Transcript
RoHS Compliant
GbE SFP Transceiver (40km) RSP12SEX
Applications
Gigabit Ethernet (1000 BASE-EX) 1X Fiber Channel
Features Description
Up to 1.25Gb/s, 40km optical data link Compliant with SFP MSA Digital diagnostic SFF-8472 compliant Uncooled 1310nm DFB laser for 1000BaseEX application (40km) Wide dynamic range PIN-PD receiver Very low jitter Metal package for lower EMI Single power supply voltage : +3.3V Low power dissipation LC duplex connector Three optional operating temperature ranges : Option ST : -5°C to 75°C Option ET : -10°C to 85°C Option IT : -40°C to 85°C
www.oesolution.com
OE Solutions’ Small Form Factor Pluggable (SFP) transceivers are compatible with the Small Form Factor Pluggable 20pin Multi-Source Agreement (MSA). RSP12SEX complies with Gigabit Ethernet as specified in IEEE 802.3 and Fiber Channel FC-PI 13.0. Digital diagnostics functions are available via the 2-wire serial bus specified in the SFF-8472 rev.10.4. The transmitter part has 1310 nm DFB laser and back facet monitor. The receiver part has an InGaAs PIN-PD and a preamplifier. The transmitter features ac-coupled differential data inputs, and an LVTTL for Tx disable input and Tx fault output. The receiver features differential ac-coupled data outputs and LVTTL for LOS (Loss of Signal) output. Circuit ground is internally isolated from frame ground.
1
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
1. General Operating Conditions Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vcc_max
0
-
4.0
V
-
Operating Voltage
Vcc
3.135
-
3.465
V
-
Total Current
Icc
-
-
300
mA
-
Operating Case Temperature
Top
-40
-
85
°C
1,2
Storage Temperature
Tst
-40
-
85
°C
-
Absolute Supply Voltage
Notes :
1. Measured on top side front center of SFP module. 2. There are three options of operating maximum temperature: Option ST: standard temperature from -5oC to 75oC, Option ET: extended temperature from -10oC to 85oC and Option IT: Industrial temperature from -40oC to 85oC.
2. Transmitter Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Rin
-
100
-
Ω
-
Vin,pp
100
-
1000
mV
-
Tx Disable Voltage
Vd
2.4
-
V
-
Tx Enable Voltage
Ven
-
-
0.8
V
-
Optical Power 1
Pout
-3
-
2
dBm
1
Optical Extinction Ratio
ER
9
-
-
dB
-
λ
1260
-
1360
nm
-
tr/tf
-
-
260
ps
2
σ
-
-
1
nm
-
SMSR
30
-
-
dB
-
RIN
-
-
-120
dB/Hz
-
Deterministic Jitter
DJ
-
-
80
ps
-
Total Jitter
TJ
-
-
227
ps
-
Input Differential Impedance Single Ended Data Input Swing
Optical Characteristics
Optical Wavelength Optical Rise/Fall Time
2
Spectral Width (-20dB) Side Mode Suppression Ratio Relative Intensity Noise
Notes :
1. Using 9/125 SMF 2. Unfiltered, 20%~80% values
Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
2
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
3. Receiver Specifications (Over Operating Case Temperature Range, Vcc = 3.135V to 3.465V) Electrical Characteristics Parameter
Symbol
Min.
Typ.
Max.
Unit
Notes
Vout,pp
200
-
600
mV
-
tr/tf
-
-
260
ps
1
Average Rx Sensitivity@GbE
RSENS1
-
-
-25
dBm
2
Average Rx Sensitivity@ 1X FC
RSENS2
-
-
-25
dBm
2
Maximum Input Power (Overload)
Pmax
0
-
-
dBm
-
λc
1260
-
1600
nm
-
LOS Assert
LOS_A
-35
-
-
dBm
-
LOS De-assert
LOS_D
-
-
-25
dBm
-
0.5
2
5
dB
-
Single Ended Data Output Swing Data Output Rise/Fall Time Optical Characteristics
Optical Center Wavelength
LOS Hysteresis Notes :
1. 20%~80% values 2. Measured with a PRBS of 27-1 at 1 x 10-12 BER, and 9.0 dB extinction ratio.
4. Pin Descriptions 20
Tx GND
1
Tx GND
19
TD-
2
Tx Fault
18
TD+
3
Tx Disable
17
Tx GND
4
MOD-DEF(2)
16
VccT
5
MOD-DEF(1)
15
VccR
6
MOD-DEF(0)
14
Rx GND
7
Rate Select
13
RD+
8
LOS
12
RD-
9
Rx GND
11
Rx GND
10
Rx GND
Top of Board
Bottom of Board
SFP Transceiver Electrical Pad Layout
3
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
5. Pin Descriptions (continued) Plug Seq. * 1
Notes
Transmitter Fault Indication
3
2
Tx Disable
Transmitter Disable
3
3
4
MOD-DEF2
Module Definition 2
3
4
5
MOD-DEF1
Module Definition 1
3
4
6
MOD-DEF0
Module Definition 0
3
4
7
Rate-Select
No User Connection
3
5
8
LOS
Los of Signal
3
6
9
Rx GND
Receiver Ground
1
1
10
Rx GND
Receiver Ground
1
1
11
Rx GND
Receiver Ground
1
1
12
RD-
Receiver Negative Data Out
3
-
13
RD+
Receiver Positive Data Out
3
-
14
Rx GND
Receiver Ground
1
1
15
VccR
Receiver Power
2
3.3V±5%
16
VccT
Transmitter Power
2
3.3V±5%
17
Tx GND
Transmitter Ground
1
1
18
TD+
Transmitter Positive Data In
3
-
19
TD-
Transmitter Negative Data In
3
-
20
Tx GND
Transmitter Ground
1
1
Pin
Symbol
Description
1
Tx GND
Transmitter Ground
2
Tx Fault
3
1
*Plug Seq. : Pin engagement sequence during hot plugging Notes : 1. Circuit ground is internally isolated from frame ground. Tx GND and Rx GND may be internally isolated within the TRx module. 2. Tx Fault is an open collector output that shall be pulled up with a 4.7k ~ 10k on the host board. Pull up voltage between 2.0V and VccT + 0.3V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault 3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7k ~ 10k. 4. MOD-DEF 0, 1, 2 are the SFP module definition pins. They should be pulled up with a 4.7k ~ 10k on the host board. The pull-up voltage shall be VccT. MOD-DEF0 indicates that the module is present. MOD-DEF1 is the clock line of 2-wire serial interface for serial ID MOD-DEF2 is the data line of 2-wire serial interface for serial ID 5. OE Solutions RSP12SEX SFP transceivers operate at 1x Fiber Channel, Gigabit Ethernet, and respective protocols without active control. 6. LOS is an open collector output. Shall be pulled up with a 4.7k ~ 10k on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation.
4
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
6. Outline Drawings Dimensions are in millimeters (inches)
5
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
7. PCB layout and Bezel recommendation Dimensions are in inches (millimeters)
Notes :
1. Datum and basic dimensions established by customer. 2. Pads and vias are chassis ground, 11 locations 3. Thru holes, plating optional.
6
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
8. PCB layout and Bezel recommendation (continued)
Notes : Thru holes, plating optional.
Recommended Panel Opening
7
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
9. Power Supply Information 1H VccT 0.1F 1H VccR
3.3V 0.1F
10F
0.1F
10F
HOST BOARD SFP MODULE
Recommended Host Board Supply Filtering Network
PROTOCOL Vcc
1H 3.3V
SFP MODULE
1H PROTOCOL Vcc
10F 0.1F
0.1F
4.7k-10k
VccT 4.7k-10k
Tx_Disable
Tx_Disable
Tx_Fault
Tx_Fault
TD+
0.1F 100
TDPROTOCOL IC
VEET SERDES IC
4.7k-10k
10F
0.1F RD+
100 RD-
LASER DRIVER
0.1F
VccR
0.1F
0.1F
PREAMP & QUANTIZER
Rx_LOS
Rx_LOS
Rate_Select 3.3V VEER 4.7k10k
4.7k10k
4.7k10k MOD_DEF 0 MOD_DEF 1
PLD/PAL
MOD_DEF 2
SFP Host Board Schematic
8
Rev. A.2, 07/30/2013
RSP12SEX SFP Transceiver Product Specifications
10. Diagnostics A2h address
Parameter
Calibration
Accuracy
Range
o
96-97
Temperature
External
+/- 3 C
Note 1
98-99
Vcc
External
+/- 3%
3.135 to 3.465
100-101
Tx bias
External
+/- 10%
Note 2
102-103
Tx power
External
+/- 3dB
-3 to 2dBm
104-105
Rx Power
External
+/- 3dB
-25 to 0dBm
Note: 1) Junction temperature of temperature sensing device. 2) Specified by nominal value
10. Ordering Information
RSP12SEX-ST3
TBD
RSP12SEX-ET3
TBD
Operating Temperature -5oC to 75oC -10oC to 85oC
RSP12SEX-IT3
31407
-40oC to 85oC
Model Name
P Code
Nominal Wavelength 1310nm
Latch Color Brown
Power Budget 22dB
Distance1
1310nm
Brown
22dB
40Km
1310nm
Brown
22dB
40Km
40Km
Notes : 1. The transmission distance shown is for guidelines only, not guaranteed. Longer distances can be supported if the power budget of optical link is satisfied.
Revision History
Date
Rev. #
Description
Author
01/31/2006
Rev. A.0
first release
MSPARK
04/01/2009
Rev. A.1
mechanical drawing updated
MSPARK
07/30/2013
Rev. A.2
Tx output, Rx sensitivity revised. A new pcode assigned
JSYU
Contact Information: OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com.
OE Solutions America, Inc.
560 Sylvan Avenue, 1st Floor, Englewood Cliffs, NJ 07632 Tel: 201-568-1188, Fax:201-568-1177
9
Rev. A.2, 07/30/2013