Transcript
CL2L Telephone ringer amplifier with flasher and
door bell Indicateur d’appel téléphonique avec flash et sonnette Telefonklingelverstärker mit Blitz und Türklingel
English Page 2 Français Page 15 Deutsch Page 28
CAUTION: The switch for Ringer ALARM selection must never be set during ringing/ flashing mode but always when CL2 is silent mode ( No incoming call ringing). ATTENTION: Le commutateur de configuration du mode Alarme ne doit jamais être changé lorsque le CL2 envoie sa sonnerie ( ou flash lumineux ) mais uniquement durant le mode repos. WARNUNG: Bitte die Taste für die Auswahl des Klingeltons niemals während des Läutens bzw. Blitz-Signals betätigen, sondern nur im Ruhe-Modus ( kein eingehender Anruf ).
1
DESCRIPTION 1. DESCRIPTION The CL2 will alert you to both doorbell and telephone. It has adjustable volume and different tone settings for doorbell and telephone. FRONT VIEW Volume 4 ringer Door bell Phone ringer control LED Doorbell Tone settings amplifier tone control control
Strobe flasher BELL PUSH
Loud sound alarm
Paring/Test
REAR VIEW
Wall mounting holes
Bell push button Telephone line Shaker socket (*) cord socket (*) Mains power lead socket (*) Modular jack for telephone line cord (*) (*) Classified TNV-3 according to EN60950 standard.
2
INSTALLATION 2. INSTALLATION 230V Double plug
Screw wall mount
AC/DC d t
Door Bell Button Door Bell
Wall socket Telephone Option : Special cable to link two CL2s
Option : Shaker (ref.: SHAKCL_BLK only)
1 - Connect the CL2 line cord in CL2 “Line IN”. 2 - Connect your Telephone in the double plug of the line cord. 3 - Connect the double plug in the Telephone wall socket. 4 - If necessary connect the required shaker (SHAKCL_BLK only) to the shaker plug input. 5 - Connect the mains adaptor line cord in CL2 12V DC input. 6 - Connect the mains adaptor in the 230V wall socket. (*)
3
INSTALLATION (*) Classified "hazardous voltage" according to EN60950 standard.
Electrical connection: The apparatus is designed to operate from a 230V 50Hz supply only. (Classified as 'hazardous voltage" according to EN60950 standard). The apparatus does not incorporate an integral power on/off switch. To disconnect the power, either switch off supply at the mains power socket or unplug the AC adaptor. When installing the apparatus, ensure that the mains power socket is readily accessible. Telephone connection: Voltages present on the telecommunication network are classified TNV-3 (Telecommunication Network Voltage) according to the EN60950 standard.
4
BELL PUSH
WALL MOUNTING
3.1. BELL PUSH – WALL MOUNTING The wire free bell push is mounted by the front door. It has a range of 20-60 metres depending on the structure of the building (see note). Test the system before mounting on the wall – plug in the CL2 and press the bell push button to check that the CL2 rings. To mount the bell push, open the access cover in the middle of the bell push with a needle or small screwdriver. Decide where to position the bell push and use the wall mount template, shown below, to mark the holes on the wall or door surround and drill holes if necessary. Align with prepared marks or screwholes, insert and tighten screws and replace access cover. Bell push is now ready for use. Note: Do not place the bell push onto a metallic base or near electric equipment (such as TV, Radio, computer, washing machine...). The CL2 will work within a range of 60m in an environment where there are no obstacles and 20m in an environment which contains a wall or metallic structure.
5
BELL PUSH
WALL MOUNTING WALL MOUNTING TEMPLATES
To wall mount the bell push or the CL2, use these templates to mark the screw hole centres. We recommend the use of a spirit level to ensure the holes are level.
CL2 template
Bell push template
6
BELL PUSH
CHANGE THE BATTERY
3.2. CHANGE THE BATTERY The door bell is supplied with a 23A 12V battery. The CL2 is supplied ready to use, it is not necessary to open the bell push when you first install the CL2. To replace the battery, open the access cover and unscrew the door bell from the wall, unscrew the three screws located on the base and open the box to get access to the battery compartment. Replace the battery, replace back and remount.
Back of Bell Push
Inside Bell Push Battery
Unscrew to open
Switches for LED colour
Note: Do not use a rechargeable battery. Do not put the used battery into the household rubbish, pay attention to battery regulations regarding battery disposal.
7
SETTINGS
CL2
4.1. CL2 SETTINGS ALARM MODE SETTING For incoming calls – choose which alarm mode you want by moving the alarm mode switch to one of the following positions: No alarm selected Doorbell/ringer amplifier and strobe flasher Doorbell, strobe flasher and shaker (if connected)
Flasher: Bell push – 3-4 flashes Telephone – flashes as long as phone rings
Doorbell/ringer amplifier and shaker (if connected) VOLUME CONTROL For doorbell and ringer amplifier: Use the slider control to adjust the volume of the sound alarm of the CL2.
8
SETTINGS
CL2
RING TONE CONTROL The three position switch allows you to set the tone of the CL2 ringer when the telephone rings. DOOR BELL TONE CONTROL This three position switch allows you to set a different tone when the door bell rings. OPTIONAL ACCESSORIES: Extra bell push – to cover a second door, such as a kitchen door. Shaker – the Geemarc shaker unit (CLA2) can be tucked under your pillow or at the side of your chair to vibrate when the doorbell or telephone rings. Particularly useful for hearing aid wearers, when they are not wearing their hearing aids at night. Wrist watch alarm – can be worn by someone in the house who is bedbound and may need to call for help. To purchase these items, contact your dealer. In case of difficulty, visit the Geemarc website on: www.geemarc.com
9
SETTINGS
PAIRING
4.2. The Pairing Procedure ( Note : Factory default setting : paired. ) 1. Press and hold the (Pairing/Test) button for 2 seconds to enter pairing mode, at the same time, the unit makes a beep sound. 2. The 1st LED lights, to pair the BELL PUSH, press and (Pairing/Test) button and then Bell hold the push button at the same time, the 1st LED flashes, after paired, the 1st LED lights and stop flashing, beeps to confirm. 3. If user wants to pair the 2nd or 3rd BELL PUSH, when (Pairing/Test) the 1st LED lights, press the button within 2 seconds, the 1st LED goes off and then the 2nd LED lights. User is able to pair the 2nd BELL PUSH, repeat the same procedure for the 3rd. 4. Repeat the above, all 3 LEDS flashing together for the 4th BELL PUSH pairing, the BELL TONE is not adjustable for the 4th BELL PUSH. 5. If paired more BELL PUSH on same LED, only the last one kept.
10
SETTINGS
PAIRING
4.3. Un- Register The Pairing 1. Press and hold the Pairing/Test button for 5 seconds to enter un-register mode, 3 LED light together. 2. If user wants to un-register the 1st BELL PUSH, press the Pairing/Test button within 2 seconds, the 1st LED will be flashing (the other 2 LED light), means user is now un-registering the 1st BELL PUSH, press the Pairing/Test button until the 1st LED goes off, beeps to confirm. The 1st remote is now un-registered. 3. If user wants to keep the 1st BELL PUSH but unregister the 2nd or 3rd BELL PUSH, when the 1st LED flashes, press the Pairing/Test button within 2 seconds, the 2nd LED flashes (other 2 LED light), to select which BELL PUSH to be un-registered. Note : 1. To check whether the unit works normally, you can (pairing/Test) button, the unit would press the sound alarm and flash. 2. Don’t unregister a BELLPUSH unless it is really necessary.
11
TROUBLESHOOTING 5. TROUBLESHOOTING If the CL2 system doesn't work correctly, please carry out the following checks before calling the helpline: ● If the phone rings but the CL2 does not ring: Check the connection between the phone socket and the CL2. ● If the door bell does not ring: 1. Check that the CL2 is plugged into the mains and switched on. 2. Unscrew the bell push and check the battery is correctly fitted. 3. Try fitting a new battery. 4. Check that the Bell push paired with CL2, please refer to page 10/Setting for how to pair the Bellpush with CL2.
12
GUARANTEE 6. GUARANTEE From the moment your Geemarc product is purchased, Geemarc guarantee it for the period of one year. During this time, all repairs or replacements (at our discretion) are free of charge. Should you experience a problem then contact our helpline or visit our website at www.geemarc.com. The guarantee does not cover accidents, negligence or breakages to any parts. The product must not be tampered with or taken apart by anyone who is not an authorised Geemarc representative. The Geemarc guarantee in no way limits your legal rights.
IMPORTANT: YOUR RECEIPT IS PART OF YOUR GUARANTEE AND MUST BE RETAINED AND PRODUCED IN THE EVENT OF AWARRANTY CLAIM.
The guarantee applies to the United Kingdom only. Declaration: Geemarc Telecom SA hereby declares that this product is in compliance with the essential requirements and other relevant provisions of the Radio and Telecommunications Terminal Equipment Directive 1999/5/ EEC and in particular article 3 section 1a, 1b and section 2. The declaration of conformity may be consulted at www.geemarc.com
13
RECYCLING DIRECTIVES 7. RECYCLING DIRECTIVES Recycling directives: The WEEE (Waste Electrical and Electronic Equipment) Directive has been put in place so that products at the end of life are recycled in the best way. When this product is out of order, please do not put it in your domestic waste bin. Please use one of the following disposal options: – Remove the batteries and deposit them in an appropriate WEEE skip. Deposit the product in an appropriate WEEE skip. – Or hand the old product to the retailer. If you purchase a new one, they should accept it. Thus if you respect these instructions you ensure human health andenvironmental protection.
For product support and help visit our website at www.geemarc.com Telephone: +44 (0)1707 384438 or Fax +44 (0)1707 832529
14