50 A 63 A 6 Sides of block 0167 856.21 0114 205.20 Gauge 0167 844.25 0167 845.26 0167 846.27 0167 847.20 DO2 0174 072.21 0174 073.22 0174 074.23 0174 075.24 0174 076.25 blue yellow black white R R See section on markers marking method CSA Wire stripping length Type 2 DIN Wire size Rated / Gauge 1 NFC 0116 305.26 Current Wire size 1 Standard jumper bar 2 IDC jumper 3 Fuse 10,3 x 38 mm Part numbers Voltage Rated Pulse Pollution degree Rated Accessories Type Grey / black plug for DO2 fuses MB 25/30.SF 17 Sides of block 26 Note : (1) Insulation voltage of terminal block - operating voltage : In accordance with fuse rating.  ZZZHQWUHOHFUX   Gauge 0174 094.10 0174 095.11 0174 104.27 0174 105.20 Modular fuse-holder FE14.2... FE14.1... for 14 x 51 mm 9/16 x 2 in. fuses Spacing 26,5 mm (1.04") 1.5 modules FE14.3... Spacing 53 mm (2.08") 3 modules Spacing 79,5 mm (3.12") 4.5 modules DIN 3 microswitch (1) Influence of voltage on I max. current Voltage I max. 690 V 400 V 25 A 50 A Influence of number of poles on I max. current Two position clip for rail mounting IP 20 protection 1 pole 2 poles ** 1 microswitch controlling 3 poles Standards : IEC 269-2-1, IEC 947-3 35 x 7.5 x 1 PR30 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 Rail Rail Rail prepunched prepunched 0164 800.03 0168 500.12 0101 598.26 Reference Microswitch description (see page 160) Indicator : 120 V min. 690 V max. Type Standard With indicator (microswitch in accessory) With microswitch P/N FE14.1 FE14.1.I FE14.1.M IEC Characteristics Wire size Type P/N RFS1001.13 FE14.2 RFS1001.46 RFS1001.18 FE14.2.M* UL CSA IEC Type RFS1001.16 RFS1001.19 FE14.3.M** RFS1001.20 CSA In 0,80 x In 0,70 x In 0,60 x In Temp. I max. 20°C 30°C 40°C 50°C In 0.95 x In 0.90 x In 0,80 x In P/N RFS1001.15 FE14.3 UL I max. 1-2-3 4-5-6 7-8-9 > 10 Influence of ambient temperature on I max. current 3 poles * 1 microswitch controlling 2 poles No. of poles IEC UL Solid wire 1.5-35 1.5-35 1.5-35 Stranded wire 1.5-35 1.5-35 1.5-35 V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 690 (1) 50 (1) 35 mm2 690 (1) 50 (1) 35 mm2 690 (1) 50 (1) 35 mm2 CSA 2 mm AWG Voltage max. (1) Current max. (1) Rated wire size Wire stripping length Recommended torque 12 mm / .47" 3 Nm / 26.4 lb.in. Modular fuse-holder 12 mm / .47" 3 Nm / 26.4 lb.in. FE14.1N... FE14.N for 14 x 51 mm 9/16 x 2 in. fuses 12 mm / .47" 3 Nm / 26.4 lb.in. Spacing 26,5 mm (1.04") 1.5 modules Spacing 53 mm (2.08") 3 modules FE14.3N... Spacing 79,5 mm (3.12") 4.5 modules DIN 3 microswitch (1) Influence of voltage on I max. current Voltage I max. 690 V 400 V 25 A 50 A Influence of number of poles on I max. current Two position clip for rail mounting IP 20 protection 1 neutral + 1 pole 1 neutral Standards : IEC 269-2-1, IEC 947-3 35 x 7.5 x 1 PR30 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched prepunched 0164 800.03 0168 500.12 0101 598.26 Reference Microswitch description (see page 160) Indicator : 120 V min. 690 V max. Standard With indicator With microswitch Wire size P/N P/N FE14.N RFS1001.31 FE14.1N FE14.1N.M IEC Characteristics Type Type UL CSA IEC Type P/N RFS1001.14 FE14.3N RFS1001.17 RFS1001.39 FE14.3N.M* RFS1001.40 UL CSA IEC UL Solid wire 1.5-35 1.5-35 1.5-35 Stranded wire 1.5-35 1.5-35 1.5-35 V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 690 (1) 50 (1) 35 mm2 690 (1) 50 (1) 35 mm2 690 (1) 50 (1) 35 mm2 CSA 2 mm AWG Voltage max. (1) Current max. (1) Rated wire size Wire stripping length Recommended torque 12 mm / .47" 3 Nm / 26.4 lb.in. 12 mm / .47" 3 Nm / 26.4 lb.in. I max. 1-2-3 4-5-6 7-8-9 > 10 In 0,80 x In 0,70 x In 0,60 x In Influence of ambient temperature on I max. current 1 neutral + 3 poles * 1 microswitch controlling 3 poles Rail Rail Rail No. of poles 12 mm / .47" 3 Nm / 26.4 lb.in.  ZZZHQWUHOHFUX   Temp. I max. 20°C 30°C 40°C 50°C In 0.95 x In 0.90 x In 0,80 x In FJ21.1... Modular fuse-holder for 21 x 57 mm 13/16 x 2 1/4 in. fuses DIN 3 Class J - Assembly kit FJ21.3... FJ21.2... Spacing 32,5 mm (1.28") Spacing 65 mm (2.56") Spacing 97,5 mm (3.84") KJ21 RFS1001.33 Two position clip for rail mounting IP 20 protection 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 prepunched 35 x 15 x 1.5 PR5 Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 Reference Indicator : 90 VAC - 115 VDC min. 600 VAC/DC max. Standard With indicator P/N FJ21.1 FJ21.1.I RFS1001.01 FJ21.2 RFS1001.04 FJ21.2.I CSA UL Solid wire 2.5-50 Stranded wire 2.5-50 14-0 AWG 14-0 AWG RFS1001.02 FJ21.3 RFS1001.05 FJ21.3.I CSA UL IEC 2.5-50 2.5-50 P/N Type P/N Type Type IEC Characteristics Wire size 3 poles 2 poles 1 pole Standard : UL listed, file No E196143 14-0 AWG 14-0 AWG RFS1001.03 RFS1001.06 CSA UL IEC 2.5-50 2.5-50 14-0 AWG 14-0 AWG 2 mm AWG AC ~/= DC V A mm² / AWG mm / inches Nm / Ib.in Voltage Current Rated wire size Wire stripping length Recommended torque 13 mm / .51" 4 Nm / 35.2 lb.in. Modular fuse-holder FJ27.1... for 27 x 60 mm 1 1/16 x 2 3/8 in. fuses DIN 3 Class J - 13 mm / .51" 4 Nm / 35.2 lb.in. FJ27.3... FJ27.2... Spacing 40 mm (1.57") 600 30 0 AWG 600 30 0 AWG 600 600 30 30 0 AWG 0 AWG 13 mm / .51" 4 Nm / 35.2 lb.in. 600 30 0 AWG 600 30 0 AWG Spacing 80 mm (3.15") Assembly kit Spacing 120 mm (4.72") KJ27 Two position clip for rail mounting IP 20 protection 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 prepunched 35 x 15 x 1.5 PR5 Rail Rail Rail 2.5-50 Stranded wire 2.5-50 CSA 14-0 AWG 14-0 AWG UL IEC 2.5-50 2.5-50 RFS1001.09 RFS1001.12 RFS1001.08 FJ27.3 RFS1001.11 FJ27.3.I RFS1001.07 FJ27.2 RFS1001.10 FJ27.2.I UL IEC Solid wire P/N Type P/N Type P/N Type FJ27.1 FJ27.1.I Standard With indicator Characteristics Wire size 3 poles 0164 800.03 0168 500.12 0101 598.26 Reference Indicator : 90 VAC - 115 VDC min. 600 VAC/DC max. 2 poles 1 pole Standard : UL listed, file No E196143 CSA 14-0 AWG 14-0 AWG UL IEC 2.5-50 2.5-50 CSA 14-0 AWG 14-0 AWG 2 mm AWG Voltage Current Rated wire size Wire stripping length Recommended torque AC ~/= DC V A mm² / AWG mm / inches Nm / Ib.in 600 600 60 60 0 AWG 0 AWG 13 mm / .51" 5.2 Nm / 45.8 lb.in. 600 60 0 AWG 600 60 0 AWG 13 mm / .51" 5.2 Nm / 45.8 lb.in. 600 60 0 AWG 600 60 0 AWG 13 mm / .51" 5.2 Nm / 45.8 lb.in.  ZZZHQWUHOHFUX   RFS1001.36 FE22.2... FE22.1... Modular fuse-holder for 22 x 58 mm 7/8 x 2 1/4 in. fuses Spacing 35 mm (1.38") 2 modules FE22.3... Spacing 70 mm (2.76") 4 modules Spacing 105 mm (4.13") 6 modules DIN 3 microswitch (1) Influence of voltage on I max. current Voltage I max. 690 V 400 V 80 A 125 A Influence of number of poles on I max. current Two position clip for rail mounting IP 20 protection 1 pole 2 poles ** 1 microswitch controlling 3 poles Standards : IEC 269-2-1, IEC 947-3 35 x 7.5 x 1 PR30 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 Rail Rail Rail prepunched prepunched 0164 800.03 0168 500.12 0101 598.26 Reference Microswitch description (see page 160) Indicator : 120 V min. 690 V max. Type Standard With indicator (microswitch in accessory) With microswitch P/N FE22.1 FE22.1.I FE22.1.M IEC Characteristics Wire size RFS1001.21 RFS1001.58 RFS1001.26 UL CSA Type P/N FE22.2 RFS1001.23 FE22.3 RFS1001.24 FE22.2.M* RFS1001.27 FE22.3.M** RFS1001.28 IEC UL Type CSA I max. 1-2-3 4-5-6 7-8-9 > 10 In 0,80 x In 0,70 x In 0,60 x In Influence of ambient temperature on I max. current 3 poles * 1 microswitch controlling 2 poles No. of poles Temp. I max. 20°C 30°C 40°C 50°C In 0.95 x In 0.90 x In 0,80 x In P/N IEC UL Solid wire 1.5-50 1.5-50 1.5-50 Stranded wire 1.5-50 1.5-50 1.5-50 690 (1) 125 (1) 50 mm2 690 (1) 125 (1) 50 mm2 690 (1) 125 (1) 50 mm2 CSA 2 mm AWG Voltage max. (1) Current max. (1) Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 16 mm / .63" 4 Nm / 35.2 lb.in. 16 mm / .63" 4 Nm / 35.2 lb.in. FE22.1N... FE22.N Modular fuse-holder for 22 x 58 mm 7/8 x 2 1/4 in. fuses 16 mm / .63" 4 Nm / 35.2 lb.in. Spacing 35 mm (1.38") 2 modules Spacing 70 mm (2.76") 4 modules FE22.3N... Spacing 140 mm (4.13") 8 modules DIN 3 microswitch (1) Influence of voltage on I max. current Voltage I max. 690 V 400 V 80 A 125 A Influence of number of poles on I max. current Two position clip for rail mounting IP 20 protection 1 neutral 1 neutral + 1 pole Standards : IEC 269-2-1, IEC 947-3 35 x 7.5 x 1 PR30 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched prepunched 0164 800.03 0168 500.12 0101 598.26 Reference Microswitch description (see page 160) Indicator : 120 V min. 690 V max. Standard With indicator With microswitch Wire size Type P/N Type P/N FE22.N RFS1001.32 FE22.1N RFS1001.22 FE22.3N RFS1001.25 FE22.1N.M RFS1001.51 FE22.3N.M* RFS1001.52 IEC Characteristics UL CSA IEC UL Type CSA P/N IEC UL Solid wire 1.5-50 1.5-50 1.5-50 Stranded wire 1.5-50 1.5-50 1.5-50 690 (1) 125 (1) 50 mm2 690 (1) 125 (1) 50 mm2 690 (1) 125 (1) 50 mm2 CSA mm2 AWG Voltage max. (1) Current max. (1) Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 16 mm / .63" 4 Nm / 35.2 lb.in. 16 mm / .63" 4 Nm / 35.2 lb.in. I max. 1-2-3 4-5-6 7-8-9 > 10 In 0,80 x In 0,70 x In 0,60 x In Influence of ambient temperature on I max. current 1 neutral + 3 poles * 1 microswitch controlling 3 poles Rail Rail Rail No. of poles 16 mm / .63" 4 Nm / 35.2 lb.in.  ZZZHQWUHOHFUX   Temp. I max. 20°C 30°C 40°C 50°C In 0.95 x In 0.90 x In 0,80 x In Accessories for FE14 and FE22 Microswitches The microswitch must be preassembled in the fuse holder assembly (FE14.1.I or FE22.1.I). The assembly indicates fuse presence or fuse status. (Fuse with striking pin). The microswitch is equipped with a red mechanical indicator. Application example 1 output microswitch 3 poles TGA14-22 Microswitch enlargement pin For FE14.1... and FE22.1... Mechanical indicator FE14.1.I or FE22.1.I TGA 14-22 Assembly FE14.1.M or FE22.1.M or FE14.1.I + MFE14 or FE22.1.I + MFE22 3 independent output microswitches MFE14 MFE22 FE14.1.I or FE22.1.I RFS1001.67 RFS1001.68 Microswitch characteristics Interrupt rating (1) AC12 AC13 AC14 DC12/13/14 DC12/13 AC13 AC14/DC13 DC14 Disassembly Voltage Rated current 10 VAC/DC min. 250 V 250 V 250 V 250 V 2 V - 24 V 2 V - 24 V 2 V - 24 V 2 V - 24 V 100 mA min. 6A 3A 3A 0.1 A 6A 5A 3A 0.6 A FE14.1.M or FE22.1.M or FE14.1.I + MFE14 or FE22.1.I + MFE22 (1) According to IEC 947-5 standard Assembly kit KE14-22 Fuse-holder lock installation RFS1001.65 The kit is composed of 10 packages of these 4 parts.  ZZZHQWUHOHFUX   RFS1001.66 Modular fuse-holder FECC.1 for CC fuses FECC.3 FECC.2 Spacing 35,2 mm (1.39") 2 modules Spacing 17,6 mm (0.69") 1 module FECC.4 Spacing 52,2 mm (2.08") 3 modules Spacing 70,4 mm (2.77") 4 modules DIN 3 3.1" Pending — please consult us IP20 protection Standards : IEC 947-3 / 269-2 The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 Rail Rail Rail prepunched prepunched 0164 800.03 0168 500.12 0101 598.26 2 poles 1 pole Reference Type Standard With blown-fuse indicator With blown-fuse indicator FECC.1 FECC.1 FECC.1 24-48 AC/DC / 48-115 VAC 115-690 VAC P/N 8711 618.02 8711 618.21 8711 618.22 4 poles 3 poles Type P/N FECC.2 Type 8712 618.02 P/N FECC.3 Type 8713 618.02 P/N FECC.4 8714 618.02 Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 2 4 Flat pin terminal (25 mm²) 3 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 6 mm2 multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 15 mm 30 mm 600 30 6 AWG 600 30 6 AWG IEC FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 BTVP15 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 1 UL CSA pending pending 600 30 6 AWG FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 BTVP15 BTVP30 20-6 AWG 20-6 AWG 6 mm2 600 30 6 AWG 600 30 6 AWG IEC Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 460.01 460.02 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 BTVP15 BTVP30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 0.5-16 0.5-10 A5 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 460.01 460.02 600 30 6 AWG IEC FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 BTVP15 BTVP30 4 R R See section on markers RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   600 30 6 AWG 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 460.01 460.02 600 30 6 AWG RC55 - RC510 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 460.01 460.02 Modular fuse-holder FE...1N.C1 FE...1N.C... Spacing 17,6 mm (0.69") 1 module for domestic fuses Spacing 17,6 mm (0.69") 1 module DIN 3 3.1" Pending — please consult us IP20 protection Standards : IEC 947-3 / 269-2 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 Reference For 8,5 x 23 fuse For 10,3 x 25,8 fuse For 8,5 x 31,5 fuse For 10,3 x 31,5 fuse For 10,3 x 38 fuse Size 10 A Size 16 A Size 20 A Size 25 A Size 32 A mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 1 2 2 poles : 1 phase + neutral Type P/N Type P/N FE8.1N.C1 FE10.1N.C1 8721 468.01 8721 528.01 FE8.1N.C FE10.1N.C2 FE10.1N.C 8721 568.01 8721 588.01 8721 628.01 IEC Characteristics Wire size 2 poles : 1 phase + neutral UL CSA IEC UL 0.5-10 0.5-6 A4 0.5-10 0.5-6 A4 250 400 6 mm2 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type CSA P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit multipolar 3 Flat pin jumper bar unipolar 63 A unipolar isolated IP20 unipolar (see accessories, page 154) 4 Flat pin terminal 15 mm (25 mm²) 30 mm FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 0399 0206 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 BTVP15 BTVP30 RAU8970 460.01 BTVP15 RAU8970 460.02 BTVP30 R See section on markers RC55 - RC510 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 P/N 0399 0206 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 RAU8970 460.01 RAU8970 460.02 3 4 R RC55 - RC510  ZZZHQWUHOHFUX   Dual connection fuse-holder FB8.1 FB8.1N FB8-10.N Spacing 17,6 mm (0.69") 1 module Spacing 17,6 mm (0.69") 1 module FB8.2 Spacing 35,2 mm (1.39") 2 modules Spacing 35,2 mm (1.39") 2 modules for 8,5 x 31,5 mm 11/32 x 1 1/4 in. fuses Pending — please consult us 3.1" DIN 3 IP20 protection Standards : IEC 947-3 / 269-2 The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 1 pole : neutral 1 pole Reference Type P/N Standard With blown-fuse indicator With blown-fuse indicator FB8.1 FB8.1 FB8.1 8711 568.05 FB8-10.N 8711 568.51 8711 568.52 24-48 AC/DC / 48-115 VAC 115-690 VAC Type P/N 2 poles : 1 phase + neutral 2 poles Type Type P/N 8711 627.04 FB8.1N P/N 8715 568.05 FB8.2 8712 568.05 8715 568.52 FB8.1N Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 2 3 4 Spade jumper bar 63A isolated IP20 (see accessories, page 154) 4 5 multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 5 8,5 x 31,5 mm fuses (see accessories, page 154) 6 Flat pin terminal 15 mm (25 mm²) 30 mm 7 Spade terminal 15 mm (25 mm²) 30 mm 6 CSA IEC UL CSA IEC UL CSA IEC UL 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 400 20 6 mm2 690 32 6 mm2 400 20 6 mm2 400 20 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 1 UL 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N Type P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 7 R R See section on markers CSA RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   RC55 - RC510 FB8.3 FB8.3N Spacing 52,2 mm (2.08") 3 modules FB8.4 Spacing 70.4 mm (2.77") 4 modules Spacing 70.4 mm (2.77") 4 modules Pending — please consult us The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 3 poles 4 poles : 3 phases + neutral 4 poles Type Type Type P/N P/N FB8.3 8713 568.05 FB8.3N UL CSA 8714 568.05 8716 568.52 FB8.3N IEC P/N 8716 568.05 FB8.4 IEC UL CSA IEC 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 400 20 6 mm2 400 20 6 mm2 400 20 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type P/N 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type UL CSA 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N Type P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU853 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   Dual connection fuse-holder FB10.1 FB10.1N FB8-10.N Spacing 17,6 mm (0.69") 1 module Spacing 17,6 mm (0.69") 1 module FB10.2 Spacing 35,2 mm (1.39") 2 modules Spacing 35,2 mm (1.39") 2 modules for 10,3 x 38 mm 13/32 x 1 1/2 in. fuses Pending — please consult us 3.1" DIN 3 IP20 protection Standards : IEC 947-3 / 269-2 The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 1 pole 1 pole : neutral Reference Type P/N Standard With blown-fuse indicator With blown-fuse indicator FB10.1 FB10.1 FB10.1 8711 628.04 FB8-10.N 8711 628.41 8711 628.42 24-48 AC/DC / 48-115 VAC 115-690 VAC Type P/N 2 poles : 1 phase + neutral 2 poles Type Type P/N 8711 627.04 FB10.1N P/N 8715 628.04 FB10.2 8712 628.04 8715 628.42 FB10.1N Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 2 3 4 Spade jumper bar 63A isolated IP20 (see accessories, page 154) 4 5 multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 5 10,3 x 38 mm fuses (see accessories, page 154) 6 Flat pin terminal 15 mm (25 mm²) 30 mm 7 Spade terminal 15 mm (25 mm²) 30 mm 6 0.5-16 0.5-10 A5 20-6 AWG 20-6 AWG 690 32 6 mm2 300 30 6 AWG 300 30 6 AWG IEC UL CSA IEC CSA IEC UL CSA pending pending 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 690 32 6 mm2 690 32 6 mm2 690 32 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N UL 0.5-16 0.5-10 A5 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 1 UL CSA pending pending Type P/N Type P/N 20-6 AWG 20-6 AWG 300 30 6 AWG 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 7 R R See section on markers 300 30 6 AWG RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   RC55 - RC510 FB10.3 FB10.3N Spacing 52,2 mm (2.08") 3 modules FB10.4 Spacing 70.4 mm (2.77") 4 modules Spacing 70.4 mm (2.77") 4 modules Pending — please consult us The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 3 poles 4 poles : 3 phases + neutral 4 poles Type Type Type P/N P/N FB10.3 8713 628.04 FB10.3N 0.5-16 0.5-10 A5 UL CSA pending pending 20-6 AWG 20-6 AWG 690 32 6 mm2 300 30 6 AWG 300 30 6 AWG IEC Type P/N UL CSA IEC 0.5-16 0.5-10 A5 0.5-16 0.5-10 A5 690 32 6 mm2 690 32 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 8714 628.04 8716 628.42 FB10.3N IEC P/N 8716 628.04 FB10.4 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type UL CSA pending pending 20-6 AWG 20-6 AWG 300 30 6 AWG 300 30 6 AWG 12 mm / .47" 1.2 Nm / 10.6 Ib.in P/N Type P/N FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 FU103 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 BTVP15 BTVP30 BTVF15 BTVF30 RAU8970 RAU8970 RAU8970 RAU8970 460.01 460.02 461.01 461.02 RC55 - RC510 RC55 - RC510 RC55 - RC510 167  ZZZHQWUHOHFUX   Dual connection fuse-holder FBCC.1 FBCC.3 FBCC.2 Spacing 17,6 mm (0.69") 1 module Spacing 35,2 mm (1.39") 2 modules FBCC.4 Spacing 52,2 mm (2.08") 3 modules Spacing 70,4 mm 2.77" 4 modules for CC fuses Pending — please consult us 3.1" DIN 3 IP20 protection Standards : IEC 947-3 / 269-2 The assembly of more than 3 modular fuse-holders equipped with fuses could downgrade rated current. Consult us. 35 x 7.5 x 1 PR30 prepunched 35 x 15 x 2.3 PR4 35 x 15 x 1.5 PR5 prepunched Rail Rail Rail 0164 800.03 0168 500.12 0101 598.26 2 poles 1 pole Reference Type Standard With blown-fuse indicator With blown-fuse indicator FBCC.1 FBCC.1 FBCC.1 24-48 AC/DC / 48-115 VAC 115-690 VAC P/N 3 poles Type P/N 8711 618.06 FBCC.2 8711 618.61 8711 618.62 4 poles Type P/N Type P/N 8713 618.06 FBCC.4 8712 618.06 FBCC.3 8714 618.06 Blown fuse-indicator leakage current : < 0,5 mA at 24 V < 1 mA at 48 V < 2,5 mA at other voltages IEC Characteristics Wire size mm AWG Solid wire Stranded wire Gauge Rated voltage Rated current Rated wire size Wire stripping length Recommended torque V AC ~/= DC A mm² / AWG mm / inches Nm / Ib.in 2 Accessories 2 3 4 Spade jumper bar 63A isolated IP20 (see accessories page 154) 4 6 Flat pin terminal (25 mm²) 7 Spade terminal (25 mm²) 5 6 mm2 20-6 AWG 20-6 AWG 300 30 6 AWG multipolar unipolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar unipolar unipolar bipolar bipolar tripolar tripolar tetrapolar tetrapolar 15 mm 30 mm 15 mm 30 mm 300 30 6 AWG IEC 0.5-16 0.5-10 A5 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 1 Plate mounting kit 2 Assembly Kit 3 Flat pin jumper bar 63 A isolated IP20 (see accessories, page 154) 1 0.5-16 0.5-10 A5 UL CSA pending pending FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 BTVP15 BTVP30 BTVF15 BTVF30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 20-6 AWG 20-6 AWG 300 30 6 AWG 0.5-16 0.5-10 A5 6 mm2 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 BTVP15 BTVP30 BTVF15 BTVF30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 20-6 AWG 20-6 AWG 300 30 6 AWG Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 460.01 460.02 461.01 461.02 300 30 6 AWG IEC 0.5-16 0.5-10 A5 6 mm2 12 mm / .47" 1.2 Nm / 10.6 Ib.in 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 460.01 460.02 461.01 461.02 300 30 6 AWG IEC FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 BTVP15 BTVP30 BTVF15 BTVF30 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 UL CSA pending pending 20-6 AWG 20-6 AWG 300 30 6 AWG 12 mm / .47" 1.2 Nm / 10.6 Ib.in Type 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 460.01 460.02 461.01 461.02 FT1 KE8-10 PCP.1.12 PCP.1.13 PCP.1.57 PCP.2.12 PCP.2.60 PCP.3.12 PCP.3.60 PCP.4.12 PCP.4.60 PCF.1.12 PCF.1.57 PCF.2.12 PCF.2.60 PCF.3.12 PCF.3.60 PCF.4.12 PCF.4.60 BTVP15 BTVP30 BTVF15 BTVF30 6 R R See section on markers RC55 - RC510 RC55 - RC510 RC55 - RC510  ZZZHQWUHOHFUX   300 30 6 AWG RC55 - RC510 P/N 0399 0206 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 RAU8970 371.13 125.24 452.12 452.13 452.57 453.12 453.60 454.12 454.60 455.12 455.60 456.12 456.57 457.12 457.60 458.12 458.60 459.12 459.60 460.01 460.02 461.01 461.02 M 4/6.DE1 M 4/6.DE... Component holder terminal blocks Empty blocks Blocks with LED indicator Spacing 6 mm +0,05 (.238") Spacing 6 mm +0,05 (.238") Empty blocks for components (th. 5 mm max.). Internal, soldered connections, external, by compression clamp. Empty blocks for components (th. 5 mm max.). Internal, soldered connections, external, by compression clamp. Double deck blocks Compression clamp DIN 1 - 3 Color Type Part numbers Color Upper and lower circuit opened M 4/6.DE Grey M 4/6.DEN Blue BAMH 0114 836.00 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 Rail 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Other rails : See Accessories section Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. 0115 185.05 0125 185.07 Characteristics Wire size Wire size NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 500 V Gr.C 600 V 300 V 26 A 20 A 20 A Voltage Current 2 Separator end section 3 Test socket 3 2 4 Test device 5 Test plug 6 Assembled jumper bar (without IP 20 protection) 4 Assembled jumper bar (with IP 20 protection) 5 6 grey 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 35 A 32 A 7 Connector bar 8 Jumper bar not assembled Screw + post + washer 9 Comb-type jumper bar 35 A 10 IDC jumper 24 A 7 8 CSA 0,5-4 mm² 0,5-4 mm² 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG Rated Pulse Pollution degree 500 V Gr.C 600 V 300 V 26 A 20 A 20 A Rated Wire size 4 mm² / A4 12 AWG 4 mm² / A4 12 AWG Rated / Gauge Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 8,5 mm .33" 4 mm .157" 0.5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 8,5 mm .33" 4 mm .157" 0.5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 FEM6D FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 Part numbers Type (2) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) th. th. th. DIA. DIA. 1,0 mm 1,0 mm 1,0 mm 2,0 mm 3,0 mm DIA. 2 3 4 5 10 2 3 4 5 10 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles th. 0,5 mm 10 poles 0118 499.23 0128 499.25 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 Part numbers FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 (2) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) (1) th. 1,0 mm 0118 499.23 th. 1,0 mm DIA. 2,0 mm DIA. 3,0 mm 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 DIA. 2 3 4 5 10 2 3 4 5 10 th. 0,5 mm 10 poles 10 R 11 Sides of block Note : 12 Top of block 11 Sides of block 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles 9 R See section on markers marking method 12 AWG 12 AWG Wire stripping length Type 1 UL Compression Solid wire clamp Stranded wire DIN Current Rated / Gauge grey blue grey NFC 0115 177.14 Voltage Rated Pulse Pollution degree Wire size 1 End section Part numbers Lower circuit opened M 4/6.DE1 Grey Characteristics Rated Accessories Type 12 (1) Use of these accessories requires the user to cut out the partition. (2) For block equipped with AL2 or DCG. (3) These accessories can be used on the lower connection only.  ZZZHQWUHOHFUX   Top of block M 4/6.DE2 Component holder terminal block With neon lamp indicator Double deck M 4/6.DL... Spacing 6 mm + 0,05 (.238") Spacing 6 mm + 0,05 (.238") Empty blocks for components (th. 5 mm maxi.). Internal, soldered connections, external, by compression clamp. 1 connection with 4 inputs on 2 decks. Equipped with a nonprotected LED 24 V. Compression clamp DIN 1 - 3 Color Type Part numbers Color Upper circuit opened M 4/6.DE2 Grey 0115 326.11 Characteristics Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Solid wire Stranded wire DIN UL 0,5-4 mm² 0,5-4 mm² CSA 22-12 AWG 22-12 AWG Solid wire Stranded wire Voltage Rated Pulse Pollution degree 500 V Gr.C 300 V 26 A 20 A Current 3 2 4 5 6 4 Test device 5 Test plug 6 Assembled jumper bar (without IP 20 protection) grey Assembled jumper bar (with IP 20 protection) 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 35 A 32 A 7 Connector plate 8 Jumper bar not assembled Screw + post + washer 9 Comb-type jumper bar 35 A 10 IDC jumper 7 8 Compression clamp Compression clamp Solid wire Stranded wire DIN UL CSA 0,2-4 mm² 0,22-4 mm² 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 500 V Gr.C 600 V 300 V 20 A* 20 A* 20 A* Solid wire Stranded wire Rated Pulse Pollution degree Rated 12 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 8,5 mm .33" 4 mm .16" 0.5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 8,5 mm .33" 4 mm .16" 0.5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 4 mm² / A4 Type 1 NFC Wire size Rated / Gauge grey grey 0115 179.26 Current Wire size 1 End section 2 Separator end section 3 Test socket 0115 178.25 0115 522.06 Voltage Rated Accessories + on the upper circuit M 4/6.DL Grey body/red LED M 4/6.DLV Grey body/green LED + on the lower circuit M 4/6.DL1 Grey body/red LED Wire size NFC Compression clamp Compression clamp Part numbers Characteristics Wire size End stop th. 9,1 mm BAMH 0114 836.00 Other end stops : See Accessories section Rail PR30 prepunched 0173 220.05 35 x 7,5 x 1 Rail 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Type FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 4 mm² / A4 12 AWG Part numbers Type (2) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) th. th. DIA. DIA. 1,0 mm 1,0 mm 2,0 mm 3,0 mm DIA. 2 3 4 5 10 2 3 4 5 10 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles th. 0,5 mm 10 poles 0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 12 AWG Part numbers (2) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) th. th. DIA. DIA. 1,0 mm 1,0 mm 2,0 mm 3,0 mm DIA. 2 3 4 5 10 2 3 4 5 10 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles th. 0,5 mm 10 poles 0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 9 10 *Current rating is as shown when using top or bottom level of block. Current is limited to one ampere (1A) if connection is from top to the bottom of the block R R See section on markers marking method 11 Sides of block Note : 172 12 Top of block 11 Sides of block 12 Top of block (1) Use of these accessories requires the user to cut out the partition. (2) For block equipped with AL2 or DCG. (3) These accessories can be mounted on the lower deck only.  ZZZHQWUHOHFUX   M 4/6.DL2... Component holder terminal block With neon lamp indicator Double deck M 4/6.DN... Spacing 6 mm + 0,05 (.238") Spacing 6 mm +0,05 (.238") 1 connection with 4 inputs on 2 decks. Equipped with a protected LED. 1 connection with 4 inputs on 2 decks. Equipped with a neon lamp. Compression clamp DIN 1 - 3 Color Type Part numbers Color Grey 12 V = 24 V ~ Grey 24 V = 48 V ~ Grey 24 V = 48 V ~ M 4/6.DL2 M 4/6.DL3 M 4/6.DL4 0115 180.14 0115 181.01 0115 392.14 Characteristics Notes The use of some accessories may decrease the block's voltage rating. For more information, consult us. Solid wire Stranded wire DIN UL CSA 0,2-4 mm² 0,22-4 mm² 22-12 AWG 22-12 AWG 22-12 AWG 22-12 AWG 500 V Gr.C 600 V 300 V 20 A* 20 A* 20 A* Current 3 2 4 5 6 4 Test device 5 Test plug 6 Assembled jumper bar (without IP 20 protection) grey Assembled jumper bar (with IP 20 protection) 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 35 A 32 A 7 Connector plate 8 Jumper bar not assembled Screw + post + washer 9 Comb-type jumper bar 35 A 10 IDC jumper 7 8 NFC Compression Solid wire clamp Stranded wire DIN UL CSA 0,2-4 mm² 0,22-4 mm² 22-12 AWG 22-12 AWG 18-12 AWG 18-12 AWG Rated Pulse Pollution degree 500 V Gr.C 600 V 150 V 20 A* 20 A* 25 A* Current Rated Wire size 4 mm² / A4 12 AWG 4 mm² / A4 12 AWG 12 AWG 12 AWG Rated / Gauge Wire stripping length Recomm. screwdriver Recomm. torque Protection Wire stripping length Recomm. screwdriver Recomm. torque Protection 8,5 mm .33" 4 mm .16" 0.5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 8,5 mm .33" 4 mm .157" 0,5-0.6 Nm 4.4-5.3 lb.in IP20 NEMA 1 Type 1 0115 183.03 Voltage Rated Pulse Pollution degree Rated / Gauge grey grey M 4/6.DN1 Stranded wire Voltage Wire size 1 End section 2 Separator end section 3 Test socket 0115 182.02 Solid wire Rated Accessories M 4/6.DN Wire size NFC Compression clamp Compression clamp 110 V~ 127 V= Grey 230 V~ Grey Part numbers Characteristics Wire size BAMH 0114 836.00 End stop th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 Rail PR30 prepunched 0173 220.05 Rail 35 x 15 x 2,3 PR4 0168 500.12 35 x 15 x 1,5 PR5 prepunched 0101 598.26 Rail 32 x 15 PR1Z2 0163 050.04 Rail Other rails : See Accessories section Type FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 Part numbers Type (2) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) th. th. DIA. DIA. 1,0 mm 1,0 mm 2,0 mm 3,0 mm DIA. 2 3 4 5 10 2 3 4 5 10 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles th. 0,5 mm 10 poles 0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D PC61 AD2,5 Part numbers (2) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) (1)(3) th. th. DIA. DIA. 1,0 mm 1,0 mm 2,0 mm 3,0 mm DIA. 2 3 4 5 10 2 3 4 5 10 2,0 mm poles poles poles poles poles poles poles poles poles poles 10 poles th. 0,5 mm 10 poles 0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0163 311.22 0114 205.20 9 10 *Current rating is as shown when using top or bottom level of block. Current is limited to one ampere (1A) if connection is from top to the bottom of the block R R See section on markers marking method 11 Sides of block Note : 12 Top of block *Current rating is as shown when using top or bottom level of block. Current is limited to one ampere (1A) if connection is from top to the bottom of the block 11 Sides of block 12 (1) Use of these accessories requires the user to cut out the partition. (2) For block equipped with AL2 or DCG. (3) These accessories can be mounted on the lower deck only.  ZZZHQWUHOHFUX   Top of block Electronic component holder terminal blocks With diode Double deck M 4/6.DD M 4/6.DD1 M 4/6.DE1.D M 4/6.DE2.D Spacing 6 mm .238" Spacing 6 mm .238" Block equipped with two 1N 4007 diodes negative common (1000 V peak - 250 V service - 1 A). Block equipped with one 1N 4007 diode with two connections per anode and cathode (1000 V peak - 250 V service - 1 A) BAMH 0114 836.00 th. 9,1 mm Other end stops : See Accessories section 35 x 7,5 x 1 0173 220.05 PR30 PR4 35 x 15 x 2,3 0168 500.12 PR5 35 x 15 x 1,5 0101 598.26 32 x 15 x 1,5 0163 050.04 PR1Z2 Other rails : See Accessories section Other accessories : See Accessories section Type Type Characteristics NFC Typical lamp test application Compression clamp DIN 1 - 3 Compression clamp Wire size Grey body 1 negative output M 4/6.DE1.D DIN 0,5-4 mm² Stranded wire 0,5-4 mm² Rated current Rated wire size 0115 371.26 0115 327.12 UL CSA Accessories 1 2 3 End section Separator end section Test socket grey grey 4 5 6 Test device Test plug Assembled jumper bar (without IP 20 protection) grey 7 Assembled jumper bar (with IP 20 protection) 8 9 Connector plate Jumper bar not assembled Post + screw + washer Pivoting jumper bar Comb-type jumper bar IDC jumper 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 32 A 35 A 32 A 35 A 35 A Grey body • Cathode (K) of the blocking diode connected to the lower circuit M 4/6.DD M 4/6.DD1 0115 184.04 NFC DIN 22-12 AWG UL 22-12 AWG 18-12 AWG 150 V 300 V 500 V Gr.C 600 V 20 A* 20 A* 20 A* 25 A* th. 1 mm th. 1 mm DIA.2 mm DIA.3 mm DIA.2 mm 2 poles 3 poles 4 poles 5 poles 10 poles 2 poles 3 poles 4 poles 5 poles 10 poles 10 poles 10 poles CSA 0,22-4 mm² 500 V Gr.C Type FEM6D SCF6D AL2 (1) AL3 (1) DCG FC2 (3) BJM6D (1) (2) BJM6D (1) (2) BJM6D (1) (2) BJM6D (1) (2) BJM6D (1) (2) BJMI6D (1) (2) BJMI6D (1) (2) BJMI6D (1) (2) BJMI6D (1) (2) BJMI6D (1) (2) EL6 (1) (2) BJS61 (1) (2) EV6D BJP61 (1) PC61 AD2,5 Part numbers 0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0167 225.20 0163 311.22 0114 205.20 25 A* 4 mm² Wire stripping length Recomm. screwdriver 12 AWG Recomm. torque 12 AWG 8,5 mm .33" 4 mm .157" 0.5 - 0.6 Nm 4.4 -5.3 lb.in Type FEM6D SCF6D AL2 AL3 DCG FC2 BJM6D BJM6D BJM6D BJM6D BJM6D BJMI6D BJMI6D BJMI6D BJMI6D BJMI6D EL6 BJS61 EV6D BJP61 PC61 AD2,5 See section on markers marking method 11 12 11 Protection IP 20 NEMA 1 Part numbers (1) (1) (3) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) (1) (2) th. 1 mm th. 1 mm DIA.2 mm DIA.3 mm DIA.2 mm 2 poles 3 poles 4 poles 5 poles 10 poles 2 poles 3 poles 4 poles 5 poles 10 poles 10 poles (1) 10 poles * Current rating is as shown when using top or bottom level of block. Current is limited to one amp (1 A) if connection is from top to bottom of the block. R 0115 168.23 0,2-4 mm² 4 mm² 12 AWG Wire stripping Recomm. Recomm. length screwdriver torque Protection 8,5 mm 4 mm 0.5-0.6 Nm IP20 .33" .157" 4.4-5.3 lb.in NEMA 1 Other characteristics Part numbers • Cathode (K) of the blocking diode connected to the upper circuit Grey body 2 negative outputs M 4/6.DE2.D Solid wire Rated voltage 10 11 12 Part numbers 12 Note : (1) These accessories can be mounted on the lower deck only. (2) Use of these accessories requires the user to cut out the partition. (3) For block equipped with AL2 or DCG.  ZZZHQWUHOHFUX   0118 499.23 0118 495.17 0163 070.00 0163 261.00 0163 218.05 0007 865.26 0173 515.11 0173 516.12 0173 517.13 0173 519.25 0173 520.22 0179 668.20 0179 669.21 0179 670.26 0179 671.13 0179 672.14 0173 627.21 0168 485.27 0168 400.16 0167 225.20 0163 311.22 0114 205.20