K21 Engine type KDW2204 Alternator type ECP 28 1L/4 GENERAL CHARACTERISTICS DESCRIPTIVE Frequency (Hz) 50 Reference voltage (V) 400/230 Max power ESP (kVA) 21 Max power ESP (kWe) 16.8 Max power PRP (kVA) 19.1 Max power PRP (kWe) 15.3 Intensity (A) 30 Standard Control Panel NEXYS Optional control panel TELYS DIMENSIONS COMPACT VERSION Mechanic governor Length (mm) 1410 Mechanically welded chassis with antivibration Width (mm) 720 Main line circuit breaker Height (mm) 1020 Radiator for wiring temperature of 48/50°C max with Tank capacity (L) 50 Protective grille for fan and rotating parts Dry weight (kg) 480 9 dB(A) silencer supplied separately Length (mm) 1797 Charger DC starting battery with electrolyte Width (mm) 775 12 V charge alternator and starter Height (mm) 1311 Delivered with oil and coolant -30°C Tank capacity (L) 93 Manual for use and installation Dry weight (kg) 528 DIMENSIONS SOUNDPROOFED VERSION POWER DEFINITION PRP : Prime Power is available for an unlimited number of annual operating hours in variable load applications, in accordance with ISO 8528-1. ESP : The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8528-1. Overload is not allowed TERMS OF USE According to the standard, the nominal power assigned by the genset is given for 25°C Air Intlet Temperature, of a barometric pressure of 100 kPA (100 m A.S.L), and 30 % relative humidity. For particular conditions in your installation, refer to the derating table. ASSOCIATED UNCERTAINLY For the generating sets used indoor, where the acoustic pressure levels depends on the installation conditions, it is not possible to specify the ambient noise level in the exploitation and maintenance instructions . You will also find in our exploitation and maintenance instructions a warning concerning the air noise dangers and the need to implement appropriated preventive measures. Canopy M126 Length (mm) 1750 Width (mm) 775 Height (mm) 1230 Tank capacity (L) 50 Dry weight (kg) 650 Acoustic pressure level @1m in dB(A) 76 (associated uncertainty (K)) .7 Canopy M126 DW Length (mm) 1797 Width (mm) 775 Height (mm) 1391 Tank capacity (L) 93 Dry weight (kg) 790 Acoustic pressure level @1m in dB(A) 76 (associated uncertainty (K)) .7 POWERS TABLE Voltage (V) ESP kWe PRP kVA kWe kVA Standby Amps 17/10/2012 This document is not contractual - The SDMO Industries company reserves the right to modify any of the characteristics stated in this catalogue without prior notice, in a constant effort to improve the quality of its products. K21 Voltage (V) 415/240 400/230 380/220 240 TRI 230 TRI 220 TRI 220/127 kWe ESP kVA kWe PRP kVA Standby Amps 17 17 17 17 17 17 16 21 21 21 21 21 21 20 15 15 15 15 15 15 14 19 19 19 19 19 19 18 29 30 32 51 53 55 52 17/10/2012 This document is not contractual - The SDMO Industries company reserves the right to modify any of the characteristics stated in this catalogue without prior notice, in a constant effort to improve the quality of its products. K21 ENGINE SPECIFICATIONS GENERAL ENGINE DATAS Description Engine model Cylinder arrangement Number of cylinders Bore (mm) Stroke (mm) Displacement (C.I.) Compression ratio Speed (RPM) Pistons speed (m/s) Maximum stand-by power at rated RPM Governor type Frequency regulation (%) BMEP (bar) EXHAUST KDW2204 KOHLER L Exhaust gas flow (L/s) Exhaust gas temperature (°C) Max. exhaust back pressure (mm EC) 26 460 515 4 88 90.4 2.2 22,5 : 1 1500 4.52 FUEL Consumption @ 100% load (L/h) Consumption @ 75% load (L/h) Consumption @ 50% load (L/h) Maximum fuel pump flow (L/h) 6.15 4.6 3.25 65 19.5 Mechanical +/- 2.5% 6.44 OIL Min. oil pressure (bar) Max. oil pressure (bar) Carter oil capacity (L) 1.5 10 5.7 COOLING SYSTEM Radiator & Engine capacity (L) Max water temperature (°C) Type of coolant Thermostat (°C) 7 110 Gencool 80 AIR INTAKE Intake air flow (L/s) Max. intake restriction (mm EC) 25 200 17/10/2012 This document is not contractual - The SDMO Industries company reserves the right to modify any of the characteristics stated in this catalogue without prior notice, in a constant effort to improve the quality of its products. K21 ALTERNATOR SPECIFICATIONS GENERAL DATAS Description Alternator brand Number of phase Altitude (m) Overspeed (rpm) Number of pole Excitation system Insulation class Regulation Number of bearing Coupling Air flow (m3/s) REACTANCES (R) - TIME CONSTANT(CT) ECP 28 1L/4 MECC ALTE 3 0 à 1000 0 4 AVR H DSR 1 Direct .088 POWERS Power factor (Cos Phi) Continuous Nominal Rating 40°C (kVA) Standby Nominal Rating 40°C (kVA) Standby Rating 27°C (kVA) Efficiencies 4/4 load (%) Short circuit ratio (Kcc) Direct axis synchro reactance Quadra axis synchro reactance Open circuit time constant (T'do) (ms) Direct axis transcient reactance Short circuit transcient time constant Direct axis subtranscient reactance Subtranscient time constant (T"d) (ms) Quadra axis subtranscient reactance Zero sequence reactance unsaturated Negative sequence reactance saturated Armature time constant (Ta) (ms) .62 180 78 850 16.8 44 9.6 14 22 3.3 14.4 12 OTHER DATAS .8 20 20.5 21.5 87.4 No load excitation current (io) (A) Full load excitation current (ic) (A) Full load excitation voltage (uc) (V) Engine start (Delta U = 20% perm. or Transcient dip (4/4 load) - PF : 0,8 AR No load losses (W) Heat rejection (W) .5 1.5 0 0 0 0 2307 DIMENSIONS AND NOISE LEVELS DIMENSIONS AND NOISE LEVELS 17/10/2012 This document is not contractual - The SDMO Industries company reserves the right to modify any of the characteristics stated in this catalogue without prior notice, in a constant effort to improve the quality of its products. K21 CONTROL PANELS NEXYS, comprehensive and simple TELYS, ergonomic and user-friendly The NEXYS is a versatile control unit allowing operation in manual or automatic mode. Equipped with an LCD screen, the user-friendly NEXYS offers high-quality basic functions to guarantee simple, reliable operation of your generating set. The highly versatile TELYS control unit is complex yet accessible, thanks to the particular attention paid to optimising its ergonomics and ease of use. With its large display screen, buttons and scroll wheel, it places the accent on simplicity and communication. Offers the following functions: The TELYS offers the following functions: Standard electrical measurements: voltmeter, frequency meter, ammeter. Electrical measurements: voltmeter, frequency meter, ammeter. Engine parameters: working hours counter, engine speed, battery voltage, fuel level. Engine parameters: working hours counter, oil pressure, coolant temperature, fuel level, engine speed, battery voltage. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed (> 60 kVA), charging alternator fault, low fuel level, emergency stop. For more information, please refer to the sales documentation. Alarms and faults: oil pressure, coolant temperature, failure to start, overspeed, alternator min./max., battery voltage min./max., emergency stop, fuel level. Ergonomics: wheel for navigating around the various menus. Communication: remote control and operation software, USB connections, PC connection. For more information on the product and its options, please refer to the sales documentation. 17/10/2012 This document is not contractual - The SDMO Industries company reserves the right to modify any of the characteristics stated in this catalogue without prior notice, in a constant effort to improve the quality of its products.