Preview only show first 10 pages with watermark. For full document please download

G3vm-61b1

   EMBED


Share

Transcript

MOS FET Relays G3VM-61B1/E1 Analog-switching MOS FET Relay for High Switching Currents, with Dielectric Strength of 2.5 kVAC between I/O. • Upgraded G3VM-61 B/E Series. • Switches minute analog signals. • Leakage current of 1 mA max. when output relay is open. ■ Application Examples Approval pending • Measurement devices • Security systems Note: • Amusement machines The actual product is marked differently from the image shown here. ■ List of Models Contact form SPST-NO Terminals Load voltage (peak value) PCB terminals 60 VAC Model G3VM-61B1 Surface-mounting terminals Number per stick Number per tape 50 --- --- 1,500 G3VM-61E1 G3VM-61E1(TR) ■ Dimensions Note: All units are in millimeters unless otherwise indicated. G3VM-61B1 G3VM-61E1 7.12±0.25 7.12±0.25 6.4±0.25 6.4±0.25 7.62±0.25 7.62±0.25 0.8±0.25 +0.15 3.65 −0.25 +0.15 3.65 −0.25 Note: The actual product is marked differently from the image shown here. 1.2±0.15 0.5±0.1 2.54±0.25 2.5 min. 7.85 to 8.80 Weight: 0.38 g Note: The actual product is marked differently from the image shown here. 4.0 +0.25 −0.2 1.0 min. +0.1 0.25 −0.05 1.2±0.15 1.0 min. 10.0 max. 2.54±0.25 Weight: 0.38 g ■ Terminal Arrangement/Internal Connections (Top View) G3VM-61B1 6 5 4 1 2 3 ■ PCB Dimensions (Bottom View) G3VM-61B1 2.54 Six 0.8-dia. holes (0.61) G3VM-61E1 6 5 4 1 2 3 ■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61E1 2.54 2.54 2.54 8.3 to 8.8 (1.52) (0.61) (1.52) 1.3 1.5 10 G3VM-61B1/E1 G3VM-61B1/E1 ■ Absolute Maximum Ratings (Ta = 25°C) Item Input Output Symbol Rating Unit Measurement Conditions Note: LED forward current IF 50 mA Repetitive peak LED forward current IFP 1 A 100 ms pulses, 100 pps LED forward current reduction rate D IF/°C -0.5 mA/°C Ta ³ 25°C LED reverse voltage VR 5 V Connection temperature Tj 125 °C Output dielectric strength VOFF 60 V Continuous load current IO 500 mA Connection A Connection B Connection A Connection A 1,000 D ION/°C -0.5 Ta ³ 25°C mA/°C Connection B -0.5 Connection B -10.0 Connection C Tj 125 °C Dielectric strength between input and output (See note 1.) VI-O 2,500 Vrms Operating temperature Ta Connection temperature Connection Diagram 1 6 2 5 3 4 1 6 2 5 3 4 1 6 2 5 3 4 Load AC or DC 500 Connection C ON current reduction rate 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side. AC for 1 min -40 to +85 °C With no icing or condensation Storage temperature Tstg -55 to +125 °C With no icing or condensation Soldering temperature (10 s) --- 260 °C 10 s Connection C Load DC Load DC ■ Electrical Characteristics (Ta = 25°C) Item Input Symbol Minimum Typical Maximum Unit Measurement conditions Note: LED forward voltage VF 1.0 1.15 1.3 V IF = 10 mA Reverse current IR --- --- 10 mA VR = 5 V Capacity between terminals CT --- 30 --- pF V = 0, f = 1 MHz Trigger LED forward current IFT --- 1.6 3 mA IO = 500 mA Maximum resistance with output ON RON --- 1 2 W IF = 5 mA, IO = 500 mA Connection B --- 0.5 1 W IF = 5 mA, IO = 500 mA Connection C --- 0.25 --- W IF = 5 mA, IO = 1,000 mA ILEAK --- --- 1.0 mA VOFF = 60 V Capacity between I/O terminals CI-O --- 0.8 --- pF f = 1 MHz, Vs = 0 V Insulation resistance RI-O 1,000 --- --- MW VI-O = 500 VDC, RoH £ 60% IF = 5 mA, RL = 200 W, VDD = 20 V (See note 2.) Output Connection A Current leakage when the relay is open Turn-ON time tON --- 0.8 2.0 ms Turn-OFF time tOFF --- 0.1 0.5 ms 2. Turn-ON and Turn-OFF Times IF 1 6 2 4 RL VDD VOUT IF VOUT 10% t ON 90% t OFF ■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item Symbol Minimum Typical Output dielectric strength VDD --- --- Operating LED forward current IF 5 Continuous load current IO --- Operating temperature Ta - 20 --- Maximum Unit 48 V 7.5 25 mA --- 500 mA 65 °C ■ Engineering Data ■ Safety Precautions Load Current vs. Ambient Temperature Refer to page 6 for precautions common to all G3VM models. Load current (mA) G3VM-61B1(E1) 1,200 Connection C 1,000 800 600 Connection A or connection B 400 200 0 −20 0 20 40 60 80 100 Ambient temperature (°C) 11