Dear customers, We would like to congratulate you on buying our product – GSM Gate GB 102. This way you obtained high-class and technically highly modern product. GSM Gate by LEVEL provides possibility of significant phone costs savings as well as installation of phone line even in place where it otherwise would not be possible Before connection of GB 102 and its setting into operation, please, read carefully these instructions manual. It will not only introduce you correct installation and handling of this product but at the same time will help you fully utilize all its technical potentialities. Allowed use GSM Gate GB 102 allows connection of extension exchange input (free position for direct line) or phone device to phone line connector. ATTENTION: GB 102 is source of phone line therefore never connect either direct or extension phone lines to connector. ATTENTION: GSM Gates are not subject of homologation by ČTÚ (Czech Telecommunication Office). Entrepreneur is therefore obliged to ensure that calls from public fixed line network are not connected through them (only internal – extension – calls are allowed). Power supply of the product can be carried out by network adapter delivered with product or by backup source 12 V DC. Product is meant only for indoor use, not outdoor. It is necessary to avoid all contacts of device with moisture. Another than above stated use can cause incorrect function or damage of product. This is combined with danger – e.g. short circuit, fire or injury by electric current. It is not possible to make calls during current outage. Therefore we recommend connecting of network supply from backed up power supply UPS or connecting of backup power supply from battery 12 V. Programmed configuration will be saved in memory – type EEPROM – for arbitrarily long time during current outage.
2
TABLE OF CONTENTS: 1.
Description and Usage of Product.........................................................................4 Contents of Delivery...............................................................................................4 2. Safety Instructions..................................................................................................4 3. Installation ...............................................................................................................5 3.1. GSM Gate Assembly..............................................................................................5 3.2. Connection of Cables and Antenna........................................................................5 3.3. Inserting of SIM Cards ...........................................................................................5 3.4. Indication by LED ...................................................................................................6 4. Configuring..............................................................................................................6 4.1. Configuring gateway from PC ................................................................................6 4.2. Configuring gateway from PC connected over remote access...............................7 4.3. Configuring via Phone Line ....................................................................................7 4.4. Configuring and Operating by SMS Messages ......................................................7 5. Control Instructions................................................................................................8 5.1. PIN in GSM Gate GB 102 ......................................................................................8 5.2. Set-up of Direction Adding .....................................................................................9 5.3. Set-up of Allowed Directions ..................................................................................9 5.4. Code for Disallowed Directions ............................................................................10 5.5. Set-up of Delay before Dial ..................................................................................11 5.6. Set-up of Waiting Time for Dial ............................................................................11 5.7. Set-up of Number Control ....................................................................................11 5.8. Set-up of Number of Digits after which Number Is Sent.......................................11 5.9. Set-up of Dial Tone Type .....................................................................................12 5.10. Set-up of Programming Symbol # or *..................................................................12 5.11. Set-up of Tariffs....................................................................................................12 5.12. Number for Information SMS Messages ..............................................................13 5.13. Set-up of Number for Monthly Upkeep Calling.....................................................13 5.14. ALARM SMS Messages and Set-up of A-numbers for SMS Sending..................13 5.15. ALARM SMS Messages and Set-up of B-numbers for SMS Sending..................14 5.16. Set-up of Numbers for ALARM Calling.................................................................14 5.17. Set-up of Text of ALARM SMS Messages ...........................................................14 5.18. Set-up of Logical Level of Outputs .......................................................................15 5.19. Set-up of Sensitivity of Audio Input .....................................................................15 5.20. Set-up of Volume of Audio Output.......................................................................15 5.21. Virtual Tie Line .....................................................................................................15 5.22. RESET of Gate and Time Counters .....................................................................17 5.23. Initialization of Gate to Initial Set-up from Production...........................................18 6. List of Programming Commands.........................................................................19 6.1. Basic Programming Commands...........................................................................19 6.2. Additional Programming Commands....................................................................21 7. Utility software for PC...........................................................................................22 7.1. Installation. ...........................................................................................................22 7.2. Control Panel .......................................................................................................22 8. Basic Technical Parameters.................................................................................23 GUARANTEE CERTIFICATE ............................................................................................24 GUARANTEE CONDITIONS .............................................................................................25 1.1.
3
1.
Description and Usage of Product The GB 102 GSM Gate is a two-way converter of fixed phone line for calls to cell phone GSM network. At the same time device allows sending of prepared SMS messages (only GB 102 x2x) on the basis of changes in voltage on inputs and evaluation of incoming SMS messages for set-up of outputs.
GB 102 226
Built-in unit (alarm inputs, PC connect., tarif. 12 kHz) Built-in unit (alarm inputs, PC connect., tarif. 16 kHz) GSM Gate (tarif. 12 kHz) GSM Gate (tarif. 16 kHz) GSM Gate (alarm inputs, PC connect., tarif. 12 kHz) GSM Gate (alarm inputs, PC connect., tarif. 16 kHz) Power adapter 12 V DC Telephone cable 2 m GSM antenna 3 dB Convertor with cables, software for configuration Mounting set - wall plugs, screws and drill template Conector micro Fit, 6× grip User Guide
GB 102 222
GB 102 122 GB 102 126 GB 102 212 GB 102 216 GB 102 222 GB 102 226 SA 012 600 CB 111 015 ED 001 001 ED 102 001
GB 102 216
Component description
GB 102 212
Part no.
GB 102 126
GB 102 122
1.1. Contents of Delivery
● ● ● ● ● ○
○
○ ○
○ ○
● ●
● ●
● ● ●
● ● ●
●
●
●
●
● ● ● ○ ● ● ●
● ● ● ● ○ ● ● ●
Note: (●) included in the set (○) accessory can be used with the given type of product 2.
Safety Instructions GSM Gates by LEVEL are conformable with technical standards for operation in our mains. Power source with voltage 10,6-16 V DC fitted with connector with positive central contact shall be used for power supply. Dimension for current 600 mA – maximum power take-off during call, securing – safety-fuse T 1A. Device must be disconnected from all power sources before maintenance or exchange of parts or filled boards. No fluids must enter the device. Danger of fire or injury by electric current impend. Do not place device into rooms with high temperatures, strong vibrations or high humidity. In case you moved device from cool to warm room do not set it into operation immediately. Let device warm up to temperature of room. Wait until condensed water evaporates. 4
3. Installation 3.1. GSM Gate Assembly GSM Gates by LEVEL are designed for operation in dry places. During assembly avoid hot places and places where device would be exposed to direct solar radiation or places close to heating elements. Do not place GSM Gate or antenna mast close to phone exchange or other electronic device or line. Due to high-frequency electromagnetic field these devices could be interfered. Choose such a place where interference is minimal. Due to interference it is also not advisable to operate the device close to other power or high-frequency devices. Before starting assembling verify there is sufficient level of signal required by GSM network in selected place. Please place the rod antenna ED 001 001 as for as possible from the GB 102 GSM Gateway and place the antenna cable away from the telephone line cable to avoid interferences. 3.2. Connection of Cables and Antenna Phone cable with end US RJ shall be used for connection of phone line. Length of connecting cable for installation should not be shorter than 5 meters so that it is possible to place GSM Gate and antenna in sufficient distance from exchange. However, phone cable should not be longer than 200 m. Connection cables for signals, which operate SMS messages, shall be connected to connector micro Fit according to recommended connections – see ch. 5.14. For connection with PC use a serial cable and converter with cable equipped with micro Fit connector. There is 12V DC power connected on pins + and ┴ of micro Fit connector designed for power input of the converter – maximum load capability is 200 mA. External antenna, which is a part of equipment, shall be screwed into connector for antenna. In case signal is weak use more sensitive antenna. Network adapter shall be connected at first with GSM Gate - into connector marked 12 VDC - and then plugged into socket. 3.3. Inserting of SIM Cards SIM card is inserted into slot next to the GSM antenna. There is a yellow release button next to the slot. Use suitable tool for releasing the slot. Do not try to release the slot by force. Insert the SIM card into the plate and push the slot back in with the SIM card connector facing up. 5
To ensure the GSM gate cooperates with SIM card correctly it is necessary to set the same PIN number in GB 102 configuration as on the SIM card or set no PIN code blocking on the SIM. 3.4. Indication by LED Indication LEDs on GB 102 indicate basic operational states: PWR– power supply status Permanently on - Indicates connected power input GSM –GSM module status Blinking 0,5 s / 0,5 s - Connecting to the GSM network Blinking 0,2 s / 2 s - Indicates GSM network connected Permanently on - Communication in progress STATUS – phone line status Permanently on - Line is picked up Blinking quickly - Dialing Blinking slowly - Ringing 4.
Configuring Number of functions and parameters, which allow maximum adjustment of gate GB 102 to environment and user’s requirements, can be set by programming. Parameter configuration change can be performed using: Control Panel software connected via serial line from PC Control Panel software connected via GSM remote access A regular phone using tone dialing SMS messages sent from mobile phone 4.1. Configuring gateway from PC 1. 2.
3. 4.
Install program Control Panel from CD, which is part of delivery, in your PC. Connect GB 102 to the computer using serial port and reduction cable, run the Control Panel software. Choose the used communication port in Communication Settings. You can read actual configuration from GB 102, edit all parameters and save configurations on disc. Configuration becomes valid immediately after sending into GB 102. If change of PIN was part of configuration prove login of GB 102 in network by switching-off and on. 6
4.2. Configuring gateway from PC connected over remote access To use the remote access possibility it is necessary to have the data services activated on the SIM cart used in the GB 102 and the remote access connection must be enabled in configuration of GB 102. It is recommended to use a PC GSM modem for the remote access. Connection parameters for remote access can be found in Control Panel - Settings Communication Settings - Remote Access. Connect to the GB 102 using the GSM network and continue in changing configuration using the Control Panel. 4.3. Configuring via Phone Line Configuring GB 102 via phone line is performed by dialing numbers on a phone with tone dialing. 1.
2.
3. 4.
5.
Connect the phone to the GB 102 – pick up the receiver, in case of need when using a PBX dial the access code of the extension line connected to the GB 102. You should hear the dial tone. Dial #pppp#, where pppp are four digits of gate PIN. PIN is set 1234 from production. After entering correct PIN you will hear tone configuring tone (·· ·· ·· ). Enter particular setting parameters. Dial 4 digits of instruction followed by value of parameter for particular instruction. End entering of instruction by dialing #. Time control is 1 minute after last dial. After entering correct instruction you will hear tone “Configuring” again and another instruction can be entered. Configuring mode will be exited by hang-up of receiver.
If you enter invalid configuration command you will hear the busy tone. In this case continue the settings by entering the command again or end the settings mode by hanging up. If valid commands were entered before, the new settings will be saved. If there is the programming symbol “*” set instead of “#” then use “*” in all commands. 4.4. Configuring and Operating by SMS Messages Incoming SMS messages are processed - command messages are executed and all others can be ether deleted or forwarded to a phone number preset in configuration. 7
SMS messages coming to phone number of SIM card are decoded. Control messages are immediately realized. General format of control SMS message is following:
XXppppINSTRUCTION1parameter1INSTRUCTION2parameter2… XX pppp INSTRUCTION
Opening digits – two capital letters X. Actual PIN of gate. Key word of instruction in SMS message – capital or small letters do not matter.
Space. Set-up value of instruction No.1. End of instruction sequence shall be carried out either by ending of SMS message or space.
Parameter1
Space or enter in SMS message can be followed by other key words of instructions and their parameters up to maximum length of SMS message, tm. up to 160 characters. Message about performing of an instruction is always sent back to sender’s cell phone. Parameter NOTIFYSMS means that the preset number will receive all reset messages and low prepaid credit reports. If parameter INFOSMS is set messages about changes in set-up, messages about reset and information about time of operation are sent to this number. Deleting of numeral or text data is carried out by substitution of parameter value by point . or quotes “”. 5.
Control Instructions 5.1. PIN in GSM Gate GB 102 In case the inserted SIM cards are protected by PIN number it is necessary to verify that the PIN SIM entered in the configuration software are the same as the PINs set on the SIM cards. It is also possible to use SIM cards with no PIN protection - in such case it is not important what PIN(s) are configured in the GSM gate. PIN of GSM Gate is used as access code for programming by SMS messages or by phone. PIN = pppp.
8
Dial Command 0000xxxx#
SMS Command PIN xxxx
Default 1234
Change of PIN SIM
Where xxxx are four digits of new PINs. Example: Original PIN of GSM gate is 1234. PIN of SIM card, which will be used in GSM gate is 4321. ● Pick up handset and wait for dialing tone. ● Enter programming mode by dialing #1234#. ● After hearing the programming tone dial 00004321#. ● Hang up. It is not possible to program gate by SMS messages if PIN SIM in gate is not conformable to PIN of SIM card. Login of gate in GSM network is then not carried out. This is e.g. state after initialization. For conformity of PINs choose another way of programming. 5.2. Set-up of Direction Adding Some exchanges do not repeat pre-selection of number dialed before interconnection when connecting call to transmitter with GSM gate. This function allows reconstruction of originally dialed number by adding of removed preselection. Dial Command 0100x#
SMS Command PDIR x
Default Not activated from production.
Where x is 0 to 7 digits, which shall be added. Removal of values by phone is carried out by instruction 0100# or by SMS message PDIR . (Point represents data) or PDIR ““. 5.3. Set-up of Allowed Directions If you want to avoid connection of useless calls (which would have higher tariffs than when connected through fixed line) through GSM gate set required values of pre-selections as allowed directions. Other calls, e.g. calls into fixed local or toll phone network, will not be connected through GSM gate. Dial Command 0201x# 0202x# 0203x# 0204x# 0205x# 0206x#
SMS Command ADIR1 x ADIR2 x ADIR3 x ADIR4 x ADIR5 x ADIR6 x 9
Default 1 2 3 4 5 6
0207x# 0208x# 0209x# 0210x# 0211x# 0212x# 0213x# 0214x# 0215x# 0216x#
ADIR7 x ADIR8 x ADIR9 x ADIR10 x ADIR11 x ADIR12 x ADIR13 x ADIR14 x ADIR15 x ADIR16 x
7 8 9 0
Where x is 1 to 7-digit-number of pre-selection. Removal of values is carried out by instruction 0201#, 0202#, etc. or by SMS message ADIR1 . (point represents data) or ADIR ““. ATTENTION! ● If you remove all values GSM gate will not connect any calls except numbers, which begin with code for unblocking, if it is set. After end of dialing of number you will hear busy tone. ● With standard manufacturer settings the GSM gateway is enabled to call all numbers without limitations ● If you use function of automatic switch-over to second SIM card according to dialed number (parameter SIMDIR), set numbers of pre-selections from longest to shortest. Priority of evaluation goes from above. 5.4. Code for Disallowed Directions Code for disallowed directions, dialed in front of phone number, allows dialing of numbers, which are not in list of allowed directions. When dialing number into gate, calling is allowed by dialing of correct code in front of phone number. Gate then removes code and sends only phone number in GSM. We recommend to use in applications where gate is accessible from public network after preselection. Dial Command 0300x#
SMS Command CDIR x
Default Not activated from production.
Where x is 0 to 7 digits, which shall be removed. Removal of values is carried out by instruction 0300# or by SMS message CDIR . (point represents parameter). Example: prefixes.
If you need to enter the unblocking code (1234) for disallowed
10
● Enter the phone programming mode #pppp# (see Chapter. 4.1.) ● Dial 03001234# and hang up the phone or send a command SMS message (as described in Chapter 4.2.) XXpppp CDIR 1234 From this moment the gateway will start connecting all calls to numbers starting 1234 just like to other allowed prefixes while it will remove the 1234 code and send dialing of the rest of the number into GSM. 5.5. Set-up of Delay before Dial After occupation of transmitter some exchanges cause glimmer of line, which could be evaluated as number by GSM gate. This function allows setting of delay after moment of pick-up. During this delay situation on line will be ignored. Dial Command 0600x#
SMS Command DELAY x
Default 3, tm. 0,3s set from production
Where x is number in range from 0 to 99 and means time in tenths of seconds, tm. 0,0-9,9 s. 5.6. Set-up of Waiting Time for Dial After picking up GSM gate gives you dialing tone, which notifies you about possibility of dialing of number. After set time period dialing tone changes to busy tone and reading of dialed phone number is terminated. Dial Command 0700x#
SMS Command TLINE x
Default 60, tm. 60s set from production
Where x is number in range from 10 to 120 and means time in seconds, tm. 10-120 s. 5.7. Set-up of Number Control After dialing of last digit of number GSM gate waits for set time in case further digit is dialed. After expiry of this time reading of dial is terminated and dial is sent to GSM. Dial Command 0800x#...
SMS Command TDIAL x
Default 4, tm. 4s set from production
Where x is number in range from 1 to 20 and means time in tenths of seconds, tm.1-20 s. 5.8. Set-up of Number of Digits after which Number Is Sent If allowed directions of GSM gate are only cell phone numbers, that always have 11
maximum of 9 digits, it would make sense to set 9 as maximum number of digits. th After selection of the 9 digit, dialing of number starts immediately without waiting for control. Dial Command 0900x#...
SMS Command LDIAL x
Default 24 set from production
Where x is number in range from 3 to 24 and means maximum number of digits. 5.9. Set-up of Dial Tone Type Instruction by Phone 1000x#...
SMS Instruction TONE1 x
Pre-set 2 set from production
Where x is number from 0 to 4 and specifies type of dial tone: x= 0 – without dialing tone x= 1 – permanent dial tone x= 2 – dialing tone (· – · – · – ) x= 3 – dialing tone (·· – ·· – ·· – ) x= 4 – dialing tone (··· – ··· – ··· – ) 5.10. Set-up of Programming Symbol # or * If symbol # is used by extension exchange for any service concurrent with functions of GSM gate it is possible to set that symbol * is used exclusively in all instructions instead of symbol #. Dial Command 1100x#...
SMS Command FLAG x
Default 0, tm. # is set from production
Where x is 0 or 1 where 0 means usage of # and 1 means usage of *. 5.11. Set-up of Tariffs GB 102 enables reading tariff information about phone calls using tariff pulses 16 kHz (12 kHz at the GB 102 xx2 model) or by changing line polarity. Dial Command 1200x#...
SMS Command TARIF x
Default 0, tm. no tariff set from production
Where x is 0 to 63 x= 0 No transmission x= 1-60 Periodical impulse 16 kHz in interval from 1 to 60 s x= 61 Change of polarity when picked up by called party x= 63 16 kHz impulse when picked up by called party Test mode of tariff information can be enabled using parameter 100010# (TONE 10) as described in Chapter 6.1. 12
5.12. Number for Information SMS Messages GB 102 allows automatic sending of information about changes in configuration, operation time and about RESET. Information is sent as SMS message to set cell phone number if this number is entered in following way: Dial Command 2000x#...
SMS Command NOTYFISMS x
Default Not activated from production
Where x is 1 to 20 digits of cell phone number. 5.13. Set-up of Number for Monthly Upkeep Calling Sometimes a GSM operator requires to place a paid outgoing call from a SIM card with prepaid credit (e. g. every three months) in order to keep the credit alive. So that user, which uses GB 102 for protection of properties, does not have to think of this matter it is possible to enter number, which gate automatically calls each month of operation, in GB 102. Dial Command 2100x#...
SMS Command MCALL x
Default Not activated from production
Where x is 1 to 20 digits of number. Removal of values is carried out by instruction 2100# or by SMS message MCALL . (point represents data). If you want to use this service it is recommended to set number of your fax or number of time information. It is not recommended to set your cell phone number because GB 102 does not use real time and call can come during night. 5.14.
ALARM SMS Messages and Set-up of A-numbers for SMS Sending
5 input / output signals are taken out on connector micro Fit of GB 102 (only GB 102 x2x). One of five prepared texts can be sent in form of SMS message to two cell phone numbers. It is possible to enter A and B numbers for sending SMS message to each of inputs No. 1-5. Instruction by Phone 220xy#
SMS Instruction SMSNOAx y
Pre-set Not activated in production
Where x is number of input from 1 to 5. Where y is 1 to 20 digits of cell phone number. Numbers can be entered both in national and international format (606445566 or +420606445566).
13
Recommended linkage of input, example for input No. 1.
(Drawing of connector on GB 102) Since output works at the same time also as input set-up of logical level 0 on output avoids activation of sending SMS message from particular input. In case call is just made through GB 102 it is terminated immediately and all alarm actions are carried out. 5.15.
ALARM SMS Messages and Set-up of B-numbers for SMS Sending Instruction by Phone 220xy#
SMS Instruction SMSNOBx y
Pre-set Not activated in production
Where x is number of input from 1 to 5. Where y is 1 to 20 digits of cell phone number. 5.16.
Set-up of Numbers for ALARM Calling
When one of the inputs 1-5 is activated (only GB 102 x2x), the preset phone number will be dialed and the called party will hear warning tone from GB 102 first three DTMF tones followed by number of further tones, that number is determined by number of the activated input.. Instruction by Phone 240xy#...
SMS Instruction ALARMCALLx y
Pre-set Not activated in production
Where x is number of input No. 1-5. Where y is 1 to 20 digits of number to any phone. 5.17.
Set-up of Text of ALARM SMS Messages
Set text of message, which is sent in case of input activation, is assigned to particular input No. 1-5 (only GB 102 x2x). Text can be changed by following instruction: Instruction by Phone 250xtext#...
SMS Instruction SMSTXTx “text“
14
Pre-set Set from production: ALARMx
Where x is number of input No. 1-5. Where text is entered as numeric values according to ASCII table through phone line, in SMS message text is closed into quotes. 5.18.
Set-up of Logical Level of Outputs
Each input No. 1-5 is also output at the same time (only GB 102 x2x). Value of logical level of particular output can be changed in following way: Instruction by Phone 260xy#...
SMS Instruction IOx y
Pre-set log. 1 for all outputs set from production
Where x is number of input No. 1-5. Where y is required logical level of 0 or 1. Recommended linkage of outputs with galvanic detachment, example for output No. 1:
(Drawing of connector on GB 102) 5.19.
Set-up of Sensitivity of Audio Input Instruction by Phone 2701x#...
SMS Instruction AUDIOINP x
Pre-set Set from production: 64
Where x is number of 0-100 (0=min, 100=max) 5.20.
Set-up of Volume of Audio Output Instruction by Phone 2702x#...
SMS Instruction AUDIOOUT x
Pre-set Set from production: 64
Where x is number of 0-100 (0=min, 100=max) 5.21. Virtual Tie Line The GB 102 device enables to create a virtual tie line connection between two PBXs using the GSM network. Clients using one PBX then can call remote PBX users using the short-code dialing. 15
Example of Creating a Virtual Tie Line: PBX “A” user dials 7123, where 7 is the direction towards the remote PBX “B” and 123 is the extension number. PBX “A” directs the phone call via the connected GSM gateway “A”. The GSM gateway “A” receives the dial 7123, replaces the digit 7 for real number of GSM gateway “B” (e.g. 777 666 555) and dials the number. GSM gateway “B” rings the PBX “B” which will pick-up the phone call and add the DISA prefix. After PBX “B” answers the call, the GSM gate “A” will continue dialing extension 123 (using DTMF codes). In moment the extension 123 on PBX “B” answers the phone call it will be connected with user of the PBX “A” who initialized the phone call. Enabling – Disabling the Feature Dial Command 2800x#...
SMS Command TIEENABLE x
Default Preset from production to 0
Where x=1 enables the virtual tie line feature and x=0 disables the feature. Delay of Additional DTMF Transmission This parameter determines the delay before the additional DTMF selection starts after the phone call is answered. Additional DTMF selection enables dialing an extension number from the incoming call - usually using the DISA selection. Dial Command 2900x#...
SMS Command TIEDELAYx
Default Preset from production to 5 (×0,1 s)
Where x is a number between 0 and 255 which determines the length of delay in tenths of a second. DTMF Pulse Width This parameter determined length of DTMF pulse of the additional selection. Dial Command 3000x#...
SMS Command TIEWIDTH x
Default Preset from production to 4 (×0,1 s)
Where x is a number between 3 and 10 which determines the length of the pulse in a tenths of a second. Enter Prefix Dial This is the initial number of the short-code dialing coming to the gateway which will be replaced by phone number of the remote PBX. The gateway can remember up to 5 different numbers for 5 different phone numbers of remote PBX’s. 16
Dial Command 310xy#...
SMS Command TIEENTERx y
Default Not preset from production
Where x is number of position 1 to 5. Where y is up to 16 digits of enter prefix dial selection. Result Dial This is the phone number of the remote PBX which will replace the enter prefix dial number. Dial Command 320xy#...
SMS Command TIERESULTx y
Default Not preset from production
Where x is number of position 1 to 5. Where y is up to 16 digits of result dial selection. Connection Mode Mode 0 (substitution dial) will replace the enter prefix dial of short-code selection, coming to the gateway, with phone number of the result dial selection and will complete the whole selection with the rest of the short-code selection. This mode is suitable for directing phone calls to PBX’s with ISDN dialing-in. Mode 1 (additional dial) will replace the enter prefix dial of short-code selection, coming to the gateway, with phone number of the result dial selection and after the phone call is answered will carry out dialing of the rest of the short-code selection using DTMF pulses. This mode is suitable for directing phone calls to PBX’s with DISA dialing-in. Dial Command 330xy#...
SMS Command TIEMODEx y
Default Preset from production to 0
Where x is number of position 1 to 5. Where y= 0 for mode 0 and y=1 for mode 1. 5.22. RESET of Gate and Time Counters It is possible to carry out remote RESET of GB 102 using SMS message. Action is equivalent to switch-on of charging tm. start-up of program, switch-off and on of GSM module and login in network. Dial Command
SMS Command RESET
Default
SMS command message should look like this: XXpppp RESET (see Chapter 4.2.)
17
5.23. Initialization of Gate to Initial Set-up from Production. Remote initialization of GB 102 can be carried out using SMS message. All adjustable parameters except PIN numbers and blocking of SIM card are set to initial values set from production. At the same time RESET is carried out. Implementation of INIT makes GSM Gate during 20 sec. If you are doing this implementation through the phone, hang up after return dialing tone in the phone receiver. Dial Command 3400#
SMS Command INIT
Default
Hardware initialization (only GB 102 x2x): ● ● ● ● ●
disconnect the GB 102 power supply connect PIN „I“ with „┴“ of the micro Fit connector connect the GB 102 unit to power supply LED indicating PWR will blink 3 times remove connection of PINs - the gateway will go into default settings at 20 s
18
6.
List of Programming Commands Switch-over into programming mode is carried out by dialing #pppp# on phone line. Code XXpppp must forgo instructions in each control SMS message where pppp is PIN of the GSM gateway. 6.1.
Basic Programming Commands By phone #pppp# …
SMS Command XXpppp …
Range
PIN for SIM – main PIN
0001pppp#
PIN1 pppp
4 digits of PIN
Adding of direction
0100x #
PDIR x
x= . or 1-7 digits
0201x # 0202x # 0203x # 0204x # 0205x # 0206x # 0207x # 0208x # 0209x # 0210x # 0211x # 0212x # 0213x # 0214x # 0215x # 0216x #
ADIR1 x ADIR2 x ADIR3 x ADIR4 x ADIR5 x ADIR6 x ADIR7 x ADIR8 x ADIR9 x ADIR10 x ADIR11 x ADIR12 x ADIR13 x ADIR14 x ADIR15 x ADIR16 x
Code for disallowed directions
0300x #
CDIR x
x= . or 1-7 digits
Ringing after switch-on
0500x #
IRING x
x= 0-20 s/10
8 s /10
Delay before dial
0600x #
DELAY x
x= 0-20 s/10
3 s /10
Waiting for dial
0700x #
TLINE x
x= 10-99 s
60 s
Time of number control
0800x #
TDIAL x
x= 1-20 s
4s
Number of digits
0900x #
LDIAL x
x= 3-24 digits
24
2
Instruction
Allowed directions
x= 1-7 digits or x= . clears out parameter value
Initial values 1234 1 2 3 4 5 6 7 8 9 0 -
Dialing tone of SIM
1000x #
TONE x
x= 0 – without tone x= 1 – permanent t. x= 2 – tone • – x= 3 – tone • • – x= 4 – tone • • • – x= 10 – test tarif.
Programming symbol
1100x #
FLAG x
x= 0..#, x= 1.. *
0
TARIFF x
x= 0 - switched-off x= 1-60 int. of pulse 16kHz x= 61 - rev. polarity x= 63 - 1 p. 16kHz
0
Set-up of tariffs
1200x #
19
SMS message
1500x #
SMSMODE x
x= 0 - delete SMS x= 2 - another no.
0
Phone number for resending SMS
1501x #
SMSREROUTETOx
x= 1-20 digits
-
Number for info. SMS
2000x #
NOTIFYSMS x
x=. or 1-20 digits
-
2100x #
MCALL x
x=. or 1-20 digits
-
220xy #
SMSNOAx y
-
Number SMS ALARM B
230xy #
SMSNOBx y
Numbers for ALARM calling Set-up of SMS message texts
240xy #
ALARMCALLx y
250xy #
SMSTXTx “y“
Set-up of outputs
260xy #
IOx y
Number for monthly calling for SIM no. 1 Number SMS ALARM A
Setting audio in
2701x #
AUDIOINP x
x= input 1-5 y=. or 1-20 digits x= input 1-5 y=. or 1-20 digits x= input 1-5 y=. or 1-20 digits x= input 1-5 y= text in SMS text is in ““ x = input 1-5 y = 0 or 1 x= 0-100
Setting audio out
2702x #
AUDIOOUT x
x= 0-100
64
Virtual tie line - DTMF pulse width
3000x #
TIEWIDTH x
x= 3-10 (× 0,1 s)
4
Virtual tie line - enter prefix dial
310x y #
TIEENTERx y
x= 1-5 position y= 1-16 digits
-
Virtual tie line - result dial
320x y #
TIERESULTx y
x= 1-5 position y= 1-16 digits
-
Virtual tie line - connection mode
330x y #
TIEMODEx y
x= 1-5 position y= 0 or 1
0
Reset
Alarmx
all 1 64
RESET
-
Initialization
3400 #
INIT
Prefix transcript 00 to +
7000x #
Nocvt00 x
x= 0 - alloved x= 1 - denided
0
Numbers can be entered in national format – e.g. 606445566 but also in international format – e.g. +420606445566. Numbers in international format cannot be entered through phone line.
20
6.2.
Additional Programming Commands
Additional programming commands can be entered using SMS commands (details in Chapter 4.2.)
Description
Command
Range
Defa ult
Complete information about device, name, PRODUCT serial number, hardware and software version Type of device
PRONAME
Serial number of device
PRONUM
Software version (firmware)
SWVER
Hardware version
HWVER
Complete information about GSM network connection
GSM
GSM operator name
OPERATOR
Prepaid credit for each SIM card
CREDIT
GSM cell ID number used by device
CELLID
GSM signal strength
SIGNAL
Complete information about binary inputs and outputs status
IOS
Find out prepaid credit for each SIM card
CREDITMODE x
x= 0 do not find out x= 1 find out credit on SIM x= 2 find out credit by USSD command
0
USSD command for getting the prepaid credit value for each SIM
CREDITUSSD x
x= 0-8 symbols USSD command
-
Lower limit of prepaid credit, reaching this value will result in sending a warning SMS
CREDITLOW x
x= 0-1000000
0
Text of SMS sent during the device reset
RESETTXT x
x= 0-100 characters in SMS is x in“”
-
Text of SMS sent when lower limit of prepaid credit is reached
CREDITTXT x
x= 0-100 char. in SMS is x in“”
-
21
0= min. 36= max
7.
Utility software for PC. Part of the delivery is now an installation CD containing installation file with Control Panel software for Windows (only GB 102 x2x). 7.1.
Installation. Insert installation CD into your CD drive and wait until the installation starts automatically, you can also run the setup.exe file on the CD. Please follow the installation guide dialog.
7.2.
Control Panel Program answers the purpose of comfortable and transparent configuration of GB 102 and allows the following functions: Edit all parameters of GB 102. Opening / saving configuration from file / to file and from GB 102 / into GB 102. Remote control to the GB 102 configuration using the GSM network connection Display the level of GSM signal.
22
8.
Basic Technical Parameters. Line GB 102 Dialing of number Line voltage Ringing Tones Impulse 16 kHz Connecting connector SMS inputs micro Fit No. 1-5 SMS outputs micro Fit No. 1-5 micro Fit + GSM network GSM SIM card Device Power supply voltage Power take-off Size Weight Operational temperatures
Dial pulse or tone dialing 24 V 48 Vef. 50 Hz - 1 s / 4 s 425 Hz 16000 Hz ±0,1 %, 35 ms, min. 150 mV RJ 11 log. 0 log. 1
0-0,5 V 2-5 V
log. 0 max. 0,4 V max. Iz= 5 mA log. 1 2-3,3 V at Iz= 0,1mA 12 V DC max. load 200 mA
900 MHz / 1800 MHz Plug-in 10,5-16 V ss (network adapter 12 V / 600 mA) Max. 6 W, at rest 1,5 W 72 × 120 × 29 mm 240 g from +5 to +40 °C
23
GUARANTEE CERTIFICATE
Product name:
Type :
Production number:
Date of sale:
Seller: Address, Phone, Stamp:
Date of Receipt
Date of Shipping
Description of Defect
24
Signature:
GUARANTEE CONDITIONS Length of guarantee period is 24 months from the date of sale. Guarantee applies only to goods registered or identified by company LEVEL. Guarantee repair will be carried out at latest within 10 working days after receipt of defective goods by company LEVEL provided that spare part is disposable in store. If it is not possible alternative solution will be offered to user for the time of repair. Guarantee repairs will be carried out in company seat and guarantee period shall be lengthened by the time of repair. Technician is solely responsible for choosing the way of transport. Guarantee is not provided in case of loss or replacement of Guarantee Certificate, damage of product caused by natural disaster, during transport, by unsuitable positioning, unsuitable handling, and operation of device in unsuitable conditions, or in case of damage or removal of sealing labels. Guarantee does not apply to expendable property – dyeing ribbons, floppy discs, etc. It does not apply to malfunction caused by installed software or interference, too. Company is not responsible for possible losses, which originate from device failure either. Guarantee does not apply to malfunction caused by change of external conditions as change in legislation, change of phone network, change of supply network, etc. Guarantee is applied at presentation of completely filled-in Guarantee Certificate and device intended for repair including accessories. Duplicate of Guarantee Certificate is not issued; customer guarantees its correctness and originality.
25
26
GB 102 2xx @ 1.03 © LEVEL, 2005 LEVEL Ltd., Plhovská 1997, Náchod 547 01, CZECH REPUBLIC www.levelna.cz
27