Preview only show first 10 pages with watermark. For full document please download

Gas 310 Eco Pro 5 (285) Technical Sheet

   EMBED


Share

Transcript

TECHNICAL SPECIFICATION SHEET Boiler Type : Issue Date : Gas 310 Eco Pro 285 September 2015 This is a quick reference specification sheet, full details can be found in the Gas 310 Eco Pro installation and Service guide via www.remeha.co.uk/documents MODEL : Gas 310 Eco Pro 285 Rated Output kW (80/60°c) : 51 - 261 Rated Output kW (50/30°c) : 279 Weight (dry) kg : 364 Overall Dim WxDxH mm : 716 x 1862 x 1500 ErP – Eco Design (4) Useful Efficiency Full load GCV % : 88.2 (4) Useful Efficiency Part load GCV % : 98.6 BURNER TYPE Pre mix Std Fuel Available : 3 Fuel Consumption M /h : Flame Protection : Ignition : HYDRAULICS Water Content ltrs : Resistance @ 11°C ∆t mbar : Resistance @ 20°C ∆t mbar : Nom Flow Rate @ 11° C ∆t l/s : Nom Flow Rate @ 20° C ∆t l/s : Min Flow Rate m3/h : Condensate Outlet mm I/D : FLUE/AIR INLET Flue diameter mm I/D : Air inlet diameter mm I/D : Residual Fan Duty Pa : ELECTRICAL Power Supply : Power Consumption W : Modulating input V dc : Start Current amps : CONTROL OPERATION Standard : Optional : Main Options Contact Sales Dept for more details No of SECTIONS : 5 (1) SBEM Seasonal Efficiency % GCV : (2) Efficiency - Full Load 100 % NCV : (3) Efficiency – Part Load 30% NCV : ( ) Stand-by Heat Loss % : * 96.62 98 109.2 0.21 Sound Power Level LWA indoors dB : 69 Natural Gas 28.1 (Max) Ionisation Electronic Gas Connection size BSP : ( ) Acoustic level dB(A) at 1 metre : ** NOx (Dry, 0% O₂) Mg/kWh EN483 EN15420 : Min/Max Gas pressure mbar : 2” (F) 61 33 17 - 30 49 374 113 5.68 3.12 3.4 32 Standard = conventional 250 250 130 Connection Size Flanged : (#) Std Operating Temp °C : Max Operating Temp °C : High Limit Set Point °C : Max operating pressure bar : Min operating pressure bar : NW 80 20 - 90 90 110 7 0.8 Mass flue gas flow rate kg/hr : Flue Gas Temperature @ 80/60 °C : 91 - 448 30 - 80 230v – 1ph – 50hz 6 - 279 0 -10 4 Fuse Rating amps : Controls Voltage : Insulation Class IP : Run Current amps : 10 24 (max 4va) X1B 1.4 On/Off 0-10v dc Manual o/ride Open Therm Modulating (20 - 100%, avg.) High limit protection Safety interlocks Low water protection Hours run indication Volt free common alarm Boiler run indication Optimising / Compensators > For multiple and single boiler Second return > 65mm Flanged 80mm PN16 Gas leak Detection > Option fitted to gas valve Water Pressure Switch > System pressure Air Inlet Filter > Connects to boiler air supply (¹) In accordance with the Non Domestic Building Services Compliance Guide 2013 Edition – For use in England (²) @ 80/60°C Nett (EN 92/42) (³) @ 30°C Nett (EN 92/42) (4) In accordance with EU 813 & 814 / 2013 Eco design Regulations ° (*)(EN15420) @ 30 c ΔT = Boiler temperature – Ambient temperature (without heat exchanger insulation kit) (**) Maximum for room sealed operation (#) Flow 80mm Return 65mm both flanged NW 80 DIN 2576 – (PN16) Ours is a policy of continuous development, we therefore reserve the right to alter specifications without prior notification. Remeha Commercial accept no liability for any loss or damage rising from any errors or omissions that may be inadvertently contained in this specification sheet. Sept V2 