Preview only show first 10 pages with watermark. For full document please download

Fx1 Fire Detection Control Panel

   EMBED


Share

Transcript

Tech Data Sheet D01748GB0 36/2014 Fire Detection FX1 FIRE DETECTION CONTROL PANEL FX1 Control Panel FX1 is a powerful one loop fire detection control panel. The full range of Schneider Electric’s Intellia intelligent detectors can be connected to the system. Versatile built-in control logic enables easy control of both passive as well as active fire protective equipment and even a three-stage alert and evacuation alarm. The panel is compatible with other fire detection equipment, such as the fireman’s panel FMP2, zone led panel ZLPX, alarm delay panel DAP2, communication protocol repeater REPX and logic control unit MCOX, as well as alarm management system ESGRAF. The system also provides an interface to the building management system. Panel installation The FX1 panel is installed on a surface with the display at a height of approximately 170 cm. The wall has to be strong enough to support the weight of the panel and the batteries. Connections See overleaf for general overview of the connections of the FX1 panel. Cable entries are from behind, from above and from below. Commissioning and Configuration The system can be started after the jumper settings are verified. For customer/site specific settings and entry of alarm texts, a PC and licensed software “WinFX3Net” is used. For further information, see the FX 3NET Installation and Commissioning Guide. FX1 control panel Tech Data Sheet Fire Detection D01748GB0 2 Technical data of the FX1 panel FX1 Control panel Product code Dimensions (h*w*d) [mm] Weight (fully equipped, excl. batteries) IP Rating Operating ambient temperature Storage ambient temperature Maximum ambient humidity Back frame material Cover material Cover colour Mains supply voltage Mains supply power Operating voltage range Maximum current consumption in standby condition Maximum current consumption in alarm condition 0070 3801XX Including FX-ALCA loop controller of one loop 328 x 425 x 130 6 kg IP30 +5…+40°C 0…+50°C 95% RH sheet steel plastic bluish grey 230 VAC ±10% / 50 ... 60Hz 80 VA 21 ... 30 Vdc Applied standards Number of card slots Battery space 0.5 A @ 24 Vdc 2.2 A @ 24 Vdc EN54-2 EN54-4 1 For option boards IOC, OCA 2 pcs 12 / 12 Ah Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 02600 Espoo, Finland Document Number D01748GB0 Telephone: +358 10 446 511 Fax: +358 10 446 5103 36 2014 © 2014 Schneider Electric. All rights reserved. Schneider Electric Fire & Security Oy reserves the right to make modifications. Tech Data Sheet Fire Detection D01748GB0 3 FX1 panel external connections Serial (RS485) communication with other FX panels (2 pcs) Serial (RS485/RS232) communication with INFO/FMPX/MCOX/DAPX/REPX/ZLPX Serial (RS232) communication with printer or maintenance tool (PC) Ethernet connection, INFO communication: Future option USB connection, maintenance tool (PC) Master controller FX-MC2 Fire Alarm Router Equipment (Alarm transmitter) Fault Warning Router Equipment (Alarm transmitter) Fire Alarm Output Power supply output 24 VDC, short circuit protected, 500 mA Monitored output (Bells, sounders, beacon), 500 mA Fault in Fire Alarm Router Equipment (Alarm transmitter) Fault in Fault Warning Router Equipment (Alarm transmitter) Loop controller FX-ALCA FX-ALCA: One addressable detection circuits, with 126 addresses FX-ALCA: One power supply outputs 24 VDC, short circuit protected, 500 mA Clean contact signal inputs (4 pcs), function configurable Input/output controller FX-IOC 0…1 pcs Clean contact relay outputs (2 pcs), max 30 VDC / 1.0 A, function configurable Monitored relay outputs (4 pcs), max 500 mA each, function configurable Power supply outputs 24 VDC (2 pcs), short circuit protected, 500 mA each Output controller FX-OCA 0…1 pcs Clean contact relay outputs (16 pcs), max 30 VDC/ 1.0 A, function configurable Power supply outputs 24 VDC (2 pcs), short circuit protected, 2 A each Power supply FX-PSA 230 VAC / 50 Hz / 80 VA Battery 24 VDC (max 34 Ah) The maximum total load of the panel is 0.5 A in normal condition and 2.2 A in alarm condition. The maximum number of IOC, OCA boards is 1. Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 02600 Espoo, Finland Document Number D01748GB0 Telephone: +358 10 446 511 Fax: +358 10 446 5103 36 2014 © 2014 Schneider Electric. All rights reserved. Note! Tech Data Sheet Fire Detection D01748GB0 4 0832 Schneider Electric Fire & Security Oy P.O. Box 415, 02601 Espoo Finland 12 For FXM 0832-CPD-1084 Issue 3 DP13001 EN 54-2:1997/AC:1999/A1:2006 EN 54-4:1997/AC:1999/A1:2002/A2:2006 Options: 7.8; 7.9.1; 7.10.3; 7.11; 7.12.2; 7.13; 8.3; 8.4; 8.9; 9.5; 10 Control and indicating equipment for fire detection and fire alarm systems for buildings FXM Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 02600 Espoo, Finland Document Number D01748GB0 Telephone: +358 10 446 511 Fax: +358 10 446 5103 36 2014 © 2014 Schneider Electric. All rights reserved. Other technical data: 66571764: installation and commissioning 66571774: operation manual 66571758 (ALC): system planning (held by the manufacturer )