Preview only show first 10 pages with watermark. For full document please download

Fxvif04b-** Valve Interface Module Controlnettm Flex I/otm

   EMBED


Share

Transcript

FXVIF04B-□□ Valve interface module ControlNetTM FLEX I/OTM Current output type, analog input distributor type, digital input/output DC24V *ControlNetTM is ControlNet International’s registered trademark. *FLEX TM is Rockwell Automation’s registered trademark. ITEM SPECIFICATION Analog output 4~20mA (for valve position Load resistance 0~550Ω, Transformer isolation ×1 demand output) ±0.1% FSD at 4~20mA(Load 250Ω±1%) ±100ppm/℃ Equipped with output current monitoring (read-back input) Analog input 4~20mA (for valve position (Distributor type) ×1 feedback input) Input resistance 249Ω, Transformer isolation ±0.1% FSD at 4~20mA ±100ppm/℃ Digital inputs Opto-isolation Current sinking input with a (+)common ×8 DC24V minimum ON current 2.5mA Digital outputs Opto-isolation Sinking output with a (+)common Open collector ×4 Maximum voltage DC24V+10% Maximum load current 0.2A Selector station interface Analog output ×2 4~20mA/300Ω or 1~5V selectable Digital input ■ Outline ×6 (External power supply DC24V) * Current output type valve interface (4~20mA, I/P converter correspondence) * Valve position demand analog output ×1 Digital output ×6 (Maximum voltage DC24V+10% load current 0.1A) FPGA type identification FXVIF04B-□□ code (Module model is expressed with 2 digits of □□) Self-diagnostic functions * Valve position feedback analog input ×1 (distributor type) FPGA execution abnormal Connector omission Power supply voltage low Bus time-out * Universal digital input * Universal digital output * Selector station interface Analog output Digital input Digital output ×8 ×4 Read back abnormal Indicator Compatible ×2 ×6 ×6 * FLEX I/OTM / ControlNetTM LAN compatible LED×1 Module status indication LED×16 System status indication 1794 - TB3 terminal base Dielectric strength AC500V Between analog I/O terminal and FG (1min.) AC1500V Between digital I/O terminal and FG (1min.) Environmental conditions (Operating) Temperature: 0 ~ 55 ℃ Humidity: 35 ~ 95 % RH (No condensation) (Storage) Temperature: -10 ~ 70 ℃ Humidity: Less than 80 % RH (No condensation) Power supply DC 24V±10% / Less than 200mA DC 5V±10% / Less than 80mA(FLEX BUS) Shock/Vibration 15G / 2G @ 10~500Hz Dimensions 110mmD×46mmH×94mmW This product incorporates technology which is licensed from Rockwell Automation Technologies, Inc. Rockwell Automation Technologies, Inc. has not technically approved, nor does it warrant or support this product. All warranty and support for this product and its application is provided solely by MITSUBISHI HITACHI POWER SYSTEMS, LTD. CGS-N2905-E-01 (2014.03.31) FXVIF04B-□□ Valve interface module ControlNetTM FLEX I/OTM Current output type, analog input distributor type, digital input/output DC24V *ControlNetTM is ControlNet International’s registered trademark. *FLEX TM is Rockwell Automation’s registered trademark. FXVIF04B-□□ block diagram FXVIF04B 1794-TB3 DC24VP 5V DC5V/80mA 3.3V + DC/DC converter - DC24V Power supply 1.2V LED×17 DC24VN DISTP A/D converter Current Limiter Valve position feedback input 4~20mA AGND_1 FLEX bus interface Valve position demand output 4~20mA AGND_2 Digital output Photo coupler ×4ch FLEX BUS Digital input Photo coupler ×8ch FPGA Connector Power supply for station Selector station DC24V Button Photo coupler ×6ch 24VGND DC24V Lamp Photo coupler ×6ch 24VGND Indicator AGND_3 ×2ch Please read the attached instruction manual carefully before use. Reproduction of this manual’s contents in whole or in part without permission is prohibited. Please note the product introductions in this manual may be different from the real products due to product improvements etc. CGS-N2905-E-01 (2014.03.31)