Preview only show first 10 pages with watermark. For full document please download

Ga-10 / Gh

   EMBED


Share

Transcript

Micro-size Inductive Proximity Sensor Amplifier-separated Product is discontinuedInductive Sensors Diagnosis Self-diagnosis Oil resistant Metal embedding With adjuster possible GXL INDUCTIVE PROXIMITY SENSORS GA-10 SERIES GH SERIES Slim & small Reliable Accurate The amplifier is extremely slim, just 10 mm 0.394 in thick. This results in a co m pac t s iz e e v e n i f s e v e ra l amplifiers are mounted in a row. Moreover, the sensor head is also extremely small, the smallest being just "2.8 mm "0.110 in (GH-2S). The sensor heads (GH-3S, GH-5S, GH-8S and GH-F8S) have IP67 protection. Further, the tightening torque has been significantly improved due to its thick case. Fine adjustments are possible by its 18-turn, wide adjustment range sensitivity adjuster. Besides, its repeatability is 1 !m 0.039 mil or less and its temperature characteristics have been improved to twice as good as those of conventional models. Hence, it is suitable for high accuracy positioning applications. GH-5S Conventional models GH-2S Tightening torque 0.14 Nm or less mes 5.6 tirox. app 10 GA-10 series Within5 % 5 0 5 10 Conventional model Within10 % Tightening torque 0.78 Nm or less Comparison of repeatability "2.8 mm "0.110 in 10 mm 0.394 in Conventional model mes 0.5 ti GH series GX Repeatability 2 !m 0.079 mil or less Repeatability 1 !m 0.039 mil or less Screw tightening type available GA-10/GH Amplifier-separated Comparison of temperature characteristics (GA-10 series) Variation (%) GA-14 GX-N GX-U/FU GL-18H/18HL GL-N12 Amplifier Built-in GL-8/8U GL-6 High accuracy sensing with a slim-size sensor GA-15 GA-15 enables sensor head connection by screw tightening. Moreover, since the cover of the connecting portion is transparent, it is possible to confirm whether the connection is proper. Disconnection alarm indicator Wire-saving If the sensor head cable is damaged, or misconnected, the disconnection alarm indicator (orange LED) lights up for your attention. Amplifier with a plug-in connector, which is connectable to the sensor block of an S-LINK system, or to the sensor block for simple wiring SL-BMW or SL-BW, or to a mating cable, is also available. Wrong clamping Shield wire Screw for cable clamp Disconnection Mating cable CN-54-C2 (2 m 6.562 ft long) CN-54-C5 (5 m 16.404 ft long) Cable core Transparent cover Disconnection alarm indicator (Orange) Plug-in connector type GA-14J, GA-15J Note: The above photograph shows GA-14J. 754 APPLICATIONS Aligning press molds The sensor detects even a minute misalignment. Detecting vibration of parts-feeder The sensor detects whether the feeder is vibrating. GXL Inspecting presence of washer The sensor detects the presence / absence of a washer by the height of the spring-loaded rod. INDUCTIVE PROXIMITY SENSORS GA-10/GH GOOD Spring-loaded rod BAD GL-6 Contact pin Washer absent GL-8/8U ORDER GUIDE Sensor heads Type Appearance (mm in) Sensing range (Note) Model No. Hysteresis GH-2S 1.8 mm 0.071 in (0 to 0.8 mm 0 to 0.031 in) GH-3S 0.07 mm 0.0028 in or less "3.8 "0.150 15 0.591 0.05 mm 0.0020 in or less "5.4 "0.213 15 0.591 "8 "0.315 15 0.591 2.4 mm 0.094 in (0 to 1.0 mm 0 to 0.039 in) (0 to 2.0 mm 0 to 0.079 in) 4.0mm 0.157 in GH-5S GH-8S 0.04 mm 0.0016 in or less GH-F8S GX-U/FU Spatterresistant type Cylindrical type 12 0.472 1.2 mm 0.047 in (0 to 0.6 mm 0 to 0.024 in) Stable sensing range Amplifier Built-in GL-18H/18HL GL-N12 Maximum operation distance "2.8 "0.110 Note: The stable sensing range represents the sensing range for which the sensor can satisfy all the given specifications with the standard sensing object. The maximum operation distance represents the maximum distance for which the sensor can detect the standard sensing object at20 C 68 F constant ambient temperature. Usage within the stable sensing range is recommended for accurate sensing applications. GA-15 12 to 24 V DC10 % Output NPN open-collector transistor GX GA-14 Supply voltage Amplifier-separated GA-10/GH Model No. One-touch clamping Appearance Screw tightening Type GX-N Amplifiers 755 INDUCTIVE PROXIMITY SENSORS GA-10/GH ORDER GUIDE 5 m 16.404 ft cable length type and plug-in connector type 5 m 16.404 ft cable length type(standard: 2 m 6.562 ft) and plug-in connector type (standard: cable type) are also available. GL-6 GXL • Table of Model Nos. Type Standard 5 m 16.404 ft cable length type Plug-in connector type One-touch clamping GA-14 GA-14-C5 GA-14J Screw tightening GA-15 GA-15-C5 GA-15J GL-8/8U Plug-in connector type is usable with the sensor & wire-saving link system S-LINK, sensor block for simple wiring SL-BMW or SL-BW, or with connector attached cable CN-54-C2 or CN-54-C5. Connector attached cable GX-U/FU GL-18H/18HL GL-N12 Amplifier Built-in CN-54-C2 (2 m 6.562 ft long) CN-54-C5 (5 m 16.404 ft long) Sensor & wire-saving link system S-LINK Sensor block for simple wiring SL-BMW, SL-BW (Refer to p.1030l for details.) (Refer to p.882l for details.) Accessory • MS-DIN-2 (Amplifier mounting bracket) OPTIONS Sensor head mounting bracket Sensor head mounting bracket GA-10/GH Amplifier-separated GX GX-N Designation 756 Model No. Description MS-SS3 Mounting bracket for GH-3S MS-SS5 Mounting bracket for GH-5S MS-SS8 Mounting bracket for GH-8S • MS-SS3 • MS-SS5 • MS-SS8 The sensor head can be easily fixed. SPECIFICATIONS Amplifiers Supply voltage Current consumption Sensing output Output operation Short-circuit protection Disconnection alarm output Output operation Screw tightening GA-14 GA-15 GH series GXL Applicable sensor head One-touch clamping 12 to 24 V DC10 % Ripple P-P 10 % or less 25 mA or less NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between sensing output and 0 V) • Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) GL-6 Model No. Switchable either Normally open or Normally closed Incorporated NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between disconnection alarm output and 0 V) • Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) GL-8/8U Type Item INDUCTIVE PROXIMITY SENSORS GA-10/GH ON when the sensor head cable is disconnected or misconnected Disconnection alarm indicator Environmental resistance Sensitivity adjuster Ambient temperature Ambient humidity Noise immunity Voltage withstandability 3.3 kHz Red LED (lights up when the sensing output is ON) Orange LED (lights up when the disconnection alarm output is ON) 18-turn potentiometer 10 to60 C 14 to140 F (No dew condensation or icing allowed), Storage :20 to70 C 4 to158 F 35 to 85 % RH, Storage: 35 to 85 % RH Power line: 240 Vp, 10 ms cycle and 0.5 !s pulse width; Radiation: 300 Vp, 10 ms cycle and 0.5 !s pulse width (with noise simulator) 1,000 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each Shock resistance Temperature characteristics (Note) Material Cable Cable extension Weight Accessories 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each Within5 % Enclosure: Heat-resistant ABS, Cover: Polycarbonate, Cable lock lever: PPS (GA-14 only), DIN rail stopper: POM GX-U/FU Operation indicator 0.2 mm2 4-core cabtyre cable, 2 m 6.562 ft long Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. GX-N Max. response frequency Amplifier Built-in GL-18H/18HL GL-N12 Short-circuit protection 65 g approx. MS-DIN-2 (Amplifier mounting bracket): 1 pc., Adjusting screwdriver: 1 pc. Amplifier-separated GA-10/GH GX Note: The value of the temperature characteristics gives the variation in the operation distance, that has been set within the stable sensing range at20 C68 F, for an ambient temperature drift from 0 to55 C32 to131 F. 757 INDUCTIVE PROXIMITY SENSORS GA-10/GH SPECIFICATIONS Sensor heads Type GXL Item Cylindrical type Model No. GH-2S 0 to 0.6 mm 0 to 0.024 in 0 to 0.8 mm 0 to 0.031 in 0 to 1.0 mm 0 to 0.039 in 1.2 mm 0.047 in GH-F8S 0 to 2.0 mm 0 to 0.079 in 2.4 mm 0.094 in 4.0 mm 0.157 in Iron sheet 1010t 1 mm 0.3940.394t 0.039 in 0.05 mm 0.002 in or less Repeatability (Note 2) Environmental resistance GL-6 GL-8/8U 0.07 mm 0.003 in or less 0.04mm 0.002 in or less Along sensing axis, perpendicular to sensing axis: 1!m or less Protection IP50 (IEC) IP67 (IEC), IP67g (JEM) 10 to60 C 14 to140 F, Storage:20 to70 C4 to158 F Ambient temperature 35 to 85 % RH, Storage: 35 to 85 % RH Ambient humidity 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each Vibration resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for five times each Shock resistance Within7 % Temperature characteristics (Note 3) Within5 % Within4 % Enclosure: Stainless steel (SUS303) Enclosure: Stainless steel (SUS303) Enclosure: Stainless steel (SUS303) Enclosure: Stainless steel (SUS303) Enclosure: Stainless steel (SUS303) Sensing part: PVC Sensing part: ABS Sensing part: PAR Sensing part: ABS Sensing part: Fluorine resin Material Spatter resistant cable (cable sheath: fluorine resin), 3 m 9.843 ft long Oil resistant high-frequency coaxial cable, 3 m 9.843 ft long (Note 4) Cable 15 g approx. Weight 30 g approx. 40 g approx. 55 g approx. Notes: 1) The stable sensing range represents the sensing range for which the sensor can satisfy all the given specifications with the standard sensing object. The maximum operation distance represents the maximum distance for which the sensor can detect the standard sensing object at20 C68 F constant ambient temperature. Usage within the stable sensing range is recommended for accurate sensing applications. Notes: 2) Value is given for the stable sensing range. Notes: 3) The value represents the variation in the operation distance, that has been set within the stable sensing range at20 C68 F, for an ambient temperature drift from 0 to55 C32 to131 F. Notes: 4) The length of the sensor head cable cannot be changed. I/O CIRCUIT AND WIRING DIAGRAMS I/O circuit diagram Wiring diagram Color code Tr1 ZD1 Tr2 Brown (Brown) V D Sensor circuit GL-18H/18HL GL-N12 Amplifier Built-in 1.8 mm 0.071 in Iron sheet 55t 1 mm 0.1970.197t 0.039 in Hysteresis (Note 2) GX-U/FU GH-8S GA-10 series Stable sensing range (Note 1) Standard sensing object GX-N Spatter-resistant type GH-5S Applicable amplifier Max. operation distance (Note 1) ZD2 Internal circuit GX GH-3S Load Load (Black) Sensing output Load 100 mA max. (Orange) Disconnection alarm output (Blue) 0 V Black   12 to 24 V DC 10 % 100 mA max. Blue Users’ circuit Symbols ... D: Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor GA-10/GH Amplifier-separated Pin position of plug-in connector type (GA-14J, GA-15J) Sensing output Disconnection alarm output 758 Orange V 0V Load   12 to 24 V DC 10 % SENSING CHARACTERISTICS (TYPICAL) GH-2S 1 0 1 2 0.039 0.039 0.079 Center Left Right Operating point ?(mm in) 0 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) ( The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 0.6 mm 0.024 in. ) 20 0.787 GH-3S Correlation between sensing object size and sensing range The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 0.8 mm 0.031 in. Standard sensing object Iron sheet 55t 1 mm 0.1970.197t 0.039 in # 1 L 0.039 0.5 0.020 0 2 0.079 Sensing range L (mm in) Setting distance L (mm in) Sensing field 1 0.039 L Sensing object aa mm aa in t 1 mm t 0.039 in Iron Stainless steel (SUS304) 0.5 0.020 Brass Aluminum 1 0 1 2 0.039 0.039 0.079 Center Left Right Operating point ?(mm in) 0 GL-6 0 2 0.079 Iron Stainless steel (SUS304) Brass Aluminum 0.5 0.020 GL-8/8U 0.5 0.020 1 0.039 As the sensing object size becomes smaller than the standard size (iron sheet 55t 1 mm 0.1970.197t 0.039 in), the sensing range shortens as shown in the left figure. Sensing object aa mm aa in t 1 mm t 0.039 in 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 55t 1 mm 0.1970.197t 0.039 in), the sensing range shortens as shown in the left figure. ( The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 0.8 mm 0.031 in. ) 20 0.787 Amplifier Built-in GL-18H/18HL GL-N12 1 0.039 L GXL Correlation between sensing object size and sensing range The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 0.6 mm 0.024 in. Standard sensing object Iron sheet 55t1mm 0.1970.197t 0.039 in # L Sensing range L (mm in) Setting distance L (mm in) Sensing field INDUCTIVE PROXIMITY SENSORS GA-10/GH # L 0.5 0.020 0 4 0.157 2 0 2 4 0.079 0.079 0.157 Center Left Right Operating point ?(mm in) Iron 1 0.039 Stainless steel (SUS304) 0.5 0.020 Brass Aluminum L 0 t 1 mm t 0.039 in Sensing object aa mm aa in 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 55t 1 mm 0.1970.197t 0.039 in), the sensing range shortens as shown in the left figure. ( The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 1.0 mm 0.039 in. ) 20 0.787 GX Setting distance L (mm in) 1 0.039 The graph on the left is plotted with the sensitivity adjusted so as to just detect a 55t 1 mm 0.1970.197t 0.039 in iron sheet placed at a distance of 1.0 mm 0.039 in. Sensing range L (mm in) Correlation between sensing object size and sensing range Standard sensing object Iron sheet 55t 1 mm 0.1970.197t 0.039 in GX-N Sensing field GX-U/FU GH-5S Sensing field Setting distance L (mm in) 2 0.079 # L 1 0.039 0 10 0.394 5 0 5 10 0.197 0.197 0.394 Center Left Right Operating point ?(mm in) The graph on the left is plotted with the sensitivity adjusted so as to just detect a 1010t 1 mm 0.3940.394t 0.039 in iron sheet placed at a distance of 2.0 mm 0.079 in. Sensing range L (mm in) Correlation between sensing object size and sensing range Standard sensing object Iron sheet 1010t 1 mm 0.3940.394t 0.039 in Iron 2 0.079 Stainless steel (SUS304) 1 0.039 Brass L 0 Aluminum t 1 mm t 0.039 in Sensing object aa mm aa in 5 10 15 0.197 0.394 0.591 Sensing object side length a (mm in) As the sensing object size becomes smaller than the standard size (iron sheet 10  10  t 1 mm 0.394  0.394  t 0.039 in), the sensing range shortens as shown in the left figure. ( The graph on the left is plotted with the sensitivity adjusted so as to just detect a 1010t 1 mm 0.3940.394t 0.039 in iron sheet placed at a distance of 2.0 mm 0.079 in. 20 0.787 759 ) Amplifier-separated GA-10/GH GH-8S GH-F8S PRECAUTIONS FOR PROPER USE Refer to p.1152l for general precautions. This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal object detection sensor. Mounting of the amplifier Cable • Do not shorten or lengthen the sensor head cable. How to mount the amplifier 2 Open the cover. • Make sure to connect the GH sensor head to the GA-10 GL-6 GL-8/8U GL-18H/18HL GL-N12 Amplifier Built-in GX-U/FU 1 Fit the rear part of the amplifier on the attached amplifier mounting bracket (MS-DIN-2) or a 35 mm 1.378 in width 2 1 DIN rail. Attached amplifier mounting 2 Press down the front part of the amplifier bracket or 35 mm 1.378 in on the attached amplifier mounting width DIN rail bracket (MS-DIN-2) or DIN rail to fit it. How to remove the amplifier 2 1 1 Push the amplifier forward. 2 Lift up the front part of the amplifier to remove it. Note: Please take care that if the front part is lifted without pushing the amplifier forwards, the hooks on the rear portion of the mounting section are likely to break. GA-14 1 Prepare the cable end as shown in 1 Cable the right figure, and twist the shield sheath wire and the cable core inner conductor, respectively. If they are Cable not twisted properly, they may not core enter the inlets resulting in misconnection. GX-N Shield wire 151 mm 0.5910.039 in Cover Shield wire 4 2 3 Screw for cable clamp Shield wire 4 Cable core 5 Screw for cable clamp 6 Cover Note: Take care since the shield wire may get slightly exposed. How to mount the sensor head • The tightening torque should be as given below. Make sure to use a set screw with a cup-point end. Set screw (M3 or less) Model No. A Cable core 3 Tightening torque A (mm in) GH-2S 0.17 N  m 3 0.118 or more GH-3S 0.17 N  m 4 0.157 or more GH-5S 0.78 N  m 5 0.197 or more GH-8S GH-F8S 0.59 N  m 5 0.197 or more Note: Do not tighten excessively. • If there is a metal near the sensor head, it may affect the sensing performance. Keep the minimum distance specified in the table below. Cable lock lever 5 6 Cover Note: If there is a shred of the cable left inside the cable inlet, remove it before connecting the sensor head cables. Turn the amplifier upside down, and tap it around the holes. If the shred still remains, peel the bottom seal off the amplifier, and drop it out. (The seal is reusable.) Cable shred 760 3 Loosen the screw for the cable clamp by turning it counterclockwise. 4 Referring to the cable connection diagram at the side of the amplifier, insert the shield wire and the cable core straight into the inlets, without bending them. 5 Tighten the screw for the cable clamp by turning it clockwise. The tightening torque should be 0.15 Nm or less. 2 6 Make sure to fit the cover on the amplifier after connecting the sensor head. Seal Cover 51 mm 0.1970.039 in Distance from surrounding metal 5 Flip up the cable lock lever to lock the cable. Seal 151 mm 0.5910.039 in Mounting of the sensor head 51 mm 0.1970.039 in Note: Peel off the cable sheath and notice that along with the core wire itself, there is another shield wire. Separate the shield wire from the core wire and proceed with mounting. 3 Flip the cable lock lever down. 4 Referring to the cable connection diagram at the side of the amplifier, insert the shield wire and the cable core straight into the inlets, without bending them. Shield wire 6 Make sure to fit the cover on the amplifier after connecting the sensor head. Sensor head cable connection 2 Open the cover. GX 1 Prepare the cable end as shown in 1 the right figure, and twist the shield Cable sheath wire and the cable core inner conductor, respectively. Note: Peel off the cable sheath and notice that core along with the core wire itself, there is another shield wire. Separate the shield wire from the core wire and proceed with mounting. amplifier correctly, or malfunction will occur. GA-10/GH Amplifier-separated GA-15 Background metal INDUCTIVE PROXIMITY SENSORS GXL GA-10/GH Model No. B (mm in) B GH-2S 3 0.118 GH-3S 4 0.157 GH-5S 5 0.197 GH-8S GH-F8S 9 0.354 Refer to p.1152l for general precautions. • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference. C Model No. C(mm in) D(mm in) D GH-2S 15 0.591 10 0.394 GH-3S 20 0.787 15 0.591 GH-5S 25 0.984 20 0.787 GH-8S GH-F8S 40 1.575 26 1.024 Others • Do not use during the initial transient time (500 ms) after the power supply is switched on. • Do not use the sensor at places having intense vibrations, as this can cause malfunction. • When the sensor head is mounted on a moving base, stress should not be applied to the sensor cable joint. GL-6 Mutual interference Sensing range • The sensing range is specified for the standard sensing object. With a non-ferrous metal, the sensing range is obtained by multiplying with the correction coefficient specified below. Stress INDUCTIVE PROXIMITY SENSORS PRECAUTIONS FOR PROPER USE GXL GA-10/GH Stress GH-2S GH-3S GH-5S GH-8S GH-F8S 1 1 1 1 Stainless steel (SUS304) 0.68 approx. 0.55 approx. 0.69 approx. 0.64 approx. Brass 0.53 approx. 0.35 approx. 0.41 approx. 0.37 approx. Aluminum 0.51 approx. 0.33 approx. 0.39 approx. 0.32 approx. Iron Amplifier Built-in GL-18H/18HL GL-N12 Model No. Metal GL-8/8U Correction coefficient Part description GA-14 Cable lock lever Cable core inlet Shield wire inlet Operation indicator (Red) Operation mode switch Disconnection alarm indicator (Orange) Sensitivity adjuster Operation mode switch Screw for cable clamp GX-U/FU GA-15 Operation indicator (Red) Shield wire inlet Cable core inlet Sensitivity adjuster Disconnection alarm indicator (Orange) 2 3 Approach perpendicular to sensing axis Approach along sensing axis Set the operation • Turn the sensitivity adjuster 1 mode switch to NORM. fully counterclockwise. (Initial setting) (Minimum sensitivity) • Place the sensing object within the stable sensing range. • Turn the sensitivity adjuster clockwise and set it at the point Sensor Movement @ where the operation indicator axis head lights up. Sensing object • Place the sensing object within the stable sensing range. Sensing • Turn the sensitivity adjuster object clockwise, and set it at the Movement optimum sensing point b which axis Sensor is a little beyond the point @ head where the operation indicator lights up. GX-N Adjustment Sensitivity adjuster MIN MAX MIN GX Sensing condition A MAX MIN Amplifier-separated GA-10/GH Step Sensitivity adjustment A B MAX Select the operation mode as per your application. (NORM.: Normally open, INV.: Normally closed) Note: Use the accessory screwdriver to turn the adjuster slowly. Turning with excessive strength will cause damage to the adjuster. 761 INDUCTIVE PROXIMITY SENSORS GA-10/GH DIMENSIONS (Unit: mm in) GA-14 GA-15 Amplifier Assembly dimensions with attached amplifier mounting bracket GXL GL-6 5.8 0.228 31.5 1.240 GX-U/FU GL-18H/18HL GL-N12 Amplifier Built-in GL-8/8U 24.3 0.957 2 0.079 12.2 9 0.480 0.354 9 0.354 2 0.079 16 Suitable for 35 mm 1.378 in width DIN rail 0.630 Attached amplifier mounting bracket (MS-DIN-2) Seal 5.2 0.205 3.2 0.126 5.2 0.205 3.2 0.126 28.6 1.126 16 0.630 Note: The top view is without the cable and the cover. "1.8 "0.071 3.2 5.2 0.205 0.126 5 0.197 35 1.378 2 0.079 2 0.079 t1 t 0.039 27 1.063 GX-N Material: Cold rolled carbon steel (SPCC) Material: (Uni-chrome plated) MS-SS3 MS-SS5 Sensor head mounting bracket (Optional) MS-SS8 2-"3.5 "0.138 mounting holes GX F E 4 0.157 8 0.315 16 0.630 4 0.157 G Material: Nylon 66 Model No. D MS-SS3 MS-SS5 MS-SS8 16 0.630 18 0.709 20 0.787 E 9 0.354 10 0.394 11 0.433 F 6.3 0.248 8.3 0.327 10.3 0.406 G 4.9 0.193 6.1 0.240 6.5 0.256 Applicable sensor head model No. GH-3S GH-5S GH-8S 762 4.5 The cable output section 28.6 1.126 of the plug-in connector 0.177 type sensor differs. 2-"3.2 "0.126 holes 8.2 0.323 12.2 9 0.480 0.354 3.2 0.126 28.6 1.126 9 0.354 2 0.079 16 Suitable for 35 mm 1.378 in width DIN rail 0.630 Attached amplifier mounting bracket (MS-DIN-2) 5.2 0.205 3.2 0.126 5.2 0.205 16 0.630 Sensor head C Cable, 3 m 9.843 ft long 2-"3.2 "0.126 holes Symbol "7.6 " 0.299 4.2 0.165 B 7.5 0.295 4.2 0.165 4 0.157 Disconnection alarm indicator (Orange) 3 0.118 3 0.118 "4.2 "0.165 cable, 2 m 6.562 ft long 10 0.394 3.2 0.126 D 12.7 0.500 Cable core inlet 31.5 1.240 3 0.118 4.2 3.2 0.165 0.126 10 13 20.4 15.3 0.394 0.512 0.803 0.602 67 2.638 8 0.315 A 8.5 0.335 0.4 0.016 2.5 0.098 Shield wire inlet 10 0.394 GH-2S GH-3S GH-5S GH-8S GH-F8S 21.6 0.850 16 0.630 5.2 0.205 5.6 0.220 5 0.197 Note: The top view is without the cable and the cover. Amplifier mounting bracket (Accessory for amplifier) MS-DIN-2 Sensitivity adjuster "7.6 "0.299 4.2 0.165 3 0.118 The cable output section 4.5 28.6 of the plug-in connector 0.177 1.126 2-"3.2 "0.126 holes type sensor differs. 8.2 0.323 Disconnection alarm indicator (Orange) 3 0.118 3 0.118 "4.2 "0.165 cable, 2 m 6.562 ft long Operation mode switch Operation indicator (Red) 2-screw for cable clamp 5.6 0.220 4.2 3.2 9.1 0.165 0.126 3.8 0.358 0.150 15.3 20.4 23 0.803 0.602 0.906 67 2 2.638 8 0.079 0.315 10 0.394 GA-10/GH Amplifier-separated Assembly dimensions with attached amplifier mounting bracket Cable core inlet Cable lock lever Operation mode switch Shield wire inlet Sensitivity adjuster Operation indicator (Red) 5 0.197 Amplifier Model No. A B C GH-2S "2.8 "0.110 12 0.472 "1.6 "0.063 GH-3S "3.8 "0.150 15 0.591 "2.5 "0.098 GH-5S "5.4 "0.213 15 0.591 "2.5 "0.098 GH-8S "8.0 "0.315 15 0.591 "2.5 "0.098 GH-F8S "8.0 "0.315 15 0.591 "2.65 "0.104