G6S
Surface-mounting Relay
Surface-mounting, double-pole signal switching Relay, with terminals jutting out from both sides of the case • Long terminals for ideal for soldering and mounting reliability. (Surface mounting terminal models) • Space-saving inside-L terminal. (Surface mounting terminal models) • Unique terminal construction allowing the terminal temperature to rise easily, ideal for soldering reliability. (Surface mounting terminal models) • High dielectric strength (2,000 VAC) and impulse withstand voltage between coil and contacts (2,500 V, 2 × 10 μs: Telcordia requirements). • High sensitivity with 140 mW rated power consumption. • Ultra-miniature at 9.4 mm (H) × 7.5 mm (W) × 15 mm (L). • Applicable to IRS using heat-resistant material. • Standard model conforms to UL/CSA standards. • Model with PCB terminals (G6S@-2) is added to this series. • BSI (EN60950) certified models available. (-Y type)
G 6 S
RoHS Compliant
■Model Number Legend
■Application Examples
G6 S @ - @ @ - @ 1
2 3
• • • •
4 3. Terminal Shape None : PCB terminals F : Outside-L surface mounting terminals G : Inside-L surface mounting terminals 4. Approved Standards None : UL, CSA Y : UL, CSA, BSI (EN60950)
1. Relay Function None : Single-side stable U : Single-winding latching K : Double-winding latching 2. Number of poles/ Contact form 2: 2-pole/DPDT (2c)
Telecommunication equipment Measurement devices Office automation machines Audio-visual products.
■Ordering Information ●Surface mounting terminal standard models Relay Function Enclosure rating
Contact form
Single-side stable Model
G6S-2F G6S-2G Fully sealed
DPDT (2c)
Rated coil voltage
Single-winding latching Model
Rated coil voltage
Double-winding latching Model
Rated coil voltage
3 VDC
3 VDC
3 VDC
4.5 VDC
4.5 VDC
4.5 VDC
5 VDC
G6SU-2F G6SU-2G
5 VDC
G6SK-2F G6SK-2G
Minimum packing unit
5 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
50 pcs/tube (400 pcs/reel)
5 VDC G6S-2F-Y G6S-2G-Y
12 VDC
−
−
−
−
24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F 3 VDC Rated coil voltage Note 2.When ordering tape packing, add -TR" to the model number. Be sure since -TR" is not part of the relay model number, it is not marked on the relay case. Note 3.When ordering tape packing, minimum order unit is 2 reels (400pcs × 2 = 800 pcs).
1
G6S
Surface-mounting Relay
●PCB Terminal Standard Models Relay Function
Enclosure rating
Contact form
Single-side stable Model
G6S-2 Fully sealed
DPDT (2c)
Single-winding latching
Rated coil voltage
Model
Rated coil voltage
Double-winding latching Model
Rated coil voltage
3 VDC
3 VDC
3 VDC
4.5 VDC
4.5 VDC
4.5 VDC
G6SU-2
5 VDC
5 VDC
G6SK-2
Minimum packing unit
5 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
50 pcs/tube
5 VDC G6S-2-Y
−
12 VDC
−
−
−
24 VDC Note: When ordering, add the rated coil voltage to the model number. Example: G6S-2 3 VDC Rated coil voltage
■Ratings ●Single-side Stable Model (G6S-2, G6S-2F, G6S-2G) Item Rated voltage
G 6 S
Rated current (mA)
Coil resistance (Ω)
3 VDC
46.7
4.5 VDC
31.0
145
5 VDC
28.1
178
12 VDC
11.7
24 VDC
8.3
●Contacts
Must operate Must release Max. voltage Power voltage (V) voltage (V) (V) consumption (mW) % of rated voltage
Rated voltage
Rated carry current
2A
1,028 2,880
Max. switching voltage
250 VAC, 220 VDC
Max. switching current
2A
Coil resistance (Ω)
3 VDC
33.3
90
22.2
203
20
250
12 VDC
8.3
1,440
24 VDC
6.3
1,152
75% max.
10% min.
170% (at 23°C)
Approx. 140
Approx. 200
Must set voltage (V)
Must reset voltage (V)
Max. voltage Power (V) consumption (mW) % of rated voltage
75% max.
75% max.
180% (at 23°C)
Approx. 100
Approx. 150
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
●Double-winding Latching Model (G6SK-2, G6SK-2F, G6SK-2G) Item Rated voltage
Rated current (mA)
Coil resistance (Ω)
3 VDC
66.6
45
4.5 VDC
44.4
101
40
125
5 VDC 12 VDC
16.7
720
24 VDC
12.5
1,920
Must set voltage (V)
Max. voltage Power (V) consumption (mW) % of rated voltage
75% max.
Must reset voltage (V)
75% max.
170% (at 23°C)
Approx. 200
140% (at 23°C)
Approx. 300
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
●EN60950 certified Model (G6S-2F-Y, G6S-2G-Y, G6S-2-Y) Item Rated voltage 5 VDC
Rated current (mA)
Coil resistance (Ω)
40
125
12 VDC
16.7
720
24 VDC
9.6
2,504
Must operate Must release Max. voltage Power voltage (V) voltage (V) (V) consumption (mW) % of rated voltage 75% max.
10% min.
170% (at 23°C)
Approx. 200 Approx. 230
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2
Contact material Ag (Au-Alloy) 0.5 A at 125 VAC; 2 A at 30 VDC
4.5 VDC 5 VDC
Resistive load Bifurcated crossbar
Rated load
200% (at 23°C)
●Single-winding Latching Model (G6SU-2, G6SU-2F, G6SU-2G) Rated current (mA)
Load
Contact type
64.3
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
Item
Item
G6S
Surface-mounting Relay
■Characteristics Item
Relay Function
Single-side Stable G6S-2, G6S-2F, G6S-2G
Single-winding Latching Double-winding Latching G6SU-2, G6SU-2F, G6SK-2, G6SK-2F, G6SU-2G G6SK-2G 75 mΩ max. 4 ms max. 4 ms max. − 10 ms 1,000 MΩ min. (at 500 VDC) 1,000 VAC, 50/60 Hz for 1 2,000 VAC, 50/60 Hz for 1 min min 1,500 VAC, 50/60 Hz for 1 min 1,500 VAC, 50/60 Hz for 1 min 500 VAC, 50/60 Hz for 1 − min
Contact resistance *1 Operate (set) time Release (reset) time Min. set/reset pulse width Insulation resistance *2 Between coil and contacts Between contacts of different polarity Between contacts of the same polarity
Dielectric strength
Between set and reset coil
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)
Between coil and contacts
Impulse withstand voltage Vibration resistance Shock resistance Durability
EN60950 certified G6S-2F-Y, G6S-2G-Y, G6S-2-Y
− 2,000 VAC, 50/60 Hz for 1 min
− 2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs)
1,500 V (10 × 160 μs)
2,500 V (2 × 10 μs); 1,500 V (10 × 160 μs) 1,500 V (10 × 160 μs) 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 1,000 m/s2 750 m/s2 100,000,000 operations min. (at 36,000 operations/hr) 100,000 operations min. for AC (at 1,800 operations/h with rated load) 100,000 operations min. for DC (at 1,200 operations/h with rated load) 10 μA at 10 m VDC -40°C to 85°C (with no icing or condensation), and -40°C to 70°C (with no icing or condensation) only for double-winding latching 24 VDC type and EN60950 standard approved 24 VDC type 5% to 85% Approx. 2 g
Between contacts of different polarity Between contacts of the same polarity Destruction Malfunction Destruction Malfunction Mechanical Electrical
Failure rate (P level) (reference value) *3 Ambient operating temperature Ambient operating humidity Weight
G 6 S
Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength (except between the set and reset coil). *3. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
■Engineering Data
7 5 3
AC resistive load 1
500
Maximum voltage (%)
10
300 30 VDC resistive load Ambient temperature 23°C Switching frequency: 1,200 operations/h
100 50
0.3
0.1 10
30
1 0
300 500 700 1,000
150
250 G6SU 200
150 G6SK 12 VDC max.
5 125 VAC resistive load Ambient temperature 23°C 3 Switching frequency: 1,800 operations/h
50 70 100
200
G6S 24 VDC G6S-Y G6S-Y 12 VDC max. 24 VDC
100
10 DC resistive load
G6S 4.5 to 12 VDC
30
0.7 0.5
250
●Ambient Temperature vs. Maximum Voltage (Latching) Maximum voltage (%)
●Ambient Temperature vs. Maximum Voltage (Single-side Stable)
●Durability G6S-2F(G) Durability (×104 operations)
Switching current (A)
●Maximum Switching Capacity
0.5
1
1.5
Switching voltage (V)
2
50
50
2.5
0 −40
3
G6SK 24 VDC
100
−20
0
20
40
60
80
0 −40
100
−20
0
20
40
60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
Switching current (A)
Note: “Maximum voltage” is the maximum voltage that can be applied to the Relay coil.
G6S 12 VDC max.
3
G6SU 12 VDC max. 2 G6SU 24 VDC G6SK 12 VDC max.
G6S-Y 24 VDC 1
100
Y 1,000
X min.
40
50
60
70
90
100
Ambient temperature (°C)
0
40
50
60
80
90
100
Ambient temperature (°C)
De400 energized
Z 1,000
200
200
40
20
70
600
X 1,000
60
Must operate voltage Must release voltage 80
Energized
800
max.
80
max. X min. G6SK 24 VDC
●Shock Malfunction G6S-2F(G)
Sample: G6S-2F Number of Relays: 10 pcs
1 G6S 24 VDC G6S-Y 12 VDC max.
0
On the basis of rated voltage (%)
3
2
●Ambient Temperature vs. Must Operate or Must Release Voltage G6S-2F(G)
●Ambient Temperature vs. Switching Current (Latching) Switching current (A)
Switching current (A)
●Ambient Temperature vs. Switching Current (Single-side Stable)
0 −60
−40 −20
0
20
40
60
80
100 120
Ambient temperature (°C)
1,000 Z' Shock direction X X' Y Z Z'
400
1,000 X'
600 800 1,000
Y'
Unit: m/s2 Sample: G6S-2F Number of Relays: 10 pcs
Y'
Conditions: Shock is applied in ±X, ±Y, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions.
3
G6S
Surface-mounting Relay
min.
Must operate voltage
500 300
Sample: G6S-2F Number of Relays: 10 pcs Measurement conditions: NO contact - wire-spring relay load at 48 VDC, 120mA (with ARC-killer) NC contact - resistive load at 48 VDC, 60mA Switching frequency: 3,600 operations/h
100
40
Must release voltage
20
max.
50
min.
30
Contact resistance
●Electrical Endurance (Contact Resistance) *1 G6S-2F(G) Contact resistance (mΩ)
max. 60
1,000
On the basis of rated voltage (%)
100 Sample: G6S-2F Number of Relays: 10 pcs Measurement conditions: NO contact - wire-spring relay load at 48 VDC, 120mA (with ARC-killer) 80 NC contact - resistive load at 48 VDC, 60mA Switching frequency: 3,600 operations/h
●Electrical Endurance (with Must Operate and Must Release Voltage) *1 G6S-2F(G)
●Electrical Endurance (Contact Resistance) *1 G6S-2F(G) Contact resistance (mΩ)
On the basis of rated voltage (%)
●Electrical Endurance (with Must Operate and Must Release Voltage) *1 G6S-2F(G)
1,000
100
Sample: G6S-2F Number of Relays: 10 pcs Test conditions: 2A resistive load at 30-VDC with an operation rate of 50% 80 Switching frequency: 1,200 operations/h max. 60
min.
Must operate voltage
Sample: G6S-2F Number of Relays: 10 pcs Test conditions: 2A resistive load at 30-VDC with an operation rate of 50% 300 Switching frequency: 1,200 operations/h
NO contact NC contact
500
100 40
Contact resistance 50
max. min. max. min.
max. max. min. min.
max. 20 Must release voltage
30
min.
NO contact NC contact 10 50
0 100
300 500
1,000
5,000
100
300 500
1,000
Operating frequency (×10 operations)
Contact resistance (mΩ)
●Contact Reliability Test (Contact Resistance) *1, *2 G6S-2F(G)
3
5
10
30 50
100
10 1
300 500
Number of contacts
NO contact NC contact
3
5
10
60 Sample: G6S-2F Number of Relays: 50 pcs
Must operate time Must release time
40
30 50
100
300 500
Operating frequency (×103 operations)
Operating frequency (×103 operations)
●Must Operate and Must Release Time Distribution *1 G6S-2F(G)
1,000
Sample: G6S-2F Number of Relays: 10 pcs 500 Test conditions: 10 μA resistive load at 10 m VDC with an operation rate of 50% 300 Switching frequency: 7,200 operations/h
0 1
5,000
Operating frequency (×103 operations)
3
●Distribution of Bounce Time *1 G6S-2F(G) Number of contacts
50
60 Sample: G6S-2F Number of Relays: 50 pcs
Operating bounce time Release bounce time
40
100 max. max. 20
min. min.
30
10 10
30 50 100
300 500 1,000
20
0.5
0
10,000 50,000
1
1.5
2
2.5
Operating frequency (×103 operations)
●External Magnetic Interference (Average value) G6S-2F(G)
Energized
+10 0 −20 −30
Change rate on the basis of initial value (%)
Sample
Energized
*1. *2. *3.
4
Change rate on the basis of initial value (%)
Not energized
1.5
2
2.5
S
N
S
N
+20
+10
+30 S
N
S
N
+20
+10
3
Time (ms)
(Average value) +30 S
N
S
N
+20
+10
0
0
0
−10
−10
−10
Average value Initial stage
Test
+10
−20
0 −20 −30
+30 +20
−30 −1,200
Average value
−800
−400
0
400
Test
Sample: G6S-2F Number of Relays: 10 pcs
20
+10 0
+30 +20
−400
0
400
800 1,200
Sample: G6S-2F Number of Relays:10 pcs −30 −1,200 −800 −400 0
●High-frequency Characteristics (Insertion Loss) *1, *3 G6S-2F(G) (Average value (initial)) 0
0.4
Must operate voltage Must release voltage 400
800 1,200
External magnetic field (A/m)
External magnetic field (A/m)
●High-frequency Characteristics (Return Loss, V.SWR) *1, *3 G6S-2F(G) (Average value (initial)) 0
2.5
Sample: G6S-2F Number of Relays: 10 pcs
5
2.0
10 1.5 V.SWR
40
15
Average value
1.2 Initial stage
1.0
Test
20 60 1.6
+10 −10
80 Average value
10
30 50
100
300 500 1,000
5,000
Frequency (MHz)
Return loss
25
0 −20 −30
−800
0.8
−10 −20 −30
−30 −1,200
External magnetic field (A/m)
0
Must operate voltage Must release voltage
Sample: G6S-2F Number of Relays:10 pcs
800 1,200
●High-frequency Characteristics (Isolation) *1, *2 G6S-2F(G) (Average value (initial))
Initial stage
−20
−20 Must operate voltage Must release voltage
Sample: G6S-2F Number of Relays:10 pcs
−10
Must operate voltage Must release voltage
Sample
1
−10
●Mutual Magnetic Interference G6S-2F(G) 4.64 mm
0.5
(Average value) Rate of variability (%)
Test
0
Return loss (dB)
Sample
+30 +20
Initial stage
+30
Insertion loss (dB)
Not energized
+30 +20
Isolation (dB)
Sample
Change rate on the basis of initial value (%)
2.22 mm
Change rate on the basis of initial value (%)
Must operate voltage Must release voltage
Rate of variability (%)
●Mutual Magnetic Interference G6S-2F(G)
3
Time (ms)
2.0
Sample: G6S-2F Number of Relays: 10 pcs 10
30 50
100
300 500 1,000
5,000
Frequency (MHz)
30
10
30 50
0.5
100
300 500 1,000
5,000
0
Frequency (MHz)
The tests were conducted at an ambient temperature of 23°C. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. High-frequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including durability, in the actual machine before use.
V.SWR
G 6 S
Rate of variability (%)
50
G6S
Surface-mounting Relay
■Dimensions Single-side Stable G6S-2F G6S-2F-Y
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
9.2±0.2
2.54
7.3±0.2
5.08
2.54
Orientation mark
2.2
0.65
Terminal Arrangement/ Internal Connections (Top View)
12
10
9
8
1
3
4
5
8
0.25 +0.5 9.2−0.3
0.5 2.54
5.08 2.54
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6S-2G G6S-2G-Y
1
Note: Check carefully the coil polarity of the Relay.
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
7.3±0.2
Orientation mark
2.54 5.08 9.2±0.2
2.54
0.65 2.2
0.25
+0.3 4.9−0.5
2.54 2.54
1
PCB Mounting Holes (Bottom View) 2.54 14.8±0.2
9
8
1
3
4
5
G 6 S
Terminal Arrangement/ Internal Connections (Bottom View)
Eight, 1-dia. holes
7.3±0.2
Orientation mark 2.54
9.2±0.2
10
Note: Check carefully the coil polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6S-2 G6S-2-Y
12 6.1
0.5 5.08
Terminal Arrangement/ Internal Connections (Top View)
1
3
4
5
12
10
9
8
0.65 5.08±0.1 2.95 0.5
0.25
5.08
5.08
2.54 2.54
(1.11) 5.08
(1.05)
Note: Each value has a tolerance of ±0.3 mm.
Single-winding Latching G6SU-2F
2.54 2.54
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
7.3±0.2
Note: Check carefully the coil polarity of the Relay.
2.54 5.08
Terminal Arrangement/ Internal Connections (Top View) Orientation mark
2.54
12 9.2±0.2
0.65
2.2 0.25
8
2.54 2.54
1
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
7.3±0.2
2.54 5.08
2.2
2.54
PCB Mounting Holes (Bottom View) 2.54 14.8±0.2
8
3
4
5
Terminal Arrangement/ Internal Connections (Bottom View)
Eight, 1-dia. holes
7.3±0.2
Orientation mark 2.54
9.2±0.2
9
Note: Check carefully the coil polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6SU-2
10
S R 1
1
+0.3 4.9−0.5
2.54
5
6.1
0.25 0.5
4
Orientation mark
2.54
0.65
5.08
3
Terminal Arrangement/ Internal Connections (Top View)
12 9.2±0.2
8
Note: Check carefully the coil polarity of the Relay.
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6SU-2G
9
S R
1 +0.5 9.2−0.3
0.5 5.08
10
1
3
4
5
10
9
8
0.65 5.08±0.1 2.95
S R 12
0.5
0.25
5.08
2.54 2.54
(1.11) 5.08
(1.05)
5.08
2.54
Note: Check carefully the coil polarity of the Relay.
2.54
Note: Each value has a tolerance of ±0.3 mm.
5
G6S
Surface-mounting Relay
Double-winding Latching G6SK-2F
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
7.3±0.2
2.54 2.54
Terminal Arrangement/ Internal Connections (Top View) Orientation mark
5.08
2.54 12
9.2±0.2
0.65 2.2
0.25
1
2.54 2.54 2.54
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6SK-2G 7.3±0.2
1
7
R 3
4
5
6
Terminal Arrangement/ Internal Connections (Top View) Orientation mark
2.54 2.54 5.08
2.54 12
9.2±0.2
8
Note: Check carefully the coil polarity of the Relay.
Mounting Dimensions (Top View) Tolerance: ±0.1 mm 14.8±0.2
9
S
8
+0.5 9.2−0.3
0.5 5.08
10
0.65
2.2
6.1
10
9
8
7
S
R
0.25 1
0.5 2.54 2.54
1
+0.3 4.9−0.5
2.54
5.08
Note 1. Each value has a tolerance of ±0.3 mm. Note 2.The coplanarity of the terminals is 0.1 mm max.
G6SK-2
PCB Mounting Holes (Bottom View)
G 6 S
2.54 14.8±0.2
4
5
6
Terminal Arrangement/ Internal Connections (Bottom View)
Ten, 1-dia. holes
7.3±0.2
Orientation mark 2.54
9.2±0.2
3
Note: Check carefully the coil polarity of the Relay.
1
3
4
5
6
0.65 5.08±0.1
S
R
(1.11)
2.95
12 0.5
0.25
5.08
2.54
5.08
2.54 2.54
5.08
(1.05)
10
9
8
7
Note: Check carefully the coil polarity of the Relay.
2.54 2.54 2.54
Note: Each value has a tolerance of ±0.3 mm.
■Tape Packing (Surface Mounting Terminal Models) • When ordering Relays in tape packing, add the prefix “-TR” to the model number, otherwise the Relays in tube packing will be provided. Relays per Reel: 400 pcs (3) Carrie Tape Dimensions Minimum ordering unit: 2 reels (800 pcs) G6S-2F(-Y), G6SU-2F, G6SK-2F
(1) Direction of Relay Insertion
2±0.1
Orientation mark
Top tape (cover tape)
9.7±0.1
4±0.1
1.5+0.1 −0
1.75±0.1
0.4±0.05
11.5±0.1 24±0.3
15.3
Pulling direction
16±0.1
Carrier tape
Embossed tape
9.7
G6S-2G(-Y), G6SU-2G, G6SK-2G
(2) Reel Dimensions 2±0.3 21±0.5
13±0.2
9.7±0.1
4±0.1
1.5+0.1 −0
25.5±0.5 29.5±1.0
2±0.1
1.75±0.1
11.5±0.1 24±0.3 80
15.3
330
16±0.1 R1
6
7.8
0.4±0.05
G6S
Surface-mounting Relay
■Recommended Soldering Method Temperature (°C)
(1) IRS Method (Mounting Solder: Lead)
• The thickness of cream solder to be applied should be within a range between 150 and 200 μm on OMRON’s recommended PCB pattern. • In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the left side.
Soldering
220 to 240
Correct Soldering
180 to 200
Incorrect Soldering Relay Terminal
Preheating 150
Land Heel fillet is formed
90 to 120
PCB
Solder
20 to 30
Insufficient amount of solder
Time (s)
(The temperature profile indicates the temperature on the circuit board surface.)
Excessive amount of solder
Visually check that the Relay is properly soldered.
Temperature (°C)
(2) IRS Method (Mounting Solder: Lead-free)
Uppwe surface of case (peak): 255°C max. Soldering
250 max.
G 6 S
230 180
Preheating
150
Relay terminal section
120 max.
30 max. Time (s)
(The temperature profile indicates the temperature on the PCB.)
■Approved Standards UL recognized: CSA certified:
■Precautions
(File No. E41515) (File No. LR31928)
• Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
Contact form
Coil ratings
Contact ratings
Number of test operations
DPDT (2c)
2 to 48 VDC
3 A, 30 VDC at 40°C 0.3 A, 110 VDC at 40°C 0.5 A, 125 VAC at 40°C
6,000
BSI (EN60950) (File No.8064) Contact form
Isolation category
Voltage
DPDT (2c)
Supplementary Insulation
250 VAC
• Long-term Continuously ON Contacts • Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. We recommend using a latching relay (magnetic-holding relay) in this kind of circuit. If a single-side stable model must be used in this kind of circuit, we recommend using a fail-safe circuit design that provides protection against contact failure or coil burnout. • Relay Handling • Use the Relay as soon as possible after opening the moistureproof package. If the Relay is left for a long time after opening the moisture-proof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moisture-proof package, place it into the original package and sealed the package with adhesive tape. • When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40°C. Do not put the Relay in a cold cleaning bath immediately after soldering. • Claw Securing Force During Automatic Mounting • During automatic insertion of Relays, be sure to set the securing force of each claw to the following so that the Relay’s characteristics will be maintained. C A
B
Dimension A: 1.96 N max. Dimension B: 4.90 N max. Dimension C: 1.96 N max.
7
G6S
Surface-mounting Relay
G 6 S
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation Electronic and Mechanical Components Company
8
Contact: www.omron.com/ecb
Cat. No. K093-E1-07 0314(0207)(O)