Preview only show first 10 pages with watermark. For full document please download

Generators 6 To 45kw..

   EMBED


Share

Transcript

Diesel Generators 6 kw - 45 kw Open & Enclosed Generators Standard Features Enclosed Generators 6 - 45 kw The MasPower series generators are powered by 1800 RPM water-cooled Yanmar diesel engines. They not only meet all of today’s stringent emissions regulations but are designed to meet those of the future. They beat the competition with their low noise levels, making them ideal for a wide range of applications. These units are the best in their class for fuel economy resulting in reduced operation costs. The engines are coupled with heavy duty 12 lead re-connectable generators. This allows the units to be wired for single or three phase at a wide range of voltages. They are self-exciting, synchronous, and brushless permanent magnet generators. Open Generators 6 - 45 kw MasPower’s MEC series of heavy duty generators are powered by a proven Yanmar diesel engine. Operating at 1800 RPM, the Yanmar diesel offers long life, reduced fuel consumption and smooth, quiet service. The engines are radiator-cooled and coupled to a brushless generator. The generator set includes: automatic shutdowns for low oil pressure and high water temperature, primary fuel filter, 12 volt starting, muffler, owner’s manual and skid mounted. • Lift off lockable doors and control panel cover for ease of maintenance • Vibration isolation mounting between engine/ generator feet and base frame • Insulation class H • Double walled UL 142 listed based fuel tank on enclosed standby units • Heavy duty dry type air filter • Battery charging alternator • Battery rack, cables, and charger • Exhaust silencer, residential and critical • Oil drain plumbed to frame • Weatherproof , powder coated aluminum sound attenuated cabinet • Deep sea 5110 digital controller with remote start • Main line circuit breaker • Lug Connections Options • • • • • • • • • • Skid mounted Single or three phase DOT Approved Trailers Wire Reels Multi-phase/voltage selector switches Various fuel tank sizes to extend run times Block heater Cam connectors or Polaris quick connections 50 Hz Low fuel level shutdown MasPower Generator Performance Specifications (6 kw - 45 kw Open & Enclosed Generators, 1800 RPM) Product MEC 14 DSA Single Ф MEC 14 DSA Three Ф MEC 16 DSA Single Ф MEC 16 DSA Three Ф MEC 18 DSA Single Ф MEC 18 DSA Three Ф 14 14 16 16 18 18 56x29x38” 56x29x38” 56x29x38” 56x29x38” 67x29x54” 67x29x54” Weight 1036 lbs 1036 lbs 1069 lbs 1069 lbs 1280 lbs 1280 lbs Voltage 240 VAC Single Ф 240 VAC Three Ф 240 VAC Single Ф 240 VAC Three Ф 240 VAC Single Ф 240 VAC Three Ф 58 42 67 48 75 54 Yanmar 3TNV88 Yanmar 3TNV88 Yanmar 3TNV84T Yanmar 3TNV84T Yanmar 4TNV88 Yanmar 4TNV88 43 43 43 43 43 43 Approx. fuel burn at 100% load 1.36 gph 1.36 gph 1.58 gph 1.58 gph 1.76 gph 1.76 gph Approx. run time at 65% load 59 hrs 59 hrs 51 hrs 51 hrs 45 hrs 45 hrs Standby kw Dimensions (LxWxH) Amps at rated voltage with .8 power factor Engine Fuel tank size on enclosed units* MasPower Generator Performance Specifications (6 kw - 45 kw Open & Enclosed Generators, 1800 RPM) Product Standby kw Dimensions (LxWxH) MEC 22 DSA Single Ф MEC 22 DSA Three Ф MEC 35 DSA Single Ф MEC 35 DSA Three Ф MEC 45 DSA Single Ф MEC 45 DSA Three Ф 22 22 35 35 45 45 67x29x54” 67x29x54” 85x34x66” 85x34x66” 85x34x66” 85x34x66” Weight 1630 lbs 1630 lbs 1880 lbs 1880 lbs 1880 lbs 1880 lbs Voltage 240 VAC Single Ф 240 VAC Three Ф 240 VAC Single Ф 240 VAC Three Ф 240 VAC Single Ф 240 VAC Three Ф 92 66 146 105 188 135 Yanmar 4TNV84T Yanmar 4TNV84T Yanmar 4TNV98 Yanmar 4TNV98 Yanmar 4TNV98T Yanmar 4TNV98T 43 43 80 80 80 80 Approx. fuel burn at 100% load 2.07 gph 2.07 gph 2.96 gph 2.96 gph 3.86 gph 3.86 gph Approx. run time at 65% load 77 hrs 77 hrs 54 hrs 54 hrs 41 hrs 41 hrs Amps at rated voltage with .8 power factor Engine Fuel tank size on enclosed units* *Call factory for optional sizes Weights and measurements relate to DSA units