Preview only show first 10 pages with watermark. For full document please download

Gem-p816 V30 Program Manual Alpha Keypads

   EMBED


Share

Transcript

PROGRAMMING INSTRUCTIONS R Publicly traded on NASDAQ Symbol: NSSC HARDWIRE WIRELESS GEM-P816 CONTROL PANEL/COMMUNICATOR Programming the GEM-P816 Control Panel with the "Classic" GEM-RP1CAe2 Keypad and the "K Series" GEM-K1CA Keypad GEMINI GEMINI SYSTEM READY 11/01/09 12:00 AM SYSTEM READY 11/01/09 12:00 AM ED ARM T ST A US A 1 2 3 NEXT/YES D F G B 4 5 6 C 7 8 9 0 E PRIOR/NO AREA C O M P UT E R I ZE D S E C U R I T Y SY S T E M "Classic" GEM-RP1CAe2 ARM ED T ST A US U R 1 2 3 B 4 5 6 C 7 8 9 0 NEXT/YES P PRIOR/NO Q AREA G C O M P UT E R I ZE D S E C U R I T Y S Y S T E M "K Series" GEM-K1CA Quick Start (for "Classic" GEM-RP1CAe2) Quick Start (for "K-Series" GEM-K1CA) 1. Refer to the wiring diagram, connect Siren, Aux. Power, PGM Output, Remote Bus, Earth ground, Zone and Telephone wiring. NOTE: See Installation Instructions (WI994). 1. Refer to the wiring diagram, connect Siren, Aux. Power, PGM Output, Remote Bus, Earth ground, Zone and Telephone wiring. NOTE: See Installation Instructions (WI994). 2. Connect AC power first and then the battery. 2. Connect AC power first and then the battery. 3. Configure the keypad (see page 42). 3. Configure the keypad (see page 42). 4. Access the Easy Menu Driven (Dealer Program) Mode: 4. Access the Easy Menu Driven (Dealer Program) Mode: Press 456789 A Press 456789 R Dealer Code Dealer Code Press NO (g) until “ACTIVATE PROGRAM Y/N” appears on the keypad display. Press NO (Q) until “ACTIVATE PROGRAM Y/N” appears on the keypad display. Press YES (F) to Enter Dealer Program Mode. Go to page 5. Press YES (P) to Enter Dealer Program Mode. Go to page 5. © NAPCO 2008 WI995E 5/08 THIS MANUAL INCLUDES FEATURES WHICH ARE ONLY AVAILABLE IN CONTROL PANEL FIRMWARE VERSION 30G OR LATER. CHANGES FROM PREVIOUS EDITION The following changes have been made to this manual (WI995E) since the previous edition (WI995D): • • ‡ All "Not for UL installations" footnote references have been made changed to a consistent "double dagger" symbol (" "). Warning added to page 2 (see below). Warning: The use of non-NAPCO wireless devices with this control panel has not been evaluated by UL and voids the UL listing. In addition, the performance of these devices can not be guaranteed as compatible with NAPCO control panels. IMPORTANT NOTE This manual supports the keypad programming of the GEM-P816 control panel with the NAPCO "classic" GEMRP1CAe2 keypad as well as the GEM-K1CA "K Series" keypad. The new "K Series" GEM-K1CA model offers the new STAY and AWAY buttons with simplified functionality, along with the new MENU and ENTER buttons. While the instructions in this manual are depicted using the GEM-K1CA keypad, the manual applies to both the "classic" and the "K Series" keypads. Program Mode is the same for both keypads--only the button names have changed, as follows: • The A button and the R button operate identically (in Program Mode) for both keypads. • The D button and the U button operate identically (in Program Mode) for both keypads. button and the button operate identically (in Program Mode) for both keypads. The words • The "NEXT/YES button" are used in this manual. button and the button operate identically (in Program Mode) for both keypads. The words • The "PRIOR/NO button" are used in this manual.  For consistency, it is recommended that all keypads either be all "classic" or all "K Series"--both keypad types should not be used in one alarm system. NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com Page 3 TABLE OF CONTENTS SYSTEM PROGRAMMING OPTIONS .....................................4 INTRODUCTION .................................................................4 DOWNLOADING FROM A COMPUTER .............................4 EASY MENU DRIVEN PROGRAM MODE ...............................5 Dealer Program - Preliminary Information ...........................5 Accessing Dealer Program Mode ........................................5 Customizing a Default Program ...........................................5 GEM-RP1CAe2/GEM-K1CA Easy Program Menu .........6 Total Number of Zones in Area 1 ................................6 Fire Zones in Area 1 ...................................................6 2-Wire Fire Zones in Area 1 ........................................6 Local or Central Station Reporting System .................6 Exit/Entry Zones in Area 1 ..........................................6 Interior Zones in Area 1 ..............................................6 24 Hour Zones in Area 1 .............................................6 Chime Zones in Area 1 ...............................................7 Chime 2 Zones in Area 1 ............................................7 Exit/Entry2 Zones in Area 1 ........................................7 50 mS Loop Response Zones .....................................7 Aux Output Activated on Alarm Zones ........................7 Sensor Watch Zones .................................................7 Keypad Sounder On Alarm Zones ..............................7 Auto Bypass Re-entry Zones ......................................7 Enable No EOLR Zones .............................................7 Enable Telco Line Fault Test? ....................................7 Enable Burg Output Chirp on Keyfob? ........................8 Enable SIA CP-01 Features? ......................................8 Number of Keypads in Area 1 ....................................8 Central Station Receiver 1 Telephone Number ...........8 Central Station Receiver 1 Account Number ...............8 Central Station Receiver 1 Format ..............................8 Enter User Codes ......................................................8 RF Transmitter Points .................................................9 Keyfob Transmitters as Arm/Disarm & Control Devices ................................................................9 Keyfob Transmitters as Zone Input Devices .............10 Enter Zone Descriptions ...........................................10 Enter Date ................................................................10 Enter Time ................................................................10 Dealer Code..............................................................10 Test Timer ................................................................10 Clear Dealer Program ...............................................10 Cold Start..................................................................10 DIRECT ADDRESS PROGRAM MODE .................................11 Direct Address Overview ...................................................11 Address Mode Displays .....................................................11 Binary (Bit) Format Example ...................................11 Decimal Format Example ........................................12 Hexadecimal Format Example.................................13 Programming Conventions Used in this Manual ................14 SYSTEM DELAYS & TIMEOUTS .....................................15 SYSTEM OUTPUT TIMEOUTS ........................................16 DOWNLOAD/CALLBACK OPTIONS ................................16 PAGER FORMAT OPTIONS .............................................16 SYSTEM OPTIONS.....................................................17, 19 CS RECEIVER OPTIONS ................................................20 CS SUBSCRIBER ID OPTIONS .......................................21 CS SYSTEM REPORTING OPTIONS ..............................22 CS AREA & SYSTEM REPORTING OPTIONS ................22 CS ZONE REPORTING OPTIONS....................................23 CS USER REPORTING OPTIONS....................................24 EZM GROUP OPTIONS ...................................................25 AREA BELL CONTROL OPTIONS ...................................26 KEYPAD OPTIONS ..........................................................27 TEMPERATURE DISPLAY AT KEYPAD ..........................28 ZONE OPTIONS - ZONES 1 TO 16 .................................29 RF RECEIVER & SUPERVISORY TIMER OPTIONS .......36 CLEAR PROGRAM OPTIONS .........................................37 USER PROGRAM MODE .......................................................37 Preliminary Information ......................................................37 Accessing User Program Mode..........................................38 User Codes ........................................................................38 Zone Descriptions ..............................................................39 Date ...................................................................................39 Time...................................................................................39 KEYPAD CONFIGURATION MODE .......................................40 Keypad Installation.............................................................40 Configuring the Keypads ....................................................40 EASY MENU PROGRAMMING WORKSHEETS ....................42 ALPHABETICAL INDEX..........................................................46 ADDRESS NUMBER INDEX...................................................51 GEM-P816 WIRING DIAGRAM...............................................56 Refer to accompanying GEM-P816 Installation Instructions (WI994) for installation information. NAPCO Security Systems R GEM-P816 Programming Instructions Page 4 SYSTEM PROGRAMMING OPTIONS INTRODUCTION The GEM-P816 control panel may be programmed by various means, each of which will be covered in detail in the sections that follow. Keypad displays shown are for a GEM-RP1CAe2/K1CA (version 8 keypad), the recommended keypad for programming. For Programming Instructions with the GEM-RP2ASe2/GEM-K2AS, GEM-RP3DGTL/GEM-K3DGTL and the GEM-RP4RFC/GEM-K4RF series, see WI1182. Downloading From a Computer. This is the preferred method of programming. The panel may be downloaded from (or uploaded to) an IBM PC-compatible computer, either locally or remotely. Napco's PCDWindows Quickloader software features context-sensitive help screens as well as an error-checking utility that prevents programming of incompatible or conflicting data to ensure proper panel operation. Note: Unattended downloading from a computer is not allowed for Fire Alarm or UL installations. Easy Menu-Driven Program (Dealer Program) Mode - Keypad Programming. The Easy Menu-Driven Program Mode allows keypad programming of number of zones in area 1, number of fire zones (both 4-wire and 2wire), local or Central Station reporting, number of exit/entry zones, number of interior zones, number of 24 hour zones, number of chime zones, Chime 2 zones, Exit/Entry2 zones, 50ms loop response zones (Note: 750mS is required for Loop Response time in UL installations), aux output activated on alarm zones, sensor watch zones, keypad sounder on alarm zones, auto bypass re-entry zones, EOLR zones, number of keypads in area 1, Central Station telephone number, Central Station account number, Central Station receiver format, User Codes, RF transmitter points, RF keyfob transmitters, zone descriptions, date/time, dealer code, Test Timer, Telco line fault test, Burg output chirp on keyfob, keypad time/date display, enable CP-01 programming, and clear dealer program/cold start. For new panels, a custom default program may be created at the keypad. A menu-driven utility prompts the installer to configure the system. Further detailed customization is accomplished in the Direct Address Program Mode. Direct Address (Dealer Program) Program Mode - Keypad Programming. The Direct Address Program Mode is an extension of the Dealer Program Mode wherein data is entered at the keypad by location. This mode is accessed from the Easy Menu Driven Program Mode by pressing the C button at any time. User Program Mode - Keypad Programming. The User Program Mode is intended for authorized users and is limited to keypad programming of User Codes, Time, Date and Zone Descriptions. DOWNLOADING FROM A COMPUTER The control-panel program may be downloaded from the computer by any of the following methods. Local Downloading (Note: This procedure should be used after installation, after peripheral devices are connected). For direct high-speed data transfer to the control panel from a desktop computer, connect the download jack (JP2) on the panel to the LOCAL jack (J3) on the Napco PCI2000/3000 computer interface using the supplied 6conductor cable. (Refer to PCI2000/3000 Installation Instructions WI443 for wiring diagram and procedures). Similarly, a high-speed local download may be made in the field using a notebook or laptop computer. Connect JP2 on the control panel to a Napco PCI-MINI computer interface using the 6-conductor cable supplied. (Refer to PCI-MINI Installation Instructions WI767). Remote Downloading (Also see PCI2000/3000 Installation Instructions WI443). Note: Unattended downloading from a computer is not allowed for Fire Alarm or UL installations. Function Mode Start by establishing a telco connection between the computer operator and the installer. During this procedure, voice contact will be lost, therefore both the installer and the computer operator should be familiar with the operation. When a steady high-pitched tone is heard at the site phone, access the “ACTIVATE DOWNLOAD” Function (see Keypad Programming Modes), then press the U button or the NEXT/YES button; the site phone will go dead. Hang up the phone and wait for a call from the central station confirming a successful download. Callback Method An installed, unattended panel may be programmed or reprogrammed remotely using the Callback-Method Download feature of the PCD-Windows software. Remote downloading requires a modem compatible with the PCI2000/3000. Upon answering the call from the computer, the panel will verify the Download Security Code and, if confirmed, will establish a connection. If a Callback Number is programmed into the panel, the panel will automatically disconnect and call the computer at this number before establishing a connection. NAPCO Security Systems GEM-P816 Programming Instructions R Page 5 EASY MENU DRIVEN PROGRAM MODE DEALER PROGRAM - PRELIMINARY INFORMATION  The Default Dealer Code is 4 5 6 7 8 9. Use this code to enter the Dealer Program Mode to program a custom Dealer Code, which replaces the Default Dealer Code. If you clear your Dealer Code, use the Default Dealer Code once again to enter programming.  After entering codes or data, press the save U button. Data will not be stored into memory unless U is pressed.  If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.  Silence the sounder by the G button to continue, or by pressing the C button to exit.  When programming a Multiple Area System, Direct Address Programming Mode must be used to complete the program. For ease of programming, it is recommended that a GEM-RP1CAe2 or GEM-K1CA be used. If a GEM-RP2ASe2/ GEM-K2AS is used, see WI1182. ACCESSING DEALER PROGRAM MODE 1. Press 456789 R Dealer Code (Default = 2. Press PRIOR/NO button until “ACTIVATE PROGRAM Y/N” appears on LCD screen. 3. Press NEXT/YES button to Enter Dealer Program Mode. 4. Press CC to Exit Dealer Program Mode when finished. CUSTOMIZING A DEFAULT PROGRAM For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for: • • • • • • • • • • • Number of Zones in Area 1 Fire Zones in Area 1 2-Wire Fire Zones in Area 1 Local or Central Station Reporting System Exit/Entry Zones in Area 1 Interior Zones in Area 1 24 Hour Zones in Area 1 Chime Zones in Area 1 Chime 2 Zones in Area 1 Exit/Entry2 Zones in Area 1 50mS Loop Response Zones (Note: 750mS is re- quired for Loop Response time in UL installations). • • • • • • • • • • • Aux Output Activated on Alarm Zones Sensor Watch Zones Keypad Sounder on Alarm Zones Auto Bypass re-entry Zones Enable no EOLR Zones Enable Telco Line Fault Test Enable Burg Output Chirp on Keyfob Enable CP-01 Programming Number of Keypads in Area 1 Central Station Receiver 1 Tel. Number Central Station Receiver 1 Account Number • Central Station Receiver 1 Format • Enter User Codes • RF Transmitter Points • Quick "Enroll" Method • Keyfob Transmitters • Enter Zone Descriptions • Enter Date • Enter Time • Dealer Code • Test Timer This procedure will automatically set up system keypads, EZMs, wireless transmitters, etc. After your basic default program has been loaded, you may alter it as necessary in the Direct Address Program Mode. NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any means, the number zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press the C button to enter the Direct Address Program Mode; (b) access Location 2285 (Clear Program); (c) press the U button and start over. NAPCO Security Systems R GEM-P816 Programming Instructions Page 6 GEM-RP1CAe2/GEM-K1CA Keypad Easy Program Menu To create a custom program using the GEM-RP1CAe2/GEM-K1CA keypad, simply answer the following questions and record your information on the Easy Menu Programming Worksheet. In each of the following steps, press R to set cursor, the NEXT/ YES button to go forwards, the PRIOR/NO button to go backwards, U to save and C twice to exit at any time. #of Zns in Area1 Enter # Zones XX (Direct Entry) Fire Zones Enter Zone # °° (Direct Entry) Total Number of Zones in Area 1 (New Program Only) • Enter the total number of zones to be programmed for Area 1. • Valid entries are from 01 to 16. Directly enter the total number of zones, including leading zeros. • The system is based on groups of 4 zones each (after the first 8 zones), and will automatically round up to the next group of 4. For example, if you enter 18, it will automatically convert this to 20 zones. Press U to save. Press the NEXT/YES button to proceed. Fire Zones in Area 1 (New Program Only) • Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless). • Valid entries are from 01 to 16. • Directly enter each zone number, including leading zeros, and press U to save, and then repeat for any additional zone(s). Press the NEXT/YES button to proceed. 2-Wire Fire Zns Enter Zone # ° ° (Direct Entry) 2-Wire Fire Zones in Area 1 (New Program Only) • Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire smoke detectors. • Valid entries are 07 and 08. Directly enter each zone number, including leading zeros. • Press U to save, and repeat for any additional zone(s); press NEXT/YES to proceed. NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones. JP3 must be set to “2-WF” position for 2-wire fire. (refer to Installation Instructions). Report All Zones To Central? Y/N Local or Central Station Reporting System (New Program Only) Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system (Press YES or NO) Exit/Entry Zones in Area 1 (New Program Only) Exit/Entry Zones Enter Zone # XX (Direct Entry) • Enter the zone numbers of zones to be used as Exit/Entry zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed. NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed. Interior Zones in Area 1 (New Program Only) Interior Zones Enter Zone # XX (Direct Entry) • Enter the zone numbers to be used as Interior Zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save and then repeat for any additional zone(s). • Press the NEXT/YES button to proceed. • All Interior zones will also be automatically programmed as “Exit/Entry Follower” and as "Power Up Delay" zones. 24 Hour Zones Enter Zone # °° (Direct Entry) 24 Hour Zones in Area 1 (New Program Only) • Enter the zone numbers of zones to be used as 24 Hour zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed. NOTE: 24 Hour Zones will automatically be programmed as audible (Burg Output). NAPCO Security Systems GEM-P816 Programming Instructions R Page 7 Chime Zones Enter Zone # °° (Direct Entry) Chime Zones in Area 1 (New Program Only) • Enter the zone numbers which are to be used as Chime Zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), press the NEXT/YES button to proceed. NOTE: A chime time of 2 seconds will be automatically programmed. Chime 2 Zones Enter Zone # °° (Direct Entry) Chime 2 Zones in Area 1 (New Program Only) • Enter the zone numbers which are to be used as Chime 2 Zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), Press the NEXT/YES button to proceed. NOTE: A chime time of 2 seconds will be automatically programmed. Chime 2 zones give a distinct pulsating tone when zone is faulted. Exit/Entry2 Zones Enter Zone # °° (Direct Entry) Exit/Entry2 Zones in Area 1 (New Program Only) • Enter the zone numbers of zones to be used as Exit/Entry zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save and repeat for any additional zone(s); press the NEXT/YES button to proceed. NOTE: An Exit/Entry 2 Entry Time of 30 seconds will automatically be programmed. 50mS Loop Zones Enter Zone # °° (Direct Entry) 50 mS Loop Response Zones (New Program Only) Note: 750mS is required for Loop Response time in UL installations. • Enter the zone numbers of zones to be have a 50mS loop response. • Valid entries are from 01 to 08. Directly enter each zone number, including leading zeros. • Press U to save and then repeat for any additional zone(s), Press the NEXT/YES button to proceed. Note: Only panel zones 01-08 can be programmed for Quick Loop Response. All other zones can be programmed via their respective EZM's (hardwire). Time can also be adjusted via address 2280. Aux Output Zones Enter Zone # ° ° (Direct Entry) Aux Output Activated on Alarm Zones (New Program Only) • Enter the zone numbers of zones to activate the PGM2 upon alarm. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), Press the NEXT/YES button to proceed. NOTE: A PGM2 Timeout of 15 minutes will automatically be programmed. Sensor Watch Zns Enter Zone # ° ° (Direct Entry) Sensor Watch Zones (New Program Only) • Enter the zone numbers of zones to be Sensor Watch zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), Press the NEXT/YES button to proceed. NOTE: A Sensor Watch Time of 24 hours will automatically be programmed. KP Sndr Alrm Zns Enter Zone # ° ° (Direct Entry) Auto Byp REnt Zn Enter Zone # ° ° (Direct Entry) Keypad Sounder On Alarm Zones (New Program Only) • Enter the zone numbers of all zones to activate the Keypad Sounder upon alarm. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), Press the NEXT/YES button to proceed. Auto Bypass Re-entry Zones (New Program Only) (Not Evaluated by UL) • Enter the zone numbers of zones to be Auto Bypass Re-entry zones. • Valid entries are from 01 to 16. Directly enter each zone number, including leading zeros. • Press U to save, then repeat for any additional zone(s), Press the NEXT/YES button to proceed. • Auto Bypass Re-entry Zones allow the system to be armed with the zone faulted but come back into the system (armed) when the zone is subsequently closed. Enable No EOLR Zones Y/N Enable No EOLR Zones (New Program Only) • Press YES to program all zones except 24 Hr & fire zones for No End Of Line Resistor. Press NO to continue. Do NOT program this feature for UL installations. (Press YES or NO) Enable Telco Line Test? (Press YES or NO) Y/N Enable Telco Line Fault Test? • Press YES to enable Telco Line Fault Test. • Press NO to continue. NOTE: If enabled, a Telco Line Fault Test Delay of 60 sec. will automatically be programmed. NAPCO Security Systems R GEM-P816 Programming Instructions Page 8 Enable Burg Out Chirp? Y/N (Press YES or NO) Enable SIA CP-01? Y/N (Press YES or NO) # Area 1 Keypads Enter # KPs 01 (Direct Entry) Enable Burg Output Chirp on Keyfob? • Press the NEXT/YES button to enable Burg Output Chirp on Keyfob Arm / Disarm. • Press the PRIOR/NO button to continue. NOTE: The Burg Output will chirp once on Keyfob Arm and twice on Keyfob Disarm. Enable SIA CP-01 Features? • Press the NEXT/YES button to enable. • Press the PRIOR/NO button to continue. The SIA CP-01 Features are designed to reduce the incidence of false alarms. NOTE: Do not enable unless reporting, otherwise system trouble Fail to Communicate may occur. Number of Keypads in Area 1 • Enter the total number of Keypads to be installed in Area 1. • Valid entries are from 01 to 07. Directly enter the number of keypads, including leading zeros. Press U to save. Press the NEXT/YES button to proceed. Central Station Receiver 1 Telephone Number • Enter telephone number of up to 16 digits. • Press 1 through 9 for digits 1–9; G 0 for a zero and 0 for a blank (•). Central Phone # • Press G 1 through G 5 for letters B–F, respectively. • Pre-Dial Delay = “D” (G 4); Dial-Tone Detection = “E” (G 5). • Press U to save and press the NEXT/YES button to proceed. (Direct Entry) NOTE: Central Station Receiver 2 and 3 Telephone Numbers must be entered in Direct Address Programming. See CS Receiver Options. Central Station Receiver 1 Account Number • Enter an account number of up to four digits. • Press 0 through 9 for digits 0–9, and G 0 for a blank (•). Central Station Account # (____) • Press U to save and press the NEXT/YES button to proceed. (Direct Entry) NOTE: Central Station Receiver 2 and 3 Account Numbers must be entered in Direct Address Programming. See CS Reporting Options. See WI for Info Rcvr Format (0) • Press G1 through G4 for letters B–E. • Press U to save; press the NEXT/YES button to proceed. (Direct Entry) Enter user code-> U01 123 - 9User# User Code Central Station Receiver 1 Format • From the table at the right enter the receiver format. • Press 0 through 9, and G0 for blank (•). Area 1 DATA ENTRY • (blank) 2 3 4 5 B C E Enter User Codes (Press R to set cursor.) For default program, enter up to 16 User Codes, with Area 1 Options. • Press the (R) button once to set the cursor to the User Code. CS RECEIVER 1 FORMAT Ademco Slow, Silent Knight Slow Radionics Fast Silent Knight Fast Radionics, DCI, Franklin Slow Universal High Speed SIA Ademco Point ID Pager • Press 0 through 9 to enter a code from 3 to 6 digits, leave blank (•) any trailing boxes. • Press R to set the cursor to the Area 1 Options Level. Refer to the table below for available options. • If “Enable Global Ambush Code” (Address 1422) is enabled and “Global Ambush Code” (Address 2045) is not left blank (•), do not program the first two digits of ANY User Code the same as the “Global Ambush Code”. See Address 2045 further in this manual for more information. • Press U to save. Note: Duplicate User Codes are not allowed; therefore a duplicate Code entered in the LCD Window will erase when U is pressed. To proceed to the next User Code, press R to set the cursor to the User Number and change it using the number buttons. Press the NEXT/YES button to proceed. USER AREA OPTIONS USER OPTIONS USER CODE (UP TO 6 DIGITS) AREA 1 OPTIONS DATA ENTRIES L blank(•) R blank(•) blank(•) blank(•) blank(•) blank(•) blank(•) blank(•) 4 1 2 3 4 5 Add 8 blank(•) OPTION ENABLED Disabled Arm/Disarm Arm Only Service Access Ambush * User Program Bypass Enable Example: Program a code of “2222” for user 02, with area 1 options of “Arm/Disarm” and “User Program”. Enter “2222” for a user code, “• (blank) 9” for area 1 options. NAPCO Security Systems GEM-P816 Programming Instructions R Page 9 AREA OPTIONS Disabled Arm/Disarm Arm Only Service EXPLANATION User Code not active. Allows User Code to arm/disarm. Prevents User Code from disarming. A Service Code has restricted arm/disarm rights; if an area is armed with a Service Code, a “MONITOR ON” appears on the GEM-RP2ASe2 keypad and the area can be disarmed with any valid User Code, including a Service Code. If the area is armed with OTHER than a Service Code, it CANNOT be disarmed with a Service Code. This is typically used to allow tradesmen access to premises under control of the owner. There are two types of Ambush Codes: (1) A 2-digit code (prefix) that is entered immediately prior to (and as part of) the regular User Code and (2) A Ambush separate and unique User Code. Disarming with an Ambush Code will cause a silent report to be sent to a central station. Thus, should a user be forced to disarm, he can silently signal an emergency while appearing to be merely disarming the system. Access This is normally used to activate a door strike while an area is disarmed. Also program “Access Control on PGM2. Output” (Address 0719) and “PGM2 Output Access Control Timeout” (Address 0711). * User Program User Program Option is enabled. To enable User Program Option for any user, add 8 to the data entry for Area Option (see example). Then, User Programming can be performed at any Keypad by a user code with user program enabled. Bypass Enable Security Bypass--Bypass is enabled only with a security code. Related User Options:“Enable Global Ambush Code” (Address 1422), “Global Ambush Code” (Address 2045) & “Enable Manager's Mode” (Address 1421). CHANGING OR CANCELING A CODE: To change any code, merely program over the existing code as described above and press U to save. Similarly, to cancel a code, blank out each number of the code and press U to save. ZN# XMIT#+CS P Zn01- 000000:0-0 Zone # Mapped to Xmitter ID Check Sum Point # RF Transmitter Points (Press R to set cursor.) For each transmitter enter: (For wireless systems only. Also see Quick Method, which follows) • The zone number (01–16) to which the transmitter will be mapped. • The 6-digit RF ID # and 1-digit checksum number printed on the transmitter and box, • The point number (1 or 2); enter “9” for unsupervised (all points). • Press U to save and NEXT/YES button to proceed when all transmitters have been entered. NOTE: When programming the ID Code number, “0” through ”9” = 0 through 9 ; A = G 0 ; B = G 1 ; C = G 2 ; D = G 3 ; E = G 4 and “F” = G 5. Quick "Enroll" Method: If a receiver is already installed in the panel, transmitter wireless points can be programmed automatically (“enrolled”) using the following procedure. NOTE: The transmitter point will be enrolled only if ZN# X M I T # + C S P the signal strength is 3 or greater. Z n 0 1 - 0 0 0 0 0 0 : 0 - 0 1. Enter the zone number to which the transmitter point will be mapped. 2. Press B to enter the Enroll Mode. The red and green LEDs on the keypad will flash and the window will display as shown at left. ZN# X M I T # + C S P 3. Open the loop of the point that is to be programmed (GEM-TRANS2 only). Z N 0 1 - E N R O L L : A - - 4. Install the transmitter battery. The keypad will beep to indicate that the point has been successfully enrolled. Multi-point transmitters can be mapped to successive zones simultaneously. Example. A 2-point transmitter has the RF ID number 287613:1. 1 will be mapped to Zone 6). Map point 1 to Zone 6 and point 2 to Zone 9. 5. Enter Zone “09”. 1. Enter the Enroll mode as described above. 6. Close point-1 loop and open point-2 loop. 2. Enter Zone “06”. 7. Remove the transmitter battery, then re-install it. The keypad 3. Open point-1 loop. will beep once to indicate that one point has been pro4. Install the battery. The keypad will beep once to indicate that grammed. (Transmitter 287613:1, point 2 is mapped to Zone one point has been programmed. (Transmitter 287613:1, point 9). KEYFOB ZONE ASSIGNMENT: Keyfobs can also be assigned to zones to allow multiple wireless panic buttons on one alarm system, each reporting to a central station, a pager or having a description on the keypad that describes the person holding the keyfob, the location where the person holding the keyfob is stationed, or the special purpose of the keyfob button being depressed. See the next page on Keyfob Transmitters as Zone Input Devices . KF A XMIT#+CS OP 01-0 000000:0 00 KF # Area Xmitter ID Check Sum Aux 1&2 Keyfob Transmitters as Arm/Disarm & Control Devices (Press R to set cursor). Keyfobs can be programmed as “Arm/Disarm” devices using their On/Off buttons (refer to WI752). For each Keyfob Transmitter, enter: • The Keyfob Transmitter number (1–8). • The area number to which transmitter is assigned (1 or 0 to disable keyfob). • The 6-digit RF ID # and 1-digit checksum number printed on the transmitter and box, • The Aux 1 Option (see keyfob aux 1 & aux 2 options). • The Aux 2 Option (see keyfob aux 1 & aux 2 options). • Press U to save and NEXT/YES button to proceed when all keyfobs have been entered. NOTE: When programming the ID Code number, “0” through ”9” = 0 through 9 ; A = G 0 ; B = G 1 ; C = G 2 ; D = G 3 ; E = G 4 and “F” = G 5. NAPCO Security Systems R GEM-P816 Programming Instructions Page 10 Keyfob Transmitters as Zone Input Devices (Refer to display above: press the AWAY button to go backwards). Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point 3; A2 = point 4. Up to 16 keyfobs (using 1 button) or 8 keyfobs (using 2 buttons) or 4 keyfobs (using all 4 buttons) or any combination up to a maximum of 16 controlled zones can be assigned, providing multiple wireless panic buttons on a system, each reporting to a Central Station or a pager and/or annunciating on a keypad the keyfob zone number with a description. To assign a keyfob to a zone: program the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be hardwired to an electrical sensor as well as assigned to a keyfob (either one will activate the zone alarm output). NOTE: If assigning a keyfob to a zone, the “ON/OFF” buttons on the keyfob will no longer arm/disarm the system. The keyfob is converted to a “panic only” device. DATA ENTRY 0 1 2 9 A B C D E F AUX 1/AUX 2 OPTIONS None Relay Group 1 Toggle Relay Group 2 Toggle Keypad Panic Keypad Aux. Instant PGM2 Ouput Toggle Access on PGM2 Output Arm STAY Interior Button Enter Zone Descriptions • For each zone, enter a description of up to two lines. Press U to save each description. 01- • See page 41 for instructions for entering characters and numbers for the zone descriptions. • To proceed to the next description, place the cursor under the Zone Number (e.g. “1”) and (Direct Entry) press the number that corresponds to the zone. Program new description as above. NOTE: Zone Descriptions can only be entered through the GEM-RP1CAe2 Keypad or by using the Napco Quickloader Software. See Easy Menu Programming Worksheet for available zone description characters. Enter Date ( / / Enter Date (Press R to set cursor). • Enter the current date in the format MM/DD/YY. (MM = month, DD = day and YY = year. • Press U to save. Press the NEXT/YES button to proceed. ) (Direct Entry) Enter Time (Press R to set cursor.) Enter Time ( : • Enter the current time in format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59). • Select AM or PM by pressing any number button. • Press U to save. Press the NEXT/YES button to proceed. ) (Direct Entry) Dealer Code • Directly enter the Dealer Code (default = 456789), using 0 through 9 buttons. Dealer Code 456789 • Press U to save. Re-enter the Dealer Code to verify the previous code. Press U to save. • Press the NEXT/YES button to proceed. DEALER CODE RE-ENTER Test Timer • Select day(s) by simply erasing the unwanted days. Move the cursor over the day and press any number key to erase/restore the day. For example, "Monday" and "Friday" will appear as: "• M • • • F •" • Enter Time (in 24 hour format) by moving cursor under the left H and pressing two digits to overwrite the existing default of 00. Note: Midnight is 00:00. Enter minutes by continuing to enter data or if just updating minutes move the cursor under the left M and enter the two digits to overwrite the existing default of 00. Use R as right cursor one position. TEST TIMER SMTWTFS HH:MM EXIT DEALER PROGRAM MODE: This completes the custom default program. Press C to enter the Direct Address Program Mode for further programming or press C once again to end all programming and resume normal keypad operation. CLEAR PROGRAM: Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press C to enter the Address Program Mode; (b) access Location 2285 (Clear Program) or 2286 (Cold Start); (c) press U and then (d) press C to exit the Dealer Program Mode. A “SYSTEM TROUBLE/E09-00 SERVICE” will occur. Press C to silence the keypad. 2285 XX H Clear Dealer Program (Erases Dealer Program) Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descriptions. Access address 2285 and press U. Data entry is not allowed. NOTE: Enter Easy Menu Driven Program Mode to reprogram system. 2286 XX H Cold Start (Erases Entire Program) This erases all programmed data (Dealer Program, Zone Description Data and Schedules). Access address 2286 and press U. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software. NAPCO Security Systems GEM-P816 Programming Instructions R Page 11 DIRECT ADDRESS PROGRAM MODE DIRECT ADDRESS OVERVIEW Direct Address Programming allows you to go directly to the address locations (up to 2287) and change the data entries manually in order to customize your control panel options. Whereas the Easy Menu Program Mode guides you through limited selections to get you started, Direct Address Program Mode allows you to change all options directly. It consists of up to 2287 address locations each with data entry locations as shown in the following diagram (below left). The data entry location accepts data in one of three formats: Binary, Decimal and Hexadecimal (explained below in "Address Mode Displays"). The following diagram (below right) illustrates a Decimal format data entry location (using a GEM-RP1CAe2 keypad). ADDRESS LOCATIONS DATA ENTRY LOCATION GEM-RP1CAe2 Keypad Display Example 1 0000 0000 TO 2287 2 0000 060 DATA ENTRY LOCATION: (One of three formats): • Binary (Bit) • Decimal • Hexadecimal 1 2 D = ADDRESS LOCATION = DATA ENTRY LOCATION ADDRESS MODE DISPLAYS There are three types of address displays when programming in Direct Entry Program Mode, as follows: A) Binary (Bit) Format Example Settings (such as Zone Features) display and accept data in "number" format. For example, Zone Features are turned on by the pressing of keypad buttons 1 through 8, with the activated Zone(s) displaying the corresponding decimal digit (replacing deactivated zones which are signified by dashes). EXAMPLE: BIT Format with the GEM-RP1CAe2: Program Zones 2, 4, 5 and 7 as Exit/Entry Follower Zones. 0916 Address 0916 "Exit/Entry Follower" - - - - - - - - B DATA ENTRY LOCATION: Binary (Bit) Format • No zones yet activated DETERMINE THE DATA ENTRIES 0916 Address 0916 "Exit/Entry Follower" - 2 - 4 5 - 7 - B DATA ENTRY LOCATION: Binary (Bit) Format Press 2 4 5 and 7 in order to activate Zones 2, 4, 5, and 7. (The "B" on the right indicates "Binary" format). Because "bit numbers" range from 0-7, these "option numbers" 2,4,5 and 7 correspond to "bit numbers" 1,3,4 and 6, respectively. 1. Referring to ZONE FEATURES in the Programming Worksheets that follow, the Exit/Entry Follower for Zones 1 through 8 are located at address 0916. NAPCO Security Systems R GEM-P816 Programming Instructions Page 12 ZONES 1 ZONE FEATURES ADDR Z1 1 Exit/Entry Follower 8 ZONES 9 Z2 Z3 Z4 Z5 Z6 Z7 Z8 ADDR 2 3 4 5 6 6 7 7 8 8 0911 0916 16 Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 1 2 3 4 5 6 7 8 PROGRAM THE DATA ENTRIES 1. Enter the panel's Dealer Security Code, then press R. 2. Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B. 3. Press C to enter the Address Program Mode. Address "0000" will display. 4. Press 0916 to access Address 0916. The existing data will display and the cursor will advance to the data field. 5. Press 6 7 8. The numbers 6,7 and 8 will appear on the keypad display indicating the zones activated. 6. Press U to save. Address 0916 is now programmed with “6,7,8”. 7. Press R and enter another 4-digit address to continue programming --or-- press C to exit and resume normal keypad operation. B) Decimal Format Example Settings (such as Entry and Exit Delay) display and accept data in decimal format, as a 3 digit number. Data is entered directly, by pressing keys 0 – 9, with the cursor automatically moving to the right upon each key press. EXAMPLE: DECIMAL Format with the GEM-RP1CAe2: Program Abort Delay to be 15 seconds. 1417 - - - D DATA ENTRY LOCATION: Decimal Format Address 1417 "Abort Delay" • No time yet entered 1417 Address 1417 "Abort Delay" 015 D DATA ENTRY LOCATION: Decimal Format Press 0 1 5 in order to set "Abort Delay" to 15 seconds. The "D" on the right indicates "Decimal" format. DETERMINE THE DATA ENTRIES 1. Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Abort Delay is located at address 1417: ABORT ADDRESS 1417 DELAY (sec.) [Default = 0 sec. = blank (•)] PROGRAM THE DATA ENTRIES 1. Enter the panel's Dealer Security Code, then press R. 2. Answer NO to all questions until “ACTIVATE PROGRAM Y/N” is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B. 3. Press C to enter the Address Program Mode. Address "0000" will display. 4. Press 1417 to access Address 1417. The existing data will display and the cursor will NAPCO Security Systems GEM-P816 Programming Instructions R Page 13 advance to the data field. 5. Press 015. The numbers 015 will appear on the keypad display indicating the number of seconds entered. 6. Press U to save. Address 1417 is now programmed with a 15-second Abort Delay. 7. Press R and enter another 4-digit address to continue programming--or--press C to exit and resume normal keypad operation. C) Hexadecimal Format Example Data such as Report Codes displays and accepts data by means of a Hexadecimal display. Data is entered directly, by pressing keys 1 – 9, G0 for zero, and G 1 through G 5 for hex B through F (11-15), with the cursor automatically moving to the right upon key press. See table below. HEXADECIMAL ENTRIES ENTRY TOTAL PRESS N KEYPAD DISPLAYS ENTRY TOTAL PRESS N KEYPAD DISPLAYS blank 0 • 8 8 8 1 1 1 9 9 9 2 2 2 10 G 0 0 3 3 3 11 G 1 B 4 4 4 12 G 2 C 5 5 5 13 G 3 D 6 6 6 14 G 4 E 7 7 7 15 G 5 F EXAMPLE: HEXADECIMAL Format with the GEM-RP1CAe2: Program Chime Timeout to be 2 seconds. 1418 Address 1418 "Chime Timeout" - - H 1418 DATA ENTRY LOCATION: Decimal Format • No time yet entered Address 1418 "Chime Timeout" - 8 H DATA ENTRY LOCATION: Decimal Format Press 0 8 in order to set "Chime Timeout" to 2 seconds. The "H" on the right indicates "Hexadecimal" format. DETERMINE THE DATA ENTRIES 1. Referring to SYSTEM DELAYS & TIMEOUTS in the Programming Worksheets that follow, the Chime Timeout is located at address 1418. In the "Chime Timeout Options" table, the data entries needed to assign a timeout of 2 seconds are "blank" and "8". CHIME ADDRESS 1418 TIMEOUT (¼sec.) [Default = 2 ¼sec. = ½ sec.] NAPCO Security Systems R CHIME TIMEOUT OPTIONS DATA ENTRIES TIMEOUT LEFT RIGHT blank (•) blank (•) blank (•) 2 0 x ¼sec. = 0 sec. 2 x ¼sec. = ½ sec. blank (•) blank (•) blank (•) blank (•) blank (•) blank (•) 3 4 5 6 7 8 3 x ¼sec. = ¾ sec. 4 x ¼sec. = 1 sec. 5 x ¼sec. = 1.25 sec. 6 x ¼sec. = 1.5 sec. 7 x ¼sec. = 1.75 sec. 8 x ¼sec. = 2 sec. F F 255 x ¼sec. = 63.25 2 seconds GEM-P816 Programming Instructions Page 14 PROGRAM THE DATA ENTRIES 1. Enter the panel's Dealer Security Code, then press R. 2. Answer NO to all questions until "ACTIVATE PROGRAM Y/N" is displayed; then press YES. NOTE: If you pass “ACTIVATE PROGRAM”, scroll backward using B. 3. Press C to enter the Address Program Mode. Address "0000" will display. 4. Press 1418 to access Address 1418. The existing data will display and the cursor will advance to the data field. 5. Since you wish the timeout to be for 2 seconds (and 8 multiplied by ¼ second equals 2 seconds), press 08. The numbers 08 will appear on the keypad display indicating the number of seconds entered. 6. Press U to save. Address 1418 is now programmed with a 2-second chime. 7. Press R and enter another 4-digit address to continue programming --or-- press C to exit and resume normal keypad operation. PROGRAMMING CONVENTIONS USED IN THIS MANUAL The Keypad Programming Worksheets in the back are provided as an address-programming reference to help the installer modify his custom default program or to make minor field alterations to an existing panel program. It is recommended that the panel be uploaded to NAPCO's PCD-Windows software following any keypad programming and that the PCD-Windows's error-check feature be utilized to reduce the possibility of programming omissions or conflicts. 3 Keep the Keypad Programming Worksheets on file for future reference. General Programming Steps  1. Contact the central station to ascertain receiver format, data format, event codes, subscriber numbers and telephone number(s).  2. Select the desired features by circling the respective “address” boxes. Refer to the Programming Options and Worksheets for guidance in selecting the “data” to be entered into those boxes.  3. Program the data entered in the boxes on the worksheets into the respective addresses. The display will show the entry numerically, but if hexadecimal format will display “0” for the number 10, and letters “B”, “C”, “D”, “E”, and “F” for the numbers 11 through 15, respectively. To program a 10, press G 0. To program 11 through 15, press G 1 through G 5, respectively. The displays will appear after a brief delay.  Use R to toggle the cursor between the 4-digit address field and the data entry locations.  Enter the address directly using the number buttons.  The contents of the address will be read automatically. The cursor will advance to the data field. Enter the re- quired data directly using the number buttons.  IMPORTANT: Press U to save the contents of each address. EXIT DIRECT ADDRESS PROGRAM MODE: When done, press C to exit and resume normal keypad operation. NAPCO Security Systems GEM-P816 Programming Instructions R Page 15 SYST EM DE LAY S & TIMEOU TS (ADDR ESS 0000-000 2, 1413, 1417, 2050 & 2055) ADDRESS 0000 EXIT ENTRY ADDRESS 0001 ENTRY ADDRESS 0002 PGM2 Output ADDRESS 1413 ABORT DELAY DELAY 1 DELAY 2 Access Cntrl DELAY (sec.) (sec.) (sec.) Timeout (sec.) (sec.) [Default = 060]  [Default = 030] [Default = 030] [Default = 0 sec. = blank (•)] Select delay/timeout (0-255 sec.). [Default = 030] Sensor Watch EXIT/ENTRY DELAYS: Apply only to zones programmed with the following options “Exit/Entry 1, Exit/Entry 2, Exit/Entry Follower”. For UL Installations, the maximum exit delay is 60 seconds and the maximum entry delay is 45 seconds. NOTE: Sensor Watch Time Options are similar to above, except in hours. ADDRESS 1417 ADDRESS 2050 Time (Hrs.) [Default = 024]  Press U to save. Report Cancel ADDRESS 2055 Window (min.) [Default = 0 min. = blank (•)] WARNING: Timers have uncertainty of +/-1 sec, so a "time" of 1 second may actually timeout IMMEDIATELY. SYSTEM DE LAYS & TIM EOU TS (ADDRESS 1418-1419) CHIME ADDRESS 1418 AC Fail TIME Report Delay (¼sec.) (min.) [Default = 008 x ¼ sec. = 2 sec.] ADDRESS 1419 [Default = 060] DEFAULTS: The defaults shown on this page and on the following pages are automatically set after exiting the Easy Menu Driven Mode.  1. Enter delay/timeout in corresponding address locations above. Note: All entries for address 1418 are in quarter seconds (.25 seconds). Therefore, the default of 008 results in a 2 second timeout.  2. Press U to save. NAPCO Security Systems R GEM-P816 Programming Instructions Page 16 SYST EM OUTPU T TI MEOUTS (A D DRESS 141 2 & 14 14-1 4 16 ) ADDRESS 1412 PGM2 ADDRESS 1414 Alarm Output Output Timeout (min.) Timeout (min.) [Default = 0 min. = blank (•)] DATA DELAY/ ENTRIES TIMEOUT blank (•) 0 min. 001 1 min. 002 2 min. 003 3 min. 004 4 min. 005 5 min. 006 6 min. 016 16 min. 255 255 min. Pulse Alarm Output ADDRESS 1415 PGM1 Output Timeout (min.) [Default = 015] ADDRESS 1416 Timeout (min.) [Default = 015] [Default = 0 min. = blank (•)]  1. Select delay/timeout (0-255 min.) from the table shown.  2. Enter in corresponding address locations above.  3. Press U to save. OUTPUT TIMEOUTS: If a timeout of “0 min.” is selected, then the output will remain active (ON) until the system is reset or disarmed. For UL Residential Installations, the minimum timeout is 4 minutes. Not UL listed for Commercial Installations. DOWNL OAD/CAL LBACK OP TI ONS (ADDRESS 2059 & 0526-0545) No. Rings ADDRESS 2059 Before Pickup [Default = 015 ] NUMBER OF RINGS BEFORE PICKUP: Enter the number of rings before automatic pickup by the control panel when downloading from a computer (see Glossary at the back for more information).  1. Enter digit only.  2. Valid entries are: 003-015.  3. Press U to save. NOTE: Default is 15 Rings. ADDRESS 0526-0545 (RIGHT DIGITS 1-20) Callback Telephone Number (Digits 1-20) 0526 0527 0528 0529 0530 0531 0532 0533 0534 0535 0536 0537 0538 0539 0540 0541 0542 0543 0544 0545 [Default = blank (•) for all digits 1-20] CALLBACK TELEPHONE NUMBER: Enter telephone number to be used when downloading from a computer (see Glossary at the back for more information).  1. Enter digit only (right nibble).  2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•).  3. Valid entries are: 1-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = ignore location.  4. Press U to save. PAGER FOR MAT OP TION S (AD D RESS 05 46 & 0 54 7) Leading Digits for ADDRESS 0546 Pager Format (1st Digit) Leading Digits for ADDRESS 0547 Pager Format (2nd Digit) [Default = blank (•) blank (•)] LEADING DIGITS FOR PAGER FORMAT: In Pager Format reporting, the message typically begins with “00”. However, for some pager services, this will cause the Pager's Voice Mail feature to activate. This option allows you to program these digits to any number desired. A typical Pager report is “003 22 1234”, where 3 is the Event, 22 is the zone, and 1234 is the Subscriber ID number. For example, if the Leading Digits are programmed as “98”, the Pager report will now appear as “983 22 1234”. NOTE: See CS Receiver Options to select Pager Format. 1. Enter in 1st and 2nd Leading Digits as shown (right nibble). 2. Valid entries are: 0-9. Press U to save. NAPCO Security Systems GEM-P816 Programming Instructions R Page 17 SYSTEM OPT ION S (ADDR ESS 0836-0863 & 2045) GLOBAL SYSTEM EVENT/TROUBLE SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT/TROUBLE ADDR Alarm Output 0836 Pulsed Alarm Output 0837 PGM1 Output 0838 PGM2 Output 0839 Report Event Telco 1 0840 Report Restore Telco 1 0841 Report Event Telco 3 Report Restore Telco 3 0842 0843 TEST TIMER TELCO FAILURE RF RCVR. TROUBLE MEMORY FAILURE LOW BATTERY AC FAIL EZM TAMPER Bell Superv 1 2 3 4 5 6 7 8 Note: If Test Timer is enabled (above), Digital Dialer Test is also enabled. [Default = blank (•) from address 0836-0843]. AREA 1 SYSTEM EVENT/TROUBLE SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT/TROUBLE ADDR Pulsed Alarm Output 0856 Alarm Output 0857 PGM1 Output 0858 PGM2 Output 0860 Report Event Telco 1 Report Event Telco 3 0861 0863 AMBUSH KEYPAD PANIC KEYPAD FIRE KEYPAD AUX.‡ KEYPAD TAMPER FAIL TO OPEN FAIL TO CLOSE Keyfob Low Batt 1 2 3 4 5 6 7 8 [Default = blank (•) from address 0856-0863] ‡ NOTE: Keypad Aux. is not to be selected for UL Installations.  1. Select the desired option entering the option number (1-8) for each digit.  2. Enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available. Press U to save. ADDRESS 2045 Global 1st digit 2nd digit Ambush Code [Default = blank (•) blank (•)] GLOBAL AMBUSH CODE: It is the 2-digits entered immediately prior to the regular disarm code. If “Enable Global Ambush Code” (Address 1422) is selected and Address 2045 is left blank (•), then the 2-digit Global Ambush Code is “99”. If “Enable Global Ambush Code” is selected and Address 2045 is not left blank (•), then the 2-digit Global Ambush Code is the two digits entered in address 2045.   NAPCO Security Systems R Enter in address location (both 1st and 2nd digits); valid entries are 1-9. Press U to save. GEM-P816 Programming Instructions Page 18 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems GEM-P816 Programming Instructions R Page 19 SYSTEM OPT ION S (ADD RESS 1 4 20 -1 42 4, 2 05 1-2 054 ) 1420 System Options 1421 Option Default System Options Option Default OFF 1 Opening Report Only after Alarm Report OFF 1 Auto Bell Test on Arming OFF 2 Closing Report Only on Conditional Close OFF 2 Auto Reset after Burglary Output Timeout OFF 3 Incl. Sel./Grp. Bypass in Cond. Close /Status OFF 3 Suppress Bypass Reminder when Armed OFF OFF 4 Status Report 4 Enable Local Alarm on First Zone AND Trip 5 RESERVED OFF OFF 5 Access Control on PGM2 Output OFF 6 Enable AutoArm if not closed at end of Window OFF 6 Maintained Keyswitch Arming OFF 7 Enable Keypad Time/Date Display OFF 7 Enable Manager's Mode OFF 8 Disable Zone Fault Scrolling OFF 8 Disable Keypad Instant Mode 1422 System Options 1 2 3 4 5 6 7 8 OFF OFF OFF OFF OFF OFF OFF OFF 1423 Option Default Interior Normally Bypassed Enable Global Ambush Code ** OFF OFF Reset Day Zone with Arm/Disarm Only Enable Residential Fire Disable Keypad Function Mode Download OFF OFF OFF Disable Callback Download Chirp Output on Keyfob Arm/Disarm OFF OFF Change Pulse Output to Temporal Output§ OFF 2051 1424 System Options Option Default Automatic Interior Bypass/Easy Exit OFF 1 OFF 2 Veri-phone Zones Trip PGM2 Output OFF 3 4 Veri-phone Audio Priority Over Alarms OFF OFF OFF OFF ON Resound on Wireless Smoke Low Battery 5 Don't Clear PGM2 Output with Disarm 6 7 8 Disable 2nd Call Ans. Machine Override RESERVED Disable Code Required for EZ Bypass 2052 E15 Lug / System Options Option Default System Options Option Default Default OFF OFF OFF OFF OFF OFF OFF OFF 2053 1 2 3 4 5 6 7 8 1 RESERVED OFF 2 OFF Wireless Trouble Activates Telco 3 Enable Alarm Output on Telco Fail only when Armed Line-Fault Test only when Armed* Enable Line-Fault Test* Inhibit System Trouble Audible at Keypad‡ Select Alarm Output for Keyfob Chirp System Options 1 2 3 4 5 6 7 8 Option Enable Keypad Set Time/Date Message Enable Cancel Report to Telco 3 Disable [ON/OFF] as Easy Exit Enable GEM-PRINT Module RESERVED RESERVED Disable System Trouble Audible Timeout Enable "K Series" Style Keypads †† System Options Option Default OFF RESERVED Wireless Trouble Activates Telco 1 OFF 1 Exit Time Restart RESERVED OFF 2 Sound Alarm On Exit Error 3 Lug E15 Area 1 Armed Away Only***‡ OFF 3 Rpt Exit Err/Recent Close OFF OFF 4 PGM on RF Transmitter Tamper‡ Enable CP-01 Limits RESERVED OFF OFF 4 5 5 Digital Dialer Rpt Enter /Exit Test Mode OFF 6 RESERVED OFF 6 Disable Call Waiting on 1st Attempt OFF 7 RESERVED OFF 7 Enable Keypad 1 Only Programming OFF 8 RESERVED OFF 8 Enable CP-01 Egress Tones Only *NOTE: To select “Line-Fault Test only when Armed”, you must also select “Enable Line-Fault Test” at address 1423. **NOTE: If “Enable Global Ambush Code” in Address 1422 is selected, then program the 2-digit “Global Ambush Code” in Address 2045. If Address 2045 is left blank (•), then, the 2-digit “Global Ambush Code” will be “99”. ***Note: If this feature is not selected, the E15 Lug will, by default, activate when the system is armed (in either STAY or AWAY mode). ‡ Not for UL Installations †† For reference only and cannot be changed. § This feature must be programmed in Fire Alarm applications. NAPCO Security Systems R 2054 System Options Option Default ‡ OFF 1 OFF 2 Enable TCP/IP Communications RESERVED OFF 3 TCP/IP Panel/Site Initiated Functions OFF OFF 4 RESERVED 5 RESERVED OFF 6 RESERVED OFF 7 RESERVED OFF 8 RESERVED GEM-P816 Programming Instructions Page 20 CS RECEIVER OPTI ONS (ADDRE SS 0460-0 525) ADDRESS 0460 ADDRESS 0482 DATA ENTRY blank (•) 2 3 4 5 B C E ADDRESS 0504 CS Receiver 1 CS Receiver 2 CS Receiver 3 Format Format Format Default for CS Receiver 1 Format depends on Easy Menu Question “RCVR FORMAT”. [Default = •(blank) • (blank)] for CS Receivers 2 and 3 Formats. CS RECEIVER FORMATS: Up to 3 CS Formats may be programmed.  1. Select the desired CS Receiver Format from the table shown.  2. Enter the corresponding digit in the address location for each CS Receiver. NOTE: Dark shaded data value box shows option not available. Press [Enter] to save. 0461 CS Receiver Options - Telco 1 Option Default 0483 CS RECEIVER 1 FORMAT Ademco Slow, Silent Knight Slow Radionics Fast Silent Knight Fast Radionics, DCI, Franklin Slow Universal High Speed SIA Ademco Point ID Pager * NOTE: * See Pager Format Options to program Leading Digits for Pager Format. CS Receiver Options - Telco 2 Option Default OFF 1 1400Hz Handshake/Kissoff * OFF 1 1400Hz Handshake/Kissoff * OFF 2 2300Hz Handshake/Kissoff * OFF 2 2300Hz Handshake/Kissoff * OFF 3 Enable Zone Number on Pulse Alarm OFF 3 Enable Zone Number on Pulse Alarm OFF 4 Single Digit Only OFF 4 Single Digit Only OFF 5 Sum Check OFF 5 Sum Check OFF 6 3/1 with Extended Restores OFF 6 3/1 with Extended Restores OFF 7 Enable TCP/IP AES RPT OFF 7 Enable TCP/IP AES RPT OFF 8 RESERVED OFF 8 RESERVED 0505 CS Receiver Options - Telco 3 Option Default 1400Hz Handshake/Kissoff * OFF 1 OFF 2 2300Hz Handshake/Kissoff * OFF 3 Enable Zone Number on Pulse Alarm OFF 4 Single Digit Only OFF 5 Sum Check OFF 6 3/1 with Extended Restores OFF 7 Enable TCP/IP AES RPT OFF 8 RESERVED CS RECEIVER OPTIONS: Select options for any of the three CS Receivers.  1. Select the desired option entering the option number (1-8) for each digit.  2. Enter corresponding option number in address location (right nibble). NOTE: Dark shaded data value box shows option not available. Press [Enter] to save. *NOTE: If both are selected, 1400Hz has priority over 2300Hz. CS Receiver 1 ADDRESS 0462-0481 (RIGHT DIGITS 1-20) Telephone 0462 0463 0464 0465 0466 0467 0468 0469 0470 0471 0472 0473 0474 0475 0476 0477 0478 0479 0480 0481 Number (Digits 1-20) CS Receiver 2 ADDRESS 0484-0503 (RIGHT DIGITS 1-20) Telephone 0484 0485 0486 0487 0488 0489 0490 0491 0492 0493 0494 0495 0496 0497 0498 0499 0500 0501 0502 0503 Number (Digits 1-20) CS Receiver 3 ADDRESS 0506-0525 (RIGHT DIGITS 1-20) Telephone 0506 0507 0508 0509 0510 0511 0512 0513 0514 0515 0516 0517 0518 0519 0520 0521 0522 0523 0524 0525 Number Default for CS Receiver 1 Telephone Number depends on Easy Menu Question “ C E N T R A L PHONE #”. [Default = blank (•)] across digits 1-20 for CS Receiver Telephone Numbers 2 and 3. (Digits 1-20) CS RECEIVER TELEPHONE NUMBERS: Enter telephone numbers for any of the three CS Receivers (Telco 1, 2 & 3).  1. Enter digit only.  2. Enter up to 20 digits from left to right. NOTE: Leave trailing boxes blank (•). Press [Enter] to save.  3. Valid entries are: 1-9, B = *button, C = #button, D = 3 sec. pause, E = Wait for dial tone, F = Ignore location NAPCO Security Systems GEM-P816 Programming Instructions R Page 21 CS SUB SCRIBER ID OP TIONS (ADDRESS 0560-0 667) ADDRESS 0560-0563 CS Telco 1 Sub(RIGHT DIGITS 1-4) scriber Opening/ 0560 0561 0562 0563 Closing ID Number (Area 1) CS Telco 1 Subscriber Event ID Number (Area 1) ADDRESS 0576-0579 (RIGHT DIGITS 1-4) 0576 0577 0578 0579 ADDRESS 0592-0595 CS Telco 1 Sub(RIGHT DIGITS 1-4) scriber Event ID 0592 0593 0594 0595 Number (System) ADDRESS 0596-0599 CS Telco 2 Sub(RIGHT DIGITS 1-4) scriber Opening/ 0596 0597 0598 0599 Closing ID Number (Area 1) CS Telco 2 Subscriber Event ID Number (Area 1) ADDRESS 0612-0615 (RIGHT DIGITS 1-4) 0612 0613 0614 0615 ADDRESS 0628-0631 CS Telco 2 Sub(RIGHT DIGITS 1-4) scriber Event ID 0628 0629 0630 0631 Number (System) ADDRESS 0632-0635 CS Telco 3 Sub(RIGHT DIGITS 1-4) scriber Opening/ 0632 0633 0634 0635 Closing ID Number (Area 1) CS Telco 3 Subscriber Event ID Number (Area 1) ADDRESS 0648-0651 (RIGHT DIGITS 1-4) 0648 0649 0650 0651 ADDRESS 0664-0667 CS Telco 3 Sub(RIGHT DIGITS 1-4) scriber Event ID 0664 0665 0666 0667 Number (System) Default for CS Telco 1 Subscriber Event ID Number (Area 1) depends on Easy Menu Question “ACCOUNT #”. [Default = blank (•) blank (•) blank (•) blank (•)] for all other ID Numbers. CS TELCO SUBSCRIBER ID NUMBERS: Enter the Subscriber Opening/Closing and Event ID Numbers for any of the 3 CS Receivers.  1. Enter 3 or 4 digits (depending on the CS receiver format) for each subscriber number from left to right. NOTE: Leave trailing boxes blank (•).  2. Valid entries are: 1-9, 0 and B-F. NOTE: A is not permitted. Press [Enter] to save. NAPCO Security Systems R GEM-P816 Programming Instructions Page 22 CS SYS TEM RE P ORTIN G OPT ION S (ADDRES S 0670-0705) CS SYSTEM REPORTING CODES ADDRESS 0670-0682 CS SYSTEM REPORTING CODES ADDRESS 0683-0708 ADDR ADDR Alarm Restore Trouble Trouble Restore blank (•) blank (•) blank (•) 0670 0671 0672 Xmitter Low Battery Xmitter Supervision Xmitter Tamper blank (•) blank (•) blank (•) 0673 0674 0675 RESERVED blank (•) 0676 Opening Closing Opening after Alarm Conditional Close blank (•) blank (•) blank (•) blank (•) 0677 0678 0679 0680 Cancel Test Timer blank (•) 0681 0682 Tamper 0702 Fail to Open 0703 Fail to Close 0704 Keyfob Low Battery 0705 blank (•) Telco Fail RF Rec. Trouble 0683 Memory Fail 0685 NOTE: Left digit is the first digit and right digit is the second digit in a two digit CS receiver format. 0684 Low Battery 0686 Panel AC Fail 0687 EZM Tamper 0688 Alarm Output Superv. 0689 Ambush 0698 Panic 0699 Fire 0700 Auxiliary ‡ 0701 [Default = blank (•) blank (•) from address 0670-0682] [Default = blank (•) blank (•) from address 0683-0705] CS SYSTEM REPORTING CODES: 1. Enter in corresponding address location (left and right digits). 2. Valid entries are: 1-9, 0 and B-F. NOTE: A is not permitted. 3. To disable a code leave boxes blank (•). NOTE: Dark shaded data value box shows option not available. 4. Press U to save. ‡ NOTE: Keypad Aux. is not to be selected for UL Installations. CS AREA & SYS TEM RE POR TIN G OP TION S (ADD RESS 078 5, 07 86 & 0 788 ) RIGHT DATA VALUES DISABLE OPENING REPORTS ADDRESS 0785 LEFT DIGIT (CIRCLE ADDRESS 0786 AREA 1 2 LEFT DIGIT 4 blank (•) RIGHT DATA VALUES DISABLE CLOSING REPORTS ) 1 RIGHT DIGIT (SUM OF DATA VALUES) AREA (CIRCLE RIGHT DIGIT (SUM OF DATA VALUES) 1 AREA 1 2 4 blank (•) 8 AREA ) 8 [Default = blank (•) blank (•)] [Default = blank (•) blank (•)] OPENING REPORT OPTIONS:  1. Select the desired option by circling the data values for each digit (left and right).  2. Add the data values (ex: F=15=(1+2+4+8) from the selected options.  3. Enter in address location (left and right digits). See page 13). NOTE: Dark shaded data value box shows option not available. Press U to save. 0788 CS System Report Options Option Default OFF 1 OFF 2 Touch-tone Dialing Only * OFF 3 Touch-tone Dialing w/Rotary Backup * OFF 4 RESERVED OFF 5 Cancel Next Test Timer on any Report OFF 6 Disable Wait for Silence (Pager Format) OFF 7 Disable Wait for Handshake on Transmit OFF 8 Disable Auto Dial Tone Detect Backup Report on Telco 1 & 2 CS SYSTEM REPORTING OPTIONS:  1. Select the desired option entering the option number (1-8) for each digit.  2. Enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available.  3. Press U to save. * NOTE: If neither Touch-tone Dialing nor Touch-tone w/Rotary Backup is selected, then system defaults automatically to Rotary Dialing. Leave blank (•) to select Rotary Dialing. NAPCO Security Systems GEM-P816 Programming Instructions R Page 23 CS ZON E REP OR TING OP TI ONS (A DDRESS 07 2 0-0 735 ) ADDRESS 0720-0727 CONTROL PANEL ZONES REPORT CODE ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 0720 0721 0722 0723 0724 0725 0726 0727 ADDRESS 0728-0731 ZONES REPORT CODE ZONE 9 ZONE 10 ZONE 11 ZONE 12 0728 0729 0730 0731 ADDRESS 0732-0735 ZONES REPORT CODE ZONE 13 ZONE 14 ZONE 15 ZONE 16 0732 0733 0734 0735 Default for Group Zone Report Codes depends on Easy Menu Question “RCVR. FORMAT”. ZONE REPORT CODE OPTIONS DATA ENTRIES DATA ENTRIES LEFT MODEM CODE 1 2 3 4 7 8 0 B Fire Panic Burglary Hold up Gas Alarm Heat Alarm Auxiliary Alarm 24 Hour Auxiliary PULSE EVENT CODE will be the first digit of the 2 digit reporting code. The second digit will be the second digit of the reporting zone. For example, for zone 9 (address 0728), if the right digit is “3", then the reporting code is ”39". For example, for zone 15 (address 0734), if the right digit is “4", then the reporting code is ”45". MODEM CODES determine the zone types reported for the following formats: SIA and ADEMCO Point ID.  1. Select the desired Modem Code for each zone from the table shown.  2. Press U to save. NAPCO Security Systems R GEM-P816 Programming Instructions Page 24 CS USER REP OR TIN G OP TI ONS (ADDRESS 0800-0831) USERS 1 8 USERS 9 Enable Users to Report Opening and Closings Enable Opening Report, Telco 1 Enable Closing Report, Telco 1 Enable Opening Report, Telco 3 Enable Closing Report, Telco 3 ADDR U1 U2 U3 U4 U5 U6 U7 U8 Enable Users to Report Opening and Closings Enable Opening Report, Telco 1 Enable Closing Report, Telco 1 Enable Opening Report, Telco 3 Enable Closing Report, Telco 3 ADDR U33 U34 U35 U36 1 2 3 4 5 6 7 ADDR 8 0800 0809 0818 0827 16 U9 U10 U11 U12 U13 U14 U15 U16 1 2 3 4 5 6 7 8 0801 0810 0819 0828 USERS 33 1 2 3 4 5 36 6 7 0804 0813 0822 0831 8 User 33 = Auto Arming/Disarming User 34 = Quickloader Remote Arming/Disarming User 35 = Easy Arming (Opening not applicable) User 36 = Keyswitch Arming NOTE: These opening events will report as the user number shown. Also, Keyfobs 1-8 (see Easy Menu Program Driven Mode) will report as Users 9-16, respectively. CS USER REPORTING OPTIONS: [Default = blank (•) from address 0800-0831]  1.  2. Select the desired option entering the option number (1-8) for each digit.  3. Press U to save. At the keypad, enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems GEM-P816 Programming Instructions R Page 25 EZM GR OUP OP TION S (ADDRE S S 1455 & 1456) EZM Group 1 ADDRESS 1455 EZM Group 2 ADDRESS 1456 EZM TYPE DATA ENTRIES blank (•) 1 OPTION Not used (No EZM present) EZM GROUP ZONES COVERED NORMAL 1 9-12 2 13-16 4-Zone EZM NAPCO Security Systems R EZM GROUP OPTIONS: Up to 2 Groups of 4 Zones each may be programmed depending on the number of Zones used and which EZM modules are connected. Each Group represents 4 Zones.   1. Select EZM type from the table shown.  3. Press U to save. 2. Enter either blank (•) or "1" in corresponding address locations above. GEM-P816 Programming Instructions Page 26 AREA B ELL C ON TR OL OPTIONS (ADDRESS 1473, 1477, 1481, 1485) Output Turns Off upon Disarm 1473 Burglary Output Turns Off upon Disarm Default ON OFF 1 2 Option: Disarming: Burg Output Silenced RESERVED 1477 Default ON OFF Pulsed Burg Output Turns Off upon Disarm 1 2 Option: Disarming: Pulsed Burg Output Silenced RESERVED Silence PGM1 Output / PGM2 Output 1481 PGM1 Output Turns Off upon Disarm Default ON OFF 1 2 Option: Disarming: PGM1 Output Silenced RESERVED 1485 Default ON OFF PGM2 Output Turns Off upon Disarm 1 2 Option: Disarming: PGM2 Burg Output Silenced RESERVED OUTPUT TURNS OFF UPON DISARM: Select options for any of the 4 Outputs. By default, the ability to turn off an output upon disarm is not allowed. Enter digit in address location. NOTE: Dark shaded data value box shows option not available. Press U to save. NAPCO Security Systems GEM-P816 Programming Instructions R Page 27 KEYPAD OPTI ON S (A DDRES S 1425-1431, 1440-144 6) Enable Keypad Type & Activation ADDR Enable Keypad Type Blank (•) = Burg Keypad 2 = Wizard ‡ KEYPAD TYPE: Up to 7 keypads may be programmed, if they are connected. Keypad Area Assignment Blank (•) = Disabled 1 = Area 1 NOTE: See Keypad Configuration Mode. 1. Select keypad type for each keypad from the tables shown. ‡ Not for UL Installations Keypad 1 1425 Keypad 2 1426 Keypad 3 1427 Keypad 4 1428 Keypad 5 1429 Keypad 6 1430 Keypad 7 1431 2. Enter data in corresponding address locations. 3. Press U to save. [Default = blank (•) from address 1425-1431 Enable Keypad Options Enable Keypad Options ADDR Keypad 1 Options 1440 Keypad 2 Options 1441 Keypad 3 Options 1442 Keypad 4 Options 1443 Keypad 5 Options 1444 Keypad 6 Options 1445 Keypad 7 Options 1446 Keypad Fire Keypad Aux.‡ Keypad Panic 1 2 3 [Default = blank (•) from address 1440-1446] ‡ RSRVD Ambush 4 5 Easy Arming Panel Access RSRVD 6 7 8 NOTE: Keypad Aux. is not to be selected for UL Installations. ENABLE KEYPAD OPTIONS: Select options for any of the 7 keypads.  1.  2. Select the desired option entering the option number (1-8) for each digit.  3. Press U to save. At the keypad, enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available. NAPCO Security Systems R GEM-P816 Programming Instructions Page 28 TEMP ERATURE DISPLAY A T KEYPAD (ADDRES S 1666 -1668)  --ZONE 1666 Temperature Lower Limit 6 T E M P E R AT U R E S E N S O R - - ‡ 1667 Option Default Temperature Upper Limit ‡ Option Default OFF 1 Binary Temperature Value 1° OFF 1 Binary Temperature Value 1° OFF 2 Binary Temperature Value 2° OFF 2 Binary Temperature Value 2° OFF 3 Binary Temperature Value 4° OFF 3 Binary Temperature Value 4° OFF OFF 4 Binary Temperature Value 8° 4 Binary Temperature Value 8° 5 Binary Temperature Value 16° OFF OFF 5 Binary Temperature Value 16° OFF 6 Binary Temperature Value 32° OFF 6 Binary Temperature Value 32° OFF 7 Binary Temperature Value 64° OFF 7 Binary Temperature Value 64° OFF 8 Enable for Negative Temperature Value OFF 8 Enable for Negative Temperature Value 1668 ‡ Enable Temperature Options Option Default Enable Temperature Display Option OFF 1 OFF 2 Select Degrees Celsius OFF 3 Report Temperature Alarm (Zone 6) OFF OFF 4 Reserved 5 Reserved OFF 6 Reserved OFF 7 Reserved OFF 8 Reserved Temperature Display at Keypad The temperature is displayed instead of the date on line 2 of the GEM-RP1CAe2 (or GEM-K1CA) keypad. The keypad will display from –22F to 140F (or -30C to 60C). Fahrenheit is the default setting, select Celsius by enabling address 1668 option 2. When this Temperature Display Option is enabled, Zone 6 becomes the input for the GEM-TEMP64 Temperature Sensor module and Zone 6 of the panel becomes inoperative. Address 1668 option 3 enables Zone 6 to report a temperature problem. Address 1666 (options 1-7) set the lower limit temperature value and address 1667 (options 1-7) sets the upper limit temperature value (both values are set in binary). If the temperature detected by the panel is above or below these set limits, the panel will report an alarm on Zone 6. To function and report properly, Zone 6 must be selected as a reporting zone, 24hr zone in area 1 and auto-resetable. At both 1666 and 1667 addresses, option 8 sets positive or negative temperature. If the temperature of 0 degrees is required, "negative zero" (-0) degrees must be used (+0 or an empty location is not a valid temperature). To simulate the sensor module, a power supply can be connected to Zone 6 and set from .55v to 3.05v to display the whole temperature range. Temperature values are read and updated every 5 seconds. To report an outer limit temperature, the temperature must be out of limits for 2 seconds. To avoid false alarm reports, the limits have a threshold of 5 degrees in the software. Two new logs have been created for temperature out of limits and restore. If the G key is depressed and held down for 2 seconds, the date will display for 5 seconds. In addition, three addresses must be enabled (either via Quickloader or via direct address programming) in order for the Temperature Display at Keypad feature to operate. The following features must be enabled In Quickloader (or in direct address programming): 1. Keypad Assignment, Temperature Settings tab, Enable Temperature Display (Address 1668, option 1) 2. Keypad Assignment, Keypad Features tab, Enable Keypad Time/Date Display (Address 1420, option 7) 3. Keypad Assignment, Keypad Features tab, Enable Set Time/Date Message (Address 2051, option 1) Note: If these three addresses are set and power (AC and battery) are subsequently removed, they keypad will indicate that the time and date are lost and will need to be reset. See WI1425 for more information. ‡ This feature not evaluated by UL. NAPCO Security Systems GEM-P816 Programming Instructions R Page 29 ZONE OPTIONS - ZONE S 1 T O 16 (ADDRESS 0900-1016) ZONES 1 ZONE OPTIONS 50ms Loop Response (A) Priority Priority with Bypass Auto-Bypass Selective Bypass Keyswitch Arming Auto-Bypass Re-entry Pre-Alarm Warning Never Arm 24-Hour Zone Alarm Output Pulsed Alarm Output PGM1 Output PGM2 Output Entry/Exit 1 Entry/Exit 2 Exit/Entry Follower Auto Reset Swinger Shutdown Chime Abort Delay Power-up Delay Day Zone Open Day Zone Short Alarm on Day Zone Alarm Telco 1 Alarm Restore 1 Trouble Telco 1 Trouble Restore 1 Alarm Telco 3 Alarm Restore 3 Trouble Telco 3 Trouble Restore 3 No EOL Resistor Trouble on Open Trouble on Short Zone Area 1 RESERVED RESERVED RESERVED Interior (Stay) Bypass Keypad Sounder on Alarm 2-Wire Smoke Detectors (B) Fire (C) Fire Alarm Verification (C) RESERVED Zone ANDing Group 1 Zone ANDing Group 2 Zone ANDing Group 3 Zone ANDing Group 4 Sensor Watch RESERVED Chime 2 RESERVED RESERVED ADDR Z1 1 0900 0901 0902 0903 0904 0905 0906 0907 0908 0909 0910 0911 0912 0913 0914 0915 0916 0917 0918 0919 0920 0921 0922 0923 0924 0925 0926 0927 0928 0929 0930 0931 0932 0933 0934 0935 0936 0937 0938 0939 0940 0941 0942 0943 0944 0945 0946 0947 0948 0949 0950 0951 0952 0953 0954 Z2 2 Z3 3 Z4 4 Z5 5 8 Z6 6 ZONES 9 Z7 7 Z8 8 ADDR 16 Z9 Z10 Z11 Z12 Z13 Z14 Z15 Z16 1 2 3 4 5 6 7 8 0964 0965 0966 0967 0968 0969 0970 0971 0972 0973 0974 0975 0976 0977 0978 0979 0980 0981 0982 0983 0984 0985 0986 0987 0988 0989 0990 0991 0992 0993 0994 0995 0996 0997 0998 0999 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1010 1011 1012 1013 1014 1015 1016 1017 1018 When the Easy Program Menu is used, these features are enabled by default. Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). Disable Auto-Reset on non-fire zones for SIA CP-01 installations. ZONE OPTIONS: Select zone options for any zone. 1. Select the desired zone option by entering the option number (1-8) for each selected zone.   2. Enter corresponding option number in address location. NOTE: Dark shaded data value box shows option not available. Press [Enter] to save. NAPCO Security Systems R Notes A, B and C are located on the next page. GEM-P816 Programming Instructions Page 30 NOTES: (A) 50ms Loop Response only available for zones 1-8. For all other Zones, loop response is determined by jumpers on the GEM-EZM8 and/or keypad configuration on the GEM-RP1CAe2 or GEM-K1CA. (B) 2-wire Smoke Detectors only available for zones 7 & 8, and Fire must also be selected. (C) If Fire Alarm Verification is selected, then Fire must also be selected. DEFAULTS: The zone options indicated are automatically set after exiting the Easy Menu Driven Mode. • Priority, Selective Bypass, Alarm Output, Auto Reset, Swinger Shutdown and Zone Area 1 are enabled for the total number of zones entered in “# OF ZONES IN AREA1 ENTER # ZONES”. • Alarm Telco 1 is enabled for the zone number(s) entered in “REPORT ALL ZONES TO CENTRAL ZONES? Y/N”. • Entry/Exit 1 and Chime are enabled for the zone number(s) entered in “ENTRY/EXIT ZONES ENTER ZONE #”. • Exit/Entry Follower and Interior Bypass are enabled for the zone number(s) entered in “INTERIOR ZONES ENTER ZONE #”. • Pulse Alarm Output is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #” or “2-WIRE FIRE ZNS ENTER ZONE #”. • Fire is enabled for the zone number(s) entered in “FIRE ZONES ENTER ZONE #”. • 2-Wire Smoke Detector is enabled for the zone number(s) entered in “2-WIRE FIRE ZNS ENTER ZONE #”. NAPCO Security Systems GEM-P816 Programming Instructions R Page 31 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems R GEM-P816 Programming Instructions Page 32 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems GEM-P816 Programming Instructions R Page 33 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems R GEM-P816 Programming Instructions Page 34 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems GEM-P816 Programming Instructions R Page 35 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems R GEM-P816 Programming Instructions Page 36 RF RECEIVER & SUPERVIS ORY T IMER OPTI ONS (ADDRESS 2029-2044 & 2056) Number of RF Receivers ADDRESS 2056 LEFT DIGIT RIGHT DIGIT DATA ENTRIES RF RECEIVER(S) blank (•) None 1 2 1 2 blank (•) Default for Number of Receivers depends on Easy Menu Question for RF Transmitters. RF RECEIVERS: Up to 2 RF Receivers may be programmed.  1. Select the number of receivers from the table shown.  2. Enter number in address location shown.  3. Press U to save. RF SUPERVISORY TIMERS: RF Supervisory Timers may be programmed for each type of transmitter used. A transmitter will send a transmission every time it is tripped, when there is NO activity, the transmitter sends a status transmission about once an hour. If the receiver does NOT receive ANY signal (a trip or a status) from a transmitter in the time specified for transmitter type, a system trouble “WIRELESS TROUBLE/E04-NN SERVICE” will be displayed at the keypad. 1. Select timer delay from the table shown. Timers are programmed in increments of 30 minutes each. Valid entries are [3] through [F] (90 minutes-450 minutes). 2. 3. Enter in corresponding address locations below (right nibble). Press U to save. RF SUPERVISORY TIMER RF TRANSMITTER Type 0 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Type 8 Type 9 Type A Type B Type C Type D Type E Type F Window/Door, 2 Pt. Window/Door, 2 Pt. Window/Door, 2 Pt. Window/Door, 2 Pt. RESERVED PIR PIR Smoke Detector Smoke Detector RESERVED Dual Tech. RESERVED Window/Door, 4 Pt. PIR Smoke Detector Napco Glass Break ADDR RF SUPERVISORY DELAY TIME (Select timer delay from the table at right) 2029 2030 2031 2032 2034 2035 2036 2037 2039 2041 2042 2043 2044 RF SUPERVISORY TIMERS DATA ENTRIES DELAY 3 4 5 6 7 8 9 0 B C D E F 90 min. 120 min. 150 min. 180 min. 210 min. 240 min. 270 min. 300 min. 330 min. 360 min. 390 min. 420 min. 450 min. [Default = blank (•) from address 2029-2044]. Default = 8 (240 minutes) NOTE: These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy Menu Driven Mode Programming). NAPCO Security Systems GEM-P816 Programming Instructions R Page 37 C LEA R PR OGRA M OPTI ONS (AD DRESS 22 85 & 22 86) 2285 XX H Clear Dealer Program (Erases Dealer Program) This erases the dealer program. Use this feature to start a customized default program. Program Data and System Status Memory is erased where Scheduled Data and Zone Descriptions are maintained. Access address 2285, then press U. Data entry is not allowed. NOTE: again. 2286 XX H Enter Easy Menu Driven Program Mode to program system Cold Start (Erases Entire Program) This erases the entire program including Dealer Program by erasing Program Data, Zone Description Data and System Status Data (similar to a new panel). Access address 2286, then press U. Data entry is not allowed. NOTE: Some features (schedules) can only be programmed again with the Downloading Software. If power fails, time and date restarts at 00:00:00 and a date of 01-01-04 (January 1, 2004). USER PROGRAM MODE PRELIMINARY INFORMATION The User Program Mode is covered in detail in the operating instructions for the keypad in use.  The Program Mode cannot be accessed while the communicator is transmitting except during the first three minutes after powerup.  After entering codes or data, press the save U button. Data will not be stored into memory unless this button is pressed.  If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.  Press the C button to silence the sounder and exit the User Program Mode. NOTE: For ease of programming, it is recommended that a GEM K1CA (or GEM-RP1CAe2) be used. See Keypad Configuration Mode. If a GEM-RP2ASe2/GEM-K2AS keypad is used, see WI1182. NAPCO Security Systems R GEM-P816 Programming Instructions Page 38 ACCESSING USER PROGRAM MODE 1. Press EEEEEE R New Panel (Default User Code = 123) Existing Panel (Any Code with User Program Option Enabled) 2. Press Q Until "ACTIVATE PROGRAM Y/N" appears on LCD screen. 3. Press P To Enter User Program Mode 4. Press C To Exit User Program Mode when finished USER CODES User Code Enter user code U01 123 - 9- GEMINI Enter user code U01 123 - - To Program User Codes GEM-K1CAe2 Keypad (Direct Entry) Up to 16 User Codes may be programmed. NOTE: In this mode, only the code is programmable; the accompanying Area Options must be programmed in the Dealer Program Mode (see page 5). NOT USED 1. Set Cursor Position using the R button. 2. Enter 2-digit User Number (0116) directly using number buttons (0-9). 3. Enter Code (1-6 digits) directly using number buttons (0-9). 4. Press the U button to save ED ARM T ST A US U R 1 2 3 B 4 5 6 C 7 8 9 0 NEXT/YES P PRIOR/NO Q AREA G COMPUTERIZED SECURITY SYSTEM each code.  Use the R button to place the cursor over the User Number. NOTE: Press G 0 button to clear character at cursor.  Enter a User Number (01–16) using the number buttons. The cursor will then advance to the User Code and read the existing code, if any. To continue press P or Q button.  Enter the new User Code using the number buttons (0-9). Programming User Codes with GEM-K1CA Keypad If an old code is displayed, program over it. To erase the digit at the cursor, press G 0 button.  Press the U button to save the code in memory.  Repeat this procedure for each user. To proceed to Zone-Description programming, press the NEXT/YES button or the PRIOR/NO button. NAPCO Security Systems GEM-P816 Programming Instructions R Page 39 ZONE DESCRIPTIONS (GEM-RP1CAE2 / GEM-K1CA KEYPADS) 01PRESS: Enter an identifying description for each zone. Characters are selected by pressing keypad buttons multiple times, "Cell Phone" style. Buttons 1 through 9 plus 0 and G are used, as per the following table: (Direct Entry) CHARACTERS DISPLAYED IN SEQUENCE [1] HOLD G CHARACTERS DISPLAYED IN SEQUENCE AND PRESS: ABC1 [1] abc1 [2] DEF2 [2] def2 [3] GHI3 [3] ghi3 [4] JKL4 [4] jkl4 [5] MNO5 [5] mno5 [6] PQR6 [6] pqr6 [7] STU7 [7] stu7 [8] VWX8 [8] vwx8 [9] YZ90 [9] yz90 [0] (SPACE) • - . ( ) , / : ? # [0] (Reserved) Press [R] to move cursor right. Press [B] to move cursor left. Notes: 1. After releasing the number button for 2 seconds, the character will be accepted and the cursor advanced to the right. 2. After releasing the number button, if a new number button is pressed before the 2 second window expires, the current character will be accepted and the cursor automatically advanced to the right. The first of the 4 characters of this new number button will be displayed. 3. To erase an existing entry, use [R] or [B] to move the cursor below the character to be changed. Enter a new character to overwrite the old, or press zero to delete the character. 4. To generate lowercase characters, the [G] button must be pressed and held down while pressing the number button. If the G button is released during the 2 second window, the current character will change to uppercase. Press U to save. To advance to the next zone (or to any other zone), move the cursor to the displayed zone number (i.e., “01”) using and B. Change the zone number using keys 0 through 9. Enter two digits for the zone number (after entering the first digit, the cursor will automatically advance to the second digit). When the second zone number digit is entered, the cursor will automatically advance to the right, allowing the description locations to be entered. Always press U to save each zone description. R Enter Date ( / / ) (Direct Entry) Enter Time ( : ) (Direct Entry) Enter Date (Press the R button to set cursor.) Enter the current date in the format MM/DD/YY, where MM = the month (01–12); DD=the day (01–31); and YY=the year. Press U to save. Press NEXT button to proceed. Enter Time (Press the R button to set cursor.) Enter the current time in the format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59). Select AM or PM by pressing any number button, then press U once again to save. NOTE: To enter the date and time, GEM-RP1CAe2/GEM-K1CA keypad (version 9A or greater) must be used and “Enable Keypad Time/Date Display” (Address 1420) must be enabled. NAPCO Security Systems R GEM-P816 Programming Instructions Page 40 KEYPAD CONFIGURATION MODE This section will focus on configuring the GEM-RP1CAe2/GEM-K1CA Keypads. If there is more than one keypad in the system, we recommend that either a GEM-RP1CAe2 or a GEM-K1CA keypad be used for programming. KEYPAD INSTALLATION Several types of keypads may be used with the GEM-P816: the GEM-RP1CAe2/GEM-K1CA, the GEM-RP2ASe2/GEM-K2AS, the GEM-RP3DGTL/GEM-K3DGTL, and the GEM-RP4RFC/GEM-K4RF series (see WI1182). Each must be assigned an address number (1–7) and each requires its own configuration procedure (see CONFIGURING THE KEYPADS, which follows, and DIRECT ADDRESS KEYPAD AREA OPTIONS). At least 1 keypad must be used; only 1 is required for a single-area Commercial Burglary installation. GEM-RP1CAe2/GEM-K1CA - is a 2-line combination fire/burglary/access keypad capable of supporting 4 EZM zones and a PGM output. The GEM-RP1CAe2 or GEM-K1CA is recommended for programming. See "Important Note" on page 2 for more information regarding the buttons on the GEM-RP1CAe2/GEM-K1CA keypads. CONFIGURING THE KEYPADS A total of up to 7 keypads may be connected to the panel. GEM-RP1CAe2/GEM-K1CA, GEM-RP2ASe2/GEM-K2AS, GEMRP3DGTL/GEM-K3DGTL, and GEM-RP4RFC/GEM-K4RF series keypads may be intermixed but require different configuration procedures, as described below and in WI1182. Configuring the GEM-RP1CAe2/GEM-K1CA Keypad Each GEM-RP1CAe2/GEM-K1CA keypad must be configured for (a) keypad tactile beep; (b) entry sounder; (c) keypad address; (d) compatibility number; (e) EZM address; and (f) zone response. NORMAL To enter the Keypad Configuration Mode: 1. Move jumper JP1 (located in the center of the control panel board) from Pins 1-2 (top two) to Pins 2-3 (bottom KEYPAD CONFIGURE two). NOTE: See Wiring Diagram at the end of this manual. 2. After about 15 seconds, the display will read “XX OUT OF SYSTEM”, where XX indicates the keypad address. 3. Press 11123 R and proceed as follows. (Repeat the following procedure for all keypads). Keypad Tactile Beep Keypad Beep ON Upon entering the Keypad Configuration Mode, “KEYPAD BEEP ON” will be displayed, indicating that the tactile beep, which sounds when any button is pressed, is on. To turn off the tactile beep, press the U button (the U button will toggle the tactile beep on and off). Press R to continue or press C to exit. Entry Sounder Entry Sounder ON To turn off the keypad entry sounder during entry time, press U (the U button will toggle the entry sounder on and off). Press R to continue or press C to exit. Keypad Address 01 Keypad Address If more than one keypad is installed, each must be assigned a unique keypad address (that is, no two keypads may be numbered alike): Keypads must be numbered consecutively (missing numbers are not permitted) To assign the keypad number, proceed as follows: 1. Enter the assigned keypad number 01–07, then press U to save. A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press R to continue or press C to exit. NAPCO Security Systems GEM-P816 Programming Instructions R Page 41 New Compat # Compatibility Number (Not Applicable) 0000 THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P816 CONTROL PANEL. DO NOT CHANGE THIS SETTING. Press the R button to continue or press the C button to exit. EZM Address EZM Address The keypad's internal EZM (Expansion Zone Module) may be utilized to provide four additional wired zones. Whether used alone or in conjunction with optional GEM-EZM series modules or other keypad EZMs, it must be assigned a unique address (or Group number, see Keypad Programming Workbook) similar to its keypad address. If no other EZMs are to be used, designate the keypad as Group “01” at the “EZM ADDRESS 00” display. In multiple-EZM systems, enter an assigned group number “01” through “14”. (Each EZM must have a unique assigned group number, starting with “01” and proceeding consecutively.) Press the R button to continue or press the C button to exit. 01 Zone Response The normal loop response of each keypad expansion zone is 750mS, however the response time of any zone can be reduced to 50mS as follows. 1. Of the following, circle the number(s) in parentheses associated with the zone(s) to be changed: Zone 1=(1); Zone 2=(2); Zone 3=(4); Zone 4=(8) 2. Add up the circled numbers. 3. At the keypad, enter the sum as a two-digit number “01” through “15” on the display, then press U. Zone Response 00 Example. Change Zones 2, 3 and 4 to 50mS response. 1. Circle numbers for Zones 2, 3 and 4: (2), (4) and (8). 2. Add up the circled numbers: 2 + 4 + 8 = 14. 3. Enter “14” at the keypad, then press the U button. Press the R button to continue or press the C button to exit. Program Control Message (Not Applicable) Program Control Message # ? tion Mode (display will read “01 OUT OF NAPCO Security Systems R THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P816 CONTROL PANEL. Press the R button to continue (the display will loop back through selections, for changes) or press the C button to exit the Keypad ConfiguraSYSTEM”). Then replace Jumper JP1 across Pins 1–2 (top two). GEM-P816 Programming Instructions GEM-P816 Programming Instructions R 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 CODE (up to 6 digits) AREA 1 OPTIONS 4 = Radionics, DCI, Franklin Slow 3 = Silent Knight Fast 2 = Radionics Fast No E = Pager C = Ademco Point ID B = SIA 5 = Universal High Speed Zone 8 Yes No Area 1: # of Keypads (1-7) = Enter Interior Zones (1-16): __________ blank (•) = Ademco Slow, Silent Knight Slow Central Station Receiver 1 Format: Central Station Receiver 1 Account Number: User Codes: USER # No Central Station Receiver 1 Telephone Number: Report all Zones to Central?: Yes Enter Entry/Exit Zones (1-16): __________ Enter Fire Zones (1-16): __________ 2-Wire Fire Zones?: Zone 7 Yes Installer: Account Number: Area 1: # of Zones (1-16) = Address: Name: Page 42 EASY MENU PROGRAMMING WORKSHEET - 1 OF 3 NAPCO Security Systems Page 43 EASY MENU PROGRAMMING WORKSHEET - 2 OF 3 RF Transmitter Points: XMTR # ZONE # RF ID (printed on xmtr box) CHECK POINT SUM # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Keyfob Transmitters: KEYFOB # Area RF ID (printed on xmtr box) CHECK OPTION 1 OPTION 2 SUM 1 2 3 4 5 6 7 8 NAPCO Security Systems R GEM-P816 Programming Instructions Page 44 EASY MENU PROGRAMMING WORKSHEET - 3 OF 3 Zone Descriptions 1-16 ZN # CHARACTERS AVAILABLE (See below) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Characters Available for Zone Descriptions !@#$%^&*()_+!¦|{}[]`,.<>? 1234567890 abcedfghijklmnopqrstuvwxyz ABCDEFGHIJKLMNOPQRSTUVWXYZ Dealer Code: NAPCO Security Systems GEM-P816 Programming Instructions R Page 45 NOTES NAPCO Security Systems R GEM-P816 Programming Instructions Page 46 ALPHABETICAL INDEX 1400HZ HANDSHAKE/KISSOFF, ADDRESS 0461............................................. 20 1400HZ HANDSHAKE/KISSOFF, ADDRESS 0483............................................. 20 1400HZ HANDSHAKE/KISSOFF, ADDRESS 0505............................................. 20 2300HZ HANDSHAKE/KISSOFF, ADDRESS 0461............................................. 20 2300HZ HANDSHAKE/KISSOFF, ADDRESS 0483............................................. 20 2300HZ HANDSHAKE/KISSOFF, ADDRESS 0505............................................. 20 24 HOUR AUXILIARY (MODEM CODE) ............................................................... 23 24 HOUR ZONES IN AREA 1.................................................................................... 6 24-HOUR ZONE (ZONE OPTION), ADDRESS 0909, 0973 ............................... 29 2-WIRE FIRE ZONES IN AREA 1 ............................................................................. 6 2-WIRE SMOKE DETECTORS (ZONE OPTION), ADDRESS 0942................. 29 3/1 WITH EXTENDED RESTORES, ADDRESS 0461 ........................................ 20 3/1 WITH EXTENDED RESTORES, ADDRESS 0483 ........................................ 20 3/1 WITH EXTENDED RESTORES, ADDRESS 0505 ........................................ 20 50MS LOOP RESPONSE (ZONE OPTION), ADDRESS 0900, 0964 ............... 29 50MS LOOP RESPONSE ZONES ........................................................................... 7 ABORT DELAY (ZONE OPTION), ADDRESS 0920, 0984 ................................. 29 ABORT DELAY, ADDRESS 1417........................................................................... 15 AC FAIL REPORT DELAY, ADDRESS 1419 ........................................................ 15 ACCESS AREA OPTION ....................................................................................................... 9 ACCESS CONTROL ON PGM2 OUTPUT, ADDRESS 1421 ............................. 19 ACCESSING DEALER PROGRAM MODE............................................................. 5 ACTIVATE DOWNLOAD FUNCTION ...................................................................... 4 ADDRESS DISPLAYS TYPES ................................................................................................................... 11 ADDRESS MODE DISPLAYS ................................................................................. 11 ADEMCO POINT ID (CS RECEIVER 1 FORMAT) .............................................. 20 ADEMCO SLOW, SILENT KNIGHT SLOW (CS RECEIVER 1 FORMAT) ....... 20 ALARM ON DAY ZONE (ZONE OPTION), ADDRESS 0924, 0988 .................. 29 ALARM OUTPUT (ZONE OPTION), ADDRESS 0910, 0974 ............................. 29 ALARM OUTPUT SUPERV., ADDRESS 0689 ..................................................... 22 ALARM OUTPUT TIMEOUT, ADDRESS 1414 .................................................... 16 ALARM OUTPUT, ADDRESS 0836 ....................................................................... 17 ALARM OUTPUT, ADDRESS 0857 ....................................................................... 17 ALARM RESTORE 1 (ZONE OPTION), ADDRESS 0926, 0990 ....................... 29 ALARM RESTORE 3 (ZONE OPTION), ADDRESS 0930, 0994 ....................... 29 ALARM RESTORE, ADDRESS 0670 .................................................................... 22 ALARM TELCO 1 (ZONE OPTION), ADDRESS 0925, 0989 ............................. 29 ALARM TELCO 3 (ZONE OPTION), ADDRESS 0929, 0993 ............................. 29 AMBUSH AREA OPTION ....................................................................................................... 9 AMBUSH, ADDRESS 0698 ..................................................................................... 22 AREA BELL CONTROL OPTIONS (ADDRESS 1473-1485) .............................. 26 ARM ONLY AREA OPTION ....................................................................................................... 9 ARM/DISARM AREA OPTION ....................................................................................................... 9 AUTO BELL TEST ON ARMING, ADDRESS 1421..............................................19 AUTO BYPASS RE-ENTRY ZONES........................................................................ 7 AUTO RESET (ZONE OPTION), ADDRESS 0917, 0981 ...................................29 AUTO RESET AFTER BURGLARY OUTPUT TIMEOUT, ADDRESS 1421....19 AUTO-BYPASS (ZONE OPTION), ADDRESS 0903, 0967 ................................29 AUTO-BYPASS RE-ENTRY (ZONE OPTION), ADDRESS 0906, 0970 ...........29 AUTOMATIC INTERIOR BYPASS/EASY EXIT, ADDRESS 1424.....................19 AUX OUTPUT ACTIVATED ON ALARM ZONES .................................................. 7 AUXILIARY ALARM (MODEM CODE) ...................................................................23 AUXILIARY, ADDRESS 0701 ..................................................................................22 BACKUP REPORT ON TELCO 1 & 2, ADDRESS 0788 .....................................22 BINARY (BIT) FORMAT EXAMPLE........................................................................11 BIT FORMAT EXAMPLE .............................................................................................................11 BURGLARY (MODEM CODE) ................................................................................23 BURGLARY OUTPUT TURNS OFF UPON DISARM, ADDRESS 1473 ..........26 BYPASS ENABLE AREA OPTION ....................................................................................................... 9 CALLBACK METHOD................................................................................................. 4 CALLBACK TELEPHONE NUMBER, ADDRESS 0526-0545 ............................16 CANCEL A CODE ....................................................................................................... 9 CANCEL NEXT TEST TIMER ON ANY REPORT, ADDRESS 0788 ................22 CANCEL, ADDRESS 0681 ......................................................................................22 CENTRAL STATION RECEIVER 1 ACCOUNT NUMBER ................................... 8 CENTRAL STATION RECEIVER 1 FORMAT ........................................................ 8 CENTRAL STATION RECEIVER 1 TELEPHONE NUMBER ............................... 8 CHANGE PULSE OUTPUT TO TEMPORAL OUTPUT, ADDRESS 1422 .......19 CHANGING OR CANCELING A CODE................................................................... 9 CHIME (ZONE OPTION), ADDRESS 0919, 0983 ................................................29 CHIME 2 (ZONE OPTION), ADDRESS 0952, 1016.............................................29 CHIME 2 ZONES IN AREA 1 ..................................................................................... 7 CHIME TIME, ADDRESS 1418 ...............................................................................15 CHIME ZONES IN AREA 1 ........................................................................................ 7 CHIRP OUTPUT ON KEYFOB ARM/DISARM, ADDRESS 1422 ......................19 CLEAR DEALER PROGRAM EASY MENU.........................................................................................................10 CLEAR DEALER PROGRAM, ADDRESS 2285...................................................37 CLOSING REPORT ..................................................................................................24 CLOSING REPORT ONLY ON CONDITIONAL CLOSE, ADDRESS 1420 .....19 CLOSING, ADDRESS 0678.....................................................................................22 COLD START EASY MENU.........................................................................................................10 COLD START, ADDRESS 2286 .............................................................................37 COMPATIBILITY NUMBER .....................................................................................41 CONDITIONAL CLOSE, ADDRESS 0680 .............................................................22 CONFIGURING THE KEYPADS.............................................................................40 CONTROL PANEL FIRMWARE VERSION............................................................. 2 CREATE A CUSTOM PROGRAM ............................................................................ 6 NAPCO Security Systems GEM-P816 Programming Instructions R Page 47 ALPHABETICAL INDEX (CONT'D) CS AREA & SYSTEM REPORTING OPTIONS (ADDRESS 0785, 0786 & 0788) ...................................................................................................................................... 22 CS RECEIVER 1 FORMAT, ADDRESS 0460 ...................................................... 20 CS RECEIVER 1 TELEPHONE NUMBER, ADDRESS 0462-0481................... 20 CS RECEIVER 2 FORMAT, ADDRESS 0482 ...................................................... 20 CS RECEIVER 2 TELEPHONE NUMBER, ADDRESS 0484-0503................... 20 CS RECEIVER 3 FORMAT, ADDRESS 0504 ...................................................... 20 CS RECEIVER 3 TELEPHONE NUMBER, ADDRESS 0506-0525................... 20 CS RECEIVER OPTIONS - TELCO 1, ADDRESS 0461 ..................................... 20 CS RECEIVER OPTIONS - TELCO 2, ADDRESS 0483 ..................................... 20 CS RECEIVER OPTIONS - TELCO 3, ADDRESS 0505 ..................................... 20 CS SUBSCRIBER ID OPTIONS (ADDRESS 0560-0667)................................... 21 CS SYSTEM REPORT OPTIONS, ADDRESS 0788 ........................................... 22 CS SYSTEM REPORTING CODES, ADDRESS 0683-0708.............................. 22 CS TELCO SUBSCRIBER ID NUMBERS ............................................................. 21 CS USER REPORTING OPTIONS (ADDRESS 0800-0831).............................. 24 CS ZONE REPORTING OPTIONS (ADDRESS 0720-0735).............................. 23 CURRENT TIME........................................................................................................ 10 CUSTOM DEFAULT PROGRAM ............................................................................. 5 CUSTOMIZING A DEFAULT PROGRAM ............................................................... 5 DATE ........................................................................................................................... 10 DAY ZONE OPEN (ZONE OPTION), ADDRESS 0922, 0986 ............................ 29 DAY ZONE SHORT (ZONE OPTION), ADDRESS 0923, 0987 ......................... 29 DEALER CODE ......................................................................................................... 10 DEFAULT ................................................................................................................ 5 DEALER PROGRAM - PRELIMINARY INFORMATION ....................................... 5 DEALER PROGRAM MODE ..................................................................................... 4 DEALER PROGRAM MODE ACCESSING........................................................................................................... 5 DECIMAL FORMAT EXAMPLE ............................................................................................................. 12 DECIMAL FORMAT EXAMPLE .............................................................................. 12 DEFAULT DEALER CODE ........................................................................................ 5 DIGITAL DIALER RPT ENTER /EXIT TEST MODE, ADDRESS 2053 ............. 19 DIRECT ADDRESS OVERVIEW ............................................................................ 11 DIRECT ADDRESS PROGRAM MODE .................................................................. 4 DIRECT ADDRESS PROGRAM MODE ................................................................ 11 DISABLE [ON/OFF] AS EASY EXIT, ADDRESS 2051 ........................................ 19 DISABLE 2ND CALL ANS. MACHINE OVERRIDE, ADDRESS 1424 .............. 19 DISABLE AUTO DIAL TONE DETECT, ADDRESS 0788................................... 22 DISABLE CALL WAITING ON 1ST ATTEMPT, ADDRESS 2053 ...................... 19 DISABLE CALLBACK DOWNLOAD, ADDRESS 1422 ....................................... 19 DISABLE CLOSING REPORTS, ADDRESS 0786 .............................................. 22 DISABLE CODE REQUIRED FOR EZ BYPASS, ADDRESS 1424................... 19 DISABLE KEYPAD FUNCTION MODE DOWNLOAD, ADDRESS 1422 ......... 19 DISABLE KEYPAD INSTANT MODE, ADDRESS 1421 ..................................... 19 DISABLE OPENING REPORTS, ADDRESS 0785 .............................................. 22 DISABLE SYSTEM TROUBLE AUDIBLE TIMEOUT, ADDRESS 2051 ........... 19 DISABLE WAIT FOR HANDSHAKE ON TRANSMIT, ADDRESS 0788 ........... 22 NAPCO Security Systems R DISABLE WAIT FOR SILENCE (PAGER FORMAT), ADDRESS 0788 ............22 DISABLE ZONE FAULT SCROLLING, ADDRESS 1420 ....................................19 DISABLED AREA OPTION ....................................................................................................... 9 DON'T CLEAR PGM2 OUTPUT WITH DISARM, ADDRESS 1424 ...................19 DOWNLOAD/CALLBACK OPTIONS (ADDRESS 2059 & 0526-0545) .............16 DOWNLOADING FROM A COMPUTER ................................................................. 4 EASY MENU DRIVEN PROGRAM MODE.............................................................. 5 EASY MENU PROGRAMMING WORKSHEET ......................................42, 43, 44 EASY MENU-DRIVEN PROGRAM .......................................................................... 4 ENABLE "K SERIES" STYLE KEYPADS, ADDRESS 2051 ...............................19 ENABLE ALARM OUTPUT ON TELCO FAIL ONLY WHEN ARMED, ADDRESS 1423 ..............................................................................................................19 ENABLE AUTOARM IF NOT CLOSED AT END OF WINDOW, ADDRESS 1420 ......................................................................................................................................19 ENABLE BURG OUTPUT CHIRP ON KEYFOB .................................................... 8 ENABLE CANCEL REPORT TO TELCO 3, ADDRESS 2051 ............................19 ENABLE CP-01 EGRESS TONES ONLY, ADDRESS 2053 ..............................19 ENABLE CP-01 LIMITS, ADDRESS 2053 .............................................................19 ENABLE GEM-PRINT MODULE, ADDRESS 2051 .............................................19 ENABLE GLOBAL AMBUSH CODE, ADDRESS 1422 .......................................19 ENABLE KEYPAD 1 ONLY PROGRAMMING, ADDRESS 2053 ......................19 ENABLE KEYPAD OPTIONS, ADDRESS 1440-1446.........................................27 ENABLE KEYPAD SET TIME/DATE MESSAGE, ADDRESS 2051 ..................19 ENABLE KEYPAD TIME/DATE DISPLAY, ADDRESS 1420 ..............................19 ENABLE KEYPAD TYPE & ACTIVATION, ADDRESS 1425-1431....................27 ENABLE LINE-FAULT TEST, ADDRESS 1423 ....................................................19 ENABLE LOCAL ALARM ON FIRST ZONE AND TRIP, ADDRESS 1421 .......19 ENABLE MANAGER'S MODE, ADDRESS 1421 .................................................19 ENABLE NO EOLR ZONES ...................................................................................... 7 ENABLE RESIDENTIAL FIRE, ADDRESS 1422 ..................................................19 ENABLE SIA CP-01 FEATURES .............................................................................. 8 ENABLE TCP/IP AES RPT, ADDRESS 0461 ............................................. 20 ENABLE TCP/IP AES RPT, ADDRESS 0483 ............................................. 20 ENABLE TCP/IP AES RPT, ADDRESS 0505 ............................................. 20 ENABLE TCP/IP COMMUNICATIONS, ADDRESS 2054 ...................................19 ENABLE TELCO LINE FAULT TEST ....................................................................... 7 ENABLE TEMPERATURE DISPLAY OPTION, ADDRESS 1668......................28 ENABLE USERS TO REPORT OPENING AND CLOSINGS.............................24 ENABLE ZONE NUMBER ON PULSE ALARM, ADDRESS 0461.....................20 ENABLE ZONE NUMBER ON PULSE ALARM, ADDRESS 0483.....................20 ENABLE ZONE NUMBER ON PULSE ALARM, ADDRESS 0505.....................20 ENTER DATE.......................................................................................................10, 39 ENTER TIME ........................................................................................................10, 39 ENTER USER CODES ............................................................................................... 8 ENTER ZONE DESCRIPTIONS .............................................................................10 ENTRY DELAY 1, ADDRESS 0001 ........................................................................15 ENTRY DELAY 2, ADDRESS 0002 ........................................................................15 ENTRY/EXIT 1 (ZONE OPTION), ADDRESS 0914, 0978 ..................................29 GEM-P816 Programming Instructions Page 48 ALPHABETICAL INDEX (CONT'D) ENTRY/EXIT 2 (ZONE OPTION), ADDRESS 0915, 0979 .................................. 29 ERASE DEALER PROGRAM, ADDRESS 2285 .................................................. 37 ERASE ENTIRE PROGRAM, ADDRESS 2286.................................................... 37 ERASING DEALER PROGRAM EASY MENU......................................................................................................... 10 ERASING ENTIRE PROGRAM EASY MENU......................................................................................................... 10 EXIT DEALER PROGRAM MODE ......................................................................... 10 EXIT DELAY, ADDRESS 0000................................................................................ 15 EXIT TIME RESTART, ADDRESS 2053................................................................ 19 EXIT/ENTRY FOLLOWER (ZONE OPTION), ADDRESS 0916, 0980 .............. 29 EXIT/ENTRY ZONES IN AREA 1 ............................................................................. 6 EXIT/ENTRY2 ZONES IN AREA 1 ........................................................................... 7 EZM ADDRESS ......................................................................................................... 41 EZM GROUP OPTIONS (ADDRESS 1455-1456) ................................................ 25 EZM TAMPER, ADDRESS 0688 ............................................................................ 22 FAIL TO CLOSE, ADDRESS 0704 ......................................................................... 22 FAIL TO OPEN, ADDRESS 0703 ........................................................................... 22 FIRE (MODEM CODE) ............................................................................................. 23 FIRE (ZONE OPTION), ADDRESS 0943, 1007.................................................... 29 FIRE ALARM VERIFICATION (ZONE OPTION), ADDRESS 0944, 1008 ........ 29 FIRE ZONES IN AREA 1 ............................................................................................ 6 FIRE, ADDRESS 0700 ............................................................................................. 22 FIRMWARE VERSION ............................................................................................... 2 FUNCTION MODE ...................................................................................................... 4 GAS ALARM (MODEM CODE) ............................................................................... 23 GEM-P816 WIRING DIAGRAM............................................................................... 56 GEM-RP1CAE2/GEM-K1CA KEYPAD EASY PROGRAM MENU ...................... 6 GLOBAL AMBUSH CODE, ADDRESS 2045 ........................................................ 17 HEAT ALARM (MODEM CODE)............................................................................. 23 HEXADECIMAL FORMAT EXAMPLE ............................................................................................................. 13 HEXADECIMAL FORMAT EXAMPLE ................................................................... 13 HOLD UP (MODEM CODE) .................................................................................... 23 INCL. SEL./GRP. BYPASS IN COND. CLOSE /STATUS, ADDRESS 1420 .... 19 INHIBIT SYSTEM TROUBLE AUDIBLE AT KEYPAD, ADDRESS 1423 .......... 19 INTERIOR (STAY) BYPASS (ZONE OPTION), ADDRESS 0940, 1004 ........... 29 INTERIOR NORMALLY BYPASSED, ADDRESS 1422 ...................................... 19 INTERIOR ZONES IN AREA 1 .................................................................................. 6 K SERIES KEYPAD PROGRAMMING .................................................................... 2 KEYFOB TRANSMITTERS AS ARM/DISARM & CONTROL DEVICES ............ 9 KEYFOB TRANSMITTERS AS ZONE INPUT DEVICES.................................... 10 KEYFOB LOW BATTERY, ADDRESS 0705 ......................................................... 22 KEYPAD CONFIGURING.................................................................................................... 40 KEYPAD ADDRESS ................................................................................................. 40 KEYPAD CONFIGURATION MODE ...................................................................... 40 KEYPAD ENTRY SOUNDER .................................................................................. 40 KEYPAD INSTALLATION ........................................................................................40 KEYPAD OPTIONS (ADDRESS 1425-1431, 1440-1446) ...................................27 KEYPAD SOUNDER ON ALARM (ZONE OPTION), ADDRESS 0941, 1005..29 KEYPAD SOUNDER ON ALARM ZONES .............................................................. 7 KEYPAD TACTILE BEEP.........................................................................................40 KEYSWITCH ARMING (ZONE OPTION), ADDRESS 0905, 0969 ....................29 LEADING DIGITS FOR PAGER FORMAT (1ST DIGIT), ADDRESS 0546 ......16 LEADING DIGITS FOR PAGER FORMAT (2ND DIGIT), ADDRESS 0547......16 LINE-FAULT TEST ONLY WHEN ARMED, ADDRESS 1423 ............................19 LOCAL DOWNLOADING ........................................................................................... 4 LOCAL OR CENTRAL STATION REPORTING SYSTEM.................................... 6 LOW BATTERY, ADDRESS 0686 ..........................................................................22 LUG E15 AREA 1 ARMED AWAY ONLY, ADDRESS 2052 ...............................19 MAINTAINED KEYSWITCH ARMING, ADDRESS 1421 ....................................19 MEMORY FAIL, ADDRESS 0685 ...........................................................................22 MODEM CODES .......................................................................................................23 NEVER ARM (ZONE OPTION), ADDRESS 0908, 0972 .....................................29 NEW PANELS.............................................................................................................. 5 NO EOL RESISTOR (ZONE OPTION), ADDRESS 0933, 0997 ........................29 NO. RINGS BEFORE PICKUP, ADDRESS 2059.................................................16 NUMBER OF KEYPADS IN AREA 1 ........................................................................ 8 NUMBER OF RINGS BEFORE PICKUP, ADDRESS 2059 ................................16 OPENING AFTER ALARM, ADDRESS 0679 .......................................................22 OPENING REPORT ..................................................................................................24 OPENING REPORT ONLY AFTER ALARM REPORT, ADDRESS 1420 ........19 OPENING, ADDRESS 0677 ....................................................................................22 OUT OF SYSTEM .....................................................................................................40 PAGER (CS RECEIVER 1 FORMAT) ....................................................................20 PAGER FORMAT OPTIONS (ADDRESS 0546 & 0547).....................................16 PANEL AC FAIL, ADDRESS 0687..........................................................................22 PANIC (MODEM CODE) ..........................................................................................23 PANIC, ADDRESS 0699 ..........................................................................................22 PGM ON RF TRANSMITTER TAMPER, ADDRESS 2052 .................................19 PGM1 OUTPUT (ZONE OPTION), ADDRESS 0912, 0976 ................................29 PGM1 OUTPUT TIMEOUT, ADDRESS 1416 .......................................................16 PGM1 OUTPUT TURNS OFF UPON DISARM, ADDRESS 1481 .....................26 PGM1 OUTPUT, ADDRESS 0838 ..........................................................................17 PGM1 OUTPUT, ADDRESS 0858 ..........................................................................17 PGM2 OUTPUT (ZONE OPTION), ADDRESS 0913, 0977 ................................29 PGM2 OUTPUT ACCESS CNTRL TIMEOUT, ADDRESS 1413 .......................15 PGM2 OUTPUT TIMEOUT, ADDRESS 1412 .......................................................16 PGM2 OUTPUT TURNS OFF UPON DISARM, ADDRESS 1485 .....................26 PGM2 OUTPUT, ADDRESS 0839 ..........................................................................17 PGM2 OUTPUT, ADDRESS 0860 ..........................................................................17 POWER-UP DELAY (ZONE OPTION), ADDRESS 0921, 0985 .........................29 PRE-ALARM WARNING (ZONE OPTION), ADDRESS 0907, 0971 .................29 PRIORITY (ZONE OPTION), ADDRESS 0901, 0965 ..........................................29 PRIORITY WITH BYPASS (ZONE OPTION), ADDRESS 0902, 0966 ..............29 NAPCO Security Systems GEM-P816 Programming Instructions R Page 49 ALPHABETICAL INDEX (CONT'D) PROGRAM CONTROL MESSAGE........................................................................ 41 PROGRAMMING CONVENTIONS ........................................................................ 14 PROGRAMMING STEPS GENERAL ............................................................................................................. 14 PROGRAMMING WITH THE K SERIES KEYPADS ............................................. 2 PULSE ALARM OUTPUT TIMEOUT, ADDRESS 1415 ...................................... 16 PULSE EVENT CODE.............................................................................................. 23 PULSED ALARM OUTPUT (ZONE OPTION), ADDRESS 0911, 0975............. 29 PULSED ALARM OUTPUT, ADDRESS 0837 ...................................................... 17 PULSED ALARM OUTPUT, ADDRESS 0856 ...................................................... 17 PULSED BURG OUTPUT TURNS OFF UPON DISARM, ADDRESS 1477.... 26 QUICK METHOD......................................................................................................... 9 RADIONICS FAST (CS RECEIVER 1 FORMAT) ................................................. 20 RADIONICS, DCI, FRANKLIN SLOW (CS RECEIVER 1 FORMAT)................. 20 RELAY MODULE RM3008 ...................................................................................... 34 REMOTE DOWNLOADING ....................................................................................... 4 REPORT CANCEL WINDOW, ADDRESS 2055 .................................................. 15 REPORT EVENT TELCO 1, ADDRESS 0840 ...................................................... 17 REPORT EVENT TELCO 1, ADDRESS 0861 ...................................................... 17 REPORT EVENT TELCO 3, ADDRESS 0842 ...................................................... 17 REPORT EVENT TELCO 3, ADDRESS 0863 ...................................................... 17 REPORT OPENING AND CLOSINGS................................................................... 24 REPORT RESTORE TELCO 1, ADDRESS 0841 ................................................ 17 REPORT RESTORE TELCO 3, ADDRESS 0843 ................................................ 17 REPORT TEMPERATURE ALARM (ZONE 6), ADDRESS 1668 ...................... 28 RESET DAY ZONE WITH ARM/DISARM ONLY, ADDRESS 1422 .................. 19 RESOUND ON WIRELESS SMOKE LOW BATTERY, ADDRESS 1424 ......... 19 RF REC. TROUBLE, ADDRESS 0684 ................................................................... 22 RF RECEIVER & SUPERVISORY TIMER OPTIONS (ADDRESS 2029-2044 & 2056)............................................................................................................................ 36 RF TRANSMITTER POINTS ..................................................................................... 9 RPT EXIT ERR/RECENT CLOSE, ADDRESS 2053 ........................................... 19 SELECT ALARM OUTPUT FOR KEYFOB CHIRP, ADDRESS 1423............... 19 SELECT DEGREES CELSIUS, ADDRESS 1668 ................................................ 28 SELECTIVE BYPASS (ZONE OPTION), ADDRESS 0904, 0968 ...................... 29 SENSOR WATCH (ZONE OPTION), ADDRESS 0950, 1014 ............................ 29 SENSOR WATCH TIME, ADDRESS 2050 ........................................................... 15 SENSOR WATCH ZONES ........................................................................................ 7 SIA (CS RECEIVER 1 FORMAT)............................................................................ 20 SILENT KNIGHT FAST (CS RECEIVER 1 FORMAT) ......................................... 20 SINGLE DIGIT ONLY, ADDRESS 0461 ................................................................ 20 SINGLE DIGIT ONLY, ADDRESS 0483 ................................................................ 20 SINGLE DIGIT ONLY, ADDRESS 0505 ................................................................ 20 SOUND ALARM ON EXIT ERROR, ADDRESS 2053 ......................................... 19 STATUS REPORT, ADDRESS 1420 ..................................................................... 19 SUM CHECK, ADDRESS 0461............................................................................... 20 SUM CHECK, ADDRESS 0483............................................................................... 20 SUM CHECK, ADDRESS 0505............................................................................... 20 SUPPRESS BYPASS REMINDER WHEN ARMED, ADDRESS 1421 ............. 19 NAPCO Security Systems R SWINGER SHUTDOWN (ZONE OPTION), ADDRESS 0918, 0982 .................29 SYSTEM DELAYS & TIMEOUTS (ADDRESS 0000-0002, 1413, 1417, 2050 & 2055)............................................................................................................................15 SYSTEM DELAYS & TIMEOUTS (ADDRESS 1418-1419).................................15 SYSTEM OPTIONS (ADDRESS 0836-0863 & 2045) ..........................................17 SYSTEM OPTIONS (ADDRESS 1420-1424, 2051-2054) ...................................19 SYSTEM OUTPUT TIMEOUTS (ADDRESS 1412 & 1414-1416) ......................16 SYSTEM PROGRAMMING OPTIONS .................................................................... 4 SYSTEM RESPONSE ACTIVATED BY AREA 1 EVENT/TROUBLE ...............17 SYSTEM RESPONSE ACTIVATED BY GLOBAL EVENT/TROUBLE, ............17 TAMPER, ADDRESS 0702 ......................................................................................22 TCP/IP PANEL/SITE INITIATED FUNCTIONS, ADDRESS 2054 .............. 19 TELCO FAIL, ADDRESS 0683 ................................................................................22 TEMPERATURE DISPLAY AT KEYPAD (ADDRESS 1666-1668) ....................28 TEMPERATURE LOWER LIMIT, ADDRESS 1666..............................................28 TEMPERATURE OPTIONS, ADDRESS 1668......................................................28 TEMPERATURE UPPER LIMIT, ADDRESS 1667...............................................28 TEST TIMER ..............................................................................................................10 TEST TIMER, ADDRESS 0682 ...............................................................................22 TIME ............................................................................................................................10 TOTAL NUMBER OF ZONES IN AREA 1 ............................................................... 6 TOUCH-TONE DIALING ONLY, ADDRESS 0788 ...............................................22 TOUCH-TONE DIALING W/ROTARY BACKUP, ADDRESS 0788 ...................22 TRANSMITTER WIRELESS POINTS ENROLLING ........................................................................................................... 9 TROUBLE ON OPEN (ZONE OPTION), ADDRESS 0934, 0998.......................29 TROUBLE ON SHORT (ZONE OPTION), ADDRESS 0935, 0999 ....................29 TROUBLE RESTORE 1 (ZONE OPTION), ADDRESS 0928, 0992 ..................29 TROUBLE RESTORE 3 (ZONE OPTION), ADDRESS 0932, 0996 ..................29 TROUBLE RESTORE, ADDRESS 0672 ...............................................................22 TROUBLE TELCO 1 (ZONE OPTION), ADDRESS 0927, 0991 ........................29 TROUBLE TELCO 3 (ZONE OPTION), ADDRESS 0931, 0995 ........................29 TROUBLE, ADDRESS 0671 ....................................................................................22 UNIVERSAL HIGH SPEED (CS RECEIVER 1 FORMAT) ..................................20 USER CODES ...........................................................................................................38 USER PROGRAM AREA OPTION ....................................................................................................... 9 USER PROGRAM MODE .......................................................................................... 4 USER PROGRAM MODE ACCESSING.........................................................................................................38 PRELIMINARY INFORMATION ........................................................................37 USERS TO REPORT OPENING AND CLOSINGS .............................................24 VERI-PHONE AUDIO PRIORITY OVER ALARMS, ADDRESS 1424...............19 VERI-PHONE ZONES TRIP PGM2 OUTPUT, ADDRESS 1424 .......................19 WIRELESS TROUBLE ACTIVATES TELCO 1, ADDRESS 1423......................19 WIRELESS TROUBLE ACTIVATES TELCO 3, ADDRESS 1423......................19 WIRING DIAGRAM ...................................................................................................56 XMITTER LOW BATTERY, ADDRESS 0673........................................................22 XMITTER SUPERVISION, ADDRESS 0674 .........................................................22 GEM-P816 Programming Instructions Page 50 ALPHABETICAL INDEX (CONT'D) XMITTER TAMPER, ADDRESS 0675 ................................................................... 22 ZONE 6 TEMPERATURE SENSOR ...................................................................... 28 ZONE ANDING GROUP 1 (ZONE OPTION), ADDRESS 0946, 1010 .............. 29 ZONE ANDING GROUP 2 (ZONE OPTION), ADDRESS 0947, 1011 .............. 29 ZONE ANDING GROUP 3 (ZONE OPTION), ADDRESS 0948, 1012 .............. 29 ZONE ANDING GROUP 4 (ZONE OPTION), ADDRESS 0949, 1013 .............. 29 ZONE AREA 1 (ZONE OPTION), ADDRESS 0936, 1000 .................................. 29 ZONE DESCRIPTIONS ENTERING ........................................................................................................... 10 ZONE DESCRIPTIONS............................................................................................ 39 ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-1016)............................. 29 ZONE REPORT CODE OPTIONS ......................................................................... 23 ZONE RESPONSE ................................................................................................... 41 NAPCO Security Systems GEM-P816 Programming Instructions R Page 51 ADDRESS NUMBER INDEX ADDRESS 0000 .................................................. EXIT DELAY ................................................................................................................... 15 ADDRESS 0000-0002 ......................................... SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 0001 .................................................. ENTRY DELAY 1 ............................................................................................................ 15 ADDRESS 0002 .................................................. ENTRY DELAY 2 ............................................................................................................ 15 ADDRESS 0460 .................................................. CS RECEIVER 1 FORMAT ............................................................................................. 20 ADDRESS 0461 .................................................. 1400HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0461 .................................................. 2300HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0461 .................................................. 3/1 WITH EXTENDED RESTORES ................................................................................ 20 ADDRESS 0461 .................................................. CS RECEIVER OPTIONS - TELCO 1 ............................................................................. 20 ADDRESS 0461 .................................................. ENABLE ZONE NUMBER ON PULSE ALARM ............................................................... 20 ADDRESS 0461 .................................................. SINGLE DIGIT ONLY ...................................................................................................... 20 ADDRESS 0461 .................................................. SUM CHECK................................................................................................................... 20 ADDRESS 0461 .................................................. ENABLE TCP/IP AES RPT ............................................................................................. 20 ADDRESS 0462-0481 ......................................... CS RECEIVER 1 TELEPHONE NUMBER ...................................................................... 20 ADDRESS 0482 .................................................. CS RECEIVER 2 FORMAT ............................................................................................. 20 ADDRESS 0483 .................................................. 1400HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0483 .................................................. 2300HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0483 .................................................. 3/1 WITH EXTENDED RESTORES ................................................................................ 20 ADDRESS 0483 .................................................. CS RECEIVER OPTIONS - TELCO 2 ............................................................................. 20 ADDRESS 0483 .................................................. ENABLE ZONE NUMBER ON PULSE ALARM ............................................................... 20 ADDRESS 0483 .................................................. SINGLE DIGIT ONLY ...................................................................................................... 20 ADDRESS 0483 .................................................. SUM CHECK................................................................................................................... 20 ADDRESS 0483 .................................................. ENABLE TCP/IP AES RPT ............................................................................................. 20 ADDRESS 0484-0503 ......................................... CS RECEIVER 2 TELEPHONE NUMBER ...................................................................... 20 ADDRESS 0504 .................................................. CS RECEIVER 3 FORMAT ............................................................................................. 20 ADDRESS 0505 .................................................. 1400HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0505 .................................................. 2300HZ HANDSHAKE/KISSOFF .................................................................................... 20 ADDRESS 0505 .................................................. 3/1 WITH EXTENDED RESTORES ................................................................................ 20 ADDRESS 0505 .................................................. CS RECEIVER OPTIONS - TELCO 3 ............................................................................. 20 ADDRESS 0505 .................................................. ENABLE ZONE NUMBER ON PULSE ALARM ............................................................... 20 ADDRESS 0505 .................................................. SINGLE DIGIT ONLY ...................................................................................................... 20 ADDRESS 0505 .................................................. SUM CHECK................................................................................................................... 20 ADDRESS 0505 .................................................. ENABLE TCP/IP AES RPT ............................................................................................. 20 ADDRESS 0506-0525 ......................................... CS RECEIVER 3 TELEPHONE NUMBER ...................................................................... 20 ADDRESS 0526-0545 ......................................... DOWNLOAD/CALLBACK OPTIONS ............................................................................... 16 ADDRESS 0546 .................................................. LEADING DIGITS FOR PAGER FORMAT (1ST DIGIT) .................................................. 16 ADDRESS 0546 .................................................. PAGER FORMAT OPTIONS ........................................................................................... 16 ADDRESS 0547 .................................................. LEADING DIGITS FOR PAGER FORMAT (2ND DIGIT) ................................................. 16 ADDRESS 0547 .................................................. PAGER FORMAT OPTIONS ........................................................................................... 16 ADDRESS 0560-0667 ......................................... CS SUBSCRIBER ID OPTIONS ...................................................................................... 21 ADDRESS 0670 .................................................. ALARM RESTORE.......................................................................................................... 22 ADDRESS 0671 .................................................. TROUBLE ....................................................................................................................... 22 ADDRESS 0672 .................................................. TROUBLE RESTORE ..................................................................................................... 22 ADDRESS 0673 .................................................. XMITTER LOW BATTERY .............................................................................................. 22 NAPCO Security Systems R GEM-P816 Programming Instructions Page 52 ADDRESS NUMBER INDEX (CONT'D) ADDRESS 0674 .................................................. XMITTER SUPERVISION ............................................................................................... 22 ADDRESS 0675 .................................................. XMITTER TAMPER ......................................................................................................... 22 ADDRESS 0677 .................................................. OPENING ....................................................................................................................... 22 ADDRESS 0678 .................................................. CLOSING ........................................................................................................................ 22 ADDRESS 0679 .................................................. OPENING AFTER ALARM .............................................................................................. 22 ADDRESS 0680 .................................................. CONDITIONAL CLOSE ................................................................................................... 22 ADDRESS 0681 .................................................. CANCEL ......................................................................................................................... 22 ADDRESS 0682 .................................................. TEST TIMER ................................................................................................................... 22 ADDRESS 0683 .................................................. TELCO FAIL.................................................................................................................... 22 ADDRESS 0683-0708 ......................................... CS SYSTEM REPORTING CODES ................................................................................ 22 ADDRESS 0684 .................................................. RF REC. TROUBLE ........................................................................................................ 22 ADDRESS 0685 .................................................. MEMORY FAIL ............................................................................................................... 22 ADDRESS 0686 .................................................. LOW BATTERY .............................................................................................................. 22 ADDRESS 0687 .................................................. PANEL AC FAIL .............................................................................................................. 22 ADDRESS 0688 .................................................. EZM TAMPER................................................................................................................. 22 ADDRESS 0689 .................................................. ALARM OUTPUT SUPERV. ............................................................................................ 22 ADDRESS 0698 .................................................. AMBUSH ......................................................................................................................... 22 ADDRESS 0699 .................................................. PANIC ............................................................................................................................. 22 ADDRESS 0700 .................................................. FIRE ................................................................................................................................ 22 ADDRESS 0701 .................................................. AUXILIARY ..................................................................................................................... 22 ADDRESS 0702 .................................................. TAMPER ......................................................................................................................... 22 ADDRESS 0703 .................................................. FAIL TO OPEN ............................................................................................................... 22 ADDRESS 0704 .................................................. FAIL TO CLOSE ............................................................................................................. 22 ADDRESS 0705 .................................................. KEYFOB LOW BATTERY ............................................................................................... 22 ADDRESS 0720-0735 ......................................... CS ZONE REPORTING OPTIONS ................................................................................. 23 ADDRESS 0785 .................................................. CS AREA & SYSTEM REPORTING OPTIONS ............................................................... 22 ADDRESS 0785 .................................................. DISABLE OPENING REPORTS ...................................................................................... 22 ADDRESS 0786 .................................................. CS AREA & SYSTEM REPORTING OPTIONS ............................................................... 22 ADDRESS 0786 .................................................. DISABLE CLOSING REPORTS ...................................................................................... 22 ADDRESS 0788 .................................................. BACKUP REPORT ON TELCO 1 & 2 ............................................................................. 22 ADDRESS 0788 .................................................. CANCEL NEXT TEST TIMER ON ANY REPORT ........................................................... 22 ADDRESS 0788 .................................................. CS AREA & SYSTEM REPORTING OPTIONS ............................................................... 22 ADDRESS 0788 .................................................. CS SYSTEM REPORT OPTIONS ................................................................................... 22 ADDRESS 0788 .................................................. DISABLE AUTO DIAL TONE DETECT............................................................................ 22 ADDRESS 0788 .................................................. DISABLE WAIT FOR HANDSHAKE ON TRANSMIT ....................................................... 22 ADDRESS 0788 .................................................. DISABLE WAIT FOR SILENCE (PAGER FORMAT) ....................................................... 22 ADDRESS 0788 .................................................. TOUCH-TONE DIALING ONLY....................................................................................... 22 ADDRESS 0788 .................................................. TOUCH-TONE DIALING W/ROTARY BACKUP .............................................................. 22 ADDRESS 0800-0831 ......................................... CS USER REPORTING OPTIONS ................................................................................. 24 ADDRESS 0836 .................................................. ALARM OUTPUT ............................................................................................................ 17 ADDRESS 0836-0863 ......................................... SYSTEM OPTIONS ........................................................................................................ 17 ADDRESS 0837 .................................................. PULSED ALARM OUTPUT ............................................................................................. 17 ADDRESS 0838 .................................................. PGM1 OUTPUT .............................................................................................................. 17 ADDRESS 0839 .................................................. PGM2 OUTPUT .............................................................................................................. 17 NAPCO Security Systems GEM-P816 Programming Instructions R Page 53 ADDRESS NUMBER INDEX (CONT'D) ADDRESS 0840 .................................................. REPORT EVENT TELCO 1 ............................................................................................. 17 ADDRESS 0841 .................................................. REPORT RESTORE TELCO 1 ....................................................................................... 17 ADDRESS 0842 .................................................. REPORT EVENT TELCO 3 ............................................................................................. 17 ADDRESS 0843 .................................................. REPORT RESTORE TELCO 3 ....................................................................................... 17 ADDRESS 0856 .................................................. PULSED ALARM OUTPUT ............................................................................................. 17 ADDRESS 0857 .................................................. ALARM OUTPUT ............................................................................................................ 17 ADDRESS 0858 .................................................. PGM1 OUTPUT .............................................................................................................. 17 ADDRESS 0860 .................................................. PGM2 OUTPUT .............................................................................................................. 17 ADDRESS 0861 .................................................. REPORT EVENT TELCO 1 ............................................................................................. 17 ADDRESS 0863 .................................................. REPORT EVENT TELCO 3 ............................................................................................. 17 ADDRESS 0900-1016 ......................................... ZONE OPTIONS - ZONES 1 TO 16 ................................................................................ 29 ADDRESS 1412 .................................................. PGM2 OUTPUT TIMEOUT ............................................................................................. 16 ADDRESS 1412 .................................................. SYSTEM OUTPUT TIMEOUTS....................................................................................... 16 ADDRESS 1413 .................................................. PGM2 OUTPUT ACCESS CNTRL TIMEOUT ................................................................. 15 ADDRESS 1413 .................................................. SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 1414 .................................................. ALARM OUTPUT TIMEOUT ........................................................................................... 16 ADDRESS 1414-1416 ......................................... SYSTEM OUTPUT TIMEOUTS ....................................................................................... 16 ADDRESS 1415 .................................................. PULSE ALARM OUTPUT TIMEOUT ............................................................................... 16 ADDRESS 1416 .................................................. PGM1 OUTPUT TIMEOUT ............................................................................................. 16 ADDRESS 1417 .................................................. ABORT DELAY ............................................................................................................... 15 ADDRESS 1417 .................................................. SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 1418 .................................................. CHIME TIME ................................................................................................................... 15 ADDRESS 1418-1419 ......................................... SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 1419 .................................................. AC FAIL REPORT DELAY .............................................................................................. 15 ADDRESS 1420 .................................................. CLOSING REPORT ONLY ON CONDITIONAL CLOSE.................................................. 19 ADDRESS 1420 .................................................. DISABLE ZONE FAULT SCROLLING ............................................................................. 19 ADDRESS 1420 .................................................. ENABLE AUTOARM IF NOT CLOSED AT END OF WINDOW ....................................... 19 ADDRESS 1420 .................................................. ENABLE KEYPAD TIME/DATE DISPLAY ....................................................................... 19 ADDRESS 1420 .................................................. INCL. SEL./GRP. BYPASS IN COND. CLOSE /STATUS ................................................ 19 ADDRESS 1420 .................................................. OPENING REPORT ONLY AFTER ALARM REPORT .................................................... 19 ADDRESS 1420 .................................................. STATUS REPORT .......................................................................................................... 19 ADDRESS 1420-1424 ......................................... SYSTEM OPTIONS ........................................................................................................ 19 ADDRESS 1421 .................................................. ACCESS CONTROL ON PGM2 OUTPUT ...................................................................... 19 ADDRESS 1421 .................................................. AUTO BELL TEST ON ARMING ..................................................................................... 19 ADDRESS 1421 .................................................. AUTO RESET AFTER BURGLARY OUTPUT TIMEOUT ................................................ 19 ADDRESS 1421 .................................................. DISABLE KEYPAD INSTANT MODE .............................................................................. 19 ADDRESS 1421 .................................................. ENABLE LOCAL ALARM ON FIRST ZONE AND TRIP ................................................... 19 ADDRESS 1421 .................................................. ENABLE MANAGER'S MODE......................................................................................... 19 ADDRESS 1421 .................................................. MAINTAINED KEYSWITCH ARMING ............................................................................. 19 ADDRESS 1421 .................................................. SUPPRESS BYPASS REMINDER WHEN ARMED ........................................................ 19 ADDRESS 1422 .................................................. CHANGE PULSE OUTPUT TO TEMPORAL OUTPUT ................................................... 19 ADDRESS 1422 .................................................. CHIRP OUTPUT ON KEYFOB ARM/DISARM ................................................................ 19 ADDRESS 1422 .................................................. DISABLE CALLBACK DOWNLOAD ................................................................................ 19 ADDRESS 1422 .................................................. DISABLE KEYPAD FUNCTION MODE DOWNLOAD ..................................................... 19 NAPCO Security Systems R GEM-P816 Programming Instructions Page 54 ADDRESS NUMBER INDEX (CONT'D) ADDRESS 1422 .................................................. ENABLE GLOBAL AMBUSH CODE................................................................................ 19 ADDRESS 1422 .................................................. ENABLE RESIDENTIAL FIRE ......................................................................................... 19 ADDRESS 1422 .................................................. INTERIOR NORMALLY BYPASSED ............................................................................... 19 ADDRESS 1422 .................................................. RESET DAY ZONE WITH ARM/DISARM ONLY ............................................................. 19 ADDRESS 1423 .................................................. ENABLE ALARM OUTPUT ON TELCO FAIL ONLY WHEN ARMED .............................. 19 ADDRESS 1423 .................................................. ENABLE LINE-FAULT TEST ........................................................................................... 19 ADDRESS 1423 .................................................. INHIBIT SYSTEM TROUBLE AUDIBLE AT KEYPAD ..................................................... 19 ADDRESS 1423 .................................................. LINE-FAULT TEST ONLY WHEN ARMED ...................................................................... 19 ADDRESS 1423 .................................................. SELECT ALARM OUTPUT FOR KEYFOB CHIRP .......................................................... 19 ADDRESS 1423 .................................................. WIRELESS TROUBLE ACTIVATES TELCO 1 ................................................................ 19 ADDRESS 1423 .................................................. WIRELESS TROUBLE ACTIVATES TELCO 3 ................................................................ 19 ADDRESS 1424 .................................................. AUTOMATIC INTERIOR BYPASS/EASY EXIT ............................................................... 19 ADDRESS 1424 .................................................. DISABLE 2ND CALL ANS. MACHINE OVERRIDE ......................................................... 19 ADDRESS 1424 .................................................. DISABLE CODE REQUIRED FOR EZ BYPASS ............................................................. 19 ADDRESS 1424 .................................................. DON'T CLEAR PGM2 OUTPUT WITH DISARM ............................................................. 19 ADDRESS 1424 .................................................. RESOUND ON WIRELESS SMOKE LOW BATTERY ..................................................... 19 ADDRESS 1424 .................................................. VERI-PHONE AUDIO PRIORITY OVER ALARMS .......................................................... 19 ADDRESS 1424 .................................................. VERI-PHONE ZONES TRIP PGM2 OUTPUT ................................................................. 19 ADDRESS 1425-1431 ......................................... ENABLE KEYPAD TYPE & ACTIVATION ....................................................................... 27 ADDRESS 1425-1431 ......................................... KEYPAD OPTIONS ......................................................................................................... 27 ADDRESS 1440-1446 ......................................... ENABLE KEYPAD OPTIONS .......................................................................................... 27 ADDRESS 1440-1446 ......................................... KEYPAD OPTIONS ......................................................................................................... 27 ADDRESS 1455-1456 ......................................... EZM GROUP OPTIONS.................................................................................................. 25 ADDRESS 1473 .................................................. BURGLARY OUTPUT TURNS OFF UPON DISARM ...................................................... 26 ADDRESS 1473-1485 ......................................... AREA BELL CONTROL OPTIONS.................................................................................. 26 ADDRESS 1477 .................................................. PULSED BURG OUTPUT TURNS OFF UPON DISARM ................................................ 26 ADDRESS 1481 .................................................. PGM1 OUTPUT TURNS OFF UPON DISARM ............................................................... 26 ADDRESS 1485 .................................................. PGM2 OUTPUT TURNS OFF UPON DISARM ............................................................... 26 ADDRESS 1666 .................................................. TEMPERATURE LOWER LIMIT ..................................................................................... 28 ADDRESS 1666-1668 ......................................... TEMPERATURE DISPLAY AT KEYPAD......................................................................... 28 ADDRESS 1667 .................................................. TEMPERATURE UPPER LIMIT ...................................................................................... 28 ADDRESS 1668 .................................................. ENABLE TEMPERATURE DISPLAY OPTION ................................................................ 28 ADDRESS 1668 .................................................. REPORT TEMPERATURE ALARM (ZONE 6) ................................................................ 28 ADDRESS 1668 .................................................. SELECT DEGREES CELSIUS ........................................................................................ 28 ADDRESS 1668 .................................................. TEMPERATURE OPTIONS ............................................................................................ 28 ADDRESS 2029-2044 ......................................... RF RECEIVER & SUPERVISORY TIMER OPTIONS ...................................................... 36 ADDRESS 2045 .................................................. GLOBAL AMBUSH CODE .............................................................................................. 17 ADDRESS 2045 .................................................. SYSTEM OPTIONS ........................................................................................................ 17 ADDRESS 2050 .................................................. SENSOR WATCH TIME.................................................................................................. 15 ADDRESS 2050 .................................................. SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 2051 .................................................. DISABLE [ON/OFF] AS EASY EXIT ................................................................................ 19 ADDRESS 2051 .................................................. DISABLE SYSTEM TROUBLE AUDIBLE TIMEOUT ....................................................... 19 ADDRESS 2051 .................................................. ENABLE "K SERIES" STYLE KEYPADS ........................................................................ 19 ADDRESS 2051 .................................................. ENABLE CANCEL REPORT TO TELCO 3 ..................................................................... 19 NAPCO Security Systems GEM-P816 Programming Instructions R Page 55 ADDRESS NUMBER INDEX (CONT'D) ADDRESS 2051 .................................................. ENABLE GEM-PRINT MODULE ..................................................................................... 19 ADDRESS 2051 .................................................. ENABLE KEYPAD SET TIME/DATE MESSAGE ............................................................. 19 ADDRESS 2051-2054 ......................................... SYSTEM OPTIONS ........................................................................................................ 19 ADDRESS 2052 .................................................. LUG E15 AREA 1 ARMED AWAY ONLY ........................................................................ 19 ADDRESS 2052 .................................................. PGM ON RF TRANSMITTER TAMPER .......................................................................... 19 ADDRESS 2053 .................................................. DIGITAL DIALER RPT ENTER /EXIT TEST MODE ........................................................ 19 ADDRESS 2053 .................................................. DISABLE CALL WAITING ON 1ST ATTEMPT ................................................................ 19 ADDRESS 2053 .................................................. ENABLE CP-01 EGRESS TONES ONLY........................................................................ 19 ADDRESS 2053 .................................................. ENABLE CP-01 LIMITS................................................................................................... 19 ADDRESS 2053 .................................................. ENABLE KEYPAD 1 ONLY PROGRAMMING ................................................................. 19 ADDRESS 2053 .................................................. EXIT TIME RESTART ..................................................................................................... 19 ADDRESS 2053 .................................................. RPT EXIT ERR/RECENT CLOSE ................................................................................... 19 ADDRESS 2053 .................................................. SOUND ALARM ON EXIT ERROR ................................................................................. 19 ADDRESS 2054 .................................................. ENABLE TCP/IP COMMUNICATIONS ............................................................................ 19 ADDRESS 2054 .................................................. TCP/IP PANEL/SITE INITIATED FUNCTIONS ................................................................ 19 ADDRESS 2055 .................................................. REPORT CANCEL WINDOW ......................................................................................... 15 ADDRESS 2055 .................................................. SYSTEM DELAYS & TIMEOUTS .................................................................................... 15 ADDRESS 2056 .................................................. RF RECEIVER & SUPERVISORY TIMER OPTIONS ...................................................... 36 ADDRESS 2059 .................................................. DOWNLOAD/CALLBACK OPTIONS ............................................................................... 16 ADDRESS 2059 .................................................. NO. RINGS BEFORE PICKUP ........................................................................................ 16 ADDRESS 2059 .................................................. NUMBER OF RINGS BEFORE PICKUP ......................................................................... 16 ADDRESS 2285 .................................................. CLEAR DEALER PROGRAM .......................................................................................... 37 ADDRESS 2285 .................................................. ERASE DEALER PROGRAM.......................................................................................... 37 ADDRESS 2286 .................................................. COLD START ................................................................................................................. 37 ADDRESS 2286 .................................................. ERASE ENTIRE PROGRAM ........................................................................................... 37 NAPCO Security Systems R GEM-P816 Programming Instructions Page 56 GEM-P816 WIRING DIAGRAM Smoke Detector Compatibility Identifier GEM-P816 NAPCO Security Systems GEM-P816 Programming Instructions R