Transcript
MOS FET Relays
G3VM-61B1/E1
Analog-switching MOS FET Relay for High Switching Currents, with Dielectric Strength of 2.5 kVAC between I/O. • Upgraded G3VM-61 B/E Series. • Switches minute analog signals. • Leakage current of 1 mA max. when output relay is open.
■ Application Examples
Approval pending
• Measurement devices • Security systems
Note:
• Amusement machines
The actual product is marked differently from the image shown here.
■ List of Models Contact form SPST-NO
Terminals
Load voltage (peak value)
PCB terminals
60 VAC
Model G3VM-61B1
Surface-mounting terminals
Number per stick
Number per tape
50
---
---
1,500
G3VM-61E1 G3VM-61E1(TR)
■ Dimensions Note:
All units are in millimeters unless otherwise indicated.
G3VM-61B1
G3VM-61E1
7.12±0.25
7.12±0.25
6.4±0.25
6.4±0.25 7.62±0.25
7.62±0.25
0.8±0.25 +0.15
3.65 −0.25
+0.15
3.65 −0.25
Note: The actual product is marked differently from the image shown here.
1.2±0.15 0.5±0.1 2.54±0.25
2.5 min.
7.85 to 8.80
Weight: 0.38 g
Note: The actual product is marked differently from the image shown here.
4.0 +0.25 −0.2
1.0 min.
+0.1
0.25 −0.05 1.2±0.15
1.0 min. 10.0 max.
2.54±0.25
Weight: 0.38 g
■ Terminal Arrangement/Internal Connections (Top View) G3VM-61B1
6
5
4
1
2
3
■ PCB Dimensions (Bottom View) G3VM-61B1
2.54
Six 0.8-dia. holes (0.61)
G3VM-61E1
6
5
4
1
2
3
■ Actual Mounting Pad Dimensions (Recommended Value, Top View) G3VM-61E1
2.54
2.54
2.54
8.3 to 8.8
(1.52)
(0.61) (1.52)
1.3 1.5
10
G3VM-61B1/E1
G3VM-61B1/E1
■ Absolute Maximum Ratings (Ta = 25°C) Item Input
Output
Symbol
Rating
Unit
Measurement Conditions
Note:
LED forward current
IF
50
mA
Repetitive peak LED forward current
IFP
1
A
100 ms pulses, 100 pps
LED forward current reduction rate
D IF/°C
-0.5
mA/°C
Ta ³ 25°C
LED reverse voltage
VR
5
V
Connection temperature
Tj
125
°C
Output dielectric strength
VOFF
60
V
Continuous load current
IO
500
mA
Connection A Connection B Connection A
Connection A
1,000 D ION/°C
-0.5
Ta ³ 25°C
mA/°C
Connection B
-0.5
Connection B
-10.0
Connection C Tj
125
°C
Dielectric strength between input and output (See note 1.)
VI-O
2,500
Vrms
Operating temperature
Ta
Connection temperature
Connection Diagram 1
6
2
5
3
4
1
6
2
5
3
4
1
6
2
5
3
4
Load AC or DC
500
Connection C ON current reduction rate
1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on the light-receiving side.
AC for 1 min
-40 to +85
°C
With no icing or condensation
Storage temperature
Tstg
-55 to +125
°C
With no icing or condensation
Soldering temperature (10 s)
---
260
°C
10 s
Connection C
Load DC
Load DC
■ Electrical Characteristics (Ta = 25°C) Item Input
Symbol
Minimum
Typical
Maximum
Unit
Measurement conditions
Note:
LED forward voltage
VF
1.0
1.15
1.3
V
IF = 10 mA
Reverse current
IR
---
---
10
mA
VR = 5 V
Capacity between terminals
CT
---
30
---
pF
V = 0, f = 1 MHz
Trigger LED forward current
IFT
---
1.6
3
mA
IO = 500 mA
Maximum resistance with output ON
RON
---
1
2
W
IF = 5 mA, IO = 500 mA
Connection B
---
0.5
1
W
IF = 5 mA, IO = 500 mA
Connection C
---
0.25
---
W
IF = 5 mA, IO = 1,000 mA
ILEAK
---
---
1.0
mA
VOFF = 60 V
Capacity between I/O terminals
CI-O
---
0.8
---
pF
f = 1 MHz, Vs = 0 V
Insulation resistance
RI-O
1,000
---
---
MW
VI-O = 500 VDC, RoH £ 60% IF = 5 mA, RL = 200 W, VDD = 20 V (See note 2.)
Output
Connection A
Current leakage when the relay is open
Turn-ON time
tON
---
0.8
2.0
ms
Turn-OFF time
tOFF
---
0.1
0.5
ms
2. Turn-ON and Turn-OFF Times IF
1
6
2
4
RL
VDD VOUT
IF
VOUT
10% t ON
90% t OFF
■ Recommended Operating Conditions Use the G3VM under the following conditions so that the Relay will operate properly. Item
Symbol
Minimum
Typical
Output dielectric strength
VDD
---
---
Operating LED forward current
IF
5
Continuous load current
IO
---
Operating temperature
Ta
- 20
---
Maximum
Unit
48
V
7.5
25
mA
---
500
mA
65
°C
■ Engineering Data
■ Safety Precautions
Load Current vs. Ambient Temperature
Refer to page 6 for precautions common to all G3VM models.
Load current (mA)
G3VM-61B1(E1) 1,200 Connection C 1,000
800
600 Connection A or connection B 400
200
0 −20
0
20
40
60 80 100 Ambient temperature (°C)
11