Preview only show first 10 pages with watermark. For full document please download

Futureproof™ Speedwrap Cable

   EMBED


Share

Transcript

Product Specification Sheet Version 3.7 FT1P / FT1P-J Composite Cable APPLICATIONS The FT1P / FT1P-J Composite Cable consists of two (2) RG6 quad shield coax cables, two (2) CAT5e twisted pair cables and two (2) multi mode fiber optic cables. Installers can choose between speedwrapped or jacketed cable. The composite cable is used to distribute signals from the distribution panel to the rooms. FT1P SpeedWrap Cable The FT1P / FT1P-J composite cable comes on a 500’ reel. SPECIFICATIONS CAT5e Twisted Pair Cable Type Usage Conductor material Conductor O.D. Insulation material Insulation conductor O.D. Color Code Jacket material Jacket Colors Nominal jacket thickness Nominal overall O. D. Minimum bend radius Temperature rating Standards Attenuation (per 1000 ft) Freq (MHZ) .772 1.0 4.0 8.0 10.0 16.0 20.0 25.0 31.25 62.5 100. FT1P-J Jacketed Cable Four (4) unshielded 100 OHM extended distance/extended frequency twisted pair data cable Voice, 100 Mbps LAN applications 24 AWG solid bare copper .020 in., nominal Polyolefin 0.036 in., nominal Pair One White Blue / Blue Pair Two White Orange / Orange Pair Three White Green / Green Pair Four White Brown / Brown Polyvinyl chloride Blue / Yellow .018 in. .200 in. 2.25 in. -20° C to +60° C ANSI X3T9.5 TP-PMD, ATM PMD 155 Mbps, IEEE802.12, 100Base-VG, IEEE802.3, 10 Base-T, 100 Base-T4, 100 Base-X, IEEE802.5, 4/16 Mbps Token Ring, Digital Video Near End Cross Talk (N.E.X.T.) per 1000 ft Loss Freq (MHZ) dB 5.5 dB .772 64 6.3 dB 1.0 62 13.0 dB 4.0 53 18.0 dB 8.0 48 20.0 db 10.0 47 25.0 dB 16.0 44 28.0 dB 20.0 42 32.0 dB 25.0 41 36.0 dB 31.25 40 52.0 dB 62.5 35 67.0 dB 100. 32 12382 south gateway park place, 700 draper, utah 84020 801.617.3100 801.617.3194 fax www.futuresmart.com ©1996-2002 Product Specification Sheet Version 3.7 SPECIFICATIONS (CONT.) RG-6 Quad Shield Cable Type Center Conductor Center Conductor O.D. Dielectric Material Dielectric core O.D. Dielectric insulation Foil Shields Coverage Number of Braid shields Braid shield material Number of foil shields Foil shields material Jacket material Jacket thickness Overall O.D. Characteristic Impedance Capacitance Velocity of propagation Conductor DC resistance Usage RG-6/U quad shield Type 75 ohm, non plenum coaxial cable 18 AWG solid bare copper .040 in, nominal 60° C Cellular Polyethylene .0180 in., nominal 5 KV rms 100% coverage, 20% minimum overlap 2 Aluminum 2 Aluminum foil tape 60° C Polyinylchloride 0.032 in., nominal 0.280 in., nominal 75 ± 3 Ω 17.3 pF/ft, nomial 78% nominal 2.2 ohm / 100 ft Video display, point of sale terminals, local area network controls, TV/CATV and cable modems Nominal attenuation per 100 ft .4 dB @772 KHz 2.7 dB @ 200 MHz .7 dB @ 10 MHz 4.7 dB @ 500 MHz 1.5 dB @ 50 MHz 6.5 dB @ 900 MHz 2.0 dB @ 100 MHz Multi-Mode Fiber Optic Cable Type Diameter (core/cladding) Optical Type Optical material Operating Wavelength Buffer Diameter Storage temperature Operating temperature Max. tensile load for installation Max. tensile load, log term Min. bend radius for installation Min. bend radius, unloaded Crush resistance Impact resistance Flexing Attenuation @ 850 nm Bandwidth @ 850 nm Attenuation @ 1300 nm Bandwidth @ 1300 nm Single fiber cable, tight buffer, Kevlar strength member, flame retardant OFNR (riser) rated PVC outer jacket, NEC rated 62.5 / 125 microns Multi-Mode Glass 850 nm / 1300 nm 900 microns -40° to +70° C -20° to +70° C 1000 N (225 lbf) 500 N (112 lbf) 6.0 cm (2.4 in.) 3.0 cm (1.2 in.) 750 N/cm 1000 impacts 10,000 ± 90° occurrences <=3.5 dB/km >= 160 MHz*km <= 1.0 dB/km >= 500 MHz*km 12382 south gateway park place, 700 draper, utah 84020 801.617.3100 801.617.3194 fax www.futuresmart.com ©1996-2002