Transcript
G3HT80KHB4S
Product datasheet Characteristics
Overview Description
Effective three phase power protection against downtime and data loss for mission critical applications. Ruggedized version including dust filter and conformance coated boards for harsh environments. Includes UPS and external battery cabinet for customized runtime.
Model Name
Galaxy 300 80kVA 400V 3:3 with 30min Battery (External Cabinet), Start-up 5x8
Includes
CD with software , Dust filter , Installation guide , Network Management Card , Start-Up Service , User Manual
Standard Lead Time
Usually Ships within 2 Weeks
Product Distribution
Albania , Algeria , Andorra , Angola , Argentina , Armenia , Austria , Azerbaijan , Bahrain , Belarus , Belgium , Benin , Bolivia , Bosnia And Herzegovina , Botswana , Bulgaria , Burkina Faso , Burundi , Cameroon , Central African Republic , Chad , Chile , Colombia , Congo , CONGO, THE DEMOCRATIC REPUBLIC OF THE , , Croatia , Cyprus , Czech Republic , Denmark , Djibouti , Egypt , Equatorial Guinea , Eritrea , Estonia , Ethiopia , Finland , France , Gabon , Gambia , Georgia , Germany , Ghana , Gibraltar , Greece , Guadeloupe , Guinea , French Guiana , Hungary , Iceland , Iran (Islamic Republic Of) , Iraq , Ireland , Israel , Italy , Jamaica , Jordan , Kazakhstan , Kenya , Kuwait , Latvia , Lebanon , Lesotho , Liberia , Liechtenstein , Lithuania , Luxembourg , Macedonia , Madagascar , Malawi , Mali , Malta , Martinique , Mauritania , Mauritius , Mayotte , Moldova, Republic Of , Mongolia , Morocco , Mozambique , Namibia , Netherlands , Niger , Nigeria , Norway , Oman , Pakistan , Paraguay , Peru , Poland , Portugal , Qatar , Reunion , Romania , Russian Federation , Rwanda , Saudi Arabia , Senegal , Sierra Leone , Slovakia (Slovak Republic) , Slovenia , Somalia , South Africa , Spain , Sudan , Suriname , Sweden , Switzerland , Tajikistan , TANZANIA, UNITED REPUBLIC OF , Togo , Tunisia , Turkey , Turkmenistan , Turks And Caicos Islands , Uganda , Ukraine , United Arab Emirates , Uruguay , Uzbekistan , Western Sahara , Yemen , Zambia , Zimbabwe
General Bypass Connection
5 wire (3PH + N + G)
Output Output Power Capacity
72.0 KW / 80.0 kVA
Max Configurable Power (Watts)
72.0 KW / 80.0 kVA
Nominal Output Voltage
400 3PH
Output Voltage Distortion
Less than 5%
Output Frequency (sync to mains)
50/60 Hz +/-1 Hz
Other Output Voltages
380, 415V
Crest Factor
3:1
Crest Factor
Double Conversion Online
Nov 10, 2017
1
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Galaxy 300 80kVA 400V 3:3 with 30min Battery (External Cabinet), Start-up 5x8
Output Connections
(1) Hard Wire 5-wire (3PH + N + G) (Battery Backup)
Output Voltage Tolerance
+/- 2% static and 100% load step
Output Voltage THD
Overload Operation
10 minutes @ 125% and 30 seconds @ 150%
Required Output Current Protection
160 A
Bypass
Built-in Static Bypass
Input Nominal Input Voltage
400 3PH
Input Frequency
45 - 65 Hz
Input Connections
Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations
340 - 477 V
Input voltage adjustable range for mains operation
320 - 498 (400V)V , 323 - 437 (380V)V , 340 - 460 (400V)V
Other Input Voltages
380 , 415
Maximum Input Current
122 A
Input Breaker Capacity
160 A
Maximum Short Circuit Withstand (Icw)
16.0
Input Total Harmonic Distortion
Less than 5% for full load
Type of Input Protection Required
3-pole breaker
Batteries & Runtime Battery Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
Included Battery Modules
0
Battery Slots Empty
0
Typical recharge time
0 hour(s)
RBC Quantity
0
Nominal Battery Voltage
+/-192 V (split battery referenced to neutral)
End of Discharge Battery Voltage
+/-154 V
Communications & Management Available SmartSlot™ Interface Quantity
0
Pre-Installed SmartSlot™ Cards
AP9630
Control panel
Multi-function LCD status and control console
Emergency Power Off (EPO)
Yes
Physical Maximum Height
1900.0 mm
Maximum Width
2104.0 mm
Maximum Depth
950.0 mm
Rack Height
0U
Net Weight
2085.0 kg
Shipping Weight
2145.0 kg
Shipping Height
1978.0 mm
Shipping Width
2474.0 mm
Shipping Depth
1120.0 mm
Master Carton Units
0.0
Master Carton Weight
0.0 lbs
Units per Pallet
0.0
2
Environmental Operating Environment
0 - 40 °C
Operating Relative Humidity
0 - 95% non-condensing %
Operating Elevation
0-900 meters
Storage Temperature
-15 - 40 °C
Storage Relative Humidity
0 - 95% non-condensing %
Storage Elevation
0-4500 meters
Audible noise at 1 meter from surface of unit
65.000 dB
Protection Class
IP 20
Conformance Approvals
CE , EAC , EN/IEC 62040-1 , EN/IEC 62040-2 , EN/IEC 62040-3 , ISTA 2B
Standard warranty
1 year on-site repair or replace with factory authorized Start-Up
Sustainable Offer Status RoHS
Compliant