Preview only show first 10 pages with watermark. For full document please download

General Line Catalogue

   EMBED


Share

Transcript

Communication Systems GENERAL LINE CATALOGUE 2016 C o n COLOR VIDEO ENTRY SECURITY DOOR ROOM 4 8 DOOR ROOM 1 2 DOOR ROOM 1 2 DOOR 7-inch Touchscreen Color Video Intercom JP-4MED Wide and Zoom & PanTilt Hands-free Color Video Intercom MASTER PC IP color video Intercom adaptor Max.20 ROOM 2 3 MASTER DOOR 12 IX SYSTEM Security IP Video Intercom System IS SYSTEM JF-2MED 13 DOOR Hands-free Color Video Intercom 15 ROOM 1 5 1 4 DOOR Hands-free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt features GT SYSTEM ENTRANCE TENANT 17~33 17 System outline ENTRANCE TENANT 5 48 Standard System Configuration 19 ENTRANCE TENANT 16 500 Expanded System Configuration Entrance station Tenant station Video door station, Door station Security guard station, Control units Expanded control units, Power supply, Option GT Lift control adaptor Cabling (standard) Wiring (standard) Compatibility with the existing system Example 2 DOOR ENTRANCE MASTER SERVICE SIDE STATION 3 ROOM TENANT SUB PUBLIC SIDE ROOM 1 1 MULTI-TENANT BUILDING ENTRY SECURITY 20 21 25 27 28 29 30 31 32 33 s 35 47 59 AUDIO ENTRY SECURITY ENTRANCE TENANT 8 120 AX Integratable Audio & Video Security 8 120 AX DOOR Hands-free Color Video Intercom, Picture Memory t IP Network Audio-Video Intercom System MASTER 9 n INTEGRATED SECURITY & COMMUNICATION SYSTEM 7 JO-1MD JK-1MED e 3 7-inch Screen Color Video Intercom 1 1 10 JKW-IP DOOR t 1 4 DOOR ROOM DOOR ROOM DOOR ROOM DOOR ROOM 1 1 1 3 2 3 2 6 Hands-free Two-Wire Electric Lock Door Phone DB-1MD Hands-free Two-Wire Electric Lock Door Phone DA-4DS with DB-1MD Two-Wire Electric Lock Door Phone DA-1AS Two-Wire Electric Lock Door Phone DA-4DS Chime Tone Intercom C-123L/A Chime Tone Intercom IE-1GD(U) Chime Tone Intercom IE-2A2DU Chime Tone Intercom 64 65 67 68 69 71 72 IE-8MD 73 Audio Door Stations and Accessories 74 INTERCOM SYSTEM DOOR ROOM DOOR ROOM MASTER SUB 4 8 1 1 1 3 STATION JP-4MED Open Voice Intercom LEM-1DL Open Voice Intercom LEM Open Voice Intercom 11 DOOR 7-inch Touchscreen Color Video Intercom LEF ROOM 3 8 MASTER SUB MASTER SUB 1 4 1 3 STATION Open Voice Intercom 84 DB-1MD Handset Intercom AT-406 Handset Intercom 25 TD-H/B SERVICE SIDE PUBLIC SIDE 1 1 81 LE Sub stations & Accessories YAZ-90-3W STATION 80 83 Hands-free Intercom Security Window Intercom 85 86 87 89 / Sub Intercom 2 100 Master TC-M 91 SUB DOOR ROOM 10 1 STATION 60 Master / Sub Intercom TC-M & TB-AD10 Market-Com MC-60/4A 94 AUDIO ENTRY SECURITY AC-10S, AC-10F 95 Angle + Surface Mount Boxes 97 Accessories Accessories IER-2, EL-12S, RY-PA, RY-AC/A Power Supplies AIPHONE Approved product wire INTEGRATED SECURITY & COMMUNICATION SYSTEM 93 ACCESSORIES Access Control MULTI-TENANT BUILDING ENTRY SECURITY 85 IMU-100 MASTER COLOR VIDEO ENTRY SECURITY 79 LEF-C Handset Intercom 90 77 98 99 100 COMMUNICATION DISTANCE & INDEX Communication Distance Compatibility of video intercom system INDEX 101 102 103 INTERCOM SYSTEM ACCESSORIES Communication Systems for business, home and industry Established In 1948 Aiphone has become the most respected and reliable brand of communication systems in the world. With headquarters in Nagoya and manufacturing in Toyota City, Central Japan, we export to over 60 countries. We expand ourselves along with a North American marketing, sales and distribution center near Seattle, Washington, and an European sales and distribution center in Lisses-Evry, France. Systems For Every Application Aiphone products range from simple do-it-yourself door answering units to sophisticated video entry security systems, complex microprocessor-based commercial systems, and luxury condo/apartment security/communication systems. They are unrivaled in design simplicity, technical excellence and reliability. With over 30 standard systems, and additional manufacturing by special order, we can create a system for virtually any intercom application. Designed To Last Every Aiphone system is the result of painstaking attention to detail: contemporary European style design, the finest quality hardware and circuitry, engineered, built and 100% pre-tested for sustained trouble-free service. AIPHONE CO., LTD. in Japan Headquarters Toyota factory ISO 9001 Aiphone is the first intercom manufacturer worldwide to receive ISO 9001 certification, and the only one selling in North America, An agency representing the International Standards Organization (ISO), headquartered in Geneva, Switzerland, graded Aiphone against guidelines for design and development, production, and product inspection and testing. ISO 9001 standards provide an immediate recognition of product quality almost anywhere in the world. ISO 9001 Certified JQA-0291 AIPHONE CO., LTD. Winner Of The Deming Prize Aiphone is the first and only intercom manufacturer to win the Deming Prize, the highest international award for quality control. Named in honor of Dr. W. Edwards Deming, the award honors firms worldwide which advance and maintain manufacturing quality. Deming Prize Acquisition of ISO 14001 ISO's Environmental Standards are a series of voluntary standards and guideline reference documents which include environmental management systems, eco-labeling, environmental auditing, life cycle assessment, environmental performance evaluation, and environmental aspects in products standards. In early 1998, our management team determined to acquire ISO-14001 approval as a company-wide project, and working committee was established at the same time. Since then, with our ongoing efforts and practice about environmental management standards, we have succeeded to acquire the approval. Aiphone excludes the use of prohibited material from the product according to RoHS directive (2002/95/EC). Therefore, as of July 1, 2006, all the Aiphone products imported in EU will be fully complied with the RoHS directive. AIPHONE CORPORATION in USA AIPHONE S.A.S. in France ISO 14001 Certified JQA-EM0453 Headquarters section Toyota Factory Taiho Site AIPHONE CO., LTD. ENVIRONMENTAL REPORT We will contribute to building a sustainable society while cultivating communications with a wide spectrum of our stakeholders. Basic Environmental Philosophy Revised October 1, 2005 Based on our business philosophy of "Be Responsible for your job and don't cause of problems for others," we carry out our activities while harmonizing conservation of the global environment with our business operations. Environmental Policy The AIPHONE group aspires to be enterprises capable of making contributions to society by using communication and security technologies, conducting our environmental activities as follows: (1) We will strive to minimize environmental loads to conserve the global environment in our activities of developing, producing, selling, and servicing our products. (2) We will make our goals and objectives clear in our business activities, continuously evaluating the following items and thus improving them: a) We will aim to become a recycling society and make efforts to promote the 3R's (Reduce, Reuse, and Recycle) and minimize waste. b) We will not use harmful substances that cause environmental contamination. c) We will strive to conserve energy to prevent global warming. (3) We will conform to environment-related laws, regulations, and conventions while establishing voluntary standards to conserve the environment. (4) Placing great value on communication, we will promote the manufacture of products friendly to both humans and the environment. (5) We will conduct environmental audits in an effort to maintain and improve our environment management system. (6) We will make our environmental policy thoroughly known to our employees and all those who work together with us. (7) We will publicize this environmental policy to the general public. Certificate of acquisition of lSO 14001 accreditation This report is also posted on our website: http://www.aiphone.net Lineup Aiphone provides you with a variety of security systems and intercoms from small to extensive IP network systems, so that you can choose the perfect solution for your security needs. COLOR VIDEO ENTRY SECURITY P1~ MULTI-TENANT BUILDING ENTRY SECURITY P17~ INTEGRATED A SECURITY & COMMUNICATION SYSTEM P34~ AUDIO ENTRY SECURITY P63~ INTERCOM SYSTEM P76~ COLOR VIDEO ENTRY SECURITY 7-inch display COLOR VIDEO ENTRY SECURITY 7-inch display 1 The JP Series and JO Series intercoms feature a large 7-inch display for clear visitor identification. COLOR VIDEO ENTRY SECURITY 7inch Actual size (JO series) JP Series JO Series Touchscreen Non-mechanical touch buttons Oversized buttons and intuitive icons allow for quick navigation and control. Quick & easy icons simply require a light touch to operate the intercom. Multi-station, multi-function type Simple type Lineup 7-inch Touchscreen Color Video Intercom 7-inch Screen Color Video Intercom Wide and Zoom & PanTilt Hands-free Color Video Intercom Hands-free Color Video intercom,Picture Memory Hands-free Color Video Intercom JP-4MED JO-1MD JK-1MED JF-2MED AX 13 5 2 7-inch Touchscreen Color Video Intercom DOOR Features ROOM • • • • • 8 JP-4MED 4 7-inch touchscreen for operation Hands-free or handset audio communication Zoom/wide and pan & tilt video monitoring function Video image adjusting function Record visitor images both automatically & manually Door station Master station 2 COLOR VIDEO ENTRY SECURITY 2 Cat5e 2 2 2 JP-DV Wide and Zoom & PanTilt Vandal resistant video door station, surface mount 2 2 2 3 connectors 2 2 PT JP-4MED PS24 Hands-free color video intercom master station RY-3DL Multiple door release adaptor or GT-D Audio door station JP-DA JP-DVF* Handsfree module for JP-4MED & JP-4HD JP-DVF-L Wide and Zoom & PanTilt video door station, surface mount Wide and Zoom & PanTilt Vandal resistant video door station, flush mount JPEC Wide and Zoom & PanTilt Vandal resistant video door station, flush mount (Guidance-enabled type) JPTLIIP Power supply PS-2420  P.100 IP Interface for JP System (compatible with iOS and Android) * Marine grade option available The wide monitor clearly shows all 170 degrees of video captured by the camera The JP Series 170° wide angle and 100° vertical angle camera minimizes blind spots, ensuring a clear view of the door station area. Focus on a particular area for more detail. Zoom Using the touchscreen, zoom into visitor faces and other specific areas. Tall viewing height : Approx. 100° Touch PanTilt WIDE IMAGE ZOOM IMAGE Using the PanTilt function, view details such as ID badges or labels. Video door station Wide viewing area : Approx. 170° High image quality provides a clear view of detailed areas. Touch ZOOM IMAGE Communication network JP-DV (Master station) JP-4MED The design and specifications are subject to change without notice for improvement. 3 PANTILT IMAGE JP-4HD (Sub master station) JP-4HD x7 JP-4HD JP-4HD JP-4HD • 3 wiring methods selectable (Station-to-station, Homerun, or combined wiring) • 2 internal calls selectable (All call or Individual call) • Audio monitoring of other master stations • Option: 3 sensors connectable to the master station Commercial Residential Retail Shops Factories Schools Sub master station JP-4HD JP-4HD Cat5e Cat5e JP-4HD Cat5e PS24 JP-4HD Cat5e Hands-free color video intercom sub master station JP-4HD Boxed sets JP-4HD Cat5e JPS-4AED: JP-4MED, JP-DA, PS-2420 JPS-4AEDV: JP-4MED, JP-DV, PS-2420 JPS-4AEDF: JP-4MED, JP-DVF, PS-2420 Access Control  P.99 Lineup AC-10S JPW-BA Jx-DVF-AC Access control keypad, surface mount JP-DV + AC-10S Unit dimensions JP-DV 97 309 28.5 83.5 IER-2 5 45 135 RY-3DL 45 Video monitor Pixels Video output Night viewing 140 130 55 117 30 98 33 132 5.6 98 AC-10F 120 45 27 GT-D 100 144 150 98 68.5 125 295 AC-10S JP-DVF-L 209 30.5 8 25 Power source Power supply Consumption Calling Communication 5.6 88 29 74 JP-8Z Door release Option output Wiring 42 109 48 JP-DVF 173 129 JP-DA 145 255 Distribution adaptor  EL-12S Electric door strike  P.98 RY-3DL Multiple door release adaptor  P.6 Specifications (JP-4MED,JP-4HD) JP-4MED, JP-4HD Jx-DVF-AC JP-8Z Long distance adaptor  P.6 Jx-DVF-AC + JP-DVF PS24 COLOR VIDEO ENTRY SECURITY Cat5e JP-4HD 123 Wiring distance ( P.5) 61 24V DC PS-2420 Max. 340mA(JP-4MED). Max. 200mA (JP-4HD) Chime. Image & audio, approx. 45 or 90 sec. Automatic(Hands-free): approx. 1 min. To activate, touch TALK button. Handset: approx. 3 min. To activate, lift handset. 7-inch color LCD screen 1,150,000 pixels NTSC/PAL, 1Vp-p/75 Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: CAT5e Door to Master: 100m (1.0mm) Master to farthest sub: 300m(CAT5e) 45 Image view area (* ) For JP-DVF-L JP-DA, JP-DV, JP-DVF, JP-DVF-L (WIDE) (WIDE) (ZOOM) approx. 170˚ (ZOOM) approx. 220cm(*225) approx. 185cm(*190) approx. 130cm approx. 130cm approx. 125cm(*130) approx. 90cm(*95) approx. 60cm 150cm approx. 95cm approx. 60cm 50cm 150cm 50cm approx. 85˚ approx. 95 cm 50cm 4 7-inch Touchscreen Color Video Intercom Wiring Station-to-Station Wiring (Daisy-chain Wiring) Cumulative total wiring distance (using CAT5e cables): Max. 300m [A] [E] JP-DV JP-4MED 2 [B] JP-4HD JP-4HD JP-4HD COLOR VIDEO ENTRY SECURITY 2 A1 A2 [B] JP-4HD [C] JP-4HD JP-4HD 2 PS24 [F] Door station 1 ([A]x2)+([B]x2)+[C]=Max.300m [A] 2 PS24 [F] JP-4HD PS24 [F] M(OUT) M (IN) M(OUT) M (IN) M(OUT) M (IN) M(OUT) M (IN) 1A1 1A2 2A1 2A2 3A1 3A2 4A1 4A2 M(OUT) M (IN) M(OUT) M (IN) M(OUT) M (IN) M(OUT) Door station 2 Door station 3 Door station 4 *Same as door station 1. b1 b2 b3 b4 EL-12S S S L1 L1 EL-12S PS24 4-pin option connector Yellow Orange Door station selecting signal output Red Brown PS24 l [A], [C]: A single power supply can power up to 1 master and 2 sub master stations, or 3 sub master stations. The wiring distance varies depending on the number of powered room stations. l See “Wiring distance between each device” below for the maximum distance between each device. : CAT5e 1 E IER-2 L2 L2 12-pin option connector Black Security/Utility input specification Purple Security/Utility input 3, External talk input Input method N/O or N/C dry closure contact (start signal only detection method) Black Detection confirmation time 100 mS or more Security/Utility input 2, Yellow Contact resistance During N/O dry closure: Less than 700d Black During N/C dry closure: more than 15Kd Security/Utility input 1, Terminal short current Less than 10 mA Orange Less than 5V DC Voltage between terminals Black (when open between terminals) Option output Gray (AC/DC 24V, 1A, N/O dry closure contact) White (Unused) Blue Red Brown Video signal output S3E S3 S2E S2 S1E S1 SW SW PT VV+ (NTSC/PAL, 1Vp-p/75d) PS24 Centralized Wiring (Homerun Wiring) JP-DV etc. Cumulative total wiring distance (using CAT5e cables): Max. 300m [B]+([D]x7)=Max.300m JP-4HD JP-4HD JP-4HD JP-4HD [E] 2 [B] JP-4MED [D] 2 2 [D] [D] [D] [D] JP-4HD JP-8Z [F] (*1) 2 [G] PS24 (*2) 2 PS24 [D] 2 [D] PS24 2 JP-4HD JP-4HD (*1): The master station requires a power supply. (*2): Up to 4 sub master stations can be powered with one power supply. Use two power supplies for 5 - 7 sub master stations. See “Wiring distance between each device” on the right for the maximum distance between each device. Combined Wiring Cumulative total wiring distance (using CAT5e cables): Max. 300m [A]+([B]x2)+([D]x4)=Max.300m JP-4HD JP-DV etc. JP-4HD [E] [B] 2 JP-4MED [A] JP-4HD JP-4HD [B] JP-4HD Wiring distance between each device [D] [D] 2 2 [D] JP-8Z [F] 2 PS24 [F] 2 [G] PS24 [D] 2 5 Notes CAT5e 30m When 3 room stations are powered by a single power supply 200m 50m When 2 room stations are powered by a single power supply 50m Wire diameter (PE cable) Ø0.65 mm Ø0.8 mm Ø1.0 mm Ø1.2 mm JP-4HD H : AC transformer N : PS-2420 [A] [B] [C] [D] PS24 2 See “Wiring distance between each device” on the right for the maximum distance between each device. JP-4HD [E] [F] [G] 50m 5m 5m 100m 5m 10m 100m 10m 10m 100m 10m 10m Long distance adaptor Wiring When extending the distance between the master station and a door station Max: 600m Door to the farthest sub master station Max. 300m Cumulative total wiring distance (using CAT5e cables): Max. 300m [c] [b] JP-DV JPW-BA JP-4MED 2 [c] 2 2 PS24 [a] JPW-BA A1 A2 Long distance adaptor Features • When JP series door station is more than 100m to max. 300m away. • CCTV camera can be integrated by connecting JPW-BA. A1 A2 ON OFF B1 B2 PAL NTSC Door Station [c] Max. 15m Coaxial cable Coax CCTV camera GT-D JPW-BA 2 [c] 2 2 PS24 [a] VIDEO INPUT Coax 1 2 61 : CAT5e JP-4MED 2 VIDEO OUTPUT 109 M(OUT) PS24 [b] JPW-BA M (IN) M(OUT) 1A1 1A2 When connecting a third-party CCTV camera and an audio door station in place of a video door station. Unit dimensions 123 JP-4HD COLOR VIDEO ENTRY SECURITY 2 B1 B2 1A1 1A2 M(OUT) A1 A2 ON OFF When this switch is set to either “NTSC” or “PAL”, the Zoom / Wide and Pan & Tilt function are disabled. PS24 PAL NTSC Door Station Wiring distance between each device Specifications Wire diameter (PE cable) Ø0.65 mm Ø0.8 mm Ø1.0 mm Ø1.2 mm 5m 5m 10m 10m [a] 150m 200m 200m [b] 100m 50m 75m 100m 100m [c] Power source 24VDC, PS-2420 of system or separate Current consumption MAX. 90mA Wiring 2 parallel wires to ea. door & master. Selective door release adaptor Wiring Features Door station 1 JP-DV etc. • Selective door release with one button • Door release contacts release the door where communication is established. • Normally open contacts for electric strike. Normally closed contacts to work with magnetic locks. JP-4MED A1 A2 1A1 1A2 2A1 Used for JP-4MED RY-3DL Electric door strike 1 Unit dimensions Door release adaptor L1 L1 EL-12S RY-3DL 140 RY-3DL 74 Electric door strike 2 42 Electric door strike 3 Specifications Power source Power supply Relay contacts Wiring distance EL-12S 12~24V DC, 30mA 12~16V AC, 60mA PS-2420; PS-1820; PS-1225; AC trans. Normally open output. 1A at 50V AC. 1A at 30V DC (for other types, use matching relay) Master to RY-3DL 50m(0.65mma) 100m(1.0mma) RY-3DL to EL-12S 50m(0.65mma) 100m(1.0mma) EL-12S Electric door strike 4 EL-12S PT L1 C1 /L1 b1 b2 b3 L2 C2 /L2 L E L3 C3 /L3 H : AC transformer N : PS-2420 4-pin option connector b1 Brown b2 Red b3 Orange b4 Yellow 4 pin option connector identifies active door. b1 is brown lead, active with door 1. b2 is red lead, active with door 2. L2 L2 b3 is orange lead, active with door 3. b4 is yellow lead, active with door 4. PS24 6 7-inch Screen Color Video Intercom DOOR ROOM 2 JO-1MD 1 Door station Expansion monitor station COLOR VIDEO ENTRY SECURITY 2 4 2 JO-1FD JO-DV Vandal resistant video door station, surface mount PS18 Expansion monitor station IER-2 Call extension m P.98 or 2 PT or JO-DA JO-DVF * Video door station, surface mount Wide and Zoom & PanTilt Vandal resistant video door station, flush mount Power supply PS-1820 m P.99 Features • • • • • Total hands-free communication Video image adjusting function Room to room communication is not available Easy operation by buttons with picture indications Option output: Option button connectable to the master station and expansion monitor station. Wiring JO-DV 100m/1.0mmØ JO-1FD 100m/1.0mmØ 2 JO-1MD 4 2 PS18 7-inch screen View images more clearly with 7-inch screen! EL-12S 2 7-inch size DOOR MASTER A1 A2 A1 A2 B1 B2 CALL EXT S S The conventional size DOOR IER-2 1 E OUT DC18V Control buttons A1 A2 CALL EXT S S IER-2 1 E DC18V IN DC18V Volume control button PS18 Monitor button Option button OPTION SW SW EL-12S Screen brightness control button DOOR RELEASE L L Door release button Talk/off button The design and specifications are subject to change without notice for improvement. 7 PT Option units OPTION SW SW DOOR RELEASE L L Option units Commercial Residential Master station COLOR VIDEO ENTRY SECURITY Boxed sets 2 Standard JO-1MD Master station IER-2 Call extension m P.98 Lineup Access Control m P.95 AC-10S Access control keypad, surface mount Communication network Jx-DVF-AC Jx-DVF-AC + JO-DVF EL-12S JO-DV + AC-10S JO-1MD Power source Power supply Consumption Calling Communication M Video monitor Pixels Night viewing JO-1FD (Expansion monitor station) Unit dimensions 295 230 3.3 J0-DVF 209 130 8 JO-DV Wiring distance 21 JO-DA 129 144 AC-10S 83.5 120 88 29 25.5 33 approx. 55cm 100 132 117 5 AIPHONE approved product wire m P.100 approx. 175cm JO-DA, JO-DV, JO-DVF 98 AE7090210B AE7090210G 18V DC PS-1820 Max. 440mA(JO-1MD). Max. 460mA (JO-1FD) Chime. Image, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 2 sec. or more. 7-inch color LCD screen 1,150,000 pixels "Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 0.5A (N/O dry closure contact) Door to master (or Expansion monitor) : 2-cond., mid cap solid, non-shielded. Expansion monitor to Master : 4-cond., mid cap, solid, non-shielded. Door to Master(or Expansion monitor station): 100m (1.0mmØ) Expansion monitor to master monitor station : 100m (1.0mmØ) Monitor station to IER-2: 150m(1.0mmØ) Image view area AC-10F 36 125 IER-2 25 98 45 135 45 55 68.5 97 26.8 Door release Option output Wiring 173 Jx-DVF-AC Electric door strike m P.98 Specifications (Master station) JO-DV JO-1FD, JO-1MD JOS-1A: JO-1MD, JO-DA, PS-2420 JOS-1V: JO-1MD, JO-DV, PS-2420 JOS-1F: JO-1MD, JO-DVF, PS-2420 45 approx. 145cm approx. 50cm approx. 120cm approx. 50cm approx. 95cm 8 Wide and Zoom & PanTilt Hands-free Color Video Intercom DOOR ROOM 2 JK-1MED 1 Door station Master station Picture memory COLOR VIDEO ENTRY SECURITY 4 2 2 2 PT JK-DV Wide and Zoom & PanTilt Vandal resistant video door station, surface mount or IER-2 Call extension m P.98 PS18 JK-1MED Master station w/Wide and Zoom & PanTilt color monitor & built-in picture memory. or JK-DA JK-DVF Wide and Zoom & PanTilt video door station, surface mount Wide and Zoom & PanTilt Vandal resistant video door station, flush mount Power supply PS-1820 m P.99 Features • Total hands-free communication, auto-voice actuation • Visual monitoring with audio for 1 minute • Instant voice call-in with image • Press-to-talk operation available • Press-to-talk restriction • White LED illumination turns on in low-light conditions • Video image adjusting function • Full color video in low light situations w/o external illumination • Camera angle preset • External input • Option - Option button, press-to-talk setting, video signal output PANORAMIC WIDE View Everyone at the entrance can be identified by image from JK wide angle camera. The field of vision can be controled on Wide mode or Zoom mode from inside. WIDE IMAGE ZOOM IMAGE Zoom & PanTilt Communication network (Master station) By pressing PanTilt button, the image of the PanTilt video door station can be adjusted to a more visible position from inside on the Zoom mode. JK-1MED JK-DV M WIDE IMAGE PanTilt on Zoom mode *The screen images are simulated graphics. They are images to express functions, and are different from the real one. Please understand it beforehand. or JK-1SD JK-1HD (Sub master station) The design and specifications are subject to change without notice for improvement. 9 Lineup Sub master station JK-1SD Audio sub master station JKW-BA EL-12S JKW-IP JK-DVF-AC Long distance adaptor m P.11 *Max. 300m away from Master/sub to Door. JK-1HD Sub master station w/color monitor Electric door strike m P.98 Boxed sets IP color video intercom adaptor m P.12 Access Control m P.95 Vandal resistant color video door station with access control keypad Picture memory AC-10S AC-10F Specifications JK-DV 98 27 295 88 45 98 33 132 29 Image view area Video monitor Scanning line Video output Night viewing Door release Option output Wiring AC-10F 83.5 120 45 135 55 68.5 125 35.5 IER-2 144 25 AC-10S Power source Power supply Consumption Calling Communication 25 JK-DA 97 8 100 8 JK-DVF 209 185 80 129 JK-DVF-AC 27 29.5 173 JK-1SD 185 135 AIPHONE approved product wire m P.100 JK-DV + AC-10S Unit dimensions JK-1MED, JK-1HD AE7090210B AE7090210G JKS-1AED: JK-1MED, JK-DA, PS-2420 JKS-1AEDV: JK-1MED, JK-DV, PS-2420 JKS-1AEDF: JK-1MED, JK-DVF, PS-2420 Access control keypad, flush mount Access control keypad, surface mount COLOR VIDEO ENTRY SECURITY 4 or 117 5 Wire type Wiring distance 45 18V DC PS-1820 Max. 400mA (JK-1MED). Max. 200mA (JK-1HD). Max. 120mA (JK-1SD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3.5-inch direct-view TFT color LCD. 525 lines NTSC, 1Vp-p/75 Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1.6A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. AIPHONE approved product wire: AE7090210B, AE7090210G Master/sub to door: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma) JK-DA, JK-DV, JK-DVF (WIDE) (ZOOM) (WIDE) approx. 170˚ (ZOOM & PanTilt) approx. 225cm approx. 85cm approx. 200cm approx. 70cm approx. 105cm approx. 105cm approx. 70cm approx. 95cm 150cm approx. 90cm 50cm Zoom (up) approx. 85cm 150cm 50cm Zoom (down) approx. 75cm 50cm approx. 90cm approx. 130cm approx. 10cm Zoom (right) approx. 130cm approx. 10cm Zoom (left) 10 Wide and Zoom & PanTilt Hands-free Color Video Intercom Wiring 100m / 1.0mma JK-DV JK-1ED JK-1HD 2 COLOR VIDEO ENTRY SECURITY 4 2 JK-1SD or 4 2 IER-2 PS18 DOOR1 SUB A1 A2 B1 B2 A1 A2 SUB IN B1 B2 DOOR RELEASE L L EL-12S PT IER-2 CALL EXT 1 E S S DC18V DC18V PS18 ON OFF Press-to-talk setting switch (only JK-1MD) Option connector PS18 :PS-1820 PT :AC Transformer V+ VSW SW KS KE Brown Red Orange Yellow Green Blue External sensor input specification Video signal output (NTSC, 1Vp-p/75d) N/O or N/C dry closure contact Input method Option output (AC/DC24V,1.6A N/O dry closure contact) Detection confirmation time 100 mS or more Contact resistance During N/O dry closure: Less than 700d During N/C dry closure: more than 3Kd Less than 10 mA Terminal short current External sensor input Setting is required on JK-1MED. Cable External sensor input (start signal only detection method) Voltage between terminals Less than 20V DC (when open between terminals) Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. Long distance adaptor for JK series 200m / 1.2mma Features l When JK series color video door station is more than 100m to max. 300m away. Used for 2 JKW-BA JK-DV A1 A2 JK-1MED 100m / 1.2mma Unit dimensions 2 A1 B1 A2 B2 + – C JK-1MED A1 A2 + – Specifications Power source JKW-BA Current consumption Wiring Wire type 108.5 JKW-BA Long distance adaptor 122.5 61 Wiring distance 11 18VDC, PS-1820 of system or separate 95mA 2 parallel wires to ea. door & master. AIPHONE approved product wire: AE7120230B or 1.0mma to 1.2mma. Vinyl jacketed, PE (polyethylene) insulation cable. JK door~JKW-BA 100m~200m(1.2mma) JKW-BA~JK master/JK-1HD/JK-1SD 100m(1.2mma) JKW-BA~PS 100m(1.2mma) IP color video Intercom adaptor MASTER DOOR 1 PC 1 10 JKW-IP Max.20 Power supply PS-1820 JKW-IP IP color video intercom adaptor 2 Notice • It may not be possible to use this product with certain network environments or PCs. • To use this product via the Internet, a separate broadband connection and a router with a fixed IP address is required. • To ensure proper function only use with approved routers. Refer our homepage for a list of approved routers which allow proper operations. • Maintaining security at the computer(s) connected to the JKW-IP is the responsibility of the customer. Aiphone assumes no responsibility for any losses incurred as a result of improper PC, firewall or other security. • It is recommended that you use a 100BASE-TX wired LAN as the network. 2 2 JK systems PS18 2 m P.9 PC Application • Use of local area networks (LANs) and wide area networks (Internet) allow PCs to be used as a JK master unit • Combine up to 20 JK master/Door systems • 10 PCs can communicate to 20 JK systems • Allow a PC to function as a JK master • Connected PC(s) control PanTilt, zoom and wide views of entryway • Images or movies from entranceways can be recorded and played back at a PC • Use headset (not included) for communication • E-mail can be automatically sent to 10 e-mail addresses when called from door station • Audio recording with manual video recording • Communicate to and from JK masters • A single port can be used for multi-purpose external input Wide and Zoom & PanTilt control from PC A user friendly interface contains controls that match those on a JK-1MED. This allows the PC to be controlled in the exact manner as a master monitor. Wide and Zoom Wide and Zoom & PanTilt button PC monitor WIDE IMAGE ZOOM IMAGE PanTilt on Zoom mode Unlock the door after verifying visitor identity Video & Audio communication with entrance side by PC Unlock COLOR VIDEO ENTRY SECURITY m P.103 Features VISITOR Door Station Room to room communication with master station WIDE IMAGE PanTilt on Zoom mode (JK- 1MED or JK-1MD) Cabling 100m / 1.0mma 2 JK-DV *1 2 2 VISITOR 100m / CAT5e PS18 CAT5e 2 LAN ROUTER PC JKW-IP CAT5e PC 100m / 1.0mma *2 APPLICATION *1 Max. 20x JKW-IP LAN ROUTER CAT5e JK-1MED 5m / 1.0mma INTERNET APPLICATION *2 *2 Max. 10x PC Wiring DOOR SUB A1 A2 IN B1 B2 A1 A2 B1 B2 DOOR RELEASE L L S S IER-2 1 E DC18V PS18 PS18 :PS-1820 PT Option device input 1 S4 E Option device input 4 RY RY Option device Output *1 ~ CALL EXT LAN, Router etc. S1 E ~ EL-12S PT CAT5e LAN *1 DC18V :AC Transformer Unit dimensions *2 Option device output specifications Output method N/O dry contact Voltage between terminals AC24V 0.5A (resistive load) DC24V 0.5A (resistive load) Minimum overload : DC 100mV, 0.1mA System requirements Windows XP Home/Professional (SP3), Windows Vista Ultimate/Home/Business/Enterprise (SP1)/32-bit version/64-bit version Windows 7 Home Premium/Professional/Enterprise/Ultimate/32-bit version/64-bit version Windows 8/Pro/Enterprise(32/64bit) PC system requirements Processor: 2 GHz or faster System memory (RAM): 1 GB RAM or more Hard disk: 10 MB or more (additional space is needed for recording) Sound card: 8-bit full duplex, Direct Sound compatible Display: 1024 x 768 or greater Run-time: Microsoft ®.NET Framework 2.0 or later Network: 10BASE-T/100BASE-TX Ethernet TCP/IPv4, UDP/IPv4, SIP, Others Protocol 320 k to 8 Mbps (per IP Video Intercom Adaptor) Network bandwidth English, French, Spanish, German, Dutch, Italian, Japanese Language Internet Explorer 6.0 or later (with Internet Options SSL 3.0 enabled) Internet Explorer OS 150 JKW-IP 200 Specifications Power source Power supply Consumption *2 *1 Option device input specifications N/O or N/C dry closure contact Input method (Start signal only detection method) 100 mS or more Detection confirmation time During N/O dry closure: 700d or less Contact resistance During N/C dry closure: 3Kd or more 10 mA or less Terminal short current 20V or less (when open between terminals) Voltage between terminals 18V DC PS-1820 Max. 200mA 35.5 12 Hands-free Color Video Intercom, Picture Memory DOOR Features ROOM • Two doors & three monitors (3-1/2 inch) • Total hands-free communication, auto-voice actuation • Built-in picture memory; Record visitor both automatically & manually • Voice memo; Internal short voice messages can be recorded and played back 3 JF-2MED 2 Door station Master station COLOR VIDEO ENTRY SECURITY 4 2 2 2 IER-2 Call extension m P.98 PT JF-DV PS18 Vandal-resistant video door station, surface mount JF-2MED Master station w/color monitor and picture memory 2 Access Contorol m P.95 AC-10S or JF-DVF Vandal-resistant video door station flush mount Access control keypad, surface mount or AC-10F JF-D JF-DA Access control keypad, flush mount Audio only door station Standard video door station JF-DV + AC-10S Power supply PS-1820 m P.99 Communication network Wiring JF-DV 100m / 1.0mma JF-DV JF-2HD 100m / 1.0mma JF-2MED 2 2 JF-2SD JF-2MED or 2 A1 A2 NP A1 A2 A1 A2 SUB B1 B2 CALL EXT S S EL-12S M (BR) (RD) JF-2SD 4 JF-2SD JF-2SD or 2 PS18 DOOR2 NP JF-2HD 2 IER-2 DOOR1 A1 A2 4 2 JF-DVF M JF-2HD RELEASE NP IER-2 1 E ON OFF ON OFF SUB IN SUB IN B1 B2 SUB OUT B1 B2 B1 B2 SUB OUT B1 B2 L L PT PS18 DC18V DC18V JF-2HD JF-DVF Selective control of door release at communicating Door station. All-Call the inside stations by voice, then talk individually. RY-3DL Connection EL-12S Picture memory 3/16 2006 02 DE C 18 45 8 shots/picture JF-2MED RY-3DL EL-12S PT L1 C1 L1 L2 C2 L2 b1 b2 b3 L D1 E D2 OG YE GR BR RD b1 b2 E L L DC18V PRE SS THE TALK BUTTO N TO E ND BR: Brown RD: Red OG: Orange YE: Yellow GR: Green PS18 : PS-1820: PT AC Transformer 13 PS18 • Message for entrance; Outgoing messages can be recorded and sent out at the door station manually • Streamlined & Thin design, only 32 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions • Visual monitoring with audio for 1 minute • External sensor connectable for notifying and pictograph on monitor • Instant voice call-in with image • • • • • • • • Different chimes to indicate which door is calling Press-to-talk operation available All-Call for internal communication Transfer of door station call to other inside stations Selective door release control (with RY-3DL) Optional audio sub master station (JF-2SD) Audio door station in lieu of 2nd video door station Option - Option button, Video signal (NTSC) output, External talk switch, press-to-talk restriction Lineup Sub station JF-2HD JF-2HD 4 RY-3DL JBW-BA KAW-D EL-12S Door release adaptor m P.6 or 2 or Long distance adaptor *Max. 300m away from Master to Door 2 JF-2SD JF-2SD Audio sub master station Audio sub master station 30k angled box m P.97 JBW-D Electric door strike m P.98 COLOR VIDEO ENTRY SECURITY Sub master station w/color monitor Sub master station w/color monitor 15k angled box Boxed sets JFS-2AED: JF-2MED, JF-DA, PS-2420 JFS-2AEDV: JF-2MED, JF-DV, PS-2420 JFS-2AEDF: JF-2MED, JF-DVF, PS-2420 AE7090210B AE7090210G AIPHONE approved product wire m P.100 Unit dimensions JF-2SD 173 90 32 5.5 209 (1) (2) (3) 65cm 70cm 25 98 JF-DA 25 65cm 50cm 95cm JF-D 131 JF-DVF JF-DA, JF-DV, JF-DVF 130 135 Image view area 27 JF-DV 160 179 JF-2MED, JF-2HD (1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only) 99 45 29 25 Cable 33 Power source Power supply Consumption Calling Communication 61 42 74 AC-10F 100 125 98 Specifications (JF-2MED) 140 122.5 55 68.5 AC-10S 28.5 RY-3DL JBW-BA 132 88 40 108.5 120 83.5 135 IER-2 98 117 5 45 Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed. Video monitor Scanning line Night viewing Door release Wiring Wire type Wiring distance 18V DC PS-1820 Max. 400mA (JF-2MED). Max. 220mA (JF-2HD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3-1/2 inch direct-view TFT color LCD. 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. AIPHONE approved product wire: AE7090210B, AE7090210G Master to door: 50m (0.65mma) 100m (1.0mma) Master to farthest sub: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma) 14 Hands-free Color Video Intercom MASTER DOOR 120 AX 8 Door station Central exchange unit Cat5e COLOR VIDEO ENTRY SECURITY 2 Cat5e PT 2 PS24 AX-084C PS24 Central exchange unit, 4 masters and 8 doors AX-248C (Photo) AX-DV Central exchange unit, 8 masters and 24 doors Color video door station surface mount AX-DM AX-DV-P Audio door station Mullion type Color video door station w/space for embed proximity reader AX-320C Add-on exchange unit, 32 doors PT AX-DVF Color video door station flush mount AX-DVF-P Color video door station w/space for embed proximity reader Features • All wired on CAT5e, homerun cabling • Total hands-free, auto-voice actuation, communication or Press-to-talk operataion • Two talk channels and two video channels • Communication privacy • Masters available with 3.5-inch color TFT LCD • Selective door release • Master-to-master selective calling and All Call • Standard or Priority call levels from door stations • Scan monitoring:Hands-free audio/visual monitoring • Video output from CEU and AX-8MV • Integrate with CCTV, Access control etc. • PC interface for programming and event logging • Rack or wall mountable CEU • Compatible with IE Series door stations • Optional features: headset, footswitch, and PC remote control Power supply PS-2420 IE-JA Audio door station m P.100 Wiring 300m Door #1 AX-DV 300m Cat5e Cat5e RJ-45 RJ-45 Master #8 AX-8MV AX-248C Door #24 AX-DVF Cat5e Cat5e RJ-45 2 2 Door #1 AX-DV Master #1 AX-8MV RJ-45 N N Master #1 AX-8MV RJ-45 Cat5e AX-248C M RJ-45 H Communication network AX-DV AX-8MV AX-8MV AX-DVF + -+- Cat5e Door #24 AX-DVF RJ-45 Video signal M AX-DM Monitor Calling & communication (w/video from door) Door release 15 N N Cat5e N : PS-2420 H : AC transformer Cat5e H RJ-45 Master #8 AX-8MV Lineup Master station EL-12S AX-8MV Electric door strike m P.98 AX-16SW 8-call color monitor master station 16-call add-on selector AX-8MV-W (white) Cat5e AC-10S Access control keypad, surface mount m P.95 AX-8MV, AX-16SW AX-8M COLOR VIDEO ENTRY SECURITY Cat5e AC-10F 8-call audio master station Access control keypad, flush mount m P.95 Unit dimensions AX-8MV(-W) Image view area AX-8M • AX-DV, AX-DVF, AX-DV-P, AX-DVF-P ★ 175 175 185cm 65cm ★ ★ 120cm 194 63 150cm 63 194 ★ 95cm 50cm ★ AX-16SW AX-320C AX-084C, AX-248C 88 85 Calling 63 AX-DV-P AX-DVF 245 195 AX-DV 100 Power source Power supply Current consumption 25 100 2 45 130 98 1-gang 28 IE-JA 146 2 45 22.5 115 43 116 Video monitor Scaning lines Night viewing Door release contact Outside video output IF-DA 160 295 146 25 AX-DM AX-DVF-P Communication 246 86 approximate Specifications (AX) 420 426 88 85 175 420 426 50cm 2-gang Wiring Wiring distance 24V DC, 2A (Two Power supplies per video system) PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5-inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300m (CAT5e) CEU to master: 300m (CAT5e) 10 16 Hands-Free Color Video Multi-tenant Recording, Zoom & PanTilt features GT The GT Series provides building complexes with high performance security & usability. A variety of models adapt to almost any type of building. Wide and Zoom & PanTilt Panorama Wide Angle View To provide effective security, the GT series features a wide angle camera that enables you to see an innovative panoramic view! People standing on sides and people of all heights can be easily identified. MULTI-TENANT BUILDING ENTRY SECURITY Zoom To see details, switch to Zoom mode. Switching between Wide and With conventional series Zoom mode can be easily done at the press of a button. Innovative Wide View of Approx. 170k PanTilt PAN/TILT is available to change the camera angle in Zoom mode. Recording Automatic Recording Manual Recording Works any time, even during your absence. Records 6 images per Record picture as required. The recording picture sequence. Up to 40 picture sequences can be recorded. starts when you press the REC button while monitoring or talking to a visitor. Playing The play LED flashes when there are autorecorded pictures.Press the PLAY button to play. Security Only the master station with the recording function can be Emergency button Door sensor.1 connected with 3 security lines. It can also be connected with an emergency button. When sensing an input from the GT-2C button, the alarm will be triggered after the set time. Security guard station GT-MK 17 * The design and specifications are subject to change without notice for improvement. Door sensor.2 Building System with High Degree of Usability for Visitors and Other Features Audio & Visual Guidance The Entrance Station features both audio and visual guidance, so any visitor knows the present situation. The audio guide is available in 6 languages (English, French, German, Spanish, Dutch, and Italian). Please speak now. Door open. Supports Hearing Aid with T-mode MULTI-TENANT BUILDING ENTRY SECURITY Call in progress. A T-coil mode is now available with the GT Series. If your hearing aid GT-DA-L features T-mode, the Visual guide GT-DM sound from the GT room station is much There are projections on the & clearer than other buttons to help intercoms. visually impaired visitors. Doorbell connections You can connect stations to Up to 4 Internal Stations can be installed per tenant. Doorbell your existing doorbell. GT-2C JK-DV GT-2H GT-2C GT-2H GT-2H Capacity Standard Expanded 48 500 Tenant station Tenant station Capacity Standard Expanded Hands-free color monitor tenant station GT-2C-L GT-DM 5 16 Entrance station Security guard station Entrance station Capacity Standard Expanded 2 4 Security guard station Security guard station GT-MK 18 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt System Configuration Standard system Divided cabling with GT-4Z Trunk line No.1 5 Entrance stations 2 Security guard stations 48 Tenant stations 1Px2 1Px2 1Px2 1Px2 MULTI-TENANT BUILDING ENTRY SECURITY PS24 Doorbell GT-1C GT-1C 1Px2 GT-2C 1Px2 1Px2 Doorbell Doorbell PS24 GT-1C 1Px2 GT-2C 1Px2 GT-2C JK-DV or 1Px2 GT-4Z Doorbell PS24 GT-2C JK-DV or 1Px2 1Px2 1Px2 Doorbell 1Px2 Doorbell GT-2C GT-1C PS24 JK-DV or GT-2C PS24 GT-2H GT-2H PS24 GT-2H Tenant 300m / 0.8mma 1Px2 1Px2 GT-2C No.2~5 Doorbell 150m / 0.8mma 1Px2 GT-BC 1P PS24 CCTV camera Coaxial cable GT-VBC PS24 1P 1P PS24 1P 1P Power supply GT-DM Entrance Station : Max. 5 Wiring distance: Entrance station - Bus & Video control unit 300m Video control unit - Farthest Video Tenant station 150m (Expandable with additional Video control unit) Bus control unit - Farthest Audio Tenant station 300m Accumulated total Audio wiring distance 2,500m 19 PS24 PS24 1Px2 Doorbell 1Px2 Doorbell GT-1C 1Px2 PS24 JK-DV or 1Px2 GT-2C GT-2C PS24 1Px2 GT-4Z JK-DV or Doorbell JK-DV or 1Px2 Doorbell Doorbell 1Px2 1Px2 GT-4Z JK-DV or GT-2C Monitor to monitor cabling Trunk line No.6 On the same trunk line, do not have two wiring methods mixed, Divided cabling with GT-4Z & Monitor to monitor cabling GT-MK GT-MK Security Guard Station : Max. 2 Expanded system 16 Entrance stations, 2 common trunk lines (8 each per common line) 4 Security guard stations, 2 common trunk lines (2 each per common line) 500 Tenant stations, 4 sub trunk lines (125 each per sub trunk line) Trunk line No.1 No.6 No.1 Tenant station Max.125 /SUB line No.6 Tenant station Max. 125 /SUB line PS24 PS24 1Px2 PS24 PS24 1Px2 PS24 No.2~5 1Px2 GT-BC 1Px2 PS24 PS24 1Px2 1Px2 GT-VBC PS24 No.2~5 GT-BC 1Px2 GT-VBC PS24 SUB 1B & 2A 300m / 0.8mma 1Px2 1Px2 SUB 1A SUB 2B COMMON 1 1Px2 COMMON 1 1Px2 1P 1P PS24 PS24 1P CCTV camera GT-BCX PS24 1Px2 1P GT-MK GT-MK Security Guard Station Max. 2/COMMON line GT-BC PS24 1Px2 PS24 1P GT-VBX Power Coaxial supply cable Entrance Station Max. 8/COMMON line COMMON 2 150m / 0.8mma 1P MULTI-TENANT BUILDING ENTRY SECURITY PS24 1Px2 GT-BC PS24 COMMON 2 1P PS24 CCTV camera Power Coaxial supply cable Entrance Station Max. 8/COMMON line 1P 1P 1P GT-MK GT-MK Security Guard Station Max. 2/COMMON line Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m Expanded Video control unit - Video Bus control unit 150m Expanded Bus control unit - Bus control unit 300m Accumulated total Audio wiring distance 2,500m/SUB line 20 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Entrance station All-in-one type Module type Digital name scrolling Direct-select call button Color camera Microphone Color camera White light LED White light LED Zinc die-cast panel Speaker In-use LED Speaker In-use LED Guidance display Display Microphone MULTI-TENANT BUILDING ENTRY SECURITY Call button Access control/ room number dialing keypad Directory scroll/ Cancel/ Call buttons Directory card & cover Motion sensor Audio Module GT-DP Audio panel for GT-DA GT-DP-L Audio panel for GT-DA-L Camera Module GT-VP Camera panel GT-DA Audio module GT-DA-L Audio module W / guide display Access control keypad module GT-VA Camera module GT-AC Access control keypad module GT-HID Card reader panel Option GT-DM Entrance station with camera with name scroll GF-AP Address panel Address module GF-BP Blank panel Specifications (GT-DM) Specifications (GT-DA,GT-VA) Specifications (GT-SW,GT-10K,GT-AD) Power source Wiring Type of cable Lighting Material 24V DC, supplied by PS-2420 Video monitor 3.5-inch color LCD Camera unit Complementary metal oxide semiconductor (CMOS) Communication AUTOMATIC (Hands-free) Mounting Flush-mounting Material Stainless Mounting Material 21 GT-AD Two single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B, 3B and GT-4B, and GF-2F, 3F and GT-4F Fire-retardant plastic Yellow LED Fire-retardant plastic Specifications (GT-NS) Power source Material 24V DC, supplied by PS-2420 Fire-retardant plastic l 170° range wide view camera l Audio & visual guidance assists the visitor to know the present status and go on to the next step at ease. l Searches of names and number using the keypad l Customer programmable welcome messages can also be shown l 6 languages (English, French, German, Spanish, Dutch & Italian) are available for audio guidance and messages on Guidance display l White light LED illuminates the visitor automatically in low-light conditions Digital name scrolling White light LED Guidance display VFD Display Directory scroll/ Cancel/ Call buttons Access control/ room number dialing keypad GT-4F GT-4B GF-3F GF-3B 4-module front frame 3-module front frame GF-2F 2-module front frame 4-module back box 3-module back box GF-2B 2-module back box Digital name scrolling module GT-NSP-L Display module panel GT-NS Digital name scroll display module Front frame & back box GF-10KP 10-key module panel MULTI-TENANT BUILDING ENTRY SECURITY Keypad illumination GT-10K 10-key module SBX-GTDM Call switch Module Surface Mount Box for GT-DM GT-nH Rain hood GT-nHB Hooded surface-mount box GF-nBA Surface-mount box GF-1P 1-call panel GF-2P 2-call panel GF-3P 3-call panel GF-4P 4-call panel GT-SW Call switch module Easy system setting on a PC l Settings can be made from a PC by using the Setting Software. l Connecting the unit and a PC via USB l Supported OS: Windows XP (SP3 or higher), Windows VISTA (SP2 or higher), Windows 7, Windows 8 22 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Unit dimensions GT-DM Audio/Video + Name scroll Audio/Video + Name scroll 410 425 320 225 4-call 270 16 135 60 GT-VP 93 8 110 8 108 110 GT-SW 93 95.2 90.5 GF-4P GT-VA 108 18.5 38 15.8 110 135 106 4.5 38 44 GT-104HB 23 155 68 GF-10KP 96.1 90.5 GT-10K 110 16 GT-104H 155 14.4 10.5 443 9 110 GT-NSP-L 38 95.2 GT-NS 106 4.5 38 443 106 90.5 MULTI-TENANT BUILDING ENTRY SECURITY 95 GT-DA/GT-DA-L 11 38 95 GT-DP/GT-DP-L 400 8 GT-4B GT-4F 44 44 44 425 150 16 135 16 110 15.5 Security camera You can select one of the cameras placed at the entrance, and monitor the entrance. This allows you to confirm visitors from various angles, thus enabling blocking intrusion by suspicious individuals. CCTV camera Video Monitoring Wiring GT-DM CN2 CCTV camera 2C (Brown) (Red) Entrance station GT-2C-L GT-VA CN4 CCTV camera 23 2C (Brown) (Red) Entrance station components Number of calling button (2) (3) (4) (5) (6) (7) 8. 12. 16. 20. 24. 1 1 1 1 1 1 1 1 - 1 1 1 1 2 2 1 1 - 1 1 1 1 3 3 2 2 - 1 1 1 1 4 4 2 2 - 1 1 1 1 5 5 2 2 - 1 1 1 1 6 6 3 3 1 - - 1 - 1 - - - - - - - - 1 1 1 1 25.~48. GT-NS, GT-10K 1 1 1 1 1 1 - For more than 7 GT-SW, install additional power supply & special device required. Contact local AIPHONE distributor (1) Camera (2) Audio (3) Call switch (4) 3-module Front frame (5) 4-module Front frame (6) Option (7) Digital name scroll GF-3F . GT-nHB . GT-nH Mounting GF-3B GT-DA GT-DP W 23 H H H (3) GT-SW H (5) (2) (1) 61 68 (4) GF-4P W . GF-nBA W W 45 GT-102H/HB 243 155 GT-202H/HB 243 290 GT-103H/HB 338 155 GT-203H/HB 338 290 GF-202BA 229 274 GT-303HB 338 425 GF-103BA 324 139 GT-104H/HB 443 155 GF-203BA 324 274 H W GF-102BA 229 139 (1) Tamper-proof screw & screwdriver(supplied with GT-BC) (2) Module-mounting bracket(supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance. Back box 1. 2. 3. 4. GF-2B/3B W GT-4B x1 110 x2 245 x3 380 x4 295 515 mm x5 650 x6 785 x7 920 x8 1055 x9 1190 44mm (1) (1) 200 mm 400 mm 25mm 25mm W W (2) 44mm W (2) 44mm 25mm (2) Interconnecting Modules with Plug-in Conectors Image view area (WIDE) GT-VA (ZOOM & PanTilt) approx. 200cm Zoom (down) approx. 85cm 155cm CN1 approx. 225cm CN3 Zoom (up) approx. 70cm approx. 95cm 50cm GT-NS CN3 approx. 85cm approx. 105cm 155cm 1. One 4-module back boxes 2. Two 2-module back boxes 3. Three 3-module back boxes 4. Back box total width (mm) (1) Joint pipe(x2) (2) Do not recess back box more than 15mm. MULTI-TENANT BUILDING ENTRY SECURITY GT-VA GT-VP GT-DA(-L) GT-DP(-L) GT-SW GF-4P GF-3F GF-3B GT-4F GT-4B GF-BP GT-AD GF-AP GT-NS GT-NSP-L GT-10K GF-10KP (1) 4. 50cm approx. 75cm CN1 CN2 GT-DA-L GT-10K CN3 CN1 50cm approx. 170˚ approx. 90cm approx. 130cm approx. 10cm Zoom (right) approx. 130cm CN1 CN2 CN2 CN1 CN1 CN2 CN2 CN1 approx. 10cm Zoom (left) 24 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Hands-free color monitor tenant station w/ picture memory Picture memory or GT-2C-L Features (GT-2C-L, GT-2C) Exclusive functions available for GT-2C-L/GT-2C (In addition to GT-1C(-L)) • Video recording from an entrance station or video door station • Sensors (commercially available) can be connected for security • Up to 4 monitor stations can be linked per Tenant • Individual Video door station/audio door station can be connected. • Internal call and communication Hearing aid GT-2C Option Max. 3 sub master monitor stations (GT-2H-L or GT-2H) can be connected (total of 4 per room) MULTI-TENANT BUILDING ENTRY SECURITY Hearing aid Other basic functions • Refer to the features for the GT-1C-L/GT-1C. Items listed in the corresponding section can be used as common basic functions. GT-2H(-L) + + or w/o picture memory Features (GT-1C-L, GT-1C) Hearing aid or GT-1C GT-1C-L Option • Zoom/wide and pan & tilt video monitoring function • 3.5-inch LCD for operation and video monitoring • Hands-free communication, auto-voice actuation • Press-to-talk communication is available • Video image adjusting function • Monitoring an entrance station or video door station • Lighting control for a call from entrance station • Releasing door lock • Security guard call • Auto-entry (Doctor call) • Optional handset for private communication Max. 3 additional stations (*) can be connected (total of 4 per room) Common items Optional Handset + Specifications (GT-2C-L, GT-2C, GT-1C-L, GT-1C, GT-2H-L, GT-2H) Power source Video monitor Wiring Mounting Material Unit dimensions GT-2C-L, GT-2C, GT-1C-L, GT-1C, GT-2H-L, GT-2H GT-HS 140 177 GT-HS GT-2C-L, GT-2C: 24V DC, supplied by PS-2420 GT-2H-L, GT-2H: 24V DC, supplied by GT-2C-L, GT-2C GT-1C-L, GT-1C: 24V DC, supplied from Bus control unit, GT-BC & GT-VBC 3.5-inch TFT color LCD Two Single –pair cables common Wall-mounting only Fire-retardant plastic 140 + (*) Max. 1 additional monitor station can be installed (GT-1C, GT-1C-L or GT-1M-L). Max. 3 additional audio stations can be installed (GT-1A or GT-1D). If 1 additional monitor is installed, max. 2 additional audio stations can be installed. 190 30 45 25 46 Features (GT-1M-L) • 3.5-inch LCD for operation and video monitoring • Lighting control for a call from entrance station • Monitoring an entrance station • Releasing door lock • Security guard call • Auto-entry (Doctor call) Hearing aid Unit dimensions GT-1M-L 210 Color monitor tenant station Specifications (GT-1M-L) GT-1M-L Monitor tenant station 24V DC, supplied from Bus control unit, GT-BC & GT-VBC Video monitor 3.5-inch color LCD Wiring Two Single-pair cables common Mounting Wall-mounting only Material Fire-retardant plastic 215 Features (GT-1A, GT-1D) Unit dimensions • Lighting control for a call from entrance station • Monitoring an entrance station • Releasing door lock • Auto-entry (Doctor call) 175 GT-1A 125 GT-1A Audio tenant station 200 89 GT-1D Audio tenant station 63 Specifications (GT-1A) Specifications (GT-1D) Power source 24V DC, supplied from Bus control units GT-BC Power source 24V DC, supplied from Bus control unit GT-BC Wiring Single-pair cable common Mounting Wall-mounting only Wiring Mounting Single-pair cable common Wall-mounting only Material Fire-retardant plastic Material Fire-retardant plastic Trunk line Functions Buzzer Tenant master station Panic alarm Cal GT-2C 1Px2 O 1Px2 PANIC CALL switch &C om ory em n larm g m atio ic a callin unic Pan ce mm Co sen Ab ng & li Cal Cal ling &C Do or r om ele mu Mo a nic se nito atio rin n g (a udi o/ vid eo) ling mu nic atio Calling & Communication Door release Monitoring (audio) Reception mode function Monitor to monitor cabling Divided cabling with GT-4Z External signaling Video door station or Entrance station 32 GT-1D Hearing aid Doorbell 69 MULTI-TENANT BUILDING ENTRY SECURITY Audio tenant station Power source n PS24 1Px2 1Px2 GT-2C GT-2C PS24 GT-2C PS24 1Px2 GT-2C PS24 GT-2C GT-4Z GT-2H 1Px2 PS24 GT-2C Only available to connect on a trunk line with GT-4Z used 1Px2 1Px2 PS24 1Px2 On the same trunk line do not have two wiring methods mixed, Divided cabling with GT-4Z & Monitor to monitor cabling Security guard station 26 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Video door station Features l 170krange wide view camera l Directory card with backlight (JK-DV, JK-DVF) l White light LED illuminates the visitor automatically in low-light conditions Specifications (JK-DA, JK-DV, JK-DVF) JK-DA Wide and Zoom & PanTilt video door station, surface mount Power source Type of communication Camera Minimum illumination Camera angle Mounting Material Supplied from Tenant station Open voice hands-free communication 1/4-inch color CMOS 5 Lux Wide: 170k (approx.)(Horizontal) JK-DA, JK-DV: Surface wall mount (Directly to wall or electrical box) JK-DVF: Flush mount JK-DA: Fire-retardant PC + ABS plastic JK-DV: Zinc diecasting JK-DVF: Front panel Stainless steel JK-DV Wide and Zoom & PanTilt Vandal resistant video door station, surface mount 29.5 173 JK-DV 129 JK-DA 97 JK-DVF 35.5 98 25 135 Image view area Refer to the descriptions for the image view area. m P.10 JK-DVF Wide and Zoom & PanTilt Vandal resistant video door station, flush mount Door station Specifications Power source Type of Communication Mounting Material Unit dimensions GT-D GT-D 130 Audio only door station 98 27 8 209 MULTI-TENANT BUILDING ENTRY SECURITY Unit dimensions 28.5 Supplied from Tenant station Open voice hands-free communication Surface wall mount Fire-retardant PC + ABS plastic 45 Security guard station GT-MK Security guard station Features Unit dimensions l Call to tenant station GT-MK l Digital display shows name of tenant & 210 number l Entrance station call-ins made to the indoor unit can be automatically forwarded to the security guard station. l Absence call-in memory stored with Callback 215 69 l Option (GT-MK) Specifications Doorbell at door with different call tone User-optional device can be controlled with Power source 24V DC, supplied by PS-2420 SERVICE button, such as Max. 16 letters for names; English VFD display -light on and off at entry way to elevator (Up to 32 characters can be registered.), l Receive a Panic call from tenant station French, German, Spanish, Dutch & Italian Desk-top stand 2 single-pair cables 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Mounting Wall-mounting or Desk-top mounting on GFW-S Fire-retardant plastic Material Control units System layout example BUS (Audio/Video) MAX.6 Divided cabling with GT-4Z 2 3 4 5 6 150m 1 1P(Audio) 1P(Video) Monitor to monitor cabling Expand pos. GT-2C GT-4Z 1Px2 1Px2 GT-2C PS24 GT-2C GT-2C PS24 PS24 GT-2C PS24 GT-2C GT-BC GT-BC Bus control unit EXP On a single trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GT-4Z STD max. 2 GT-VBC PS24 PS24 GT-VBC 150m PS24 GT-BC GT-VBC PS24 PS24 PS24 300m 1Px3 PS24 PS24 EXP STD MULTI-TENANT BUILDING ENTRY SECURITY GFW-S Wiring Type of cable Standard pos. Wire type GT-VBC Video Bus control unit, expander video control AIPHONE approved product wire: AE7090220B, AE7090220G AE7090210B, AE7090210G or 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Wiring distance GT-BC, GT-VBC to Farthest Entrance station GT-BC, GT-VBC to Farthest Video tenant station GT-BC, GT-VBC to Farthest Audio tenant station GT-BC, GT-VBC to each Power supply Accumulated Audio lines (R1, R2) Total wiring distance Specifications (GT-BC, GT-VBC) Unit dimensions Video 4-zone divider Power source GT-BC, GT-VBC, GT-4Z Consumption Wiring Housing 108.5 GT-4Z 122.5 Distance (Diameter of wires) 300m(0.8mm) 150m(0.8mm) Expandable 150m with additional GT-VBC & Power supply 300m(0.8mm) 5m(0.8mm) 2,500m(0.8mm) 61 24V DC, supplied by PS-2420 900mA. Single-pair cable common Fire-retardant plastic Specifications (GT-4Z) Wiring Material Two Single-pair cables common Fire-retardant plastic 28 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Expanded control units Features l Expandable to max. 500 Tenant stations, 16 Entrance stations, and 4 Security guard stations System layout example GT-BC GT-BCX Expanded Bus control unit PS24 PS24 GT-2C GT-2C GT-VBC GT-BC SUB1B SUB2A PS24 1Px2 SUB1A 1Px2 1Px2 COMMON 1 GT-VBC PS24 SUB2B COMMON 1 PS24 PS24 GT-BCX PS24 GT-VBX GT-MK COMMON 2 GT-MK GT-MK GT-MK PS24 PS24 GT-BC PS24 GT-BC PS24 l COMMON trunk line: Requires one each of GT-BC & Power supply l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations l SUB COMMON trunk line: Max. 125 Tenant stations GT-VBX Expanded video control unit Specifications (GT-BCX, GT-VBX) Unit dimensions Power source GT-BCX: 24V DC, supplied by PS-2420. GT-BCX, GT-VBX GT-VBX: Supplied from GT-BCX 108 MULTI-TENANT BUILDING ENTRY SECURITY 1Px2 COMMON 2 61 210 Wiring Single-pair cable common Material Fire-retardant plastic Power supply Unit dimensions Specifications (PS-2420) PS-2420 Input voltage & Capacity 52 Output voltage 24V DC, 2A 167 90 100-240V AC, 50/60Hz 60W/100-125VA PS-2420 Option GT-RY External signaling relay entrance light, external buzzer 29 W-DIN11 DIN mounting rail for GT-BC, GT-VBC, GT-4Z AC-10S Access control keypad, surface mount m P.99 AC-10F Access control keypad, flush mount m P.99 AE7090220B AE7090220G AE7090210B AE7090210G AIPHONE approved product wire m P.104 GT Lift control adaptor Features l Lift is controllable from tenant station while communicating with entrance station. When door release button is pressed, electric door strike is activated and simultaneously output signal is transmitted to the lift controller or the access controller. The access is authorised only to the floor of communicated tenant station. l Selectable dry contact: Normally Open or Normally Closed l System set up data is programmable on your PC GTW-LC Lift control adaptor * GT-BCX is required to use GTW-LC. Cabling 1P(Audio)*1 1P(Video)*2 1P eas e mm rel Co ) Ca on cti Do or ea (on g& GT-2C ol llin PS24 ntr un Co ica tio n GT-2C GT-VBC Access authorised only to the floor of communicated tenant station GT-BC PS24 MULTI-TENANT BUILDING ENTRY SECURITY Functions Lift Entrance station Connection with GTW-LC, Lift control unit GT-VBX Unit dimensions GT-BC GT-BCX PS24 PS24 Distribution point GTW-LC PS24 GT-BC 108 GT-BC PS24 210 61 GTW-LC Specifications Power source Relay Wiring Material Supplied by GT-BC Output 20 Contact rating 24V AC/DC, 0.5A N/O or N/C dry contact Operating time From 1 to 600 seconds Single-pair cable Fire-retardant plastic PS24 Lift controller Lift GT Expanded system *1. AIPHONE approved product wire: AE7090220B, AE7090210B *2. AIPHONE approved product wire: AE7090220G, AE7090210G PS24 : PS-2420 30 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Cabling 1P(Audio)*1 1P(Video)*2 1P Standard system Capacity 5 Entrance stations 2 Security guard stations 48 Tenant stations Divided cabling with GT-4Z 1Px2 Trunk line No.1 1Px2 1Px2 GT-4Z Monitor to monitor cabling 1Px2 JK-DV Trunk line No.2 JK-DV 1Px2 GT-2C GT-2C or or MULTI-TENANT BUILDING ENTRY SECURITY PS24 Doorbell GT-2C PS24 1Px2 1Px2 Doorbell 1Px2 GT-4Z PS24 1Px2 1Px2 JK-DV JK-DV 1Px2 1Px2 1Px2 or GT-2C Doorbell PS24 GT-2C PS24 GT-2H GT-2H GT-2H GT-2C Max. 4 internal stations can be linked per Tenant PS24 1Px2 1Px2 On the same trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GT-4Z 1Px2 Trunk line No. 3 to 6 1Px2 Distribution R1 point PS24 R2 GT-BC GT-VBC 1Px2 Light control Timer Entrance No. 2 to 5 GT-RY 1P 1Px2 1Px2 AC 1P 1P 1P 1P CCTV camera Light Doorbell Coaxial cable Door release Entrance station PS24 Entrance station Door release Power supply GT-MK Security guard station Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation 31 GT-MK PS24 Security guard station Wiring Divided cabling with GT-4Z Trunk line No.1 GT-4Z B1 OUT B2 A B R1 R2 B1 B2 B1 IN B2 R1 OUT R2 IN 1Px2 R1 R2 H1 H2 A1 A2 + - OUT B1 B2 Power supply A GT-2C IN B1 B2 AC R1 OUT R2 JK-DV A1 A2 or Door bell AC Trunk line No.2 A1 A2 R1 OUT R2 1Px2 JK-DV or R1 IN R2 B1 B2 R1 R2 B1 OUT B2 H1 H2 B1 IN B2 A1 A2 GT-4Z 1Px2 A B1 B2 OUT 1 R1 R2 R1 IN R2 H1 H2 A + - OUT 2 B1 B2 R1 R2 1Px2 AC R1 IN R2 Power supply A1 A2 GT-2C B1 IN B2 SW2 CN4 SW2 CN4 R1 IN R2 H1 OUT H2 H1 OUT H2 A1 A2 H1 H2 H1 IN H2 H1 IN H2 JK-DV A1 A2 + + - - + - AC GT-2H GT-2H + - + + - - Power supply + - + - R1 OUT R2 LINE IN R1 R2 B1 B2 Power supply A GT-2C B1 OUT B2 1Px2 B A 1Px2 B AC Power supply GT-2C B1 OUT B2 B1 IN B2 R1 OUT R2 A GT-2C Door bell R1 OUT R2 + - + - A1 A2 + - Monitor to monitor cabling B1 IN B2 R1 IN R2 A1 A2 1Px2 Trunk line No. 3 to 6 + - + A B AC Power supply GT-2C 1Px2 Distribution point R1 R2 Power supply + - + - GT-BC B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 + - IN1 IN2 IN3 IN4 IN5 SW2 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2 EXP STD GT-VBC AC Video Entrance station No. 3 to 5 1P Doorbell Light control Timer Orange Light AC Blue Orange GT-RY White MULTI-TENANT BUILDING ENTRY SECURITY + - R1 R2 B1 B2 LINE OUT B1 B2 OUT 3 OUT 4 R1 R2 B1 OUT B2 Terminate the last GT-4Z Door release 1Px2 PT Entrance station CN2 A1 A2 R1 R2 ELM ELC ELM BP BP + - GT-DM CN2 A1 A2 R1 R2 ELM ELC ELM BP BP + - GT-DM CCTV camera GT-MK 2nd GT-MK R1 R2 R1 R2 R1 R2 C CE + - R1 R2 C CE + - SW1 AC SW1 + button AC - Power supply + - Power supply AC *1. AIPHONE approved product wire: AE7090220B, AE7090210B *2. AIPHONE approved product wire: AE7090220G, AE7090210G 32 Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Compatibility with the existing system The GT system follows the GH trunk line. Both systems can be mixed for call and communication performance, however the use of some functions are restricted. Some functions are enabled on a single station, and some depends on the system. Main functions that are enabled on a single station GT-2C-L, GT-2C GT-1C-L, GT-1C l Recording function l Selectable call-in tones (2 tones) l 3 add-on master stations l Individual door station l Selectable call-in tones (5 tones) l Security or general purpose call GT-1M-L GT-1D l Handset T-mode communication l Handset T-mode communication MULTI-TENANT BUILDING ENTRY SECURITY New entrance station GT-MK l Audio guidance l Handset T-mode communication l Room number search in numerical order l External output setting l Night illumination normally-off l Call-restricting function l The external door release button l Room number search in numerical order Main functions that depend on the system and the old GH and new GT system compatibility list Existing GH and new GT system The existing GH compatibility list entrance The existing GH security guard stations and stations and the new GT system the new GT system Zoom/wide and pan & tilt ✓ Video image adjusting function for viewability ✓ Calling a security guard station individually (that has the recording function only) ✓ Absence call-in records from the security guard station (that has the recording function only) ✓ Releasing the door while being called-in The existing GH tenant stations and the new GT system The new GT entrance stations and the existing GH system ✓ The new GT security guard stations and the existing GH system The new GT tenant stations and the existing GH system ✓ ✓ Confirmation sound and LED indication at link setting Switching the security camera ✓ ✓ ✓ *Transferring link setting information from the new system to the old system is not possible. 33 INTEGRATED SECURITY & COMMUNICATION SYSTEM Innovative network-based security management systems. Manage not only your door entry security, but also internal communication through one system via a local network or the internet to dramatically improve security efficiency. Find Out the Solutions for Your Security Needs. Large Corporations Protect staff by giving them the advantage to safely confirm the identity of visitors and vendors before granting access into the building. Airports Communications between several departments at separated places can be smoothly realized. Schools Shopping Mall Internal communication between tenants can be easily done. It contributes to prompt action in emergency conditions, such as quick call to a disaster control center. Hospitals Increase staff efficiency by controlling various entrances from a central location. Easily transfer responsibilities to another location or individual. Parking Garages Assist visitors and monitor multiple garage entrances from remote locations during or after hours. Lineup IP Network Audio - Video Intercom System IX series P35l Security IP Video Intercom System INTEGRATED SECURITY & COMMUNICATION SYSTEM Broadcast messages throughout the school or to a particular classroom with the choice of either a hands-free or handset reply. Integratable Audio / Video Security IS series AX series P47l P59l 34 IP Network Audio - Video Intercom System IX Greater flexibility, covering more applications. The IX System – getting the job done for a wide range of business applications, while achieving connection and integration with third-party IP systems. Full IP-network compatibility VPN/LAN INTEGRATED SECURITY & COMMUNICATION SYSTEM Security enhanced Integration Network Camera Card Reader 35 Access Control VMS/NVR Emergency Call Paging Full IP-network compatibility, simple installation, and greater flexibility. Enables to communicate between an infinite number of door/master stations with no distance limitations. Helps save money as no server is required to build a system. No server configuration results in space savings, reduced installation time, and lower cost Unlimited number of devices IP addresses for up to 500 devices can be registered for each master station – plenty of coverage even in large-scale applications. X 500 Simply connect the units to Power over Ethernet (PoE) switches. This means no need for a dedicated server, with the additional benefit of eliminating the risk of system downtime due to server malfunction. PoE design LAN and VPN connections enable implementation over extensive areas and between remote locations. This system allows for closed circuit communication and central control in large facilities, between corporate and satellite offices, and any type of application with multiple locations. Electrical power is supplied over the LAN port connection. INTEGRATED SECURITY & COMMUNICATION SYSTEM No wiring-distance limitations Server Integration with other IP-based security systems Using an existing IP infrastructure, IX System can be integrated with Video Management System, Access Control System, and Network Camera System, etc. Combining security components saves time and resources during set-up and training. Compatible with third-party systems This system is compatible with the ONVIF Profile S-established interface specifications for network camera equipment. This allows the intercom to be used with third-party systems, enabling interoperability of integrated IP systems. The open API allows for configuring IP systems with greater flexibility. Examples of Integration IX-MV An ONVIF compatible VMS/NVR system Access control system Use with a Video Management System and Access Control 24 Interconnection with an ONVIF Profile S-compatible network camera system lets you transform door station into surveillance cameras for facial identification of visitors. Integrate with video management systems for 24/7 recording. Integration with third-party access control is also possible. *VMS (video management system): XProtect® by Milestone Systems *Access control:OnGuard® by Lenel 7 Clearly identify visitors with both the intercom and Network camera. 36 IP Network Audio - Video Intercom System Custom settings for a variety of features. Call Queuing Master stations can receive up to 20 incoming calls simultaneously. Caller information can be displayed on a call queue list, making it possible to respond selectively to high-priority calls. Page to all stations or individual groups Page to all stations and page to preset specific groups is possible. A third-party paging amplifier can be connected for additional coverage. Group No.1 Group No.2 INTEGRATED SECURITY & COMMUNICATION SYSTEM Group No.49 Group No.50 PA amplifier Speaker Unicast / Multicast Customize with prerecorded messages According to an infrastructure, there is a choice of sending data via Unicast or Multicast. Paging to all stations can be done using Multicast, and for Unicast communication, paging up to 50 stations is possible. Create and import custom audio files for use as unique voice messages. For visitors at door stations, voice messages let them know that door is open. Send E-mail For security guards/receptions at master stations, voice messages help them to identify incoming calls instantly. When master stations are called, IX System can send an E-mail attached with the visitor’s picture up to 3 E-mail addresses. Error in the system and health check report can be also sent via E-mail. Door is open Call from customer entry point Notification of call and communication status Indicator lamps and sounds or voice messages provide notification of call and communication status for security and peace of mind. Call in Progress The Call indicator flash in orange. Communication in Progress The Communication indicator flash in green. 37 A wide array of call transfer features The system offers an array of call transfer features that can be set to meet the application. 1Communication Manual transfer 2Transfer A call from a door station can be placed on hold and transfered to another master station manually by the user. 3Communication Delay transfer Transfer If no response occurs within a set interval, call is automatically transfered to a pre-programmed master station. No response within a set interval Transfer Call is automatically transfered to a different master station immediately. Schedule transfer Call is automatically transfered to a preset master station during scheduled times, such as after normal business hours. Office hours After hours Security company Transfer Usage-specific individual calls and simultaneous calls to multiple devices Door station can call up to 20 master stations simultaneously. Master station can call up to 50 other master stations in a group simultaneously. Receptionist Entrance Individual call Up to 50 master stations can be registered in a group. Maximum 50 groups can be registered. INTEGRATED SECURITY & COMMUNICATION SYSTEM Absent transfer Group call Individual call Office No.1 Office No.2 Office No.3 38 IP Network Audio - Video Intercom System Examples of Popular Applications Airports All-in-one system for Internal communication, Access Control for restricted area, and Video surveillance. Employees can communicate with each other efficiently and effectively. Access at public entrances can be controlled with facial identification. Integration with access control is also possible. Security Control Center 2014.01.23 AM09:01 office door open 2014.01.24 AM09:05 office door open 2014.01.24 PM05:09 office door open 2014.01.25 AM09:01 office door open 2014.01.25 AM10:06 office door open 2014.01.25 PM03:21 office door open 2014.01.25 PM07:20 office door open 2014.01.23 AM09:01 office door open Name John Smith XXXXXXXXXXXXXXX XXXXXXXXXXXXXX XXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXX Staff Room IX-MV IX-MV IX-DF-P IX-DF-P VMS Access Control Entrance IX-DF Entrance INTEGRATED SECURITY & COMMUNICATION SYSTEM IX-DF IX-DF Railways All-in-one system for Help points, Communication between distant stations, and Video surveillance. Response can be made to calls and queries from ticket machines, ticket gates, and platforms with video monitoring. Communication between distant stations is also possible. Station A Station B Control room IX-MV IX-MV IX-MV VMS IX-DF Station C Virtual Private Network IX-MV IX-DA IX-DF 39 IX-DA IX-MV Schools All-in-one system for Door Entry management, Call transfer for after hours, and Emergency paging. Management of entry and exit points integrated with access control can be accomplished. The system can also be used to enable teachers and staff members to easily communicate with one another. After hours control for schools within the district can be performed at a central control site. School A Security Camera Security Camera School B Security Camera School C Virtual Private Network Central Control Center Administration Office Classroom IX-DF IX-MV VMS IX-MV Parking facilities All-in-one system for Emergency call, Remote control of distant parkings, and Video surveillance. Audio communication and video identification allows for immediate where assistance is needed. Crime prevention can be enhanced further through simultaneous installation of network cameras. Security Control Center Security Camera IX-MV IX-DF Security Camera VMS IX-DF Security Camera Virtual Private Network IX-DF Security Camera INTEGRATED SECURITY & COMMUNICATION SYSTEM IX-MV IX-MV IX-DF Security Camera IX-DA Security Camera Emergency Call 40 IP Network Audio - Video Intercom System System Configuration Virtual Private Network WAN system LAN system Router CAT5e/6 PoE Switch CAT5e/6 100m CAT5e/6 100m IX-MV CAT5e/6 CAT5e/6 CAT5e/6 100m IX-DA 100m 100m IX-DF IX-BA PoE Switch Contact input Relay output Relay output Audio output Contact input Relay output INTEGRATED SECURITY & COMMUNICATION SYSTEM PA amplifier Electric lock Speaker Electric lock IX-SS Audio output PA amplifier Electric lock Speaker 100m IX-DF-P CAT5e/6 2014.01.23 2014.01.24 2014.01.24 2014.01.25 2014.01.25 2014.01.25 2014.01.25 2014.01.23 AM09:01 office door open AM09:05 office door open PM05:09 office door open AM09:01 office door open AM10:06 office door open PM03:21 office door open PM07:20 office door open AM09:01 office door open Name John Smith XXXXXXXXXXXXXXX XXXXXXXXXXXXXX XXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXX An ONVIF Profile S compatible Network camera An ONVIF Profile S compatible VMS/NVR system Access Control System Card reader Number of station registrations in address book Product number Product name Number of station registrations in address book IX-MV Master Station 500 stations IX-DA, IX-DF, IX-DF-PI*1, IX-DF-P*1 Video Door Station Audio Only Door Station 20 stations*2 20 stations*2 IX-BA, IX-SS *1 Card Reader is not included. *2 Only Master Stations can be registered (Max. 20). 41 Contact input Serverless Configuration Achieves Savings in Space and Installation Work, and Lower Costs Internet Typical Systems PoE switch Typical systems require a “separate server” and the attendant effort of installation work and administration. Router Server Control unit Expansion unit Expansion unit The IX System is serverless, which eliminates the risk of system downtime due to server malfunction. PoE switch Router ONVIF-compatible ONVIF-compatible network camera network camera A Guide to Terms ONVIF (Open Network Video Interface Forum) The interface specifications established by ONVIF provide standards that enable exchange of live video and audio as well as control information and the like by surveillance cameras and other network video devices feed, even among products from different manufacturers. INTEGRATED SECURITY & COMMUNICATION SYSTEM VPN connection IX System VMS (Video Management Software [or "System"]) This refers to video management software using an IP network. Servers and cameras of any make can be installed, enabling configuration of systems matched to user needs. NVR (Network Video Recorder) This is a device that records video feed from a network camera over an IP network. Open API This refers to a publicly disclosed set of commands and functions that can be used in programming. It enables control of intercom functioning by user programs, and also makes it possible for user programs to acquire information from intercoms. 42 IP Network Audio - Video Intercom System Master station IX-MV IP Direct Audio and Video Master Station Features Specifications (IX-MV) • Directly connectable to an IP network • 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, push-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Video image adjusting function • Call or communication transferring to another master station • Paging to a group or all stations • Monitoring a single station • Power supply by the PoE Power source Power-over-Ethernet (IEEE 802.3af Class 0) Communication Hands-free/Push-to-talk Handset:Full-duplex/Push-to-talk Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin Wiring Unit dimensions 2C L Relay output L 38 250 Audio door station 59 • Directly connectable to an IP network • Door release output • LED indicator active while calling, talking, and releasing the door • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Power supply by the PoE PoE-enabled switch 2C S SE Polarized Contact Input Specifications (IX-BA) Power source Power-over-Ethernet (IEEE 802.3af Class 0) Communication Open voice hands-free communication Mounting Material Surface-wall mount (directly to wall) Front panel: Fire-retardant resin Main unit: flame resisting PC+ABS resin Unit dimensions IX-BA IX-BA IX-SS 96.8 23 265 129 IP Direct Audio Door Station 42 150 2 45 Wiring IX-BA IX-SS 2C Contact Input IX-SS IP Direct Audio Door Station • Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 Polarized Brown Red Shielded wire Audio Output (to paging amplifier) Orange Yellow 2C Relay Output (the electric lock) 15m 43 CAT5e/6 Green Blue Purple S SE P P NO COM NC 100 m LAN/PoE INTEGRATED SECURITY & COMMUNICATION SYSTEM Features 100 m LAN/PoE 189 162 IX-MV CAT5e/6 PoE-enabled switch IP Direct Audio and Video Door Station Unit dimensions • Directly connectable to an IP network • Door release output • The indicator flash by press the button, talking, door releasing • White light LED to illuminate the visitor automatically at night • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Power supply by the PoE 129 IX-DA 96.8 23 42 IX-DF IX-DF-P,IX-DF-PI Specifications (IX-DA) 265 IX-DA Features 265 Video door station Power source IP Direct Audio and Video Door Station • Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 IX-DA, IX-DF IX-DF-P, IX-DF-PI 150 2 45 Brown Polarized Red Shielded wire Audio Output (to paging amplifier) 2C Green Blue Purple Relay Output (the electric lock) IX-DF-P Orange Yellow S SE 100 m CAT5e/6 PoE-enabled switch P P NO COM NC 15m Image view area IX-DA, IX-DF, IX-DF-P, IX-DF-PI (*)For IX-DF-P, IX-DF-PI (0k) (15k) (-8k) approx.185cm (*190) approx.185cm approx.65cm approx.70cm approx.120cm 150cm approx.70cm approx.115cm (*120) approx.120cm (*125) 150cm 130cm 50cm approx.190cm (*195) 50cm 50cm 15cm INTEGRATED SECURITY & COMMUNICATION SYSTEM Contact Input • Same features as IX-DF • Compatible with HID® ProxPoint® Smart Card Reader • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 * Card reader not included 2 45 Wiring 2C IP Direct Audio and Video Door Station for ProxPoint® Reader 150 LAN/PoE IX-DF Power-over-Ethernet (IEEE 802.3af Class 0) Communication Open voice hands-free communication Camera 1/4-inch color CCD Minimum illumination 5 Lux Surface-wall mount (directly to wall) Mounting Material Front panel: fire-retardant resin Main unit: flame resisting PC+ABS resin 50cm IX-DF-PI IP Direct Audio and Video Door Station for iCLASS® Reader approx. 95 cm • Same features as IX-DF • Compatible with HID® iCLASS® Smart Card Reader • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 * Card reader not included 44 IP Network Audio - Video Intercom System IP Addressable Emergency Stations: Mix and match unlimited Master station Emergency Wall BoxesFeatures (optional) • Light cage with IX-MV beacon / strobe light Direct Audio lettering and •IP “ASSISTANCE” Video Master Station Series Emergency Station • Stainless steel Unit dimensions • Wall mount • Compatible with any IX Series Emergency Station • Stainless steel Wiring • Wall mount • PoE • PoE • PoE • Fixed camera • Lettering and Braille signage • Lettering and Braille signage • Lettering and Braille signage • LED call status indicator • LED call status indicator • LED call status indicator • Dual call buttons • 2 Form C relay outputs 189 162 • Stainless steel • Weather resistant 2C Relay output • Flush mount • Back box included • Dual call buttons IX-MV • 2 Form C relay outputs 100 m • Stainless steel CAT5e/6 • Weather resistant L • Flush mount • Back box included LAN/PoE IS‑WBCA* (can call up to 20 master stations at one time) Specifications (IX-MV) • Directly connectable to an IP network Power source Power-over-Ethernet • 3.5-inch display for operation and video monitoring (IEEE 802.3af Class 0) • A variety of display modes designed for assisting your Communication Hands-free/Push-to-talk Handset:Full-duplex/Push-to-talk operation Monitor 3.5-inch color LCD monitor • Hands-free, push-to-talk or handset audio communication • Direct voice call from master station to another station Mounting Desktop use (with or without desktop stand) or wall-mounting • System settings are possible on the connected PC Material Flame resisting ABS resin • Various setting items for customizing your master station • Video image adjusting function • Call or communication transferring to another master IS‑WBHA* station • Light hood with to a group or all stations • Paging beacon / strobe light IX‑DF‑2RA IX‑SS‑2RA IX‑SS‑RA • Monitoring a single station IP Addressable IP Addressable IP Addressable • “ASSISTANCE” lettering • Power supply by the PoEVideo Emergency Station Audio Emergency Station Audio Emergency Station • Compatible with any IX L 38 59 250 • Light cage with beacon / strobe ligh • “EMERGENCY” lettering • Compatible with any IX Series Emergency Station • Stainless steel • Wall mount • Light hood with • Directly beacon / strobe lightconnectable to an IP network • Door lettering release output • “EMERGENCY” • Compatible withindicator any IX active while calling, talking, and • LED Series Emergency Station releasing the door • Stainless steel • System settings are possible on the connected PC • Wall mount Polarized • 2 Form C relay outputs • Stainless steel PoE-enabled • Weather resistant switch • Flush mount • Back box included Contact Input Specifications (IX-BA) Power source Power-over-Ethernet (IEEE 802.3af Class 0) Communication Open voice hands-free communication Mounting Material Surface-wall mount (directly to wall) Front panel: Fire-retardant resin Main unit: flame resisting PC+ABS resin • Calling up to 20 preprogrammed master stations all Emergency Station Features together Fixed camera provides clear visitor identification (video station) • Power supply by the• PoE System Features Unit dimensions • Scalable system is easy to expand - mix and match an infinite (∞) IX-BA IX-SS number of emergency stations, and master stations! • All‑in‑one communication system to control video entry and access control • Uses new or existing CAT‑5e or CAT‑6 network infrastructure Wiring IX-SS IP Direct Audio Door Station PS‑2420 24V DC, 2A PowerOutput Supply Audio (to paging amplifier) *Power supply required for beacon / strobe light with Wall Box Relay Output 2 wires • Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 265 129 Emergency Towers IX-BA Please contact Aiphone IP Direct Audio Door Station for more details. Contact Input (multicast support recommended) 23 96.8 • Program system functions via Support Tool (recommended) 42 or browser • IP addressable stations provide easy network communication • 24/7 streaming from video emergency station 150 2 45 • ONVIF compliant video output • Integration with Lenel® OnGuard® IX-BA • View third party IP cameras from IX-MV master stations IX-SS 100 m • Forward missed calls automatically CAT5e/6 • Paging with two2C priority levels Brown PoE-enabled switch S • Priority call queueing Polarized Red SE • Transfer door calls to any master station Shielded wire Orange • Standard door release wiring to emergency station or to RY-IP44 for added security P Yellow 2C (the electric lock) 15m 45 S SE LAN/PoE INTEGRATED SECURITY & COMMUNICATION SYSTEM Audio door stationIS‑WBHE* IS‑WBCE* Features 2C • Single call button Green Blue Purple P NO COM NC * Use existing 2-wire LE Series or NE Series Audio Door / Sub Stations!  IX‑1AS 2-Wire Audio Door / Sub Station Network Adaptor • Supports 1 LE Series or NE Series Door / Sub Station Accessories IX‑10AS 2-Wire Audio Door / Sub Station Network Adaptor • Supports up to 10 LE Series or NE Series Door / Sub Stations KAW‑D 30˚ Angle Box for IX‑DA or IX‑BA g P.97 IP Addressable Master Station: Select unlimited (can call up to 500 door stations, emergency stations, or master stations) IX‑MV IP Addressable Video Master Station • 3-1/2" LCD screen • Hands‑free communication with handset for privacy • Wall or desk mount • 500 station address book capacity SBX‑ISDVF SBX‑ISDVFRA EL‑12S RY‑IP44 Surface Mount Box for IX‑DF, IX-DF-P, IX-DF-PI or IX‑SS g P.97 IP Input / Output Relay Adaptor (requires PS-1225) Specifications Power Source PoE (802.3af) Network Interface Hardwired Stations: 10 BASE‑T / 100 BASE‑TX Ethernet (RJ-45) Network Protocols IPv4, IPv6, TCP, UDP, SIP, HTTP, HTTPS, RTSP, RTP, RTCP, IGMP, MLD, SMTP, DHCP, NTP, DNS Bandwidth Usage G.711: 64Kbps x 2 per video call, 64Kbps per monitor H.264: 24Kbps ~ 2,048Kbps Video Stream ONVIF Profile S Communication Hands‑free (full-duplex), push‑to‑talk (simplex), or handset (full-duplex) Door Release Programmable dry contact, 24V AC/ DC, 500mA – use EL‑12S or use RY‑IP44 with 4 multipurpose relays Wire Type CAT‑5e or CAT‑6 Distance Door Station or Emergency Station to Network Node: 100m INTEGRATED SECURITY & COMMUNICATION SYSTEM Electric Door Strike g P.98 Surface Mount Box for IX‑DF‑2RA, IX‑SS‑2RA, or IX‑SS‑RA g P.97 Master Station to Network Node: 100m 46 Security IP Video Intercom System IS IS Series is a network-based IP intercom system that can make centralized security management simple and easy. Ideal for both small and large facilities. Used as IP network system IS Series can be used as a local network security system in a facility, or as an IP network security system that can manage more than one facility from a control center. IP network system image Hardwired network system INTEGRATED SECURITY & COMMUNICATION SYSTEM IS-IPMV The Audio Sub Station is available. You can choose the Audio Sub Station. The Audio Sub Station can be selected from 3 types, a handset type or hands-free type. 47 Hardwired network system Your PC can be used as the Master Station (IS-SOFT). You can use your PC just like the Master Station by installing the IS software. * It may not be available depending on your PC or OS version. IS-RS IS-SS IS-SS-2G With conventional series Panoramic wide angle view and Zoom & PanTilt for higher security To provide effective security, IS series features a wide angle camera that enables you to see an innovative panoramic view! People standing on sides and people of all heights can be easily identified. 170k viewing angle The IS Series features a wide angle camera with PanTilt & Zoom function. Innovative Wide View of Approx. 170k Other Functions Schedule Chime Customize Sounds Forward Unanswered Calls Automatically Transfer Video Calls Emergency Broadcasts Browser Based Set-up Create zones easily to broadcast emergency announcements quickly. Simply use a browser to get on line and set-up, change, or customize the IS systems. Create Unique System Settings Paging Program daily Chime by day, week, month, Create different schedules for holidays, breaks, or after hours. If a master station is not answered, have the calling forwarded to another master station. Hardwired system IP system 20 160 X /site Master Stations IS-MV Local IP system system 20 32 X /site IP Master Stations IS-IPMV Hardwired system X 20 32 IS-IPDV Video Door /site Stations Hardwired system /site IP Door Stations IP system 120 960 X IS-DVF Local IP system system X You can make a paging from the Master Station to other Master Stations, Door Stations, and Room Sub Stations. IP system 20 160 IS-DV Call-ins from a video door station can be transferred to any standard or PC master station on the network for easy identification. IS-RS IS-SS Local IP system system 20 31 X /site Audio Stations /site PC Master Stations Application IS-IPDVF INTEGRATED SECURITY & COMMUNICATION SYSTEM Save system settings, then export and upload them to another system. Load up to 15 Pre-recorded messages or sound source. IS-SOFT The maximum number of each unit connectable to a standard (IP) system differs from the system configuration. * Depending on combinations, the number above may not be applied. 48 Security IP Video Intercom System System Configuration WAN system Site.1 Site.2 IS-IPMV PS24 IS-SOFT IS-IPDV IS-IPMV 100m PS24 100m Hub IS-SOFT PS24 Hub 100m Router Router Internet Router Site.4 Hub Hardwired system INTEGRATED SECURITY & COMMUNICATION SYSTEM IS-IPC Hardwired system IS-PU 10m Hardwired system IS-IPC IS-CCU IS-PU IS-CCU IS-PU 150m 300m IS-MV IS-DV IS-MV IS-DV IS-DV 300m IS-MV 300m IS-PU 300m IS-RS IS-MV 49 100m IS-DV 300m IS-SS IS-RS IS-SS Site.3 WAN system LAN system Hardwired system IS-IPMV PS24 IS-IPMV PS24 IS-SOFT IS-IPDV Site PS24 x Max.32 Hub Router Site.5 Router Hub Site.. 100m 100m IS-IPC IS-PU IS-CCU IS-IPMV IS-IPDV PS24 IS-PU IS-MV IS-DV IS-MV IS-DV IS-RS PS24 INTEGRATED SECURITY & COMMUNICATION SYSTEM Hardwired system Router IS-SS PS24 : PS-2420 IS-PU : IS-PU 50 Security IP Video Intercom System System Configuration Site system WAN system Internet LAN system Hardwired system Router Site Hub 100m 100m Hardwired system 100m PS24 100m PS24 IS-IPC INTEGRATED SECURITY & COMMUNICATION SYSTEM 10m IS-IPMV IS-IPDV IP master station IP door station IS-PU IS-CCU ~Max.32 IS-PU 150m 300m Hardwired system x Max.8 IS-MV IS-MV ~Max.32 ~Max.31 Up to 32 IP units (including the IP control unit(s)) can be connected in a site. 300m Master station 300m PC IP master station IS-DV IS-RS 300m IS-SOFT IS-DV ~Max.160 Video door station ~Max.160 Audio station ~Max.960 300m IS-SS PS24 : PS-2420 IS-PU : IS-PU 51 System Configuration Hardwired system Timer IS-MV IS-CCU Max.4 or IS-PU or or or Monitor CD player IS-DV IS-DVF IS-SS IS-SS-2G IS-RS Max.4 PA amplifier PA speaker IS-RCU Max.4 IS-SCU Max.2 PA amplifier PA amplifier IS-PU PA speaker IS-PU IS-RS or IS-MV IS-SS Max.8 IS-DV or IS-DVF Max.30 or IS-SS or IS-SS-2G Max.8 PT 8d speaker Call button Strobe light Monitor Audio recorder EL-12S PT : AC transfarmer IS-PU : IS-PU Maximum number of each unit connectable to a hardwired system Category Model name Type IS-CCU Central control unit IS-SCU Add-on control unit Control unit IS-RCU Room sub control unit IS-MV Color monitor master station Master station Vandal resistant video door station IS-DV (surface-mount) Sub station IS-DVF Vandal resistant video door station (flush-mount) IS-SS(-2G) Vandal resistant door station (flush-mount) IS-RS Room sub station*1 Max. number 1 2 4 20 IS-RS INTEGRATED SECURITY & COMMUNICATION SYSTEM or PA speaker 20 120 *1: You can use vandal resistant door stations (lS-SS or lS-SS-2G) instead of room sub stations (lS-RS). 52 Security IP Video Intercom System IP Master station IS-IPMV IP master station w/Wide and Zoom & PanTilt color monitor Features Specifications (IS-IPMV) • Directly connectable to an IP network • 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, press-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Zoom/wide and pan & tilt video monitoring function • Video image adjusting function • Call or communication transferring to another master station • Paging or chime paging to the registered zones and / or stations • Monitoring a single station or scan-monitoring up to 20 pre-programmed stations • Either power supply unit (PS-2420) or PoE Power source Current consumption PS-2420, or PoE Max. 65mA (PoE) Max. 130mA (when power supply unit is used) Communication Handset: simultaneous communication (When press-to-talk (PTT) is not set) Hands-free: auto-voice actuation or Press-to-talk (PTT) Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin Wiring Unit dimensions IS-IPMV A+ A2 Audio output 2C 15m DC24V 189 162 LAN/PoE 100m 38 IP Video door station 59 + - Features Unit dimensions 265 Wide and Zoom & PanTilt Vandal resistant IP video door station, surface mount 105 Switch (HUB) + - Polarized Specifications (IS-IPDV, IS-IPDVF) Power source Current consumption PS-2420, or PoE Max. 85mA (PoE) Max. 160mA (when power supply unit is used) Communication Open voice hands-free communication Camera 1/4-inch color CMOS Minimum illumination 5 Lux Camera angle Wide: approx. 170k (horizontal) IS-IPDV: Surface-wall mount Mounting (directly to wall) IS-IPDVF: Flush-mount Material Front panel: aluminum die-cast (IS-IPDV) stainless steel(IS-IPDVF) Main unit: flame resisting PC+ABS resin Image view area Refer to the descriptions for the image view area. m P.10 28 150 45 Wiring IS-IPDV IS-IPDVF PT CAT5e/6 Switch (HUB) NC COM NO DC24V AC transformer Wide and Zoom & PanTilt Vandal resistant IP video door station flush mount 100m LAN/PoE Electric door lock (N/O or N/C) + - + - Polarized Power supply PS-2420 15m 10m PT 53 Power supply PS-2420S / UL Handset Connection • Directly connectable to an IP network • Approx. 170k range wide view video camera • Door release output • Directory card with backlight • White light LED to illuminate the visitor automatically at night • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Remote site calling and communicating capability • Either power supply unit (PS-2420) or PoE IS-IPDV CAT5e/6 15m Handset 215 INTEGRATED SECURITY & COMMUNICATION SYSTEM 250 RJ45 : AC transformer PC application IS-SOFT PC application PC monitor Features System requirements • PC software with full master station functions • 7 languages (English, French, Spanish, German, Dutch, Italian & Japanese) are selectable for displaying windows • Various settings are possible from 9 setting windows • Play window for searching for and playing back recorded files • Up to 24 speed dials are available • Records video and audio from video door stations • A still picture or video of visitor can be recorded • Either headset (not included) or handset (not included) can be used for communication • Hands-free or press-to-talk communication is possible with a headset OS Video & Audio communication with entrance side by PC Windows XP Home/Professional (SP3)/32-bit version, Windows Vista Ultimate/Home/Business/Enterprise (SP2)/ 32-bit version/64-bit version Windows 7 Home Premium/ Professional/Enterprise/Ultimate/32-bit version/64-bit version Windows 8/Pro/Enterprise/32-bit version/64-bit version PC system Processor: 2 GHz or faster requirements System memory (RAM): 1 GB RAM or more Hard disk: 10 MB or more (additional space is needed for recording) Sound card: 8-bit full duplex, Direct Sound compatible Display: 800 x 600 or higher 1024 x 768 or higher 1920 x 1200 or higher Run-time: Microsoft ®.NET Framework 4.0 or later Network: 10BASE-T/100BASE-TX Ethernet Protocol TCP/IPv4, UDP/IPv4, TCP/IPv6, UDP/IPv6, SIP, Others Network bandwidth 320 k to 8 Mbps Wide and Zoom & PanTilt control from PC Wide and Zoom PanTilt on Zoom mode WIDE IMAGE Talk button VISITOR ZOOM IMAGE Wide and Zoom & PanTilt button Door Station Unlock the door after verifying visitor identity Room to room communication with master station Unlock Call button IP Control unit IS-IPC IP control unit Unit dimensions Features Specifications (IS-IPC) • Configures a standard (IP) system connecting with an IP network • Connectable with either a central control unit (ISCCU) or room sub control unit (IS-RCU) • System settings are possible on the connected PC • Chime and transfer schedule can be set • System setting data can be downloaded or uploaded • Time correction function synchronized with a PC or NTP server • Daylight saving time is available • Either rack-mounting (into 19-inch rack) or wallmounting is possible Power source 48V DC (supplied from IS-PU) Current consumption Max. 105mA Talk channels • 2 talk & 2 constrained video Video channels, channels,1 chime, other channels Central control unit Room sub control unit LAN Mounting rack-mount Material Max. 1 Ethernet (10 BASE-T, 100 BASE-TX) (19-inch, 2U rack) or wall-mount Steel plate Wiring PBX/CO (North America only) 425 Switch/hub 10BASE-T 100BASE-TX IS-CCU IS-RCU CO 280 TELEPHONE IP1 IP2 100m LAN IP3 INTEGRATED SECURITY & COMMUNICATION SYSTEM Door release button DC48V ETHERNET IS-CCU IS-RCU 10m IP1 IP2 IP3 10m 10m CAT5e/6 (x3) 85 CAT5e/6 (x2) or 480 IS-RCU IS-CCU IS-PU 54 Security IP Video Intercom System Master station IS-MV Master station w/Wide and Zoom & PanTilt color monitor Features Specifications (IS-MV) • 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, press-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Zoom/wide and pan & tilt video monitoring function • Video image adjusting function • Call or communication transferring to another master station • Paging or chime paging to the registered zones and/or stations • Monitoring a single station or scan-monitoring up to 20 pre-programmed stations • Remote site calling and communicating capability (required IS-IPC) Power source Supplied from the central control unit or add-on control unit Communication Handset: simultaneous communication (When press-to-talk (PTT) is not set) Hands-free: auto-voice actuation or Press-to-talk (PTT) Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin Wiring Unit dimensions Recorder, etc. Monitor, etc. 300m IS-MV CAT5e/6 M IS-CCU 189 162 15m or V V A A IS-SCU 59 300m Features • Approx. 170k range wide view video camera • Door release output • Directory card with backlight • White light LED to illuminate the visitor automatically at night • Calling up to 20 pre-programmed master stations all together • Remote site calling and communicating capability (required IS-IPC) Unit dimensions Wide and Zoom & PanTilt Vandal resistant video door station, surface mount 265 IS-DV 215 INTEGRATED SECURITY & COMMUNICATION SYSTEM Video door station 105 Specifications (IS-DV, IS-DVF) Power source Supplied from the central control unit or add-on control unit Communication Open voice hands-free communication Camera 1/4-inch color CMOS Minimum illumination 5 Lux Camera angle Wide: approx. 170k (horizontal) IS-DV: Surface-wall mount Mounting (directly to wall) IS-DVF: Flush-mount Material Front panel: aluminum die-cast (IS-DV) stainless steel(IS-DVF) Main unit: flame resisting PC+ABS resin Image view area Refer to the descriptions for the image view area. m P.10 28 150 45 Wiring IS-DV IS-DVF Electric door lock (N/O or N/C) PT IS-DVF Wide and Zoom & PanTilt Vandal resistant video door station flush mount 300m D AC transformer 55 CAT5e/6 15m 38 250 V ID E O O UTPUT A U D IO O UTPUT NC or IS-CCU COM NO 10m IS-SCU Audio station Features Unit dimensions 265 199 • Calling up to 20 pre-programmed master stations all together • Remote site calling and communicating capability (required IS-IPC) • Electric door strike can be connected. • External speaker can be connected (IS-RS only) • Option input and option output (IS-RS and IS-SS-2G) 40 116.5 64 120 2 150 45 120 IS-RS Room sub station 47 Specifications (IS-RS) Power source Supplied from the central control unit, add-on control unit or room sub control unit Specifications (IS-SS, IS-SS-2G) Communication Handset: simultaneous communication Hands-free: auto-voice actuation or Press-to-talk (PTT) Surface-wall mount (directly to wall or electrical box) Power source Supplied from the central control unit, add-on control unit or room sub control unit Communication Mounting Open voice hands-free communication Flush-mount Material Front panel: stainless steel Main unit: flame resisting PC+ABC resin Mounting Material Flame resisting ABS resin Wiring IS-SS Electric door lock (N/O or N/C) Vandal resistant door station, flush mount AC transformer PT 300m NO IS-RS 15m External speaker Vandal resistant door station, flush mount 2-gang mounting Control unit IS-CCU Central control unit IS-SCU Add-on control unit Contact input (Sensor, etc.) Contact output (Electric door strike, strobe light, etc.) C SP SP 150m IS-CCU or IS-SCU/RCU S SE NO COM Features (IS-CCU) Features (IS-RCU) • Configures a local system with up to 2 add-on control units, 4 room sub control units, in total 20 master stations, 120 sub stations and 28 PA outputs • 4 PA outputs, 2 chime inputs, 2 video outputs • System settings are possible on the connected PC • Up to 3 M Bytes of audio files can be uploaded for sound source • Chime and transfer schedule can be set • 3 triggered actions selectable for contact input • 5 trigger conditions selectable for contact output • System setting data can be downloaded or uploaded • Time correction function synchronized with a PC or NTP server • Daylight saving time is available • Either rack-mounting (into 19-inch rack) or wallmounting is possible • Connectable with up to 30 sub stations • Connectable with either an IP control unit (IS-IPC) or central control unit (IS-CCU) • 4 PA outputs • 4 trigger conditions selectable for contact output • Either rack-mounting (into 19-inch rack) or wall-mounting is possible Unit dimensions (IS-CCU, IS-SCU, IS-RCU) IS-CCU / IS-SCU / IS-RCU 425 INTEGRATED SECURITY & COMMUNICATION SYSTEM or IS-SS-2G IS-CCU or IS-SCU/RCU NC COM 280 IS-SS D 10m IS-RCU Room sub control unit • Adds up to 8 master stations and 8 sub stations in a local system • 4 PA outputs • 4 trigger conditions selectable for contact output • Either rack-mounting (into 19-inch rack) or wall-mounting is possible 85 Features (IS-SCU) 480 (IS-CCU) 56 Security IP Video Intercom System Specifications (IS-CCU) Power source Current consumption Talk channels • Video channels Master station(s) Video door station(s) Audio door station(s) Room sub station(s) Add-on control unit Room sub control unit IP control unit Video output Mounting 48V DC (supplied from the power supply unit) Wiring IS-CCU Contact output (Electric door lock, strobe light, etc.) PA output (600d) Contact input PA amplifter Sensor, etc. External sound source such as CD player, etc. Monitor 1, video recorder 1 Max. 0.8A Local system: 2 talk & 2 video channels, 1 chime PC for setting the system Monitor 2, video recorder 2 AC transformer P T Max. 4 P1 P2 P3 P4 L1 L2 PA OUTPUT (600d) Max. 4 CAT5e/6 L4 L5 L6 L7 L8 S1 E S2 E S3 E B1 S4 E CONTACT INPUT B2 V1 V2 IS-SCU 2C X 1 3C X 1 4C X 1 M1 M3 D1 D3 1MX 1 1MX 3 2MX 2 IP 1 1C X 2 2C X 2 3C X 2 4C X 2 M2 M4 D2 D4 1MX 2 2MX 1 2MX 3 IP 2 CAT5e/6 ETHERNET IS-IPC 1C X 1 CAT5e/6 LA N VIDEO OUTPUT CHIME INPUT (600d) VIDEO/AUDIO DOOR/SUB STATION MASTER STATION IS-RCU Max. 2 Max. 4 Max. 1 NTSC BNC (Video channel 1,2) L3 CONTACT OUTPUT (AC/DC24V 0.5A) DC48V IP 3 CAT5e/6 CAT5e/6 CAT5e/6 (x3) Rack-mount (19-inch, 2U rack) or wall-mount CAT5e/6 (x3) or * The system setting tool is compliant with Windows XP, Windows VISTA and Windows 7. IS-RCU Specifications (IS-SCU) INTEGRATED SECURITY & COMMUNICATION SYSTEM Power source 48V DC (supplied from the power supply unit) Current consumption Talk channels • Video channels Master station(s) Video door station(s) Audio door station(s) Room sub station(s) Video output Max. 1.2A Local system: 2 talk & 2 video channels, 1 chime Max. 8 Mounting IS-SCU IS-MV IS-SCU IS-RS/IS-SS(-2G) IS-DV/IS-DVF PA output (600d) IS-IPC Contact output (Electric door lock, strobe light, etc.) PA amplifter Monitor 1, video recorder 1 Monitor 2, video recorder 2 BNC connector AC transformer BNC connector PT BNC conne ctor Max. 8 P1 NTSC BNC (Video channel 1,2) Rack-mount (19-inch, 2U rack) or wall-mount P2 P3 P4 L1 PA OUTPUT (600d) IS-PU L2 L3 L4 V1 V2 VIDEO OUTPUT CONTACT OUTPUT (AC/DC24V 0.5A) MASTER STATION BNC conne ctor VIDEO/AUDIO DOOR/SUB STATION IS-CCU M1 M3 M5 M7 D1 D3 D5 D7 MX 1 M2 M4 M6 M8 D2 D4 D6 D8 MX 2 MX 3 DC48V Specifications (IS-RCU) Power source 48V DC (supplied from the power supply unit) CAT5e/6 CAT5e/6 CAT5e/6 CAT5e/6 (x3) Current consumption Max. 1.8A Talk channels Local system: 2 talk channels, 1 chime or Audio door station(s) Room sub station(s) Max. 30 Mounting Rack-mount (19-inch, 2U rack) or wall-mount IS-MV IS-CCU IS-DV/IS-DVF IS-RS/IS-SS(-2G) IS-RCU IS-PU Contact output (Electric door lock, strobe light, etc.) PA output (600d) PA amplifter AC transformer P1 P2 P3 P4 PT L1 PA OUTPUT (600d) L2 L3 L4 CONTACT OUTPUT (AC/DC24V 0.5A) IS-CCU/ IS-IPC AUDIO DOOR/SUB STATION C1 C3 C5 C7 C9 C 11 C 13 C 15 C 17 C 19 C 21 C 23 C 25 C 27 C 29 C X 1/IP 1 C2 C4 C6 C8 C 10 C 12 C 14 C 16 C 18 C 20 C 22 C 24 C 26 C 28 C 30 C X 2/IP 2 CAT5e/6 CAT5e/6 DC48V CAT5e/6 (x2) CAT5e/6 (x2) or IS-RS IS-SS(-2G) or IS-IPC IS-CCU IS-PU 57 Power supply Unit dimensions Specifications (PS-2420) Input voltage & Capacity PS-2420S 52 90 100-240V AC, 50/60Hz 60W/100-125VA 24V DC, 2A PS-2420 167 Output voltage Features Unit dimensions • Either rack-mounting (into 19-inch rack) or wall-mounting is possible by using the optional IS-RACK Power source AC 100 - 240V, 50/60Hz. Power consumption 120W IS-PU Output voltage Output current Mounting Power supply unit Material 265 IS-PU Specifications DC 48V 2.1A Wall-mount or rack-mount (IS-RACK) Steel plate 130 Item Features Video Door Station Audio Station Master Station Hands-free ✓ ✓ - - Handset - ✓ Talk transfer - - Video identification at door call - - Answering to door call - - Door release (contact output) - - Call forwarding on door call - - Absence transfer on door call - - Zone page to door station - - Direct Voice call and talk-back - - Monitor of door camera image / audio - - ✓ ✓ ✓ ✓ Zone paging - - Zone chime of external sound source - - Zone chime of internal sound source - - ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ - - ✓ Press-to-talk Answering to master call Answering to PC master call E-mail at set trigger (small number of addresses) Video output - IP Video Door Station IP Master Station ✓ PC application - ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ - - - - - - ✓ ✓ - ✓ ✓ - ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ INTEGRATED SECURITY & COMMUNICATION SYSTEM Functional Specification 58 Integratable Audio & Video Security MASTER 8 DOOR 120 AX Central exchange unit Master station AX-084C Central exchange unit, 4 masters and 8 doors AX-8MV 8-call color monitor master station AX-248C (Photo) AX-8M Central exchange unit, 8 masters and 24 doors 8-call audio master station AX-8MV-W (white) AX-320C Add-on exchange unit, 32 doors INTEGRATED SECURITY & COMMUNICATION SYSTEM AX-16SW 16-call add-on selector Power supply PS-2420 AX-8MV, AX-16SW Features l Up to 120 video entrance stations and 8 master stations l All wired on CAT5e, homerun cabling l Total hands-free, auto-voice actuation, communication or Press-to-talk operataion l Two talk channels and two video channels. l Communication privacy l Masters available with 3.5-inch color TFT LCD l Selective door release l Master-to-master selective calling and All Call l Standard or Priority call levels from door stations l Scan monitoring: Hands-free audio/visual monitoring l Video output from CEU and AX-8MV l Integrate with CCTV, Access control etc. l PC interface for programming and event logging l Rack or wall mountable CEU l Compatible with IE Series door stations l Optional features: headset, footswitch, and PC remote control m P.100 Communication network AX-DV AX-8MV AX-8MV AX-DVF Video signal PC programming AX-DM Monitor Calling & communication (w/video from door) Door release 59 Door station Lineup EL-12S AX-DV Color video door station surface mount Electric door strike m P.98 AX-DM AX-DVF Audio door station Mullion type Color video door station flush mount AC-10S Access control keypad, surface mount m P.95 IF-DA Audio door station AX-DV-P AX-DVF-P AC-10F Color video door station w/space for embed proximity reader flush mount Access control keypad, flush mount m P.95 IE-JA Audio door station System Integration Cabling 300m Video signal 300m CAT5e AX-8MV Security Integration Software AX System System log AX-8MV Remote door release AX-DV AX-084C Switch camera PC Video signal CCTV System AX-084C VCR Camera Monitor AX-8MV AX-DVF-P CAT5e CAT5e CAT5e Calling & Communication with video Door release AX-DVF PS24 PS24 Door release history CAT5e Remote door release Card ID Access Control System AX-DM Monitor RS232C Door release AX-DV Access Control System PC INTEGRATED SECURITY & COMMUNICATION SYSTEM Color video door station w/space for embed proximity reader surface mount Camera CCTV Switcher Monitor VCR 60 Integratable Audio & Video Security Wiring 300m 300m AX-8MV Cat5e AX-DV Cat5e M 2 AX-248C AX-DVF M 2 2 2 AX-DM Door #1 AX-DV Door #2 AX-DVF INTEGRATED SECURITY & COMMUNICATION SYSTEM 61 N N AX-8M Cat5e Cat5e M 2 Master #1 AX-8MV Cat5e RJ-45 EL-12S Cat5e AX-8MV Cat5e Cat5e Brown Red Yellow Orange Green Blue Cat5e RJ-45 H AX-248C PC Master #2 AX-8MV RJ-45 RJ-45 H EL-12S Door #24 AX-DM Red Brown 3(White green) 6(Green) 7(White brown) 8(Brown) 1 2 4 5 N N Cat5e Cat5e Master #8 AX-8M Cat5e EL-12S RJ-45 H N : PS-2420 H : AC transformer Mounting locations Master station Video door station Install the video master station in a place where the screen is not exposed to direct sunlight. Do not install a video door station in any of the following locations where lighting or the ambient environment could impact the display on the video master station due to the characteristics of the door station's camera. 1. Locations subject to direct sunlight 2. Under street lights or door lights 3. Other locations subject to strong lighting conditions Video + Video IER-2 Foot switch Components AX-DV AX-8MV (AX-8M audio only) AX-16SW Number of master stations Number of add-on selectors per master 1~8 up to 4 9 ~ 24 AX-DVF AX-DM Number of door stations AX-084C or AX-248C AX-320C Number of central exchange unit Number of add-on exchange units AX-084C AX-248C - 1 - - up to 8 1 - 1 - 25 ~ 40 up to 4 2 1 - 1 41 ~ 56 up to 8 3 - 1 1 57 ~ 72 up to 4 4 1 - 2 73 ~ 88 up to 8 5 - 1 2 89 ~ 104 up to 4 6 1 - 3 105 ~ 120 up to 8 7 - 1 3 NOTE: Use the AX-248C for systems with more than 4 master stations (may effect the required quantity of AX-320C). 2 pcs of power supplies are required for video system. Image view area Unit dimension AX-8MV(-W) • AX-DV, AX-DVF AX-DV-P, AX-DVF-P AX-8M 185cm ★ 175 175 ★ 50cm 120cm ★ 150cm 95cm ★ 50cm 194 63 AX-16SW 63 194 AX-320C AX-084C, AX-248C 88 85 Calling 63 AX-DV-P Communication AX-DVF 245 195 AX-DV 100 Power source Power supply Current consumption 246 86 25 100 AX-DVF-P 25 Video monitor Scaning lines Night viewing 146 2 45 130 160 295 Door release contact Outside video output IF-DA AX-DM 98 1-gang Wiring Wiring distance 28 IE-JA 146 22.5 115 43 24V DC, 2A (Two Power supplies required per video system) PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5-inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300 m (CAT5e) CEU to master: 300 m (CAT5e) 2-gang 2 45 116 approximate Specifications 420 426 88 85 175 420 426 ★ INTEGRATED SECURITY & COMMUNICATION SYSTEM 65cm 10 62 AUDIO ENTRY SECURITY Audio based security intercoms for those who want a simple security solution. DB Hands-Free SYSTEM Hands-Free Communication in Any Place. 2-Wire System for Simple Installation. AUDIO ENTRY SECURITY Lineup Hands-free Two-Wire Electric Lock Door Phone Two-Wire Electric Lock Door Phone DB-1MD C-123L/A DA-1AS & DA-4DS P64 P65 Chime Tone Intercom P67 P68 Chime Tone Intercom IE-1AD(U) P69 Chime Tone Intercom IE-1GD(U) P70 63 Chime Tone Intercom Chime Tone Intercom IE-2A2DU P71 IE-8MD P72 P73 Hands-free Two-Wire Electric Lock Door Phone DOOR ROOM 5 DB-1MD 1 Request to exit/entry button Lineup Kit box (DBS-1AK) 2 2 4 4 2 Polarized 4 4 2 PT DB-1SD PT DA-1DS Door station, silver DB-1MD Master station 2 Sub master station EL-12S PT DB-1SD DB-1SD AC-10S Electric door strike m P.98 DB-1SD Access control keypad, surface mount m P.95 2 IER-2 AC-10F Call extension m P.101 Access control keypad, flush mount m P.95 IER-2 Call extension Kit box DBS-1AK PT : AC transformer 16VAC1500/5 m P.99 Features Wiring 100m / 1.0mma 310m / 1.0mma 2 M DA-1DS DB-1MD 2 P 4 DB-1SD P 4 DB-1SD P 2 2 4 DB-1SD P EL-12S L L B1 B2 B3 B4 D F D E DB-1SD 16VAC1500/5 2 2 ~ ~ 16VAC1500/5 IN B1 B2 B3 B4 OUT B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 IN B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 ~ ~ ~ ~ ~ ~ ~ ~ 16VAC1500/5 Option devices (IER-2 etc..) DB-1SD DB-1SD Option lead wires Press "call" button to ring inside station (s). Unit dimensions 100 DB-1MD/1SD 80 22 27 Door release Option contact (AC/DC) 185 Wiring 175 16VAC1500/5 P : Polarized Specifications (DB-1MD, 1SD) Power source AC transformer Communication DA-1DS DB-1SD P 2 16VAC1500/5 16VAC1500/5 DB-1MD M 4 155m / 1.0mma Communication network DB-1SD Door station mounting plate Wiring distance 16V AC 16VAC1500/5 Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. EL-12S or others (More than (AC) 70d, AC 9.5 ~ 20V) Voltage Max. : 24V, Min. : 1V Current Max. : 1.6A, Min. : 10mA 2 wires, throughout AC trans - Master - Door - Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma) AUDIO ENTRY SECURITY l Door release wired from door station, without additional transformer l Two-wire system including door release l Total hands-free communication, auto-voice actuation l Press-to-talk operation available l Up to 5 inside stations l All call for internal communication l User-optional function button l Call tone MUTE with indicator l Call extension sounder l Directory backlighting l Continuous chime tone (approx. 4 seconds) DA-1DS DAW-P DA-1DS DB-1MD 16VAC1500/5 64 Hands-free Two-Wire Electric Lock Door Phone ENTRANCE TENANT 4 DA-4DS with DB-1MD 1 Entrance station Tenant station Tenant 1 2 2 2 DA-4DS 2 4-call door station PT IER-2 DB-1MD Call extension Master station 2 Tenant 2 2 DB-1MD PT DA-2DS 2-call door station DA-4DG 2 4-call door station Tenant 3 2 DB-1MD PT 2 Tenant 4 2 PT : AC transformer 16VAC1500/5 DB-1MD PT m P.99 Communication network Wiring 100m / 1.0mma 310m / 1.0mma DB-1SD DB-1SD DB-1SD Tenant 1 DB-1SD 2 DB-1MD AUDIO ENTRY SECURITY P 4 DB-1SD 2 M 2 DB-1MD #2 DB-1SD P 1 D E M DB-1SD 2 155m / 16VAC1500/5 16VAC1500/5 1.0mma Tenant 2 Tenant 3 Tenant 4 16VAC1500/5 D E ~ ~ 16VAC1500/5 IN B1 B2 B3 B4 OUT B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 IN B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 ~ ~ ~ ~ ~ ~ ~ ~ 16VAC1500/5 Option devices (IER-2 etc..) 16VAC1500/5 Option connectors. DB-1MD #4 65 4 P 2 2 B1 B2 B3 B4 L L DB-1MD #3 4 Tenant 1 EL-12S DA-4DS DB-1SD P 2 P DB-1MD #1 DA-4DS 4 2 D E Tenant 2 3 D E Tenant 3 4 D E Tenant 4 P : Polarized Lineup 4 4 4 4 EL-12S 2 2 DB-1SD Sub master station PT Electric door strike m P.98 2 2 DB-1SD DB-1SD DB-1SD Call extension m P.98 4 2 2 Same as the above 2 Same as the above PT 4 Access control keypad, surface mount m P.95 PT IER-2 4 AC-10S AC-10F Access control keypad, flush mount m P.95 4 2 PT 4 DAW-P 4 2 Door station mounting plate Same as the above 2 PT Features Specifications (DA-4DS, G) l Door release wired from door station, without additional transformer l Two-wire system including door release l Total hands-free communication, auto-voice actuation l Press-to-talk operation available l Up to 5 inside stations in each tenant l All call for internal communication l User-optional function button l Call tone MUTE with indicator l Call extension sounder l Directory backlighting l Continuous chime tone (approx. 4 seconds) Power source Power supply Communication Wiring Wiring DB-1MD/1SD 80 22 185 175 Power source AC transformer Communication Door release Option contact (AC/DC) DA-2DS DA-4DS,G 100 Specifications (DB-1MD, 1SD) 27 Wiring distance 16V AC 16VAC1500/5 Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. EL-12S or others (More than (AC) 70d, AC 9.5 ~ 20V) Voltage Max. : 24V, Min. : 1V Current Max. : 1.6A, Min. : 10mA 2 wires, throughout AC trans - Master - Door - Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma) AUDIO ENTRY SECURITY Unit dimensions 16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door - Door rlse. 66 Two-Wire Electric Lock Door Phone DOOR ROOM 1 DA-1ASK 1 Boxed set Lineup DA-1ASK EL-12S AC-10S Electric door strike m P.98 Kit box (silver color) Access control keypad, surface mount m P.95 AC-10F Access control keypad, flush mount m P.95 DA-1MD DA-1DS Master station Door station silver panel DAW-P Door station mounting plate (83.5mm) PT : AC transformer 16VAC1500/5 m P.99 Features l Two-wire system including door release l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder Wiring 310m / 1.0mma 155m / 1.0mma DA-1MD Door station M 2 2 2 P Communication network 16VAC1500/5 (1) EL-12S AUDIO ENTRY SECURITY Door station DA-1MD DAR-1 (2) ~ ~ D E D E 16VAC1500/5 16VAC1500/5 S SE SW SW M Hold down gCALLh button to ring inside station. Unit dimensions DA-1MD Door station 22 200 175 100 89 61 S SE (3) l Place 16VAC1500/5 inside electrical enclosure and connect to breaker, less than 16A. l Do not use 16VAC1500/5 for any other equipment. l Terminals SW, SW; Dry-closure contact 18V AC, 40mA to connect user-optional function (Gate, Light, Garage, Proximity Access Control, etc.) (1) External device Relay/Controller (2) Door release (16V AC, 20d or more) (3) User-optional function (18V AC, 40mA) Specifications (DA-1AS, G) Power source Power supply Communication Wiring Wiring distance 67 L L 16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door- Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DA-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) Two-Wire Electric Lock Door Phone ENTRANCE TENANT 4 DA-4DS 1 Entrance station Lineup Tenant station EL-12S AC-10S Electric door strike m P.98 DA-2DS Access control keypad, surface mount m P.95 DA-4DS 2-call door station 4-call door station AC-10F Access control keypad, flush mount m P.95 DA-1MD Master station AC transformer 16VAC1500/5 DA-4DG DAW-P Door station mounting plate (83.5mm) m P.103 4-call door station Features l Two-wire system l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder Wiring 310m / 1.0mma 155m / 1.0mma DA-4DS DA-4DG M 2 DA-1MD 2 DA-1MD DA-1MD DA-1MD DA-1MD DA-4DS, DA-4DG EL-12S 1 D E 2 D E 3 D E 4 D E P 2 P P ~ ~ AC15 ~ ~ AC15 16VAC1500/5 D E P P D E P 22 61 (3) DA-1MD S SE DA-1MD DA-1MD (1) DA-1MD DA-4DS, DA-4DG 2x2 200 175 D E SW SW DA-1MD 89 100 ~ ~ AC15 Unit dimensions DA-2DS DA-4DS,G DA-1MD 2 2 AC15 (1) 2x2 2x2 2x2 AUDIO ENTRY SECURITY Electronic tone. Direct select ring. ~ ~ D E DA-1MD 2 P L L (2) M 2 P Communication network DA-1MD 16VAC1500/5 (1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door release : EL-12S or 16V AC, 20 d or more (3) When a single common power supply is used Specifications (DA-4DS, G) Power source Power supply Communication Wiring Wiring distance 16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door - Door rlse. 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DA-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) 68 Chime Tone Intercom DOOR ROOM 1 C-123L/A 1 Door station Master station Lineup AC-10S Access control keypad, surface mount m P.95 C-D Door station *Not available separately C-ML/A Master station AC-10F Access control keypad, flush mount m P.95 Boxed set C-123L/A Chime-Com boxed set Power supply 6VDC2500/1 or Batteries EL-12S Electric door strike m P.98 m P.99 Features Wiring l Open voice door answering with door release control l Adjustable communication volume l Automatically turns off l Battery or DC power supply 115m / 0.8mma C-ML/A C-D 2 NP M Communication network AUDIO ENTRY SECURITY EL-12S W L L C-ML/A C-D H H : AC transformer W : 6VDC2500/1 M Specifications (C-123L/A) Power source Power supply Communication Unit dimensions C-D C-ML/A Wiring 88 83.5 190 120 83.5 Wiring distance 29 130 69 1 E + – 1 E 44 6VDC2500/1 6VDC2500/1 or Batteries gCh(SUM-2) x 4 pcs. Door calls in w/2-tone chime, not adjustable. Press TALK button to reply, release to listen. Power automatically shuts off circuit. 2 parallel wires to door, non-polarized (+ 2 for EL-12S). Master to door 75m(0.65mma) 115m(0.8mma) Chime Tone Intercom 1 IE-1AD(U) DOOR ROOM 1 Door station Master station Lineup EL-12S Electric door strike m P.98 IF-DA AC-10S Access control keypad, surface mount m P.95 Door station m P.71 IER-2 Call extension m P.98 Power supply AC-10F Access control keypad, flush mount m P.95 IE-1AD(U) Master station 12~24V DC power supply 12~16V AC transformer Features Wiring l Chime tone intercom for 2 locations l Door release button l AC or DC power source 360m / 1.0mma IE-1AD(U) IF-DA IER-2 2 NP 2 M 1 2 Communication network EL-12S IF-DA 1 2 L L + – WH 1 E IER-2 l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer WH : White(2) M Specifications (IE-1AD(U)) Power source Power supply Communication Unit dimensions IF-DA 130 IE-1AD(U) 98 Door release Wiring 210 83.5 83.5 Wiring distance 12~16V AC, 180mA 12~24V DC, 160mA AC transformer (for IE & EL-12S), PS-1225. Door calls in w/4-tone chime, adjustable. Pick up handset to reply. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized (+2 for EL-12S) IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma) AUDIO ENTRY SECURITY H IE-1AD(U) 2 28 80 58 70 Chime Tone Intercom 3 IE-1GD(U) DOOR ROOM 1 Door station Master station Sub station Lineup EL-12S AC-10S Electric door strike m P.98 IE-JA Access control keypad, surface mount m P.95 Door station m P.71 IER-2 AC-10F Call extension m P.98 IE-1GD(U) Master station Power supply Access control keypad, flush mount m P.95 IEH-1CD Sub master station 12~24V DC power supply or 12~16V AC transformer Features Wiring l 3-station chime tone intercom with one door l Door release button l All call type room calling l Chime tone cutout at sub station l AC or DC power source 360m / 1.0mma 190m / 1.0mma IE-1GD(U) 2 M Communication network AUDIO ENTRY SECURITY 1 2 IEH-1CD IE-JA IEH-1CD 6 6 IER-2 2 2 D1 E1 IER-2 IE-1GD(U) EL-12S M H T R C E T R C E T R C E L L L L L L 1 E + – IEH-1CD l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer All Call type calling with pretone & voice Specifications (IE-1GD(U)) Unit dimensions Power source IE-1GD(U) IEH-1CD IE-JA Power supply Communication 210 83.5 83.5 115 116 Door release Wiring 10 100 71 IEH-1CD IE-JA 61 Wiring distance 12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V, 550mA (for both IE & EL-12S), PS-1225 Door calls in w/4-tone chime to all stations. Chime can be cut out at sub(s). Pick up any station to reply. Press CALL to call other inside stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires to door, non-polarized. 6 wires in loop, between rooms. IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma) Chime Tone Intercom DOOR ROOM 3 IE-2A2DU 2 Door station Master station Sub station Lineup EL-12S AC-10S Electric door strike m P.98 IE-JA Access control keypad, surface mount m P.95 Door station m P.74 IER-2 AC-10F Call extension m P.98 IE-2AD(U) IE-2A2DU IF-DA Master station, 2 door releases Door station m P.74 Power supply Access control keypad, flush mount m P.95 IEH-1CD Master station Sub master station IEH-1C2D 2 door release 12~24V DC power supply 12~16V AC transformer Features Wiring l 3-station chime tone intercom l 2 door stations w/door release l All call type room calling l Chime tone cutout at sub station l Door selective monitoring at master station l AC or DC power source 360m / 1.0mma IE-JA 190m / 1.0mma IE-2A2DU 2 M2 IEH-1C2D M2 EL-12S #1 IE-2A2DU EL-12S #2 H D1 E1 D2 E2 T R C E T R C E T R C E L L L L L L BL BL + – BL 1 E IF-DA BL : Blue(2) IEH-1C2D ( 1) All call type voice calling between rooms (*1) Available in IE-2A2DU or IE-2AD(U) w/RY-3DL Specifications (IE-2A2DU) Power source Unit dimensions Power supply IE-JA 115 IE-2A2DU, IE-2AD(U) Communication 83.5 10 210 83.5 83.5 210 116 IEH-1CD 130 IF-DA 98 H : AC transformer 83.5 28 100 68 100 61 Door release Wiring Wiring distance AUDIO ENTRY SECURITY IE-JA IER-2 2 2 1 2 IER-2 8 IF-DA 1 2 Communication network IEH-1C2D IEH-1C2D 8 12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V AC, 550mA (for both IE & EL-12S). PS-1225 Door calls in w/4- or 2-tone chime to all stations, 45 sec. Chime can be cut out at sub. Pick up any station handset to reply. Press CALL to call other stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized. 6 wires in loop, rooms. IE-2A2DU to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma) 72 Chime Tone Intercom DOOR ROOM 6 IE-8MD 2 Door station Master station Lineup Sub station EL-12S AC-10S RY-AC/A Access control keypad, flush mount m P.95 Electric door strike m P.98 IE-JA Door station m P.71 Access control keypad, surface mount m P.95 AC-10F External signaling relay m P.98 IF-DA IE-8MD Door station m P.71 6-call master IE-8HD 6-call sub master Power supply PS-1225 m P.99 PS-1820 m P.99 Features Wiring l Expandable to 6-station system l Selective or All Call between inside stations l Door select and monitor button (on IE-8MD only) l AC or DC power source l Selective door release control l Chime tone cutout on inside stations, selectable 360m / 1.0mma IF-DA M IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD 2 IE-8HD IE-8MD 4 4 4 M 1 2 IE-8HD 2 1 2 3 EL-12S IE-JA EL-12S 4 IE-8HD 5 IE-8HD 6 IE-8HD H T D1 E1 D2 E2 EL EL SL SL 1 2 3 4 + – 2 1 2 3 4 station # setting 2 4 5 6 3 1 2 3 4 4 1 2 3 4 5 1 2 3 4 6 1 2 3 4 3 4 5 6 4 5 6 4 5 6 4 5 6 4 5 6 H : AC transformer T : PS-1225 U : PS-1820 or AC transformer Internal communication by Selective Call or All Call. Chime tone can be muted at each station selectively. Unit dimensions IF-DA 130 Power source 83.5 210 98 Specifications (IE-8MD) Power supply IE-8MD IE-8HD 83.5 AUDIO ENTRY SECURITY M M 4 1 1 Communication 28 IE-JA 110 83.5 115 116 73 4 IE-JA 2 Communication network IF-DA 190m / 1.0mma 10 79 Door release Wiring Wiring distance 12~16V AC, 900mA 12~18V DC, 500mA Intercom only; 12V or 18V DC power supply. AC transformer 12V AC, 10VA or 16V AC, 14VA w/no load voltage 20V or less. Intercom + EL-12S; 12V AC, 10VA only Door calls in w/4- or 2-tone chime and LED, 45 sec. Pick up any handset to reply. Press 1 ~ 6 to call other station with pretone and voice or All Call. Single channel, common talk system. Contact rating: 24V AC/DC, 350mA 2 parallel wires, to door. 4 wires in loop, between rooms. IE-8MD to door 150m(0.65mma) 360m(1.0mma) Rooms 75m(0.65mma) 190m(1.0mma) Audio Door Stations IE/IF Series Unit dimensions IF-DA 98 160 83.5 AX-DM 130 28 43 IE-JA Audio door station Mullion type 116 10 120 83.5 AX-DM IE-SS/A 115 IF-DA Door station 22.5 120 84 Surface mount station 50 Flush mount station Specifications Wiring Wiring distance 2 parallel wires to master, non-polarized 150m(0.65mma) 230m(0.8mma) 360m(1.0mma) Features IE-JA Door station IE‑SS/A Audio door station l Weather resistant audio door stations l Hands-free communication l Call button rings chime or tone at inside station Some applications l At multiple doors w/TB-AD10 Used for IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24) TC-M w/TB-AD1 TC-M w/TB-AD10 AX AUDIO ENTRY SECURITY 74 External Signaling Relays External Signaling Relays 105 RY-ES 41 71 RY‑ES External Signaling Relay Specification Power Source RY‑ES: 12~24V DC, 12~16V AC – supplied by Master Station Contact Rating RY‑ES: 125V AC, 1.0A 30V DC, 1.0A Features (RY‑ES) • • AUDIO ENTRY SECURITY 75  llows an external device to be triggered A when the intercom is called External device will be activated when the door station calls in Used with: RY‑ES – AX Series, DB Series, JF Series, JK Series, JO Series, JP Series, or KB Series INTERCOM SYSTEM Intercom systems for a variety of facilities where effective communication is needed. Lineup JP-4MED Open Voice Intercom Open Voice Intercom LEM system LEF system Handset Intercom Handset Intercom Hands-free Intercom DB-1MD Master / Sub Intercom TC-M P91l P85 Security Window Intercom Handset Intercom YAZ-90-3W AT-406 P85 P81l P79 l P77 IMU-100 TD-H/B P86 INTERCOM SYSTEM 7-inch Touchscreen Color Video Intercom P8 7l P8 9l Market-Com MC-60/4A P94 76 7-inch Touchscreen Color Video Intercom DOOR Features ROOM 8 JP-4MED 4 • • • • • 7-inch touchscreen for operation Hands-free or handset audio communication Zoom/wide and pan & tilt video monitoring function Video image adjusting function Record visitor images both automatically & manually Door station Master station 2 2 Cat5e 2 2 2 JP-DV Wide and Zoom & PanTilt Vandal resistant video door station, surface mount 2 2 2 3 connectors 2 2 PT JP-4MED PS24 Hands-free color video intercom master station RY-3DL Multiple door release adaptor or GT-D JPEC Audio door station JP-DA JP-DVF* Wide and Zoom & PanTilt video door station, surface mount Wide and Zoom & PanTilt Vandal resistant video door station, flush mount Handsfree module for JP-4MED & JP-4HD JP-DVF-L Wide and Zoom & PanTilt Vandal resistant video door station, flush mount (Guidance-enabled type) INTERCOM SYSTEM JPTLIIP Power supply PS-2420  P.100 IP Interface for JP System (compatible with iOS and Android) * Marine grade option available Features Wiring Internal communication Refer to P.5 for details Select a single master station to call. JP-4HD JP-4HD Door station 1 M(OUT) M (IN) M(OUT) A1 A2 1A1 1A2 M(OUT) M (IN) ~ Individual call Simultaneously make an announcement to all master stations. JP-4MED ~ All call JP-DV A1 A2 4A1 4A2 *Same as door station 1. (Up to 7 sub master stations.) 4-pin option connector 12-pin option connector EL-12S S S 1 E IER-2 L1 L1 EL-12S L2 L2 PT Audio monitoring of other master stations Communication network All stations can be set to audibly monitor other master stations. JP-DV (Master station) JP-4MED PS24 (Sub master station) JP-4HD No.3 No.4 ~ Monitoring No.7 No.8 M The design and specifications are subject to change without notice for improvement. 77 • 3 wiring methods selectable (Station-to-station, Homerun, or combined wiring) • 2 internal calls selectable (All call or Individual call) • Audio monitoring of other master stations • Option: 3 sensors connectable to the master station Commercial Residential Retail Shops Factories Schools Sub master station JP-4HD JP-4HD Cat5e Cat5e JP-4HD Cat5e JP-4HD Cat5e PS24 JP-4HD Cat5e Hands-free color video intercom sub master station JP-4HD Boxed sets JP-4HD Cat5e JPS-4AED: JP-4MED, JP-DA, PS-2420 JPS-4AEDV: JP-4MED, JP-DV, PS-2420 JPS-4AEDF: JP-4MED, JP-DVF, PS-2420 Lineup Access Control m P.95 Jx-DVF-AC AC-10S JPW-BA Long distance adaptor m P.6 Jx-DVF-AC + JP-DVF JP-DV GT-D 28.5 IER-2 100 132 135 RY-3DL 45 140 98 33 AC-10F 83.5 98 27 74 JP-8Z 45 117 Electric door strike m P.98 RY-3DL Multiple door release adaptor m P.6 88 29 123 Video monitor Pixels Video output Night viewing 61 Wiring distance (m P.5) 24V DC PS-2420 Max. 340mA(JP-4MED). Max. 200mA (JP-4HD) Chime. Image & audio, approx. 45 or 90 sec. Automatic(Hands-free): approx. 1 min. To activate, touch TALK button. Handset: approx. 3 min. To activate, lift handset. 7-inch color LCD screen 1,150,000 pixels NTSC/PAL, 1Vp-p/75d Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: CAT5e Door to Master: 100m (1.0mma) Master to farthest sub: 300m(CAT5e) 309 5.6 5 45 Power source Power supply Consumption Calling Communication Door release Option output Wiring 42 109 125 295 98 25 5.6 209 173 30.5 55 AC-10S 8 JP-DVF 130 97 120 48 68.5 145 129 JP-DA 255 JP-DVF-L EL-12S Specifications (JP-4MED,JP-4HD) JP-4MED, JP-4HD 144 Distribution adaptor JP-DV + AC-10S Unit dimensions Jx-DVF-AC JP-8Z INTERCOM SYSTEM Access control keypad, surface mount PS24 150 30 45 Also refer to P. 3-6 for details. 78 Open Voice Intercom DOOR ROOM 1 LEM-1DL 1 Door station Master station Lineup AC-10S Access control keypad, surface mount m P.95 LE-DA LE-D Sub station m P.84 Sub station m P.84 LEM-1DL Master station AC-10F Access control keypad, flush mount m P.95 EL-12S Electric door strike m P.98 LE-DL Power supply PS-1225 Sub station m P.84 m P.99 Features Wiring INTERCOM SYSTEM l Single door open voice access control system l Adjustable tarnsmit (front) and tone volumes l AC/DC power supply (1) 300m / 0.8mma LE-D LEM-1DL 2 Communication network 2 M LE-D 1 E – LEM-1DL 1 E EL-12S 12V AC, 125mA ( M (2) EL EL + – ) LE-D H LEM-1DL 2 M Unit dimensions LE-D 1 E – LEM-1DL 2 1 E EL-12S EL EL 120 83.5 180 PWR 29 88 143 LE-DA 53.5 Specifications (LEM-1DL) LE-DL 83.5 175 83.5 115 10 120 Power supply Communication 25.5 Wiring Wiring distance 79 H/T (1) Using EL-12S door release (2) Using door release of other manufacture rated : 30V AC/DC, 1A max. Do not remove shorting link on LE-D. PWR : Power source Power source 116 + – 12~16V AC, 4VA 12~24V DC, 200mA (24V) AC transformer, PS-1225 When called by tone, press TALK to reply. Press door release button to release door, and press OFF for standby. 2 wires, non-polarized (+2 for EL-12S) LEM-1DL to door 200m(0.65mma) 300m(0.8mma) Open Voice Intercom MASTER SUB 3 LEM 1 Master station Door station Room sub station LE-D Sub station m P.84 LEM-1 1-call master LE-A Sub station m P.84 LEM-3 3-call master LE-DA Sub station m P.84 Power supply 6VDC2500/1 m P.99 LE-AN Privacy sub m P.84 Features Wiring 300m / 0.8mma LEM-1 LEM-1 INTERCOM SYSTEM l Open voice communication l Push-to-talk at master, hands free at remote l LE sub stations: either door station or room sub station l Voice volume control LE-A 2 Communication network LEM-1 LEM-1 1 E LE-A 1 E – + – LEM-3 LEM-3 300m / 0.8mma LE-D 300m / 0.8mma LEM-3 2 LE-A LEM-3 LE-D W LE-A 2x2 LE-AN 2 LE-AN 1 1 E – LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from sub E Unit dimensions 2 1 E – 3 LEM-3 + – W 1 E – ★ Do not remove shorting link on subs. 180 160 LEM-1, LE-A, LE-AN Specifications (LEM) 131 51 143 LE-D 115 83.5 29 116 Power source Power supply Communication 83.5 LE-DA 120 88 53.5 10 Output Wiring Wiring distance 6V DC 6VDC2500/1 Sub calls in w/tone and LED, 20 sec. Depress selector button and press or release TALK button. Sub called by tone or voice. Reply hands-free. 350mW output, adjustable 2 parallel wires per sub, non-polarized LEM to sub 200m(0.65mma) 300m(0.8mma) 80 Open Voice Intercom STATION 11 LEF Master station Master station LEF-3 3-call master LEF-5 LEF-10 LEF-5W LEF-10W 5-call master LEF-3L 3-call master w/ door release button 5-call master w/terminal box LEF-10S 10-call master 10-call master (all call) 10-call master w/terminal box Power supply PS-1225 m P.99 Features INTERCOM SYSTEM l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA) Wiring Door answering w/selective door release 300m / 0.8mma LE-D #2 LEF-5 E LE-D M M LEF-5 EL-12S EL-12S Selective call between inside stations. Answering & releasing door from any inside station Cabling Models LEF-3 LEF-5 LEF-10 LEF-10S Capacity 4 stations 6 stations 11 stations 11 stations Cable 9 wires 11 wires (+5: K1~K5*) 17 wires (+10: K1~K10*) 20 wires (+10: K1~K10*) l K1 ~K10: Control terminals for video, door release. l LEF-3 does not have L terminal. l Door & inside sub stations can ring 2 or 3 LEF masters. l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs) 81 3 1 C 3 4 5 1 2 C 4 5 1 2 3 – E R Y + – E R Y + – L L Q Q L K4 K5 K4 K5 K4 K5 YL LEF-5 LEF-5 13 E R Y + – E – LEF-5 13 C 2 3 4 5 1 1 LEF-5 4 RY-PA's Communication network LE-D LE-D #1 3 BK H C : PS-1225 H : AC transformer Terminal 4 : for LE-D #1, Terminal 5 for LE-D #2. YL : Yellow(2) BK : Black(2). T Door station Room sub station Lineup All call, music & chime EL-12S Electric door strike m P.98 BG-10C LE-D Sub station m P.84 Sub station m P.84 Door release relay m P.98 LEW-5 LEF-5 terminal box All call, chime & music adaptor m P.84 LE-A RY-PA LEW-10 LEF-10 terminal box LEW-10S LEF-10S terminal box LE-DA AC-10S Sub station m P.84 Access control keypad, surface mount m P.95 LE-AN Privacy sub m P.84 Unit dimensions BG-10C LE-D 18 3 LEF-10S LEF-10S LEF-10S LEF-10S 22 22 22 131 143 53.5 1 E E – – EL-12S H YL BK C 2 3 4 5 6 7 8 9 10 1 E R Y + – L 1 C 3 4 5 6 7 8 9 10 2 E R Y + – L 1 2 C 4 5 6 7 8 9 10 3 E R Y + – L 1 2 3 C 5 6 7 8 9 10 4 E R Y + – L Q Q K9 K10 K9 K10 K9 K10 K9 K10 P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 + – T 3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to wire multiple subs (2 common + 1 per sub). l LE-D call-in chimes on LEF stations. l Only LEF-10S station can transmit all call. l Match door release control terminals (Kn) with door selector #10 with K10, #9 with K9. ★ Remove a shorting link on LE subs. T : PS-1225 H : AC transformer Q : RY-PA 165 1 2 3 4 5 6 7 8 DB DA 11 E R Y + – M EL-12S 51 55 190 BG-10C M 1 LE-A, AN 206 3 180 LE-D LEF-5, 10, 10S 250 77 INTERCOM SYSTEM LEF-3 Intermixed configuration 160 Wiring AC-10F Access control keypad, flush mount m P.95 Specifications (LEF) Power source Power supply Communication Door release Selector switch Wiring Wiring distance 12V DC, 300mA per LEF station. PS-1225 Sub calls in w/(chime) tone & LED, 20 sec. Depress the LED lit selector button. Use TALK/LISTEN switch. Master calls in w/tone or voice (no LED lit). Reply hands-free. To call, depress a selector, and call by voice or tone. Contact: 30V DC, 0.1A (resistance load). Contact: 12V DC, 30mA. 5 wires common + no .LEF (& subs) (all-master system) 2 wires per sub (single-master system). * E to - link remains attached. LE subs: 3 wires with the link removed (when intermixed) Farthest LEF’s 200m(0.65mma) 300m(0.8mma) Specifications (BG-10C) Power source All call transmit All call receive Chime tone transmit Controls Wiring Wiring distance 12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma). 82 Open Voice Intercom DOOR ROOM 8 LEF-C 3 Door station Master station Sub station LE-D Sub station m P.84 LEF-1C LEF-3C All call sub master 3-call master LEF-5C LEF-10C 5-call master 10-call master Power supply PS-1225 m P.99 Features INTERCOM SYSTEM l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA) Wiring LEF-10C✕7 (20) 1 LEF-10C LEF-10C LEF-10C E – LEF-10C DA EL-12S Intermixed configuration Internal communication by Selective call. Sub calls in with tone & LED 20 sec. 9 10 11 E R Y + – P1 P2 P3 + – Power source Power supply Communication 15.5 15 20 83 200 15.5 40 20 208 200 208 238 Output 153 1 C 2 3 4 5 6 7 8 9 10 1 E R Y + – L P1 P2 P3 1 C 2 3 4 5 6 7 8 9 10 2 E R Y + – L P1 P2 P3 1 2 3 C 4 5 6 7 8 9 10 3 E R Y + – L 1 2 3 4 C 5 6 7 8 9 10 4 E R Y + – L 1 2 3 4 C 5 6 7 8 9 10 5 E R Y + – L 1 2 3 4 5 6 C 7 8 9 10 6 E R Y + – L 1 2 3 4 5 6 C 7 8 9 10 7 E R Y + – L P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 P1 P2 P3 153 Door release 15.5 15 20 1 1 E E 1 E – – – T DCIN LEF-1C LEF-5C LEF-10C 19 16 16 16 H : AC transformer Specifications (LEF-C) Unit dimensions LEF-3C 17 T : PS-1225 Q : RY-PA relay BK : Black(2) YL : Yellow(2) LEF-10C LEF-10C – BK YL Q H LEF-10C 1 2 3 4 5 6 7 LE-D Communication network LE-D 17 3 BG10C Selector switch Wiring Wiring distance 12V DC, 300mA per station. PS-1225 Sub/door calls in w/tone & LED, 20 sec. Depress the LED lit selector button. Depress TALK/LISTEN switch. The LED stays lit while in use. Single talk channel w/OCCUPIED lit. 800mW at 20d (receive). 500mW at 20d (transmit). Contact: 110V AC, 1A. 24V DC, 1A. (on RY-PA output). Contact: 12V DC, 1A. (K terminals) 5 or 6 common + no. all stations Farthest LEF-C’s 200m(0.65mma) 300m(0.8mma) LE Sub stations & Accessories Weather-resistant sub Unit dimensions Sub station LE-DA 88 Sub station 29 116 83.5 175 115 120 LE-D LE-DL 83.5 LE-DA 83.5 LE-D 10 25.5 120 LE-DL Sub station LE-DA; 2-gang mounting Room sub Unit dimensions 160 LE-A, AN 131 LE-A Sub station 51 LE-AN Privacy sub All call sub master 84 LE-SS/A LE‑SS/A Audio Door Station 153 120 LEF-1C Specifications (BG-10C) Unit dimensions Power source 165 BG-10C 250 BG-10C All call, chime & music adaptor 15 All call sub master 50 All call/music/chime adaptor 15.5 20 84 Audio Door Station 120 LE‑SS‑1G LEF-1C 50 208 70 Unit dimensions INTERCOM SYSTEM 114 LE-SS-1G 77 All call transmit All call receive Chime tone transmit Controls Wiring Wiring distance 12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma). 84 Hands-free Intercom MASTER SUB 4 DB-1MD 1 Features • • • • Total hands-free communication, auto-voice actuation Press-to-talk operation available Up to 5 stations All call for internal communication Unit dimensions Wiring 100m / 1.0mma DB-1MD/1SD DB-1MD 4 2 4 2 4 4 2 80 DB-1MD Master station Sub master station PT : AC transformer DB-1SD DB-1SD 185 DB-1SD DB-1SD DB-1SD DB-1SD IN B1 B2 B3 B4 OUT B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 IN B1 B2 B3 B4 OUT B1 B2 B3 B4 IN B1 B2 B3 B4 ~ ~ ~ ~ ~ ~ ~ ~ 27 B1 B2 B3 B4 PT PT DB-1SD DB-1SD D E ~ ~ 16VAC1500/5 m P.99 16VAC1500/5 P : Polarized 16VAC1500/5 Specifications (DB-1MD, 1SD) Power source AC transformer Communication 16V AC 16VAC1500/5 Approx. 10 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button twice. Handset Intercom MASTER 3 AT-406 INTERCOM SYSTEM Master station Sub station 16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma) Features SUB 1 Wiring distance • • • • Handset master-sub intercom w/2 additional subs (optional) Battery status LED Batteries or DC power supply Buzzer or bell activation (optional) Boxed set AT-406 Boxed set (white color) AT-406B/A Boxed set (charcoal gray) Power supply AT-306 Master station 6VCD2500/1 or Batteries m P.99 Sub station Communication network AT-206 AT-306 x 3 Wiring Unit dimensions AT-206 AT-306 AT-306 AT-206 210 1 2 Master calls all the subs simultaneously, while the sub rings the master only. 80 2 AT-306 2 83.5 2 AT-306 51 W NP + --- 1 2 NP 1 2 NP 1 2 W : 6VDC2500/1 Specifications (AT-406) Power source Power supply Communication 85 6V DC 6VDC2500/1 or Batteries gAAh (SUM-3) x 4 pcs Press CALL button to ring all subs. Pick up any phone. Sub rings master only. Common talk. Wiring Wiring distance 2 parallel wires. non-polarized 2-station set 700m(0.65mma) 1000m(0.8mma) AT-206 to subs 1~3 400m(0.65mma) 600m(0.8mma) Handset Intercom STATION 90 YAZ-90-3W Phone extension Lineup YAW-RB 1-zone paging adaptor for YAZ-90-3W Power supply PS-2420 YAZ-90-3W Phone master station m P.100 Features Communication network YAZ-90-3W Paging Speaker YAZ-90-3W 2900m / 0.8mma #10 4P YAZ-90-3W #39 #40 3P 4P YAZ-90-3W YAZ-90-3W YAW-RB 1 2 1 2 1 2 1 2 3 4 3 4 3 4 3 4 5 6 + – 5 6 + – 5 6 + – 5 6 + – N N M G A Paging amp. IN White TB P G OUT Paging speaker line shielded Power relay White AC Paging speakers Power supply (for relay) l Remove +,- wires between YAZ stations of different blocks. Within a block locate a power supply in the center of cable run, and make groups of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to each group's initial YAZ station. N : PS-2420 YAZ-90-3W YAZ-90-3W Specifications (YAZ-90-3W) Power source Power supply Communication Station to station communication in any pair Unit dimensions Line loop resistance Wiring Total wiring distance YAW-RB YAZ-90-3W Wiring INTERCOM SYSTEM l Microprocessor built-in intercom expandable to max. 90 stations on 4-pair cable l Up to 2.9km wiring distance l Zone paging l Communication functions: Camp-on busy, secretary transfer, call transfer l Line-off trouble on one channnel does not affect the other channels 24V DC, 150mA max. 20mA standby. PS-2420 per 30-station block. Dial 2-digit station # to ring other station with tone or voice pressing PAGE. Privacy communication on each channel (max. 3). Must not exceed 200d for farthest stations. 20d for power line. 4-twisted pairs (shielded) in loop. Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma) 158 83.5 230 Specifications (YAW-RB) 152 94 84 Power source Consumption Paging impedance/level 59 Music impedance/level Line resistance Amp. power ctrl. contact YAW-RB: 24V DC, 150mA (paging).40mA (standby). YAW-RB = 5 YAZ’s, powered by YAZ network. Input: 600d/78mV(RMS), 1KHz. Output: 600d/300mV(RMS), 1KHz. Input: 20Kd/300mV(RMS), 1KHz. Output: 600d/150mV(RMS), 1KHz. 20d loop for power supply line. 200d loop for intercom line. YAW-RB: 240V AC 10A. 24V DC, 10A. 86 Handset Intercom STATION 25 TD-H/B Door station Sub station Master station TD-1H/B TD-3H/B IF-DA Door station m P.74 DE-UR Door station adaptor Power supply PS-1225 m P.99 1-call sub TD-6H/B 3-call master 6-call master Wiring Features INTERCOM SYSTEM l All-master selective ring system l Single-master configuration or intermix w/TD-1H/B l Multi-conductor cable in loop l Multi-talk channels l Door station(s), audio or PanTilt video (max. 2) l Zone paging, with or without talkback l Music source connection. Page pretone cuts out music. (2) Door station communication 230m / 0.8mma 1000m / 0.8mma IF-DA DE-UR 1 1 2 1 2 1 2 C 2 TD-6H/B #1 10 #2 C 2 3 4 5 6 1 C 3 4 5 6 1 2 C 4 5 6 1 2 3 C 5 6 1 2 3 4 5 6 1 2 3 4 C #4 10 #5 10 Communication network TD-12H/B TD-12H/B TD-12H/B Paging Speaker TD-12H/B TD-12H/B TD-12H/B IF-DA All-master configuration. Station selector & CALL to ring any other station. Wiring (1) All-master configuration TD-12H/B TD-12H/B #1 #2 16 1 2 C D D D D D D D + – + – + – + – + – + – + – A B T 1000m / 0.8mma #3 16 #11 #12 16 16 15m / 0.8mma #13 16 (3) Single-master configuration TD-3H/B C 2 3 4 5 6 7 8 9 10 11 12 1 D + – 87 #3 10 1 C 3 4 5 6 7 8 9 10 11 12 2 D + – 1 2 C 4 5 6 7 8 9 10 11 12 3 D + – T 1 2 3 4 5 6 7 8 9 10 C 12 11 D + – 1 2 3 4 5 6 7 8 9 10 11 C 12 D + – 1 2 3 4 5 6 7 8 9 10 11 12 C D + – l Install main cable of max. condctors allowed for each TD-H/B station model. C Terminal D : Door station TD-1H/B 6 C 1 2 3 TD-1H/B 5 1 C TD-1H/B 4 1 C 1 C D T + – + – + – + – Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power supply. Lineup PD-1 Zone page adaptor For desk-top or surface wall mounting, provide TDW-n/A terminal box w/1.5m cord. PD-2 Zone page/talkback adaptor TDW-1/A TD-1H/B terminal box TDW-3/A TD-3H/B terminal box TDW-6/A TD-6H/B terminal box TDW-12/A TD-12H/B TD-24H/B 12-call master TD-12H/B terminal box Power supply PS-1225 TD-24H/B terminal box m P.99 TDW-24/A 24-call master Wiring External signaling relay m P.98 Specifications (TD-H/B) PD-1 (1) TD-12H/B 3 (1) T Wiring A G M No. C DC12V + --- + --- TD-H/B + --- Wiring distance T (PD-1,PD-2) (5) Paging with talkback w/PD-2 (single zone) (2) PD-2 TD-12H/B Power source Output Paging & music tone controls Amp. input Music input Tuner output Tape output Talkback gain Environmental noise Paging (1) 3 T (1) S S V V A G M (2) No. C DC12V + --- + --- + --- TD-H/B T (1) Paging Speakers (2) Talkback speakers T : PS-1225 Wiring Unit dimensions 210 210 73 83.5 91 100 AUX or PHONO 100K-500Kd, 0.12~0.5V 17Kd, 0.3V, 1KHz. for full output Audio output: Range 100mV~1.2V, 10Kd or less Low level output: Range 100mV~1.2V, 600d 40dB, 1KHz. at max. volume Less than 80dB (phon) Select an assigned selector # and page w/PAGE button depressed. Release to receive reply 3 wires to TD-H/B via power supply PD-1 PD-2 TD-24H/B 83.5 PD-1: 12V DC, 300mA. PD-2: 12V DC, 48mA (talkback). 5Kd . Max. 1.5V Treble 12dB at 10KHz. Bass 12dB at 100Hz. 138 TD-1H/B ~ TD-12H/B 12V DC, 70mA per station. PS-1225 Depress a station selector 1~12 and CALL (or CALL A) to ring station 1~12 (or A1 ~ A12). Lift handset to reply. Door calls in w/standard or faster(B) intermittent tone, 2-1/2 sec. Pick up and depress the selector assigned. 2 or 3 + no. TD-H/B in loop. TD-1H/B: 4 wires. TD-3H/B: 7 wires. TD-6H/B: 10 wires. TD-12H/B: 16 wires. TD-24H/B: 28 wires. TD-H/B stations 650m(0.65mma) 1000m(0.8mma) DE-UR to door 150m(0.65mma) 230m(0.8mma) INTERCOM SYSTEM Power source Power supply Communication (4) Straight paging w/PD-1 (single-zone) 100 RY-AC/A 51.5 83 88 Security Window Intercom SERVICE SIDE 1 PUBLIC SIDE 1 IMU-100 Service Side IMU-100 Main kit IMU-100  IME-100 Operation unit IME-100 Gooseneck microphone Main unit Power supply PS-2420 m P.100 Features INTERCOM SYSTEM l First in industry! Using an acoustic tube with noise cancelling microphone l Voice-actuated hands-free communication l Flexible gooseneck type microphone l Optional Mono type headset (a3.5 plug) l Detection sensor switches automatically to communication mode l Separate speaker system using an optional microphone l Paging feature for announcements l Thin shape of the acoustic tube does not obstruct the field of vision l Holes in the barrier glass are not necessary to install Communication network Acoustic tube system 3 Paging speaker ISE-100 2 Barrier glass IAI-100 + IAX-100 1 IMU-100 + IME-100 Service Side 1 2 3 Public Side Voice-actuated hands-free communication Automatically switch to communication mode Paging Separate speaker system 3 2 External speaker Paging speaker ISE-100 + Barrier glass IME-150 3 IMU-100 + IME-100 Service Side 89 Public Side Lineup Public Side Acoustic tube system Separate speaker system IAI-100 Acoustic interface kit ISE-100 Sensor External Speaker (locally available) IAI-100  IAX-100 Driver unit + Paging speaker (locally available) IAX-100 Acoustic tube Acoustic I/O tube IME-150 Optional microphone Unit dimensions Wiring Supplied cable IMU-100 + IME-100 Cord (3.5m) IME-150 160 27 ISE-100 Paging speaker 130 40 210 49 Cord (3.5m) Shielded cable 2 370 2 Shielded cable External speaker + 24 388 2 2 2 206 Mic. Acoustic I/O tube Operation unit 45 Speaker Main unit Separate speaker system IME-100 63 420 14.5 510 2 34 INTERCOM SYSTEM 20m / (1.2mma) 3800 40 IAX-100 24 N 1000 W1 E – + ST-BY SW – SW + PG OUT C H DC24V + – WHITE(C) BLACK(H) 150 72 3500 68 Shielded(E) WHITE(-) RED(+) Shielded WHITE RED Connection cord (approx. 3.5m) Shielded WHITE RED Connection cord (approx. 3.5m) W3 Specifications (IMU-100) Power source Power supply Consumption Operating temperature Communication Headset N External speaker Paging speaker N : PS-2420 36 30 C H 105 W2 115 Connector Driver unit 84 23 ISE-100 3500 60 Separate speaker system 13 IME-150 Supplied cable (approx. 2m) 27 24V DC PS-2420 120 mA (standby) 780 mA (maximum) 0kC to 40kC Voice-actuated communication Transmit output: 3 W 4 d, Receive output: 1.5 W 16 d a3.5 plug, Impedance: 32 d, Rated input: 40 mW or more, Maximum input: 100 mW or more Impedance: 4 to 8 d, Rated input: 3 W or more Maximum input: 6 W or more Impedance: 4 to 8 d, Rated input: 3 W or more Maximum input: 6 W or more 90 Master / Sub Intercom MASTER SUB 100 TC-M 2 Master station TC-20M 20-call master TC-10M 10-call master TC-20M + TC-40G 60-call Features INTERCOM SYSTEM l Expandable internal telephone intercom l One or dual master configuration l Tone & LED call-in, staying on until answered l Additional buzzer at TB-SE (w/relay) l TRANSFER button on TC-M for communication between two TB-SE subs Wiring TC-10M TC-20M Communication network TC-20G TC-40G TB-SE TC-20M The TC-40GS is equipped with socket to connect the second add-on selector TC-20G or TC-40G. Specifications (TC-M) TB-SE Power source *TB-SE Consumption Power supply Communication TC-20M *TB-SE : Sub station for two-master call. Wiring Wiring distance Unit dimensions TB-SE 480 405 330 255 210 230 210 83.5 115 80 555 630 91 TC-40GS 72 18V DC, 350mA. 15~16V AC, 50/60Hz, 750mA. 6W. 3W standby. PS-1820 AC transformer. Pick up TB-SE handset. Rings TC-M, w/tremolo & LED, staying. At TC-M, pick up and press a lit selector to reply. 2 parallel wires per TB-SE, non-polarized. TC-M’s 200m(0.65mma) 480m(1.0mma) TC-M~TB-SE 400m(0.65mma) 900m(1.0mma) Add-on selector Lineup Sub station IER-2 Call extension m P.98 TC-20G 20-call add-on selector TB-SE Sub station TC-40G Power supply PS-1820 40-call add-on selector TC-40GS m P.99 W/add’l 20-/40-call expansion Wiring 2 Wiring 1 480m / 1.0mma TC-M 2 2 2 TB-SE 2 2 2 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 3 4 5 6 7 8 9 2 10 TB-AD1 E E 3 TB-SE 2 E E E E E E E E E E M C E E M C 1 2 E 9.TB-SE 1 E E E S IER-2 E E + - 12V T S R S 2 IF-DA E E TB-SE TC-M U U E 900m / 1.0mma 1 2 3 4 5 6 7 8 1 TB-SE 2 1 2 1 2 1 2 1 2 1 2 1 2 2 1 2 1 2 2 19 20 + – T R N + – T R TB-AD1 5 (x3) TB-AD1 TB-AD1 2 2 2 2 TC-20M 10 + 12V T S R 5 2 2 9 TC-20M TB-AD1 2 2 INTERCOM SYSTEM 900m / 1.0mma TB-SE IF-DA IF-DA IF-DA TB-AD1 1 E IER-2 l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s. l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system). 92 Master / Sub Intercom DOOR ROOM 1 TC-M & TB-AD10 10 Door station Master station Door adaptor Lineup IER-2 Call extension m P.98 TB-AD1 IF-DA 1-call door adaptor Door station m P.74 TC-10M 10-call master TB-AD10 10-call door adaptor Power supply PS-1820 EL-12S Electric door strike m P.98 m P.99 Features Wiring INTERCOM SYSTEM l Single or multiple audio door communication, expandable l Optional selective door release control IF-DA TB-AD10 2 (x10) Communication network 2 NP 11 EL-12S PT IF-DA TC-M+TB-AD10 1. 1 2 D1 1 2 D2 1 2 D3 1 2 D4 1 2 D10 2. 10. EL-12S ( 10) M Pre-tone sounding or mute selectable at TB-AD10. Unit dimensions TB-AD1 TB-AD10 E E E E D1 D2 D3 D4 10 10 D10 DE D10 DE 12V 12V T R T R TB-AD10 2 L2 L2 L3 L3 L10 L10 EL-12S TC-20M + TC-20G TB-AD10 1 97 T TC-20M TB-AD1 L1 L1 L4 L4 U 230 140 83.5 150 Wiring 2 D1 D2 D3 D4 PRE-TONE ON OFF TB-AD10 3 42 IF-DA 1 2 3 4 E IF-DA 74 1 2 3 4 2 IF-DA 10 5 2 2 IF-DA 10 IF-DA 10 Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after. 1 2 1 2 N + – T R 2 U : PS-1820 Specifications (TB-AD10) U TB-AD1 5 (x3) TB-AD1 TB-AD1 2 19 20 + – T R 2 Wiring TC-20M IF-DA 93 IF-DA Power source Door capacity Communication IF-DA Wiring distance TB-AD10: 12V DC, supplied by TC-M. 10(TB-AD10). 1(TB-AD1). Door calls in w/tremolo & LED 40 sec. Pick up and depress LED lit selector. Pretone sounds at door, or silenced. 2 parallel wires to door, non-polarized. 4 common + no. doors, TC-M to adaptor. TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma) TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma) Market-Com STATION 60 MC-60/4A Market-com station Market-com adaptor Lineup Paging speaker w/built-in transformer (locally available) MC-A/A Zone page adaptor Power supply PS-2420 MC-60/4A Market-Com station m P.100 Features Wiring S MC-60/4A 10 3 #1 2 1 1 7 7 7 7 7 7 7 7 2 3 MC-60/4A 10 7 7 7 7 7 7 7 7 #2 MC Communication network #3 #4 MC-A/A A G M (1) MC-60/4A MC-60/4A (2) Ch.1 Ch.4 (1) Paging (2) Select a channel 1~4 paged, and communicate. Unit dimensions MC-60/4A #1- 10 3 2 1 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1/+ 2 3 4 5/– 6 7 N MC-A/A 1 2 3 10 -#2 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 2 3 4 5 6 7 INTERCOM SYSTEM l Max. 60-station paging & communication system l Selective 4 talk channels with in-use LED’s l Conference call among 3 stations l Music cutout during paging l Reinforced modular coil cord #3~#6 143 83.5 234 Station blocks #1~6 of max. ten MC-60/4A’s N : PS-2420 91 90 Specifications (MC-60/4A) 51.5 94 Specifications (MC-A/A) Power source Amp. input Music soursce output 24V DC, PS-2420 AUX 10Kd, 0.3V~0.5V Range 100mV~1.2V, 10Kd or less Power source Power supply Communication Talk channel Wiring Cable specified Wiring distance 24V DC, 70mA max. (in page). PS-2420 at MC-A/A. Pick up and depress channel selector 1~4 and page w/PAGE button. Called party picks up and presses lit LED channel button. 4 and a separate paging channel. 7 wires in loop, non-twisted. Line capacitance less than 25pF/30cm. MC-A/A to MC-60/4A(*) 500m(0.65mma) 750m(0.8mma) Total wiring distance 1500m(0.65mma, 0.8mma) (*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of different blocks. 94 Accessories Access control Surface mount AC-10S Vandal resistant access control keypad, surface mount Features l Two types of keypads are available. AC-10S: Surface mount type AC-10F: Flush mount type l AC-10S matches JK-DV, JO-DV and JP-DV, color video door stations. l Vandal resistant panel, zinc die cast, and tamper proof screws are included. l Two independent relay outputs (N/O or N/C) are available. When same access code is programmed for both #1 and #2, two relays activate simultaneously. l Programmable up to 100 access codes* 4, 5, or 6 digits in length. * #1: up to 60, #2: up to 40 l Keypad lockout: After too many incorrect access codes are attempted. l Anti-tailgate: As soon as the door is closed after access is granted on #1, the door is locked even before programmed output time. Prevent sneak in. l One push door release with external timer connection: While the external timer is on operation, access code is not required. Press “0” key only. Programmable #1 and/or #2. l External output for alarming: When “Lockout” or “Forced entry” occurs, external output is available at #2. l Two LED indicators show the status of the access control system. l Illuminated keypad is easy to read. l Audible key press Features l Activate door release (relay) By keypad By request to exit/entry button Enter ID #1 1 4 7 A 2 5 8 0 #1 #1 3 6 9 B 1 4 7 A #2 Green #2 2 5 8 0 3 6 9 B #2 #1 #2 Beep JK-DV, AC-10S m P.10 Press button Orange l Keypad lockout Bleep Flush mount The keypad is locked out after too many incorrect access codes are attempted. 1 4 7 A 2 5 8 0 3 6 9 B Programmable l Incorrect access code: 10-99 times l Lockout time: 10-99 seconds Blink keypad 4 times Blink LED (orange) programmed period Sound buzzer approx. 3 seconds l Anti-tailgate Door sense switch ACCESSORIES Enter ID for #1 Lock 1 2 3 4 5 6 7 8 9 A 0 B AC-10F Vandal resistant access control keypad, flush mount l One push door release with external timer connection During the timer is on operation ON: 9AM-5PM Power source 12-24V DC power supply 12-24V AC transformer ★ 95 Press “O” key 1 4 7 A 2 5 8 0 3 6 9 B The design and specifications are subject to change without notice for improvement. Unlock Door is locked 1 second after door was closed even during relay on-time. Wiring (1) Relay #1 (Normally open) (2) Relay #1 (Normally closed) & Relay #2 (Normally open) 300m /1.0mmø #1 Electromagnetic door strike 300m / 1.0mmø 2 MH2 2 12V-24V AC/DC V V SW #1 PB1 PB2 C T Common #1 Electric door strike NO1 C1 NC1 M H Request to exit switch #1 NO2 C2 NC2 2 Power source V V SW #1 SW #2 Common Timer PB1 PB2 C T #1 Electromagnetic door strike Nomally closed M NO1 C1 NC1 2 12V-24V AC/DC 300m (18V - 24 AC/DC, 0.65 - 1.0mmø) 12V-24V AC/DC Relay #1 N/O 2 2 door strike 300m (18V - 24 AC/DC, 0.65 - 1.0mmø) Power source AC-10S M MH2 #2 Electric AC-10S #1 Electric door strike 2 Relay #1 N/C C M #2 Electric door strike H NO1 C1 NC1 NO2 C2 NC2 12V-24V AC/DC Request to exit switch #1 Request to exit switch #2 Timer Relay #1 N/C Relay #2 N/O H : AC transformer C : Power supply Unit dimensions Specifications (AC-10S, AC-10F) 25 33 29.5 117 5 45 Access code Number: Up to 100 (#1: 60, #2: 40) Code length: From 4, 5, or 6, (0 ~9, A, B) Two conductors Access control ~ Power source: 100m (12V – less than 18V AC/DC, 0.65 – 1.0 mmø) 300m (18V – 24V AC/DC, 0.65 – 1.0 mmø) Access control ~ Request to exit button 300m (0.65 – 1.0 mmø) Wiring Wiring distance Back Box 173 100 JK-DV + AC-10S 12 – 24V AC or 12 – 24V DC Max. 100mA Output: 2 Contact rating: 24V AC/DC, 3A (resistive load), 1A (inductive load) Dry contact: Normally open or Normally closed Operating time: From 1 second to 99 seconds 100 125 98 132 AC-10F 55 68.5 AC-10S Power source Consumption Relay 45 Environment Weather resistant (IP54 equivalent) 5 85 125 ACCESSORIES 98 33 Desk Stand Features MCW‑S/A Desk Stand for AX‑8M, AX‑8MV, AX‑8MV‑W, DB‑1MD, DB‑1SD, GT‑2C, GT‑2H, GT‑1C, GT‑1A, JF‑2MED, JF‑2HD, JK‑1HD, JK‑1MED, JP‑4MED, JP‑4HD, JO‑1MD, JO‑1FD, KB‑3MRD, or KB‑3HRD • Allows desk mounting of master and / or handset station • Station is propped up for easier viewing • Pre‑drilled mounting holes • Made of ABS plastic • Adjustable to 45° or 60° angles Used with: AX‑8M, AX‑8MV, AX‑8MV‑W, DB‑1MD, DB‑1SD, GT‑2C, GT‑2H, GT‑1C, GT‑1A, JF‑2MED, JF‑2HD, JK‑1HD, JK‑1MED, JO‑1FD, JO‑1MD, JP‑4HD, JP‑4MED, KB‑3MRD, or KB‑3HRD 96 Accessories Angle Boxes SBX‑DV30 KAW‑D 30˚ Angle Box for IX‑BA, IX‑DA, JF‑DA, JK‑DA, JO‑DA, JP‑DA, KB‑DAR, or KB‑DAR‑M 30˚ Angle Box for JK‑DV, JF‑DV, JO-DV, or JP‑DV SBX‑AXDVF Surface Mount Box for JF‑DVF, JK‑DVF, JO‑DVF, or JP‑DVF ACCESSORIES SBX‑ISDVF Surface Mount Box for IS‑DVF, IS‑IPDVF, IS‑SS, IX‑DF, IX-DF-P, IX-DF-PI or IX‑SS SBX‑1G Surface Mount Box for LE‑SS‑1G 97 Surface Mount Box for AX‑DVF SBX‑ISDVFP Surface Mount Box for IS‑DVF‑HID, IS‑DVF‑RP10, IS-IP4DVF, IS‑IPDVF-HID, or IS‑IPDVF‑RP10 SBX‑2G Surface Mount Box for IS‑SS‑2G, IS‑SSR‑2G, IE‑JA, IE‑SS/A, IE‑SSR, LE‑DA, LE‑SS/A or LE‑SSR Specifications Used with: Material KAW‑D: ABS plastic SBX‑DV30, 18AWG stainless  steel Mounting Surface mount directly to wall or 1‑gang box KAW‑D – IX‑BA, IX‑DA, JF‑DA, JK‑DA, JO‑DA, JP‑DA, KB‑DAR, or KB‑DAR‑M SBX‑DV30 – JF‑DV, JK‑DV, JO-DV, or JP‑DV Specifications Used with: • Provides a better viewing angle for the camera • Designed for angle mounting door stations outward by 30° • Applicable for wide or double door entrances Surface Mount Boxes SBX‑DVF Features (KAW‑D) • Provides a better viewing angle for the camera • Compatible with Aiphone 1‑gang surface mount door stations • Angles 1‑gang door stations outward by 30° • Can mount to either right or left of door • Hinged cover for mounting door station Features (SBX‑DV30) Features (SBX‑DVF, SBX‑AXDVF, SBX‑DVF-P, SBX‑ISDVF, SBX-ISDVFP, SBX‑ISDVFRA) SBX‑DVF‑P Surface Mount Box for AX‑DVF‑P, JF‑DVF‑HID, JK‑DVF‑AC, or JK‑DVF‑HID SBX‑ISDVFRA Surface Mount Box for IS‑SS‑CI, IS‑DVF‑2RA, IS‑SS‑2RA, IS‑SS‑2RA‑R, IS‑SS‑RA, IS‑SS‑RA‑R, IX‑DF‑2RA, IX‑SS‑2RA, IX‑SS‑RA, JP‑DVF‑HID, or JP‑DVF‑RP10 • Hood provides weather resistance • Includes space inside for wiring • Mounts directly to wall • Openings at bottom allow for moisture drainage Features (SBX‑1G) • Weather resistant • Includes space inside for wiring • Mounts directly to wall surface Features (SBX‑2G) • Weather resistant • Includes space inside for wiring • Mounts to 1‑gang box or ring • Can mount directly to wall surface • Includes hardware for mounting intercom Material SBX‑DVF‑P, SBX‑ISDVF, SBX‑ISDVFP, SBX‑ISDVFRA, SBX‑1G, SBX‑2G: 18AWG stainless  steel SBX‑DVF, SBX‑AXDVF: 16AWG stainless steel (outer layer) 18AWG stainless steel (inner layer) Mounting SBX‑DVF, SBX‑AXDVF, SBXDVF-P, SBX-ISDVF SBX-ISDVFP, SBXISDVFRA: surface mount directly to wall, 1-gang box, or 2-gang box with included hardware (8 x 32 with T‑15 Torx head) SBX‑1G, SBX‑2G: surface mount directly to wall or 1-gang box with included hardware (8 x 32 with T‑15 Torx head) SBX‑DVF – JF‑DVF, JK‑DVF, JO‑DVF, or JP‑DVF SBX‑AXDVF – AX‑DVF SBX‑DVF‑P – AX‑DVF‑P, JF‑DVF‑HID, or JK‑DVF‑HID SBX‑ISDVF – IS‑DVF, IS‑IPDVF, IS‑SS, IX‑DF, IX‑DF‑HID, IX‑DF‑RP10, or IX‑SS SBX‑ISDVFP – IS‑DVF‑HID, IS‑DVF‑RP10, IS‑IP4DVF, IS‑IPDVF‑HID, or IS‑IPDVF‑RP10 SBX‑ISDVFRA – IS‑SS‑CI, IS‑DVF‑2RA, IS‑SS‑2RA, IS‑SS‑2RA‑R, IS‑SS‑RA, IS‑SS‑RA‑R, IX‑DF‑2RA, IX-SS-2RA, IX-SS-RA, JP‑DVF‑HID, or JP‑DVF‑RP10, SBX‑1G – LE‑SS‑1G SBX‑2G – IS‑SS‑2G, IS‑SSR‑2G, IE‑JA, IE‑SS/A, IE‑SSR, LE‑DA, LE‑SS/A, LE‑SSR, or NI‑JA Accessories Call extension Features Wiring l Announces (chime) call tone only, adjustable l Indoor mounting JP-4MED IER-2 Used for 2 IE series, TC-M JP-4MED, JO-1MD, JO-1FD, JK-1MED, DB-1MD NP S S Unit dimensions 1 E IER-2 29 88 Door release 83.5 120 Call extension Features Wiring l Door release activation, momentary or talk linecontrolled LEF-10C JO-1MD Used for EL-12S Electric door strike DA-1DS, C-123L/A DA-2DS, DA-4DS/G IE-1AD(U), IE-1GD(U) IE-2AD(U), IE-8MD(2) TD-H/B (via DE-UR) LEM-1DL LEF, LEF-C (via RY-PA) JP-4MED, JO-1MD JK-1MED EL-12S EL-12S YL L L BK RY-PA H – L H BK : Black(2) YL : Yellow(2) Specifications (EL-12S) Power source & Consumption 12V AC, 125mA 12V DC, 200mA RY-PA Specifications (RY-PA) Door release relay Relay Power source Relay contact rating Features Used for TD-H/B IE-Series IE-8MD, LEF Wiring LEF-10 LE-D (1) (2) PWR 1 E 1 E – + – T WH YL RD RY-AC/A BK YL (1) External signaling device, bell, etc. (2) Call receive termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow PWR : Power source Unit dimensions RY-AC/A ACCESSORIES Intercom station can be signaled by external device via RY-AC/A relay. External device will be activated momentarily as long as the call signal on the intercom is activated. 12V DC 110V AC, 1A 24V DC, 1A Specifications (RY-AC/A) External signaling relay 62 Power source 104 41 Contact rating 12V DC, supplied by power supply of system or trunk line. 0.3A, 240V AC 1.0A, 24V DC Bell, buzzer, etc. must be AC operated or DC mechanical type only. 98 Power Supplies 16V AC Used for Specifications (16VAC1500/5) DA-1MD, DB-1MD 6V DC Output voltage 16V AC, 1.5A Input voltage & Capacity 230-240V 50Hz Output voltage 6V DC, 0.2A Specifications (PS-1225) Unit dimensions PS-1225 90 240V AC, 50Hz Specifications (6VDC2500/1) Used for C-123L/A, AT-406, LEM, 12V DC Input voltage & Capacity Input voltage & Capacity 100-240V AC, 50/60Hz 37W/6582VA Output voltage 12V DC, 2.5A 167 52 Used for PS-1225 18V DC IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2DU, IE-8MD, LEM-1DL, LEF, LEF-C, TD-H/B, (TC-M) Unit dimensions PS-1820S 90 52 167 ACCESSORIES 99 PS-1820 Used for IE-8MD, JBW-BA, JO-1MD, JO-1FD, JK-1MED TC-M, RY-3DL Specifications (PS-1820) Input voltage & Capacity 100V-240V AC, 50/60Hz, 45W/75-95VA Output voltage 18V DC, 2A 24V DC Unit dimensions Used for YAZ-90-3W, JP-4MED, JP-4HD, JPW-BA, JP-8Z, RY-3DL, MU-100 PS-2420 52 Specifications (PS-2420) 167 90 Input voltage & Capacity 100-240V AC, 50/60Hz 60W/100-125VA Output voltage 24V DC, 2A PS-2420 AIPHONE Approved product wire AIPHONE Wire model name Model AE7090220B AE7090220G AE7090210B AE7090210G AE7120230B AE7090220B AE7090220G AE7090210B AE7090210G AE7120230B Length 200m 200m 100m 100m 300m Gauge a0.9mm a0.9mm a0.9mm a0.9mm a1.2mm Insulation PE PE PE PE PE Jacket color BEIGE GRAY BEIGE GRAY BEIGE Description 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded Recommendation GT GT JK, JO, GT JK, JO, GT JKW-BA, JPW-BA Wire number coding 1st & 2nd Characters 3rd digit 4th & 5th digits 6th & 7th digits 8th & 9th digits 10th Character : Wire Approval : Type of Wire : Gauge : Number of Conductors : Length of Wire : Color of Jacket AE=Aiphone approved wire 7=solid, PE, non-shielded 09=0.9mm diameter, 12=1.2mm diameter 02=2 conductors 10=100 meters box, 20=200 meters box, 30=300 meters box G=Gray, B=Beige Cable printing Printing AIPHONE P/N AE7090220B 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7090220G 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AE7090210B AE7090210G AE7120230B AIPHONE P/N AE7090210B 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7090210G 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7120230B 1.2-2C MADE IN JAPAN YYYY ROHS AIPHONE YYYY: Year of Production : Lead free vinyl USING AIPHONE WIRE EXTENDS YOUR AIPHONE VIDEO PRODUCT WARRANTY BY ONE YEAR. ACCESSORIES Model AE7090220B AE7090220G 100 Communication Distance The below graph is to assist you in determining the diameter of wires or communication distance required. Example; To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires; 1. On the graph; Draw a line from IE-1AD(U) on point A 7.8, crossing the line B at the point 0.8 to reach a point reading 225. A Distance B IE-1AD(U) 0.8 28 225 (m) COMMUNICATION DISTANCE CALCULATION GRAPH SYSTEM & MODELS TB-AD1, AD10 [TC-M] C-123L/A IE-1GD(U) [IEH-1CD] IE-2AD(U) [IEH-1CD] IE-2A2DU [IEH-1C2D] A COMMUNICATION DISTANCE ...m FIXED NUMBER FOR DISTANCE BY ITEM 2,000 3.4 3.9 B IE-1AD(U) [IF-DA] IE-1GD(U) [IF-DA] IE-2AD(U) [IF-DA], IE-2A2DU DE-UR [IF-DA] 7.8 DIAMETER mm 1.6 1.4 1,000 900 800 700 600 10.4 500 0.8 LEM-1, LEM-3 LEF-3, LEF-5 , LEF-10 LEF-10S LEF-3C, LEF-5C, LEF-10C 400 0.65 20.9 26.2 300 0.5 225 200 34.0 36.7 AT-206 [AT-306x3] TC-M [TB-SE] 100 MC-60/4A 90 80 TD-1H, TD-3H, TD-6H TD-12H, TD-24H 70 60 AT-406 50 40 30 20 NOTES; IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station. Video Intercoms are not included in the graph. 101 Compatibility of video intercom system Color video intercom ✓: Compatible Blank: Not Compatible Existing model Door station Sub station Master station JP-DA JP-DV JP-DVF JP-DVF-L JO-1MD JP-4MED Audio door station Video door station JO-DA JO-DV JO-DVF JK-DA JK-DV JK-DVF AX-DV AX-DV-P AX-DVF AX-DVF-P GT-D ✓ ✓ AX-8MV JO-1FD JP-4HD JK-1HD JK-1SD (audio) JPW-BA JKW-BA ✓ ✓ JK-1MED Long distance adaptor Sub master station ✓ ✓ ✓ ✓ ✓ ✓ ✓ AX-8MV requires a central exchange unit. 102 INDEX APAGE AC-10F�������������������������������������������������� 95 AC-10S�������������������������������������������������� 95 AE7090210B��������������������������������������� 100 AE7090210G��������������������������������������� 100 AE7090220B��������������������������������������� 100 AE7090220G��������������������������������������� 100 AE7120230B��������������������������������������� 100 AT-306�������������������������������������������������� 85 AT-406�������������������������������������������������� 85 AT-406B/A��������������������������������������������� 85 AX-084C������������������������������������������� 15,59 AX-16SW������������������������������������������ 16,59 AX-248C������������������������������������������� 15,59 AX-320C������������������������������������������� 15,59 AX-8M���������������������������������������������� 16,59 AX-8MV�������������������������������������������� 16,59 AX-8MV-W��������������������������������������� 16,59 AX-DM���������������������������������������� 15,60,74 AX-DV���������������������������������������������� 15,59 AX-DVF��������������������������������������������� 15,59 AX-DVF-P����������������������������������������� 15,59 AX-DV-P������������������������������������������� 15,59 BPAGE BG-10C������������������������������������������������� 82 CPAGE C-123L/A����������������������������������������������� 69 *3 C-D�������������������������������������������������������� 69 C-ML/A�������������������������������������������������� 69 DPAGE DA-1ASK����������������������������������������������� 67 DA-1DS�������������������������������������������� 64,67 DA-1MD������������������������������������������� 64,67 DA-2DS�������������������������������������������� 65,68 DA-4DG�������������������������������������������� 65,68 DA-4DS�������������������������������������������� 65,68 DAW-P������������������������������������ 64,66,67,68 DB-1MD�������������������������������������� 64,65,85 DB-1SD��������������������������������������� 64,65,85 DBS-1AK����������������������������������������������� 64 DE-UR��������������������������������������������������� 87 EPAGE EL-12S�������������������������������������������������� 98 GPAGE GF-10KP������������������������������������������������ 22 GF-1P���������������������������������������������������� 22 GF-2B���������������������������������������������������� 22 GF-2F���������������������������������������������������� 22 GF-2P���������������������������������������������������� 22 GF-3B���������������������������������������������������� 22 GF-3F���������������������������������������������������� 22 GF-3P���������������������������������������������������� 22 GF-4P���������������������������������������������������� 22 GF-AP���������������������������������������������������� 21 GF-BP���������������������������������������������������� 21 GF-nBA������������������������������������������������� 22 GFW-S��������������������������������������������������� 28 GT-10K�������������������������������������������������� 22 GT-1A���������������������������������������������������� 26 GT-1C���������������������������������������������������� 25 GT-1C-GD���������������������������������������������� 25 GT-1C-SL����������������������������������������������� 25 GT-1C-L������������������������������������������������� 25 GT-1C-L-BK������������������������������������������� 25 GT-1D���������������������������������������������������� 26 103 GT-1M-L������������������������������������������������ 26 GT-2C���������������������������������������������������� 25 GT-2C-L������������������������������������������������� 25 GT-2H���������������������������������������������������� 25 GT-2H-L������������������������������������������������� 25 GT-4B���������������������������������������������������� 22 GT-4F���������������������������������������������������� 22 GT-4Z���������������������������������������������������� 28 GT-AC���������������������������������������������������� 21 GT-AD���������������������������������������������������� 21 GT-BC���������������������������������������������������� 28 GT-BCX�������������������������������������������������� 29 GT-D������������������������������������������������������ 27 GT-DA���������������������������������������������������� 21 GT-DA-L������������������������������������������������ 21 GT-DM��������������������������������������������������� 21 GT-DP���������������������������������������������������� 21 GT-DP-L������������������������������������������������ 21 GT-HID��������������������������������������������������� 21 GT-HS���������������������������������������������������� 25 GT-MK��������������������������������������������������� 28 GT-nH���������������������������������������������������� 22 GT-nHB�������������������������������������������������� 22 GT-NS���������������������������������������������������� 22 GT-NSP-L���������������������������������������������� 22 GT-RY���������������������������������������������������� 29 GT-SW��������������������������������������������������� 22 GT-VA���������������������������������������������������� 21 GT-VBC�������������������������������������������������� 28 GT-VBX�������������������������������������������������� 29 GT-VP���������������������������������������������������� 21 GTW-LC������������������������������������������������� 30 IPAGE IAI-100�������������������������������������������������� 90 IAX-100������������������������������������������������� 90 IE-1AD(U)���������������������������������������������� 70 IE-1GD(U)���������������������������������������������� 71 IE-2A2DU���������������������������������������������� 72 IE-2AD(U)���������������������������������������������� 72 IE-8HD�������������������������������������������������� 73 IE-8MD�������������������������������������������������� 73 IE-SS/A������������������������������������������������� 74 IEH-1C2D���������������������������������������������� 72 IEH-1CD������������������������������������������� 71,72 IE-JA����������������������������������������������������� 72 IER-2����������������������������������������������������� 98 IF-DA����������������������������������������������������� 87 IME-100������������������������������������������������ 89 IME-150������������������������������������������������ 90 IMU-100������������������������������������������������ 89 IS-CCU�������������������������������������������������� 59 IS-DV����������������������������������������������������� 55 IS-DVF��������������������������������������������������� 55 IS-IPC���������������������������������������������������� 54 IS-IPDV�������������������������������������������������� 53 IS-IPDVF������������������������������������������������ 53 IS-IPMV������������������������������������������������� 53 IS-MV���������������������������������������������������� 55 IS-PU-S������������������������������������������������� 58 IS-RCU�������������������������������������������������� 56 IS-RS����������������������������������������������������� 56 IS-SCU�������������������������������������������������� 56 IS-SOFT������������������������������������������������� 54 IS-SS����������������������������������������������������� 56 IS-SS-2G����������������������������������������������� 56 IS-DVF��������������������������������������������������� 55 ISE-100������������������������������������������������� 90 IS-WBCA����������������������������������������������� 45 IS-WBCE����������������������������������������������� 45 IS-WBHA����������������������������������������������� 45 IS-WBHE����������������������������������������������� 45 IX-1AS��������������������������������������������������� 46 IX-10AS������������������������������������������������� 46 IX-BA����������������������������������������������������� 43 IX-DA����������������������������������������������������� 44 IX-DF����������������������������������������������������� 44 IX-DF-2RA��������������������������������������������� 45 IX-DF-P������������������������������������������������� 44 IX-DF-PI������������������������������������������������ 44 IX-MV���������������������������������������������������� 43 IX-SS����������������������������������������������������� 43 IX-SS-RA����������������������������������������������� 45 IX-SS-2RA��������������������������������������������� 45 JPAGE JF-2HD�������������������������������������������������� 14 JF-2MED����������������������������������������������� 13 JF-2SD�������������������������������������������������� 14 JF-D������������������������������������������������������ 13 JF-DA���������������������������������������������������� 13 JF-DV���������������������������������������������������� 13 JF-DVF�������������������������������������������������� 13 JFS-2AED���������������������������������������������� 14 JFS-2AEDV�������������������������������������������� 14 JFS-2AEDF�������������������������������������������� 14 JK-1HD������������������������������������������������� 10 JK-1MED������������������������������������������������� 9 JK-1SD�������������������������������������������������� 10 JK-DA������������������������������������������������� 9,27 JK-DV������������������������������������������������� 9,27 JK-DVF����������������������������������������������� 9,27 JK-DVF-AC�������������������������������������������� 10 JKS-1ADF��������������������������������������������� 10 JKS-1AED��������������������������������������������� 10 JKS-1AEDF������������������������������������������� 10 JKS-1AEDV������������������������������������������� 10 JKW-BA������������������������������������������������� 11 JKW-IP�������������������������������������������������� 12 JO-1MD��������������������������������������������������� 8 JO-1FD���������������������������������������������������� 7 JO-DVF���������������������������������������������������� 7 JO-DV������������������������������������������������������ 7 JO-DA����������������������������������������������������� 7 JOS-1A���������������������������������������������������� 8 JOS-1F���������������������������������������������������� 8 JOS-1V���������������������������������������������������� 8 JP-4HD���������������������������������������������� 4,78 JP-4MED�������������������������������������������� 3,77 JP-8Z������������������������������������������������� 4,78 JP-DA������������������������������������������������� 3,77 JP-DV������������������������������������������������� 3,77 JP-DVF����������������������������������������������� 3,77 JP-DVF-L�������������������������������������������� 3,77 JPEC������������������������������������������������������� 4 JPS-4AED����������������������������������������������� 4 JPS-4AEDF���������������������������������������������� 4 JPS-4AEDV��������������������������������������������� 4 JPTIIP������������������������������������������������������ 3 JPW-BA��������������������������������������������������� 6 Jx-DVF-AC������������������������������������������� 4,8 KPAGE KAW-D��������������������������������������������������� 97 LPAGE LE-A������������������������������������������������������ 84 LE-AN���������������������������������������������������� 84 LE-D������������������������������������������������������ 84 LE-DA��������������������������������������������������� 84 LE-DL��������������������������������������������������� 84 LEF-10������������������������������������������������� 81 LEF-10C����������������������������������������������� 83 LEF-10S����������������������������������������������� 81 LEF-10W���������������������������������������������� 81 LEF-1C�������������������������������������������� 83,84 LEF-3��������������������������������������������������� 81 LEF-3C������������������������������������������������� 83 LEF-3L������������������������������������������������� 81 LEF-5W������������������������������������������������ 81 LEM-1�������������������������������������������������� 80 LEM-1DL���������������������������������������������� 79 LEM-3�������������������������������������������������� 80 LE-SS-1G��������������������������������������������� 84 LE-SS/A����������������������������������������������� 84 LEW-10������������������������������������������������ 82 LEW-10S���������������������������������������������� 82 LEW-5�������������������������������������������������� 82 TOWER������������������������������������������������� 45 WPAGE W-DIN11���������������������������������������������� 29 YPAGE YAW-RB������������������������������������������������ 86 YAZ-90-3W������������������������������������������� 86 *3 Not available separately MPAGE MC-60/4A�������������������������������������������� 94 MC-A/A������������������������������������������������ 94 PPAGE PD-1����������������������������������������������������� 88 PD-2����������������������������������������������������� 88 6VDC2500/1����������������������������������������� 99 PS-1225����������������������������������������������� 99 PS-1820����������������������������������������������� 99 PS-2420����������������������������������� 29,58,100 16VAC1500/5��������������������������������������� 99 RPAGE RY-3DL��������������������������������������������������� 6 RY-AC/A����������������������������������������������� 98 RY-ES��������������������������������������������������� 75 RY-IP44������������������������������������������������ 46 RY-PA��������������������������������������������������� 98 SPAGE SBX-1G������������������������������������������������ 97 SBX-2G������������������������������������������������ 97 SBX-AXDVF������������������������������������������ 97 SBX-DV30�������������������������������������������� 97 SBX-DVF���������������������������������������������� 97 SBX-DVF-P������������������������������������������� 97 SBX-GTDM������������������������������������������� 22 SBX-ISDVF�������������������������������������� 46,97 SBX-ISDVFP����������������������������������������� 97 SBX-ISDVFRA���������������������������������� 46,97 TPAGE TB-AD1������������������������������������������������ 93 TB-AD10���������������������������������������������� 93 TB-SE��������������������������������������������������� 92 TC-10M������������������������������������������� 91,93 TC-20G������������������������������������������������� 92 TC-20M������������������������������������������������ 91 TC-40G������������������������������������������������� 92 TC-40GS����������������������������������������������� 92 TD-12H/B��������������������������������������������� 88 TD-1H/B����������������������������������������������� 87 TD-24H/B��������������������������������������������� 88 TD-3H/B����������������������������������������������� 87 TD-6H/B����������������������������������������������� 87 TDW-1/A���������������������������������������������� 88 TDW-12/A�������������������������������������������� 88 TDW-24/A�������������������������������������������� 88 TDW-3/A���������������������������������������������� 88 TDW-6/A���������������������������������������������� 88 104 ISO 14001 ISO 9001 ISO 14001 Certified ISO 9001 Certified JQA-EM0453 Headquarters section Toyota Factory Taiho Site AIPHONE CO., LTD. JQA-0291 Deming Prize Deming Medal AIPHONE CO., LTD. AIPHONE PTY LTD Unit 11A, 2 Eden Park Drive Macquarie Park, NSW 2113 Australia Tel.: 02-8036-4507 URL: http://www.aiphonepty.com.au/ GLC2015-16(AU) Pr i nt ed i n J apan AZ57058AJZ