Preview only show first 10 pages with watermark. For full document please download

General Purpose Relays 8501k

   EMBED


Share

Transcript

Square D General Purpose Relays Class 8501K universal relays Catalog 2014 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com Contents Square D™ General Purpose Relays Class 8501K universal relays bb Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 bb References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 bb Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 bb Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com Square D General Purpose Relays Specifications Class 8501K universal relays General Specifications Conforming to standards Product certifications Ambient air temperature around the device Storage Operation Vibration resistance In operation conforming to IEC/EN 60068-2-6 Not operating Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position °C (F) °C (F) Rated insulation voltage (Ui) V Insulation Specifications Conforming to IEC/EN 60947 IEC/EN 61810-1, UL 508, CSA C22-2 n° 14 cULus File E3190 CCN NLDX, NLDX7; cURus File E3190 CCN NLDX2, NLDX8; CSA; CE; RoHS compliant - 40 to + 85 (-40 to +185) - 40 to + 55 (-40 to +131) 3 gn (35 to 150 Hz) and ± 1 mm (10 to 35 Hz); 5 cycles 4 gn (35 to 150 Hz) and ± 1 mm (10 to 35 Hz); 5 cycles IP 40 (housing only) 10 gn (11 ms) 10 gn (11 ms) RT I Any 250 (IEC), 300 (UL, CSA) Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 µs) Dielectric strength (rms voltage) Vac Vac Vac 2500 2000 1500 Between coil and contact Between poles Between contacts Contact Specifications Relay type 8501KFR12ppp, 8501KFRD12ppp, 8501KPR12ppp, 8501KPRD12ppp, 8501KUR12ppp, 8501KURD12ppp 8501KFR13ppp, 8501KFRD13ppp, 8501KPR13ppp, 8501KPRD13ppp, 8501KUR13ppp, 8501KURD13ppp Number and type of contacts 2 C/O 3 C/O Contact materials AgNi Conventional thermal current (Ith) For ambient temperature y 55°C Rated operational current Conforming to IEC in utilization categories AC-1 and DC-1 Conforming to UL A 10 NO A 10 at 250 Vac 10 at 28 Vdc NC A 5 at 250 Vac 5 at 28 Vdc Resistive A 10 at 277 Vac (200k cycles) 10 at 30 Vdc (200k cycles) Motor HP 1/3 at 120 Vac (6k cycles) 1 at 277 Vac (6k cycles) Pilot Duty B300 (6k cycles) Minimum switching requirement mA 10 @ 17 Vdc; MCTF ≥ 10 million Maximum switching voltage V 250 V (IEC) / 300 V (UL,CSA) Switching capacity Maximum Minimum Maximum operating rate In operating cycles/hour Vac VA 2500 VA (IEC), 2770 VA (UL) Vdc W 280 W (IEC) / 300 W (UL) mW 170 No-load 18000 Under load 1200 Utilization coefficient 20% Mechanical durability Cycles 5,000,000 Electrical durability Operating cycles Resistive load Inductive load 100,000 (unless otherwise specified) See curve below Reduction coefficient (A) Electrical durability of contacts Resistive load Vac Reduction coefficient for inductive load Vac (depending on power factor cos ϕ) 1 0.8 0.6 0.5 0.4 0.3 1 0.6 0.4 0.2 Durability (inductive load) = durability (resistive load) x reduction coefficient. ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com 3 Square D General Purpose Relays Specifications (continued) Class 8501K universal relays Coil Specifications Average consumption VA 3 W 1.4 Drop-out voltage threshold u 0.15 Uc (at minimum operating temperature) u 0.1 Uc (at minimum operating temperature) Response time Operate time ms 20 max (at 100% coil voltage) Release time ms 20 max V 12 24 48 110 120 240 V51 V53 V56 V60 – – Control circuit voltage Uc Relay control voltage codes DC supply Average resistance at 20 °C ± 15% Ω 120 470 1800 7300 – – Operating voltage limits Min. Vac 9.6 19.2 38.4 88 – – Max. Vac 13.2 26.4 52.8 121.0 – – – V14 – – V20 V24 Relay control voltage codes AC supply Average resistance at 20 °C ± 15% Ω – 72 – – 1700 6800 Operating voltage limits Min. Vac – 19.2 – – 96 192 Max. Vac – 26.4 – – 132 264 8501NR52 8501NR62 Socket Specifications(1) Socket type 8501NR51 Relay types used 8501KPR12ppp, 8501KPR13ppp, 8501KPR12ppp, 8501KPR13ppp, 8501KUR13ppp, 8501KPDR12ppp 8501KPDR13ppp 8501KPDR12ppp 8501KPDR13ppp 8501KUDR13ppp 8501NR61 Contact terminal arrangement Mixed Wire connection method Screw clamp terminal Product certifications cURus File E66924 CNN SWIV2, SWIV8; CSA; CE; RoHS Compliant Conforming to standards IEC 61984, UL 508, CSA 22.2 No. 14 Electrical Specifications Conventional thermal current (Ith) A Insulation Specifications 8501NR82 Separate 15 at 300 Vac (UL) 5 at 600 Vac (UL) 16 at 300 Vac (UL) 5 at 600 Vac (UL) 15 at 300 Vac (UL) 2000 Between adjacent output contacts Vrms 2000 2500 Between input and output contacts Vrms 2000 2500 2000 Between contacts and DIN rail Vrms 2000 2500 2000 Ambient air temperature Storage around the device Operation °C (F) - 40 to + 85 (-40 to +185) General Specifications °C (F) - 40 to + 55 (-40 to +131) Degree of protection Conforming to IEC/EN 60529 IP 20 Cabling Solid cable without cable end 1 conductor 0.5 to 2.5 mm2 - AWG 20 to AWG 14 2 conductors 0.5 to 1.5 mm2 - AWG 20 to AWG 16 1 conductor 0.25 to 2.5 mm2 - AWG 22 to AWG 14 2 conductors 0.25 to 1 mm2 - AWG 22 to AWG 17 Flexible cable with cable end Maximum tightening torque / Screw size Lb-ft 0.7 (1) / M3.5 screw (N•m) Mounting On 35 mm DIN rail / on panel Mounting on DIN rail By red plastic clip Terminal referencing IEC, NEMA Bus jumper None Compatible hold down clip None 8501NH52 8501NH82 Compatible restraining strap 8501NH7 8501NH7 8501NH7 Wire connection method Screw clamp terminals (1) Sockets are rated as high as 600 V. 4 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com Square D General Purpose Relays References Class 8501K universal relays References Pins Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O - 10 A 3 C/O - 10 A Unit reference Weight Unit reference kg/lb Universal relays with standard clear cover (sold in lots of 1) Type KP Cylindrical terminals Socket mount Type KU Flat (Faston type) terminals Socket mount 8501KPDR12V60 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 8501KPDR12V51 8501KPDR12V53 8501KPDR12V56 8501KPDR12V60 8501KPR12V14 8501KPR12V20 8501KPR12V24 8501KUDR12V51 8501KUDR12V53 8501KUDR12V56 8501KUDR12V60 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 8501KPDR13V51 8501KPDR13V53 8501KPDR13V56 8501KPDR13V60 8501KPR13V14 8501KPR13V20 8501KPR13V24 8501KUDR13V51 8501KUDR13V53 8501KUDR13V56 8501KUDR13V60 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 24 Vac 120 Vac 240 Vac 8501KUR12V14 8501KUR12V20 8501KUR12V24 0.086/0.190 0.086/0.190 0.086/0.190 8501KUR13V14 8501KUR13V20 8501KUR13V24 0.086/0.190 0.086/0.190 0.086/0.190 8501KFDR12V51 8501KFDR12V53 8501KFDR12V56 8501KFDR12V60 8501KFR12V14 8501KFR12V20 8501KFR12V24 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 8501KFDR13V51 8501KFDR13V53 8501KFDR13V56 8501KFDR13V60 8501KFR13V14 8501KFR13V20 8501KFR13V24 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 8501KPDR12P14V51 8501KPDR12P14V53 8501KPDR12P14V56 8501KPDR12P14V60 8501KPR12P14V14 8501KPR12P14V20 8501KPR12P14V24 8501KUDR12P14V51 8501KUDR12P14V53 8501KUDR12P14V56 8501KUDR12P14V60 8501KUR12P14V14 8501KUR12P14V20 8501KUR12P14V24 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 8501KPDR13P14V51 8501KPDR13P14V53 8501KPDR13P14V56 8501KPDR13P14V60 8501KPR13P14V14 8501KPR13P14V20 8501KPR13P14V24 8501KUDR13P14V51 8501KUDR13P14V53 8501KUDR13P14V56 8501KUDR13P14V60 8501KUR13P14V14 8501KUR13P14V20 8501KUR13P14V24 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 Universal relays with flange mount cover (sold in lots of 1) Type KF Flat (Faston type) terminals Flange mount 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 120 Vac 240 Vac Universal relays with standard clear cover and LED (sold in lots of 1) Type KP Cylindrical terminals 8501KPR13P14V20 Type KU Flat (Faston type) terminals Weight kg/lb 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 120 Vac 240 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 120 Vac 240 Vac 8501KUDR12P14V60 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com 5 References (continued) Square D General Purpose Relays Class 8501K universal relays References (continued) Sockets Contact terminal arrangement Mixed 8501NR62 + Relay 8501KPR13P14V20 Separate Connection Relay type Unit reference(1) Sold in lots of Screw connector 8501KPR12ppp 8501KPDR12ppp 8501NR51 1 0.054/0.119 8501KPR12ppp 8501KPDR12ppp 8501NR51B 10 0.054/0.119 8501KPR13ppp 8501KPDR13ppp 8501NR61 1 0.054/0.119 8501KPR13ppp 8501KPDR13ppp 8501NR61B 10 0.054/0.119 8501KPR12ppp 8501KPDR12ppp 8501NR52 1 0.054/0.119 8501KPR12ppp 8501KPDR12ppp 8501NR52B 10 0.054/0.119 8501KPR13ppp 8501KPDR13ppp 8501NR62 1 0.054/0.119 8501KPR13ppp 8501KPDR13ppp 8501NR62B 10 0.054/0.120 8501KUR12ppp 8501KUDR12ppp 8501NR82 1 0.054/0.121 8501KUR12ppp 8501KUDR12ppp 8501NR82B 10 0.054/0.122 Screw connector Weight kg /lb (1) Please note that the “B” suffix only desginates quantities of 10 and is not printed on the socket. 8501NR82 + Relay 8501KUDR12P14V60 Accessories Description 8501NH7 For use with Unit reference Sold in lots of Metal restraining strap 8501NR51 sockets 8501NR52 sockets 8501NR62 sockets 8501NR82 sockets 8501NH7 1 0.001/0.002 Metal hold-down clip 8501NR52 sockets 8501NR62 sockets 8501NH52 10 0.001/0.002 8501NR82 sockets 8501NH82 10 0.001/0.002 8501NH52 8501NH82 6 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com Weight kg/lb Square D General Purpose Relays Dimensions Class 8501K universal relays Dimensions: inches (mm) Universal relays 8501KF12ppp / 8501KF13ppp 1.9 (49.6) 0.032 (0.81) 2.75 (70.0) 0.27 (6.8) 2.38 (60.5) 0.16 (4.0) 0.11 (2.8) 0.062 (1.58) 0.63 (15.88) 8501KP12ppp 1.4 (35.4) 2.1 (50.3) 1.4 (34.9) 8501KP13ppp 1.4 (35.4) 2.1 (50.3) 1.4 (34.9) 8501KU12ppp / 8501KU13ppp 1.4 (35.4) 1.97 (50.0) 1.37 (34.9) ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com 7 Square D General Purpose Relays Dimensions (continued) Class 8501K universal relays Dimensions: inches (mm) (continued) Sockets 8501NR51 8501NR61 1.6 (40) 1 2.02 (51) 1.29 (33) 8 0.59 (15) 2.32 (59) 0.97 (24.6) 7 0.97 (24.6) 1.6 DIA. (40) 0.16 (4.2) 2 2.12 (54) 1 2.05 (52) 11 2 10 3 4 1.01 (25.6) 3 4 5 1.02 (25) 6 8501NR52 1.42 (36) 2.06 (52) 9 8 5 2.16 (54.8) 7 6 8501NR62 1.45 (37) 1.42 (36) 1.1 (27.9) 3.0 (77.5) 22 11 12 5 1 4 24 21 14 6 8 3 1.5 (38) 1.1 (27.9) 3.19 (81) 0.15 (3.8 3.02 (76.8) 2.86 (72.7) 1.58 (40) 32 24 22 8 7 5 21 31 11 6 12 4 11 1 34 14 9 3 1.58 (40) IEC: NEMA: IEC: NEMA: A2 INPUT 7 A2 INPUT 10 A1 INPUT 2 A1 INPUT 2 1.35 (34.2) 1.2 (30) 8501NR82 6 3 2 3.0 (76) 1.37 (35) 5 0.4 (10) 1.69 (43) 1 1.53 (39) 4 1.03 (26) 0.15 (3.81) 3.14 (80) B A 1.5 (38) 9 8 8 7 ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com 0.15 (3.8 Square D General Purpose Relays Wiring diagrams Wiring diagrams Universal relays DPDT 1 3 22 4 6 5 22 3 6 14 24 1 8 11 31 2 7 8501KP12ppp 24 7 9 11 21 NEMA IEC B A2 24 5 8 22 32 3 7 9 14 24 34 1 6 11 11 21 31 2 10 A1 A2 12 4 6 3 21 6 22 5 24 7 9 3 7 A1 2 8 31 10 11 11 11 1 3PDT 8501KF13ppp / 8501KU13ppp 32 8 14 A2 A1 2 1 A A1 4 12 8501KP13ppp 22 5 12 4 14 14 Class 8501K universal relays A2 A1 8501KF12ppp / 8501KU12ppp 12 4 12 34 A2 31 1 2 3 12 32 22 4 5 6 14 34 24 7 8 9 11 31 21 A B A1 A2 NEMA IEC NEMA IEC NEMA IEC Sockets 8501NR51 8501NR61 A1 11 21 A2 2 1 8 7 INPUT 1 14 INPUT 8 2 11 31 1 11 A1 3 INPUT 1 4 9 4 8 5 4 5 12 3 4 5 6 14 12 22 24 7 6 5 24 21 NEMA IEC 8501NR52 8501NR62 8501NR82 22 11 12 32 24 22 12 24 34 5 1 4 8 7 5 4 6 5 4 24 21 14 31 21 11 22 32 12 6 8 3 11 6 1 3 2 1 14 34 5 9 4 6 3 7 2 6 7 3 5 8 8 INPUT NEMA IEC A1 A2 2 1 5 4 9 8 Coil Bus Jumper INPUT NEMA IEC 2 A1 B A2 INPUT N.C. N.O. 7 COM A INPUT 1 MODULE INPUT 10 2 3 6 B 2 11 MODULE INPUT Coil Bus Jumper 3 10 1 14 4 9 A2 8 32 7 6 22 NEMA IEC 7 9 10 3 6 34 INPUT 11 2 7 3 A2 10 2 A A1 9 8 7 21 31 11 NEMA IEC ™ Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com 9 Schneider Electric USA, Inc. 8001 Knightdale Blvd. Knightdale, NC 27545 Tel: 888-778-2733 www.schneider-electric.com Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. © 2014 Schneider Electric. All Rights Reserved. Schneider Electric and Square D are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are the property of their respective owners. 8501CT1406, 09/2014 Replaces 8501CT0301R07/08, 08/2008 Courtesy of Steven Engineering, Inc. - (800) 258-9200 - [email protected] - www.stevenengineering.com