Transcript
Communication Systems
GENERAL LINE CATALOGUE 2016
C
o
n
COLOR VIDEO ENTRY SECURITY
DOOR
ROOM
4 8
DOOR
ROOM
1 2
DOOR
ROOM
1 2
DOOR
7-inch Touchscreen Color Video Intercom
JP-4MED
Wide and Zoom & PanTilt Hands-free Color Video Intercom
MASTER
PC
IP color video Intercom adaptor
Max.20
ROOM
2 3
MASTER
DOOR
12
IX SYSTEM
Security IP Video Intercom System
IS SYSTEM
JF-2MED
13
DOOR
Hands-free Color Video Intercom
15
ROOM
1 5 1 4
DOOR
Hands-free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt features
GT SYSTEM
ENTRANCE TENANT
17~33 17
System outline ENTRANCE TENANT
5 48 Standard System Configuration
19
ENTRANCE TENANT
16 500 Expanded System Configuration Entrance station Tenant station Video door station, Door station Security guard station, Control units Expanded control units, Power supply, Option GT Lift control adaptor Cabling (standard) Wiring (standard) Compatibility with the existing system
Example
2
DOOR ENTRANCE MASTER SERVICE SIDE STATION
3
ROOM TENANT SUB PUBLIC SIDE
ROOM
1 1
MULTI-TENANT BUILDING ENTRY SECURITY
20 21 25 27 28 29 30 31 32 33
s 35 47 59
AUDIO ENTRY SECURITY
ENTRANCE TENANT
8 120 AX
Integratable Audio & Video Security
8 120 AX
DOOR
Hands-free Color Video Intercom, Picture Memory
t
IP Network Audio-Video Intercom System
MASTER
9
n
INTEGRATED SECURITY & COMMUNICATION SYSTEM
7
JO-1MD
JK-1MED
e
3
7-inch Screen Color Video Intercom
1 1 10 JKW-IP
DOOR
t
1 4
DOOR
ROOM
DOOR
ROOM
DOOR
ROOM
DOOR
ROOM
1 1 1 3 2 3 2 6
Hands-free Two-Wire Electric Lock Door Phone
DB-1MD
Hands-free Two-Wire Electric Lock Door Phone
DA-4DS with DB-1MD
Two-Wire Electric Lock Door Phone
DA-1AS
Two-Wire Electric Lock Door Phone
DA-4DS
Chime Tone Intercom
C-123L/A
Chime Tone Intercom
IE-1GD(U)
Chime Tone Intercom
IE-2A2DU
Chime Tone Intercom
64 65 67 68 69 71 72
IE-8MD
73
Audio Door Stations and Accessories
74
INTERCOM SYSTEM DOOR
ROOM
DOOR
ROOM
MASTER
SUB
4 8 1 1 1 3
STATION
JP-4MED
Open Voice Intercom
LEM-1DL
Open Voice Intercom
LEM
Open Voice Intercom
11 DOOR
7-inch Touchscreen Color Video Intercom
LEF ROOM
3 8
MASTER
SUB
MASTER
SUB
1 4 1 3
STATION
Open Voice Intercom
84
DB-1MD
Handset Intercom
AT-406
Handset Intercom
25
TD-H/B
SERVICE SIDE PUBLIC SIDE
1 1
81
LE Sub stations & Accessories
YAZ-90-3W
STATION
80
83
Hands-free Intercom
Security Window Intercom
85 86 87 89
/ Sub Intercom 2 100 Master TC-M
91
SUB
DOOR
ROOM
10 1
STATION
60
Master / Sub Intercom
TC-M & TB-AD10 Market-Com
MC-60/4A
94
AUDIO ENTRY SECURITY
AC-10S, AC-10F
95
Angle + Surface Mount Boxes
97
Accessories
Accessories
IER-2, EL-12S, RY-PA, RY-AC/A Power Supplies AIPHONE Approved product wire
INTEGRATED SECURITY & COMMUNICATION SYSTEM
93
ACCESSORIES Access Control
MULTI-TENANT BUILDING ENTRY SECURITY
85
IMU-100
MASTER
COLOR VIDEO ENTRY SECURITY
79
LEF-C
Handset Intercom
90
77
98 99 100
COMMUNICATION DISTANCE & INDEX Communication Distance Compatibility of video intercom system INDEX
101 102 103
INTERCOM SYSTEM
ACCESSORIES
Communication Systems for business, home and industry Established In 1948 Aiphone has become the most respected and reliable brand of communication systems in the world. With headquarters in Nagoya and manufacturing in Toyota City, Central Japan, we export to over 60 countries. We expand ourselves along with a North American marketing, sales and distribution center near Seattle, Washington, and an European sales and distribution center in Lisses-Evry, France.
Systems For Every Application Aiphone products range from simple do-it-yourself door answering units to sophisticated video entry security systems, complex microprocessor-based commercial systems, and luxury condo/apartment security/communication systems. They are unrivaled in design simplicity, technical excellence and reliability. With over 30 standard systems, and additional manufacturing by special order, we can create a system for virtually any intercom application.
Designed To Last Every Aiphone system is the result of painstaking attention to detail: contemporary European style design, the finest quality hardware and circuitry, engineered, built and 100% pre-tested for sustained trouble-free service.
AIPHONE CO., LTD. in Japan Headquarters
Toyota factory
ISO 9001 Aiphone is the first intercom manufacturer worldwide to receive ISO 9001 certification, and the only one selling in North America, An agency representing the International Standards Organization (ISO), headquartered in Geneva, Switzerland, graded Aiphone against guidelines for design and development, production, and product inspection and testing. ISO 9001 standards provide an immediate recognition of product quality almost anywhere in the world.
ISO 9001 Certified JQA-0291
AIPHONE CO., LTD.
Winner Of The Deming Prize Aiphone is the first and only intercom manufacturer to win the Deming Prize, the highest international award for quality control. Named in honor of Dr. W. Edwards Deming, the award honors firms worldwide which advance and maintain manufacturing quality. Deming Prize
Acquisition of ISO 14001 ISO's Environmental Standards are a series of voluntary standards and guideline reference documents which include environmental management systems, eco-labeling, environmental auditing, life cycle assessment, environmental performance evaluation, and environmental aspects in products standards. In early 1998, our management team determined to acquire ISO-14001 approval as a company-wide project, and working committee was established at the same time. Since then, with our ongoing efforts and practice about environmental management standards, we have succeeded to acquire the approval. Aiphone excludes the use of prohibited material from the product according to RoHS directive (2002/95/EC). Therefore, as of July 1, 2006, all the Aiphone products imported in EU will be fully complied with the RoHS directive.
AIPHONE CORPORATION in USA
AIPHONE S.A.S. in France
ISO 14001 Certified JQA-EM0453 Headquarters section Toyota Factory Taiho Site
AIPHONE CO., LTD.
ENVIRONMENTAL REPORT We will contribute to building a sustainable society while cultivating communications with a wide spectrum of our stakeholders. Basic Environmental Philosophy
Revised October 1, 2005
Based on our business philosophy of "Be Responsible for your job and don't cause of problems for others," we carry out our activities while harmonizing conservation of the global environment with our business operations.
Environmental Policy
The AIPHONE group aspires to be enterprises capable of making contributions to society by using communication and security technologies, conducting our environmental activities as follows: (1) We will strive to minimize environmental loads to conserve the global environment in our activities of developing, producing, selling, and servicing our products. (2) We will make our goals and objectives clear in our business activities, continuously evaluating the following items and thus improving them: a) We will aim to become a recycling society and make efforts to promote the 3R's (Reduce, Reuse, and Recycle) and minimize waste. b) We will not use harmful substances that cause environmental contamination. c) We will strive to conserve energy to prevent global warming. (3) We will conform to environment-related laws, regulations, and conventions while establishing voluntary standards to conserve the environment. (4) Placing great value on communication, we will promote the manufacture of products friendly to both humans and the environment. (5) We will conduct environmental audits in an effort to maintain and improve our environment management system. (6) We will make our environmental policy thoroughly known to our employees and all those who work together with us. (7) We will publicize this environmental policy to the general public.
Certificate of acquisition of lSO 14001 accreditation
This report is also posted on our website:
http://www.aiphone.net
Lineup Aiphone provides you with a variety of security systems and intercoms from small to extensive IP network systems, so that you can choose the perfect solution for your security needs.
COLOR VIDEO ENTRY SECURITY
P1~
MULTI-TENANT BUILDING ENTRY SECURITY
P17~
INTEGRATED A SECURITY & COMMUNICATION SYSTEM
P34~
AUDIO ENTRY SECURITY
P63~
INTERCOM SYSTEM
P76~
COLOR VIDEO ENTRY SECURITY 7-inch display
COLOR VIDEO ENTRY SECURITY
7-inch display
1
The JP Series and JO Series intercoms feature a large 7-inch display for clear visitor identification. COLOR VIDEO ENTRY SECURITY
7inch
Actual size (JO series)
JP Series
JO Series
Touchscreen
Non-mechanical touch buttons
Oversized buttons and intuitive icons allow for quick navigation and control.
Quick & easy icons simply require a light touch to operate the intercom.
Multi-station, multi-function type
Simple type
Lineup
7-inch Touchscreen Color Video Intercom
7-inch Screen Color Video Intercom
Wide and Zoom & PanTilt Hands-free Color Video Intercom
Hands-free Color Video intercom,Picture Memory
Hands-free Color Video Intercom
JP-4MED
JO-1MD
JK-1MED
JF-2MED
AX
13
5
2
7-inch Touchscreen Color Video Intercom DOOR
Features
ROOM
• • • • •
8 JP-4MED
4
7-inch touchscreen for operation Hands-free or handset audio communication Zoom/wide and pan & tilt video monitoring function Video image adjusting function Record visitor images both automatically & manually
Door station
Master station 2
COLOR VIDEO ENTRY SECURITY
2 Cat5e
2 2 2
JP-DV
Wide and Zoom & PanTilt Vandal resistant video door station, surface mount
2
2
2
3 connectors
2
2
PT
JP-4MED
PS24
Hands-free color video intercom master station
RY-3DL
Multiple door release adaptor
or
GT-D
Audio door station
JP-DA
JP-DVF*
Handsfree module for JP-4MED & JP-4HD
JP-DVF-L
Wide and Zoom & PanTilt video door station, surface mount
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount
JPEC
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount (Guidance-enabled type)
JPTLIIP
Power supply PS-2420 P.100
IP Interface for JP System (compatible with iOS and Android)
* Marine grade option available
The wide monitor clearly shows all 170 degrees of video captured by the camera
The JP Series 170° wide angle and 100° vertical angle camera minimizes blind spots, ensuring a clear view of the door station area.
Focus on a particular area for more detail. Zoom
Using the touchscreen, zoom into visitor faces and other specific areas.
Tall viewing height : Approx.
100°
Touch
PanTilt
WIDE IMAGE
ZOOM IMAGE
Using the PanTilt function, view details such as ID badges or labels.
Video door station
Wide viewing area : Approx.
170°
High image quality provides a clear view of detailed areas.
Touch
ZOOM IMAGE
Communication network JP-DV
(Master station) JP-4MED
The design and specifications are subject to change without notice for improvement.
3
PANTILT IMAGE
JP-4HD (Sub master station) JP-4HD
x7 JP-4HD
JP-4HD
JP-4HD
• 3 wiring methods selectable (Station-to-station, Homerun, or combined wiring) • 2 internal calls selectable (All call or Individual call) • Audio monitoring of other master stations • Option: 3 sensors connectable to the master station Commercial
Residential
Retail Shops
Factories
Schools
Sub master station
JP-4HD
JP-4HD Cat5e
Cat5e
JP-4HD Cat5e
PS24
JP-4HD
Cat5e
Hands-free color video intercom sub master station
JP-4HD
Boxed sets
JP-4HD Cat5e
JPS-4AED: JP-4MED, JP-DA, PS-2420 JPS-4AEDV: JP-4MED, JP-DV, PS-2420 JPS-4AEDF: JP-4MED, JP-DVF, PS-2420
Access Control P.99
Lineup
AC-10S
JPW-BA
Jx-DVF-AC
Access control keypad, surface mount
JP-DV + AC-10S
Unit dimensions JP-DV
97
309
28.5
83.5
IER-2
5 45
135 RY-3DL
45
Video monitor Pixels Video output Night viewing
140
130
55
117
30
98
33
132
5.6
98 AC-10F
120
45
27
GT-D
100
144
150
98
68.5
125
295
AC-10S
JP-DVF-L
209
30.5
8
25
Power source Power supply Consumption Calling Communication
5.6
88
29
74 JP-8Z
Door release Option output Wiring
42
109
48
JP-DVF
173
129
JP-DA
145
255
Distribution adaptor
EL-12S
Electric door strike P.98
RY-3DL
Multiple door release adaptor P.6
Specifications (JP-4MED,JP-4HD)
JP-4MED, JP-4HD
Jx-DVF-AC
JP-8Z
Long distance adaptor P.6
Jx-DVF-AC + JP-DVF
PS24
COLOR VIDEO ENTRY SECURITY
Cat5e
JP-4HD
123
Wiring distance ( P.5)
61
24V DC PS-2420 Max. 340mA(JP-4MED). Max. 200mA (JP-4HD) Chime. Image & audio, approx. 45 or 90 sec. Automatic(Hands-free): approx. 1 min. To activate, touch TALK button. Handset: approx. 3 min. To activate, lift handset. 7-inch color LCD screen 1,150,000 pixels NTSC/PAL, 1Vp-p/75 Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: CAT5e Door to Master: 100m (1.0mm) Master to farthest sub: 300m(CAT5e)
45
Image view area (* ) For JP-DVF-L
JP-DA, JP-DV, JP-DVF, JP-DVF-L
(WIDE)
(WIDE)
(ZOOM)
approx. 170˚
(ZOOM)
approx. 220cm(*225)
approx. 185cm(*190)
approx. 130cm approx. 130cm
approx. 125cm(*130)
approx. 90cm(*95)
approx. 60cm 150cm approx. 95cm
approx. 60cm
50cm
150cm
50cm approx. 85˚ approx. 95 cm
50cm
4
7-inch Touchscreen Color Video Intercom Wiring Station-to-Station Wiring
(Daisy-chain Wiring) Cumulative total wiring distance (using CAT5e cables): Max. 300m
[A]
[E] JP-DV
JP-4MED
2
[B]
JP-4HD
JP-4HD
JP-4HD
COLOR VIDEO ENTRY SECURITY
2
A1 A2
[B]
JP-4HD
[C]
JP-4HD
JP-4HD
2
PS24
[F]
Door station 1
([A]x2)+([B]x2)+[C]=Max.300m
[A]
2
PS24
[F]
JP-4HD
PS24
[F]
M(OUT)
M (IN)
M(OUT)
M (IN)
M(OUT)
M (IN)
M(OUT)
M (IN)
1A1 1A2 2A1 2A2 3A1 3A2 4A1 4A2
M(OUT)
M (IN)
M(OUT)
M (IN)
M(OUT)
M (IN)
M(OUT)
Door station 2 Door station 3 Door station 4 *Same as door station 1.
b1 b2 b3 b4
EL-12S
S S
L1 L1
EL-12S
PS24
4-pin option connector Yellow Orange Door station selecting signal output Red Brown
PS24
l [A], [C]: A single power supply can power up to 1 master and 2 sub master stations, or 3 sub master stations. The wiring distance varies depending on the number of powered room stations. l See “Wiring distance between each device” below for the maximum distance between each device. : CAT5e
1 E IER-2
L2 L2
12-pin option connector Black Security/Utility input specification Purple Security/Utility input 3, External talk input Input method N/O or N/C dry closure contact (start signal only detection method) Black Detection confirmation time 100 mS or more Security/Utility input 2, Yellow Contact resistance During N/O dry closure: Less than 700d Black During N/C dry closure: more than 15Kd Security/Utility input 1, Terminal short current Less than 10 mA Orange Less than 5V DC Voltage between terminals Black (when open between terminals) Option output Gray (AC/DC 24V, 1A, N/O dry closure contact) White (Unused) Blue Red Brown Video signal output
S3E S3 S2E S2 S1E S1 SW SW
PT
VV+
(NTSC/PAL, 1Vp-p/75d)
PS24
Centralized Wiring (Homerun Wiring)
JP-DV etc.
Cumulative total wiring distance (using CAT5e cables): Max. 300m [B]+([D]x7)=Max.300m JP-4HD
JP-4HD
JP-4HD
JP-4HD
[E] 2
[B]
JP-4MED
[D]
2
2
[D]
[D]
[D]
[D]
JP-4HD
JP-8Z [F] (*1)
2
[G]
PS24
(*2)
2
PS24
[D]
2
[D]
PS24
2
JP-4HD JP-4HD (*1): The master station requires a power supply. (*2): Up to 4 sub master stations can be powered with one power supply. Use two power supplies for 5 - 7 sub master stations. See “Wiring distance between each device” on the right for the maximum distance between each device.
Combined Wiring
Cumulative total wiring distance (using CAT5e cables): Max. 300m [A]+([B]x2)+([D]x4)=Max.300m JP-4HD
JP-DV etc.
JP-4HD
[E] [B]
2
JP-4MED
[A] JP-4HD
JP-4HD
[B] JP-4HD
Wiring distance between each device [D]
[D]
2
2
[D]
JP-8Z [F]
2
PS24
[F]
2
[G]
PS24
[D]
2
5
Notes CAT5e 30m When 3 room stations are powered by a single power supply 200m 50m When 2 room stations are powered by a single power supply 50m Wire diameter (PE cable) Ø0.65 mm Ø0.8 mm Ø1.0 mm Ø1.2 mm
JP-4HD
H : AC transformer N : PS-2420
[A] [B] [C] [D]
PS24
2
See “Wiring distance between each device” on the right for the maximum distance between each device.
JP-4HD
[E] [F] [G]
50m 5m 5m
100m 5m 10m
100m 10m 10m
100m 10m 10m
Long distance adaptor Wiring When extending the distance between the master station and a door station Max: 600m Door to the farthest sub master station Max. 300m Cumulative total wiring distance (using CAT5e cables): Max. 300m [c]
[b]
JP-DV
JPW-BA
JP-4MED
2 [c]
2
2
PS24
[a]
JPW-BA
A1 A2
Long distance adaptor
Features • When JP series door station is more than 100m to max. 300m away. • CCTV camera can be integrated by connecting JPW-BA.
A1 A2 ON OFF
B1 B2
PAL NTSC Door Station
[c]
Max. 15m Coaxial cable Coax
CCTV camera
GT-D
JPW-BA
2 [c]
2
2
PS24
[a] VIDEO INPUT
Coax
1 2
61
: CAT5e
JP-4MED
2
VIDEO OUTPUT
109
M(OUT)
PS24
[b]
JPW-BA
M (IN)
M(OUT)
1A1 1A2
When connecting a third-party CCTV camera and an audio door station in place of a video door station.
Unit dimensions
123
JP-4HD
COLOR VIDEO ENTRY SECURITY
2
B1 B2
1A1 1A2
M(OUT)
A1 A2
ON OFF
When this switch is set to either “NTSC” or “PAL”, the Zoom / Wide and Pan & Tilt function are disabled.
PS24
PAL NTSC Door Station
Wiring distance between each device
Specifications
Wire diameter (PE cable) Ø0.65 mm Ø0.8 mm Ø1.0 mm Ø1.2 mm 5m 5m 10m 10m [a] 150m 200m 200m [b] 100m 50m 75m 100m 100m [c]
Power source
24VDC, PS-2420 of system or separate Current consumption MAX. 90mA Wiring 2 parallel wires to ea. door & master.
Selective door release adaptor
Wiring
Features
Door station 1 JP-DV etc.
• Selective door release with one button • Door release contacts release the door where communication is established. • Normally open contacts for electric strike. Normally closed contacts to work with magnetic locks.
JP-4MED
A1 A2
1A1 1A2 2A1
Used for
JP-4MED
RY-3DL
Electric door strike 1
Unit dimensions
Door release adaptor
L1 L1
EL-12S
RY-3DL 140
RY-3DL
74
Electric door strike 2 42
Electric door strike 3
Specifications Power source Power supply Relay contacts Wiring distance
EL-12S
12~24V DC, 30mA 12~16V AC, 60mA PS-2420; PS-1820; PS-1225; AC trans. Normally open output. 1A at 50V AC. 1A at 30V DC (for other types, use matching relay) Master to RY-3DL 50m(0.65mma) 100m(1.0mma) RY-3DL to EL-12S 50m(0.65mma) 100m(1.0mma)
EL-12S Electric door strike 4
EL-12S
PT
L1 C1 /L1
b1 b2 b3
L2 C2 /L2
L E
L3 C3 /L3
H : AC transformer N : PS-2420
4-pin option connector
b1 Brown b2 Red b3 Orange b4 Yellow
4 pin option connector identifies active door. b1 is brown lead, active with door 1. b2 is red lead, active with door 2.
L2 L2
b3 is orange lead, active with door 3. b4 is yellow lead, active with door 4.
PS24
6
7-inch Screen Color Video Intercom DOOR
ROOM
2 JO-1MD
1
Door station
Expansion monitor station
COLOR VIDEO ENTRY SECURITY
2
4
2
JO-1FD
JO-DV
Vandal resistant video door station, surface mount
PS18
Expansion monitor station
IER-2
Call extension m P.98
or
2 PT
or
JO-DA
JO-DVF *
Video door station, surface mount
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount
Power supply PS-1820
m P.99
Features • • • • •
Total hands-free communication Video image adjusting function Room to room communication is not available Easy operation by buttons with picture indications Option output: Option button connectable to the master station and expansion monitor station.
Wiring JO-DV
100m/1.0mmØ
JO-1FD
100m/1.0mmØ
2
JO-1MD
4 2 PS18
7-inch screen
View images more clearly with 7-inch screen!
EL-12S
2
7-inch size DOOR MASTER
A1 A2
A1 A2
B1 B2
CALL EXT
S S
The conventional size
DOOR
IER-2
1 E
OUT
DC18V
Control buttons
A1 A2 CALL EXT
S S
IER-2
1 E
DC18V
IN
DC18V
Volume control button
PS18
Monitor button Option button
OPTION SW SW
EL-12S
Screen brightness control button
DOOR RELEASE
L L
Door release button Talk/off button The design and specifications are subject to change without notice for improvement.
7
PT
Option units
OPTION SW SW DOOR RELEASE
L L
Option units
Commercial
Residential
Master station
COLOR VIDEO ENTRY SECURITY
Boxed sets
2 Standard
JO-1MD
Master station
IER-2
Call extension m P.98
Lineup
Access Control m P.95
AC-10S
Access control keypad, surface mount
Communication network
Jx-DVF-AC
Jx-DVF-AC + JO-DVF
EL-12S JO-DV + AC-10S
JO-1MD
Power source Power supply Consumption Calling Communication
M
Video monitor Pixels Night viewing
JO-1FD
(Expansion monitor station)
Unit dimensions
295
230
3.3
J0-DVF
209
130
8
JO-DV
Wiring distance
21
JO-DA 129
144
AC-10S
83.5
120
88
29
25.5
33
approx. 55cm
100
132
117
5
AIPHONE approved product wire m P.100
approx. 175cm
JO-DA, JO-DV, JO-DVF
98
AE7090210B AE7090210G
18V DC PS-1820 Max. 440mA(JO-1MD). Max. 460mA (JO-1FD) Chime. Image, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 2 sec. or more. 7-inch color LCD screen 1,150,000 pixels "Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 0.5A (N/O dry closure contact) Door to master (or Expansion monitor) : 2-cond., mid cap solid, non-shielded. Expansion monitor to Master : 4-cond., mid cap, solid, non-shielded. Door to Master(or Expansion monitor station): 100m (1.0mmØ) Expansion monitor to master monitor station : 100m (1.0mmØ) Monitor station to IER-2: 150m(1.0mmØ)
Image view area
AC-10F
36
125
IER-2
25
98
45
135
45
55 68.5
97
26.8
Door release Option output Wiring
173
Jx-DVF-AC
Electric door strike m P.98
Specifications
(Master station)
JO-DV
JO-1FD, JO-1MD
JOS-1A: JO-1MD, JO-DA, PS-2420 JOS-1V: JO-1MD, JO-DV, PS-2420 JOS-1F: JO-1MD, JO-DVF, PS-2420
45
approx. 145cm
approx. 50cm
approx. 120cm
approx. 50cm approx. 95cm
8
Wide and Zoom & PanTilt Hands-free Color Video Intercom DOOR
ROOM
2 JK-1MED
1
Door station
Master station Picture memory
COLOR VIDEO ENTRY SECURITY
4
2
2
2 PT
JK-DV
Wide and Zoom & PanTilt Vandal resistant video door station, surface mount or
IER-2
Call extension m P.98
PS18
JK-1MED
Master station w/Wide and Zoom & PanTilt color monitor & built-in picture memory.
or
JK-DA
JK-DVF
Wide and Zoom & PanTilt video door station, surface mount
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount
Power supply PS-1820
m P.99
Features
• Total hands-free communication, auto-voice actuation • Visual monitoring with audio for 1 minute • Instant voice call-in with image • Press-to-talk operation available • Press-to-talk restriction • White LED illumination turns on in low-light conditions • Video image adjusting function • Full color video in low light situations w/o external illumination • Camera angle preset • External input • Option - Option button, press-to-talk setting, video signal output
PANORAMIC WIDE View
Everyone at the entrance can be identified by image from JK wide angle camera. The field of vision can be controled on Wide mode or Zoom mode from inside.
WIDE IMAGE
ZOOM IMAGE
Zoom & PanTilt
Communication network (Master station)
By pressing PanTilt button, the image of the PanTilt video door station can be adjusted to a more visible position from inside on the Zoom mode.
JK-1MED
JK-DV
M
WIDE IMAGE
PanTilt on Zoom mode
*The screen images are simulated graphics. They are images to express functions, and are different from the real one. Please understand it beforehand.
or JK-1SD JK-1HD
(Sub master station) The design and specifications are subject to change without notice for improvement.
9
Lineup
Sub master station
JK-1SD
Audio sub master station
JKW-BA
EL-12S
JKW-IP
JK-DVF-AC
Long distance adaptor m P.11 *Max. 300m away from Master/sub to Door.
JK-1HD
Sub master station w/color monitor
Electric door strike m P.98
Boxed sets
IP color video intercom adaptor m P.12
Access Control m P.95
Vandal resistant color video door station with access control keypad
Picture memory
AC-10S
AC-10F
Specifications JK-DV
98
27
295
88
45
98
33
132
29
Image view area
Video monitor Scanning line Video output Night viewing Door release Option output Wiring
AC-10F 83.5
120
45
135
55 68.5
125 35.5
IER-2
144
25
AC-10S
Power source Power supply Consumption Calling Communication
25
JK-DA
97
8
100
8
JK-DVF
209
185 80
129
JK-DVF-AC
27
29.5
173
JK-1SD
185 135
AIPHONE approved product wire m P.100
JK-DV + AC-10S
Unit dimensions JK-1MED, JK-1HD
AE7090210B AE7090210G
JKS-1AED: JK-1MED, JK-DA, PS-2420 JKS-1AEDV: JK-1MED, JK-DV, PS-2420 JKS-1AEDF: JK-1MED, JK-DVF, PS-2420
Access control keypad, flush mount
Access control keypad, surface mount
COLOR VIDEO ENTRY SECURITY
4
or
117
5
Wire type Wiring distance
45
18V DC PS-1820 Max. 400mA (JK-1MED). Max. 200mA (JK-1HD). Max. 120mA (JK-1SD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3.5-inch direct-view TFT color LCD. 525 lines NTSC, 1Vp-p/75 Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1.6A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. AIPHONE approved product wire: AE7090210B, AE7090210G Master/sub to door: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma)
JK-DA, JK-DV, JK-DVF (WIDE)
(ZOOM)
(WIDE)
approx. 170˚
(ZOOM & PanTilt) approx. 225cm approx. 85cm
approx. 200cm
approx. 70cm
approx. 105cm approx. 105cm
approx. 70cm
approx. 95cm 150cm
approx. 90cm
50cm
Zoom (up)
approx. 85cm
150cm 50cm
Zoom (down) approx. 75cm
50cm approx. 90cm approx. 130cm
approx. 10cm
Zoom (right) approx. 130cm
approx. 10cm
Zoom (left)
10
Wide and Zoom & PanTilt Hands-free Color Video Intercom Wiring 100m / 1.0mma
JK-DV
JK-1ED
JK-1HD
2
COLOR VIDEO ENTRY SECURITY
4 2
JK-1SD
or 4
2 IER-2 PS18
DOOR1
SUB
A1 A2
B1 B2
A1 A2
SUB IN
B1 B2
DOOR RELEASE
L L
EL-12S
PT
IER-2
CALL EXT
1 E
S S
DC18V
DC18V
PS18
ON OFF
Press-to-talk setting switch (only JK-1MD) Option connector
PS18 :PS-1820 PT
:AC Transformer
V+ VSW SW KS KE
Brown Red Orange Yellow Green Blue
External sensor input specification
Video signal output (NTSC, 1Vp-p/75d)
N/O or N/C dry closure contact Input method
Option output (AC/DC24V,1.6A N/O dry closure contact)
Detection confirmation time 100 mS or more Contact resistance
During N/O dry closure: Less than 700d During N/C dry closure: more than 3Kd Less than 10 mA
Terminal short current
External sensor input Setting is required on JK-1MED.
Cable
External sensor input (start signal only detection method)
Voltage between terminals
Less than 20V DC (when open between terminals)
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
Long distance adaptor for JK series
200m / 1.2mma
Features
l When JK series color video door station is more than 100m to max. 300m away.
Used for
2 JKW-BA
JK-DV
A1 A2
JK-1MED
100m / 1.2mma
Unit dimensions
2
A1 B1 A2 B2 + –
C
JK-1MED
A1 A2 + –
Specifications Power source
JKW-BA
Current consumption Wiring Wire type
108.5
JKW-BA
Long distance adaptor
122.5
61
Wiring distance
11
18VDC, PS-1820 of system or separate 95mA 2 parallel wires to ea. door & master. AIPHONE approved product wire: AE7120230B or 1.0mma to 1.2mma. Vinyl jacketed, PE (polyethylene) insulation cable. JK door~JKW-BA 100m~200m(1.2mma) JKW-BA~JK master/JK-1HD/JK-1SD 100m(1.2mma) JKW-BA~PS 100m(1.2mma)
IP color video Intercom adaptor MASTER
DOOR
1
PC
1 10 JKW-IP
Max.20
Power supply PS-1820
JKW-IP
IP color video intercom adaptor
2
Notice • It may not be possible to use this product with certain network environments or PCs. • To use this product via the Internet, a separate broadband connection and a router with a fixed IP address is required. • To ensure proper function only use with approved routers. Refer our homepage for a list of approved routers which allow proper operations. • Maintaining security at the computer(s) connected to the JKW-IP is the responsibility of the customer. Aiphone assumes no responsibility for any losses incurred as a result of improper PC, firewall or other security. • It is recommended that you use a 100BASE-TX wired LAN as the network.
2 2
JK systems
PS18
2
m P.9
PC
Application
• Use of local area networks (LANs) and wide area networks (Internet) allow PCs to be used as a JK master unit • Combine up to 20 JK master/Door systems • 10 PCs can communicate to 20 JK systems • Allow a PC to function as a JK master • Connected PC(s) control PanTilt, zoom and wide views of entryway • Images or movies from entranceways can be recorded and played back at a PC • Use headset (not included) for communication • E-mail can be automatically sent to 10 e-mail addresses when called from door station • Audio recording with manual video recording • Communicate to and from JK masters • A single port can be used for multi-purpose external input
Wide and Zoom & PanTilt control from PC
A user friendly interface contains controls that match those on a JK-1MED. This allows the PC to be controlled in the exact manner as a master monitor.
Wide and Zoom
Wide and Zoom & PanTilt button
PC monitor
WIDE IMAGE
ZOOM IMAGE
PanTilt on Zoom mode
Unlock the door after verifying visitor identity Video & Audio communication with entrance side by PC
Unlock
COLOR VIDEO ENTRY SECURITY
m P.103
Features
VISITOR Door Station
Room to room communication with master station WIDE IMAGE
PanTilt on Zoom mode
(JK- 1MED or JK-1MD)
Cabling 100m / 1.0mma 2
JK-DV
*1
2 2
VISITOR
100m / CAT5e
PS18
CAT5e
2
LAN
ROUTER
PC
JKW-IP
CAT5e PC
100m / 1.0mma
*2
APPLICATION *1 Max. 20x JKW-IP
LAN
ROUTER
CAT5e
JK-1MED
5m / 1.0mma
INTERNET
APPLICATION
*2
*2 Max. 10x PC
Wiring DOOR SUB
A1 A2
IN
B1 B2
A1 A2
B1 B2
DOOR RELEASE
L L
S S
IER-2
1 E
DC18V
PS18
PS18 :PS-1820 PT
Option device input 1
S4 E
Option device input 4
RY RY
Option device Output
*1
~
CALL EXT
LAN, Router etc.
S1 E
~
EL-12S
PT
CAT5e
LAN
*1
DC18V
:AC Transformer
Unit dimensions
*2 Option device output specifications Output method N/O dry contact Voltage between terminals AC24V 0.5A (resistive load) DC24V 0.5A (resistive load) Minimum overload : DC 100mV, 0.1mA
System requirements Windows XP Home/Professional (SP3), Windows Vista Ultimate/Home/Business/Enterprise (SP1)/32-bit version/64-bit version Windows 7 Home Premium/Professional/Enterprise/Ultimate/32-bit version/64-bit version Windows 8/Pro/Enterprise(32/64bit) PC system requirements Processor: 2 GHz or faster System memory (RAM): 1 GB RAM or more Hard disk: 10 MB or more (additional space is needed for recording) Sound card: 8-bit full duplex, Direct Sound compatible Display: 1024 x 768 or greater Run-time: Microsoft ®.NET Framework 2.0 or later Network: 10BASE-T/100BASE-TX Ethernet TCP/IPv4, UDP/IPv4, SIP, Others Protocol 320 k to 8 Mbps (per IP Video Intercom Adaptor) Network bandwidth English, French, Spanish, German, Dutch, Italian, Japanese Language Internet Explorer 6.0 or later (with Internet Options SSL 3.0 enabled) Internet Explorer OS
150
JKW-IP
200
Specifications Power source Power supply Consumption
*2
*1 Option device input specifications N/O or N/C dry closure contact Input method (Start signal only detection method) 100 mS or more Detection confirmation time During N/O dry closure: 700d or less Contact resistance During N/C dry closure: 3Kd or more 10 mA or less Terminal short current 20V or less (when open between terminals) Voltage between terminals
18V DC PS-1820 Max. 200mA
35.5
12
Hands-free Color Video Intercom, Picture Memory DOOR
Features
ROOM
• Two doors & three monitors (3-1/2 inch) • Total hands-free communication, auto-voice actuation • Built-in picture memory; Record visitor both automatically & manually • Voice memo; Internal short voice messages can be recorded and played back
3 JF-2MED
2
Door station
Master station
COLOR VIDEO ENTRY SECURITY
4
2 2
2
IER-2
Call extension m P.98
PT
JF-DV
PS18
Vandal-resistant video door station, surface mount
JF-2MED
Master station w/color monitor and picture memory
2
Access Contorol m P.95 AC-10S or
JF-DVF
Vandal-resistant video door station flush mount
Access control keypad, surface mount
or
AC-10F
JF-D
JF-DA
Access control keypad, flush mount
Audio only door station
Standard video door station
JF-DV + AC-10S
Power supply PS-1820 m P.99
Communication network
Wiring
JF-DV
100m / 1.0mma JF-DV
JF-2HD
100m / 1.0mma JF-2MED
2 2
JF-2SD
JF-2MED
or 2 A1 A2
NP A1 A2
A1 A2
SUB
B1 B2
CALL EXT
S S
EL-12S
M
(BR) (RD)
JF-2SD
4 JF-2SD
JF-2SD or 2
PS18
DOOR2
NP
JF-2HD
2 IER-2
DOOR1
A1 A2
4
2
JF-DVF
M
JF-2HD
RELEASE
NP
IER-2 1 E
ON OFF
ON OFF
SUB IN
SUB IN
B1 B2
SUB OUT
B1 B2
B1 B2
SUB OUT
B1 B2
L L
PT
PS18
DC18V
DC18V
JF-2HD JF-DVF
Selective control of door release at communicating Door station. All-Call the inside stations by voice, then talk individually.
RY-3DL Connection EL-12S
Picture memory 3/16
2006 02 DE C 18 45
8 shots/picture
JF-2MED
RY-3DL
EL-12S
PT
L1 C1 L1 L2 C2 L2
b1 b2 b3 L D1 E D2
OG YE GR BR RD
b1 b2 E L L
DC18V
PRE SS THE TALK BUTTO N TO E ND
BR: Brown RD: Red OG: Orange YE: Yellow GR: Green PS18 : PS-1820: PT AC Transformer
13
PS18
• Message for entrance; Outgoing messages can be recorded and sent out at the door station manually • Streamlined & Thin design, only 32 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions • Visual monitoring with audio for 1 minute • External sensor connectable for notifying and pictograph on monitor • Instant voice call-in with image
• • • • • • • •
Different chimes to indicate which door is calling Press-to-talk operation available All-Call for internal communication Transfer of door station call to other inside stations Selective door release control (with RY-3DL) Optional audio sub master station (JF-2SD) Audio door station in lieu of 2nd video door station Option - Option button, Video signal (NTSC) output, External talk switch, press-to-talk restriction
Lineup
Sub station
JF-2HD
JF-2HD
4
RY-3DL
JBW-BA
KAW-D
EL-12S
Door release adaptor m P.6
or
2
or
Long distance adaptor *Max. 300m away from Master to Door
2
JF-2SD
JF-2SD
Audio sub master station
Audio sub master station
30k angled box m P.97
JBW-D
Electric door strike m P.98
COLOR VIDEO ENTRY SECURITY
Sub master station w/color monitor
Sub master station w/color monitor
15k angled box
Boxed sets JFS-2AED: JF-2MED, JF-DA, PS-2420 JFS-2AEDV: JF-2MED, JF-DV, PS-2420 JFS-2AEDF: JF-2MED, JF-DVF, PS-2420
AE7090210B AE7090210G
AIPHONE approved product wire m P.100
Unit dimensions JF-2SD
173 90
32 5.5
209
(1)
(2) (3)
65cm 70cm
25
98
JF-DA
25
65cm
50cm 95cm
JF-D
131
JF-DVF
JF-DA, JF-DV, JF-DVF
130
135
Image view area
27
JF-DV
160
179
JF-2MED, JF-2HD
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only) 99 45
29 25
Cable
33
Power source Power supply Consumption Calling Communication
61 42
74
AC-10F
100
125
98
Specifications (JF-2MED)
140
122.5
55 68.5
AC-10S
28.5
RY-3DL
JBW-BA
132
88
40
108.5
120
83.5
135 IER-2
98
117
5
45
Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
Video monitor Scanning line Night viewing Door release Wiring Wire type Wiring distance
18V DC PS-1820 Max. 400mA (JF-2MED). Max. 220mA (JF-2HD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3-1/2 inch direct-view TFT color LCD. 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. AIPHONE approved product wire: AE7090210B, AE7090210G Master to door: 50m (0.65mma) 100m (1.0mma) Master to farthest sub: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma)
14
Hands-free Color Video Intercom MASTER
DOOR
120 AX
8 Door station
Central exchange unit Cat5e
COLOR VIDEO ENTRY SECURITY
2 Cat5e
PT
2 PS24
AX-084C
PS24
Central exchange unit, 4 masters and 8 doors
AX-248C (Photo)
AX-DV
Central exchange unit, 8 masters and 24 doors
Color video door station surface mount
AX-DM
AX-DV-P
Audio door station Mullion type
Color video door station w/space for embed proximity reader
AX-320C
Add-on exchange unit, 32 doors
PT
AX-DVF
Color video door station flush mount
AX-DVF-P
Color video door station w/space for embed proximity reader
Features
• All wired on CAT5e, homerun cabling • Total hands-free, auto-voice actuation, communication or Press-to-talk operataion • Two talk channels and two video channels • Communication privacy • Masters available with 3.5-inch color TFT LCD • Selective door release • Master-to-master selective calling and All Call • Standard or Priority call levels from door stations • Scan monitoring:Hands-free audio/visual monitoring • Video output from CEU and AX-8MV • Integrate with CCTV, Access control etc. • PC interface for programming and event logging • Rack or wall mountable CEU • Compatible with IE Series door stations • Optional features: headset, footswitch, and PC remote control
Power supply PS-2420
IE-JA
Audio door station
m P.100
Wiring 300m Door #1 AX-DV
300m
Cat5e
Cat5e
RJ-45
RJ-45 Master #8 AX-8MV
AX-248C
Door #24 AX-DVF
Cat5e
Cat5e
RJ-45
2 2
Door #1 AX-DV
Master #1 AX-8MV
RJ-45
N N
Master #1 AX-8MV
RJ-45
Cat5e AX-248C
M
RJ-45
H
Communication network AX-DV AX-8MV
AX-8MV AX-DVF
+ -+-
Cat5e Door #24 AX-DVF RJ-45
Video signal
M AX-DM
Monitor Calling & communication (w/video from door) Door release
15
N N
Cat5e
N : PS-2420 H : AC transformer
Cat5e
H
RJ-45
Master #8 AX-8MV
Lineup
Master station
EL-12S
AX-8MV
Electric door strike m P.98
AX-16SW
8-call color monitor master station
16-call add-on selector
AX-8MV-W (white)
Cat5e
AC-10S
Access control keypad, surface mount m P.95
AX-8MV, AX-16SW
AX-8M
COLOR VIDEO ENTRY SECURITY
Cat5e
AC-10F
8-call audio master station
Access control keypad, flush mount m P.95
Unit dimensions AX-8MV(-W)
Image view area
AX-8M
• AX-DV, AX-DVF, AX-DV-P, AX-DVF-P ★
175
175
185cm 65cm
★ ★
120cm
194
63
150cm
63
194
★
95cm
50cm ★
AX-16SW
AX-320C
AX-084C, AX-248C
88 85
Calling
63 AX-DV-P
AX-DVF
245
195
AX-DV
100
Power source Power supply Current consumption
25 100
2 45
130 98
1-gang 28
IE-JA 146
2 45
22.5
115
43
116
Video monitor Scaning lines Night viewing Door release contact Outside video output
IF-DA
160
295
146
25
AX-DM
AX-DVF-P
Communication
246
86
approximate
Specifications (AX)
420 426
88 85
175
420 426
50cm
2-gang
Wiring Wiring distance
24V DC, 2A (Two Power supplies per video system) PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5-inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300m (CAT5e) CEU to master: 300m (CAT5e)
10
16
Hands-Free Color Video Multi-tenant Recording, Zoom & PanTilt features GT The GT Series provides building complexes with high performance security & usability. A variety of models adapt to almost any type of building.
Wide and Zoom & PanTilt Panorama Wide Angle View To provide effective security, the GT series features a wide angle camera that enables you to see an innovative panoramic view! People standing on sides and people of all heights can be easily identified.
MULTI-TENANT BUILDING ENTRY SECURITY
Zoom To see details, switch to Zoom mode. Switching between Wide and
With conventional series
Zoom mode can be easily done at the press of a button.
Innovative Wide View of Approx.
170k
PanTilt PAN/TILT is available to change the camera angle in Zoom mode.
Recording Automatic Recording
Manual Recording
Works any time, even during your absence. Records 6 images per
Record picture as required. The recording
picture sequence. Up to 40 picture sequences can be recorded.
starts when you press the REC button while monitoring or talking to a visitor.
Playing The play LED flashes when there are autorecorded pictures.Press the PLAY button to play.
Security Only the master station with the recording function can be
Emergency button
Door sensor.1
connected with 3 security lines. It can also be connected with an emergency button. When sensing an input from the
GT-2C
button, the alarm will be triggered after the set time. Security guard station
GT-MK
17
* The design and specifications are subject to change without notice for improvement.
Door sensor.2
Building System with
High Degree of Usability for Visitors and Other Features Audio & Visual Guidance The Entrance Station features both audio and visual guidance, so any visitor knows the present situation. The audio guide is available in 6 languages (English, French, German, Spanish, Dutch, and Italian).
Please speak now.
Door open.
Supports Hearing Aid with T-mode
MULTI-TENANT BUILDING ENTRY SECURITY
Call in progress.
A T-coil mode is now available with the GT Series. If your hearing aid GT-DA-L
features T-mode, the
Visual guide
GT-DM
sound from the GT room station is much
There are projections on the
&
clearer than other
buttons to help
intercoms.
visually impaired visitors.
Doorbell connections You can connect stations to
Up to 4 Internal Stations can be installed per tenant. Doorbell
your existing doorbell. GT-2C
JK-DV
GT-2H
GT-2C
GT-2H
GT-2H
Capacity Standard
Expanded
48 500 Tenant station
Tenant station Capacity Standard
Expanded
Hands-free color monitor tenant station
GT-2C-L
GT-DM
5 16 Entrance station
Security guard station
Entrance station Capacity Standard
Expanded
2
4
Security guard station
Security guard station GT-MK
18
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt System Configuration Standard system Divided cabling with GT-4Z Trunk line No.1
5 Entrance stations 2 Security guard stations 48 Tenant stations
1Px2 1Px2
1Px2 1Px2
MULTI-TENANT BUILDING ENTRY SECURITY
PS24
Doorbell
GT-1C
GT-1C
1Px2
GT-2C
1Px2 1Px2
Doorbell
Doorbell
PS24
GT-1C
1Px2
GT-2C
1Px2
GT-2C JK-DV or
1Px2
GT-4Z
Doorbell
PS24
GT-2C
JK-DV or
1Px2
1Px2
1Px2
Doorbell
1Px2
Doorbell
GT-2C
GT-1C
PS24
JK-DV or
GT-2C PS24
GT-2H
GT-2H
PS24
GT-2H Tenant
300m / 0.8mma
1Px2
1Px2
GT-2C
No.2~5
Doorbell
150m / 0.8mma
1Px2 GT-BC 1P
PS24 CCTV camera
Coaxial cable
GT-VBC PS24
1P
1P
PS24 1P
1P
Power supply
GT-DM Entrance Station : Max. 5
Wiring distance: Entrance station - Bus & Video control unit 300m Video control unit - Farthest Video Tenant station 150m (Expandable with additional Video control unit) Bus control unit - Farthest Audio Tenant station 300m Accumulated total Audio wiring distance 2,500m
19
PS24
PS24
1Px2
Doorbell
1Px2
Doorbell
GT-1C
1Px2
PS24
JK-DV or
1Px2 GT-2C
GT-2C
PS24
1Px2
GT-4Z
JK-DV or
Doorbell
JK-DV or
1Px2 Doorbell
Doorbell
1Px2
1Px2
GT-4Z
JK-DV or GT-2C
Monitor to monitor cabling Trunk line No.6
On the same trunk line, do not have two wiring methods mixed, Divided cabling with GT-4Z & Monitor to monitor cabling
GT-MK GT-MK Security Guard Station : Max. 2
Expanded system 16 Entrance stations, 2 common trunk lines (8 each per common line) 4 Security guard stations, 2 common trunk lines (2 each per common line) 500 Tenant stations, 4 sub trunk lines (125 each per sub trunk line) Trunk line
No.1
No.6
No.1
Tenant station Max.125 /SUB line
No.6
Tenant station Max. 125 /SUB line
PS24
PS24 1Px2
PS24
PS24
1Px2
PS24 No.2~5
1Px2
GT-BC
1Px2
PS24
PS24
1Px2
1Px2
GT-VBC PS24
No.2~5
GT-BC
1Px2
GT-VBC PS24
SUB 1B & 2A
300m / 0.8mma
1Px2
1Px2
SUB 1A
SUB 2B
COMMON 1 1Px2
COMMON 1 1Px2
1P
1P PS24
PS24 1P
CCTV camera
GT-BCX PS24
1Px2
1P
GT-MK GT-MK Security Guard Station Max. 2/COMMON line GT-BC PS24
1Px2
PS24
1P
GT-VBX
Power Coaxial supply cable
Entrance Station Max. 8/COMMON line COMMON 2
150m / 0.8mma
1P
MULTI-TENANT BUILDING ENTRY SECURITY
PS24
1Px2
GT-BC PS24
COMMON 2 1P PS24
CCTV camera
Power Coaxial supply cable
Entrance Station Max. 8/COMMON line
1P
1P 1P
GT-MK GT-MK Security Guard Station Max. 2/COMMON line
Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m Expanded Video control unit - Video Bus control unit 150m Expanded Bus control unit - Bus control unit 300m Accumulated total Audio wiring distance 2,500m/SUB line
20
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Entrance station All-in-one type
Module type
Digital name scrolling
Direct-select call button
Color camera
Microphone
Color camera
White light LED
White light LED Zinc die-cast panel Speaker
In-use LED
Speaker In-use LED
Guidance display
Display
Microphone
MULTI-TENANT BUILDING ENTRY SECURITY
Call button Access control/ room number dialing keypad
Directory scroll/ Cancel/ Call buttons Directory card & cover Motion sensor
Audio Module
GT-DP
Audio panel for GT-DA
GT-DP-L
Audio panel for GT-DA-L
Camera Module
GT-VP
Camera panel
GT-DA
Audio module
GT-DA-L
Audio module W / guide display
Access control keypad module
GT-VA
Camera module
GT-AC
Access control keypad module
GT-HID
Card reader panel
Option GT-DM
Entrance station with camera with name scroll
GF-AP
Address panel
Address module
GF-BP
Blank panel
Specifications (GT-DM)
Specifications (GT-DA,GT-VA)
Specifications (GT-SW,GT-10K,GT-AD)
Power source
Wiring Type of cable
Lighting Material
24V DC, supplied by PS-2420
Video monitor 3.5-inch color LCD Camera unit Complementary metal oxide semiconductor (CMOS) Communication AUTOMATIC (Hands-free) Mounting Flush-mounting Material Stainless
Mounting Material
21
GT-AD
Two single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B, 3B and GT-4B, and GF-2F, 3F and GT-4F Fire-retardant plastic
Yellow LED Fire-retardant plastic
Specifications (GT-NS) Power source Material
24V DC, supplied by PS-2420 Fire-retardant plastic
l 170° range wide view camera l Audio & visual guidance assists the visitor to know the present status and go on to the next step at ease. l Searches of names and number using the keypad l Customer programmable welcome messages can also be shown l 6 languages (English, French, German, Spanish, Dutch & Italian) are available for audio guidance and messages on Guidance display l White light LED illuminates the visitor automatically in low-light conditions
Digital name scrolling White light LED
Guidance display
VFD Display Directory scroll/ Cancel/ Call buttons
Access control/ room number dialing keypad
GT-4F
GT-4B
GF-3F
GF-3B
4-module front frame 3-module front frame
GF-2F
2-module front frame
4-module back box 3-module back box
GF-2B
2-module back box
Digital name scrolling module
GT-NSP-L
Display module panel
GT-NS
Digital name scroll display module
Front frame & back box
GF-10KP
10-key module panel
MULTI-TENANT BUILDING ENTRY SECURITY
Keypad illumination
GT-10K
10-key module
SBX-GTDM
Call switch Module
Surface Mount Box for GT-DM
GT-nH
Rain hood
GT-nHB
Hooded surface-mount box
GF-nBA
Surface-mount box
GF-1P
1-call panel
GF-2P
2-call panel
GF-3P
3-call panel
GF-4P
4-call panel
GT-SW
Call switch module
Easy system setting on a PC l Settings can be made from a PC by using the Setting Software. l Connecting the unit and a PC via USB l Supported OS: Windows XP (SP3 or higher), Windows VISTA (SP2 or higher), Windows 7, Windows 8
22
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Unit dimensions GT-DM
Audio/Video + Name scroll
Audio/Video + Name scroll
410
425
320
225
4-call
270 16
135
60
GT-VP
93 8
110
8
108
110 GT-SW
93
95.2
90.5
GF-4P
GT-VA
108
18.5 38
15.8
110
135 106
4.5 38
44
GT-104HB 23
155
68
GF-10KP 96.1
90.5
GT-10K
110
16
GT-104H 155
14.4
10.5
443
9 110 GT-NSP-L
38
95.2
GT-NS 106
4.5 38
443
106
90.5
MULTI-TENANT BUILDING ENTRY SECURITY
95
GT-DA/GT-DA-L 11 38
95
GT-DP/GT-DP-L
400
8
GT-4B
GT-4F
44
44
44
425
150
16
135
16
110
15.5
Security camera You can select one of the cameras placed at the entrance, and monitor the entrance. This allows you to confirm visitors from various angles, thus enabling blocking intrusion by suspicious individuals.
CCTV camera
Video Monitoring Wiring
GT-DM CN2
CCTV camera
2C
(Brown) (Red)
Entrance station GT-2C-L
GT-VA CN4
CCTV camera
23
2C
(Brown) (Red)
Entrance station components Number of calling button
(2) (3) (4) (5) (6)
(7)
8.
12.
16.
20.
24.
1 1 1 1 1 1 1 1 -
1 1 1 1 2 2 1 1 -
1 1 1 1 3 3 2 2 -
1 1 1 1 4 4 2 2 -
1 1 1 1 5 5 2 2 -
1 1 1 1 6 6 3 3 1
-
-
1
-
1
-
-
-
-
-
-
-
-
1 1 1 1
25.~48.
GT-NS, GT-10K
1 1 1 1 1 1 -
For more than 7 GT-SW, install additional power supply & special device required. Contact local AIPHONE distributor
(1) Camera (2) Audio (3) Call switch (4) 3-module Front frame (5) 4-module Front frame (6) Option (7) Digital name scroll
GF-3F
. GT-nHB
. GT-nH
Mounting GF-3B
GT-DA
GT-DP
W
23
H H
H
(3)
GT-SW
H
(5)
(2)
(1)
61
68
(4)
GF-4P
W
. GF-nBA
W
W 45
GT-102H/HB
243 155
GT-202H/HB
243 290
GT-103H/HB
338 155
GT-203H/HB
338 290
GF-202BA 229 274
GT-303HB
338 425
GF-103BA 324 139
GT-104H/HB
443 155
GF-203BA 324 274
H
W
GF-102BA 229 139
(1) Tamper-proof screw & screwdriver(supplied with GT-BC) (2) Module-mounting bracket(supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box 1.
2.
3.
4. GF-2B/3B W GT-4B x1 110 x2 245 x3 380 x4 295 515 mm x5 650 x6 785 x7 920 x8 1055 x9 1190 44mm
(1)
(1)
200 mm
400 mm 25mm
25mm
W
W (2)
44mm
W
(2)
44mm
25mm
(2)
Interconnecting Modules with Plug-in Conectors
Image view area (WIDE)
GT-VA
(ZOOM & PanTilt) approx. 200cm
Zoom (down)
approx. 85cm
155cm
CN1
approx. 225cm
CN3
Zoom (up)
approx. 70cm
approx. 95cm 50cm
GT-NS CN3
approx. 85cm
approx. 105cm
155cm
1. One 4-module back boxes 2. Two 2-module back boxes 3. Three 3-module back boxes 4. Back box total width (mm) (1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
MULTI-TENANT BUILDING ENTRY SECURITY
GT-VA GT-VP GT-DA(-L) GT-DP(-L) GT-SW GF-4P GF-3F GF-3B GT-4F GT-4B GF-BP GT-AD GF-AP GT-NS GT-NSP-L GT-10K GF-10KP
(1)
4.
50cm
approx. 75cm
CN1 CN2 GT-DA-L
GT-10K CN3 CN1
50cm approx. 170˚
approx. 90cm approx. 130cm approx. 10cm Zoom (right) approx. 130cm
CN1 CN2
CN2 CN1
CN1 CN2
CN2 CN1
approx. 10cm
Zoom (left)
24
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Hands-free color monitor tenant station w/ picture memory
Picture memory
or
GT-2C-L
Features (GT-2C-L, GT-2C) Exclusive functions available for GT-2C-L/GT-2C (In addition to GT-1C(-L)) • Video recording from an entrance station or video door station • Sensors (commercially available) can be connected for security • Up to 4 monitor stations can be linked per Tenant • Individual Video door station/audio door station can be connected. • Internal call and communication
Hearing aid
GT-2C
Option Max. 3 sub master monitor stations (GT-2H-L or GT-2H) can be connected (total of 4 per room)
MULTI-TENANT BUILDING ENTRY SECURITY
Hearing aid
Other basic functions • Refer to the features for the GT-1C-L/GT-1C. Items listed in the corresponding section can be used as common basic functions.
GT-2H(-L)
+
+
or
w/o picture memory
Features (GT-1C-L, GT-1C)
Hearing aid
or
GT-1C
GT-1C-L
Option
• Zoom/wide and pan & tilt video monitoring function • 3.5-inch LCD for operation and video monitoring • Hands-free communication, auto-voice actuation • Press-to-talk communication is available • Video image adjusting function • Monitoring an entrance station or video door station • Lighting control for a call from entrance station • Releasing door lock • Security guard call • Auto-entry (Doctor call) • Optional handset for private communication
Max. 3 additional stations (*) can be connected (total of 4 per room)
Common items
Optional Handset
+
Specifications (GT-2C-L, GT-2C, GT-1C-L, GT-1C, GT-2H-L, GT-2H) Power source
Video monitor Wiring Mounting Material
Unit dimensions GT-2C-L, GT-2C, GT-1C-L, GT-1C, GT-2H-L, GT-2H
GT-HS
140
177
GT-HS
GT-2C-L, GT-2C: 24V DC, supplied by PS-2420 GT-2H-L, GT-2H: 24V DC, supplied by GT-2C-L, GT-2C GT-1C-L, GT-1C: 24V DC, supplied from Bus control unit, GT-BC & GT-VBC 3.5-inch TFT color LCD Two Single –pair cables common Wall-mounting only Fire-retardant plastic
140
+
(*) Max. 1 additional monitor station can be installed (GT-1C, GT-1C-L or GT-1M-L). Max. 3 additional audio stations can be installed (GT-1A or GT-1D). If 1 additional monitor is installed, max. 2 additional audio stations can be installed.
190
30 45
25
46
Features (GT-1M-L)
• 3.5-inch LCD for operation and video monitoring • Lighting control for a call from entrance station • Monitoring an entrance station • Releasing door lock • Security guard call • Auto-entry (Doctor call)
Hearing aid
Unit dimensions GT-1M-L
210
Color monitor tenant station
Specifications (GT-1M-L)
GT-1M-L
Monitor tenant station
24V DC, supplied from Bus control unit, GT-BC & GT-VBC
Video monitor
3.5-inch color LCD
Wiring
Two Single-pair cables common
Mounting
Wall-mounting only
Material
Fire-retardant plastic
215
Features (GT-1A, GT-1D)
Unit dimensions
• Lighting control for a call from entrance station • Monitoring an entrance station • Releasing door lock • Auto-entry (Doctor call)
175
GT-1A
125
GT-1A
Audio tenant station
200 89
GT-1D
Audio tenant station
63
Specifications (GT-1A)
Specifications (GT-1D)
Power source
24V DC, supplied from Bus control units GT-BC
Power source
24V DC, supplied from Bus control unit GT-BC
Wiring
Single-pair cable common
Mounting
Wall-mounting only
Wiring Mounting
Single-pair cable common Wall-mounting only
Material
Fire-retardant plastic
Material
Fire-retardant plastic
Trunk line
Functions Buzzer
Tenant master station
Panic alarm
Cal GT-2C
1Px2
O
1Px2
PANIC CALL switch
&C
om
ory em n larm g m atio ic a callin unic Pan ce mm Co sen Ab ng & li Cal
Cal ling &C Do or r om ele mu Mo a nic se nito atio rin n g (a udi o/ vid eo)
ling
mu
nic
atio
Calling & Communication Door release Monitoring (audio) Reception mode function
Monitor to monitor cabling
Divided cabling with GT-4Z
External signaling
Video door station or
Entrance station
32
GT-1D
Hearing aid
Doorbell
69
MULTI-TENANT BUILDING ENTRY SECURITY
Audio tenant station
Power source
n
PS24
1Px2
1Px2
GT-2C
GT-2C
PS24
GT-2C PS24 1Px2
GT-2C
PS24
GT-2C
GT-4Z
GT-2H 1Px2 PS24
GT-2C
Only available to connect on a trunk line with GT-4Z used
1Px2
1Px2 PS24
1Px2 On the same trunk line do not have two wiring methods mixed, Divided cabling with GT-4Z & Monitor to monitor cabling
Security guard station
26
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Video door station
Features l 170krange wide view camera l Directory card with backlight (JK-DV, JK-DVF) l White light LED illuminates the visitor automatically in low-light conditions
Specifications (JK-DA, JK-DV, JK-DVF)
JK-DA
Wide and Zoom & PanTilt video door station, surface mount
Power source Type of communication Camera Minimum illumination Camera angle Mounting Material
Supplied from Tenant station Open voice hands-free communication 1/4-inch color CMOS 5 Lux Wide: 170k (approx.)(Horizontal) JK-DA, JK-DV: Surface wall mount (Directly to wall or electrical box) JK-DVF: Flush mount JK-DA: Fire-retardant PC + ABS plastic JK-DV: Zinc diecasting JK-DVF: Front panel Stainless steel
JK-DV
Wide and Zoom & PanTilt Vandal resistant video door station, surface mount
29.5
173
JK-DV
129
JK-DA
97
JK-DVF
35.5 98
25 135
Image view area Refer to the descriptions for the image view area. m P.10
JK-DVF
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount
Door station Specifications Power source Type of Communication Mounting Material
Unit dimensions
GT-D
GT-D
130
Audio only door station
98
27
8
209
MULTI-TENANT BUILDING ENTRY SECURITY
Unit dimensions
28.5
Supplied from Tenant station Open voice hands-free communication Surface wall mount Fire-retardant PC + ABS plastic
45
Security guard station
GT-MK
Security guard station
Features
Unit dimensions
l Call to tenant station GT-MK l Digital display shows name of tenant & 210 number l Entrance station call-ins made to the indoor unit can be automatically forwarded to the security guard station. l Absence call-in memory stored with Callback 215 69 l Option (GT-MK) Specifications Doorbell at door with different call tone User-optional device can be controlled with Power source 24V DC, supplied by PS-2420 SERVICE button, such as Max. 16 letters for names; English VFD display -light on and off at entry way to elevator (Up to 32 characters can be registered.), l Receive a Panic call from tenant station French, German, Spanish, Dutch & Italian
Desk-top stand
2 single-pair cables 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia.
Mounting
Wall-mounting or Desk-top mounting on GFW-S Fire-retardant plastic
Material
Control units System layout example BUS (Audio/Video) MAX.6 Divided cabling with GT-4Z
2
3
4
5
6
150m
1
1P(Audio) 1P(Video)
Monitor to monitor cabling Expand pos.
GT-2C
GT-4Z
1Px2 1Px2
GT-2C PS24
GT-2C
GT-2C
PS24
PS24
GT-2C PS24
GT-2C
GT-BC
GT-BC
Bus control unit
EXP
On a single trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GT-4Z
STD
max. 2 GT-VBC PS24
PS24
GT-VBC
150m
PS24
GT-BC GT-VBC PS24 PS24
PS24
300m
1Px3
PS24
PS24
EXP
STD
MULTI-TENANT BUILDING ENTRY SECURITY
GFW-S
Wiring Type of cable
Standard pos.
Wire type GT-VBC
Video Bus control unit, expander video control
AIPHONE approved product wire: AE7090220B, AE7090220G AE7090210B, AE7090210G or 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia.
Wiring distance GT-BC, GT-VBC to Farthest Entrance station GT-BC, GT-VBC to Farthest Video tenant station GT-BC, GT-VBC to Farthest Audio tenant station GT-BC, GT-VBC to each Power supply Accumulated Audio lines (R1, R2) Total wiring distance
Specifications (GT-BC, GT-VBC)
Unit dimensions
Video 4-zone divider
Power source
GT-BC, GT-VBC, GT-4Z
Consumption Wiring Housing
108.5
GT-4Z
122.5
Distance (Diameter of wires) 300m(0.8mm) 150m(0.8mm) Expandable 150m with additional GT-VBC & Power supply 300m(0.8mm) 5m(0.8mm) 2,500m(0.8mm)
61
24V DC, supplied by PS-2420 900mA. Single-pair cable common Fire-retardant plastic
Specifications (GT-4Z) Wiring Material
Two Single-pair cables common Fire-retardant plastic
28
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Expanded control units Features
l Expandable to max. 500 Tenant stations, 16 Entrance stations, and 4 Security guard stations
System layout example
GT-BC
GT-BCX
Expanded Bus control unit
PS24
PS24
GT-2C
GT-2C
GT-VBC
GT-BC
SUB1B SUB2A
PS24
1Px2
SUB1A
1Px2
1Px2 COMMON 1
GT-VBC
PS24
SUB2B
COMMON 1
PS24
PS24
GT-BCX PS24
GT-VBX GT-MK COMMON 2
GT-MK
GT-MK
GT-MK
PS24
PS24
GT-BC PS24
GT-BC PS24
l COMMON trunk line: Requires one each of GT-BC & Power supply l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations l SUB COMMON trunk line: Max. 125 Tenant stations
GT-VBX
Expanded video control unit
Specifications (GT-BCX, GT-VBX)
Unit dimensions
Power source GT-BCX: 24V DC, supplied by PS-2420.
GT-BCX, GT-VBX
GT-VBX: Supplied from GT-BCX
108
MULTI-TENANT BUILDING ENTRY SECURITY
1Px2 COMMON 2
61
210
Wiring
Single-pair cable common
Material
Fire-retardant plastic
Power supply Unit dimensions
Specifications (PS-2420)
PS-2420
Input voltage & Capacity
52
Output voltage
24V DC, 2A
167
90
100-240V AC, 50/60Hz 60W/100-125VA
PS-2420
Option
GT-RY
External signaling relay entrance light, external buzzer
29
W-DIN11
DIN mounting rail for GT-BC, GT-VBC, GT-4Z
AC-10S
Access control keypad, surface mount m P.99
AC-10F
Access control keypad, flush mount m P.99
AE7090220B AE7090220G AE7090210B AE7090210G
AIPHONE approved product wire m P.104
GT Lift control adaptor Features l Lift is controllable from tenant station while communicating with entrance station. When door release button is pressed, electric door strike is activated and simultaneously output signal is transmitted to the lift controller or the access controller. The access is authorised only to the floor of communicated tenant station. l Selectable dry contact: Normally Open or Normally Closed l System set up data is programmable on your PC
GTW-LC
Lift control adaptor
* GT-BCX is required to use GTW-LC.
Cabling
1P(Audio)*1 1P(Video)*2 1P
eas
e
mm
rel
Co
)
Ca
on
cti
Do
or
ea
(on
g&
GT-2C
ol
llin
PS24
ntr
un
Co
ica
tio
n
GT-2C
GT-VBC
Access authorised only to the floor of communicated tenant station
GT-BC
PS24
MULTI-TENANT BUILDING ENTRY SECURITY
Functions
Lift Entrance station Connection with GTW-LC, Lift control unit GT-VBX
Unit dimensions
GT-BC
GT-BCX PS24
PS24
Distribution point
GTW-LC
PS24
GT-BC
108
GT-BC
PS24
210
61
GTW-LC
Specifications Power source Relay
Wiring Material
Supplied by GT-BC Output 20 Contact rating 24V AC/DC, 0.5A N/O or N/C dry contact Operating time From 1 to 600 seconds Single-pair cable Fire-retardant plastic
PS24
Lift controller
Lift
GT Expanded system *1. AIPHONE approved product wire: AE7090220B, AE7090210B *2. AIPHONE approved product wire: AE7090220G, AE7090210G PS24
: PS-2420
30
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Cabling 1P(Audio)*1 1P(Video)*2 1P
Standard system Capacity 5 Entrance stations 2 Security guard stations 48 Tenant stations
Divided cabling with GT-4Z 1Px2
Trunk line No.1
1Px2
1Px2
GT-4Z
Monitor to monitor cabling
1Px2
JK-DV
Trunk line No.2
JK-DV 1Px2
GT-2C
GT-2C
or
or
MULTI-TENANT BUILDING ENTRY SECURITY
PS24
Doorbell
GT-2C
PS24
1Px2 1Px2
Doorbell
1Px2
GT-4Z
PS24
1Px2
1Px2
JK-DV JK-DV 1Px2
1Px2
1Px2
or GT-2C
Doorbell
PS24
GT-2C
PS24
GT-2H
GT-2H
GT-2H
GT-2C
Max. 4 internal stations can be linked per Tenant
PS24 1Px2
1Px2 On the same trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GT-4Z 1Px2
Trunk line No. 3 to 6 1Px2
Distribution
R1
point
PS24
R2 GT-BC
GT-VBC
1Px2
Light control Timer
Entrance No. 2 to 5
GT-RY 1P
1Px2 1Px2
AC
1P 1P
1P 1P
CCTV camera Light Doorbell Coaxial cable
Door release Entrance station
PS24
Entrance station
Door release
Power supply
GT-MK Security guard station
Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation
31
GT-MK
PS24
Security guard station
Wiring Divided cabling with GT-4Z Trunk line No.1 GT-4Z
B1 OUT B2
A B R1 R2 B1 B2
B1 IN B2 R1 OUT R2 IN
1Px2
R1 R2 H1 H2 A1 A2
+ -
OUT
B1 B2
Power supply A GT-2C
IN
B1 B2
AC
R1 OUT R2
JK-DV A1 A2
or Door bell AC
Trunk line No.2 A1 A2
R1 OUT R2
1Px2
JK-DV or
R1 IN R2
B1 B2 R1 R2
B1 OUT B2
H1 H2
B1 IN B2
A1 A2
GT-4Z
1Px2
A B1 B2 OUT 1 R1 R2
R1 IN R2 H1 H2
A
+ -
OUT 2
B1 B2 R1 R2
1Px2
AC
R1 IN R2
Power supply
A1 A2
GT-2C
B1 IN B2 SW2 CN4
SW2 CN4
R1 IN R2
H1 OUT H2
H1 OUT H2
A1 A2
H1 H2
H1 IN H2
H1 IN H2
JK-DV
A1 A2 + + - -
+ -
AC
GT-2H
GT-2H
+ -
+ + - -
Power supply
+ -
+ -
R1 OUT R2
LINE IN R1 R2 B1 B2
Power supply A GT-2C
B1 OUT B2
1Px2
B
A
1Px2
B
AC
Power supply
GT-2C
B1 OUT B2 B1 IN B2 R1 OUT R2
A
GT-2C
Door bell
R1 OUT R2
+ -
+ -
A1 A2 + -
Monitor to monitor cabling
B1 IN B2
R1 IN R2 A1 A2
1Px2
Trunk line No. 3 to 6
+ -
+ A
B
AC
Power supply
GT-2C 1Px2
Distribution point
R1 R2
Power supply
+ -
+ -
GT-BC
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 + -
IN1
IN2
IN3
IN4
IN5
SW2
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
EXP
STD
GT-VBC
AC Video Entrance station No. 3 to 5
1P Doorbell Light control Timer Orange
Light AC
Blue
Orange GT-RY White
MULTI-TENANT BUILDING ENTRY SECURITY
+ -
R1 R2 B1 B2 LINE OUT B1 B2 OUT 3 OUT 4 R1 R2
B1 OUT B2
Terminate the last GT-4Z
Door release
1Px2
PT
Entrance station CN2
A1 A2 R1 R2 ELM ELC ELM BP BP + -
GT-DM
CN2
A1 A2 R1 R2 ELM ELC ELM BP BP + -
GT-DM
CCTV camera
GT-MK
2nd GT-MK
R1 R2
R1 R2
R1 R2 C CE + -
R1 R2 C CE + -
SW1
AC
SW1
+
button
AC
-
Power supply
+ -
Power supply
AC *1. AIPHONE approved product wire: AE7090220B, AE7090210B *2. AIPHONE approved product wire: AE7090220G, AE7090210G
32
Hands-Free Color Video Multi-tenant Building System with Recording, Zoom & PanTilt Compatibility with the existing system The GT system follows the GH trunk line. Both systems can be mixed for call and communication performance, however the use of some functions are restricted. Some functions are enabled on a single station, and some depends on the system.
Main functions that are enabled on a single station GT-2C-L, GT-2C
GT-1C-L, GT-1C l Recording function
l Selectable call-in tones (2 tones)
l 3 add-on master stations l Individual door station l Selectable call-in tones (5 tones) l Security or general purpose call
GT-1M-L
GT-1D l Handset T-mode communication
l Handset T-mode communication
MULTI-TENANT BUILDING ENTRY SECURITY
New entrance station
GT-MK l Audio guidance
l Handset T-mode communication
l Room number search in numerical order
l External output setting
l Night illumination normally-off
l Call-restricting function
l The external door release button
l Room number search in numerical order
Main functions that depend on the system and the old GH and new GT system compatibility list Existing GH and new GT system The existing GH compatibility list entrance
The existing GH security guard stations and stations and the new GT system the new GT system
Zoom/wide and pan & tilt
✓
Video image adjusting function for viewability
✓
Calling a security guard station individually (that has the recording function only)
✓
Absence call-in records from the security guard station (that has the recording function only)
✓
Releasing the door while being called-in
The existing GH tenant stations and the new GT system
The new GT entrance stations and the existing GH system
✓
The new GT security guard stations and the existing GH system
The new GT tenant stations and the existing GH system
✓
✓
Confirmation sound and LED indication at link setting Switching the security camera
✓
✓
✓
*Transferring link setting information from the new system to the old system is not possible.
33
INTEGRATED SECURITY & COMMUNICATION SYSTEM Innovative network-based security management systems. Manage not only your door entry security, but also internal communication through one system via a local network or the internet to dramatically improve security efficiency. Find Out the Solutions for Your Security Needs. Large Corporations Protect staff by giving them the advantage to safely confirm the identity of visitors and vendors before granting access into the building.
Airports
Communications between several departments at separated places can be smoothly realized.
Schools
Shopping Mall Internal communication between tenants can be easily done. It contributes to prompt action in emergency conditions, such as quick call to a disaster control center.
Hospitals
Increase staff efficiency by controlling various entrances from a central location. Easily transfer responsibilities to another location or individual.
Parking Garages
Assist visitors and monitor multiple garage entrances from remote locations during or after hours.
Lineup IP Network Audio - Video Intercom System
IX series
P35l
Security IP Video Intercom System
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Broadcast messages throughout the school or to a particular classroom with the choice of either a hands-free or handset reply.
Integratable Audio / Video Security
IS series
AX series
P47l
P59l
34
IP Network Audio - Video Intercom System IX Greater flexibility, covering more applications. The IX System – getting the job done for a wide range of business applications, while achieving connection and integration with third-party IP systems. Full IP-network compatibility
VPN/LAN
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Security enhanced Integration
Network Camera
Card Reader
35
Access Control
VMS/NVR
Emergency Call
Paging
Full IP-network compatibility, simple installation, and greater flexibility. Enables to communicate between an infinite number of door/master stations with no distance limitations. Helps save money as no server is required to build a system.
No server configuration results in space savings, reduced installation time, and lower cost
Unlimited number of devices IP addresses for up to 500 devices can be registered for each master station – plenty of coverage even in large-scale applications.
X
500
Simply connect the units to Power over Ethernet (PoE) switches. This means no need for a dedicated server, with the additional benefit of eliminating the risk of system downtime due to server malfunction.
PoE design
LAN and VPN connections enable implementation over extensive areas and between remote locations. This system allows for closed circuit communication and central control in large facilities, between corporate and satellite offices, and any type of application with multiple locations.
Electrical power is supplied over the LAN port connection.
INTEGRATED SECURITY & COMMUNICATION SYSTEM
No wiring-distance limitations
Server
Integration with other IP-based security systems Using an existing IP infrastructure, IX System can be integrated with Video Management System, Access Control System, and Network Camera System, etc. Combining security components saves time and resources during set-up and training.
Compatible with third-party systems This system is compatible with the ONVIF Profile S-established interface specifications for network camera equipment. This allows the intercom to be used with third-party systems, enabling interoperability of integrated IP systems. The open API allows for configuring IP systems with greater flexibility.
Examples of Integration
IX-MV
An ONVIF compatible VMS/NVR system Access control system
Use with a Video Management System and Access Control
24
Interconnection with an ONVIF Profile S-compatible network camera system lets you transform door station into surveillance cameras for facial identification of visitors. Integrate with video management systems for 24/7 recording. Integration with third-party access control is also possible. *VMS (video management system): XProtect® by Milestone Systems *Access control:OnGuard® by Lenel
7
Clearly identify visitors with both the intercom and Network camera.
36
IP Network Audio - Video Intercom System
Custom settings for a variety of features. Call Queuing Master stations can receive up to 20 incoming calls simultaneously. Caller information can be displayed on a call queue list, making it possible to respond selectively to high-priority calls.
Page to all stations or individual groups Page to all stations and page to preset specific groups is possible. A third-party paging amplifier can be connected for additional coverage.
Group No.1 Group No.2
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Group No.49 Group No.50
PA amplifier
Speaker
Unicast / Multicast
Customize with prerecorded messages
According to an infrastructure, there is a choice of sending data via Unicast or Multicast. Paging to all stations can be done using Multicast, and for Unicast communication, paging up to 50 stations is possible.
Create and import custom audio files for use as unique voice messages. For visitors at door stations, voice messages let them know that door is open.
Send E-mail
For security guards/receptions at master stations, voice messages help them to identify incoming calls instantly.
When master stations are called, IX System can send an E-mail attached with the visitor’s picture up to 3 E-mail addresses. Error in the system and health check report can be also sent via E-mail.
Door is open
Call from customer entry point
Notification of call and communication status Indicator lamps and sounds or voice messages provide notification of call and communication status for security and peace of mind. Call in Progress
The Call indicator flash in orange. Communication in Progress
The Communication indicator flash in green.
37
A wide array of call transfer features The system offers an array of call transfer features that can be set to meet the application.
1Communication
Manual transfer
2Transfer
A call from a door station can be placed on hold and transfered to another master station manually by the user.
3Communication
Delay transfer
Transfer
If no response occurs within a set interval, call is automatically transfered to a pre-programmed master station.
No response within a set interval
Transfer
Call is automatically transfered to a different master station immediately.
Schedule transfer Call is automatically transfered to a preset master station during scheduled times, such as after normal business hours.
Office hours
After hours Security company
Transfer
Usage-specific individual calls and simultaneous calls to multiple devices Door station can call up to 20 master stations simultaneously. Master station can call up to 50 other master stations in a group simultaneously. Receptionist
Entrance Individual call
Up to 50 master stations can be registered in a group. Maximum 50 groups can be registered.
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Absent transfer
Group call Individual call
Office No.1
Office No.2
Office No.3
38
IP Network Audio - Video Intercom System Examples of Popular Applications Airports All-in-one system for Internal communication, Access Control for restricted area, and Video surveillance. Employees can communicate with each other efficiently and effectively. Access at public entrances can be controlled with facial identification. Integration with access control is also possible.
Security Control Center 2014.01.23 AM09:01 office door open 2014.01.24 AM09:05 office door open 2014.01.24 PM05:09 office door open 2014.01.25 AM09:01 office door open 2014.01.25 AM10:06 office door open 2014.01.25 PM03:21 office door open 2014.01.25 PM07:20 office door open 2014.01.23 AM09:01 office door open Name
John Smith XXXXXXXXXXXXXXX XXXXXXXXXXXXXX XXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXX
Staff Room IX-MV
IX-MV
IX-DF-P
IX-DF-P
VMS Access Control
Entrance
IX-DF Entrance
INTEGRATED SECURITY & COMMUNICATION SYSTEM
IX-DF
IX-DF
Railways All-in-one system for Help points, Communication between distant stations, and Video surveillance. Response can be made to calls and queries from ticket machines, ticket gates, and platforms with video monitoring. Communication between distant stations is also possible.
Station A Station B Control room
IX-MV
IX-MV IX-MV
VMS
IX-DF Station C
Virtual Private Network
IX-MV IX-DA IX-DF
39
IX-DA
IX-MV
Schools All-in-one system for Door Entry management, Call transfer for after hours, and Emergency paging. Management of entry and exit points integrated with access control can be accomplished. The system can also be used to enable teachers and staff members to easily communicate with one another. After hours control for schools within the district can be performed at a central control site.
School A
Security Camera
Security Camera
School B
Security Camera
School C
Virtual Private Network
Central Control Center Administration
Office
Classroom
IX-DF IX-MV
VMS
IX-MV
Parking facilities All-in-one system for Emergency call, Remote control of distant parkings, and Video surveillance. Audio communication and video identification allows for immediate where assistance is needed. Crime prevention can be enhanced further through simultaneous installation of network cameras.
Security Control Center
Security Camera IX-MV
IX-DF Security Camera
VMS
IX-DF Security Camera
Virtual Private Network
IX-DF Security Camera
INTEGRATED SECURITY & COMMUNICATION SYSTEM
IX-MV IX-MV
IX-DF Security Camera IX-DA
Security Camera
Emergency Call
40
IP Network Audio - Video Intercom System System Configuration Virtual Private Network
WAN system LAN system
Router CAT5e/6
PoE Switch
CAT5e/6
100m
CAT5e/6
100m
IX-MV
CAT5e/6
CAT5e/6
CAT5e/6
100m
IX-DA
100m
100m
IX-DF
IX-BA
PoE Switch
Contact input
Relay output
Relay output
Audio output
Contact input
Relay output
INTEGRATED SECURITY & COMMUNICATION SYSTEM
PA amplifier
Electric lock
Speaker
Electric lock
IX-SS
Audio output
PA amplifier
Electric lock
Speaker
100m
IX-DF-P
CAT5e/6 2014.01.23 2014.01.24 2014.01.24 2014.01.25 2014.01.25 2014.01.25 2014.01.25 2014.01.23
AM09:01 office door open AM09:05 office door open PM05:09 office door open AM09:01 office door open AM10:06 office door open PM03:21 office door open PM07:20 office door open AM09:01 office door open
Name
John Smith XXXXXXXXXXXXXXX XXXXXXXXXXXXXX XXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXX XXXXXXXXXXX
An ONVIF Profile S compatible Network camera
An ONVIF Profile S compatible VMS/NVR system
Access Control System
Card reader
Number of station registrations in address book Product number
Product name
Number of station registrations in address book
IX-MV
Master Station
500 stations
IX-DA, IX-DF, IX-DF-PI*1, IX-DF-P*1
Video Door Station Audio Only Door Station
20 stations*2 20 stations*2
IX-BA, IX-SS *1 Card Reader is not included. *2 Only Master Stations can be registered (Max. 20).
41
Contact input
Serverless Configuration Achieves Savings in Space and Installation Work, and Lower Costs Internet
Typical Systems
PoE switch
Typical systems require a “separate server” and the attendant effort of installation work and administration.
Router
Server Control unit Expansion unit
Expansion unit
The IX System is serverless, which eliminates the risk of system downtime due to server malfunction.
PoE switch
Router
ONVIF-compatible ONVIF-compatible network camera network camera
A Guide to Terms ONVIF (Open Network Video Interface Forum) The interface specifications established by ONVIF provide standards that enable exchange of live video and audio as well as control information and the like by surveillance cameras and other network video devices feed, even among products from different manufacturers.
INTEGRATED SECURITY & COMMUNICATION SYSTEM
VPN connection
IX System
VMS (Video Management Software [or "System"]) This refers to video management software using an IP network. Servers and cameras of any make can be installed, enabling configuration of systems matched to user needs.
NVR (Network Video Recorder)
This is a device that records video feed from a network camera over an IP network.
Open API This refers to a publicly disclosed set of commands and functions that can be used in programming. It enables control of intercom functioning by user programs, and also makes it possible for user programs to acquire information from intercoms.
42
IP Network Audio - Video Intercom System Master station
IX-MV
IP Direct Audio and Video Master Station
Features
Specifications (IX-MV)
• Directly connectable to an IP network • 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, push-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Video image adjusting function • Call or communication transferring to another master station • Paging to a group or all stations • Monitoring a single station • Power supply by the PoE
Power source
Power-over-Ethernet (IEEE 802.3af Class 0) Communication Hands-free/Push-to-talk Handset:Full-duplex/Push-to-talk Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin
Wiring
Unit dimensions
2C L
Relay output
L
38 250
Audio door station
59
• Directly connectable to an IP network • Door release output • LED indicator active while calling, talking, and releasing the door • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Power supply by the PoE
PoE-enabled switch
2C S SE
Polarized
Contact Input
Specifications (IX-BA) Power source
Power-over-Ethernet (IEEE 802.3af Class 0)
Communication
Open voice hands-free communication
Mounting Material
Surface-wall mount (directly to wall) Front panel: Fire-retardant resin Main unit: flame resisting PC+ABS resin
Unit dimensions
IX-BA
IX-BA
IX-SS
96.8
23
265
129
IP Direct Audio Door Station
42
150
2 45
Wiring IX-BA IX-SS
2C Contact Input
IX-SS
IP Direct Audio Door Station • Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1
Polarized
Brown Red
Shielded wire Audio Output (to paging amplifier)
Orange Yellow
2C Relay Output (the electric lock) 15m
43
CAT5e/6
Green Blue Purple
S SE P P NO COM NC
100 m LAN/PoE
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Features
100 m
LAN/PoE
189 162
IX-MV
CAT5e/6
PoE-enabled switch
IP Direct Audio and Video Door Station
Unit dimensions
• Directly connectable to an IP network • Door release output • The indicator flash by press the button, talking, door releasing • White light LED to illuminate the visitor automatically at night • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Power supply by the PoE
129
IX-DA
96.8
23 42
IX-DF
IX-DF-P,IX-DF-PI
Specifications (IX-DA)
265
IX-DA
Features
265
Video door station
Power source
IP Direct Audio and Video Door Station
• Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1
IX-DA, IX-DF IX-DF-P, IX-DF-PI
150
2 45
Brown
Polarized
Red
Shielded wire Audio Output (to paging amplifier) 2C
Green Blue Purple
Relay Output (the electric lock)
IX-DF-P
Orange Yellow
S SE
100 m CAT5e/6
PoE-enabled switch
P P NO COM NC
15m
Image view area IX-DA, IX-DF, IX-DF-P, IX-DF-PI (*)For IX-DF-P, IX-DF-PI
(0k)
(15k)
(-8k) approx.185cm (*190)
approx.185cm approx.65cm
approx.70cm
approx.120cm 150cm
approx.70cm
approx.115cm (*120)
approx.120cm (*125)
150cm
130cm 50cm
approx.190cm (*195)
50cm
50cm
15cm
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Contact Input
• Same features as IX-DF • Compatible with HID® ProxPoint® Smart Card Reader • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 * Card reader not included
2 45
Wiring
2C
IP Direct Audio and Video Door Station for ProxPoint® Reader
150
LAN/PoE
IX-DF
Power-over-Ethernet (IEEE 802.3af Class 0) Communication Open voice hands-free communication Camera 1/4-inch color CCD Minimum illumination 5 Lux Surface-wall mount (directly to wall) Mounting Material Front panel: fire-retardant resin Main unit: flame resisting PC+ABS resin
50cm
IX-DF-PI
IP Direct Audio and Video Door Station for iCLASS® Reader
approx. 95 cm
• Same features as IX-DF • Compatible with HID® iCLASS® Smart Card Reader • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1 * Card reader not included
44
IP Network Audio - Video Intercom System IP Addressable Emergency Stations: Mix and match unlimited
Master station Emergency Wall BoxesFeatures (optional)
• Light cage with
IX-MV beacon / strobe light
Direct Audio lettering and •IP “ASSISTANCE”
Video Master Station Series Emergency Station • Stainless steel Unit dimensions • Wall mount • Compatible with any IX
Series Emergency Station
• Stainless steel
Wiring
• Wall mount
• PoE
• PoE
• PoE
• Fixed camera
• Lettering and Braille signage
• Lettering and Braille signage
• Lettering and Braille signage
• LED call status indicator
• LED call status indicator
• LED call status indicator • Dual call buttons • 2 Form C relay outputs
189 162
• Stainless steel • Weather resistant
2C
Relay output • Flush mount • Back box included
• Dual call buttons IX-MV • 2 Form C relay outputs 100 m • Stainless steel CAT5e/6 • Weather resistant L • Flush mount • Back box included
LAN/PoE
IS‑WBCA*
(can call up to 20 master stations at one time) Specifications (IX-MV) • Directly connectable to an IP network Power source Power-over-Ethernet • 3.5-inch display for operation and video monitoring (IEEE 802.3af Class 0) • A variety of display modes designed for assisting your Communication Hands-free/Push-to-talk Handset:Full-duplex/Push-to-talk operation Monitor 3.5-inch color LCD monitor • Hands-free, push-to-talk or handset audio communication • Direct voice call from master station to another station Mounting Desktop use (with or without desktop stand) or wall-mounting • System settings are possible on the connected PC Material Flame resisting ABS resin • Various setting items for customizing your master station • Video image adjusting function • Call or communication transferring to another master IS‑WBHA* station • Light hood with to a group or all stations • Paging beacon / strobe light IX‑DF‑2RA IX‑SS‑2RA IX‑SS‑RA • Monitoring a single station IP Addressable IP Addressable IP Addressable • “ASSISTANCE” lettering • Power supply by the PoEVideo Emergency Station Audio Emergency Station Audio Emergency Station • Compatible with any IX
L
38 59
250
• Light cage with
beacon / strobe ligh • “EMERGENCY” lettering • Compatible with any IX Series Emergency Station • Stainless steel • Wall mount
• Light hood with
• Directly beacon / strobe lightconnectable to an IP network • Door lettering release output • “EMERGENCY” • Compatible withindicator any IX active while calling, talking, and • LED Series Emergency Station releasing the door • Stainless steel • System settings are possible on the connected PC • Wall mount
Polarized
• 2 Form C relay outputs • Stainless steel
PoE-enabled • Weather resistant
switch
• Flush mount • Back box included
Contact Input
Specifications (IX-BA) Power source
Power-over-Ethernet (IEEE 802.3af Class 0)
Communication
Open voice hands-free communication
Mounting Material
Surface-wall mount (directly to wall) Front panel: Fire-retardant resin Main unit: flame resisting PC+ABS resin
• Calling up to 20 preprogrammed master stations all Emergency Station Features together Fixed camera provides clear visitor identification (video station) • Power supply by the• PoE
System Features
Unit dimensions
• Scalable system is easy to expand - mix and match an infinite (∞) IX-BA IX-SS number of emergency stations, and master stations! • All‑in‑one communication system to control video entry and access control • Uses new or existing CAT‑5e or CAT‑6 network infrastructure
Wiring
IX-SS
IP Direct Audio Door Station
PS‑2420
24V DC, 2A
PowerOutput Supply Audio (to paging amplifier)
*Power supply required for beacon / strobe light with Wall Box Relay Output 2 wires
• Stainless steel • PoE - 802.3af • Flush mount • Mounting box included • Input/Output : Contact input X 1 Relay output X 1 Audio output X 1
265
129
Emergency Towers IX-BA Please contact Aiphone IP Direct Audio Door Station for more details.
Contact Input
(multicast support recommended) 23 96.8 • Program system functions via Support Tool (recommended) 42 or browser • IP addressable stations provide easy network communication • 24/7 streaming from video emergency station 150 2 45 • ONVIF compliant video output • Integration with Lenel® OnGuard® IX-BA • View third party IP cameras from IX-MV master stations IX-SS 100 m • Forward missed calls automatically CAT5e/6 • Paging with two2C priority levels Brown PoE-enabled switch S • Priority call queueing Polarized Red SE • Transfer door calls to any master station Shielded wire Orange • Standard door release wiring to emergency station or to RY-IP44 for added security P Yellow
2C
(the electric lock) 15m
45
S SE
LAN/PoE
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Audio door stationIS‑WBHE* IS‑WBCE* Features
2C
• Single call button
Green Blue Purple
P NO COM NC
* Use existing 2-wire LE Series or NE Series Audio Door / Sub Stations!
IX‑1AS
2-Wire Audio Door / Sub Station Network Adaptor • Supports 1 LE Series or
NE Series Door / Sub Station
Accessories
IX‑10AS
2-Wire Audio Door / Sub Station Network Adaptor
• Supports up to 10 LE Series
or NE Series Door / Sub Stations
KAW‑D
30˚ Angle Box for IX‑DA or IX‑BA g P.97
IP Addressable Master Station: Select unlimited (can call up to 500 door stations, emergency stations, or master stations) IX‑MV
IP Addressable Video Master Station • 3-1/2" LCD screen
• Hands‑free communication
with handset for privacy • Wall or desk mount • 500 station address book capacity
SBX‑ISDVF
SBX‑ISDVFRA
EL‑12S
RY‑IP44
Surface Mount Box for IX‑DF, IX-DF-P, IX-DF-PI or IX‑SS g P.97
IP Input / Output Relay Adaptor
(requires PS-1225)
Specifications Power Source PoE (802.3af) Network Interface Hardwired Stations: 10 BASE‑T / 100 BASE‑TX Ethernet (RJ-45) Network Protocols IPv4, IPv6, TCP, UDP, SIP, HTTP, HTTPS, RTSP, RTP, RTCP, IGMP, MLD, SMTP, DHCP, NTP, DNS Bandwidth Usage G.711: 64Kbps x 2 per video call, 64Kbps per monitor H.264: 24Kbps ~ 2,048Kbps Video Stream ONVIF Profile S Communication Hands‑free (full-duplex), push‑to‑talk (simplex), or handset (full-duplex) Door Release Programmable dry contact, 24V AC/ DC, 500mA – use EL‑12S or use RY‑IP44 with 4 multipurpose relays Wire Type CAT‑5e or CAT‑6 Distance Door Station or Emergency Station to Network Node: 100m
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Electric Door Strike g P.98
Surface Mount Box for IX‑DF‑2RA, IX‑SS‑2RA, or IX‑SS‑RA g P.97
Master Station to Network Node: 100m
46
Security IP Video Intercom System IS IS Series is a network-based IP intercom system that can make centralized security management simple and easy. Ideal for both small and large facilities.
Used as IP network system IS Series can be used as a local network security system in a facility, or as an IP network security system that can manage more than one facility from a control center.
IP network system image Hardwired network system
INTEGRATED SECURITY & COMMUNICATION SYSTEM
IS-IPMV
The Audio Sub Station is available. You can choose the Audio Sub Station. The Audio Sub Station can be selected from 3 types, a handset type or hands-free type.
47
Hardwired network system
Your PC can be used as the Master Station (IS-SOFT). You can use your PC just like the Master Station by installing the IS software. * It may not be available depending on your PC or OS version.
IS-RS
IS-SS
IS-SS-2G
With conventional series
Panoramic wide angle view and Zoom & PanTilt for higher security To provide effective security, IS series features a wide angle camera that enables you to see an innovative panoramic view! People standing on sides and people of all heights can be easily identified.
170k viewing angle
The IS Series features a wide angle camera with PanTilt & Zoom function.
Innovative Wide View of Approx.
170k
Other Functions Schedule Chime
Customize Sounds
Forward Unanswered Calls Automatically
Transfer Video Calls
Emergency Broadcasts
Browser Based Set-up
Create zones easily to broadcast emergency announcements quickly.
Simply use a browser to get on line and set-up, change, or customize the IS systems.
Create Unique System Settings
Paging
Program daily Chime by day, week, month, Create different schedules for holidays, breaks, or after hours. If a master station is not answered, have the calling forwarded to another master station.
Hardwired system
IP system
20 160 X
/site
Master Stations
IS-MV Local IP system system
20 32
X
/site
IP Master Stations
IS-IPMV
Hardwired system
X
20 32
IS-IPDV
Video Door /site Stations
Hardwired system
/site
IP Door Stations
IP system
120 960 X
IS-DVF
Local IP system system
X
You can make a paging from the Master Station to other Master Stations, Door Stations, and Room Sub Stations.
IP system
20 160 IS-DV
Call-ins from a video door station can be transferred to any standard or PC master station on the network for easy identification.
IS-RS
IS-SS
Local IP system system
20 31
X
/site
Audio Stations
/site
PC Master Stations Application
IS-IPDVF
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Save system settings, then export and upload them to another system.
Load up to 15 Pre-recorded messages or sound source.
IS-SOFT
The maximum number of each unit connectable to a standard (IP) system differs from the system configuration. * Depending on combinations, the number above may not be applied.
48
Security IP Video Intercom System System Configuration WAN system
Site.1
Site.2
IS-IPMV PS24
IS-SOFT
IS-IPDV
IS-IPMV
100m
PS24
100m
Hub
IS-SOFT
PS24
Hub
100m
Router
Router
Internet
Router
Site.4
Hub
Hardwired system
INTEGRATED SECURITY & COMMUNICATION SYSTEM
IS-IPC
Hardwired system IS-PU
10m
Hardwired system
IS-IPC
IS-CCU
IS-PU IS-CCU
IS-PU
150m
300m
IS-MV
IS-DV
IS-MV
IS-DV
IS-DV
300m
IS-MV
300m
IS-PU
300m
IS-RS
IS-MV
49
100m
IS-DV
300m
IS-SS
IS-RS
IS-SS
Site.3
WAN system LAN system Hardwired system
IS-IPMV PS24
IS-IPMV PS24
IS-SOFT
IS-IPDV
Site
PS24
x Max.32
Hub Router
Site.5
Router
Hub
Site.. 100m 100m
IS-IPC
IS-PU IS-CCU
IS-IPMV
IS-IPDV PS24
IS-PU
IS-MV
IS-DV
IS-MV
IS-DV
IS-RS
PS24
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Hardwired system
Router
IS-SS
PS24 : PS-2420 IS-PU : IS-PU
50
Security IP Video Intercom System System Configuration Site system WAN system
Internet
LAN system Hardwired system
Router
Site
Hub
100m 100m
Hardwired system
100m PS24
100m PS24
IS-IPC
INTEGRATED SECURITY & COMMUNICATION SYSTEM
10m
IS-IPMV
IS-IPDV
IP master station
IP door station
IS-PU
IS-CCU
~Max.32 IS-PU
150m
300m
Hardwired system
x Max.8
IS-MV
IS-MV
~Max.32
~Max.31
Up to 32 IP units (including the IP control unit(s)) can be connected in a site.
300m
Master station
300m
PC IP master station
IS-DV
IS-RS
300m
IS-SOFT
IS-DV
~Max.160
Video door station
~Max.160
Audio station
~Max.960
300m
IS-SS PS24 : PS-2420 IS-PU : IS-PU
51
System Configuration Hardwired system
Timer IS-MV
IS-CCU
Max.4
or
IS-PU
or
or
or
Monitor
CD player
IS-DV
IS-DVF
IS-SS
IS-SS-2G
IS-RS
Max.4
PA amplifier PA speaker IS-RCU
Max.4
IS-SCU
Max.2
PA amplifier
PA amplifier IS-PU
PA speaker
IS-PU
IS-RS
or
IS-MV
IS-SS
Max.8
IS-DV
or
IS-DVF
Max.30
or
IS-SS
or
IS-SS-2G
Max.8
PT
8d speaker
Call button
Strobe light
Monitor
Audio recorder
EL-12S PT : AC transfarmer IS-PU : IS-PU
Maximum number of each unit connectable to a hardwired system Category Model name Type IS-CCU Central control unit IS-SCU Add-on control unit Control unit IS-RCU Room sub control unit IS-MV Color monitor master station Master station Vandal resistant video door station IS-DV (surface-mount) Sub station
IS-DVF
Vandal resistant video door station (flush-mount)
IS-SS(-2G)
Vandal resistant door station (flush-mount)
IS-RS
Room sub station*1
Max. number 1 2 4 20
IS-RS
INTEGRATED SECURITY & COMMUNICATION SYSTEM
or
PA speaker
20
120
*1: You can use vandal resistant door stations (lS-SS or lS-SS-2G) instead of room sub stations (lS-RS).
52
Security IP Video Intercom System IP Master station
IS-IPMV
IP master station w/Wide and Zoom & PanTilt color monitor
Features
Specifications (IS-IPMV)
• Directly connectable to an IP network • 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, press-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Zoom/wide and pan & tilt video monitoring function • Video image adjusting function • Call or communication transferring to another master station • Paging or chime paging to the registered zones and / or stations • Monitoring a single station or scan-monitoring up to 20 pre-programmed stations • Either power supply unit (PS-2420) or PoE
Power source Current consumption
PS-2420, or PoE Max. 65mA (PoE) Max. 130mA (when power supply unit is used) Communication Handset: simultaneous communication (When press-to-talk (PTT) is not set) Hands-free: auto-voice actuation or Press-to-talk (PTT) Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin
Wiring
Unit dimensions
IS-IPMV
A+ A2
Audio output 2C 15m
DC24V
189 162
LAN/PoE
100m
38
IP Video door station
59
+ -
Features
Unit dimensions
265
Wide and Zoom & PanTilt Vandal resistant IP video door station, surface mount
105
Switch (HUB)
+ -
Polarized
Specifications (IS-IPDV, IS-IPDVF) Power source Current consumption
PS-2420, or PoE Max. 85mA (PoE) Max. 160mA (when power supply unit is used) Communication Open voice hands-free communication Camera 1/4-inch color CMOS Minimum illumination 5 Lux Camera angle Wide: approx. 170k (horizontal) IS-IPDV: Surface-wall mount Mounting (directly to wall) IS-IPDVF: Flush-mount Material Front panel: aluminum die-cast (IS-IPDV) stainless steel(IS-IPDVF) Main unit: flame resisting PC+ABS resin
Image view area Refer to the descriptions for the image view area. m P.10
28 150
45
Wiring IS-IPDV
IS-IPDVF
PT
CAT5e/6
Switch (HUB)
NC COM
NO
DC24V
AC transformer
Wide and Zoom & PanTilt Vandal resistant IP video door station flush mount
100m LAN/PoE
Electric door lock (N/O or N/C)
+ -
+ -
Polarized
Power supply PS-2420
15m 10m PT
53
Power supply PS-2420S / UL
Handset Connection
• Directly connectable to an IP network • Approx. 170k range wide view video camera • Door release output • Directory card with backlight • White light LED to illuminate the visitor automatically at night • System settings are possible on the connected PC • Calling up to 20 preprogrammed master stations all together • Remote site calling and communicating capability • Either power supply unit (PS-2420) or PoE
IS-IPDV
CAT5e/6
15m
Handset
215
INTEGRATED SECURITY & COMMUNICATION SYSTEM
250
RJ45
: AC transformer
PC application IS-SOFT
PC application
PC monitor
Features
System requirements
• PC software with full master station functions • 7 languages (English, French, Spanish, German, Dutch, Italian & Japanese) are selectable for displaying windows • Various settings are possible from 9 setting windows • Play window for searching for and playing back recorded files • Up to 24 speed dials are available • Records video and audio from video door stations • A still picture or video of visitor can be recorded • Either headset (not included) or handset (not included) can be used for communication • Hands-free or press-to-talk communication is possible with a headset
OS
Video & Audio communication with entrance side by PC
Windows XP Home/Professional (SP3)/32-bit version, Windows Vista Ultimate/Home/Business/Enterprise (SP2)/ 32-bit version/64-bit version Windows 7 Home Premium/ Professional/Enterprise/Ultimate/32-bit version/64-bit version Windows 8/Pro/Enterprise/32-bit version/64-bit version PC system Processor: 2 GHz or faster requirements System memory (RAM): 1 GB RAM or more Hard disk: 10 MB or more (additional space is needed for recording) Sound card: 8-bit full duplex, Direct Sound compatible Display: 800 x 600 or higher 1024 x 768 or higher 1920 x 1200 or higher Run-time: Microsoft ®.NET Framework 4.0 or later Network: 10BASE-T/100BASE-TX Ethernet Protocol TCP/IPv4, UDP/IPv4, TCP/IPv6, UDP/IPv6, SIP, Others Network bandwidth 320 k to 8 Mbps
Wide and Zoom & PanTilt control from PC Wide and Zoom
PanTilt on Zoom mode
WIDE IMAGE
Talk button VISITOR
ZOOM IMAGE
Wide and Zoom & PanTilt button
Door Station
Unlock the door after verifying visitor identity
Room to room communication with master station
Unlock
Call button
IP Control unit
IS-IPC
IP control unit
Unit dimensions
Features
Specifications (IS-IPC)
• Configures a standard (IP) system connecting with an IP network • Connectable with either a central control unit (ISCCU) or room sub control unit (IS-RCU) • System settings are possible on the connected PC • Chime and transfer schedule can be set • System setting data can be downloaded or uploaded • Time correction function synchronized with a PC or NTP server • Daylight saving time is available • Either rack-mounting (into 19-inch rack) or wallmounting is possible
Power source
48V DC (supplied from IS-PU)
Current consumption Max. 105mA Talk channels • 2 talk & 2 constrained video Video channels, channels,1 chime, other channels Central control unit Room sub control unit LAN Mounting rack-mount Material
Max. 1 Ethernet (10 BASE-T, 100 BASE-TX) (19-inch, 2U rack) or wall-mount Steel plate
Wiring PBX/CO (North America only)
425
Switch/hub 10BASE-T 100BASE-TX IS-CCU IS-RCU
CO
280
TELEPHONE
IP1
IP2
100m
LAN IP3
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Door release button
DC48V
ETHERNET
IS-CCU IS-RCU
10m
IP1
IP2
IP3
10m
10m CAT5e/6 (x3)
85
CAT5e/6 (x2)
or
480
IS-RCU
IS-CCU
IS-PU
54
Security IP Video Intercom System Master station
IS-MV
Master station w/Wide and Zoom & PanTilt color monitor
Features
Specifications (IS-MV)
• 3.5-inch display for operation and video monitoring • A variety of display modes designed for assisting your operation • Hands-free, press-to-talk or handset audio communication • Direct voice call from master station to another station • System settings are possible on the connected PC • Various setting items for customizing your master station • Zoom/wide and pan & tilt video monitoring function • Video image adjusting function • Call or communication transferring to another master station • Paging or chime paging to the registered zones and/or stations • Monitoring a single station or scan-monitoring up to 20 pre-programmed stations • Remote site calling and communicating capability (required IS-IPC)
Power source
Supplied from the central control unit or add-on control unit Communication Handset: simultaneous communication (When press-to-talk (PTT) is not set) Hands-free: auto-voice actuation or Press-to-talk (PTT) Monitor 3.5-inch color LCD monitor Mounting Desktop use (with or without desktop stand) or wall-mounting Material Flame resisting ABS resin
Wiring
Unit dimensions
Recorder, etc.
Monitor, etc.
300m
IS-MV
CAT5e/6 M
IS-CCU
189 162
15m
or V V A A
IS-SCU
59
300m
Features • Approx. 170k range wide view video camera • Door release output • Directory card with backlight • White light LED to illuminate the visitor automatically at night • Calling up to 20 pre-programmed master stations all together • Remote site calling and communicating capability (required IS-IPC)
Unit dimensions
Wide and Zoom & PanTilt Vandal resistant video door station, surface mount
265
IS-DV
215
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Video door station
105
Specifications (IS-DV, IS-DVF) Power source
Supplied from the central control unit or add-on control unit Communication Open voice hands-free communication Camera 1/4-inch color CMOS Minimum illumination 5 Lux Camera angle Wide: approx. 170k (horizontal) IS-DV: Surface-wall mount Mounting (directly to wall) IS-DVF: Flush-mount Material Front panel: aluminum die-cast (IS-DV) stainless steel(IS-DVF) Main unit: flame resisting PC+ABS resin
Image view area Refer to the descriptions for the image view area. m P.10
28 150
45
Wiring IS-DV IS-DVF
Electric door lock (N/O or N/C)
PT
IS-DVF
Wide and Zoom & PanTilt Vandal resistant video door station flush mount
300m
D
AC transformer
55
CAT5e/6
15m
38 250
V ID E O O UTPUT A U D IO O UTPUT
NC
or
IS-CCU
COM
NO
10m
IS-SCU
Audio station
Features
Unit dimensions
265
199
• Calling up to 20 pre-programmed master stations all together • Remote site calling and communicating capability (required IS-IPC) • Electric door strike can be connected. • External speaker can be connected (IS-RS only) • Option input and option output (IS-RS and IS-SS-2G)
40 116.5
64
120
2
150
45
120
IS-RS
Room sub station
47
Specifications (IS-RS) Power source
Supplied from the central control unit, add-on control unit or room sub control unit
Specifications (IS-SS, IS-SS-2G)
Communication
Handset: simultaneous communication Hands-free: auto-voice actuation or Press-to-talk (PTT) Surface-wall mount (directly to wall or electrical box)
Power source
Supplied from the central control unit, add-on control unit or room sub control unit
Communication Mounting
Open voice hands-free communication Flush-mount
Material
Front panel: stainless steel Main unit: flame resisting PC+ABC resin
Mounting Material
Flame resisting ABS resin
Wiring IS-SS
Electric door lock (N/O or N/C)
Vandal resistant door station, flush mount
AC transformer PT
300m
NO
IS-RS
15m External speaker
Vandal resistant door station, flush mount 2-gang mounting
Control unit
IS-CCU
Central control unit
IS-SCU
Add-on control unit
Contact input (Sensor, etc.) Contact output (Electric door strike, strobe light, etc.)
C SP SP
150m
IS-CCU or IS-SCU/RCU
S SE NO COM
Features (IS-CCU)
Features (IS-RCU)
• Configures a local system with up to 2 add-on control units, 4 room sub control units, in total 20 master stations, 120 sub stations and 28 PA outputs • 4 PA outputs, 2 chime inputs, 2 video outputs • System settings are possible on the connected PC • Up to 3 M Bytes of audio files can be uploaded for sound source • Chime and transfer schedule can be set • 3 triggered actions selectable for contact input • 5 trigger conditions selectable for contact output • System setting data can be downloaded or uploaded • Time correction function synchronized with a PC or NTP server • Daylight saving time is available • Either rack-mounting (into 19-inch rack) or wallmounting is possible
• Connectable with up to 30 sub stations • Connectable with either an IP control unit (IS-IPC) or central control unit (IS-CCU) • 4 PA outputs • 4 trigger conditions selectable for contact output • Either rack-mounting (into 19-inch rack) or wall-mounting is possible
Unit dimensions (IS-CCU, IS-SCU, IS-RCU) IS-CCU / IS-SCU / IS-RCU 425
INTEGRATED SECURITY & COMMUNICATION SYSTEM
or
IS-SS-2G
IS-CCU or IS-SCU/RCU
NC COM
280
IS-SS
D
10m
IS-RCU
Room sub control unit
• Adds up to 8 master stations and 8 sub stations in a local system • 4 PA outputs • 4 trigger conditions selectable for contact output • Either rack-mounting (into 19-inch rack) or wall-mounting is possible
85
Features (IS-SCU)
480
(IS-CCU)
56
Security IP Video Intercom System Specifications (IS-CCU) Power source Current consumption Talk channels • Video channels Master station(s) Video door station(s) Audio door station(s) Room sub station(s) Add-on control unit Room sub control unit IP control unit Video output Mounting
48V DC (supplied from the power supply unit)
Wiring
IS-CCU
Contact output (Electric door lock, strobe light, etc.)
PA output (600d)
Contact input
PA amplifter
Sensor, etc.
External sound source such as CD player, etc.
Monitor 1, video recorder 1
Max. 0.8A Local system: 2 talk & 2 video channels, 1 chime
PC for setting the system
Monitor 2, video recorder 2
AC transformer P T
Max. 4 P1
P2
P3
P4
L1
L2
PA OUTPUT (600d)
Max. 4
CAT5e/6
L4
L5
L6
L7
L8
S1 E
S2 E
S3 E
B1
S4 E
CONTACT INPUT
B2
V1
V2
IS-SCU
2C X 1
3C X 1
4C X 1
M1
M3
D1
D3
1MX 1
1MX 3
2MX 2
IP 1
1C X 2
2C X 2
3C X 2
4C X 2
M2
M4
D2
D4
1MX 2
2MX 1
2MX 3
IP 2
CAT5e/6
ETHERNET
IS-IPC
1C X 1
CAT5e/6
LA N
VIDEO OUTPUT
CHIME INPUT (600d)
VIDEO/AUDIO DOOR/SUB STATION
MASTER STATION
IS-RCU
Max. 2 Max. 4 Max. 1 NTSC BNC (Video channel 1,2)
L3
CONTACT OUTPUT (AC/DC24V 0.5A)
DC48V IP 3
CAT5e/6
CAT5e/6
CAT5e/6 (x3)
Rack-mount (19-inch, 2U rack) or wall-mount
CAT5e/6 (x3)
or
* The system setting tool is compliant with Windows XP, Windows VISTA and Windows 7.
IS-RCU
Specifications (IS-SCU)
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Power source
48V DC (supplied from the power supply unit)
Current consumption Talk channels • Video channels Master station(s) Video door station(s) Audio door station(s) Room sub station(s) Video output
Max. 1.2A Local system: 2 talk & 2 video channels, 1 chime Max. 8
Mounting
IS-SCU
IS-MV
IS-SCU
IS-RS/IS-SS(-2G) IS-DV/IS-DVF
PA output (600d)
IS-IPC
Contact output (Electric door lock, strobe light, etc.)
PA amplifter
Monitor 1, video recorder 1
Monitor 2, video recorder 2
BNC connector AC transformer
BNC connector
PT
BNC conne ctor
Max. 8 P1
NTSC BNC (Video channel 1,2) Rack-mount (19-inch, 2U rack) or wall-mount
P2
P3
P4
L1
PA OUTPUT (600d)
IS-PU
L2
L3
L4
V1
V2
VIDEO OUTPUT
CONTACT OUTPUT (AC/DC24V 0.5A)
MASTER STATION
BNC conne ctor
VIDEO/AUDIO DOOR/SUB STATION
IS-CCU
M1
M3
M5
M7
D1
D3
D5
D7
MX 1
M2
M4
M6
M8
D2
D4
D6
D8
MX 2
MX 3
DC48V
Specifications (IS-RCU) Power source
48V DC (supplied from the power supply unit)
CAT5e/6
CAT5e/6
CAT5e/6 CAT5e/6 (x3)
Current consumption Max. 1.8A Talk channels Local system: 2 talk channels, 1 chime
or
Audio door station(s) Room sub station(s) Max. 30 Mounting
Rack-mount (19-inch, 2U rack) or wall-mount
IS-MV
IS-CCU IS-DV/IS-DVF IS-RS/IS-SS(-2G)
IS-RCU
IS-PU
Contact output (Electric door lock, strobe light, etc.)
PA output (600d) PA amplifter
AC transformer
P1
P2
P3
P4
PT
L1
PA OUTPUT (600d)
L2
L3
L4
CONTACT OUTPUT (AC/DC24V 0.5A) IS-CCU/ IS-IPC
AUDIO DOOR/SUB STATION C1
C3
C5
C7
C9
C 11
C 13
C 15
C 17
C 19
C 21
C 23
C 25
C 27
C 29
C X 1/IP 1
C2
C4
C6
C8
C 10
C 12
C 14
C 16
C 18
C 20
C 22
C 24
C 26
C 28
C 30
C X 2/IP 2
CAT5e/6
CAT5e/6
DC48V
CAT5e/6 (x2) CAT5e/6 (x2)
or
IS-RS IS-SS(-2G)
or
IS-IPC
IS-CCU IS-PU
57
Power supply Unit dimensions
Specifications (PS-2420) Input voltage & Capacity
PS-2420S
52
90
100-240V AC, 50/60Hz 60W/100-125VA 24V DC, 2A
PS-2420
167
Output voltage
Features
Unit dimensions
• Either rack-mounting (into 19-inch rack) or wall-mounting is possible by using the optional IS-RACK Power source AC 100 - 240V, 50/60Hz. Power consumption 120W
IS-PU
Output voltage Output current Mounting
Power supply unit
Material
265
IS-PU
Specifications
DC 48V 2.1A Wall-mount or rack-mount (IS-RACK) Steel plate
130
Item Features
Video Door Station
Audio Station
Master Station
Hands-free
✓
✓
-
-
Handset
-
✓
Talk transfer
-
-
Video identification at door call
-
-
Answering to door call
-
-
Door release (contact output)
-
-
Call forwarding on door call
-
-
Absence transfer on door call
-
-
Zone page to door station
-
-
Direct Voice call and talk-back
-
-
Monitor of door camera image / audio
-
-
✓ ✓
✓ ✓
Zone paging
-
-
Zone chime of external sound source
-
-
Zone chime of internal sound source
-
-
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓
✓
-
-
✓
Press-to-talk
Answering to master call Answering to PC master call
E-mail at set trigger (small number of addresses) Video output
-
IP Video Door Station IP Master Station
✓
PC application
-
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
✓
-
-
-
-
-
-
✓ ✓ -
✓ ✓ -
✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Functional Specification
58
Integratable Audio & Video Security MASTER
8
DOOR
120 AX Central exchange unit
Master station
AX-084C
Central exchange unit, 4 masters and 8 doors
AX-8MV
8-call color monitor master station
AX-248C (Photo)
AX-8M
Central exchange unit, 8 masters and 24 doors
8-call audio master station
AX-8MV-W (white)
AX-320C
Add-on exchange unit, 32 doors
INTEGRATED SECURITY & COMMUNICATION SYSTEM
AX-16SW
16-call add-on selector
Power supply PS-2420
AX-8MV, AX-16SW
Features l Up to 120 video entrance stations and 8 master stations l All wired on CAT5e, homerun cabling l Total hands-free, auto-voice actuation, communication or Press-to-talk operataion l Two talk channels and two video channels. l Communication privacy l Masters available with 3.5-inch color TFT LCD l Selective door release l Master-to-master selective calling and All Call l Standard or Priority call levels from door stations l Scan monitoring: Hands-free audio/visual monitoring l Video output from CEU and AX-8MV l Integrate with CCTV, Access control etc. l PC interface for programming and event logging l Rack or wall mountable CEU l Compatible with IE Series door stations l Optional features: headset, footswitch, and PC remote control
m P.100
Communication network
AX-DV
AX-8MV
AX-8MV AX-DVF
Video signal
PC programming
AX-DM
Monitor
Calling & communication (w/video from door) Door release
59
Door station
Lineup
EL-12S
AX-DV
Color video door station surface mount
Electric door strike m P.98
AX-DM
AX-DVF
Audio door station Mullion type
Color video door station flush mount
AC-10S
Access control keypad, surface mount m P.95
IF-DA
Audio door station
AX-DV-P
AX-DVF-P
AC-10F
Color video door station w/space for embed proximity reader flush mount
Access control keypad, flush mount m P.95
IE-JA
Audio door station
System Integration
Cabling 300m
Video signal
300m
CAT5e
AX-8MV
Security Integration Software
AX System
System log
AX-8MV
Remote door release
AX-DV AX-084C
Switch camera
PC
Video signal
CCTV System
AX-084C VCR
Camera
Monitor
AX-8MV
AX-DVF-P
CAT5e CAT5e CAT5e
Calling & Communication with video
Door release
AX-DVF
PS24 PS24
Door release history
CAT5e
Remote door release
Card ID
Access Control System
AX-DM
Monitor
RS232C Door release
AX-DV
Access Control System
PC
INTEGRATED SECURITY & COMMUNICATION SYSTEM
Color video door station w/space for embed proximity reader surface mount
Camera CCTV Switcher
Monitor VCR
60
Integratable Audio & Video Security Wiring 300m
300m
AX-8MV Cat5e
AX-DV
Cat5e
M
2
AX-248C AX-DVF
M
2
2
2
AX-DM
Door #1 AX-DV
Door #2 AX-DVF
INTEGRATED SECURITY & COMMUNICATION SYSTEM
61
N N AX-8M Cat5e
Cat5e
M
2
Master #1 AX-8MV
Cat5e RJ-45
EL-12S Cat5e
AX-8MV
Cat5e
Cat5e
Brown Red Yellow Orange Green Blue
Cat5e RJ-45
H AX-248C
PC
Master #2 AX-8MV
RJ-45 RJ-45
H EL-12S
Door #24 AX-DM
Red Brown
3(White green) 6(Green) 7(White brown) 8(Brown)
1 2 4 5
N N
Cat5e Cat5e
Master #8 AX-8M
Cat5e EL-12S
RJ-45
H
N : PS-2420 H : AC transformer
Mounting locations
Master station
Video door station
Install the video master station in a place where the screen is not exposed to direct sunlight.
Do not install a video door station in any of the following locations where lighting or the ambient environment could impact the display on the video master station due to the characteristics of the door station's camera. 1. Locations subject to direct sunlight 2. Under street lights or door lights 3. Other locations subject to strong lighting conditions
Video + Video IER-2 Foot switch
Components
AX-DV
AX-8MV (AX-8M audio only)
AX-16SW
Number of master stations
Number of add-on selectors per master
1~8
up to 4
9 ~ 24
AX-DVF
AX-DM
Number of door stations
AX-084C or AX-248C
AX-320C
Number of central exchange unit
Number of add-on exchange units
AX-084C
AX-248C
-
1
-
-
up to 8
1
-
1
-
25 ~ 40
up to 4
2
1
-
1
41 ~ 56
up to 8
3
-
1
1
57 ~ 72
up to 4
4
1
-
2
73 ~ 88
up to 8
5
-
1
2
89 ~ 104
up to 4
6
1
-
3
105 ~ 120
up to 8
7
-
1
3
NOTE: Use the AX-248C for systems with more than 4 master stations (may effect the required quantity of AX-320C). 2 pcs of power supplies are required for video system.
Image view area
Unit dimension AX-8MV(-W)
• AX-DV, AX-DVF AX-DV-P, AX-DVF-P
AX-8M
185cm
★
175
175
★
50cm
120cm
★
150cm
95cm
★
50cm 194
63
AX-16SW
63
194
AX-320C
AX-084C, AX-248C
88 85
Calling
63
AX-DV-P
Communication
AX-DVF
245
195
AX-DV
100
Power source Power supply Current consumption
246
86
25 100
AX-DVF-P
25
Video monitor Scaning lines Night viewing 146
2 45
130 160
295
Door release contact Outside video output
IF-DA
AX-DM
98
1-gang Wiring Wiring distance
28
IE-JA
146
22.5
115
43
24V DC, 2A (Two Power supplies required per video system) PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5-inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300 m (CAT5e) CEU to master: 300 m (CAT5e)
2-gang
2 45 116
approximate
Specifications 420 426
88 85
175
420 426
★
INTEGRATED SECURITY & COMMUNICATION SYSTEM
65cm
10
62
AUDIO ENTRY SECURITY Audio based security intercoms for those who want a simple security solution.
DB
Hands-Free
SYSTEM
Hands-Free Communication in Any Place. 2-Wire System for Simple Installation.
AUDIO ENTRY SECURITY
Lineup Hands-free Two-Wire Electric Lock Door Phone
Two-Wire Electric Lock Door Phone
DB-1MD
C-123L/A
DA-1AS & DA-4DS
P64 P65
Chime Tone Intercom
P67 P68
Chime Tone Intercom
IE-1AD(U)
P69
Chime Tone Intercom
IE-1GD(U)
P70
63
Chime Tone Intercom
Chime Tone Intercom
IE-2A2DU
P71
IE-8MD
P72
P73
Hands-free Two-Wire Electric Lock Door Phone DOOR
ROOM
5 DB-1MD
1
Request to exit/entry button
Lineup
Kit box (DBS-1AK)
2
2
4
4 2
Polarized
4
4 2
PT
DB-1SD
PT
DA-1DS
Door station, silver
DB-1MD
Master station
2
Sub master station
EL-12S
PT
DB-1SD
DB-1SD
AC-10S
Electric door strike m P.98
DB-1SD
Access control keypad, surface mount m P.95
2
IER-2
AC-10F
Call extension m P.101
Access control keypad, flush mount m P.95
IER-2
Call extension
Kit box DBS-1AK
PT : AC transformer
16VAC1500/5
m P.99
Features
Wiring 100m / 1.0mma
310m / 1.0mma 2
M
DA-1DS
DB-1MD
2 P
4
DB-1SD
P
4
DB-1SD
P 2
2
4
DB-1SD
P
EL-12S L L
B1 B2 B3 B4
D F
D E
DB-1SD 16VAC1500/5
2
2
~ ~
16VAC1500/5
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
OUT B1 B2 B3 B4 IN B1 B2 B3 B4
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
IN B1 B2 B3 B4
~ ~
~ ~
~ ~
~ ~
16VAC1500/5
Option devices (IER-2 etc..)
DB-1SD
DB-1SD
Option lead wires
Press "call" button to ring inside station (s).
Unit dimensions 100
DB-1MD/1SD 80
22
27
Door release Option contact (AC/DC)
185
Wiring 175
16VAC1500/5
P : Polarized
Specifications (DB-1MD, 1SD) Power source AC transformer Communication
DA-1DS
DB-1SD
P 2
16VAC1500/5 16VAC1500/5
DB-1MD
M
4
155m / 1.0mma
Communication network DB-1SD
Door station mounting plate
Wiring distance
16V AC 16VAC1500/5 Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. EL-12S or others (More than (AC) 70d, AC 9.5 ~ 20V) Voltage Max. : 24V, Min. : 1V Current Max. : 1.6A, Min. : 10mA 2 wires, throughout AC trans - Master - Door - Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma)
AUDIO ENTRY SECURITY
l Door release wired from door station, without additional transformer l Two-wire system including door release l Total hands-free communication, auto-voice actuation l Press-to-talk operation available l Up to 5 inside stations l All call for internal communication l User-optional function button l Call tone MUTE with indicator l Call extension sounder l Directory backlighting l Continuous chime tone (approx. 4 seconds)
DA-1DS
DAW-P
DA-1DS DB-1MD 16VAC1500/5
64
Hands-free Two-Wire Electric Lock Door Phone ENTRANCE
TENANT
4 DA-4DS with DB-1MD
1
Entrance station
Tenant station Tenant 1 2 2
2
DA-4DS
2
4-call door station PT
IER-2
DB-1MD
Call extension
Master station
2
Tenant 2 2
DB-1MD
PT
DA-2DS
2-call door station
DA-4DG
2
4-call door station
Tenant 3 2
DB-1MD
PT
2
Tenant 4 2
PT : AC transformer
16VAC1500/5
DB-1MD
PT
m P.99
Communication network
Wiring 100m / 1.0mma
310m / 1.0mma DB-1SD
DB-1SD
DB-1SD
Tenant 1
DB-1SD
2
DB-1MD
AUDIO ENTRY SECURITY
P
4
DB-1SD
2
M
2
DB-1MD #2
DB-1SD
P
1
D E
M
DB-1SD
2
155m / 16VAC1500/5 16VAC1500/5 1.0mma Tenant 2 Tenant 3 Tenant 4
16VAC1500/5
D E ~ ~
16VAC1500/5
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
OUT B1 B2 B3 B4 IN B1 B2 B3 B4
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
IN B1 B2 B3 B4
~ ~
~ ~
~ ~
~ ~
16VAC1500/5
Option devices (IER-2 etc..)
16VAC1500/5
Option connectors.
DB-1MD #4
65
4 P 2
2
B1 B2 B3 B4
L L
DB-1MD #3
4
Tenant 1 EL-12S
DA-4DS
DB-1SD
P 2
P
DB-1MD #1
DA-4DS
4
2
D E
Tenant 2
3
D E
Tenant 3
4
D E
Tenant 4
P : Polarized
Lineup
4
4
4
4
EL-12S 2 2
DB-1SD
Sub master station
PT
Electric door strike m P.98
2
2
DB-1SD
DB-1SD
DB-1SD
Call extension m P.98
4 2
2
Same as the above
2
Same as the above
PT
4
Access control keypad, surface mount m P.95
PT
IER-2 4
AC-10S
AC-10F
Access control keypad, flush mount m P.95
4 2
PT
4
DAW-P
4 2
Door station mounting plate
Same as the above
2
PT
Features
Specifications (DA-4DS, G)
l Door release wired from door station, without additional transformer l Two-wire system including door release l Total hands-free communication, auto-voice actuation l Press-to-talk operation available l Up to 5 inside stations in each tenant l All call for internal communication l User-optional function button l Call tone MUTE with indicator l Call extension sounder l Directory backlighting l Continuous chime tone (approx. 4 seconds)
Power source Power supply Communication Wiring
Wiring
DB-1MD/1SD 80
22
185
175
Power source AC transformer Communication
Door release Option contact (AC/DC)
DA-2DS DA-4DS,G 100
Specifications (DB-1MD, 1SD)
27
Wiring distance
16V AC 16VAC1500/5 Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. EL-12S or others (More than (AC) 70d, AC 9.5 ~ 20V) Voltage Max. : 24V, Min. : 1V Current Max. : 1.6A, Min. : 10mA 2 wires, throughout AC trans - Master - Door - Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma)
AUDIO ENTRY SECURITY
Unit dimensions
16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door - Door rlse.
66
Two-Wire Electric Lock Door Phone DOOR
ROOM
1 DA-1ASK
1 Boxed set
Lineup
DA-1ASK
EL-12S
AC-10S
Electric door strike m P.98
Kit box (silver color)
Access control keypad, surface mount m P.95
AC-10F
Access control keypad, flush mount m P.95
DA-1MD
DA-1DS
Master station
Door station silver panel
DAW-P
Door station mounting plate (83.5mm)
PT : AC transformer
16VAC1500/5
m P.99
Features
l Two-wire system including door release l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder
Wiring 310m / 1.0mma 155m / 1.0mma DA-1MD Door station
M
2
2
2
P
Communication network
16VAC1500/5 (1) EL-12S
AUDIO ENTRY SECURITY
Door station
DA-1MD DAR-1
(2)
~ ~
D E
D E
16VAC1500/5 16VAC1500/5
S SE SW SW
M Hold down gCALLh button to ring inside station.
Unit dimensions DA-1MD
Door station 22
200
175
100
89
61
S SE (3)
l Place 16VAC1500/5 inside electrical enclosure and connect to breaker, less than 16A. l Do not use 16VAC1500/5 for any other equipment. l Terminals SW, SW; Dry-closure contact 18V AC, 40mA to connect user-optional function (Gate, Light, Garage, Proximity Access Control, etc.) (1) External device Relay/Controller (2) Door release (16V AC, 20d or more) (3) User-optional function (18V AC, 40mA)
Specifications (DA-1AS, G) Power source Power supply Communication Wiring Wiring distance
67
L L
16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door- Door release 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DA-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma)
Two-Wire Electric Lock Door Phone ENTRANCE
TENANT
4 DA-4DS
1
Entrance station
Lineup
Tenant station
EL-12S
AC-10S
Electric door strike m P.98
DA-2DS
Access control keypad, surface mount m P.95
DA-4DS
2-call door station
4-call door station
AC-10F
Access control keypad, flush mount m P.95
DA-1MD
Master station
AC transformer 16VAC1500/5
DA-4DG
DAW-P
Door station mounting plate (83.5mm)
m P.103
4-call door station
Features
l Two-wire system l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder
Wiring 310m / 1.0mma 155m / 1.0mma DA-4DS DA-4DG
M
2
DA-1MD 2
DA-1MD
DA-1MD
DA-1MD
DA-1MD
DA-4DS, DA-4DG
EL-12S
1 D E 2 D E 3 D E 4 D E
P
2 P
P ~ ~
AC15
~ ~
AC15
16VAC1500/5 D E
P
P
D E P
22
61
(3)
DA-1MD
S SE
DA-1MD
DA-1MD
(1)
DA-1MD
DA-4DS, DA-4DG 2x2
200
175
D E
SW SW
DA-1MD 89
100
~ ~
AC15
Unit dimensions DA-2DS DA-4DS,G
DA-1MD 2 2 AC15 (1)
2x2
2x2
2x2
AUDIO ENTRY SECURITY
Electronic tone. Direct select ring.
~ ~ D E
DA-1MD 2
P
L L
(2)
M
2
P
Communication network
DA-1MD
16VAC1500/5
(1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door release : EL-12S or 16V AC, 20 d or more (3) When a single common power supply is used
Specifications (DA-4DS, G) Power source Power supply Communication Wiring Wiring distance
16V AC 16VAC1500/5 Press and hold down Button to call. 2 wires, throughout system: AC trans - Master - Door - Door rlse. 16VAC1500/5 ~ Door rlse. 110m(0.65mma) 200m(0.8mma) 310m(1.0mma) 16VAC1500/5 ~ DA-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma)
68
Chime Tone Intercom DOOR
ROOM
1 C-123L/A
1 Door station
Master station
Lineup
AC-10S
Access control keypad, surface mount m P.95
C-D
Door station *Not available separately
C-ML/A
Master station
AC-10F
Access control keypad, flush mount m P.95
Boxed set C-123L/A
Chime-Com boxed set
Power supply 6VDC2500/1 or Batteries
EL-12S
Electric door strike m P.98
m P.99
Features
Wiring
l Open voice door answering with door release control l Adjustable communication volume l Automatically turns off l Battery or DC power supply
115m / 0.8mma C-ML/A
C-D 2 NP
M Communication network
AUDIO ENTRY SECURITY
EL-12S
W
L L C-ML/A
C-D
H
H : AC transformer W : 6VDC2500/1
M
Specifications (C-123L/A) Power source Power supply Communication
Unit dimensions C-D
C-ML/A
Wiring
88
83.5
190
120
83.5
Wiring distance
29 130
69
1 E + –
1 E
44
6VDC2500/1 6VDC2500/1 or Batteries gCh(SUM-2) x 4 pcs. Door calls in w/2-tone chime, not adjustable. Press TALK button to reply, release to listen. Power automatically shuts off circuit. 2 parallel wires to door, non-polarized (+ 2 for EL-12S). Master to door 75m(0.65mma) 115m(0.8mma)
Chime Tone Intercom
1 IE-1AD(U)
DOOR
ROOM
1
Door station
Master station
Lineup
EL-12S
Electric door strike m P.98
IF-DA
AC-10S
Access control keypad, surface mount m P.95
Door station m P.71
IER-2
Call extension m P.98
Power supply
AC-10F
Access control keypad, flush mount m P.95
IE-1AD(U)
Master station
12~24V DC power supply 12~16V AC transformer
Features
Wiring
l Chime tone intercom for 2 locations l Door release button l AC or DC power source
360m / 1.0mma IE-1AD(U) IF-DA
IER-2 2 NP 2
M 1 2
Communication network
EL-12S
IF-DA
1 2 L L + –
WH
1 E
IER-2
l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer WH : White(2)
M
Specifications (IE-1AD(U)) Power source Power supply Communication
Unit dimensions IF-DA 130
IE-1AD(U)
98
Door release Wiring
210
83.5
83.5
Wiring distance
12~16V AC, 180mA 12~24V DC, 160mA AC transformer (for IE & EL-12S), PS-1225. Door calls in w/4-tone chime, adjustable. Pick up handset to reply. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized (+2 for EL-12S) IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma)
AUDIO ENTRY SECURITY
H IE-1AD(U)
2
28
80
58
70
Chime Tone Intercom
3 IE-1GD(U)
DOOR
ROOM
1 Door station
Master station
Sub station
Lineup
EL-12S
AC-10S
Electric door strike m P.98
IE-JA
Access control keypad, surface mount m P.95
Door station m P.71
IER-2
AC-10F
Call extension m P.98
IE-1GD(U)
Master station
Power supply
Access control keypad, flush mount m P.95
IEH-1CD
Sub master station
12~24V DC power supply or 12~16V AC transformer
Features
Wiring
l 3-station chime tone intercom with one door l Door release button l All call type room calling l Chime tone cutout at sub station l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-1GD(U) 2
M
Communication network
AUDIO ENTRY SECURITY
1 2
IEH-1CD IE-JA
IEH-1CD 6
6
IER-2 2
2
D1 E1
IER-2
IE-1GD(U) EL-12S
M H
T R C E
T R C E
T R C E
L L
L L
L L
1 E
+ –
IEH-1CD
l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer All Call type calling with pretone & voice
Specifications (IE-1GD(U))
Unit dimensions
Power source IE-1GD(U) IEH-1CD
IE-JA
Power supply Communication
210
83.5
83.5
115 116
Door release Wiring
10
100
71
IEH-1CD
IE-JA
61
Wiring distance
12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V, 550mA (for both IE & EL-12S), PS-1225 Door calls in w/4-tone chime to all stations. Chime can be cut out at sub(s). Pick up any station to reply. Press CALL to call other inside stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires to door, non-polarized. 6 wires in loop, between rooms. IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma)
Chime Tone Intercom DOOR
ROOM
3 IE-2A2DU
2 Door station
Master station
Sub station
Lineup
EL-12S
AC-10S
Electric door strike m P.98
IE-JA
Access control keypad, surface mount m P.95
Door station m P.74
IER-2
AC-10F
Call extension m P.98
IE-2AD(U)
IE-2A2DU
IF-DA
Master station, 2 door releases
Door station m P.74
Power supply
Access control keypad, flush mount m P.95
IEH-1CD
Master station
Sub master station
IEH-1C2D
2 door release
12~24V DC power supply 12~16V AC transformer
Features
Wiring
l 3-station chime tone intercom l 2 door stations w/door release l All call type room calling l Chime tone cutout at sub station l Door selective monitoring at master station l AC or DC power source
360m / 1.0mma IE-JA
190m / 1.0mma IE-2A2DU
2
M2
IEH-1C2D
M2
EL-12S #1 IE-2A2DU EL-12S #2 H
D1 E1 D2 E2 T R C E
T R C E
T R C E
L L
L L
L L
BL
BL
+ –
BL
1 E
IF-DA
BL : Blue(2)
IEH-1C2D
( 1)
All call type voice calling between rooms (*1) Available in IE-2A2DU or IE-2AD(U) w/RY-3DL
Specifications (IE-2A2DU) Power source
Unit dimensions
Power supply
IE-JA 115
IE-2A2DU, IE-2AD(U)
Communication 83.5
10
210
83.5
83.5 210
116
IEH-1CD
130
IF-DA
98
H : AC transformer
83.5 28
100
68
100
61
Door release Wiring Wiring distance
AUDIO ENTRY SECURITY
IE-JA
IER-2 2
2
1 2
IER-2
8
IF-DA
1 2
Communication network
IEH-1C2D
IEH-1C2D 8
12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V AC, 550mA (for both IE & EL-12S). PS-1225 Door calls in w/4- or 2-tone chime to all stations, 45 sec. Chime can be cut out at sub. Pick up any station handset to reply. Press CALL to call other stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized. 6 wires in loop, rooms. IE-2A2DU to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma)
72
Chime Tone Intercom DOOR
ROOM
6 IE-8MD
2
Door station
Master station
Lineup
Sub station
EL-12S
AC-10S
RY-AC/A
Access control keypad, flush mount m P.95
Electric door strike m P.98
IE-JA
Door station m P.71
Access control keypad, surface mount m P.95
AC-10F
External signaling relay m P.98
IF-DA
IE-8MD
Door station m P.71
6-call master
IE-8HD
6-call sub master
Power supply PS-1225 m P.99 PS-1820 m P.99 Features
Wiring
l Expandable to 6-station system l Selective or All Call between inside stations l Door select and monitor button (on IE-8MD only) l AC or DC power source l Selective door release control l Chime tone cutout on inside stations, selectable
360m / 1.0mma IF-DA
M
IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD
2
IE-8HD
IE-8MD
4
4
4
M 1 2
IE-8HD
2
1 2
3
EL-12S
IE-JA
EL-12S
4 IE-8HD
5 IE-8HD
6 IE-8HD
H
T
D1 E1 D2 E2 EL EL SL SL 1 2 3 4 + –
2 1 2 3 4 station # setting 2 4 5 6
3 1 2 3 4
4 1 2 3 4
5 1 2 3 4
6 1 2 3 4
3
4
5
6
4 5 6
4 5 6
4 5 6
4 5 6
H : AC transformer T : PS-1225 U : PS-1820 or AC transformer Internal communication by Selective Call or All Call. Chime tone can be muted at each station selectively.
Unit dimensions IF-DA 130
Power source
83.5 210
98
Specifications (IE-8MD) Power supply
IE-8MD IE-8HD
83.5
AUDIO ENTRY SECURITY
M
M
4
1
1
Communication
28
IE-JA 110 83.5
115 116
73
4
IE-JA 2
Communication network IF-DA
190m / 1.0mma
10
79
Door release Wiring Wiring distance
12~16V AC, 900mA 12~18V DC, 500mA Intercom only; 12V or 18V DC power supply. AC transformer 12V AC, 10VA or 16V AC, 14VA w/no load voltage 20V or less. Intercom + EL-12S; 12V AC, 10VA only Door calls in w/4- or 2-tone chime and LED, 45 sec. Pick up any handset to reply. Press 1 ~ 6 to call other station with pretone and voice or All Call. Single channel, common talk system. Contact rating: 24V AC/DC, 350mA 2 parallel wires, to door. 4 wires in loop, between rooms. IE-8MD to door 150m(0.65mma) 360m(1.0mma) Rooms 75m(0.65mma) 190m(1.0mma)
Audio Door Stations IE/IF Series
Unit dimensions IF-DA
98
160
83.5
AX-DM 130
28 43
IE-JA
Audio door station Mullion type
116
10
120
83.5
AX-DM
IE-SS/A 115
IF-DA
Door station
22.5
120
84
Surface mount station
50
Flush mount station Specifications Wiring Wiring distance
2 parallel wires to master, non-polarized 150m(0.65mma) 230m(0.8mma) 360m(1.0mma)
Features IE-JA
Door station
IE‑SS/A
Audio door station
l Weather resistant audio door stations l Hands-free communication l Call button rings chime or tone at inside station
Some applications l At multiple doors w/TB-AD10
Used for
IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24) TC-M w/TB-AD1 TC-M w/TB-AD10 AX
AUDIO ENTRY SECURITY
74
External Signaling Relays External Signaling Relays
105
RY-ES
41
71
RY‑ES
External Signaling Relay
Specification Power Source RY‑ES: 12~24V DC, 12~16V AC – supplied by Master Station Contact Rating RY‑ES: 125V AC, 1.0A 30V DC, 1.0A
Features (RY‑ES) • •
AUDIO ENTRY SECURITY
75
llows an external device to be triggered A when the intercom is called External device will be activated when the door station calls in
Used with: RY‑ES – AX Series, DB Series, JF Series, JK Series, JO Series, JP Series, or KB Series
INTERCOM SYSTEM Intercom systems for a variety of facilities where effective communication is needed.
Lineup
JP-4MED
Open Voice Intercom
Open Voice Intercom
LEM system
LEF system
Handset Intercom
Handset Intercom
Hands-free Intercom
DB-1MD
Master / Sub Intercom
TC-M
P91l
P85
Security Window Intercom
Handset Intercom
YAZ-90-3W
AT-406
P85
P81l
P79 l
P77
IMU-100
TD-H/B
P86
INTERCOM SYSTEM
7-inch Touchscreen Color Video Intercom
P8 7l
P8 9l
Market-Com
MC-60/4A
P94
76
7-inch Touchscreen Color Video Intercom DOOR
Features
ROOM
8 JP-4MED
4
• • • • •
7-inch touchscreen for operation Hands-free or handset audio communication Zoom/wide and pan & tilt video monitoring function Video image adjusting function Record visitor images both automatically & manually
Door station
Master station 2 2 Cat5e
2 2 2
JP-DV
Wide and Zoom & PanTilt Vandal resistant video door station, surface mount
2
2
2
3 connectors
2
2
PT
JP-4MED
PS24
Hands-free color video intercom master station
RY-3DL
Multiple door release adaptor
or
GT-D
JPEC
Audio door station
JP-DA
JP-DVF*
Wide and Zoom & PanTilt video door station, surface mount
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount
Handsfree module for JP-4MED & JP-4HD
JP-DVF-L
Wide and Zoom & PanTilt Vandal resistant video door station, flush mount (Guidance-enabled type)
INTERCOM SYSTEM
JPTLIIP
Power supply PS-2420 P.100
IP Interface for JP System (compatible with iOS and Android)
* Marine grade option available
Features
Wiring
Internal communication
Refer to P.5 for details
Select a single master station to call.
JP-4HD
JP-4HD
Door station 1
M(OUT)
M (IN)
M(OUT)
A1 A2
1A1 1A2
M(OUT)
M (IN)
~
Individual call
Simultaneously make an announcement to all master stations.
JP-4MED
~
All call
JP-DV
A1 A2
4A1 4A2
*Same as door station 1.
(Up to 7 sub master stations.)
4-pin option connector 12-pin option connector
EL-12S
S S
1 E
IER-2
L1 L1
EL-12S
L2 L2
PT
Audio monitoring of other master stations
Communication network All stations can be set to audibly monitor other master stations.
JP-DV
(Master station) JP-4MED
PS24
(Sub master station) JP-4HD No.3
No.4
~
Monitoring
No.7 No.8
M The design and specifications are subject to change without notice for improvement.
77
• 3 wiring methods selectable (Station-to-station, Homerun, or combined wiring) • 2 internal calls selectable (All call or Individual call) • Audio monitoring of other master stations • Option: 3 sensors connectable to the master station Commercial
Residential
Retail Shops
Factories
Schools
Sub master station
JP-4HD
JP-4HD
Cat5e
Cat5e
JP-4HD Cat5e
JP-4HD Cat5e
PS24
JP-4HD
Cat5e
Hands-free color video intercom sub master station
JP-4HD
Boxed sets
JP-4HD Cat5e
JPS-4AED: JP-4MED, JP-DA, PS-2420 JPS-4AEDV: JP-4MED, JP-DV, PS-2420 JPS-4AEDF: JP-4MED, JP-DVF, PS-2420
Lineup
Access Control m P.95
Jx-DVF-AC
AC-10S
JPW-BA
Long distance adaptor m P.6
Jx-DVF-AC + JP-DVF
JP-DV
GT-D
28.5
IER-2
100
132
135 RY-3DL
45
140 98
33
AC-10F
83.5
98
27
74 JP-8Z
45
117
Electric door strike m P.98
RY-3DL
Multiple door release adaptor m P.6
88
29
123
Video monitor Pixels Video output Night viewing
61
Wiring distance (m P.5)
24V DC PS-2420 Max. 340mA(JP-4MED). Max. 200mA (JP-4HD) Chime. Image & audio, approx. 45 or 90 sec. Automatic(Hands-free): approx. 1 min. To activate, touch TALK button. Handset: approx. 3 min. To activate, lift handset. 7-inch color LCD screen 1,150,000 pixels NTSC/PAL, 1Vp-p/75d Up to 50cm from camera, with white LED projected, background beyond 50cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: CAT5e Door to Master: 100m (1.0mma) Master to farthest sub: 300m(CAT5e)
309
5.6
5 45
Power source Power supply Consumption Calling Communication
Door release Option output Wiring
42
109
125 295
98
25
5.6
209
173 30.5
55
AC-10S
8
JP-DVF
130
97
120
48
68.5
145
129
JP-DA
255
JP-DVF-L
EL-12S
Specifications (JP-4MED,JP-4HD)
JP-4MED, JP-4HD
144
Distribution adaptor
JP-DV + AC-10S
Unit dimensions
Jx-DVF-AC
JP-8Z
INTERCOM SYSTEM
Access control keypad, surface mount
PS24
150
30
45
Also refer to P. 3-6 for details.
78
Open Voice Intercom DOOR
ROOM
1 LEM-1DL
1
Door station
Master station
Lineup
AC-10S
Access control keypad, surface mount m P.95
LE-DA
LE-D
Sub station m P.84
Sub station m P.84
LEM-1DL
Master station
AC-10F
Access control keypad, flush mount m P.95
EL-12S
Electric door strike m P.98
LE-DL
Power supply PS-1225
Sub station m P.84
m P.99
Features
Wiring
INTERCOM SYSTEM
l Single door open voice access control system l Adjustable tarnsmit (front) and tone volumes l AC/DC power supply
(1)
300m / 0.8mma
LE-D
LEM-1DL
2
Communication network
2
M LE-D
1 E –
LEM-1DL
1 E EL-12S 12V AC, 125mA
(
M
(2)
EL EL + –
)
LE-D
H
LEM-1DL 2
M
Unit dimensions LE-D
1 E –
LEM-1DL
2 1 E
EL-12S
EL EL 120
83.5
180
PWR
29
88
143
LE-DA
53.5
Specifications (LEM-1DL)
LE-DL
83.5
175
83.5
115
10 120
Power supply Communication
25.5
Wiring Wiring distance
79
H/T
(1) Using EL-12S door release (2) Using door release of other manufacture rated : 30V AC/DC, 1A max. Do not remove shorting link on LE-D. PWR : Power source
Power source
116
+ –
12~16V AC, 4VA 12~24V DC, 200mA (24V) AC transformer, PS-1225 When called by tone, press TALK to reply. Press door release button to release door, and press OFF for standby. 2 wires, non-polarized (+2 for EL-12S) LEM-1DL to door 200m(0.65mma) 300m(0.8mma)
Open Voice Intercom MASTER
SUB
3 LEM
1
Master station
Door station
Room sub station
LE-D
Sub station m P.84
LEM-1
1-call master
LE-A
Sub station m P.84
LEM-3
3-call master
LE-DA
Sub station m P.84
Power supply 6VDC2500/1 m P.99
LE-AN
Privacy sub m P.84
Features
Wiring 300m / 0.8mma
LEM-1 LEM-1
INTERCOM SYSTEM
l Open voice communication l Push-to-talk at master, hands free at remote l LE sub stations: either door station or room sub station l Voice volume control
LE-A 2
Communication network LEM-1 LEM-1
1 E
LE-A
1 E –
+ –
LEM-3
LEM-3
300m / 0.8mma
LE-D
300m / 0.8mma
LEM-3 2
LE-A
LEM-3
LE-D
W
LE-A 2x2
LE-AN 2
LE-AN 1
1 E –
LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from sub
E
Unit dimensions
2
1 E –
3
LEM-3
+ –
W
1 E –
★ Do not remove shorting link on subs.
180
160
LEM-1, LE-A, LE-AN
Specifications (LEM) 131
51
143
LE-D
115
83.5 29
116
Power source Power supply Communication
83.5
LE-DA
120 88
53.5
10
Output Wiring Wiring distance
6V DC 6VDC2500/1 Sub calls in w/tone and LED, 20 sec. Depress selector button and press or release TALK button. Sub called by tone or voice. Reply hands-free. 350mW output, adjustable 2 parallel wires per sub, non-polarized LEM to sub 200m(0.65mma) 300m(0.8mma)
80
Open Voice Intercom STATION
11 LEF Master station
Master station
LEF-3
3-call master
LEF-5
LEF-10
LEF-5W
LEF-10W
5-call master
LEF-3L
3-call master w/ door release button
5-call master w/terminal box
LEF-10S
10-call master
10-call master (all call)
10-call master w/terminal box
Power supply PS-1225 m P.99 Features
INTERCOM SYSTEM
l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA)
Wiring Door answering w/selective door release 300m / 0.8mma LE-D #2
LEF-5
E
LE-D
M M
LEF-5
EL-12S EL-12S
Selective call between inside stations. Answering & releasing door from any inside station
Cabling Models LEF-3 LEF-5 LEF-10 LEF-10S
Capacity 4 stations 6 stations 11 stations 11 stations
Cable 9 wires 11 wires (+5: K1~K5*) 17 wires (+10: K1~K10*) 20 wires (+10: K1~K10*)
l K1 ~K10: Control terminals for video, door release. l LEF-3 does not have L terminal. l Door & inside sub stations can ring 2 or 3 LEF masters. l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs)
81
3 1 C 3 4 5
1 2 C 4 5
1
2
3
–
E R Y + –
E R Y + –
L
L
Q Q
L
K4 K5
K4 K5
K4 K5
YL LEF-5
LEF-5 13
E R Y + –
E
–
LEF-5 13
C 2 3 4 5
1
1
LEF-5 4
RY-PA's
Communication network
LE-D
LE-D #1 3
BK
H
C : PS-1225 H : AC transformer Terminal 4 : for LE-D #1, Terminal 5 for LE-D #2. YL : Yellow(2) BK : Black(2).
T
Door station
Room sub station
Lineup
All call, music & chime
EL-12S
Electric door strike m P.98
BG-10C
LE-D
Sub station m P.84
Sub station m P.84
Door release relay m P.98
LEW-5
LEF-5 terminal box
All call, chime & music adaptor m P.84
LE-A
RY-PA
LEW-10
LEF-10 terminal box
LEW-10S
LEF-10S terminal box
LE-DA
AC-10S
Sub station m P.84
Access control keypad, surface mount m P.95
LE-AN
Privacy sub m P.84
Unit dimensions
BG-10C
LE-D
18
3
LEF-10S
LEF-10S LEF-10S LEF-10S 22 22 22
131 143
53.5
1
E
E
–
–
EL-12S
H
YL BK
C 2 3 4 5 6 7 8 9 10 1 E R Y + – L
1 C 3 4 5 6 7 8 9 10 2 E R Y + – L
1 2 C 4 5 6 7 8 9 10 3 E R Y + – L
1 2 3 C 5 6 7 8 9 10 4 E R Y + – L
Q Q
K9 K10
K9 K10
K9 K10
K9 K10
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3 + –
T
3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to wire multiple subs (2 common + 1 per sub). l LE-D call-in chimes on LEF stations. l Only LEF-10S station can transmit all call. l Match door release control terminals (Kn) with door selector #10 with K10, #9 with K9. ★ Remove a shorting link on LE subs. T : PS-1225 H : AC transformer Q : RY-PA
165
1 2 3 4 5 6 7 8 DB DA 11 E R Y + –
M
EL-12S
51
55
190 BG-10C
M
1
LE-A, AN
206
3
180
LE-D
LEF-5, 10, 10S
250
77
INTERCOM SYSTEM
LEF-3
Intermixed configuration
160
Wiring
AC-10F
Access control keypad, flush mount m P.95
Specifications (LEF) Power source Power supply Communication
Door release Selector switch Wiring
Wiring distance
12V DC, 300mA per LEF station. PS-1225 Sub calls in w/(chime) tone & LED, 20 sec. Depress the LED lit selector button. Use TALK/LISTEN switch. Master calls in w/tone or voice (no LED lit). Reply hands-free. To call, depress a selector, and call by voice or tone. Contact: 30V DC, 0.1A (resistance load). Contact: 12V DC, 30mA. 5 wires common + no .LEF (& subs) (all-master system) 2 wires per sub (single-master system). * E to - link remains attached. LE subs: 3 wires with the link removed (when intermixed) Farthest LEF’s 200m(0.65mma) 300m(0.8mma)
Specifications (BG-10C) Power source All call transmit All call receive Chime tone transmit Controls Wiring Wiring distance
12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma).
82
Open Voice Intercom DOOR
ROOM
8 LEF-C
3 Door station
Master station
Sub station
LE-D
Sub station m P.84
LEF-1C
LEF-3C
All call sub master
3-call master
LEF-5C
LEF-10C
5-call master
10-call master
Power supply PS-1225 m P.99
Features
INTERCOM SYSTEM
l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA)
Wiring LEF-10C✕7 (20)
1
LEF-10C
LEF-10C
LEF-10C
E –
LEF-10C
DA
EL-12S
Intermixed configuration Internal communication by Selective call. Sub calls in with tone & LED 20 sec.
9 10 11 E R Y + – P1 P2 P3 + –
Power source Power supply Communication
15.5
15 20
83
200
15.5
40
20
208
200
208
238
Output
153
1 C 2 3 4 5 6 7 8 9 10 1 E R Y + – L P1 P2 P3
1 C 2 3 4 5 6 7 8 9 10 2 E R Y + – L P1 P2 P3
1 2 3 C 4 5 6 7 8 9 10 3 E R Y + – L
1 2 3 4 C 5 6 7 8 9 10 4 E R Y + – L
1 2 3 4 C 5 6 7 8 9 10 5 E R Y + – L
1 2 3 4 5 6 C 7 8 9 10 6 E R Y + – L
1 2 3 4 5 6 C 7 8 9 10 7 E R Y + – L
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
153
Door release
15.5
15 20
1
1
E
E
1 E
–
–
–
T
DCIN
LEF-1C
LEF-5C LEF-10C
19
16
16
16
H : AC transformer
Specifications (LEF-C)
Unit dimensions LEF-3C
17
T : PS-1225 Q : RY-PA relay BK : Black(2) YL : Yellow(2)
LEF-10C
LEF-10C
–
BK YL Q
H LEF-10C
1 2 3 4 5 6 7
LE-D
Communication network LE-D
17
3 BG10C
Selector switch Wiring Wiring distance
12V DC, 300mA per station. PS-1225 Sub/door calls in w/tone & LED, 20 sec. Depress the LED lit selector button. Depress TALK/LISTEN switch. The LED stays lit while in use. Single talk channel w/OCCUPIED lit. 800mW at 20d (receive). 500mW at 20d (transmit). Contact: 110V AC, 1A. 24V DC, 1A. (on RY-PA output). Contact: 12V DC, 1A. (K terminals) 5 or 6 common + no. all stations Farthest LEF-C’s 200m(0.65mma) 300m(0.8mma)
LE Sub stations & Accessories Weather-resistant sub
Unit dimensions
Sub station
LE-DA
88
Sub station
29
116
83.5
175
115
120
LE-D
LE-DL
83.5
LE-DA
83.5
LE-D
10 25.5
120
LE-DL
Sub station LE-DA; 2-gang mounting
Room sub
Unit dimensions
160
LE-A, AN
131
LE-A
Sub station
51
LE-AN
Privacy sub
All call sub master 84
LE-SS/A
LE‑SS/A
Audio Door Station
153
120
LEF-1C
Specifications (BG-10C)
Unit dimensions
Power source 165
BG-10C
250
BG-10C
All call, chime & music adaptor
15
All call sub master
50
All call/music/chime adaptor
15.5 20
84
Audio Door Station
120
LE‑SS‑1G
LEF-1C 50
208
70
Unit dimensions
INTERCOM SYSTEM
114
LE-SS-1G
77
All call transmit All call receive Chime tone transmit Controls Wiring Wiring distance
12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma).
84
Hands-free Intercom MASTER
SUB
4 DB-1MD
1
Features • • • •
Total hands-free communication, auto-voice actuation Press-to-talk operation available Up to 5 stations All call for internal communication
Unit dimensions
Wiring 100m / 1.0mma
DB-1MD/1SD
DB-1MD
4 2
4 2
4
4 2
80
DB-1MD
Master station
Sub master station
PT : AC transformer
DB-1SD
DB-1SD
185
DB-1SD
DB-1SD
DB-1SD
DB-1SD
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
OUT B1 B2 B3 B4 IN B1 B2 B3 B4
IN B1 B2 B3 B4 OUT B1 B2 B3 B4
IN B1 B2 B3 B4
~ ~
~ ~
~ ~
~ ~
27 B1 B2 B3 B4
PT PT
DB-1SD
DB-1SD
D E ~ ~
16VAC1500/5 m P.99
16VAC1500/5 P : Polarized
16VAC1500/5
Specifications (DB-1MD, 1SD) Power source AC transformer Communication
16V AC 16VAC1500/5 Approx. 10 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button twice.
Handset Intercom MASTER
3 AT-406
INTERCOM SYSTEM
Master station
Sub station
16VAC1500/5 ~ DB-1MD 55m(0.65mma) 100m(0.8mma) 155m(1.0mma) DB-1MD ~ farthest DB-1SD 100m(0.65 ~ 1.0mma)
Features
SUB
1
Wiring distance
• • • •
Handset master-sub intercom w/2 additional subs (optional) Battery status LED Batteries or DC power supply Buzzer or bell activation (optional)
Boxed set
AT-406
Boxed set (white color)
AT-406B/A
Boxed set (charcoal gray)
Power supply
AT-306
Master station
6VCD2500/1 or Batteries m P.99
Sub station
Communication network AT-206 AT-306 x 3
Wiring
Unit dimensions AT-206 AT-306
AT-306
AT-206
210
1 2
Master calls all the subs simultaneously, while the sub rings the master only.
80
2
AT-306 2
83.5
2
AT-306
51
W
NP
+ ---
1 2
NP
1 2
NP
1 2
W : 6VDC2500/1
Specifications (AT-406) Power source Power supply Communication
85
6V DC 6VDC2500/1 or Batteries gAAh (SUM-3) x 4 pcs Press CALL button to ring all subs. Pick up any phone. Sub rings master only. Common talk.
Wiring Wiring distance
2 parallel wires. non-polarized 2-station set 700m(0.65mma) 1000m(0.8mma) AT-206 to subs 1~3 400m(0.65mma) 600m(0.8mma)
Handset Intercom STATION
90 YAZ-90-3W Phone extension
Lineup
YAW-RB
1-zone paging adaptor for YAZ-90-3W
Power supply PS-2420
YAZ-90-3W
Phone master station
m P.100
Features
Communication network YAZ-90-3W Paging Speaker
YAZ-90-3W
2900m / 0.8mma #10 4P YAZ-90-3W
#39
#40
3P
4P
YAZ-90-3W YAZ-90-3W
YAW-RB
1 2
1 2
1 2
1 2
3 4
3 4
3 4
3 4
5 6 + –
5 6 + –
5 6 + –
5 6 + –
N
N
M G A
Paging amp. IN
White
TB P G
OUT
Paging speaker line
shielded Power relay
White
AC
Paging speakers
Power supply (for relay)
l Remove +,- wires between YAZ stations of different blocks. Within a block locate a power supply in the center of cable run, and make groups of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to each group's initial YAZ station. N : PS-2420
YAZ-90-3W YAZ-90-3W
Specifications (YAZ-90-3W) Power source Power supply Communication
Station to station communication in any pair
Unit dimensions
Line loop resistance Wiring Total wiring distance
YAW-RB
YAZ-90-3W
Wiring
INTERCOM SYSTEM
l Microprocessor built-in intercom expandable to max. 90 stations on 4-pair cable l Up to 2.9km wiring distance l Zone paging l Communication functions: Camp-on busy, secretary transfer, call transfer l Line-off trouble on one channnel does not affect the other channels
24V DC, 150mA max. 20mA standby. PS-2420 per 30-station block. Dial 2-digit station # to ring other station with tone or voice pressing PAGE. Privacy communication on each channel (max. 3). Must not exceed 200d for farthest stations. 20d for power line. 4-twisted pairs (shielded) in loop. Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma)
158
83.5
230
Specifications (YAW-RB)
152
94
84
Power source Consumption Paging impedance/level 59
Music impedance/level Line resistance Amp. power ctrl. contact
YAW-RB: 24V DC, 150mA (paging).40mA (standby). YAW-RB = 5 YAZ’s, powered by YAZ network. Input: 600d/78mV(RMS), 1KHz. Output: 600d/300mV(RMS), 1KHz. Input: 20Kd/300mV(RMS), 1KHz. Output: 600d/150mV(RMS), 1KHz. 20d loop for power supply line. 200d loop for intercom line. YAW-RB: 240V AC 10A. 24V DC, 10A.
86
Handset Intercom STATION
25 TD-H/B Door station
Sub station
Master station
TD-1H/B
TD-3H/B
IF-DA
Door station m P.74
DE-UR
Door station adaptor
Power supply PS-1225 m P.99
1-call sub
TD-6H/B
3-call master
6-call master
Wiring
Features
INTERCOM SYSTEM
l All-master selective ring system l Single-master configuration or intermix w/TD-1H/B l Multi-conductor cable in loop l Multi-talk channels l Door station(s), audio or PanTilt video (max. 2) l Zone paging, with or without talkback l Music source connection. Page pretone cuts out music.
(2) Door station communication 230m / 0.8mma
1000m / 0.8mma
IF-DA
DE-UR 1
1 2
1 2
1 2
C
2
TD-6H/B #1 10
#2
C 2 3 4 5 6
1 C 3 4 5 6
1 2 C 4 5 6
1 2 3 C 5 6
1 2 3 4 5 6
1
2
3
4
C
#4 10
#5 10
Communication network
TD-12H/B
TD-12H/B
TD-12H/B
Paging Speaker
TD-12H/B
TD-12H/B
TD-12H/B
IF-DA
All-master configuration. Station selector & CALL to ring any other station.
Wiring
(1) All-master configuration
TD-12H/B TD-12H/B
#1
#2 16
1 2 C
D
D
D
D
D
D
D
+ –
+ –
+ –
+ –
+ –
+ –
+ –
A
B
T
1000m / 0.8mma
#3 16
#11
#12 16
16
15m / 0.8mma
#13 16
(3) Single-master configuration TD-3H/B
C 2 3 4 5 6 7 8 9 10 11 12 1 D + –
87
#3 10
1 C 3 4 5 6 7 8 9 10 11 12 2 D + –
1 2 C 4 5 6 7 8 9 10 11 12 3 D + –
T
1 2 3 4 5 6 7 8 9 10 C 12 11 D + –
1 2 3 4 5 6 7 8 9 10 11 C 12 D + –
1 2 3 4 5 6 7 8 9 10 11 12 C D + –
l Install main cable of max. condctors allowed for each TD-H/B station model. C Terminal D : Door station
TD-1H/B 6
C 1 2 3
TD-1H/B 5
1 C
TD-1H/B 4
1 C
1 C
D
T
+ –
+ –
+ –
+ –
Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power supply.
Lineup
PD-1
Zone page adaptor
For desk-top or surface wall mounting, provide TDW-n/A terminal box w/1.5m cord.
PD-2
Zone page/talkback adaptor
TDW-1/A
TD-1H/B terminal box
TDW-3/A
TD-3H/B terminal box
TDW-6/A
TD-6H/B terminal box
TDW-12/A
TD-12H/B
TD-24H/B
12-call master
TD-12H/B terminal box
Power supply PS-1225
TD-24H/B terminal box
m P.99
TDW-24/A
24-call master
Wiring
External signaling relay m P.98
Specifications (TD-H/B) PD-1 (1)
TD-12H/B
3
(1)
T
Wiring
A G M
No.
C
DC12V
+ ---
+ ---
TD-H/B
+ ---
Wiring distance
T (PD-1,PD-2)
(5) Paging with talkback w/PD-2 (single zone) (2)
PD-2 TD-12H/B
Power source Output Paging & music tone controls Amp. input Music input Tuner output Tape output Talkback gain Environmental noise Paging
(1)
3
T (1)
S S V V A G M
(2)
No.
C
DC12V
+ ---
+ ---
+ ---
TD-H/B
T (1) Paging Speakers (2) Talkback speakers
T : PS-1225
Wiring
Unit dimensions
210
210 73
83.5
91 100
AUX or PHONO 100K-500Kd, 0.12~0.5V 17Kd, 0.3V, 1KHz. for full output Audio output: Range 100mV~1.2V, 10Kd or less Low level output: Range 100mV~1.2V, 600d 40dB, 1KHz. at max. volume Less than 80dB (phon) Select an assigned selector # and page w/PAGE button depressed. Release to receive reply 3 wires to TD-H/B via power supply
PD-1 PD-2
TD-24H/B
83.5
PD-1: 12V DC, 300mA. PD-2: 12V DC, 48mA (talkback). 5Kd . Max. 1.5V Treble 12dB at 10KHz. Bass 12dB at 100Hz.
138
TD-1H/B ~ TD-12H/B
12V DC, 70mA per station. PS-1225 Depress a station selector 1~12 and CALL (or CALL A) to ring station 1~12 (or A1 ~ A12). Lift handset to reply. Door calls in w/standard or faster(B) intermittent tone, 2-1/2 sec. Pick up and depress the selector assigned. 2 or 3 + no. TD-H/B in loop. TD-1H/B: 4 wires. TD-3H/B: 7 wires. TD-6H/B: 10 wires. TD-12H/B: 16 wires. TD-24H/B: 28 wires. TD-H/B stations 650m(0.65mma) 1000m(0.8mma) DE-UR to door 150m(0.65mma) 230m(0.8mma)
INTERCOM SYSTEM
Power source Power supply Communication
(4) Straight paging w/PD-1 (single-zone)
100
RY-AC/A
51.5
83
88
Security Window Intercom SERVICE SIDE
1
PUBLIC SIDE
1 IMU-100
Service Side
IMU-100 Main kit
IMU-100 IME-100 Operation unit
IME-100
Gooseneck microphone
Main unit
Power supply PS-2420
m P.100
Features
INTERCOM SYSTEM
l First in industry! Using an acoustic tube with noise cancelling microphone l Voice-actuated hands-free communication l Flexible gooseneck type microphone l Optional Mono type headset (a3.5 plug) l Detection sensor switches automatically to communication mode l Separate speaker system using an optional microphone l Paging feature for announcements l Thin shape of the acoustic tube does not obstruct the field of vision l Holes in the barrier glass are not necessary to install
Communication network Acoustic tube system 3
Paging speaker
ISE-100
2
Barrier glass
IAI-100 + IAX-100
1
IMU-100 + IME-100 Service Side 1 2 3
Public Side
Voice-actuated hands-free communication Automatically switch to communication mode Paging
Separate speaker system 3
2
External speaker
Paging speaker
ISE-100
+ Barrier glass
IME-150 3
IMU-100 + IME-100 Service Side
89
Public Side
Lineup
Public Side
Acoustic tube system
Separate speaker system IAI-100
Acoustic interface kit
ISE-100 Sensor
External Speaker (locally available) IAI-100 IAX-100
Driver unit
+ Paging speaker (locally available)
IAX-100
Acoustic tube
Acoustic I/O tube
IME-150
Optional microphone
Unit dimensions
Wiring
Supplied cable
IMU-100 + IME-100
Cord (3.5m)
IME-150
160
27
ISE-100
Paging speaker
130
40
210 49
Cord (3.5m) Shielded cable 2
370
2 Shielded cable
External speaker +
24
388
2
2
2
206
Mic.
Acoustic I/O tube
Operation unit
45
Speaker
Main unit
Separate speaker system
IME-100 63
420
14.5
510
2
34
INTERCOM SYSTEM
20m / (1.2mma)
3800
40
IAX-100 24
N
1000
W1 E – +
ST-BY SW
– SW +
PG OUT
C H
DC24V
+ –
WHITE(C) BLACK(H)
150
72
3500 68
Shielded(E) WHITE(-) RED(+)
Shielded WHITE RED
Connection cord (approx. 3.5m) Shielded WHITE RED
Connection cord (approx. 3.5m) W3
Specifications (IMU-100) Power source Power supply Consumption Operating temperature Communication Headset
N
External speaker Paging speaker
N : PS-2420
36
30
C H
105
W2
115
Connector
Driver unit 84
23
ISE-100 3500 60
Separate speaker system
13
IME-150
Supplied cable (approx. 2m)
27
24V DC PS-2420 120 mA (standby) 780 mA (maximum) 0kC to 40kC Voice-actuated communication Transmit output: 3 W 4 d, Receive output: 1.5 W 16 d a3.5 plug, Impedance: 32 d, Rated input: 40 mW or more, Maximum input: 100 mW or more Impedance: 4 to 8 d, Rated input: 3 W or more Maximum input: 6 W or more Impedance: 4 to 8 d, Rated input: 3 W or more Maximum input: 6 W or more
90
Master / Sub Intercom MASTER
SUB
100 TC-M
2
Master station
TC-20M
20-call master
TC-10M
10-call master
TC-20M + TC-40G 60-call
Features
INTERCOM SYSTEM
l Expandable internal telephone intercom l One or dual master configuration l Tone & LED call-in, staying on until answered l Additional buzzer at TB-SE (w/relay) l TRANSFER button on TC-M for communication between two TB-SE subs
Wiring
TC-10M TC-20M
Communication network
TC-20G TC-40G
TB-SE TC-20M
The TC-40GS is equipped with socket to connect the second add-on selector TC-20G or TC-40G.
Specifications (TC-M)
TB-SE
Power source *TB-SE
Consumption Power supply Communication
TC-20M
*TB-SE : Sub station for two-master call.
Wiring Wiring distance
Unit dimensions TB-SE
480 405 330 255
210
230
210
83.5
115
80 555 630
91
TC-40GS
72
18V DC, 350mA. 15~16V AC, 50/60Hz, 750mA. 6W. 3W standby. PS-1820 AC transformer. Pick up TB-SE handset. Rings TC-M, w/tremolo & LED, staying. At TC-M, pick up and press a lit selector to reply. 2 parallel wires per TB-SE, non-polarized. TC-M’s 200m(0.65mma) 480m(1.0mma) TC-M~TB-SE 400m(0.65mma) 900m(1.0mma)
Add-on selector
Lineup
Sub station
IER-2
Call extension m P.98
TC-20G
20-call add-on selector
TB-SE
Sub station
TC-40G
Power supply PS-1820
40-call add-on selector
TC-40GS
m P.99
W/add’l 20-/40-call expansion
Wiring 2
Wiring 1 480m / 1.0mma
TC-M
2
2
2 TB-SE 2 2 2 2
1 2 1 2 1 2 1 2 1 2 1 2 1 2
1 2 3 4 5 6 7 8 9
2
10
TB-AD1
E
E
3 TB-SE 2
E E E E
E
E
E
E
E
E M C
E
E M C
1 2
E
9.TB-SE
1 E
E
E
S
IER-2
E
E
+ - 12V T S R S
2 IF-DA
E
E
TB-SE
TC-M
U U
E
900m / 1.0mma
1 2 3 4 5 6 7 8
1 TB-SE 2 1 2 1 2 1 2 1 2 1 2 1 2
2
1 2
1 2
2
19 20 + – T R
N + – T R
TB-AD1 5 (x3)
TB-AD1
TB-AD1
2
2
2
2 TC-20M
10
+ 12V T S R
5
2
2
9
TC-20M
TB-AD1 2
2
INTERCOM SYSTEM
900m / 1.0mma
TB-SE
IF-DA
IF-DA
IF-DA
TB-AD1
1 E
IER-2
l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s. l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system).
92
Master / Sub Intercom DOOR
ROOM
1 TC-M & TB-AD10
10 Door station
Master station
Door adaptor
Lineup
IER-2
Call extension m P.98
TB-AD1
IF-DA
1-call door adaptor
Door station m P.74
TC-10M
10-call master
TB-AD10
10-call door adaptor
Power supply PS-1820
EL-12S
Electric door strike m P.98
m P.99
Features
Wiring
INTERCOM SYSTEM
l Single or multiple audio door communication, expandable l Optional selective door release control
IF-DA
TB-AD10 2 (x10)
Communication network
2
NP
11
EL-12S
PT
IF-DA TC-M+TB-AD10
1.
1 2
D1
1 2
D2
1 2
D3
1 2
D4
1 2
D10
2. 10. EL-12S ( 10)
M
Pre-tone sounding or mute selectable at TB-AD10.
Unit dimensions TB-AD1
TB-AD10
E
E E
E
D1 D2 D3 D4
10
10
D10 DE
D10 DE
12V
12V
T R
T R
TB-AD10 2
L2 L2 L3 L3
L10 L10
EL-12S
TC-20M + TC-20G
TB-AD10 1
97
T
TC-20M
TB-AD1
L1 L1
L4 L4
U
230
140
83.5
150
Wiring 2
D1 D2 D3 D4
PRE-TONE ON OFF
TB-AD10 3
42
IF-DA
1 2 3 4
E
IF-DA
74
1 2 3 4
2 IF-DA 10
5
2
2 IF-DA 10
IF-DA 10
Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after.
1 2
1 2
N + – T R
2
U : PS-1820
Specifications (TB-AD10) U
TB-AD1 5 (x3)
TB-AD1
TB-AD1
2
19 20 + – T R
2
Wiring TC-20M
IF-DA
93
IF-DA
Power source Door capacity Communication
IF-DA
Wiring distance
TB-AD10: 12V DC, supplied by TC-M. 10(TB-AD10). 1(TB-AD1). Door calls in w/tremolo & LED 40 sec. Pick up and depress LED lit selector. Pretone sounds at door, or silenced. 2 parallel wires to door, non-polarized. 4 common + no. doors, TC-M to adaptor. TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma) TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma)
Market-Com STATION
60 MC-60/4A Market-com station
Market-com adaptor
Lineup Paging speaker
w/built-in transformer (locally available)
MC-A/A
Zone page adaptor
Power supply PS-2420
MC-60/4A
Market-Com station
m P.100
Features
Wiring S
MC-60/4A 10 3 #1
2
1
1
7
7
7
7
7
7
7
7
2
3
MC-60/4A 10
7
7
7
7
7
7
7
7
#2
MC
Communication network #3
#4 MC-A/A A G M
(1) MC-60/4A
MC-60/4A (2) Ch.1 Ch.4
(1) Paging (2) Select a channel 1~4 paged, and communicate.
Unit dimensions MC-60/4A
#1- 10
3
2
1
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1/+ 2 3 4 5/– 6 7
N
MC-A/A
1
2
3
10 -#2
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
INTERCOM SYSTEM
l Max. 60-station paging & communication system l Selective 4 talk channels with in-use LED’s l Conference call among 3 stations l Music cutout during paging l Reinforced modular coil cord
#3~#6
143
83.5
234
Station blocks #1~6 of max. ten MC-60/4A’s N : PS-2420
91 90
Specifications (MC-60/4A) 51.5
94
Specifications (MC-A/A) Power source Amp. input Music soursce output
24V DC, PS-2420 AUX 10Kd, 0.3V~0.5V Range 100mV~1.2V, 10Kd or less
Power source Power supply Communication
Talk channel Wiring Cable specified Wiring distance
24V DC, 70mA max. (in page). PS-2420 at MC-A/A. Pick up and depress channel selector 1~4 and page w/PAGE button. Called party picks up and presses lit LED channel button. 4 and a separate paging channel. 7 wires in loop, non-twisted. Line capacitance less than 25pF/30cm. MC-A/A to MC-60/4A(*) 500m(0.65mma) 750m(0.8mma) Total wiring distance 1500m(0.65mma, 0.8mma)
(*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of different blocks.
94
Accessories Access control Surface mount
AC-10S Vandal resistant access control keypad, surface mount
Features
l Two types of keypads are available. AC-10S: Surface mount type AC-10F: Flush mount type l AC-10S matches JK-DV, JO-DV and JP-DV, color video door stations. l Vandal resistant panel, zinc die cast, and tamper proof screws are included. l Two independent relay outputs (N/O or N/C) are available. When same access code is programmed for both #1 and #2, two relays activate simultaneously. l Programmable up to 100 access codes* 4, 5, or 6 digits in length. * #1: up to 60, #2: up to 40 l Keypad lockout: After too many incorrect access codes are attempted. l Anti-tailgate: As soon as the door is closed after access is granted on #1, the door is locked even before programmed output time. Prevent sneak in. l One push door release with external timer connection: While the external timer is on operation, access code is not required. Press “0” key only. Programmable #1 and/or #2. l External output for alarming: When “Lockout” or “Forced entry” occurs, external output is available at #2. l Two LED indicators show the status of the access control system. l Illuminated keypad is easy to read. l Audible key press
Features l Activate door release (relay) By keypad
By request to exit/entry button
Enter ID #1
1 4 7 A
2 5 8 0
#1
#1
3 6 9 B
1 4 7 A
#2
Green
#2
2 5 8 0
3 6 9 B
#2
#1 #2
Beep
JK-DV, AC-10S m P.10
Press button
Orange
l Keypad lockout Bleep
Flush mount
The keypad is locked out after too many incorrect access codes are attempted.
1 4 7 A
2 5 8 0
3 6 9 B
Programmable l Incorrect access code: 10-99 times l Lockout time: 10-99 seconds Blink keypad 4 times Blink LED (orange) programmed period Sound buzzer approx. 3 seconds
l Anti-tailgate Door sense switch
ACCESSORIES
Enter ID for #1 Lock
1 2 3 4 5 6 7 8 9 A 0 B
AC-10F
Vandal resistant access control keypad, flush mount
l One push door release with external timer connection During the timer is on operation ON: 9AM-5PM
Power source 12-24V DC power supply 12-24V AC transformer ★
95
Press “O” key 1 4 7 A
2 5 8 0
3 6 9 B
The design and specifications are subject to change without notice for improvement.
Unlock
Door is locked 1 second after door was closed even during relay on-time.
Wiring (1) Relay #1 (Normally open)
(2) Relay #1 (Normally closed) & Relay #2 (Normally open) 300m /1.0mmø #1 Electromagnetic door strike
300m / 1.0mmø 2
MH2
2
12V-24V AC/DC
V V
SW #1
PB1 PB2 C T
Common #1 Electric door strike
NO1 C1 NC1
M
H
Request to exit switch #1
NO2 C2 NC2
2
Power source
V V
SW #1 SW #2 Common Timer
PB1 PB2 C T
#1 Electromagnetic door strike
Nomally closed
M
NO1 C1 NC1
2 12V-24V AC/DC
300m (18V - 24 AC/DC, 0.65 - 1.0mmø)
12V-24V AC/DC
Relay #1 N/O
2 2
door strike
300m (18V - 24 AC/DC, 0.65 - 1.0mmø) Power source
AC-10S
M MH2 #2 Electric
AC-10S
#1 Electric door strike
2
Relay #1 N/C
C
M #2 Electric door strike
H
NO1 C1 NC1 NO2 C2 NC2
12V-24V AC/DC Request to exit switch #1 Request to exit switch #2 Timer
Relay #1 N/C Relay #2 N/O
H : AC transformer C : Power supply
Unit dimensions
Specifications (AC-10S, AC-10F) 25
33
29.5
117
5
45
Access code
Number: Up to 100 (#1: 60, #2: 40) Code length: From 4, 5, or 6, (0 ~9, A, B) Two conductors Access control ~ Power source: 100m (12V – less than 18V AC/DC, 0.65 – 1.0 mmø) 300m (18V – 24V AC/DC, 0.65 – 1.0 mmø) Access control ~ Request to exit button 300m (0.65 – 1.0 mmø)
Wiring Wiring distance
Back Box
173
100
JK-DV + AC-10S
12 – 24V AC or 12 – 24V DC Max. 100mA Output: 2 Contact rating: 24V AC/DC, 3A (resistive load), 1A (inductive load) Dry contact: Normally open or Normally closed Operating time: From 1 second to 99 seconds
100
125
98
132
AC-10F
55 68.5
AC-10S
Power source Consumption Relay
45
Environment
Weather resistant (IP54 equivalent)
5
85
125
ACCESSORIES
98
33
Desk Stand
Features MCW‑S/A
Desk Stand for AX‑8M, AX‑8MV, AX‑8MV‑W, DB‑1MD, DB‑1SD, GT‑2C, GT‑2H, GT‑1C, GT‑1A, JF‑2MED, JF‑2HD, JK‑1HD, JK‑1MED, JP‑4MED, JP‑4HD, JO‑1MD, JO‑1FD, KB‑3MRD, or KB‑3HRD
• Allows desk mounting of master and / or handset station • Station is propped up for easier viewing • Pre‑drilled mounting holes • Made of ABS plastic • Adjustable to 45° or 60° angles
Used with:
AX‑8M, AX‑8MV, AX‑8MV‑W, DB‑1MD, DB‑1SD, GT‑2C, GT‑2H, GT‑1C, GT‑1A, JF‑2MED, JF‑2HD, JK‑1HD, JK‑1MED, JO‑1FD, JO‑1MD, JP‑4HD, JP‑4MED, KB‑3MRD, or KB‑3HRD
96
Accessories Angle Boxes
SBX‑DV30
KAW‑D
30˚ Angle Box for IX‑BA, IX‑DA, JF‑DA, JK‑DA, JO‑DA, JP‑DA, KB‑DAR, or KB‑DAR‑M
30˚ Angle Box for JK‑DV, JF‑DV, JO-DV, or JP‑DV
SBX‑AXDVF
Surface Mount Box for JF‑DVF, JK‑DVF, JO‑DVF, or JP‑DVF
ACCESSORIES
SBX‑ISDVF
Surface Mount Box for IS‑DVF, IS‑IPDVF, IS‑SS, IX‑DF, IX-DF-P, IX-DF-PI or IX‑SS
SBX‑1G
Surface Mount Box for LE‑SS‑1G
97
Surface Mount Box for AX‑DVF
SBX‑ISDVFP
Surface Mount Box for IS‑DVF‑HID, IS‑DVF‑RP10, IS-IP4DVF, IS‑IPDVF-HID, or IS‑IPDVF‑RP10
SBX‑2G
Surface Mount Box for IS‑SS‑2G, IS‑SSR‑2G, IE‑JA, IE‑SS/A, IE‑SSR, LE‑DA, LE‑SS/A or LE‑SSR
Specifications
Used with:
Material
KAW‑D: ABS plastic SBX‑DV30, 18AWG stainless steel Mounting Surface mount directly to wall or 1‑gang box
KAW‑D – IX‑BA, IX‑DA, JF‑DA, JK‑DA, JO‑DA, JP‑DA, KB‑DAR, or KB‑DAR‑M SBX‑DV30 – JF‑DV, JK‑DV, JO-DV, or JP‑DV
Specifications
Used with:
• Provides a better viewing angle for the camera • Designed for angle mounting door stations outward by 30° • Applicable for wide or double door entrances
Surface Mount Boxes
SBX‑DVF
Features (KAW‑D) • Provides a better viewing angle for the camera • Compatible with Aiphone 1‑gang surface mount door stations • Angles 1‑gang door stations outward by 30° • Can mount to either right or left of door • Hinged cover for mounting door station Features (SBX‑DV30)
Features (SBX‑DVF, SBX‑AXDVF, SBX‑DVF-P, SBX‑ISDVF, SBX-ISDVFP, SBX‑ISDVFRA)
SBX‑DVF‑P
Surface Mount Box for AX‑DVF‑P, JF‑DVF‑HID, JK‑DVF‑AC, or JK‑DVF‑HID
SBX‑ISDVFRA Surface Mount Box for IS‑SS‑CI, IS‑DVF‑2RA, IS‑SS‑2RA, IS‑SS‑2RA‑R, IS‑SS‑RA, IS‑SS‑RA‑R, IX‑DF‑2RA, IX‑SS‑2RA, IX‑SS‑RA, JP‑DVF‑HID, or JP‑DVF‑RP10
• Hood provides weather resistance • Includes space inside for wiring • Mounts directly to wall • Openings at bottom allow for moisture drainage Features (SBX‑1G) • Weather resistant • Includes space inside for wiring • Mounts directly to wall surface Features (SBX‑2G) • Weather resistant • Includes space inside for wiring • Mounts to 1‑gang box or ring • Can mount directly to wall surface • Includes hardware for mounting intercom
Material
SBX‑DVF‑P, SBX‑ISDVF, SBX‑ISDVFP, SBX‑ISDVFRA, SBX‑1G, SBX‑2G: 18AWG stainless steel SBX‑DVF, SBX‑AXDVF: 16AWG stainless steel (outer layer) 18AWG stainless steel (inner layer)
Mounting SBX‑DVF, SBX‑AXDVF, SBXDVF-P, SBX-ISDVF SBX-ISDVFP, SBXISDVFRA: surface mount directly to wall, 1-gang box, or 2-gang box with included hardware (8 x 32 with T‑15 Torx head) SBX‑1G, SBX‑2G: surface mount directly to wall or 1-gang box with included hardware (8 x 32 with T‑15 Torx head)
SBX‑DVF – JF‑DVF, JK‑DVF, JO‑DVF, or JP‑DVF SBX‑AXDVF – AX‑DVF SBX‑DVF‑P – AX‑DVF‑P, JF‑DVF‑HID, or JK‑DVF‑HID SBX‑ISDVF – IS‑DVF, IS‑IPDVF, IS‑SS, IX‑DF, IX‑DF‑HID, IX‑DF‑RP10, or IX‑SS SBX‑ISDVFP – IS‑DVF‑HID, IS‑DVF‑RP10, IS‑IP4DVF, IS‑IPDVF‑HID, or IS‑IPDVF‑RP10 SBX‑ISDVFRA – IS‑SS‑CI, IS‑DVF‑2RA, IS‑SS‑2RA, IS‑SS‑2RA‑R, IS‑SS‑RA, IS‑SS‑RA‑R, IX‑DF‑2RA, IX-SS-2RA, IX-SS-RA, JP‑DVF‑HID, or JP‑DVF‑RP10, SBX‑1G – LE‑SS‑1G SBX‑2G – IS‑SS‑2G, IS‑SSR‑2G, IE‑JA, IE‑SS/A, IE‑SSR, LE‑DA, LE‑SS/A, LE‑SSR, or NI‑JA
Accessories Call extension
Features
Wiring
l Announces (chime) call tone only, adjustable l Indoor mounting
JP-4MED
IER-2
Used for
2
IE series, TC-M JP-4MED, JO-1MD, JO-1FD, JK-1MED, DB-1MD
NP
S S
Unit dimensions
1 E
IER-2
29
88
Door release
83.5
120
Call extension
Features
Wiring
l Door release activation, momentary or talk linecontrolled
LEF-10C
JO-1MD
Used for
EL-12S
Electric door strike
DA-1DS, C-123L/A DA-2DS, DA-4DS/G IE-1AD(U), IE-1GD(U) IE-2AD(U), IE-8MD(2) TD-H/B (via DE-UR) LEM-1DL LEF, LEF-C (via RY-PA) JP-4MED, JO-1MD JK-1MED
EL-12S
EL-12S
YL
L L
BK
RY-PA
H
– L
H
BK : Black(2) YL : Yellow(2)
Specifications (EL-12S) Power source & Consumption 12V AC, 125mA 12V DC, 200mA
RY-PA
Specifications (RY-PA)
Door release relay
Relay
Power source Relay contact rating
Features
Used for
TD-H/B IE-Series IE-8MD, LEF
Wiring LEF-10
LE-D
(1) (2)
PWR
1 E
1 E
–
+ –
T
WH YL RD RY-AC/A BK YL
(1) External signaling device, bell, etc. (2) Call receive termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow PWR : Power source
Unit dimensions RY-AC/A
ACCESSORIES
Intercom station can be signaled by external device via RY-AC/A relay. External device will be activated momentarily as long as the call signal on the intercom is activated.
12V DC 110V AC, 1A 24V DC, 1A
Specifications (RY-AC/A)
External signaling relay 62
Power source
104
41
Contact rating
12V DC, supplied by power supply of system or trunk line. 0.3A, 240V AC 1.0A, 24V DC Bell, buzzer, etc. must be AC operated or DC mechanical type only.
98
Power Supplies 16V AC
Used for
Specifications (16VAC1500/5)
DA-1MD, DB-1MD
6V DC
Output voltage
16V AC, 1.5A
Input voltage & Capacity
230-240V 50Hz
Output voltage
6V DC, 0.2A
Specifications (PS-1225)
Unit dimensions PS-1225 90
240V AC, 50Hz
Specifications (6VDC2500/1)
Used for
C-123L/A, AT-406, LEM,
12V DC
Input voltage & Capacity
Input voltage & Capacity
100-240V AC, 50/60Hz 37W/6582VA
Output voltage
12V DC, 2.5A
167
52
Used for PS-1225
18V DC
IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2DU, IE-8MD, LEM-1DL, LEF, LEF-C, TD-H/B, (TC-M)
Unit dimensions PS-1820S 90
52
167
ACCESSORIES
99
PS-1820
Used for
IE-8MD, JBW-BA, JO-1MD, JO-1FD, JK-1MED TC-M, RY-3DL
Specifications (PS-1820) Input voltage & Capacity
100V-240V AC, 50/60Hz, 45W/75-95VA
Output voltage
18V DC, 2A
24V DC Unit dimensions
Used for
YAZ-90-3W, JP-4MED, JP-4HD, JPW-BA, JP-8Z, RY-3DL, MU-100
PS-2420 52
Specifications (PS-2420)
167
90
Input voltage & Capacity
100-240V AC, 50/60Hz 60W/100-125VA
Output voltage
24V DC, 2A
PS-2420
AIPHONE Approved product wire AIPHONE Wire model name Model AE7090220B AE7090220G AE7090210B AE7090210G AE7120230B
AE7090220B AE7090220G AE7090210B AE7090210G AE7120230B
Length 200m 200m 100m 100m 300m
Gauge a0.9mm a0.9mm a0.9mm a0.9mm a1.2mm
Insulation PE PE PE PE PE
Jacket color BEIGE GRAY BEIGE GRAY BEIGE
Description 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded 2 conductor, PE, solid, non-shielded
Recommendation GT GT JK, JO, GT JK, JO, GT JKW-BA, JPW-BA
Wire number coding 1st & 2nd Characters 3rd digit 4th & 5th digits 6th & 7th digits 8th & 9th digits 10th Character
: Wire Approval : Type of Wire : Gauge : Number of Conductors : Length of Wire : Color of Jacket
AE=Aiphone approved wire 7=solid, PE, non-shielded 09=0.9mm diameter, 12=1.2mm diameter 02=2 conductors 10=100 meters box, 20=200 meters box, 30=300 meters box G=Gray, B=Beige
Cable printing Printing AIPHONE P/N AE7090220B 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7090220G 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE
AE7090210B AE7090210G AE7120230B
AIPHONE P/N AE7090210B 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7090210G 0.9-2C MADE IN JAPAN YYYY ROHS AIPHONE AIPHONE P/N AE7120230B 1.2-2C MADE IN JAPAN YYYY ROHS AIPHONE YYYY: Year of Production
: Lead free vinyl
USING AIPHONE WIRE EXTENDS YOUR AIPHONE VIDEO PRODUCT WARRANTY BY ONE YEAR.
ACCESSORIES
Model AE7090220B AE7090220G
100
Communication Distance The below graph is to assist you in determining the diameter of wires or communication distance required. Example; To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires; 1. On the graph; Draw a line from IE-1AD(U) on point A 7.8, crossing the line B at the point 0.8 to reach a point reading 225.
A
Distance
B
IE-1AD(U) 0.8 28 225 (m)
COMMUNICATION DISTANCE CALCULATION GRAPH SYSTEM & MODELS TB-AD1, AD10 [TC-M] C-123L/A IE-1GD(U) [IEH-1CD] IE-2AD(U) [IEH-1CD] IE-2A2DU [IEH-1C2D]
A
COMMUNICATION DISTANCE ...m
FIXED NUMBER FOR DISTANCE BY ITEM
2,000
3.4 3.9
B IE-1AD(U) [IF-DA] IE-1GD(U) [IF-DA] IE-2AD(U) [IF-DA], IE-2A2DU DE-UR [IF-DA]
7.8
DIAMETER mm 1.6 1.4
1,000 900 800 700 600
10.4
500 0.8
LEM-1, LEM-3 LEF-3, LEF-5 , LEF-10 LEF-10S LEF-3C, LEF-5C, LEF-10C
400 0.65 20.9 26.2
300 0.5 225 200
34.0 36.7 AT-206 [AT-306x3] TC-M [TB-SE] 100
MC-60/4A
90 80
TD-1H, TD-3H, TD-6H TD-12H, TD-24H
70 60
AT-406
50 40
30
20
NOTES; IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station. Video Intercoms are not included in the graph.
101
Compatibility of video intercom system Color video intercom ✓: Compatible Blank: Not Compatible Existing model Door station Sub station
Master station
JP-DA JP-DV JP-DVF JP-DVF-L
JO-1MD JP-4MED
Audio door station
Video door station JO-DA JO-DV JO-DVF
JK-DA JK-DV JK-DVF
AX-DV AX-DV-P AX-DVF AX-DVF-P
GT-D
✓
✓
AX-8MV
JO-1FD
JP-4HD
JK-1HD
JK-1SD (audio)
JPW-BA
JKW-BA
✓
✓
JK-1MED
Long distance adaptor
Sub master station
✓
✓ ✓
✓
✓
✓
✓
AX-8MV requires a central exchange unit.
102
INDEX APAGE AC-10F�������������������������������������������������� 95 AC-10S�������������������������������������������������� 95 AE7090210B��������������������������������������� 100 AE7090210G��������������������������������������� 100 AE7090220B��������������������������������������� 100 AE7090220G��������������������������������������� 100 AE7120230B��������������������������������������� 100 AT-306�������������������������������������������������� 85 AT-406�������������������������������������������������� 85 AT-406B/A��������������������������������������������� 85 AX-084C������������������������������������������� 15,59 AX-16SW������������������������������������������ 16,59 AX-248C������������������������������������������� 15,59 AX-320C������������������������������������������� 15,59 AX-8M���������������������������������������������� 16,59 AX-8MV�������������������������������������������� 16,59 AX-8MV-W��������������������������������������� 16,59 AX-DM���������������������������������������� 15,60,74 AX-DV���������������������������������������������� 15,59 AX-DVF��������������������������������������������� 15,59 AX-DVF-P����������������������������������������� 15,59 AX-DV-P������������������������������������������� 15,59 BPAGE BG-10C������������������������������������������������� 82 CPAGE
C-123L/A����������������������������������������������� 69 *3 C-D�������������������������������������������������������� 69 C-ML/A�������������������������������������������������� 69
DPAGE DA-1ASK����������������������������������������������� 67 DA-1DS�������������������������������������������� 64,67 DA-1MD������������������������������������������� 64,67 DA-2DS�������������������������������������������� 65,68 DA-4DG�������������������������������������������� 65,68 DA-4DS�������������������������������������������� 65,68 DAW-P������������������������������������ 64,66,67,68 DB-1MD�������������������������������������� 64,65,85 DB-1SD��������������������������������������� 64,65,85 DBS-1AK����������������������������������������������� 64 DE-UR��������������������������������������������������� 87 EPAGE EL-12S�������������������������������������������������� 98 GPAGE GF-10KP������������������������������������������������ 22 GF-1P���������������������������������������������������� 22 GF-2B���������������������������������������������������� 22 GF-2F���������������������������������������������������� 22 GF-2P���������������������������������������������������� 22 GF-3B���������������������������������������������������� 22 GF-3F���������������������������������������������������� 22 GF-3P���������������������������������������������������� 22 GF-4P���������������������������������������������������� 22 GF-AP���������������������������������������������������� 21 GF-BP���������������������������������������������������� 21 GF-nBA������������������������������������������������� 22 GFW-S��������������������������������������������������� 28 GT-10K�������������������������������������������������� 22 GT-1A���������������������������������������������������� 26 GT-1C���������������������������������������������������� 25 GT-1C-GD���������������������������������������������� 25 GT-1C-SL����������������������������������������������� 25 GT-1C-L������������������������������������������������� 25 GT-1C-L-BK������������������������������������������� 25 GT-1D���������������������������������������������������� 26
103
GT-1M-L������������������������������������������������ 26 GT-2C���������������������������������������������������� 25 GT-2C-L������������������������������������������������� 25 GT-2H���������������������������������������������������� 25 GT-2H-L������������������������������������������������� 25 GT-4B���������������������������������������������������� 22 GT-4F���������������������������������������������������� 22 GT-4Z���������������������������������������������������� 28 GT-AC���������������������������������������������������� 21 GT-AD���������������������������������������������������� 21 GT-BC���������������������������������������������������� 28 GT-BCX�������������������������������������������������� 29 GT-D������������������������������������������������������ 27 GT-DA���������������������������������������������������� 21 GT-DA-L������������������������������������������������ 21 GT-DM��������������������������������������������������� 21 GT-DP���������������������������������������������������� 21 GT-DP-L������������������������������������������������ 21 GT-HID��������������������������������������������������� 21 GT-HS���������������������������������������������������� 25 GT-MK��������������������������������������������������� 28 GT-nH���������������������������������������������������� 22 GT-nHB�������������������������������������������������� 22 GT-NS���������������������������������������������������� 22 GT-NSP-L���������������������������������������������� 22 GT-RY���������������������������������������������������� 29 GT-SW��������������������������������������������������� 22 GT-VA���������������������������������������������������� 21 GT-VBC�������������������������������������������������� 28 GT-VBX�������������������������������������������������� 29 GT-VP���������������������������������������������������� 21 GTW-LC������������������������������������������������� 30
IPAGE
IAI-100�������������������������������������������������� 90 IAX-100������������������������������������������������� 90 IE-1AD(U)���������������������������������������������� 70 IE-1GD(U)���������������������������������������������� 71 IE-2A2DU���������������������������������������������� 72 IE-2AD(U)���������������������������������������������� 72 IE-8HD�������������������������������������������������� 73 IE-8MD�������������������������������������������������� 73 IE-SS/A������������������������������������������������� 74 IEH-1C2D���������������������������������������������� 72 IEH-1CD������������������������������������������� 71,72 IE-JA����������������������������������������������������� 72 IER-2����������������������������������������������������� 98 IF-DA����������������������������������������������������� 87 IME-100������������������������������������������������ 89 IME-150������������������������������������������������ 90 IMU-100������������������������������������������������ 89 IS-CCU�������������������������������������������������� 59 IS-DV����������������������������������������������������� 55 IS-DVF��������������������������������������������������� 55 IS-IPC���������������������������������������������������� 54 IS-IPDV�������������������������������������������������� 53 IS-IPDVF������������������������������������������������ 53 IS-IPMV������������������������������������������������� 53 IS-MV���������������������������������������������������� 55 IS-PU-S������������������������������������������������� 58 IS-RCU�������������������������������������������������� 56 IS-RS����������������������������������������������������� 56 IS-SCU�������������������������������������������������� 56 IS-SOFT������������������������������������������������� 54 IS-SS����������������������������������������������������� 56 IS-SS-2G����������������������������������������������� 56 IS-DVF��������������������������������������������������� 55 ISE-100������������������������������������������������� 90 IS-WBCA����������������������������������������������� 45
IS-WBCE����������������������������������������������� 45 IS-WBHA����������������������������������������������� 45 IS-WBHE����������������������������������������������� 45 IX-1AS��������������������������������������������������� 46 IX-10AS������������������������������������������������� 46 IX-BA����������������������������������������������������� 43 IX-DA����������������������������������������������������� 44 IX-DF����������������������������������������������������� 44 IX-DF-2RA��������������������������������������������� 45 IX-DF-P������������������������������������������������� 44 IX-DF-PI������������������������������������������������ 44 IX-MV���������������������������������������������������� 43 IX-SS����������������������������������������������������� 43 IX-SS-RA����������������������������������������������� 45 IX-SS-2RA��������������������������������������������� 45
JPAGE JF-2HD�������������������������������������������������� 14 JF-2MED����������������������������������������������� 13 JF-2SD�������������������������������������������������� 14 JF-D������������������������������������������������������ 13 JF-DA���������������������������������������������������� 13 JF-DV���������������������������������������������������� 13 JF-DVF�������������������������������������������������� 13 JFS-2AED���������������������������������������������� 14 JFS-2AEDV�������������������������������������������� 14 JFS-2AEDF�������������������������������������������� 14 JK-1HD������������������������������������������������� 10 JK-1MED������������������������������������������������� 9 JK-1SD�������������������������������������������������� 10 JK-DA������������������������������������������������� 9,27 JK-DV������������������������������������������������� 9,27 JK-DVF����������������������������������������������� 9,27 JK-DVF-AC�������������������������������������������� 10 JKS-1ADF��������������������������������������������� 10 JKS-1AED��������������������������������������������� 10 JKS-1AEDF������������������������������������������� 10 JKS-1AEDV������������������������������������������� 10 JKW-BA������������������������������������������������� 11 JKW-IP�������������������������������������������������� 12 JO-1MD��������������������������������������������������� 8 JO-1FD���������������������������������������������������� 7 JO-DVF���������������������������������������������������� 7 JO-DV������������������������������������������������������ 7 JO-DA����������������������������������������������������� 7 JOS-1A���������������������������������������������������� 8 JOS-1F���������������������������������������������������� 8 JOS-1V���������������������������������������������������� 8 JP-4HD���������������������������������������������� 4,78 JP-4MED�������������������������������������������� 3,77 JP-8Z������������������������������������������������� 4,78 JP-DA������������������������������������������������� 3,77 JP-DV������������������������������������������������� 3,77 JP-DVF����������������������������������������������� 3,77 JP-DVF-L�������������������������������������������� 3,77 JPEC������������������������������������������������������� 4 JPS-4AED����������������������������������������������� 4 JPS-4AEDF���������������������������������������������� 4 JPS-4AEDV��������������������������������������������� 4 JPTIIP������������������������������������������������������ 3 JPW-BA��������������������������������������������������� 6 Jx-DVF-AC������������������������������������������� 4,8 KPAGE
KAW-D��������������������������������������������������� 97
LPAGE LE-A������������������������������������������������������ 84 LE-AN���������������������������������������������������� 84 LE-D������������������������������������������������������ 84
LE-DA��������������������������������������������������� 84 LE-DL��������������������������������������������������� 84 LEF-10������������������������������������������������� 81 LEF-10C����������������������������������������������� 83 LEF-10S����������������������������������������������� 81 LEF-10W���������������������������������������������� 81 LEF-1C�������������������������������������������� 83,84 LEF-3��������������������������������������������������� 81 LEF-3C������������������������������������������������� 83 LEF-3L������������������������������������������������� 81 LEF-5W������������������������������������������������ 81 LEM-1�������������������������������������������������� 80 LEM-1DL���������������������������������������������� 79 LEM-3�������������������������������������������������� 80 LE-SS-1G��������������������������������������������� 84 LE-SS/A����������������������������������������������� 84 LEW-10������������������������������������������������ 82 LEW-10S���������������������������������������������� 82 LEW-5�������������������������������������������������� 82
TOWER������������������������������������������������� 45
WPAGE W-DIN11���������������������������������������������� 29 YPAGE YAW-RB������������������������������������������������ 86 YAZ-90-3W������������������������������������������� 86 *3 Not available separately
MPAGE MC-60/4A�������������������������������������������� 94 MC-A/A������������������������������������������������ 94
PPAGE PD-1����������������������������������������������������� 88 PD-2����������������������������������������������������� 88 6VDC2500/1����������������������������������������� 99 PS-1225����������������������������������������������� 99 PS-1820����������������������������������������������� 99 PS-2420����������������������������������� 29,58,100 16VAC1500/5��������������������������������������� 99
RPAGE RY-3DL��������������������������������������������������� 6 RY-AC/A����������������������������������������������� 98 RY-ES��������������������������������������������������� 75 RY-IP44������������������������������������������������ 46 RY-PA��������������������������������������������������� 98 SPAGE SBX-1G������������������������������������������������ 97 SBX-2G������������������������������������������������ 97 SBX-AXDVF������������������������������������������ 97 SBX-DV30�������������������������������������������� 97 SBX-DVF���������������������������������������������� 97 SBX-DVF-P������������������������������������������� 97 SBX-GTDM������������������������������������������� 22 SBX-ISDVF�������������������������������������� 46,97 SBX-ISDVFP����������������������������������������� 97 SBX-ISDVFRA���������������������������������� 46,97
TPAGE TB-AD1������������������������������������������������ 93 TB-AD10���������������������������������������������� 93 TB-SE��������������������������������������������������� 92 TC-10M������������������������������������������� 91,93 TC-20G������������������������������������������������� 92 TC-20M������������������������������������������������ 91 TC-40G������������������������������������������������� 92 TC-40GS����������������������������������������������� 92 TD-12H/B��������������������������������������������� 88 TD-1H/B����������������������������������������������� 87 TD-24H/B��������������������������������������������� 88 TD-3H/B����������������������������������������������� 87 TD-6H/B����������������������������������������������� 87 TDW-1/A���������������������������������������������� 88 TDW-12/A�������������������������������������������� 88 TDW-24/A�������������������������������������������� 88 TDW-3/A���������������������������������������������� 88 TDW-6/A���������������������������������������������� 88
104
ISO 14001
ISO 9001
ISO 14001 Certified
ISO 9001 Certified
JQA-EM0453 Headquarters section Toyota Factory Taiho Site
AIPHONE CO., LTD.
JQA-0291
Deming Prize
Deming Medal
AIPHONE CO., LTD.
AIPHONE PTY LTD
Unit 11A, 2 Eden Park Drive Macquarie Park, NSW 2113 Australia Tel.: 02-8036-4507 URL: http://www.aiphonepty.com.au/
GLC2015-16(AU)
Pr i nt ed i n J apan
AZ57058AJZ