Galaxy Lite Quick-start Guide

   EMBED


Share

Transcript

Galaxy 2-20 Quick-start Guide A full technical installation manual will be given to each installer at the training session. Additional manuals can be purchased from your distributor. NOTE: It is strongly recommended that any personnel installing a Galaxy 2 Series panel undertake appropriate training as supplied by Honeywell Security. This training is supplied free of charge and can be arranged by contacting Honeywell Security on: Tel: +44 (0) 1355 354 000 Email: [email protected] Setup Mains Supply Wiring In order to get the system up and running, mount the panel and connect and address all peripherals as described below, before finally powering the system. This product is not suitable for installation, maintenance or connection by the user. A competent, qualified engineer, with for example NSI approval, must carry out installation and maintenance. Peripheral Wiring Warning: A means of isolation from the mains supply must be provided within two metres of the control panel. Where live and neutral supplies can be identified, a fused spur with a 3A fuse must be fitted on the live circuit. Where live and neutral circuits cannot be readily identified, 3A fuses must be fitted to both circuits. The following peripherals can be connected to the panel: ƒ ƒ ƒ Mk7 LCD Keypad/Keyprox x 4 RIO/PSU x 1 RF Portal x 2. NOTE: The system must be wired in a daisy-chain configuration. Spur and star configurations must not be used. The recommended cable used to connect the RS485 (AB) line is twisted pair screened cable (Belden 8723 equivalent). However, for cable runs of less than 100m in normal environments, standard 4-core cable can be used. Panel Peripheral AUX+ AUX– A B + – A B Connect the wires to the mains terminal block in the panel as follows: • Blue (neutral) – connect to terminal N • Green/Yellow (earth) – connect to terminal E • Brown (live) – connect to terminal L First Boot-up After all the peripherals have been wired and addressed, apply power to the system. The keypads will configure and show the default banner display. Galaxy 20 V1.0 09:00 SAT 01 JAN RS485 Peripheral Wiring Default User Codes Peripheral Addressing Default User Code: 1234 Default Engineer Code: 112233 The address on most peripherals is set by either jumpers or a rotary switch. These must be set before the system is powered up. See the instructions with the peripheral for details. Menu Access Operation/Navigation Only valid codes can access the Galaxy Series 2 menu options. Type the code then press ent to access the menu. Data entry is via the 0-9 function keys and the * and # on the keypad. The A> and and , 0 Cancels the edit without saving changes Save string entry and exit Deletes character to left of cursor Deletes character at the cursor Code Tampers When enabled (see menu option 51.14 = Parameters. Lockouts), and 10 wrong codes are entered in succession, the device is locked. The lockout lasts for 2 minutes. After a further 10 wrong code entries, a tamper is logged and a signal is given. The device is again locked out for 2 minutes. Note: Wireless keyfobs and tags can still operate. Conversely, if a wrong tag is presented to a prox or an invalid wireless fob is activated for the same number of attempts, the prox and receiver devices are locked out, but the keypads still operate. If a combination of devices are used to enter 10 wrong codes, then all those devices are locked out for 2 minutes. 3 Panel Specifications Compliance and Approvals Physical The Galaxy 2 Series is compatible with the relevant parts of the following standards: • 99/05/EEC R&TTE Directive • EN50130-5:1998 Alarm systems. Environmental test methods Metal box - 1.2 mm steel Width: 400 mm Height: 255 mm Depth: 115 mm Weight: 4.2 kg (with mains transformer and PCB installed) Public Switched Telephone Network (PSTN) Approval The equipment has been approved to Council Decision 98/482/EC for Pan -European single terminal connection to the Public Switched Telephone Network (PSTN). However due to differences between the individual PSTNs provided in different countries the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. In the event of problems contact the equipment supplier in the first instance. The Galaxy 2 Series is designed to interwork with the following networks: Austria France Italy Norway Belgium Greece Liechtenstein Portugal United Kingdom Denmark Iceland Luxembourg Spain Finland Ireland The Netherlands Sweden -10oC to +40oC Operating temperature Electrical PSU Type A Mains Input: 230 V ac (+10%, -15%), 50 Hz Back-up Battery (not supplied): Up to 12 Ah 12 V Sealed Lead-Acid (metal encl.). Panel current: NOTE: Contact the equipment supplier before using the Galaxy 2 Series on any network not listed. 100mA HONEYWELL SECURITY LIMITED WARRANTY PSU Max total load (from AUX, Bell, Trigger and STU outputs) 600mA Max continuous ripple voltage 0.5V at max load Honeywell Security, and its divisions, subsidiaries and affiliates (“Seller”), 165 Eileen Way, Syosset, New York, 11791, warrants its products to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product. Seller’s obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labour, any product that is proved not in compliance with Seller’s specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other than Honeywell factory service. For warranty service, return product transportation prepaid to: Individual 12 V outputs Bell +12 V Both Aux+ combined Trigger Header +12 V 500 mA max 500 mA max 100 mA max Honeywell Security, 6 Aston Fields Road, Whitehouse Industrial Estate, Runcorn, Cheshire WA7 3DL Switched Outputs Trigger Header Outputs Bell Trigger Strobe Trigger Trig output Speaker Output Can sink 30 mA each Can sink 500 mA max Can sink 500 mA max Can sink 30 mA max 16 Ohms THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HERE OF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER’S OWN NEGLIGENCE OR FAULT. Fuses Mains Battery (F1) AUX (F2) Bell (F3) Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the products will in all cases provide adequate warning or protection. Customer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. 200 mA, 20 mm Anti-surge (IEC 127) 1 A, 20 mm Anti-surge 500 mA, 20 mm Anti-surge 500 mA, 20 mm Anti-surge CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER. EN50131 Compliance This product is suitable for use in systems designed to comply with PD6662: 2004 and prEN50131-1: 2004 Type: Control & Indicating Equipment Security Grade: 2 Environmental Class: II Alarm Transmission System: ATS 2 (options A, B, C & X) Power Supply Type: A This warranty replaces any previous warranties and is the only warranty made by Seller on this product. No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized. Honeywell Security 2 Redwood Crescent Peel Park Campus East Kilbride Glasgow G74 5PA UK IG1-0035 Rev 1 4