Preview only show first 10 pages with watermark. For full document please download

Gbe Sfp Transceiver (40km) Rsp12sex

   EMBED


Share

Transcript

RoHS Compliant GbE SFP Transceiver (40km) RSP12SEX Applications   Gigabit Ethernet (1000 BASE-EX) 1X Fiber Channel Features Description            Up to 1.25Gb/s, 40km optical data link Compliant with SFP MSA Digital diagnostic SFF-8472 compliant Uncooled 1310nm DFB laser for 1000BaseEX application (40km) Wide dynamic range PIN-PD receiver Very low jitter Metal package for lower EMI Single power supply voltage : +3.3V Low power dissipation LC duplex connector Three optional operating temperature ranges : Option ST : -5°C to 75°C Option ET : -10°C to 85°C Option IT : -40°C to 85°C www.oesolution.com OE Solutions’ Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable 20pin Multi-Source Agreement (MSA). RSP12SEX complies with Gigabit Ethernet as specified in IEEE 802.3 and Fiber Channel FC-PI 13.0. Digital diagnostics functions are available via the 2-wire serial bus specified in the SFF-8472 rev.10.4. The transmitter part has 1310 nm DFB laser and back facet monitor. The receiver part has an InGaAs PIN-PD and a preamplifier. The transmitter features ac-coupled differential data inputs, and an LVTTL for Tx disable input and Tx fault output. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output. Circuit ground is internally isolated from frame ground. 1 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 1. General Operating Conditions Parameter Symbol Min. Typ. Max. Unit Notes Vcc_max 0 - 4.0 V - Operating Voltage Vcc 3.135 - 3.465 V - Total Current Icc - - 300 mA - Operating Case Temperature Top -40 - 85 °C 1,2 Storage Temperature Tst -40 - 85 °C - Absolute Supply Voltage Notes : 1. Measured on top side front center of SFP module. 2. There are three options of operating maximum temperature: Option ST: standard temperature from -5oC to 75oC, Option ET: extended temperature from -10oC to 85oC and Option IT: Industrial temperature from -40oC to 85oC. 2. Transmitter Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes Rin - 100 - Ω - Vin,pp 100 - 1000 mV - Tx Disable Voltage Vd 2.4 - V - Tx Enable Voltage Ven - - 0.8 V - Optical Power 1 Pout -3 - 2 dBm 1 Optical Extinction Ratio ER 9 - - dB - λ 1260 - 1360 nm - tr/tf - - 260 ps 2 σ - - 1 nm - SMSR 30 - - dB - RIN - - -120 dB/Hz - Deterministic Jitter DJ - - 80 ps - Total Jitter TJ - - 227 ps - Input Differential Impedance Single Ended Data Input Swing Optical Characteristics Optical Wavelength Optical Rise/Fall Time 2 Spectral Width (-20dB) Side Mode Suppression Ratio Relative Intensity Noise Notes : 1. Using 9/125 SMF 2. Unfiltered, 20%~80% values Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions. 2 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 3. Receiver Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter Symbol Min. Typ. Max. Unit Notes Vout,pp 200 - 600 mV - tr/tf - - 260 ps 1 Average Rx Sensitivity@GbE RSENS1 - - -25 dBm 2 Average Rx Sensitivity@ 1X FC RSENS2 - - -25 dBm 2 Maximum Input Power (Overload) Pmax 0 - - dBm - λc 1260 - 1600 nm - LOS Assert LOS_A -35 - - dBm - LOS De-assert LOS_D - - -25 dBm - 0.5 2 5 dB - Single Ended Data Output Swing Data Output Rise/Fall Time Optical Characteristics Optical Center Wavelength LOS Hysteresis Notes : 1. 20%~80% values 2. Measured with a PRBS of 27-1 at 1 x 10-12 BER, and 9.0 dB extinction ratio. 4. Pin Descriptions 20 Tx GND 1 Tx GND 19 TD- 2 Tx Fault 18 TD+ 3 Tx Disable 17 Tx GND 4 MOD-DEF(2) 16 VccT 5 MOD-DEF(1) 15 VccR 6 MOD-DEF(0) 14 Rx GND 7 Rate Select 13 RD+ 8 LOS 12 RD- 9 Rx GND 11 Rx GND 10 Rx GND Top of Board Bottom of Board SFP Transceiver Electrical Pad Layout 3 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 5. Pin Descriptions (continued) Plug Seq. * 1 Notes Transmitter Fault Indication 3 2 Tx Disable Transmitter Disable 3 3 4 MOD-DEF2 Module Definition 2 3 4 5 MOD-DEF1 Module Definition 1 3 4 6 MOD-DEF0 Module Definition 0 3 4 7 Rate-Select No User Connection 3 5 8 LOS Los of Signal 3 6 9 Rx GND Receiver Ground 1 1 10 Rx GND Receiver Ground 1 1 11 Rx GND Receiver Ground 1 1 12 RD- Receiver Negative Data Out 3 - 13 RD+ Receiver Positive Data Out 3 - 14 Rx GND Receiver Ground 1 1 15 VccR Receiver Power 2 3.3V±5% 16 VccT Transmitter Power 2 3.3V±5% 17 Tx GND Transmitter Ground 1 1 18 TD+ Transmitter Positive Data In 3 - 19 TD- Transmitter Negative Data In 3 - 20 Tx GND Transmitter Ground 1 1 Pin Symbol Description 1 Tx GND Transmitter Ground 2 Tx Fault 3 1 *Plug Seq. : Pin engagement sequence during hot plugging Notes : 1. Circuit ground is internally isolated from frame ground. Tx GND and Rx GND may be internally isolated within the TRx module. 2. Tx Fault is an open collector output that shall be pulled up with a 4.7k ~ 10k on the host board. Pull up voltage between 2.0V and VccT + 0.3V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault 3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7k ~ 10k. 4. MOD-DEF 0, 1, 2 are the SFP module definition pins. They should be pulled up with a 4.7k ~ 10k on the host board. The pull-up voltage shall be VccT. MOD-DEF0 indicates that the module is present. MOD-DEF1 is the clock line of 2-wire serial interface for serial ID MOD-DEF2 is the data line of 2-wire serial interface for serial ID 5. OE Solutions RSP12SEX SFP transceivers operate at 1x Fiber Channel, Gigabit Ethernet, and respective protocols without active control. 6. LOS is an open collector output. Shall be pulled up with a 4.7k ~ 10k on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation. 4 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 6. Outline Drawings Dimensions are in millimeters (inches) 5 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 7. PCB layout and Bezel recommendation Dimensions are in inches (millimeters) Notes : 1. Datum and basic dimensions established by customer. 2. Pads and vias are chassis ground, 11 locations 3. Thru holes, plating optional. 6 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 8. PCB layout and Bezel recommendation (continued) Notes : Thru holes, plating optional. Recommended Panel Opening 7 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 9. Power Supply Information 1H VccT 0.1F 1H VccR 3.3V 0.1F 10F 0.1F 10F HOST BOARD SFP MODULE Recommended Host Board Supply Filtering Network PROTOCOL Vcc 1H 3.3V SFP MODULE 1H PROTOCOL Vcc 10F 0.1F 0.1F 4.7k-10k VccT 4.7k-10k Tx_Disable Tx_Disable Tx_Fault Tx_Fault TD+ 0.1F 100 TDPROTOCOL IC VEET SERDES IC 4.7k-10k 10F 0.1F RD+ 100 RD- LASER DRIVER 0.1F VccR 0.1F 0.1F PREAMP & QUANTIZER Rx_LOS Rx_LOS Rate_Select 3.3V VEER 4.7k10k 4.7k10k 4.7k10k MOD_DEF 0 MOD_DEF 1 PLD/PAL MOD_DEF 2 SFP Host Board Schematic 8 Rev. A.2, 07/30/2013 RSP12SEX SFP Transceiver Product Specifications 10. Diagnostics A2h address Parameter Calibration Accuracy Range o 96-97 Temperature External +/- 3 C Note 1 98-99 Vcc External +/- 3% 3.135 to 3.465 100-101 Tx bias External +/- 10% Note 2 102-103 Tx power External +/- 3dB -3 to 2dBm 104-105 Rx Power External +/- 3dB -25 to 0dBm Note: 1) Junction temperature of temperature sensing device. 2) Specified by nominal value 10. Ordering Information RSP12SEX-ST3 TBD RSP12SEX-ET3 TBD Operating Temperature -5oC to 75oC -10oC to 85oC RSP12SEX-IT3 31407 -40oC to 85oC Model Name P Code Nominal Wavelength 1310nm Latch Color Brown Power Budget 22dB Distance1 1310nm Brown 22dB 40Km 1310nm Brown 22dB 40Km 40Km Notes : 1. The transmission distance shown is for guidelines only, not guaranteed. Longer distances can be supported if the power budget of optical link is satisfied. Revision History Date Rev. # Description Author 01/31/2006 Rev. A.0 first release MSPARK 04/01/2009 Rev. A.1 mechanical drawing updated MSPARK 07/30/2013 Rev. A.2 Tx output, Rx sensitivity revised. A new pcode assigned JSYU Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com. OE Solutions America, Inc. 560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188, Fax:201-568-1177 9 Rev. A.2, 07/30/2013