Preview only show first 10 pages with watermark. For full document please download

Fxvif03a-** Valve Interface Module Controlnettm Flex I/otm

   EMBED


Share

Transcript

FXVIF03A-□□ Valve interface module ControlNetTM FLEX I/OTM Current output type, digital input/output DC48V *ControlNetTM is ControlNet International’s registered trademark. *FLEX I/OTM is Rockwell Automation’s registered trademark. ITEM SPECIFICATION Analog output 4~20mA (for valve position Load resistance 0~550Ω, Transformer isolation ×1 demand output) ±0.1% FSD at 4~20mA(Load 250Ω±1%) ±100ppm/℃ Equipped with output current monitoring (read-back input) Analog input 4~20mA (for valve position Input resistance 249Ω, Transformer isolation ×1 feedback input) ±0.1% FSD at 4~20mA ±100ppm/℃ Digital inputs Opto-isolation Current sinking input with a (+) common ×8 DC48V minimum ON current 2.5mA Digital outputs Opto-isolation Sinking output with a (+)common Open collector ×4 Maximum voltage DC48V+10% Maximum load current 0.2A Selector station interface Analog output ×2 4~20mA/300Ω or 1~5V selectable Digital input ■ Outline ×6 (External power supply DC48V or DC24V) Digital output * Current output type valve interface (4~20mA, I/P converter correspondence) * Valve position demand analog output ×1 * Valve position feedback analog input ×1 ×6 (Maximum voltage DC24V+10% load current 0.1A) FPGA type identification FXVIF03A-□□ code (Module model is expressed with 2 digits of □□) Self-diagnostic functions FPGA execution abnormal Connector omission Power supply voltage low Bus time-out Read back abnormal * Universal digital input * Universal digital output * Selector station interface Analog output Digital input Digital output ×8 Indicator LED×1 Module status indication LED×16 ×4 Compatible terminal base 1794 - TB3 System status indication Dielectric strength AC500V Between analog I/O terminal and FG (1min.) AC1500V ×2 ×6 ×6 Between digital I/O terminal and FG (1min.) Environmental conditions (Operating) Temperature: 0 ~ 55 ℃ Humidity: 35 ~ 95 % RH (No condensation) * FLEX I/OTM / ControlNetTM LAN compatible (Storage) Temperature: -10 ~ 70 ℃ Humidity: Less than 80 % RH (No condensation) Power supply DC 48V±10% / Less than 100mA DC 5V±10% / Less than 80mA(FLEX BUS) Shock/Vibration 15G / 2G @ 10~500Hz Dimensions 110mmD×46mmH×94mmW This product incorporates technology which is licensed from Rockwell Automation Technologies, Inc. Rockwell Automation Technologies, Inc. has not technically approved, nor does it warrant or support this product. All warranty and support for this product and its application is provided solely by MITSUBISHI HITACHI POWER SYSTEMS, LTD. CGS-N2902-E-01 (2014.03.31) FXVIF03A-□□ Valve interface module ControlNetTM FLEX I/OTM Current output type, digital input/output DC48V *ControlNetTM is ControlNet International’s registered trademark. *FLEX I/OTM is Rockwell Automation’s registered trademark. FXVIF03A-□□ block diagram FXVIF03A 1794-TB3 DC48VP 5V DC5V/80mA 3.3V + DC/DC converter - DC48V Power supoply 1.2V LED×17 DC48VN Valve position feedback input 4~20mA A/D converter AGND_1 FLEX bus interface Valve position demand output 4~20mA AGND_2 Digital output Photo coupler ×4ch FLEX BUS FLEX BUS Digital input Photo coupler ×8ch FPGA Connector Power supply for station Selector station DC48V or DC24V Button Photo coupler ×6ch 48VGND or 24VGND DC24V Lamp Photo coupler ×6ch 24VGND Indicator AGND_3 ×2ch Please read the attached instruction manual carefully before use. Reproduction of this manual’s contents in whole or in part without permission is prohibited. Please note the product introductions in this manual may be different from the real products due to product improvements etc. CGS-N2902-E-01 (2014.03.31)