Preview only show first 10 pages with watermark. For full document please download

Ge Security Fire Accessories Product Catalogue

   EMBED


Share

Transcript

GE Security Fire Accessories Product Catalogue g In this catalogue you will find a wide range of Fire Protection equipment from GE Security. GE Security is a global technology leader dedicated to supporting the needs of the rapidly growing electronic security industry and to expanding current technologies, products and services that GE Security, unrivalled expertise in Fire Protection create revenue growth opportunities for its customers. As part of the GE family, GE Security shares the spirit of innovation that has distinguished GE for well over 100 years. GE Security's commitment to the ongoing success of its partners and affiliates means that we maintain a sharp focus on product and service innovation, world-class manufacturing practices and operational excellence. GE Security is a worldwide organisation with sales and technical support operations in 27 countries, and manufacturing and logistics operations in Europe, the U.S. and China. GE Security has expertise in all areas of electronic security, including: z Intrusion and Fire Protection z Electronic Access and Facility Management z Key Management and Remote Access Systems and Services z Fibre Optic Transmission and Reception Equipment z CCTV, Digital Video and Surveillance Equipment z Video Multiplexing and Digital Storage When you're looking for the finest in Fire Protection products with leading-edge technology and the backing of a world leader, you need look no further than this catalogue. Aspiration Systems Page : 3 FDD700 Single pipe universal duct detector The FDD700 single pipe duct detector has been developed to detect smoke in ventilation ducts and combines a smoke detector and an adaptor system where both tube and housing are specially designed for optimum airflow through the smoke detector. The system fulfils all the requirements for safe fire detection with airflow speeds from 0,2 m/s to 20 m/s. The FDD700 has the correct adaptor profiles to accomodate any of the 700, 2000, 300, or 1500 series smoke detectors. Provision is made to fit the required detector base (not provided) into the duct detector. Specifications Smoke detector types 300, 700, 1500, 2000 series Sampling pipe length 600 mm Airflow speed 0.2 m/s - 20 m/s Protection IP54 Housing ABS Operating temperature -20°C to +50°C Dimensions 300 x 150 x 110 mm Colour Grey Ordering Information FDD700 Single pipe universal duct detector FDD700LP Extra-long sampling pipe for the FDD700 duct detector, 1.5m FDD700MB Mounting bracket for irregular shape and circular ducts E E E E E E E E E E One-tube air sampling system Conventional or analogue addressable detectors Test hole on cover Simple installation Sensitive flow indication Simple service and maintenance Installer-friendly connection of cables Foolproof installation of sampling tube Special profile for 700 series and 2000 series detectors Special profile for 300 series and 1500 series detectors Aspiration Systems Page : 4 FDD700LP Extra-long sampling pipe for the FDD700 duct detector, 1.5m The 1.5m extra-long sampling pipe is used with the FDD700 duct detector. It allows sampling in ducts that are too large for the 600mm sampling pipe normally supplied. The pipe may be cut to get an exact fit into the duct. Specifications Pipe length 1.5 m Compatible system FDD700 Ordering Information FDD700LP Extra-long sampling pipe for the FDD700 duct detector, 1.5m E E E E Used with FDD700 duct detector Extra long for large ducts Unique one-pipe sampling system Easy installation FDD700MB Mounting bracket for irregular shape and circular ducts The FDD700MB allows the FDD700 duct detector to be mounted on irregular shaped or circular ducts. Four tabs are easily bent to adapt to the shape of the duct. The FDD700 then mounts on the flat surface. Ordering Information FDD700MB Mounting bracket for irregular shape and circular ducts E Four tabs adapt to the shape of the duct Aspiration Systems Page : 5 ASD20C Aspiration Smoke Detector The ASD20 Aspiration Smoke Detector consists of an analysis chamber with one or two smoke detectors, connected to standard 25 mm Ø PVC piping. The detectors can be of conventional or analogue technology, ionisation or optical. Specifications Power supply voltage 24 VDC Current Consumption Standby 250 mA 1st alarm 280 mA 2nd alarm 320 mA Fault 220 mA Environmental Characteristics Working temperature -10 to +60°C Storage temperature -10 to +70°C Relative humidity <95% Physical Characteristics Size 314 x 254 x 115 Weight 4 kg Colour RAL9999 Material Polycarbonate Cable input 3 x PG11 Wire cross-section Max. 1.5 mm² Coverage area per intake 30 m² Maximum num. of intakes 12 DIN 8062-type PVC pipes Ø25 mm Useful lifetime of motor 65 000 hours at 40°C Ordering Information ASD20C Aspiration Smoke Detector ASD20F Filter housing for ASD20 ASD20FIL Filter only for ASD20 E Used with conventional or analogue detectors E Direct connection to an analogue loop or stand-alone operation E E E E E Alarm 1, alarm 2 and fault relay outputs 24 VDC power supply Simple and robust architecture 30 m² coverage per sample intake Standard 25 mm PVC piping system E Installation of piping in I-shape and U-shape (symmetrical or assymmetrical) E Continuous supervision of pipe flow volume Aspiration Systems Page : 6 ASD20F Filter housing for ASD20 The ASD20F is an aluminium filter housing for the ASD20 aspiration detection system. It houses and protects the the air filter, the ASD20FIL, that has to be ordered seperately. Ordering Information ASD20F Filter housing for ASD20 ASD20FIL Filter only for ASD20 E Robust, light weight, aluminium construction E Easy to install E Easy filter replacement Filter only for ASD20 Filter only for ASD20 Aspiration Detector. Ordering Information ASD20FIL Filter only for ASD20 ASD20FIL Aspiration Systems Page : 7 FASD710 High-performance aspiration controller for point detectors The FASD710 provides a low cost solution for aspiration systems using point smoke detectors. The controller can be used in many applications where point smoke detectors are not suitable. The powerful pump allows pipe distances of up to 100 metres. Specifications Dimensions (w x l x h) 254 x 180 x 165 mm Supply voltage 24 VDC Current consumption 460 mA Number of detectors (not included) 2 Filtration Cartridge dust particle filter Maximum tube length 100 m Flow monitoring yes Environmental IP rating IP50/IP65 Operating Temperature -10 to 60 °C Operating Humidity 10 to 95% RH (non-condensing) Ordering Information E 2 Detectors for redundancy and mixed detection strategy FASD710 High-performance aspiration controller for point detectors FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 FHSD776 Large bore red pipe 3 metre length Straight union large bore 90 deg. bend for large bore pipes 45 deg. elbow for large bore pipes End cap for large bore pipes Removable Union for Large Bore Red Pipe 25 mm E E E E E E E E E E E E E E E Up to 100 metres pipe Cartridge air filter Bar graph indication of flow High / low flow fault and remote reporting IP65 rating available Could be used in applications such as: - Hotels - Banks - Hospitals - Livestock Buildings - Prisons - Underground stations - Aesthetic environments - Harsh environments - Dirty environments Aspiration Systems Page : 8 FHSD720 Localised aspirated early warning smoke detection system Compact and powerful, the FHSD720 has all the detection and monitoring features of big aspiration systems. It is ideal for monitoring localised areas up to 850m². All data can be uploaded or downloaded via the standard RS232 or RS485 ports Specifications Power supply 24V, 600ma min, 1,5A max Smoke detector Resolution 0.005%, range 20% Light source 50mW 660nm high power laser diode Number of inlets 2 (ground and ceiling), 1 address Pipe size 25mm Oudside Diameter Pipe lenght 70 meters Aspirator 800Pa static pressure Area coverage 850m² Alarm levels 4: alert, action, fire1, fire2 Alarm setting range 0.005% - 20.0% Outputs 4 alarm relays, 1 fault relay, 1A change over Communication RS232, Modbus, RS485 Weight 3kg Humidity 0-95% Temperature 0 - 50 °C Ordering Information FHSD720 FHSD720RL FHSD732 FHSD733 FHSD751 FHSD754 FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 Localised aspirated early warning smoke detection system Relay Module 4 Channel for FHSD72x Single channel remote display & programmer Remote display repeater unit - 16 units Filter+ with filter element - harsh environment Replacement filter element for the FHSD751 Large bore red pipe 3 metre length Straight union large bore 90 deg. bend for large bore pipes 45 deg. elbow for large bore pipes End cap for large bore pipes E E E E E E E E E E E E IP65 RS232 and RS485 standard High Power Pump High sensitivity laser detector Four alarm levels Remote display units 24V operation Fault monitoring Small EDP rooms Server rooms Escalators Machine protection Aspiration Systems Page : 9 Four pipe, one address aspirated early warning smoke detection system The FHSD721 4 pipe aspirating laser detector system provides very early warning to smoke over a very large area. Each pipe can be up to 100 metres long. Specifications Power supply 24 VDC, 600 mA min, 1.5 A max Smoke dectector Resolution 0.005%, range 20% Light source 50 mW 660nm high power laser diode Expected lifetime 10 years Number of inlets 4 (non addressable) Pipe size 25 mm outside diameter Pipe length 100 meters each Aspirator 2000 Pa high vacuum centrifugal blower Alarm levels alert, action, fire1, fire2 Alarm setting range 0.005% - 20.0% Alarm delay 0 - 60 s, individually programmable Outputs 4 alarm relays, 1 fault relay, 1 A c/o Communication RS232, Modbus RS485 Webserver option (FHSD721D only) Ethernet 10 BaseT/RS232 MODEM, TCP/IP Weight 10.7 kg Humidity 0 - 95 % Temperature 0 - 50 °C Ordering Information FHSD721 Four pipe, one address aspirated early warning smoke detection system FHSD720PS PSU Batt charger 230V for FHSD721-FHSD7215 FHSD720RL Relay Module 4 Channel for FHSD72x FHSD731 FHSD732 FHSD733 FHSD751 FHSD752 FHSD753 FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 FHSD776 FHSD777CE FHSD778 FHSD779 Conversion kit for remote display Single channel remote display & programmer Remote display repeater unit - 16 units Filter+ with filter element - harsh environment Filter in-line single stage Filter in-line 3 stage Large bore red pipe 3 metre length Straight union large bore 90 deg. bend for large bore pipes 45 deg. elbow for large bore pipes End cap for large bore pipes Removable Union for Large Bore Red Pipe 25 mm Wall Anchor Clip for 25 mm pipe Flush Capillary Sampling Point T-Piece for 25mm pipe E E E E E E E E Early warning applications Detection with high airflows Unobtrusive detection Ideal for large open areas For inaccessible areas For dusty and humid environments For tamperproof installations Webserver optional FHSD721 Aspiration Systems Page : 10 Four channel four area aspirated early warning smoke detection system The FHSD724 four channel large bore aspirating laser detector system provides very early warning to smoke over a very large area. Each pipe can be up to 100 metres long. The unit is complete with display and programmer. Specifications Power supply 24V, 600ma min, 1.5A max Smoke detector 230V 5A PSU / battery charger, optional Resolution 0.005%, range 20% Light source 50mW 660nm high power laser diode Expected lifetime 10 years Number of inlets 6, fully addressable Pipe size 25mm outside diameter Pipe length 100 meter each Aspirator 2000 Pa high vacuum centrifugal blower Alarm levels 4: alert, action, fire1, fire2 Alarm setting range 0.005% - 20% Alarm delay 0 - 60 secs, individually programmable Outputs 4 alarm relays, 1 fault relay, 1A c/o Communication RS232, Modbus RS485 Web server Weight Communication: Ethernet 10 BaseT/RS232 MODEM, TCP / IP 24V: 10.7 kg, 230V PSU: 14.5kg Humidity 0 - 95% Temperature 0 - 50 °C Ordering Information FHSD724D Four channel four area aspirated early warning smoke detection system FHSD720PS PSU Batt charger 230V for FHSD721-FHSD7215 FHSD720RL Relay Module 4 Channel for FHSD72x FHSD731 FHSD732 FHSD733 FHSD751 FHSD752 FHSD753 FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 FHSD776 FHSD777CE FHSD778 FHSD779 Conversion kit for remote display Single channel remote display & programmer Remote display repeater unit - 16 units Filter+ with filter element - harsh environment Filter in-line single stage Filter in-line 3 stage Large bore red pipe 3 metre length Straight union large bore 90 deg. bend for large bore pipes 45 deg. elbow for large bore pipes End cap for large bore pipes Removable Union for Large Bore Red Pipe 25 mm Wall Anchor Clip for 25 mm pipe Flush Capillary Sampling Point T-Piece for 25mm pipe E E E E E E E Early warning applications Detection with high inflows Unobtrusive detection Ideal for large open areas For inaccessible areas For dusty and humid environments For tamperproof installations FHSD724D Aspiration Systems Page : 11 Six channel six area aspirated early warning smoke detection system High sensitivity detection The FHSD726 six channel large bore aspirating laser detector system provides very early warning to smoke over a very large area. Each pipe can be up to 100 metres long. An environmental detector is also available Specifications Power supply 24V, 600ma min, 1.5A max Smoke Detector Resolution: 0.005%, range: 20% Light Source 50mW 660nm high power laser diode Expected life time 10 years Number of inlets 6 (fully addressable) Pipe size 25mm outside diameter Aspirator 2000Pa high vacuum centrifugal blower Pipe length 100 meters each Alarm levels 4 Alarm setting range 0.005% - 20.0% Alarm delay 1-60 Secs, individually programmable Outputs 4 alarm relays, 1 A C/O Communication RS232, Modbus RS485 Web Server Ethernet 10 BaseT/RS232 MODEM, TCP / IP Environmental Weight 24V 10.7 KG, 230VPSU 14.5 KG Humidity 0-95% Ordering Information FHSD726D FHSD726DE FHSD720PS FHSD720RL FHSD731 FHSD732 FHSD733 FHSD751 FHSD754 FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 Aspirating laser detector six pipe complete with display Aspirating laser and environmental detector, six pipe c/w display PSU Batt charger 230V for FHSD721-FHSD7215 Relay Module 4 Channel for FHSD72x Conversion kit for remote display Single channel remote display & programmer Remote display repeater unit - 16 units Filter+ with filter element - harsh environment Replacement filter element for the FHSD751 Large bore red pipe 3 metre length Straight union large bore 90 deg. bend for large bore pipes 45 deg. elbow for large bore pipes End cap for large bore pipes E E E E E E E Early warning applications Detection with high airflows Unobtrusive detection Ideal for large open areas For inaccessible areas For dusty and humid environments For tamperproof installations FHSD726 Aspiration Systems Page : 12 15 Channel Micro bore aspirated early warning smoke detection system Selective detection The FHSD7215D 15 channel micro bore aspirating laser detector system provides very early warning to smoke over a very large area. Fifteen fully addressable areas. Each pipe can be up to 50 metres long. Specifications Power supply 24V, 600ma min, 1.5A max Smoke detector Resolution 0.005%, range 20% Light source 50mW 660nm high power laser diode Expected lifetime 10 years Number of inlets 15, fully addressable Tube size Aspirator Micro bore 6mm o.d, 4mm i.d , flexible nylon or FEP tubing 0.8 bar rotary vane vacuum pump Pipe length 50 meters each Alarm levels 4: alert, action, fire1, fire2 Alarm setting range 0.005% - 20.0% Alarm delay 0-60 seconds, individually programmable Outputs 4 alarm relays, 1 fault relay, 1A c/o Communication RS232, Modbus RS485 Web server Ethernet 10 BaseT/RS232 MODEM, TCP / IP Weight 24V: 10.7 kg, 230V PSU: 14.5 kg Humidity 0 - 95 % Ordering Information FHSD7215D FHSD720PS FHSD720RL FHSD731 FHSD732 FHSD733 FHSD752 FHSD753 FHSD755 FHSD756 FHSD761 FHSD762 FHSD763 FHSD764 15 Channel Micro bore aspirated early warning smoke detection system PSU Batt charger 230V for FHSD721-FHSD7215 Relay Module 4 Channel for FHSD72x Conversion kit for remote display Single channel remote display & programmer Remote display repeater unit - 16 units Filter in-line single stage Filter in-line 3 stage Replacement filter element set - medium / fine for the FHSD753 Replacement filter element pack of 10 - coarse - for the FHSD753 Micro bore 6mm sampling tube - 30 meter reel Straight union for micro bore 6mm tube Tee union for micro bore 6mm tube Scintered end of line filter for micro bore 6mm tube E E E E E E E E Early warning applications Detection with high airflows Unobtrusive detection Ideal for large open areas For inaccessible areas For dusty and humid environments For tamperproof installations Micro bore pipes FHSD7215D Aspiration Systems Page : 13 PSU Batt charger 230V for FHSD721-FHSD7215 FHSD720PS A 230V power supply, battery charger and battery container for the FHSD721, FHSD724, FHSD726, and FHSD7215 apiration systems. The power supply is easily mounted in the units. Ordering Information FHSD720PS PSU Batt charger 230V for FHSD721-FHSD7215 Relay Module 4 Channel for FHSD72x This four way relay module extends the outputs of the FHSD72x aspiration systems. It is plug-in installable. Ordering Information FHSD720RL Relay Module 4 Channel for FHSD72x FHSD720RL Aspiration Systems Page : 14 Conversion kit for remote display FHSD731 This kit allows the display panel of a FHSD72xD aspiration system to be removed from the unit and to be mounted remotely. Ordering Information FHSD731 Conversion kit for remote display Single channel remote display & programmer Ordering Information FHSD732 Single channel remote display & programmer FHSD732 Aspiration Systems Page : 15 Remote display repeater unit - 16 units FHSD733 A remote display channel allowing the connection of up to16 aspiration systems on a RS485 bus. Ordering Information FHSD733 Remote display repeater unit - 16 units Filter+ with filter element - harsh environment For use with large bore systems Ordering Information FHSD751 Filter+ with filter element - harsh environment FHSD751 Aspiration Systems Page : 16 Filter in-line single stage FHSD752 A single stage filter for micro-bore systems Ordering Information FHSD752 Filter in-line single stage Filter in-line 3 stage A three stage filter with course, medium, and fine filters for micro-bore systems Ordering Information FHSD753 Filter in-line 3 stage FHSD753 Aspiration Systems Page : 17 Replacement filter element for the FHSD751 FHSD754 Ordering Information FHSD754 Replacement filter element for the FHSD751 Replacement filter element set - medium / fine for the FHSD753 Ordering Information FHSD755 Replacement filter element set - medium / fine for the FHSD753 FHSD755 Aspiration Systems Page : 18 Replacement filter element pack of 10 - coarse - for the FHSD753 FHSD756 Ordering Information FHSD756 Replacement filter element pack of 10 - coarse - for the FHSD753 Micro bore 6mm sampling tube - 30 meter reel Ordering Information FHSD761 Micro bore 6mm sampling tube - 30 meter reel FHSD761 Aspiration Systems Page : 19 Straight union for micro bore 6mm tube FHSD762 Ordering Information FHSD762 Straight union for micro bore 6mm tube Tee union for micro bore 6mm tube Ordering Information FHSD763 Tee union for micro bore 6mm tube FHSD763 Aspiration Systems Page : 20 Scintered end of line filter for micro bore 6mm tube FHSD764 Ordering Information FHSD764 Scintered end of line filter for micro bore 6mm tube Large bore red pipe 3 metre length Ordering Information FHSD771 Large bore red pipe 3 metre length FHSD771 Aspiration Systems Page : 21 Straight union large bore FHSD772 Ordering Information FHSD772 Straight union large bore 90 deg. bend for large bore pipes Ordering Information FHSD773 90 deg. bend for large bore pipes FHSD773 Aspiration Systems Page : 22 45 deg. elbow for large bore pipes FHSD774 Ordering Information FHSD774 45 deg. elbow for large bore pipes End cap for large bore pipes Ordering Information FHSD775 End cap for large bore pipes FHSD775 Flame Detectors Page : 23 FF711 UV flame detector complete with base Ultra violet (UV) models have a quick and efficient response to flame. The FF711 detectors have a wide field of vision of up to 120°. Specifications Supply voltage 12 - 30 VDC Supply current Quiescent 3 mA Alarm > 20 mA Relay contact rating Field of view Up to 120° Spectral response (IR) Spectral response (UV) 185 to 260 nm Response time <2s Operating temperature -10°C to +60°C Relative humidity 95% Non condensing Weight 150 g (including base) Housing Colour Light Cream Material Plasic Ordering Information FF711 UV flame detector complete with base FF703 UV/IR universal test torch E E E E E E E E UV models Low cost units for indoor applications Flame proof model available Fast response (1 - 2 seconds) Wide operating voltage Wide cone of vision - up to 120° 2 Wire and relay options available Versatile, adjustable test torch available Flame Detectors Page : 24 24 VDC relay base for FF711 24 VDC relay base for FF711 Ordering Information FF711R 24 VDC relay base for FF711 FF711R Flame Detectors Page : 25 FF713 UV flame detector self contained with fire and fault relays The FF713 is a UV flame detector, self contained with fire and fault relays. Specifications Supply voltage 12 - 30 VDC Supply current Quiescent - Alarm 4 mA Relay contact rating 1A @ 30 VDC (resistive load) Field of view Up to 120° Spectral response (IR) - Spectral response (UV) 185 to 260 nm Response time - Operating temperature -10°C to +60°C Relative humidity 95% Non condensing Weight 655 g Housing Colour - Material - Ordering Information FF713 UV flame detector self contained with fire and fault relays FF705 Adjustable mounting bracket FF701 UV test torch FF703 UV/IR universal test torch E E E E E E E E E UV, IR and UV/IR models Low cost units for indoor applications Flame proof model available Fast response (1 - 2 seconds) Wide operating voltage Wide cone of vision - up to 120° 2 Wire and relay operation Versatile, adjustable test torch available Optional universal mounting bracket Flame Detectors Page : 26 FF716 UV flame detector in flame proof enclosure The FF716 UV Flame Detector has been developed to fill the need for a basic flameproof (explosion proof) UV Flame Detector for low budget applications. Specifications Supply voltage 12 - 30 VDC Supply current Quiescent 3 mA Alarm > 20 mA Relay contact rating 1A @ 30 VDC (resistive load) Field of view Up to 120° Spectral response (IR) Spectral response (UV) 185 to 260 nm Response time < 2s Operating temperature -10°C to +60°C Relative humidity 95% Non condensing Weight 2.2 kg Housing Colour Red Material Copper free aluminium alloy Ordering Information FF716 UV flame detector in flame proof enclosure FF703 UV/IR universal test torch E E E E E E E E UV flame detector Low cost Housing CENELEC cert. to EExd IIC T6 Fast response (1 - 2 seconds) Wide operating voltage Wide cone of vision - up to 120° 2 Wire or optional relay operation Versatile, adjustable test torch available Flame Detectors Page : 27 FF721 Dual IR flame detector complete with 2 wire base The FF721 is a Dual IR flame detector complete with 2 wire base. Specifications Supply voltage 24 VDC Supply current Quiescent 180 A Alarm 65 mA max Relay contact rating - Field of view 100° Spectral response (IR) 4.3 and 4.0 m Spectral response (UV) - Response time - Operating temperature -10°C to +50°C Relative humidity 95% Non condensing Weight 200g Housing Colour - Material - Ordering Information FF721 Dual IR flame detector complete with 2 wire base E E E E E E E E E UV, IR and UV/IR models Low cost units for indoor applications Flame proof model available Fast response (1 - 2 seconds) Wide operating voltage Wide cone of vision - up to 120° 2 Wire and relay operation Versatile, adjustable test torch available Optional universal mounting bracket Flame Detectors Page : 28 FF741 Dual IR flame detector in glass reinforced polycarbonate housing Specifications Supply voltage 14 - 28 V dc Supply current 3/9, 4/8/14, 4-20, 8-20 mA Relay contact ratings 1 A @ 30 VDC (resistive load) Field of view 90° min. cone Spectral response (IR) 1.0 to 2 m Operating temperature -10°C to 55°C Storage temperature -20°C to 65°C Relative humidity 95%; non-condensing IP Rating IP64 poly carbonate box Weight IP65 die-cast zinc alloy box IP66 flame proof box 1 kg die-cast zinc ally box 2 kg flame proof box Ordering Information FF741 FF742 FF746 FF747 Dual IR flame detector in glass reinforced polycarbonate housing Dual IR flame detector in die-cast zinc alloy housing Dual IR flame detector in Eexd - IIC T6 flame proof housing Dual IR Intrinsic safe flame detector in die-cast zinc alloy housing E E E E E E E E E E E E E Dual IR and UV/Dual IR models High specification units for critical applications IP65 Housing available Flame proof and Intrinsic safe models Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Versatile mounting brackets Tolerance to detector window contamination Versatile, adjustable test torch available Remote self test facility Microprocessor controlled E Immunity to false sources (arc welding, lightning and static) E Conforms to EN54: Part 10 Flame Detectors Page : 29 FF751 UV / Dual IR flame detector in die cast zinc alloy housing Specifications Supply voltage 14 - 28 V dc Supply current 3/9, 4/8/14, 4-20, 8-20 mA Relay contact ratings 1 A @ 30 VDC (resistive load) Field of view 90° min. cone Spectral response (IR) 1.0 to 2 m Operating temperature -10°C to 55°C Storage temperature -20°C to 65°C Relative humidity 95%; non-condensing IP Rating IP64 poly carbonate box Weight IP65 die-cast zinc alloy box IP66 flame proof box 1 kg die-cast zinc ally box 2 kg flame proof box Ordering Information FF751 UV / Dual IR flame detector in die cast zinc alloy housing FF756 UV / Dual IR flame detector in Eexd - IIC T6 flame proof housing E E E E E E E E E E E E E Dual IR and UV/Dual IR models High specification units for critical applications IP65 Housing available Flame proof and Intrinsic safe models Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non latching operation High / Low sensitivity setting Versatile mounting brackets Tolerance to detector window contamination Versatile, adjustable test torch available Remote self test facility Microprocessor controlled E Immunity to false sources (arc welding, lightning and static) E Conforms to EN54: Part 10 Flame Detectors Page : 30 UV/IR universal test torch FF703 A microproccessor universal test torch that can test all FF700 series flame detectors. It emits various channels of infra-red to test dual IR detectors. It also can emit 'flickering' IR to test for false alarms. Ordering Information FF703 UV/IR universal test torch Adjustable mounting bracket A universal swivel mounting bracket for most FF700 flame detectors. Ordering Information FF705 Adjustable mounting bracket FF705 Flame Detectors Page : 31 Stainless steel weather shield A weather shield that can be used for most FF700 flame detectors Ordering Information FF706 Stainless steel weather shield FF706 Beam Detectors Page : 32 FD2000 Beam smoke detector 10 - 100m FD2000 Series The unit consists of an infrared transmitter, a receiver and a control unit. The unit is particularly designed to be used where point smoke detectors are not applicable due to height or inaccessibility. The control unit has C/O relay outputs for alarm and fault and fits as such all types of fire panels. Specifications Supply Voltage 11.5 - 28 VDC Current consumption Quiscent less than 13 mA Alarm less than 20 mA Operating Temperature -20 to 55 °C Size Control Unit 210 x 160 x 80 mm Heads 83 x 115 x 135 mm IP Rating Control Unit IP 50 Heads IP 50 Construction Control Unit Double pressed steel sheet Heads Zinc alloy Colour Control Unit White RAL 9010 Heads White RAL 9010 Certification VdS Ordering Information FD2000 Beam smoke detector 10 - 100m FD2010 Beam smoke detector 10 - 100m, flame proof E E E E E E E E E E E E E E E Large area coverage up to 1500 m² per unit Range from 10 to 100m Up to ceiling heights of 25 m 12 to 24 VDC Low current consumption Manual or automatic reset 3 selectable alarm thresholds Self check and automatic signal compensation Automatic discrimination between fire and fault Retro operation through prisms Ground level electronics Easy wiring and alignment Conforms to BS5839 part 5 VdS approved Atex flame-proof version Beam Detectors Page : 33 FD705R Reflective beam smoke detector 5 - 50m FD700 Series The FD 705R and FD 710R consists of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be used where point smoke detectors are not applicable due to height or inaccessibility. The unit has C/O relay outputs for alarm and fault and fits as such all types of fire panels. The FD 705R has a range of 5-50 m and the FD 710R has a range of 50-100 m. Specifications Supply voltage 10.2 - 30 V dc Range FD 705R 5 - 50 m FD 710R 50 - 100 m Lateral detection 7.5 m Current consumption Quiescent < 4 mA Alarm < 15 mA Optical wave length 880 nm Operating temperature -30°C to 55°C Size 210 x 130 x 120 mm IP rating IP50 Construction Flame retardent ABS Colour Gray-black Ordering Information FD705R Reflective beam smoke detector 5 - 50m FD710R Reflective beam smoke detector 50 - 100m E E E E E E E E E E E E E E E Area coverage up to 600 m 2 per unit Range from 5 - 50 m and 50 - 100 m Up to ceiling heights of 25 m 10 to 30 V dc operation Low current consumption Manual or automatic reset 3 selectable alarm thresholds Self check and automatic contamination compensation Automatic discrimination between fire and fault Retro operation through prism Vertical or horizontal mount Easy wiring and unique alignment Microprocessor controlled EN54 approved VDS and UL certified Beam Detectors Page : 34 FD710R Reflective beam smoke detector 50 - 100m FD700 Series The FD 705R and FD 710R consists of an infrared transmitter and receiver in one single compact housing. The infrared signal is reflected by a prism and analysed for smoke presence. It is particularly designed to be used where point smoke detectors are not applicable due to height or inaccessibility. The unit has C/O relay outputs for alarm and fault and fits as such all types of fire panels. The FD 705R has a range of 5-50 m and the FD 710R has a range of 50-100 m. Specifications Supply voltage 10.2 - 30 V dc Range FD 705R 5 - 50 m FD 710R 50 - 100 m Lateral detection 7.5 m Current consumption Quiescent < 4 mA Alarm < 15 mA Optical wave length 880 nm Operating temperature -30°C to 55°C Size 210 x 130 x 120 mm IP rating IP50 Construction Flame retardent ABS Colour Gray-black Ordering Information FD710R Reflective beam smoke detector 50 - 100m FD705R Reflective beam smoke detector 5 - 50m E E E E E E E E E E E E E E E Area coverage up to 600 m 2 per unit Range from 5 - 50 m and 50 - 100 m Up to ceiling heights of 25 m 10 to 30 V dc operation Low current consumption Manual or automatic reset 3 selectable alarm thresholds Self check and automatic contamination compensation Automatic discrimination between fire and fault Retro operation through prism Vertical or horizontal mount Easy wiring and unique alignment Microprocessor controlled EN54 approved VDS and UL certified Linear Heat Detection System Page : 35 DT650L Conventional controller for analogue linear heat cable The DT650L and DT950L controllers are especially designed to provide the best response with the HC600 series analogue linear heat sensing cable. The DT650L conventional controller provides a fire and fault relay output, and operates with 18 - 30 Volt dc. The unit has an IP65 rating. The DT650L is VDS approved when used with the HC600 series analogue linear heat cable, and provides class C or class D heat monitoring. Specifications Operating voltage range Volt dc 18-30 Operating current (typical) mA Quiescent 28 Alarm 58 Operating temperature °C -25 to +50 Relay contact rating (fire and fault) 1 A @ 30 V dc IP rating IP65 Dimension (H x Wx D in mm) Controller 105 x 105 x 65 Termination box 80 x 80 x 52 Colour Grey, RAL 9002 Ordering Information DT650L HC650 HC650R HC650S HC650RS DT950L Conventional controller for analogue linear heat cable Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, stainless steel covering - 500 m Analogue linear heat cable, Rilsan + stainless steel - 500 m 950 series addressable controller for analogue linear heat cable E Conventional controller E Designed for the HC600 series analogue linear heat cable E E E E E Fire and fault relay output Ease of installation 18 to 30 Volt operation IP65 VdS approved Linear Heat Detection System Page : 36 DT950L 950 series addressable controller for analogue linear heat cable The DT650L and DT950L controllers are especially designed to provide the best response with the HC600 series analogue linear heat sensing cable. The DT950L analogue addressable controller is connected to the loops of the FP1200 / FP2000 series analogue addressable fire panels and operates with 950 series protocol. The unit is loop powered, and the fire and fault status is shown directly on the fire panel LCD screen The DT950L is VDS approved when used with the HC600 series analogue linear heat cable, and provides class C or class D heat monitoring. Specifications Operating voltage range Volt dc 18-30 Operating current (typical) mA Quiescent 2 Alarm 3.2 Operating temperature °C -25 to +50 Relay contact rating (fire and fault) - IP rating IP65 Dimension (H x Wx D in mm) Controler 105 x 105 x 65 Termination box 80 x 80 x 52 Colour Grey, RAL 9002 Ordering Information DT950L HC650 HC650R HC650S HC650RS DT650L 950 series addressable controller for analogue linear heat cable Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, stainless steel covering - 500 m Analogue linear heat cable, Rilsan + stainless steel - 500 m Conventional controller for analogue linear heat cable E E E E E E E Analogue addressable controllers Designed for the HC600 series analogue heat cable Ease of installation Loop powered 950 series protocol FP1200 / FP2000 operation VdS approved Linear Heat Detection System Page : 37 HC650 Analogue linear heat cable, PVC - 500 m The HC650 PVC cable is suitable for indoor, non corrosive applications. The cable is also available in other outer sheaths: Rilsan covered for protection from chemicals, stainless steel covered for mechanical strength, and stainless steel plus Rilsan covered for mechanical and chemical protection. The HC600 series of analogue linear heat cable can be used in many applications not suitable for conventional heat detectors. The cable is particularly suitable for applications such as coal conveyors, power cable tunnels, and cable trays. A rapid response to temperature conforming to heat class C or D operation is obtained when using the DT650L or DT950L cable controllers. The system is VDS approved using these controllers. Specifications 1m alarm temp °C 70-125 10m alarm temp °C 45-100 Operating temp °C -20 to +70 Maximum length per controller 300 m Maximum operating ambient temp 40 °C Outer sheath material Red PVC Dimensions (diameter in mm) 2.8 Ordering Information HC650 HC650R HC650S HC650RS DT650L DT950L HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, stainless steel covering - 500 m Analogue linear heat cable, Rilsan + stainless steel - 500 m Conventional controller for analogue linear heat cable 950 series addressable controller for analogue linear heat cable 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack E E E E E E E E Analogue linear heat cable Conventional and analogue addressable controllers Monitoring at the point of risk Ease of installation Reliable and durable Cable re-usable after alarm Ideal for 'smokeless' fires - overheating cables Class C or class D heat grade E VdS approved when using the DT650L and DT950L controllers Linear Heat Detection System Page : 38 HC650R Analogue linear heat cable, Rilsan coating - 500 m The HC650 Rilsan coated cable is suitable for protection from chemicals. The cable is also available in other outer sheaths: PVC covered for indoor non-corrosive conditions, stainless steel covered for mechanical strength, and stainless steel plus Rilsan covered for mechanical and chemical protection. The HC600 series of analogue linear heat cable can be used in many applications not suitable for conventional heat detectors. The cable is particularly suitable for applications such as coal conveyors, power cable tunnels, and cable trays. A rapid response to temperature conforming to heat class C or D operation is obtained when using the DT650L or DT950L cable controllers. The system is VDS approved using these controllers. Specifications 1m alarm temp °C 70-125 10m alarm temp °C 45-100 Operating temp °C -20 to +70 Maximum length per controller 300 m Maximum operating ambient temp 40 °C Outer sheath material Rilsan coated Dimensions (diameter in mm) 4 Ordering Information HC650R HC650 HC650S HC650RS DT650L DT950L HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, stainless steel covering - 500 m Analogue linear heat cable, Rilsan + stainless steel - 500 m Conventional controller for analogue linear heat cable 950 series addressable controller for analogue linear heat cable 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack E E E E E E E E Analogue linear heat cable Conventional and analogue addressable controllers Monitoring at the point of risk Ease of installation Reliable and durable Cable re-usable after alarm Ideal for 'smokeless' fires - overheating cables Class C or class D heat grade E VdS approved when using the DT650L and DT950L controllers Linear Heat Detection System Page : 39 HC650S Analogue linear heat cable, stainless steel covering - 500 m The stainless steel coating gives high mechanical strength. The cable is also available in other outer sheaths: PVC covered for indoor non-corrosive applications, Rilsan covered for protection from chemicals, and Rilsan plus stainless steel covered for mechanical strength and protection from chemicals. The HC600 series of analogue linear heat cable can be used in many applications not suitable for conventional heat detectors. The cable is particularly suitable for applications such as coal conveyors, power cable tunnels, and cable trays. A rapid response to temperature conforming to heat class C or D operation is obtained when using the DT650L or DT950L cable controllers. The system is VDS approved using these controllers. Specifications 1m alarm temp °C 70-125 10m alarm temp °C 45-100 Operating temp °C -20 to +70 Maximum length per controller 300 m Maximum operating ambient temp 40 °C Outer sheath material Stainless steel Dimensions (diameter in mm) 3.5 Ordering Information HC650S HC650 HC650R HC650RS DT650L DT950L HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 Analogue linear heat cable, stainless steel covering - 500 m Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, Rilsan + stainless steel - 500 m Conventional controller for analogue linear heat cable 950 series addressable controller for analogue linear heat cable 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack E E E E E E E E Analogue linear heat cable Conventional and analogue addressable controllers Monitoring at the point of risk Ease of installation Reliable and durable Cable re-usable after alarm Ideal for 'smokeless' fires - overheating cables Class C or class D heat grade E VdS approved when using the DT650L and DT950L controllers Linear Heat Detection System Page : 40 HC650RS Analogue linear heat cable, Rilsan + stainless steel - 500 m The Rilsan plus stainless steel covering gives mechanical strength and chemical resistance. The cable is also available in other outer sheaths: PVC covered for indoor non-corrosive applications, Rilsan covered for protection from chemicals, and stainless steel covered for mechanical strength. The HC600 series of analogue linear heat cable can be used in many applications not suitable for conventional heat detectors. The cable is particularly suitable for applications such as coal conveyors, power cable tunnels, and cable trays. A rapid response to temperature conforming to heat class C or D operation is obtained when using the DT650L or DT950L cable controllers. The system is VDS approved using these controllers. Specifications 1m alarm temp °C 70-125 10m alarm temp °C 45-100 Operating temp °C -20 to +70 Maximum length per controller 300 m Maximum operating ambient temp 40 °C Outer sheath material Rilsan and Stainless steel Dimensions (diameter in mm) 4.5 Ordering Information HC650RS HC650 HC650R HC650S DT650L DT950L HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 Analogue linear heat cable, Rilsan + stainless steel - 500 m Analogue linear heat cable, PVC - 500 m Analogue linear heat cable, Rilsan coating - 500 m Analogue linear heat cable, stainless steel covering - 500 m Conventional controller for analogue linear heat cable 950 series addressable controller for analogue linear heat cable 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack E E E E E E E E Analogue linear heat cable Conventional and analogue addressable controllers Monitoring at the point of risk Ease of installation Reliable and durable Cable re-usable after alarm Ideal for 'smokeless' fires - overheating cables Class C or class D heat grade E VdS approved when using the DT650L and DT950L controllers Linear Heat Detection System Page : 41 HCD607 Digital heat sensing cable 68°C - 500 m The digital linear heat cable is suitable for many applications where conventional heat detectors cannot be used. The cable is particularly suitable for applications such as coal conveyors, power cable tunnels, cable trays, and petro-chemical floating roof tanks. The digital cable is approved for outdoor use. Digital linear heat cable is particularly suitable for intrinsic safe solutions using a zener barrier. Five different alarm temperatures from 68°C to 235°C are available. Using simple application and installation manuals, the correct cable can be installed to provide rugged, reliable heat detection at the point of risk. Properly installed, the digital linear heat detection system is maintenance free. Specifications Max operating voltage 100 V ac/dc Conductor resistance 100 Ohm/km Alarm temp °C 68 Max ambient °C 45 Outer sheath material Polythene Braid Colour/Marking Red/Green tracer Dimensions (diameter in mm) 3.65 Ordering Information HCD607 HCD609 HCD610 HCD618 HCD623 HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 Digital heat sensing cable 68°C - 500 m Digital heat sensing cable 88°C - 500 m Digital heat sensing cable 105°C - 500 m Digital heat sensing cable 180°C - 500 m Digital heat sensing cable 235°C - 500 m 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack E E E E E E E Digital linear heat cable Monitoring at the point of risk Choice of temperatures 68 to 235°C Ease of installation Reliable and durable Intrinsic safe solutions Ideal for 'smokeless' fires - overheating cables Linear Heat Detection System Page : 42 'A' clip for heat cable 100/pack HCA601 Manufactured from nylon with M6 fixing holes complete with cable tie. Ideal for installation where heat transfer from the fixing point to the heat sensing cable must be minimised. The fixing screw is not included. The A clip is 27mm long, 16mm high, and 12mm wide. Ordering Information HCA601 HCA602 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack 'P' clip for heat cable 100/pack Zinc plated steel clip with santoprene cushion insulator. The fixing screw is not included. This 'P' clip provides insulation from electrical earth, which is often needed for stainless steel sheath cable. The clip is 12,7mm from the cable centre to the mounting hole. Ordering Information HCA602 HCA601 HCA603 HCA605-3 HCA605-8 HCA605-14 HCA605-20 'P' clip for heat cable 100/pack 'A' clip for heat cable 100/pack 'T' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack HCA602 Linear Heat Detection System Page : 43 'T' clip for heat cable 100/pack HCA603 CEILING or WALL ‘T’ CLIPS For space protection applications the ideal location for the heat sensing cable is on the ceiling or the top of the side wall. This ensures that the cable is rapidly exposed to the plume of hot gases from any event that rise and spread across the ceiling. The 20mm stand off provided by the clip is necessary as a layer of colder air is often trapped against the ceiling in a fire condition. The clip is a plastic moulding with a slot into which the heat sensing cable is located, for extra security a tie wrap may be used in a figure “8” arrangement to prevent the cable from being pulled from the clip. In general one clip should be used every metre however two clips should be mounted close together at 90 degrees where the cable route changes direction. The clip may be secured with a screw and wall plug or may be screwed on to an M6 thread on a percussion pin. Ordering Information HCA603 HCA601 HCA602 HCA605-3 HCA605-8 HCA605-14 HCA605-20 'T' clip for heat cable 100/pack 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack Edge clip for heat cable 2-3 mm 100/pack To fit structures from 2 to 3 mm The knock on edge clip is available to mount on steelwork of differing thickness and provides a stand-off for the linear heat sensing cable to ensure rapid response. These fixings are made of mild steel with a zinc rich plated finish. This has excellent resistance to corrosion and heat. The linear heat sensing cable should always be secured to the edge clip with the recommended neoprene sleeve and tie wrap. Ordering Information HCA605-3 HCA605-8 HCA605-14 HCA605-20 HCA601 HCA602 HCA603 Edge clip for heat cable 2-3 mm 100/pack Edge clip for heat cable 3-8 mm 100/pack Edge clip for heat cable 8-14mm 100/pack Edge clip for heat cable 14-20mm 100/pack 'A' clip for heat cable 100/pack 'P' clip for heat cable 100/pack 'T' clip for heat cable 100/pack HCA605-3 Gas Detection Page : 44 KM260/1R3-03 CO detection control panel - 1 Zone (English Version) The KM-Series CO detection system is designed for applications such as vehicle parking areas where concentrations of CO may accumulate. The range is compliant with the UNE23.300/84 standard. The KM260/1 is a 1 (upgradable to 2) zone control unit, using KM170 detectors. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 2 Mechanical Housing (w x h x d) 275 x 335 x 130 mm Weight 6 kg Ordering Information KM260/1R3-03 CO detection control panel - 1 Zone (English Version) E E E E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area From 1 to 5 areas 3-wire system Modular design Up to 15 detectors per zone 10 seconds response time Elegant design Supervision of all zone lines Available in various languages Gas Detection Page : 45 KM260/3R3-03 CO detection control panel - 3 Zones (English Version) The KM-Series CO detection system is designed for applications such as vehicle parking areas where concentrations of CO may accumulate. The range is compliant with the UNE23.300/84 standard. The KM260/3 is a 3 (upgradable to 5) zone control unit, using KM170 detectors. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 5 Mechanical Housing (w x h x d) 470 x 335 x 130 mm Weight 10.2 kg Ordering Information KM260/3R3-03 CO detection control panel - 3 Zones (English Version) E E E E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area From 1 to 5 areas 3-wire system Modular design Up to 15 detectors per zone 10 seconds response time Elegant design Supervision of all zone lines Available in various languages Gas Detection Page : 46 KM260EXT3-03 CO detection expansion module (English Version) The KM260 is an expansion module for the KM260-Series CO panels from GE-Interlogix. It allows for an additional monitoring zone to be added to the control panel, each module allowing for an additional 15 sensors to be connected. Specifications Power supply Mains supply 230 VAC ±10% 50 Hz Power consumption 95 W (max) Zone configuration Zone input voltage 10-20 VDC/VAC Sensitiviy 0-300 ppm Cable requirement 3 core 1.5 mm² Cable length (max) 350 m No. of detectors (max) 15 No. of zones (max) 1 Ordering Information KM260EXT3-03 CO detection expansion module (English Version) E E E E E E E E E E E E E Designed according to norm 23300/84 Miner CDM8001 and CDM8002 standard password LGAI 154.909 and 96013132 standard certification Easy to use Low current consumption Direct reading of measured levels Easy installation Extraction relays and alarm outputs per area 3-wire system Up to 15 detectors per zone 10 seconds response time Supervision of zone line Available in various languages Gas Detection Page : 47 Blanking plate for KM260 panels The blanking plate is used on KM260 panels during upgrading of modules to cover up any unused positions that may exist on the panel. Ordering Information KM260C Blanking plate for KM260 panels KM260C Gas Detection Page : 48 KM170 CO detector with base and mounting supplement The KM170 detector is specifically designed to react to the presence of carbon monoxide. The design complies with the requirements of the UNE 23-300 standard. Specifications Sensor type TGS semicondictor Useful life 4 years Electrical characteristics Supply voltage 10 to 20 VDC Quiescent current 35 mA Reaction time 10 s Environmental Operating temperature 0 °C to +40 °C Protection index IP205 Mechanical Size (h x Ø) 81 x 109 mm Weight 115 g Material and colour ABS white Installation Number of detectors per zone 15 Covarage 300 m² Ordering Information KM170 CO detector with base and mounting supplement E Complies with the requirements of the UNE23-300 standard E E E E Microprocessor based Resolution of up to 5 ppm Response time of 10 s Low current consumption E Local status indication of: -Normal operation -50ppm detected -Fault E Useful life of up to 4 years Manual Call Points Page : 49 DM700 Manual call point, flying leads, red DM700 Series A red EN54 part 11 approved manual call point with flying leads that can be flush mounted or surface mounted using a back-box Specifications Material Self-extinguishing Noryl SE100 Max. contact rate resistive load 50 V ac or 30 V dc 8A 50 V dc 3A Contact resistance Max. 50 milliohm Series resistor - Colour Red - RAL N°3020 Operating temperature -40° to +85°C Relative humidity max. 90% RV Ordering Information DM700 DM711 DM715 DM800 DM787 DM782 DM784 Manual call point, flying leads, red Break glass, EN54, Aritech logo EN54 universal glass for manual call point Resettable element for MCP DM700/KAL450 Surface mounting box with connectors, red Hinged transparent MCP protection cover Test key E E E E E E E E E E Easy to install With break glass or resettable Easy to replace glass Surface and flush mounting options High quality micro switch Glass protected with foil Standard EN54 symbol Accepts hinged cover as standard Key test facility EN54 part 11 approved Manual Call Points Page : 50 DM700E Surface mount manual call point IP67, red DM700 series A surface mounting manual call point with IP67 rating. Specifications Material - standard Self-extinguishing Noryl SE 100 Max. contact rate resistive load 50 V ac or 30 V dc 8.0 A 50 V dc 3.0 A Contact resistance Max. 50 milliohms Standard colour Red - RAL Nº 3020 Ambient temperature range -40º to + 85º C Maximum relative humidity 90% RV Ordering Information DM700E DM711 DM715 DM800 DM782 DM784 Surface mount manual call point IP67, red Break glass, EN54, Aritech logo EN54 universal glass for manual call point Resettable element for MCP DM700/KAL450 Hinged transparent MCP protection cover Test key E E E E E E E Easy to install With break glass or resettable Easy to replace glass High quality micro switch Back box included IP67 EN54 part 11 approved Manual Call Points Page : 51 DM700IS Intrinsic safe manual call point, including back box DM700 series An intrinsic safe, weatherproof, ATEX approved manual call point. A back-box and glass is included Specifications Material - standard Glass reinforced polycarbonate Contact resistance Max. 50 milliohms Standard colour Red - RAL Nº 3020 Ambient temperature range -55º to + 55º C Maximum relative humidity 90% RV Ordering Information DM700IS DM711 DM715 DM800 Intrinsic safe manual call point, including back box Break glass, EN54, Aritech logo EN54 universal glass for manual call point Resettable element for MCP DM700/KAL450 E E E E E E E E E E Easy to install EExia IIC T4 Intrinsic safe ATEX approved Ex II 1 G IP66 and IP67 Easy to replace glass Surface mounting High quality micro switch Glass protected with foil Preformed mounting slots Key test facility Manual Call Points Page : 52 DM700K Manual call point with keyswitch, flying leads, red DM700 Series A high quality key switch, installed in a call point plastic, allows on / off control of equipment such as ventilation and overrides. The switch has a normally open and normally closed contact. Specifications Material Self-extinguishing Noryl SE100 Max. contact rate resistive load 24 V dc 6A Colour Red - RAL N°3020 Operating temperature -40° to +85°C Relative humidity Max. 90% RV Ordering Information DM700K Manual call point with keyswitch, flying leads, red DM787 Surface mounting box with connectors, red E E E E E E E Easy to install Surface and flush mounting options High quality key switch Normally open and normally closed contact Operates after long period of disuse Preformed mounting slots EN54 'burning house' label Manual Call Points Page : 53 DM711 Break glass, EN54, Aritech logo DM700 series A standard EN54 break glass for the DM700 series of call points, with Aritech logo Ordering Information DM711 Break glass, EN54, Aritech logo DM715 EN54 universal glass for manual call point DM800 Resettable element for MCP DM700/KAL450 E E E E Plastic coated to prevent operator injury No glass fragments on breaking No hammer required Approved EN54 part 11 DM715 EN54 universal glass for manual call point The DM715 is a universal EN54 approved break glass for the DM700 series and KAL450 manual call points. Ordering Information DM715 EN54 universal glass for manual call point DM800 Resettable element for MCP DM700/KAL450 E E E E Plastic coated to prevent operator injury No glass fragments on breaking No hammer required Approved EN54 part 11 Manual Call Points Page : 54 DM782 Hinged transparent MCP protection cover The DM782 anti-tamper plastic cover is a protection cover for the DM700 and KAL450 manual call points. It prevents accidental activation of the alarm by enforcing a two step action i.e. lifting the cover, then activating the alarm. Ordering Information DM782 Hinged transparent MCP protection cover DM798 Breakable seal for MCP E Unobtrusive E Transparent E Protects from accidental alarm activation DM787 Surface mounting box with connectors, red The DM787 is surface mounting back-box for DM700 series and KAL450 series manual call points. The DM787 is red and has 3 wiring terminals Specifications Material Self-extinguishing Noryl SE100 Colour Red - RAL N°3020 Operating temperature -40° to +85°C Relative humidity max. 90% RV Ordering Information DM787 DM787Y DM787B DM787G DM788 Surface mounting box with connectors, red Surface mounting box with connectors, yellow Surface mounting box with connectors, blue Surface mounting box with connectors, green Surface mount box without connectors, red E Easy to install E For flush mounting of manual call points E Three terminals Manual Call Points Page : 55 DM788 Surface mount box without connectors, red A red back-box for the surface mounting of DM700 series of manual call points, without connectors. Specifications Material Self-extinguishing Noryl SE100 Colour Red - RAL N°3020 Operating temperature -40° to +85°C Relative humidity max. 90% RV Ordering Information DM788 DM788Y DM788B DM788GR DM788W DM787 Surface mount box without connectors, red Surface mount box without connectors, yellow Surface mount box without connectors, blue Surface mount box without connectors, green Surface mount box without connectors, white Surface mounting box with connectors, red E Easy to install E For flush mounting of manual call points Conventional Fire Systems Page : 56 PK20 Resetable Manual Call Point General The PK20 manual call point is a manual alarm activation point for conventional detection systems. Once activated, it remains activated until it is manually reset using a key. To reset, simply turn the key a ¼ turn to the right and it is ready for use. This call point has been designed for indoor use. Specifications Size 100 x 95 x 43 mm Max. recommended distance between units 60 m Installation height 1.2 - 1.5m Fastening screws 2x (3.5 x 30 mm) Power supply voltage 24 VDC Consumption in standby 0 mA Consumption in alarm 60 mA Status Indications Standby, Alarm Working temperature -10° to 50°C Storage temp. -10° to 50°C Max. relative humidity 95% Ordering Information PK20 Resetable Manual Call Point PK20M Flush mount cradle PK20TC Hinged transparent MCP protection cover for PK20 E E E E E E E E Standard labelling (pictograms) Spare crystals not required Easy installation Easy maintenance Accessory for flush mount (optional) Transparent protection cover (optional) For conventional systems Modern, robust and elegant design Conventional Fire Systems Page : 57 PK20M Flush mount cradle Accessory for PK20 resetable manual callpoint. This cradle allows for the PK20 to be flush mounted. Ordering Information PK20M Flush mount cradle E Allows flush mounting of the PK20 manual call point PK20TC Hinged transparent MCP protection cover for PK20 Accesory for PK20 resetable manual callpoints. Made of transparent plasic, it prevents the manual call point from being accidentally activated. Ordering Information PK20TC Hinged transparent MCP protection cover for PK20 E Unobtrusive E Transparent E Protects from accidental alarm activation Annunciators Page : 58 Mini disc remote indicator This low current remote indicator can be used with all 650, 950, 700 & 2000 series detectors, and can also be used in intrinsic safe applications. Ordering Information AI671 Mini disc remote indicator AI671 Annunciators Page : 59 AI672 Optical Remote Indicator Specifications Material Self-extinguishing polycarbonate Dimensions (L x W x H) 80 x 80 x30 mm Colour White RAL 9010 Operating voltage 12-28 V dc Current consumption 4 mA nominal Flashing frequency ± 1.3 Hz Light intensity 200 mcd Colour LED's RED Ordering Information AI672 Optical Remote Indicator E E E E E E E E E E Wide operating voltage Low current consumption Universal mounting plate Low profile Clearly visible, large LEDs Protected against polarity reversal Connects up to 4 detectors Blinking or fixed LEDs High sound output With and without sounder Annunciators Page : 60 AI673 Optical and Accustical Remote Indicator Specifications Material Self-extinguishing polycarbonate Dimensions (L x W x H) 80 x 80 x 30 mm Weight ± 55 g Colour White RAL N° 9010 Surface Textured Terminals 5 Operating Voltage 12 - 28 V dc Current consumption 4 mA nominal Flashing frequency ± 1.3 Hz Light intensity 200 mcd Colour LED's Red Sound pressure 81 dBA 1 metre Frequency ± 3600 Hz Ordering Information AI673 Optical and Accustical Remote Indicator E E E E E E E E E E Wide operating voltage Low current consumption Universal mounting plate Low profile Clearly visible, large LEDs Protected against polarity reversal Connects up to 4 detectors Blinking or fixed LEDs High sound output With and without sounder Annunciators Page : 61 KR24B Illuminated warning sign (No text) 24VDC The KR24 is specifically designed as an evacuation warning sign for gas extinguising areas. The KR24B has no text on the backlit display, and text may therefor be added as required for the application. Units supplied with text in various languages are also available. Specifications Electrical Specifications Supply Voltage 18 to 27 VDC Activation Voltage 18 to 27 VDC Current Consumption 600 mA Switching Polarity NA Indicators 24 V 3 W Environmental Specifications Working Temperature -10 to 75 °C Physical Specifications Number of zones NA Buzzer output 80 dB Housing Colour Grey Display Colour Red Weight 700 g Size (w x h x d) 255 x 110 x 50 mm IP Rating IP50 Ordering Information KR24B Illuminated warning sign (No text) 24VDC E E E E Low current consumption Large angle of view Optical and acoustic indications selectable Modern and elegant design Annunciators Page : 62 PA25/3L Low current remote LED indicator The PA25 remote indicators have been designed for direct connection to fire detectors (conventional and analogue), enabling luminous indication outside the area where the detector is installed. Specifications Electrical Specifications Supply Voltage (Analogue) 5 to 10 VDC Current Consumption 2 to 79 mA Supply Voltage (Conventional) 2 to 5 VDC Current Consumption 6.5 to 61.5 mA Mechanical Specifications Size (w x h x d) 80 x 80 x 42 mm Weight 10 g Box material A.B.S. Colour White Environmental Specifications Protection level IP20 Working temperature -10 to +60 °C Storage temperature -10 to +70 °C Ordering Information PA25/3L Low current remote LED indicator E E E E E E E E E Direct two-wire connection to detector Large angle of visibility - lit up on four sides Low current consumption Flashing option 2 to 10 VDC power supply High luminosity Compatible with third party products IP20 protection level Modern and elegant design E ABS plastic casing with ruby red polycarbonate spy-hole E Shock resistant Annunciators Page : 63 AS262 Compact panel mount sounder The AS262 is a compact high output, low current sounder ideal for hotels and hospitals. It is available for panel mounting and provides alarm signals for a wide variety of fire, commercial and industrial signalling applications. Specifications Operation Supply voltage 9 - 28 VDC Current consumption (see tone table in manual) 18 mA @ 24 VDC Starting current Sound output @ 1 metre 92 dB(A) @ 24 VDC Number of tones 32 Frequency stability Automatic synchronisation Line monitoring input Housing Red or white ABS Ingress protection IP65 Operating temperature -25 to +70°C Dimensions (Ø x D) 50 mm x 45 mm Weight 95 g Ordering Information AS262 Compact panel mount sounder E E E E E E E Low current consumption High sound output 32 Tones user selectable Available in panel and flange mount Red or white body colour Automatic synchronisation Volume control Annunciators Page : 64 AS263 Sounder, 32 tones - shallow base - RED The AS263 is the industry standard for fire alarm sounders. Its high specification and proven reliability make it the natural choice for all general-purpose commercial and industrial applications. The AS263 has a RED sounder body. Specifications Operation Continuous Supply voltage 9 - 28 VDC Current consumption (see tone table in manual) 16 mA @ 24 VDC Starting current 30 mA, 2 ms Sound output @ 1 metre 102dB(A) at 24Vdc Number of tones 32 Frequency stability Automatic synchronisation Phased start Line monitoring input Polarised input Housing ABS plastic Lens - Ingress protection IP65 Operating temperature -25°C to +70°C Dimensions (Ø x D) Shallow base 93 x 63 mm Deep base - Weight 240 g Ordering Information AS263 AS263IS AS263NF AS263VDS AS263W AS263WAT Sounder, 32 tones - shallow base - RED AS263 intrinsically safe, weatherproof sounder Sounder, 32 tones - shallow base - CNPP approved Sounder, 32 tones - shallow base - VdS approved Sounder, 32 tones - shallow base - WHITE AS263, white with anti-tamper E E E E E E High sound output Low current consumption 32 Tones user selectable Automatic syncronisation Volume control Deep and shallow base versions Annunciators Page : 65 AS264 Sounder, 26 tones - deep base - RED The AS263 is the industry standard for fire alarm sounders. Its high specification and proven reliability make it the natural choice for all general-purpose commercial and industrial applications. The AS264 is the deep base version of the AS263, and has a RED sounder body. Specifications Operation Continuous Supply voltage 10 - 28 V dc Current consumption (see tone table in manual) Starting current 7 mA 30 mA - 2 ms Sound output @ 1 metre Number of tones 26 Frequency stability Automatic synchronisation Phased start Line monitoring input Polarised input Housing ABS plastic Lens Ingress protection IP 65 Operating temperature -25° to +80° C Dimensions in mm (Ø x D) Shallow base 93 x 75 mm Deep base 93 x 105 mm Weight Ordering Information AS264 Sounder, 26 tones - deep base - RED AS264M AS264 mains powered 230 VAC AS264W Sounder, 26 tones - deep base - WHITE E E E E E E High sound output Low current consumption 32 Tones user selectable Automatic syncronisation Volume control Deep and shallow base versions Annunciators Page : 66 AS266 Combined sounder and beacon, 2 tones, red lens - shallow base Providing an audio-visual warning, the AS266 combines the features of a AS263 electronic sounder with a fully integrated beacon. It is available in 24 VDC versions with a wide range of lens and sounder colour combinations. The AS266 is a RED bodied sounder with a RED beacon in a shallow base version. Specifications Operation Continuous Supply voltage 18 - 30 VDC Current consumption (see tone table in manual) Starting current 68 mA 30 mA, 10 ms Sound output @ 1 metre Number of tones 2 Frequency stability Automatic synchronisation Phased start Line monitoring input Polarised input Housing ABS plastic Lens Polycarbonate Ingress protection IP65 Operating temperature -10°C to +55°C Dimensions (Ø x D) Shallow base 93 x 92 mm Deep base 93 x 121 mm Weight Ordering Information AS266 AS266C AS266W AS266WC Combined sounder and beacon, 2 tones, red lens - shallow base Sounder - beacon, 2 tones, clear lens, shallow base Combined sounder and beacon, 2 tones, red lens - shallow base Sounder - beacon, 2 tones, clear lens, shallow base E E E E E E E E E E E Low current consumption High sound output Multiple tones selection on most models 9-24 VDC and 230 VAC models Automatic synchronisation Suitable for multiple stage evacuation Red and white colour body IP65, intrinsic safe and high output versions Low profile and deep base versions Beacons with intelligent xenon flash A choice of red, clear or blue lenses for beacons Annunciators Page : 67 AS268 Sounder, 4 tones, low profile - low current RED Specifications Operation Continuous Supply voltage 9 - 30 VDC Current consumption (see tone table in manual) 3 mA Starting current Sound output @ 1 metre Number of tones 4 Frequency stability Automatic synchronisation Phased start Line monitoring input Polarised input Housing ABS plastic Lens - Ingress protection IP42 Operating temperature -25°C to +85°C Dimensions (Ø x D) Shallow base 101 x 25 mm Deep base - Weight Ordering Information AS268 Sounder, 4 tones, low profile - low current RED AS268W Sounder, 4 tones, low profile - low current WHITE E E E E E E Low current consumption High sound output Automatic synchronisation Suitable for multiple stage evacuation Red and white colour body Low profile version Annunciators Page : 68 AS269 Sounder, 3 tones - low current, high output RED The AS260 series feature a wide range of sounders and sounder / beacons tailored for every application: stand-alone or in combination with fire detectors. The AS269 is a red coloured, low current, high output sounder with 3 selectable tones. Specifications Operation Continuous Supply voltage 12 - 30 VDC Current consumption (see tone table in manual) 5 mA Starting current Sound output @ 1 metre 100 dB(A) ± 2 dB(A) @ 24VDC Number of tones 3 Frequency stability ± 0.5 % Automatic synchronisation Phased start Line monitoring input Polarised input Housing ABS plastic Lens Ingress protection IP42 Operating temperature -25°C to +70°C Dimensions in mm (Ø x D) Weight 0.212 kg Ordering Information AS269 Sounder, 3 tones - low current, high output RED E E E E E E E E E E E Low current consumption High sound output Multiple tones selection on most models 9-24 VDC and 230 VAC models Automatic synchronisation Suitable for multiple stage evacuation Red and white colour body IP65, intrinsic safe and high output versions Low profile and deep base versions Beacons with intelligent xenon flash A choice of red, clear or blue lenses for beacons Annunciators Page : 69 AF310 Electronic solenoid bell, 24 VDC, red The AF310 is an alarm bell designed for use in fire, security and other installations. The solenoid is integrated with the control circuitry and allows for excellent sound coverage, minimum current consumption and increased reliability. The aesthetic design makes it suitable for all applications. Specifications Power Supply Operating Voltage 18 - 30 VDC Nominal Voltage 24 VDC Nominal Current 30 mA Sound Output 93 - 95dB(A) @ 24 VDC Environmental IP Rating IP41 Operating Temperature -10°C to +55°C Alarm Tones 1 Colour Red Construction Gong Steel Base Polycarbonate Weight 1.1 kg Dimensions 155 mm dia x 85 mm deep Ordering Information AF310 Electronic solenoid bell, 24 VDC, red E E E E High sound output Integrated electronic control circuitry Easy installation with components that clip together No back box required for surface wiring Annunciators Page : 70 SK07 Low consumption multi-tone alarm siren The SK07 multi-tone siren is designed to sound an acoustic alarm inside buildings. This small, low profile siren combines a high sound output with low power consumption. It complies with the requirements of EN 54 part 3. Specifications Electrical Supply Voltage 22 - 26 VDC Alarm current 3 mA at 85 dBA or less than 20 mA at 95 dBA Maximum sound level 95 dBA Working temperature -20 °C to 50 °C Storage temperature -20 °C to 70 °C Maximum relative humidity 95 % (non condencing) Mechanical Dimensions 63 mm (h) x 93 mm Ø Protection Index IP445 Fastening screws 2 x 30 mm Maximum cable section 2.5 mm² Recommended cable size Single core 1.5 mm² Ordering Information SK07 Low consumption multi-tone alarm siren E E E E E E E E E E E E E E Low profile Easy installation Back and side cable entry Polarity sensitive Connection base included Input and output terminals included Acoustic power output selection Up to 95 dBA sound output Eight different alarm tones Automatic tone change Low current consumption Low maintenance IP445 protection level EN54 part 3 compliant Annunciators Page : 71 SK20 Alarm sounder with beacon The SK20 is a general purpose sounder designed as part of a fire detection system. For a fire system to fully comply with the provisions set forth in the regulations for fire fighting installations, following the installation recommendations of the UNE23-007-14 standard is advised. Specifications Electrical Requirements Supply voltage 9 to 30 VDC Consumption @ 24 (tone dependant) 7 to 30 mA Acoustic power output (tone 87 to 112 dBA dependant) Nominal power of strobe 1W Environmental Specification Working temperature -20 to +60 °C Storage temperature -20 to +70 °C Relative humidity < 95% Protection level IP445 Functional Specification Strobe frequency 60 flashes/minute Colour Red RAL3001 Size ( h x Ø ) 80 x 92 mm Weight 180 g Ordering Information SK20 Alarm sounder with beacon E E E E E E E E E E E E 32 different tones Includes flashing beacon Low profile Very low consumption Up to 112 dBA sound output levels IP445 protection level Sound output power selection Input and output terminals provided Easy installation Low maintenance Back and side cable entry Modern and elegant design Annunciators Page : 72 SK40 Alarm sounder with indicator (Spanish Version) The SK40 alarm siren with luminous indicator has been designed specifically for external use. Its main function is to warn people outside a building of the detection of a fire alarm inside the building. The SK40 combines the acoustic and indicator parts in a single housing, and is activated with a single voltage input. Specifications Electrical Specifications Supply Voltage 22 to 28 VDC Alarm Current @ 24V 220 mA Environmental Specifications Ingress Protection IP33 Operating Temperature -20 to 60 °C Storage Temperature -20 to 60 °C Physical Characteristics Dimentions (h x w x d) 297 x 210 x 75 mm Sound Output 105 dB at 1 m Sound Frequency 2.8 to 3.1 kHz ± 3% Cycle Time 1 min ON 1 min OFF Flash Rate 1 flash /s Ordering Information SK40 Alarm sounder with indicator (Spanish Version) E E E E E High sound output Exterior operation Selectable activation times Optional battery backup Optional line supervision PA40 Alarm indicator xenon strobe, 12/24 VDC The PA40 Xenon Strobe has been designed for in and outdoor use. It is available with various colour lenses to suit the application. Specifications Electrical Characteristics Supply Voltage 12/24 VDC Current Consumption (12 VDC) 115 mA ± 20 % Current Consumption (24 VDC) 35 mA ± 25 % Environmental Specifications Operating Temperature -20 °C to +60 °C Operational Specifications Flash rate 60-100 flashes/min @ 20°C Operating life 200 hours Colours Amber, blue, clear, red Dimentions ( h x Ø) 79 x 90 mm Ordering Information PA40 Xenon strobe light E E E E High intensity xenon 12 and 24 VDC operation Low current consumption Low maintenance Annunciators Page : 73 CK406 Fire alarm bell The CK406 electronic fire alarm bell is designed as an acoustic fire annunciator. Thanks to their small dimensions and overall design, they are ideal to install in-doors. The CK406 works with 24 VDC supply and the advantage of having very low current consumption (less than 30 mA). This makes them compatible with all good fire alarm systems on the market. Specifications Electrical Characteristics Supply Voltage 24 VDC Current Consumption 30 mA Physical Characteristics Sound Output 95 dBm Colour Red Weight 0.9 kg Diameter 6" (150 mm) Ordering Information CK406 Fire alarm bell E E E E E E Low current consumption Suitable for indoor use Easy Installation 24 VDC powered Very reliable Low maintenance Door Magnets Page : 74 FE831 Door holder, steel box, surface mount, basic Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 42 Dimensions (mm) 70 x 85 x 40 Keeper plate flat/swivel S Release button - Protection diode - Reverse polarity - Cable entry 2 EN1155 Yes NF61937 - BS5839pt3 - Ordering Information FE831 Door holder, steel box, surface mount, basic E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 75 FE832 Door holder, steel box, surface mount complete Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 42 Dimensions (mm) 70 x 85 x 40 Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity - Cable entry 2 EN1155 Yes NF61937 Yes BS5839pt3 Yes Ordering Information FE832 Door holder, steel box, surface mount complete E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 76 FE835 Door holder, steel square base Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 30 Dimensions (mm) 55 x 55 x 24 Keeper plate flat/swivel F Release button - Protection diode - Reverse polarity - Cable entry - EN1155 Yes NF61937 - BS5839pt3 - Ordering Information FE835 Door holder, steel square base E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 77 FE835VDS Door holder, steel square base, VDS magnet Specifications Volt 24 Power 1.6 Holding force (daN) 70 IP rating 30 Dimensions (mm) 55 x 55 x 24 Keeper plate flat/swivel F Release button - Protection diode Yes Reverse polarity Yes Cable entry 1 EN1155 Yes VDS Coil Yes Ordering Information FE835VDS Door holder, steel square base, VDS magnet E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 78 FE836 Door holder, flush mounting Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 42 Dimensions (mm) 83 x 83 x 35 Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity Yes Cable entry - EN1155 Yes NF61937 Yes BS5839pt3 Yes Ordering Information FE836 Door holder, flush mounting E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 79 FE841 Door holder, reinforced aluminium box Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 42 Dimensions (mm) 83 x 83 x 46 Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity Yes Cable entry 2 EN1155 Yes NF61937 Yes BS5839pt3 Yes Ordering Information FE841 Door holder, reinforced aluminium box E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 80 FE841VDS Door holder, reinforced plastic box, VDS magnet Specifications Volt 24 Power 1.6 Holding force (daN) 70 IP rating 52 Dimensions (mm) 83 x 83 x 46 Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity Yes Cable entry 1 EN1155 Yes VDS Coil Yes Ordering Information FE841VDS Door holder, reinforced plastic box, VDS magnet E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 81 FE845 Door holder, wall mount, reinforced aluminium box Specifications Volt 24 Power 1.6 Holding force (daN) 40 IP rating 42 Dimensions (mm) 80 x 80 x 56 Keeper plate flat/swivel F Release button Yes Protection diode Yes Reverse polarity - Cable entry - EN1155 Yes NF61937 Yes BS5839pt3 Yes Ordering Information FE845 Door holder, wall mount, reinforced aluminium box E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 82 Reinforced aluminium extension for FE845, 40mm FE845-40 Specifications Dimensions (mm) 80 x 80 x 43 Ordering Information FE845-40 Reinforced aluminium extension for FE845, 40mm Reinforced aluminium extension for FE845, 150mm Specifications Dimensions (mm) 115 x 115 x 150 Ordering Information FE845-150 Reinforced aluminium extension for FE845, 150mm FE845-150 Door Magnets Page : 83 Reinforced aluminium extension for FE845, 250mm Specifications Dimensions (mm) 115 x 115 x 250 Ordering Information FE845-250 Reinforced aluminium extension for FE845, 250mm FE845-250 Door Magnets Page : 84 FE848 Door holder, floor mounting, reinforced aluminium box Specifications Volt 24 Power 3 Holding force (daN) 40 IP rating 42 Dimensions (mm) 128 x 110 x 80 Keeper plate flat/swivel F Release button Yes Protection diode Yes Reverse polarity - Cable entry - EN1155 Yes NF61937 Yes BS5839pt3 Yes Ordering Information FE848 Door holder, floor mounting, reinforced aluminium box E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 85 FE851VDS Door holder, universal adjustable tube, 175mm, VDS magnet Specifications Volt 24 Power 1.6 Holding force (daN) 70 IP rating 42 Dimensions (mm) - Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity Yes Cable entry - EN1155 Yes VDS Coil Yes Ordering Information FE851VDS Door holder, universal adjustable tube, 175mm, VDS magnet E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 86 FE852VDS Door holder, universal adjustable tube, 475mm, VDS magnet Specifications Volt 24 Power 1.6 Holding force (daN) 70 IP rating 42 Dimensions (mm) - Keeper plate flat/swivel S Release button Yes Protection diode Yes Reverse polarity Yes Cable entry - EN1155 Yes VDS Coil Yes Ordering Information FE852VDS Door holder, universal adjustable tube, 475mm, VDS magnet E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 87 FE855VDS Door holder, steel square base, IP65, VDS magnet Specifications Volt 24 Power 1.6 Holding force (daN) 70 IP rating 65 Dimensions (mm) - Keeper plate flat/swivel F Release button - Protection diode Yes Reverse polarity Yes Cable entry 1 EN1155 Yes VDS Coil Yes Ordering Information FE855VDS Door holder, steel square base, IP65, VDS magnet E E E E E E Complete range for wall and surface mount Low power - 1,6 W 40 daN holding power standard series 70 daN holding power on VDS coils 100% duty cycle Anti-remnant ejector E Protection diode and reverse polarity protection on most models E Release button on most models E EN and French approvals (see specification) Door Magnets Page : 88 FE858 Door holder, explosion proof The door holding magnets are the result of years of specialised development. Rated just 1,6 W @ 24V DC, this powerful magnet packs a holding power of 50 daN. All magnets have a spring-loaded pin to ensure ejection against remnant magnetism. Specifications Volt 24 Power 1.6 Holding force (daN) 50 IP rating Ex EN1155 ATEX Ordering Information FE858 Door holder, explosion proof E E E E E E E Complete range for wall and surface mount Low power - 1,6 W 50 daN holding power 100% duty cycle Anti-remnant ejector EX version Explosion proof, ATEX approved Test and Service Equipment Page : 89 FG010 Universal detector removal tool on a swing frame Ordering Information FG010 Universal detector removal tool on a swing frame ET010 Fibreglass telescopic pole 1.26 m - 4.5 m ET011 Fibreglass extension tube 1.2 m (maximum 3 per ET010) E Universal removal tool on swing frame -size adjustable to fit most detectors -quick & easy removal of detectors E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m E Canvas carry bag -easy transport of the equipment Test and Service Equipment Page : 90 TR010 Touch sensitive transparent dispenser cup on swing frame Ordering Information TR010 ET010 ET011 SC008 Touch sensitive transparent dispenser cup on swing frame Fibreglass telescopic pole 1.26 m - 4.5 m Fibreglass extension tube 1.2 m (maximum 3 per ET010) Aerosol test Spray for Smoke Detectors E Smoke aerosol dispenser -universal, touch sensitive E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m E Ozone friendly test aerosol -tests ionisation and optical sensors -faster response and clearing times E Canvas carry bag -easy transport of the equipment Test and Service Equipment Page : 91 TH010 Mains operated heat detector test tool on swing frame Ordering Information TH010 Mains operated heat detector test tool on swing frame ET010 Fibreglass telescopic pole 1.26 m - 4.5 m ET011 Fibreglass extension tube 1.2 m (maximum 3 per ET010) E Heat detector tester -230V mains version E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m E Canvas carry bag -easy transport of the equipment Test and Service Equipment Page : 92 TH012 Cordless, battery operated, heat detector on swing frame This state-of-the-art heat detector utilises cross-flow technology for fast, efficient heat detector testing. The battery pack is contained within the test pole Ordering Information TH012 Cordless, battery operated, heat detector on swing frame CB001 Canvas carrying bag for the test and service equipment E Heat detector testers -battery operated E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m -faster response and clearing times E Canvas carry bag -easy transport of the equipment Test and Service Equipment Page : 93 ET010 Fibreglass telescopic pole 1.26 m - 4.5 m Ordering Information ET010 Fibreglass telescopic pole 1.26 m - 4.5 m ET011 Fibreglass extension tube 1.2 m (maximum 3 per ET010) E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m E Canvas carry bag -easy transport of the equipment Test and Service Equipment Page : 94 SC008 Aerosol test Spray for Smoke Detectors A clean synthetic aerosol delivering particles which replicate those found in real smoke. The SC008 aerosol test spray has been especially developed to provide maximum testing efficiency with the least impact on the smoke detector and the environment. The SC008 test scray has optimum performance when used with the TR010 touch-sensitive dispenser. Specifications According to material safety data sheet Ordering Information SC008 ET010 ET011 TR010 Aerosol test Spray for Smoke Detectors Fibreglass telescopic pole 1.26 m - 4.5 m Fibreglass extension tube 1.2 m (maximum 3 per ET010) Touch sensitive transparent dispenser cup on swing frame E E E E E E E E E E E No damage to detector plastics and components Faster response time Faster clearing time and detector reset time Minimum residue Minimum impact to health, safety and environment CFC free Non flammable Oil free Suitable for both photoelectric and ionisation detectors Suitable for most makes of detectors Designed for TR010 touch sensitive dispenser Test and Service Equipment Page : 95 CB001 Canvas carrying bag for the test and service equipment A practical, versatile, and rugged carrying case for the test and maintainence equipment Ordering Information CB001 Canvas carrying bag for the test and service equipment E Canvas carry bag -easy transport of the equipment KP300S Smoke detector test kit The KP300S test kit allows the user to test smoke detectors in locations that can normally not be easily reached. It, to a great extent, eliminates the need for ladders and cherry pickers for testing purposes. Ordering Information KP300S Smoke detector test kit EP300 Extension element for detector test pole (1m) SPN500 Test gas for EP300 test equipment CB001 Canvas carrying bag for the test and service equipment E Smoke aerosol dispenser -universal, touch sensitive E Lightweight telescopic poles -fibreglass -non conductive -provides a reach of up to 9m E Test aerosol -tests ionisation and optical sensors -faster response and clearing times E Optional carry bag -easy transport of the equipment Test and Service Equipment Page : 96 EP300 Extension element for detector test pole (1m) The EP300 is an extension pole for the KP300 detector tester. The poles are non-conductive to provide the safest operation. The extension is a 1m section and extension poles may be added to maximum reach of 9 m. Specifications Length 1m Ordering Information EP300 Extension element for detector test pole (1m) E Lightweight telescopic poles -fibreglass -non conductive -use with tools up to 9m SPN500 Test gas for EP300 test equipment The SPN500 is test gas for EP300 test equipment. It allows for the easy an safe activation of optical and ionisation smoke detectors during testing. Ordering Information SPN500 Test gas for EP300 test equipment E Tests ionisation and optical sensors E Faster response and clearing times Power Supply Page : 97 PM705 EN 54-4 approved, 24 V 5A Intelligent Power Supply VDS certified, EN54 pt4 power supply with intelligent battery charging, monitoring and signaling The PM 705 is a fully featured EN54-4 approved power supply ideal for use in fire system applications. Regulated 27.6 V dc output will source up to 5 A into the load as well as providing up to 1 A for charging the standby batteries. The load output features full electronic short circuit protection under both mains and standby battery operation. Maximum battery life is assured through continuous active battery monitoring with both fast bulk charging and trickle charging depending upon the battery condition. The battery charger circuit is temperature compensated ensuring maximum battery life. Deep discharge protection prevents premature battery failure when operating from standby for extended periods. Specifications INPUT Voltage 230 V ac nominal; +10%,-15% Current 1.5 A maximum for full 5 A load OUTPUT Voltage 27- 28 V dc with mains Load Current 18 - 25 V dc on standby 0 - 5A Ripple 100 mV max Load regulation 5% maximum Overload Electronic shutdown at 7A STANDBY BATTERY Battery capacity Up to 2 x 17Ah series connected Battery charging Constant current 1A charge to 80% Deep discharge protection Float charging to 100% Battery disconnect at 20 V Faulty battery detection Battery disconnect at 19 V Battery monitoring current 1 mA maximum LOCAL INDICATORS LED green Mains present LED amber flashing Battery charger fault SIGNALLING OUTPUTS Remote fault communication 5 A @ 30 V dc C/O contacts Output fail communication 0.5 A @ 30 V dc N/O contact MECHANICAL Size 400 x 420 x 80 mm Weight 9 kg (excluding batteries) Temperature -10 to +40º C (operating) Humidity -20 to +80º C (storage) 95% RH non-condensing Ordering Information PM705 PM701 PM702 PM703 EN 54-4 approved, 24 V 5A Intelligent Power Supply EN 54-4 approved, 24 V 1A Intelligent Power Supply EN 54-4 approved, 24 V 2A Intelligent Power Supply EN 54-4 approved, 24 V 3A Intelligent Power Supply E Approved to EN54-4 E 5 A current to load at 27.6 V dc nominal regulated output E Electronic overload protection E Battery monitor detector: -Battery missing, low battery -Short-circuit or reverse connection E E E E E E E E E Automatic battery switching Deep discharge protection Fault indicator LED Fault Relay output Output sense relay Mains indicator LED Temperature compensated Self contained box houses 17 Ah batteries VDS Certified Power Supply Page : 98 PM831 Boxed power supply, 24VDC 1A The PM831 is a "ready-to-use" power supply. It consists of the power supply module, a transformer and a mains fuse/connector mounted in a steel cabinet. Specifications Input voltage 230 VAC Output voltage 50 Hz ±10% 27.6 VDC Load output 0.5 A Total output 1A Output ripple Max. 50 mVrms Max. battery size 7.2 Ah (x2) Battery recharge time 20 Battery disconnect voltage 19.6 ±0.2 VDC Open collector output Open circuit on Fuse 12/24 V output fault or mains fail - 0 V - 100 mA 1.25 A Fuse 230 VAC input 2A Operating temperature -10 °C to +40 °C Relative humidity 95% Housing (steel) powder coated 1.2 mm Dimensions (W x H x D) 330 x 275 x 80 mm Ordering Information PM831 Boxed power supply, 24VDC 1A E E E E E E E E Fault and mains present indicators Battery disconnect to prevent deep discharge Tamperswitch Fault output Mains and dc fuse Fully compliant with IEC65 Transformers conform to BS145, VDE0550 & UL506 Powder coated steel housing Power Supply Page : 99 PM832 Boxed power supply, 24VDC 2A The PM832 is a "ready-to-use" power supply. It consists of the power supply module, a transformer and a mains fuse/connector mounted in a steel cabinet. Specifications Input voltage 230 VAC Output voltage 50 Hz ±10% 27.6 VDC Load output 1.5 A Total output 2A Output ripple Max. 50 mVrms Max. battery size 7.2 Ah (x2) Battery recharge time 20 Battery disconnect voltage 19.6 ±0.2 VDC Open collector output Open circuit on Fuse 12/24 V output fault or mains fail - 0 V - 100 mA 2A Fuse 230 VAC input 2A Operating temperature -10 to +40°C Relative humidity 95% Housing (steel) powder coated 1.2 mm Dimensions (W x H x D) 330 x 275 x 80 mm Ordering Information PM832 Boxed power supply, 24VDC 2A E E E E E E E E Fault and mains present indicators Battery disconnect to prevent deep discharge Tamperswitch Fault output Mains and dc fuse Fully compliant with IEC65 Transformers conform to BS145, VDE0550 & UL506 Powder coated steel housing Power Supply Page : 100 PM833 Boxed power supply, 24VDC 3A The PM833 is a "ready-to-use" power supply. It consists of the power supply module, a transformer and a mains fuse/connector mounted in a steel cabinet. Specifications Input voltage 230 VAC Output voltage 50 Hz ±10% 27.6 VDC Load output 2A Total output 3A Output ripple Max. 50 mVrms Max. battery size 7.2Ah (x2) Battery recharge time 20 Battery disconnect voltage 19.6 ±0.2 VDC Open collector output Open circuit on Fuse 12/24 V output fault or mains fail - 0 V - 100 mA 3A Fuse 230 VAC input 2A Operating temperature -10 to +40°C Relative humidity 95% Housing (steel) powder coated 1.2 mm Dimensions (W x H x D) 330 x 275 x 80 mm Ordering Information PM833 Boxed power supply, 24VDC 3A E E E E E E E E Fault and mains present indicators Battery disconnect to prevent deep discharge Tamperswitch Fault output Mains and dc fuse Fully compliant with IEC65 Transformers conform to BS145, VDE0550 & UL506 Powder coated steel housing Power Supply Page : 101 PM835 Boxed power supply, 24VDC 5A The PM835 is a "ready-to-use" power supply. It consists of the power supply module, a transformer and a mains fuse/connector mounted in a steel cabinet. Specifications Input voltage 230 VAC Output voltage 50 Hz ±10% 27.6 VDC Load output 4A Total output 5A Output ripple Max. 50 mVrms Max. battery size 7.2 Ah (x2) Battery recharge time 20 Battery disconnect voltage 19.6 ±0.2 VDC Open collector output Open circuit on Fuse 12/24 V output fault or mains fail - 0 V - 100 Ma 5A Fuse 230 VAC input 3.15 A Operating temperature -10 to +40°C Relative humidity 95% Housing (steel) powder coated 1.2 mm Dimensions (W x H x D) 330 x 275 x 80 mm Ordering Information PM835 Boxed power supply, 24VDC 5A E E E E E E E E Fault and mains present indicators Battery disconnect to prevent deep discharge Tamperswitch Fault output Mains and dc fuse Fully compliant with IEC65 Transformers conform to BS145, VDE0550 & UL506 Powder coated steel housing Battery Page : 102 BS122N Sealed Lead-Acid Battery - 12V 2.2Ah Specifications Power supply 12 VDC Nominal capacity 2.2 Ah, 20 h rate Max. charge voltage at +20°C 13.8 VDC Max. charge current 0.69 A Max. discharge current 11.5 A Internal approx. resistance 42 mohm Temperature Charge 0 to 40°C Discharge -15 to +50°C Storage -15 to +50°C Terminal type Fast-on 4.8 mm Material housing ABS Fire retardant - Weight 1.061 kg Dimensions (W x H x D) 178 x 34 x 60 mm VdS approval - Ordering Information BS122N Sealed Lead-Acid Battery - 12V 2.2Ah E E E E E E E Maintenance free Lead-Calcium grid for extended life Wide operating temperature range Usable and rechangeable in any position Low self-discharge and long service life Leakproof construction High discharge rate capacity Battery Page : 103 BS127N Sealed Lead-Acid Battery - 12V 7.2Ah Specifications Power supply 12 VDC Nominal capacity 7.2 Ah, 20 h rate Max. charge voltage at +20°C 13.8 VDC Max. charge current 2.16 A Max. discharge current 35 A Internal approx. resistance 21 mohm Temperature Charge 0 to 40°C Discharge -15 to +50°C Storage -15 to +50°C Terminal type Fast-on 4.8 mm Material housing ABS Fire retardant - Weight 2.678 kg Dimensions (W x H x D) 151 x 94 x 65 mm VdS approval G101120 Ordering Information BS127N Sealed Lead-Acid Battery - 12V 7.2Ah BS127NS3 Sealed Lead-Acid Battery - 12V 7.2Ah E E E E E E E Maintenance free Lead-Calcium grid for extended life Wide operating temperature range Usable and rechangeable in any position Low self-discharge and long service life Leakproof construction High discharge rate capacity Cables Page : 104 KAL21 Fire Alarm Cable 2 x 1.5 mm² (RED) The KAL21 is a single pair, twisted cabe with screen and no sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as DC power carrier or as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-3.1 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Impedance - Test Voltage - Isolation Resistance - Capacitance - Operating Voltage - Ordering Information KAL21 Fire Alarm Cable 2 x 1.5 mm² (RED) E Colours: red-black E Polished copper, flexibility class 5 according to UNE-21.022 E Tape of aluminum MYLAR, polyester and thread with drainage in tin-plated copper KAL21A Fire Alarm Cable 2 x 1.5 mm² (RED) The KAL21A is a single pair, twisted cabe with braided screen and sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-3.1 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Impedance 115 ohm Test Voltage 1500 V Isolation Resistance > 10 000 ohm/km Capacitance - Operating Voltage - Ordering Information E Colours: red-black E Polished copper, flexibility class 5 according to KAL21A Fire Alarm Cable 2 x 1.5 mm² (RED) E Tape of aluminum MYLAR, polyester and thread with UNE-21.022 drainage in tin-plated copper E Compact PVC outer cover in red colour Cables Page : 105 KAL21B Fire Alarm Cable 2 x 2 x 1.5 mm² (RED) The KAL21B is a double pair, twisted cabe with braided screen and sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-2.9 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Impedance 115 ohm Test Voltage 1500 V Isolation Resistance > 10 000 ohm/km Capacitance 86 pF/m at 1 KHz Operating Voltage 24 VDC / 48 VDC Ordering Information KAL21B Fire Alarm Cable 2 x 2 x 1.5 mm² (RED) E Colours: red-black, brown-yellow E Polished copper, flexibility class 5 according to UNE-21.022 E Set tape of polyester with thread and drainage in tin-plated copper with aluminium tape MYLAR E Compact PVC outer cover in red colour KAL51 Fire Alarm Cable (Halogen Free) 2 x 1.5 mm² (RED) The KAL51 is a single pair, halogen free twisted cabe with screen and no sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as DC power carrier or as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-3.1 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Ordering Information KAL51 Fire Alarm Cable (Halogen Free) 2 x 1.5 mm² (RED) E Colours: red-black E Polished copper, flexibility class 5 according to UNE-21.022 E Tape of aluminum MYLAR, polyester and thread with drainage in tin-plated copper E Halogen free Cables Page : 106 KAL51A Fire Alarm Cable (Halogen free) 2 x 1.5 mm² (RED) The KAL51A is a single pair, halogen free, twisted cabe with braided screen and sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-3.1 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Impedance 115 ohm Test Voltage 1500 V Isolation Resistance > 10 000 ohm/km Ordering Information KAL51A Fire Alarm Cable (Halogen free) 2 x 1.5 mm² (RED) E Colours: red-black E Polished copper, flexibility class 5 according to UNE-21.022 E Tape of aluminum MYLAR, polyester and thread with drainage in tin-plated copper E Compact PVC outer cover in red colour E Halogen free Cables Page : 107 KAL51B Fire Alarm Cable (Halogen Free) 2 x 2 x 1.5 mm² (RED) The KAL51B is a double pair, halogen free, twisted cabe with braided screen and sleeve. Its step is formed by more than 25 turns between conductors. It is ideal for use as data bus for access control and fire detection. Specifications Conductor Section 1.5 mm² Aluminum MYLAR 7 * 0.18 mm Conductor diameter 2.8-2.9 mm Resistance < 13.3 ohm/km Operating Temperature -20 °C to +85 °C Impedance 115 ohm Test Voltage 1500 V Isolation Resistance > 10 000 ohm/km Capacitance 86 pF/m at 1 KHz Operating Voltage 24 VDC / 48 VDC Ordering Information KAL51B Fire Alarm Cable (Halogen Free) 2 x 2 x 1.5 mm² (RED) E Colours: red-black, brown-yellow E Polished copper, flexibility class 5 according to UNE-21.022 E Set tape of polyester with thread and drainage in tin-plated copper with aluminium tape MYLAR E Compact PVC outer cover in red colour E Halogen free Content FDD700 FDD700LP FDD700MB ASD20C ASD20F ASD20FIL FASD710 FHSD720 FHSD721 FHSD724D FHSD726 FHSD7215D FHSD720PS FHSD720RL FHSD731 FHSD732 FHSD733 FHSD751 FHSD752 FHSD753 FHSD754 FHSD755 FHSD756 FHSD761 FHSD762 FHSD763 FHSD764 FHSD771 FHSD772 FHSD773 FHSD774 FHSD775 FF711 FF711R FF713 FF716 FF721 FF741 FF751 FF703 FF705 FF706 FD2000 FD705R Single pipe universal duct detector Page : 3 Extra-long sampling pipe for the FDD700 duct detector, 1.5m Page : 4 Mounting bracket for irregular shape and circular ducts Page : 4 Aspiration Smoke Detector Page : 5 Filter housing for ASD20 Page : 6 Filter only for ASD20 Page : 6 High-performance aspiration controller for point detectors Page : 7 Localised aspirated early warning smoke detection system Page : 8 Four pipe, one address aspirated early warning smoke detection system Page : 9 Four channel four area aspirated early warning smoke detection system Page : 10 Six channel six area aspirated early warning smoke detection system Page : 11 15 Channel Micro bore aspirated early warning smoke detection system Page : 12 PSU Batt charger 230V for FHSD721-FHSD7215 Page : 13 Relay Module 4 Channel for FHSD72x Page : 13 Conversion kit for remote display Page : 14 Single channel remote display & programmer Page : 14 Remote display repeater unit - 16 units Page : 15 Filter+ with filter element - harsh environment Page : 15 Filter in-line single stage Page : 16 Filter in-line 3 stage Page : 16 Replacement filter element for the FHSD751 Page : 17 Replacement filter element set - medium / fine for the FHSD753 Page : 17 Replacement filter element pack of 10 - coarse - for the FHSD753 Page : 18 Micro bore 6mm sampling tube - 30 meter reel Page : 18 Straight union for micro bore 6mm tube Page : 19 Tee union for micro bore 6mm tube Page : 19 Scintered end of line filter for micro bore 6mm tube Page : 20 Large bore red pipe 3 metre length Page : 20 Straight union large bore Page : 21 90 deg. bend for large bore pipes Page : 21 45 deg. elbow for large bore pipes Page : 22 End cap for large bore pipes Page : 22 UV flame detector complete with base Page : 23 24 VDC relay base for FF711 Page : 24 UV flame detector self contained with fire and fault relays Page : 25 UV flame detector in flame proof enclosure Page : 26 Dual IR flame detector complete with 2 wire base Page : 27 Dual IR flame detector in glass reinforced polycarbonate housing Page : 28 UV / Dual IR flame detector in die cast zinc alloy housing Page : 29 UV/IR universal test torch Page : 30 Adjustable mounting bracket Page : 30 Stainless steel weather shield Page : 31 Beam smoke detector 10 - 100m Page : 32 Reflective beam smoke detector 5 - 50m Page : 33 FD710R DT650L DT950L HC650 HC650R HC650S HC650RS HCD607 HCA601 HCA602 HCA603 HCA605-3 KM260/1R3-03 KM260/3R3-03 KM260EXT3-03 KM260C KM170 DM700 DM700E DM700IS DM700K DM711 DM715 DM782 DM787 DM788 PK20 PK20M PK20TC AI671 AI672 AI673 KR24B PA25/3L AS262 AS263 AS264 AS266 AS268 AS269 AF310 SK07 SK20 SK40 Reflective beam smoke detector 50 - 100m Page : 34 Conventional controller for analogue linear heat cable Page : 35 950 series addressable controller for analogue linear heat cable Page : 36 Analogue linear heat cable, PVC - 500 m Page : 37 Analogue linear heat cable, Rilsan coating - 500 m Page : 38 Analogue linear heat cable, stainless steel covering - 500 m Page : 39 Analogue linear heat cable, Rilsan + stainless steel - 500 m Page : 40 Digital heat sensing cable 68°C - 500 m Page : 41 'A' clip for heat cable 100/pack Page : 42 'P' clip for heat cable 100/pack Page : 42 'T' clip for heat cable 100/pack Page : 43 Edge clip for heat cable 2-3 mm 100/pack Page : 43 CO detection control panel - 1 Zone (English Version) Page : 44 CO detection control panel - 3 Zones (English Version) Page : 45 CO detection expansion module (English Version) Page : 46 Blanking plate for KM260 panels Page : 47 CO detector with base and mounting supplement Page : 48 Manual call point, flying leads, red Page : 49 Surface mount manual call point IP67, red Page : 50 Intrinsic safe manual call point, including back box Page : 51 Manual call point with keyswitch, flying leads, red Page : 52 Break glass, EN54, Aritech logo Page : 53 EN54 universal glass for manual call point Page : 53 Hinged transparent MCP protection cover Page : 54 Surface mounting box with connectors, red Page : 54 Surface mount box without connectors, red Page : 55 Resetable Manual Call Point Page : 56 Flush mount cradle Page : 57 Hinged transparent MCP protection cover for PK20 Page : 57 Mini disc remote indicator Page : 58 Optical Remote Indicator Page : 59 Optical and Accustical Remote Indicator Page : 60 Illuminated warning sign (No text) 24VDC Page : 61 Low current remote LED indicator Page : 62 Compact panel mount sounder Page : 63 Sounder, 32 tones - shallow base - RED Page : 64 Sounder, 26 tones - deep base - RED Page : 65 Combined sounder and beacon, 2 tones, red lens - shallow base Page : 66 Sounder, 4 tones, low profile - low current RED Page : 67 Sounder, 3 tones - low current, high output RED Page : 68 Electronic solenoid bell, 24 VDC, red Page : 69 Low consumption multi-tone alarm siren Page : 70 Alarm sounder with beacon Page : 71 Alarm sounder with indicator (Spanish Version) Page : 72 PA40 CK406 FE831 FE832 FE835 FE835VDS FE836 FE841 FE841VDS FE845 FE845-40 FE845-150 FE845-250 FE848 FE851VDS FE852VDS FE855VDS FE858 FG010 TR010 TH010 TH012 ET010 SC008 CB001 KP300S EP300 SPN500 PM705 PM831 PM832 PM833 PM835 BS122N BS127N KAL21 KAL21A KAL21B KAL51 KAL51A KAL51B Xenon strobe light Page : 72 Fire alarm bell Page : 73 Door holder, steel box, surface mount, basic Page : 74 Door holder, steel box, surface mount complete Page : 75 Door holder, steel square base Page : 76 Door holder, steel square base, VDS magnet Page : 77 Door holder, flush mounting Page : 78 Door holder, reinforced aluminium box Page : 79 Door holder, reinforced plastic box, VDS magnet Page : 80 Door holder, wall mount, reinforced aluminium box Page : 81 Reinforced aluminium extension for FE845, 40mm Page : 82 Reinforced aluminium extension for FE845, 150mm Page : 82 Reinforced aluminium extension for FE845, 250mm Page : 83 Door holder, floor mounting, reinforced aluminium box Page : 84 Door holder, universal adjustable tube, 175mm, VDS magnet Page : 85 Door holder, universal adjustable tube, 475mm, VDS magnet Page : 86 Door holder, steel square base, IP65, VDS magnet Page : 87 Door holder, explosion proof Page : 88 Universal detector removal tool on a swing frame Page : 89 Touch sensitive transparent dispenser cup on swing frame Page : 90 Mains operated heat detector test tool on swing frame Page : 91 Cordless, battery operated, heat detector on swing frame Page : 92 Fibreglass telescopic pole 1.26 m - 4.5 m Page : 93 Aerosol test Spray for Smoke Detectors Page : 94 Canvas carrying bag for the test and service equipment Page : 95 Smoke detector test kit Page : 95 Extension element for detector test pole (1m) Page : 96 Test gas for EP300 test equipment Page : 96 EN 54-4 approved, 24 V 5A Intelligent Power Supply Page : 97 Boxed power supply, 24VDC 1A Page : 98 Boxed power supply, 24VDC 2A Page : 99 Boxed power supply, 24VDC 3A Page : 100 Boxed power supply, 24VDC 5A Page : 101 Sealed Lead-Acid Battery - 12V 2.2Ah Page : 102 Sealed Lead-Acid Battery - 12V 7.2Ah Page : 103 Fire Alarm Cable 2 x 1.5 mm² (RED) Page : 104 Fire Alarm Cable 2 x 1.5 mm² (RED) Page : 104 Fire Alarm Cable 2 x 2 x 1.5 mm² (RED) Page : 105 Fire Alarm Cable (Halogen Free) 2 x 1.5 mm² (RED) Page : 105 Fire Alarm Cable (Halogen free) 2 x 1.5 mm² (RED) Page : 106 Fire Alarm Cable (Halogen Free) 2 x 2 x 1.5 mm² (RED) Page : 107 www.gesecurity.net IPSCAT-2005-12-6 16:20:13 As a company of innovation, GE Security reserves the right to change product specifications without notice. For the latest product specifications, visit GE Security online or contact your GE Security sales representative.