GELOGiV12900L SOLAR (12V 90Ah GEL Battery) Floating Life at 20°C designed for 10-12 years Dimensions Temperature Effects in Relation to Battery Capacity 110 Available capacity/ % 100 90 80 70 60 C20 C10 50 C5 C3 40 C1 30 -20 -15 -10 -5 0 5 10 15 20 25 30 B at t ery t em p erat u re °C Specifications Float Charging Characteristics Nominal Voltage 12V C100: 90Ah (1,80V/cell) CHARGE VOLUME % C20: 77.6Ah (1,70V/cell) Capacity (25°C) Length Dimensions 0.1C 2.4 0.08C 2.3 0.06C 2.2 100 (1,70V/cell) 80 350mm (13.8inch) Width 0 Tem perat ure(25 C £ £0. 1CA -2. 25V / c ell£ 120 C10: 71.4Ah (1,70V/cell) C5: 62Ah CHARGING CHARGING CURRENT VOLTAGE (A) ( V/ce ll) 60 174mm (6.85inch) C H A R G ED VO L U M E C H A R G E VO LTA G E (C ons ta nt 2 .2 5 v /c e ll) A FTER 5 0 % D I SC H A R G E Height 190mm (7.48inch) 40 0.04C 2.1 Total Height 190mm (7.48inch) 20 0.02C 2.0 Approx. Weight 24.3kg (53.6lbs) 0 0C Maximum charging current 22.5A Maximum discharge current 700A (5sec.) Internal resistance Approx. 6.4mΩ A FTER 1 0 0 % D ISC H A R G E C =C2 0 CHARGING CURRENT Self-discharge (25°C) 40°C 103% 25°C 100% 4 8 12 16 20 24 28 32 Charging Tim e (hours) Cycle Life in Relation to Depth of Discharge Acc.to IEC 8 9 6 -2 (2 5 0 C / 7 70 F) 100 0°C 86% -15°C 65% 3 month Remaining Capacity: 91% 6 month Remaining Capacity: 82% 12 month Remaining Capacity: 65% Nominal operating temperature 90 25°C ±3°C (77°F±5°F) Float charging voltage (25°C) -20°C ~ 55°C (-4°F ~ 131°F) 13.65 to 13.80V Cyclic charging voltage (25°C) 14.40 to 15.00V Operating temperature range Ext ract ed cap acit y in % Capacity affected by temperature (20hr) 0 Terminal material 80 70 60 50 40 30 20 10 400 800 1200 1600 2000 2400 2800 3200 3600 4000 Number of Cycles Copper Constant Current Discharge Characteristics (Ampere / Cell, 25°C) F.V/TIME 1.60V/cell 1.70V/cell 1.80V/cell 20min 99,2 88,0 72,6 30min 72,9 65,6 55,6 45min 53,5 48,1 41,9 1h 43,8 39,8 35,1 2h 26,1 24,5 21,9 3h 19,5 18,1 16,5 4h 15,5 14,6 13,5 5h 13,1 12,4 11,6 6h 11,1 10,7 10,0 7h 9,75 9,41 8,80 8h 8,72 8,44 7,94 9h 7,97 7,70 7,29 10h 7,36 7,14 6,84 20h 3,96 3,88 3,75 50h 1,74 1,71 1,65 100h 0,950 0,931 0,900 5h 25,3 24,2 22,7 6h 21,6 21,0 19,7 7h 19,1 18,5 17,4 8h 17,1 16,7 15,8 9h 15,8 15,3 14,5 10h 14,6 14,1 13,6 20h 7,88 7,70 7,48 50h 3,47 3,39 3,29 100h 1,891 1,848 1,795 Constant Power Discharge Characteristics (Watt / Cell, 25°C) F.V/TIME 1.60V/cell 1.70V/cell 1.80V/cell 20min 179,3 162,5 137,3 30min 134,0 122,9 106,3 45min 100,1 91,3 80,7 1h 83,0 76,2 68,0 2h 50,0 47,4 42,4 3h 37,4 35,3 32,1 4h 30,1 28,5 26,5 Valid from 03-2013