Fused Iron™ Battery

   EMBED


Share

Transcript

PRODUCT DATASHEET: MG300 Fused Iron™ Battery Maximum Dimensions Width: Length: Height: Terminal Spacing: mm 108 157 360 83 (inches) (4.25) (6.19) (14.17) (3.25) General Specifications Battery Type: Chemical System: Weight (dry): Weight (with electrolyte): Nominal Cell Voltage: Nominal Cell Capacity (C/10): Nominal Cell Capacity (C/5): Terminals: Container: Vent: DI Water Top Up Frequency: Autofill System: System Operation Recommended Charging Charge Voltage Float Hold Voltage Optimum Charging Current Min. Charging Current Max. Cont. Charging Current Max. Pulsed Charging Current Equalization Charge Initiation Charge Optimum Discharge Current Max Discharge Current Battery Cycle Life @25°C Battery Cycle Life @35°C Battery Life on Float Battery Storage Life Constant current 1.65V - 1.75V 1.45V C/5 C/20 C/2 1C Not Required 150% min, 200% max. C/5 C/2 >11,000 cycles @ 80% DOD >6,000 cycles @ 80% DOD 20 yrs. 85 yrs. Rechargeable, Flooded Nickel Iron (NiFe) 8.0 kg (17.6 lbs) 10.5 kg (23.1 lbs) 1.2 Volts 330 Ah 300 Ah 1/4 - 28 Polypropylene (V0 available) Includes Flame Arrestor Up to 12 months Available Separately Environment Discharge Temperature (°C): Charge Temperature (°C): Storage Temperature (°C): Operating Humidity: Temperature Compensation Ah Efficiency (0 to 80% SOC) Ah Efficiency (80 to 100% SOC) -30 to +60 (-40 available) -30 to +60 (-40 available) -30 to +60 (-40 available) 5% to 95% non-condensing None 98% 75% Solar Compatible: Wind Compatible: Yes Yes Transportation Classification: UN2795 Class 8 Advantages Over Lead Acid Technology Parameter Advantage Energy - Deeper depth of discharge capability results in significantly more usable capacity. - More specific energy at recommended depth of discharge. - More volumetric energy density at recommended depth of discharge. Charging - Capable of higher rate charging. Life - Much longer cycle life. - Much longer shelf life. - Longer float charging life. Efficiency - Higher efficiency (energy out / energy in). Temperature - Higher maximum operating temperature. Air conditioning not required. - Higher safe storage temperature. - No air conditioning required. Environment - No lead content. No acid content. Important Notice This datasheet contains typical information specific to products manufactured at the time of its publication. ©Encell Technology - Contents herein do not constitute a warranty. PRODUCT DATASHEET www.encell.com Contact: [email protected] Encell Technology; 12887 NW Highway 441; Alachua, FL 32615 Phone: (386) 462-2643 Important Notice Data Engineering This datasheet contains typical information specific to products manufactured at the time of its publication. ©Encell Technology - Contents herein do not constitute a warranty.