Generex Cables

   EMBED


Share

Transcript

Version: 2016-08-18 Cabletypes for UPS software GENEREX UNIX port cables are to be used only with potential free relais UPS and with „no modem“ control settings at their tty ports. Modem port cables are used with any standard PC serial layout or with UNIX systems supporting full compatibility and GENEREX version above 3.x. Modemport Cabletype blue: (no shield, length 90 cm) D-Sub 9 femail D-Sub 9 mail 1--------------------------------------------------------- 5 2----------------------------------------------------------9 3----------------------------------------------------------6 4----------------------------------------------------------1 5----------------------------------------------------------4 6----------------------------------------------------------2 7 7 8----------------------------------------------------------3 9 R = 328 Kohm (0,328 MΩ) Cabletype X34: UNIX RCLOSED / RCLOSED, (Universal cable for any UPS with a single dry contact and UPSMAN software settings RCLOSED or ROPENED). For use with Multiplexer Multi4 N2 in conjunction with UNIX. Length 1.8 m Cabletype X24: UNIX OPENED / ROPEN, ( for CHLORIDE EDP 20 (10-18) and BICKER IPS 300 UNIX) UPS 9pol/male PF UNIX computer 9pin/female 2---------------------------3 Common 4---------------------------2 Cabletype X59: UNIX OPENED / ROPEN, ( for CHLORIDE EDP 20(10-18), 30,50,70,90 UNIX) UPS 9pol/male UNIX computer 9pin/female PF 9---------------------------3 Common 5---------------------------2 Cabletype 1: old cable / See archives Modemport Cabletype 2: (for use with all UPS from PHOENIX, ONLINE, Fairstone and types without Pin3 for UPS OK) UPS (Normal c.c. 3+4) Powerfail 2 4,7KOhm 4 O.K. NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 3 9 Low High High High Low 4,7KOhm Battery Low 5 8 High UPS Shutdown 6 7 Output 7 5 GND Modemport Cabletype 3: (for use with CHLORIDE EDP 20 (10-18), software settings 2) UPS side 9pin/male, PC side 9pin/female UPS (Normal c.c. 2+6) Powerfail GND 2 4,7KOhm 4 NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 4,7KOhm O.K. 6 9 Low High High 5 8 High High Low 3 7 5 GND 4,7KOhm Battery Low 2017-07-17 Modemport Cabletype 4: (for use with ONLINE B-series bis Bj 96, Sinetec Booster over 1000 VA, since 1994) UPS (Normal c.c. 1+4) Powerfail 2 4,7KOhm 4 NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 4,7KOhm O.K. 1 9 Low High High 5 8 High High Low 6 7 Output 7 5 GND 4,7KOhm Battery Low UPS Shutdown Modemport Cabletype 5: (for CHLORIDE EDP 20(10-18), EDP30,50,70,90, software-settings Type 2 / CLOSED) UPS side 9pin/male, PC side 9pin/female UPS (Normal c.c. 2+5) Powerfail GND 9 4,7KOhm 5 NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 4,7KOhm O.K. 2 9 Low High High 8 High High Low 4,7KOhm Battery Low 7 5 GND Modemport Cabletype 5/2: (for use with CHLORIDE EDP 30 MK1, EDP 50, 70, 90, softwaresettings 2 / CLOSED) 2017-07-17 UPS (Normal c.c. 2+5) Powerfail GND 9 NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4,7KOhm 5 4 + 12 V 4,7KOhm O.K. 2 9 Low High High 8 High High Low 4,7KOhm Battery Low 7 5 GND Cabletype 6 (and cable 2): (Universal cable for most UPS types with dry-contacts or opt isolated relays and up to 3 alarms, eg. ONLINE YUNTO P, CHLORIDE EDP10, Phoenix, and others). Works with all UPSMAN Windows, OS/2, Netware and most UNIX versions. For use with Multi4 N2 in conjunction with Windows. (except SUN Solaris and HP UNIX). Length 1.8 m. UPS (Normal c.c. 3+4) Powerfail 2 NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4,7KOhm 4 4 + 12 V 4,7KOhm O.K. 3 9 Low High High High Low 4,7KOhm Battery Low 5 8 High UPS Shutdown 6 7 Output 7 5 GND Modem Cabletype 7: (for use with most RIELLO / ERREPI UPS Types SBS 600 and CP 300500, software settings „6“) UPS (Normal c.c. 2+4) 9pin male Powerfail 3 4,7KOhm 4 O.K. 9pin female NOVELL COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 4,7KOhm 2 9 Low High High High Low 4,7KOhm Battery Low 5 8 High UPS Shutdown 6 7 Output 7 5 GND Cabletype 7_I : (modified Cable 6 with Bypass,) USE with Power Generator: 2017-07-17 Powerfail = Powerfailure, Generator started = Bypass, Generator switch closed = Battery Low. DB 9 male DB 9 female Cable type 7_II: (modified Cable 6 with Bypass). Universal cable for Liebert UPS RelayCardSLI-23210_EN types with dry-contacts or opt isolated relays and bypass alarm. . (Use logic "cable 7" ) JP01 Pin 9 to Pin 17 Allows all relay COMMONS to be tied together DB 25 male DB 9 female UNIX port Cabletype 8: (for most RIELLO UPS, software-settings CLOSED) UPS UNIX COMPUTER (Normal c.c. 2+4) 2 D-SUB 9 male 4 3 2 SEND 3 RECEIVE D-SUB 9 female O.K. Cabletype 8_I: (modified Cable 6 with Bypass) . Universal cable for most UPS types with drycontacts or optoisolated relays and bypass alarm. 2017-07-17 DB 9 male DB 9 female Cabletype 8_II: Identical to cable 8_I, but resistors on PC side ! (modified Cable 6 with Bypass) . Universal cable for most UPS types with dry-contacts or optoisolated relays and bypass alarm. Normally closed. DB 9 male DB 9 female Cabletype 9_I : (modified Cable 2, inverted – this shows UPS in alarm state, Normal operation is contacts closed) UPS (Normal c.c. 2+4) Powerfail 2 4,7KOhm 4 O.K. UPSMAN/CS121 O.K. Powerfail Batt. Low 1 High Low Low 4 + 12 V 3 9 Low High High High Low 4,7KOhm Battery Low 5 8 High UPS Shutdown 6 7 Output 7 5 GND 2017-07-17 Cabletype 10_I : (modified Cable 7, inverted, with Bypass – this shows UPS in alarm state, Normal operation is contacts closed) DB 9 male DB 9 female UNIX port Cabletype 10 (for use with PILLER types AR 0.6, 01, 02, 3.5, 05, 0.6/19“, 01/19“, 02/19“ software-settings CLOSED and with EFFEKTA UPS 700/100/1400 i-net with serial communication) UPS UNIX COMPUTER (Normal c.c. 6+7) 2 D-S UB 9 female D-SUB 9 female 6 2 SEND 7 3 RECEIVE O.K. Attention : At UPS side 9 pin female connector ! Modemport Cabletype 10: (for use with all contact UPS with opening contacts at alarm) Zeichnung KABLE 10 – to be added by Mr. Wassmann. Cabletype 11: (1:1 cable, alike cable 11_1 but all pins connected. For use with ONLINE types 600 -2000 serial, CONVEREX, all ASTEC types. Powerbox dsp and some EMERSON types, Saphir AEC, ERREPI serie 2001/TTP/PILLER AR Power.) 2017-07-17 Cabletype 11_1: (1:1 cable, only pin 2, 3, and 5 connected! For most serial UPS like ONLIINE YUNOT Q, XANTO S, Piller AR1 6 plus and AR10plus, SAME Aline 2000 and Modular PWAEG with Ecowave and many others.) Length 1.8 m UPS COMPUTER RECEIVE 2 SEND 3 GROUND D-SUB 9 male 2 SEND 3 RECEIVE 5 GROUND D-SUB 9 female 5 Cabletype 12 : (Universal cable for most UPS types with dry-contacts or optoisolated relays up to 4 alarms. Powerfail, Battery low, General Alarm and Bypass ) Fig.: Screen of Cabletype12 UNIX port Cabletype12: (for use with PILLER AR 5-3/12, 7.5-3/1, 10-3/1, 15-3/1, 10-3/3, 15-3/3 software-settings CLOSED) UPS UNIX Port (Normal c.c. 3+4) Powerfail D-SUB 9 male 2 3 1 2 TX RS232 4 + 12 V 3 RX RS232 5 8 6 7 7 5 4 O.K. Battery Low UPS Shutdown D-SUB 9 female Cable shielded GND 2017-07-17 Attention : At UPS side 15 pin male connector ! Modemport Cabletype 13: (for use with PILLER types AR 5-3/12, 7.5-3/1, 10-3/1, 15-3/1, 103/3, 15-3/3) UPS NOVELL COMPUTER (Normal c.c. 6+14) D-S UB 15 male 13 Powerfail 4,7KOhm 14 O.K. 4,7KOhm 6 12 4 Battery Low O.K. Powerfail Batt. Low D-SUB 9 female 1 High Low Low 4 + 12 V 9 4,7KOhm 8 High High Low 7 Output 5 GND Modemport Cabletype 14: (Combicable for use with ONLINE ASTEC and P-series) UPS (Normal c.c. 3+4) O.K. NOVELL COMPUTER 2 4,7KOhm 4 Powerfail 4,7KOhm 3 1 2 3 4 9 4,7KOhm + 1N4007 - Battery Low 5 UPS Shutdown 6 7 7 5 8 GND Cabletype Type 15: (for use with ERREPI On Power, old version only) UPS ERREPI OP COMPUTER 1 6 2 4 5 D-SUB 9 male 3 8 D-SUB 9 female 2 5 1 GND 2017-07-17 Modemport Cabletype 16: (Universal serial cable for all chinese and taiwanese UPS, eg. ONLINE ZINTO D, ERREPI OP, Effekta all chinese types, Roton Rubin, Inform PPS Pyramid Plus, POWERCOM ULT, Mainpower UPS, Tumel STS and other . UPS COMPUTER TX 9 RX DTR 6 1 GND D-SUB 9 male D-SUB 9 female 7 2 RX 3 TX 4 5 DTR GND PYRAMID PLUS PIN CONFIGURATIONS 9PIN DSUB-MALE 5 5 4 8 2 2 1 1 7 7 3 3 8 PC (COM PORTS) 6 6 UPS HABERLEŞ ME ÇIKIŞI 9 9 4 9 PIN DSUB-FEMALE 2017-07-17 UPS SIDE Pin No 6 7 9 PC SIDE Pin No 3 5 2 OPTI-UPS – SINETEC – ONLINE ZINTO D For ZINTO D (our PS series), the use of pins are built in the circuit layout and we are not using pin2, 3 & 5 for send, receive & ground. The detailed function for pins are showed in our PS manual page18 as enclosed in the sample shipment. Here I list below for your reference. PIN1: UPS simulates a relay opening between pin 1 and pin 4 when input power fails. PIN2: UPS simulates a relay closing between pin 2 and pin 4 when input power fails. PIN3: UPS sends an RS-232 high (12V) within 1 second after input power fails. Pin 3 is normally at RS232 low level (-8V) PIN4: Common ground. PIN5: UPS simulates a relay closing when the battery inside the UPS has less than 2 minutes backup time left. PIN6: User sends a RS232 high level (5-15V) for 3 secs. This signal will turn off the UPS until proper input voltage returns. It can operate only if UPS is in battery mode. This pin is also used as the RS232 receiver pin (RXD) PIN7: Common ground. PIN8: (reserved) PIN9: RS232 transmitter pin (TXD) Note: 1.) pin 1,2 and pin 5 are open collector outputs which must be pulled up to a common referenced supply, switch rating: +40V, 0.15A non-inductive) 2.) pin 4 and 7 should only be connected to ground. Therefore, it's impossible to use 1:1 cable. Standard Cabletype 17: (for use with all UPS types. Computer side full equiped and shielded, UPS side open for custom configuration) COMPUTER DSub 9-pin female Includes 9-pin male conncetor and metallic cover 1 2 3 4 5 6 7 8 9 Shield 2017-07-17 Modemport Cabletype 18: (for use with ONLINE NetWare monitorboards , „Y“-Cable) Y-Kabel Typ 001007 Länge 2,5 m * 2 2 (9p ol D-Sub male) 4 5 2 ONLINE UPS (9p ol D-Sub male) 4 5 2 4 (9p ol D-Sub male) 5 Cabletype 19: (for use with ONLINE UPS and LANTASTIC OS, ONLINE Type 015001) ONLINE UPS (9pol female) LANTASTIC PC (9pol D-Sub male) Kabel (9pol D-Sub male) Kabel (9po D-Sub female) 2 4,7KOhm 8 7 4,7KOhm 5 1 4 3 6 4 7 5 Cabletype 20: (for use with ONLINE, PHOENIX, FAIRSTONE and IBM LAN SERVER 3.0 u. a. andere integrierte System, Hersteller ONLINE Type 003003) D-Sub 9 male D-Sub 25 female 4 4,7KOhm 2 5 4 6 7 4,7KOhm 5 8 2 20 7 Cabletype 21: Special cable ONLINE UPS & DataWatch UNIX for SIEMENS SS 97 ports SS97 UPS (DB 9 m) 2017-07-17 Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Receive/P ----------------------------------------------------> +12 Send/P --------------------------------------------------------> Reset/P Common 0 Volt Receive/N -----------------| Power On/Remote | Send/N ---------------------| Reset/N Pin 3 Pin 4 Cable constructions for special software features or Computer port types Cabletype 22: Für HPUNX V 9.xx und DataWatch 2.5bl Version Reference model : HP 9000/887S HP-UX hp A.09.04 D 9000/887 Prerequisites: Use SAM to setup a modem dial-out-port for the UPS. Use line "/dev/cul0p.." Connect hp-ux ADP2-Panel: See instructions below. * UPS Pin 3 (power ok) * UPS Pin 4 (common) * UPS Pin 5 (low bat) * UPS Pin 2 (power fail) to to to HP pin 2 (data from computer) HP pin 3 (data from computer) HP pin 4 (RTS) DO NOT CONNECT Instructions for connecting the UPS to ADP2-Panel on HP 9000 series (HPUX9.xxx) Create a dial-out-only Modem Port: 1. Start sam 2. Select the menu "Peripheral devices", press enter 3. Select the menu "Terminal and modems", press enter 4. Press "menubar on/off", select "actions", press enter 5. Select "Add modem" 6. Choose a free port and selct it 7. Select ONLY [x] use device for calling out DON'T START A GETTY-PROCESS ! 8. Select ok 9. Terminate sam For more information, refer to the sam-manual. Select the device-node culXpX (e.g. /dev/cul0p7). The settings /dev/tty0p7, /dev/cua0p7 or /dev/ttyd0p7 won't work ! Cabletype 23: Für SUN OS und DataWatch 2.5bl Version Reference model : SS-10/30 with Solaris 1 SS-1000 with Solaris 2.3 sparc 80486 PC with Solaris 2.4 01 i86pc Prerequisites: : SunOS coco 4.1.3_DB 23 sun4m : SunOS ora 5.3 Generic_Patch sun4d : SunOS garfield 5.4 Generic_101946- Connect sun (or any other computer with "normal" modem control) Use line /dev/cua.. resp. /dev/cua/... DSR works in Solaris 1, but not in Solaris 2 * UPS Pin 3 (power ok) * UPS Pin 4 (common) * UPS Pin 5 (low bat) * UPS Pin 2 (power fail) to to to to V24 pin V24 pin V24 pin V24 pin 3 (data to computer) 2 (data from computer) 8 (DCD) 5 (CTS) Cabletype 24: Für DEC OSF/1/DEC UNIX und DataWatch 2.5 bl Version Reference model : Alpha 3000 : OSF1 tukan V2.0 240 alpha 2017-07-17 Prerequisites: Connect DEC Alpha with OSF1 * UPS Pin 3 (power ok) * UPS Pin 5 (low bat) TOGETHER -- to to use line /dev/tty00 V24 pin 3 (data to computer) V24 pin 5 (CTS) -- ALL THREE and to V24 pin 6 (DSR) -- ALL THREE and to V24 pin 8 (DTR) -- ALL THREE TOGETHER -TOGETHER -* UPS Pin 4 (common) * UPS Pin 2 (power fail) to V24 pin 2 (data from computer) DO NOT CONNECT Modemport Cabletype 25 (identical to cable 11): (for use with HTSER/RIELLO/ERREPI HTX types, dlp serie, DIALOG and only Rs-232 communication) NEW: UPS/Sub-D 9pol/male computer/Sub-D 9pol/female 2-------------------------------------------------------------------2 3-------------------------------------------------------------------3 4-------------------------------------------------------------------4 5-------------------------------------------------------------------5 7-------------------------------------------------------------------7 8-------------------------------------------------------------------8 9-------------------------------------------------------------------9 OLD: (for use wit Piller AR1 3KVA, HTSER/RIELLO/ERREPI HTX, dlp serie) 2017-07-17 UPS COMP UTER RECEIVE Rx 3 2 SEND 7 3 RECEIVE GROUND 4 5 GROUND 12V High 8 7 1 6 8 4 RTS SEND Tx D-SUB 9 male D-SUB 9 female Modemport Cabletype 26: (for use with RIELLO/ERREPI VRX types, DIALOG-I, only Rs-232 communication) UPS COMPUTER RECEIVE Rx 2 SEND Tx D-SUB 9 male 1 GROUND 2 SEND 3 RECEIVE 5 GROUND D-SUB 9 female 9 Combi Modem Cabletype 27: (for use with VRX UPS contact closure + Rs232), software settings „2“/„6“ or serial) UPS (Normal c.c.6+4) 9pin male 4,7KOhm 9pin female COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 2 Send 3 Receive 4 + 12 V 9 Low High High Normal O.K. 3 2 1 4 6 Battery Low 5 8 High UPS Shutdown 6 7 Output 7 5 GND Powerfail Receive Rx Send Tx 4,7KOhm 4,7KOhm High Low 2017-07-17 Cabletype 28: : old cable CS 110/ See archives Combi Modem Cabletype 29: (for use with AEG CompuStar/Transcom/Safemaster contact closure + RS-232), software settings „2“ or serial) UPS (Normal Opened) 9pin male Powerfail Receive Rx Send Tx Battery Low UPS Shutdown 9 3 2 4 9pin female 4,7KOhm 4,7KOhm COMPUTER O.K. Powerfail Batt. Low 1 High Low Low 3 Send 2 Receive 4 + 12 V 7 8 High 1 7 Output 5 5 GND High Low Cabletype 30: (Attention: Both sides are female 9pin connectors ! (Alike 0modem cable). Length 1.8 m. UPS COMPUTER RECEIVE 3 SEND DTR GROUND 2 SEND 2 3 RECEIVE 4 5 4 5 DTR GROUND D-S UB 9 female D-S UB 9 female 2017-07-17 Cabletype 30_1: (for use with RWE Piller AR 50/25 AR30, AR40A or AS4) Attention: Both sides are female 9pin connectors ! (0-modem cable). Length 1.8 m Aline SAME cable like 30, but without DTR, 4---4 INFORM SD, PPS Serie (SAFER DSP) PIN CONFIGURATIONS RS232 serial communication port is connected to 9Pin D-SUB-male connector. Pin connections are as follows; GND - Pin 5 , TXD - Pin 3 , RXD - Pin 2 , The remaining pins do not have any connection. In the below diagram, computer serial communication connection via RS232 is shown as an example; UPS SIDE Pin No 2 3 5 PC SIDE Pin No 3 2 5 2017-07-17 Cabletype 30_Null: (Standard Null – Modem cable « Kabel_30Null » Both sides are female 9pin connectors ! (0-modem cable). Length 1.8 m Cabletype 31: old cable CS 110/ See archives Cabletype 32: old cable CS 110/ See archives Cabletype 33: old cable CS 110/ See archives Cabletype 34: SICON (SICON Standard Cable), Length 1.8m UPS 9pol/m PC 9pol/w 2-------------3 3-------------2 5-------------5 8------------ 7 Cabletype 35 :CHLORIDE (Null modem serial cable, for SILECTRON UPS EDP 70 & Synthesis, SICON LPX) Length 1.8m, UPS 9pol/m PC 9pol/w 2-------------3 3-------------2 5-------------5 2017-07-17 Cabletype 35/4: CHLORIDE (Null modem serial cable, for SILECTRON UPS EDP 70 & Synthesis), Extra length 4 m UPS 9pin/female PC 9pin/female 2---------------------------3 3---------------------------2 5---------------------------5 shielded ! Cabletype 36: old cable CS 110/ See archives Cabletype 37: old cable CS 110/ See archives Cabletype 38 : old cable CS 110/ See archives Cabletype 39 old cable CS 110/ See archives Cabletype 42: old cable CS 110 CS 110 SERCOM Agent - Optokoppler and Contact UPS (for use with Sicon Plurys LPX) 4x Resistors 3,3 KOhm, 1x Transistor BC 337 C Cabletype 43: old cable CS 110/ See archives Cabletype 44: old cable CS 110/ See archives Cabletype 45: (Serial cable 1:1 , for CHLORIDE/ACTIVE UPS), length 1.6 m Both sides are female 9pin connectors UPS 9pol/female PC 9pin/female 2---------------------------2 3---------------------------3 2017-07-17 5---------------------------5 Cabletype 46: old cable CS 110/ See archives Cabletype 47: old cable CS 110/See archives Cabletype 48: UNIBLOCK Spezialkabel für SEC PowerMon Multiplexer - Herr Piontek Softwareeinstellung "Cable 2" Pinlayout of SECs Multimon: Input UPS 9-pin DSUB male: Pin 1 Powerfail Pin 5 Battery Low Pin 2 Ground Output Computer 6-pin RJ11 female: Pin 2 Powerfail Pin 3 Ground Pin 4 Ground Pin 5 Battery Low Alle contacts are normally open – closing at alarm events. 2017-07-17 Cabletype 49: AROS SENTRY UPS (PILLER mod. 3-20) Kontaktbelegung REMOTE CONTROL AND SIGNALS In the front under the input terminal strip there are two tank connectors: Cannon 15-pin female marked REMOTE. Cannon 25-pin male marked RS232. REMOTE On the connector there are: Nr. 1 aux power 12Vdc 80mA(max) Nr. 3 Voltage free exchange contacts for alarms Nr. 2 Controls for turning off INVERTER and UPS. The pin arrangement of the connector is as follows (see figure opposite): A DISCHARGE END PREALARM B BATTERY DISCHARGING C BY-PASS/FAILURE The contact positions shown is without alarm (NORMAL OPERATION). The relay contacts can carry a current of 0.5A-42V. REMOTE COMMANDS Two commands are available as follows: BY-PASS with STOP INVERTER command. Connecting pin 8 to pin 15 (after at least 10 seconds). UPS LOCKUP command. Connecting pin 7 to pin 15 (after at least 10 seconds). 2017-07-17 BY-PASS with STOP INVERTER. Cabletype 49: Cable for Powerelite and other ENERGY 3000 compatible UPS via 15pin remote port. Normally closed. (Please use logic "cable 7" ) DB 15 male DB 9 female Cabletype 50: Cabletype CLOSED for RIELLO Power Dialog Dry-contacts (15Pin) and UNIX UPS 15pin/female Common Battery_ON PC UNIX 9pin/female 12 ----------------------------------------- 2 4 ----------------------------------------- 3 Cabletype 51: Mainpower serial cable, Mulitmatic/Effekta MH TEKNO UPS (See also cable 16) UPS 9pol/male Computer 9pin/female 9---------------------------2 6---------------------------3 5---------------------------4 7---------------------------5 8 1 6 7 2017-07-17 Cabletype 52: Cable for IMEL SWIFT UPS serial, 2400baud, Parity even, Databits 7, Stoppbits 1 1. Common GND 2. XMIT 3. RX 4. Emergency OFF 5. Reserved 6. RTS 7. GND 8. IBMSO - OUT 9. +8V UPS IMEL: 1 Common GND 2 XMIT 3 RX 6 RTS Computer: 5 Common GND 2 Receive 3 Send 7 RTS --- 1 Data Carrier Detect --- 4 Data Terminal Ready (Data Carrier Detect 1 connected with Data Terminal Ready 4). Cabletype 53: Optokoppler and Contact UPS / Windows, , Novell (for use with Riello HTX and Dialog 75 – 300 Series) Software Setting: Cable 2 3x Resistors 4.7KOhm Cabletype 54: Contact UPS / Windows, Novell (for use with GAMATRONIC MP 110 series) Software Setting: Cable 6 3x Resistors 4.7KOhm Cabletype 55: Contact UPS / Windows, Novell 2017-07-17 (for use with GAMATRONIC COMPACT series) Software Setting: Cable 2 3x Resistors 4.7Kohm Cabletype 56: Contact UPS / Windows, Novell (for use with GAMATRONIC MS series) Software Setting: Cable 6 3x Resistors 4.7KOhm Cabletype 57: UPSDIALER Standard ( normal Type cable 11, for use with ONLINE 700S ) Line / RS232 9pol/female UPS RS232 / Modem 9pol/male 2-----------------------------------2 3-----------------------------------3 5-----------------------------------5 SIC contact / UPS 9pol/male 4-----------------------------------4 2-----------------------------------6 2017-07-17 Cabletype 58: UPSDIALER Cable for Elsa Modem and Meta HF and HF Line HF&HF Line / RS232 9pol/male RS232 / Modem 9pol/male 2-----------------------------------3 3-----------------------------------2 5-----------------------------------5 HF&HF Line / contact 9pol/female 4-----------------------------------4 HF6HF Line / RS232 9pol/male 1 2 3 4 5 6 . . HF&HF Line / contact 9pol/female . . 3 4 5 . . RS232 / Modem 9pol/male 1 2 3 4 5 6 7 8 9 2017-07-17 Cabletype 58_2: UPSDIALER Fault tolerance, Cable for Meta HF and HF Line HF&HF Line / RS232 9pol/male RS232 / Modem 9pol/male 2-----------------------------------3 3-----------------------------------2 5-----------------------------------5 HF&HF Line / contact 9pol/female 4-----------------------------------7 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 On 8 Off X = discretionary (see Manual) Cabletype 59: old cable CS 110/ See archives Cabletype 60: old cable CS 110/ See archives Cabletype 61: USV cable for use with AS400 dry contact with Masterguard 40CP (built-in solution by IBM software, not UPSMAN) Attention: Remove pin 3 from the conector, this pin is not available in the AS400 port AS400 9pol/male USV-Type SIEMENS 40CP 9pin/male 2017-07-17 System ground On Utility failure Battery low Bypass active 5---------------------------4 8---------------------------4 3 6 7 9---------------------------2 7---------------------------5 6---------------------------1 8 9 common common cabel O.K +diode (UPS SD) - diode utility failure (Powerfailure) low battery bypass active 0V +12V Adapter from old AS400 UPS cable to new IBM I Series UPS interface: To connect the old AS 400 UPS cable to the new IBM I Series (buitl after 5/2005) you must purchase from IBM an adapter, IBM partnumber "1827". On 9406 iSeries model 520, the UPS connector is P1-T2. Serial port to UPS conversion cable: The new cable is a short “converter cable”. It physically attaches to one of the serial ports at the back of iSeries models 520/550/570. The 1827 converter cable is a 140mm (5.5 in.) serial port to UPS cable for iSeries models 520, 550 and 570. These models have no longer the J14 UPS connector. Instead, UPS communications to the iSeries is supported through a designated serial port via the 1827 converter cable. The serial port supports two models: RS232 serial port mode and UPS mode. Only one mode is supported at a time. The service processor will detect the presence of an UPS attached through serial port via the 1827 cable when the server is started and set the control hardware to condition the signals for the UPS. The mode cannot be changed unless the system is started again. The following figure shows the converter cable wiring: 2017-07-17 Cabletype 61 _1: For use with AS400 for dry contact, ONLINE PHXAS400I AS400 9pol/male USV-Type ONLINE PHX400I 9pin/male Attention: Remove pin 3 from the conector, this pin is not available in the AS400 port UPS inverter Alarm Remove this pin UPS summery alarm System ground Inverter on Bypass active Utility / Powerfailure Battery low 1 3 3 2---------------------------2 5---------------------------5 8---------------------------8 6---------------------------6 9---------------------------9 7 Remove this pin UPS summery alarm common Inverter on Bypass active Utility / Powerfailure Cabletype 62: USV cable for use with AS400 for dry contact (built-in solution with customer Rhone Poulenc, not UPSMAN) (For use with Piller AR 1, Riello Dialog) Attention: Remove pin 3 from the connector, this pin is not available in the AS400 port AS400 9pol/male System ground On Utility failure Battery low Bypass active USV 15pin/male 5---------------------------12 8---------------------------12 9---------------------------4 7---------------------------13 6 common common, cabel O.K utility failure (Powerfailure) low battery 2017-07-17 Cabletype 63: USV cable for use with Iwatec P5000, AEG Protect 1.0... 9pol/female 9pin/male 2---------------------------2 3---------------------------3 4---------------------------4 5---------------------------5 7---------------------------7 Cabletype 64: UPSDIALER Standard Siemens (normal Type cable 30, for use with A series including Sic - card ) Line / RS232 9pol/female UPS RS232 / Modem 9pol/male 3-----------------------------------3 2-----------------------------------2 5---------------------------------- 5 SIC contact / UPS 9pol/male 4-----------------------------------4 2-----------------------------------6 Cabletype 64_2: UPSDIALER Fault tolerance Siemens ( for use with A series including Sic - card ) Line / RS232 RS232 / UPS-Dialer 9pol/female UPS 9pol/male 3-----------------------------------3 2-----------------------------------2 5---------------------------------- 5 SIC contact / UPS 9pol/male 4-----------------------------------9 2-----------------------------------8 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 65: CS 110 SERCOM Agent (for use with Roton CONVEREX USV) 4x Resistors 3.3KOhm, 1x Transistor BC 337 C 2017-07-17 Cabletype 65_1: CS 111 GENEREX SNMP Agent (for use with Roton CONVEREX USV AS 400 port) Software Setting: Cable 2 Cabletype 66: USV cable for use UPSMAN Rs-232 with Riello Power Dialog . Do not use any other pins, only the pins 2,3 and 5 are allowed, not any other connection ! ( PWAEG ) 9pol/female 9pin/male Pin 2 ----------------- Pin 3 Pin 3 ----------------- Pin 2 Pin 5 ----------------- Pin 5 2017-07-17 Cabletype 67: For use with FSS20 Piller Uniblock Apostar Sign on PC and UPS side! PC USV 9pol/female 9pin/female Pin 5 ----------------- Pin 5 Pin 8 ----------------- Pin 6 Pin 3 ----------------- Pin 7 Pin 2 ----------------- Pin 8 Pin 7 ----------------- Pin 9 GND------------------- GND Cabletype 68: CS 111 Agent - Optokoppler and Contact UPS (for use with Powerbox PX 10) 4x Resistors 3,3 KOhm, 1x Transistor BC 337 C Cabletype 69: SENTR / PILLER AR 3 / Piller AR Power Plus/ 10-100 kVA (Aros Sentry)-UPSMAN RS23 or CS 111 / CS121 / CS141SNMP Adapter serial, length 1,80 m. 25pol/female UPS 9pin/female PC Pin 2 ------------------------------------------ Pin 2 Pin 3 ------------------------------------------ Pin 3 Pin 7 ------------------------------------------ Pin 5 2017-07-17 Cabletype 70: PK electronics US 9000 serial Pin out diagram (See cable 102 for dry contact, software settings cable 2) 5 1 9 6 The back of each 9000 series cabinet has a 9 pin port. The port is a female connection with the following connections. Pin Function Input or output 1 Not used 2 Rx: Data Receive Output 3 Tx: Data Transmit Input 4 DTR: 12volt supply Input 5 GND: Common Input 6 DSR: Battery Low Signal. Low active Output 7 Not used 8 DCD: AC Mains Failure. Output 9 Not used Cabletype 71: UPSDIALER Piller (Modem only Type cable 69, for use with Piller AR 3 / 10 or Aros Sentry) Line / RS232 25pol/female UPS RS232 / Modem 9pol/male Pin 2-----------------------------------Pin 2 Pin 3-----------------------------------Pin 3 Pin 7-----------------------------------Pin 5 SIC contact / UPS 15pol/male Pin 4-----------------------------------Pin 4 Pin 2-----------------------------------Pin 6 Cabletype 72: PILLER RS-232 Schnittstellenkarte StandardAdapter : 9pin to 25 pin (DB9 / DB25 Modem /Mouse Adapter) 9pin 25pin 1---------------------------8 2---------------------------3 3---------------------------2 4---------------------------20 5---------------------------7 6---------------------------6 7---------------------------4 2017-07-17 8---------------------------5 9---------------------------22 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Description Chassis ground Transmitted data Received data Request to send Clear to send Data set ready Signal ground Data carrier detect Reserved Reserved Unassigned nd DCD for 2 Channel nd CTS for 2 channel Pin 1 2 3 4 5 Description Carrier detect Receive data Transmit data Data terminal Signal ground 25 Pin connections Pin Description nd 14 Transmits for 2 channel 15 Transmit data clock nd 16 Receive for 2 channel 17 Receive data clock 18 Unassigned nd 19 RTS for 2 channel 20 Data terminal ready 21 Signal quality 22 Ring indicator 23 Data rate select 24 Transmit data clock 25 Unassigned 9 pin Connecctions Pin 6 7 8 9 Description Data set ready Request to send Clear to send Ring indicator Cabletype 73: USV cable for use UPSMAN Rs-232 with PILLER AR 1/6 AR1/10 AR50. ( PWAEG, FSS20 ) Do not use any other pins, only the pins 2,3 and 5 are allowed, not any other connection ! 9pol/female 9pin/female Pin 2 ----------------- Pin 3 Pin 3 ----------------- Pin 2 Pin 5 ----------------- Pin 5 Cabletype 74: UPSDIALER Standard ( normal Type 66 and 46, for use with Newave and Riello Power Dialog ) (for use with Newave EcoWave, PowerWave, PrimeWave) Do not use any other pins! ( PWAEG ) Line / RS232 9pol/female UPS RS232 / Modem 9pol/male 2-----------------------------------3 3-----------------------------------2 5-----------------------------------5 SIC contact / UPS 25pol/male 1-----------------------------------4 3-----------------------------------6 Cabletype 75: UPSDIALER Fault tolerance (for use with Newave and Riello Power Dialog ) 2017-07-17 (for use with Newave EcoWave, PowerWave, PrimeWave) Do not use any other pins! ( PWAEG ) Line / RS232 9pol/female UPS RS232 / Modem 9pol/male 2-----------------------------------3 3-----------------------------------2 5-----------------------------------5 SIC contact / UPS 25pol/male 1-----------------------------------9 3-----------------------------------8 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 76: ASTRID Starlet Halley Hyperion /JOVYATLAS Jovystar Delta, Mini, Mega, Mono RS-232 - “Kabel Y0002400” USV-System Computer Funktion (an der Computerschnittstelle) 5 5 4 4 3 3 2 2 1 1 SUB-D9 (Buchse) SUB-D9 (Buchse) 9 9 8 8 7 7 6 6 1 : DCD 2 : RXD 3 : TXD 4 : DTR 5 : Ground 6 : DSR 7 : RTS 8 : CTS Use a 1to1 cable with JOVYATLAS Jovystar Plus, Pro, Industrie, Ocean! Cabletype 77: UPSDIALER Fault tolerance (Riello Dialog Plus und Piller AR3/1) 2017-07-17 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 78: (for use as CS111 configuration cable ERREPI_D OP-series) ! Line / RS232 9pol/male UPS RS232 / Modem 9pol/female 1-----------------------------------3 2-----------------------------------2 5-----------------------------------5 Cabletype 79: (for use with Effekta MI series) UPS COMPUTER TX 9 RX DTR 6 1 GND D-SUB 9 male 7 2 RX 3 TX 4 5 DTR GND D-SUB 9 female 7 RTS Cabletype 80: UPSDIALER Fault tolerance Piller (3m length) (Without Multiplexer See cable 98) ( for use with AR3 Sentry and XR5 Analog multiplexer) 2017-07-17 UPS / RS232 25pol/female RS232 / UPS-Dialer UPS 9pol/male 2 3 7 3 2 5 8 Multiplexer 9pol /mal 1 2 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 On 7 Off 8 On X = discretionary (see Manual) Cabletype 81: UPSDIALER Fault tolerance Errepi OP UPS / RS232 9pol/female 1 2 4 3 5 RS232 / UPS-Dialer UPS 9pol/male ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 2 3 5 8 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 82: UPSDIALER Fault tolerance HTSER for Piller AR 1-3, Riello Dialog 2017-07-17 Line / RS232 9pol/male RS232 / UPS-Dialer UPS 9pol/male 1-----------------------------------1 2-----------------------------------2 3-----------------------------------3 4-----------------------------------4 6-----------------------------------6 7-----------------------------------7 8-----------------------------------9 9-----------------------------------5 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 83: UPSDIALER Fault tolerance with Multiplexer for ERREPI OP (On Power) UPS-Dialer UPS ERREPI OP D-SUB 9 male D-SUB 9 female D-SUB 9 male D-SUB 9 male 3 2 3 1 2 3 2 2 5 5 5 4 Multi 4 - 232 / Archer 8 GND 3 5 GND Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) 2017-07-17 Cabletype 84: UPSDIALER Fault tolerance, Cable for PK Electronics US9000 PK US9000 / RS232 9pol/male RS232 / UPSDialer 9pol/male 2-----------------------------------3 3-----------------------------------2 4-----------------------------------9 5-----------------------------------5 8-----------------------------------6 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 On 7 On 8 Off X = discretionary (see Manual) Cabletype 85: Adapter SUN ULTRA 2 - 25-pin female SUN to 9-pin D-Sub female (Rs-232) This adapter is designed to change the SUN 25 female serial interface to a 9 pin standard DSub 9 interface. The orignal UPS 9 Pin cable must be connected after this adapter. For UPS original cable layout see technical information of your UPS. Original UPS cable Adapter UPS Cable side Adapter SUN 25pin side 9pin/male SUN 25pin/male 1-----------------------------------8 2-----------------------------------3 3-----------------------------------2 4-----------------------------------20 5-----------------------------------7 6-----------------------------------6 7-----------------------------------4 8-----------------------------------5 9----------------------------------- 22 SUN 25 pin female 2017-07-17 Cabletype 86: INFORM UPS 9-pin D-Sub female (Rs-232) All of the dry - contacts are normally open at normal status. If one of the alarms ( bypass in progress, battery under voltage , AC failure) occures releated contacts will be closed.(Contacts named A,B,C) and the summary alarm contact will be closed. The sixth pin of the female dsub connector is an input pin. If logic high (+5VDC between pins 6-7) voltage is applied to this pin , UPS will go to remote shutdown mode. 2017-07-17 UPS FEMALE DSUB 9CONN 4 A B C D 8 SUMMARY ALARM CONTACT 1 BYPASS IN PROGRESS CONTACT 5 BATTERY UNDER VOLTAGE CONTACT 2 AC FAILURE CONTACT 6 UPS REMOTE SHUTDOWN INPUT 7 GND MALE DSUB 9 CONN 3 TX 2 RX 5 GND 2017-07-17 Cabletype 87: UPSDIALER Fault tolerance, Cable for INFORM UPS models Line / RS232 RS232 / UPS-Dialer 9pol/female UPS 9pol/male 3-----------------------------------3 2-----------------------------------2 5---------------------------------- 5 SIC contact / UPS 9pol/male 4-----------------------------------9 1-----------------------------------8 2----5----8----Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) Cabletype 88: UPSDIALER Fault tolerance Multimatic ( for use with Aline Modular) UPS / RS232 9pol/male 2 3 5 RS232 / UPS-Dialer 9pol/male 3 2 5 8 Dry contact 9pol /femal 3 5 1 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On X = discretionary (see Manual) 2017-07-17 Cabletype 89: UPSDIALER Fault tolerance S 4000 Standard Panel ( for use with Best 4000, Borri 4000, cable length 5m contact cable 0,5m) Dialer / RS232 9pol/male RS232 / UPS-S4000 9pol/male 2 4 5 8 1 2 3 Dry contact Open contact cable Panel M2, pin 3 (Braun) Panel M2, pin 1 (Yellow) Dip-Switch Settings: 1X 2X 3X 4X 5X 6 off 7 off 8 on X = discretionary (see Manual) Cable type 90: UPSDIALER Fault tolerance PTX 3 Powertronix ( for use with Powertronix PTX3 ) Dialer / RS232 DB9pol/male 2 4 5 8 9 UPS-PTX 3 / RS232 DB25pol/male 2 3 7 UPS-PTX 3 / Dry contacts (Splitting length 40cm) DB9pole/male 4 = Common 6 = General Alarm (4 & 6 close together when any alarm comes active) Dip-Switch Settings: 1X 2X 3X 4X 5X 6 off 7 off 8 on X = discretionary (see Manual) 2017-07-17 Cabletype 91: For use with ROTON OPAL, XANTO X2, AEC UPS types, Length 2.5m UPS 9pol/male PC 9pol/female 6----------------------------2 9----------------------------3 7----------------------------5 Schirm einseitig aufgelegt, auf der PC Seite! Electromagnetic shielding connected only at PC-femail! Cabletype 92 : (modified cable 6,7 for UPS model PX 40 Powerbox and AEG SVS Protect 1 with software settings cable 8) – Caution ! If this cable is used, the CS121/CS141 or PC must not be switched OFF. This could activate the emergency UPS off signal !) Cabletype 92_1 : (modified cable 6,7 for UPS model PX 40 Powerbox and AEG SVS Protect 1 with software settings cable 8, no UPS off!) 2017-07-17 Cabletype 93: (Modified cable 6 for UPS model PTX of Powerbox, software settings cable 6) Cabletype 94: (for use with S4000 SFP / UPS Dialer) 2017-07-17 Cabletype 95: (for use with S4000 SFP with Multiplexer and UPS Dialer) 2017-07-17 Modemport Cabletype 96: (for use with Best 3100, Borri ET II) Modemport Cabletype 97: (for use with Liebert Hiross UPSall UPS, cable type 2) Belegung an der USV Seite, Steckerbuchse DB9: Pin 1 2 3 4 5 6 7 8 Beschreibung Batterie fast leer (N.O) T.B.D T.B.D N.C Common N.C Batterie fast leer (N.O) Stromausfall (N.O) 2017-07-17 9 Stromausfall (N.O) Cabletype 98: UPSDIALER Fault tolerance Piller (3m length) ( for use with AR3 Sentry) UPS / RS232 25pol/female 2 3 7 RS232 / UPS-Dialer UPS 9pol/male 3 2 5 8 Contact / UPS AR3 15pol /male 3 6 12 4 10 13 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 Off 8 On Modemport Cable 99: for use with Microdowell Bbox and Hibox UPS (sofware settings cable 2), all non-UNIX INTEL based OS, also for LINUX systems. 2017-07-17 Cable 100(X28): UNIX OPENED / ROPEN, ( for Microdowell Bbox and HiBox UPS and non-INTEL systems, software settings R-OPEN, Typ O) UPS 9pol/male UNIX computer 9pin/female PF 8---------------------------3 Common 4---------------------------2 Cable 101: Configuration cable for NEWAVE CONCEPTPOWER CS111 slot SNMP Adapter (Do not connect the shield on both side!) PC - 9 pin female UPS - 9 pin male pin 2 pin 7 pin 3 pin 8 pin 5 pin 5 Cable 102: PK dry contact cable for software setting cable 2. (Use with US9000, see also cable 70). Tested with NT 24.09.2001 UPS - 9 pin male PC - 9 pin female pin 8 (Mains Failure +12V) pin 1 pin 6 (Battery low +12V) pin 8 pin 5 (GND: Ground) pin 5 2017-07-17 Cabletyp 103: (For use with ASC USV OPAL) Cabletype 104: UPSDIALER Fault tolerance NEWAVE (3m length) ( for use with ConceptPower) UPSDialer / RS232 9 pol/male 2 3 5 6 7 RS232 / UPS-Dialer UPS 9pol/male 3 2 5 Contact / UPS 25 pol /male 1 10 3 12 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 On 8 Off 2017-07-17 Cabletype 105: UPSDIALER Fault tolerance ONLINE ( for use with ONLINE XANTO including PHXNOV-I dry contact card.) UPSDialer / RS232 9 pol/male 2 3 5 6 7 RS232 / UPS UPS 9pol/male 2 3 5 PHXNOV-I dry contact card / UPS 9 pol /male 2 4 Dip-Switch Settings: 1X 2X 3X 4X 5X 6 Off 7 On 8 Off Modemport Cable 106 for use with dry contact on NEWAVE Primewave, Powerwave, Ecowave or Conceptpower UPS 2017-07-17 Cabletype 107: PILLER Apostar AR 30A/6, length 1.8m (For use with EXIDE protocol) PC SUB- D 9pol/femail USV SUB- D25pol/mail 2----------------------------------------------3 3----------------------------------------------2 5----------------------------------------------7 Cabletype 108: PILLER AS 20 - AS 400, UB 150 - 1100, length 1.8m (For use with FSS20 protocol) PC SUB- D 9pol/femail USV SUB- D 9pol/femail 2----------------------------------------------8 3----------------------------------------------7 5----------------------------------------------5 |--------6 |--------9 Cabletype 109: not defined Cabletype 110: PILLER AR-50 without panel using cable 8 logic, length 5m 2017-07-17 Cabletype 111: ABB PX3 Serie 6 for UPS Dialer FT UPS-Dialer FT – ABB PX3 Serie 6 DIP-Schalter Einstellungen DIP-6 DIP-7 DIP-8 OFF ON OFF DIP-Schalter Einstellungen DIP-6 DIP-7 DIP-8 ON ON OFF 2017-07-17 Cabletype 112: Schneider TSX SCY CN 6030 Modbus device – CS121/CS141 MODBUS adapter Cabletype 113: CS121/CS141 SNMP adapter to UPSDIALER Pin COM2 Mini-DIN 8 pol (male), CS121 SUB-D 9 male connector 1 PIN 3 PIN 2 PIN 1 6 2 3 shield 7 8 4 9 5 Cabletype 114: FUJI cable type PCA05955-0692 2017-07-17 Cable 115 (Tempman) CS121/COM2 to Tempman Cable 116 USV (ABB standard, Serie SitePro Serie 6, for serie 4 same cable but femail on UPS) Sub D9 – Stecker 135 Grad auf Sub D 9 Buchse, Verbindung Pins: 2-2, 3-3. 5-5 2017-07-17 Cabletype 117 : MCB Srl Italy, modified Cable 7 with Bypass) Cabletype 118 : IXTECH Gmbh – Guardian on Board UPS – UPSMAN Cablelogic 2 Stereo Plug 3.5 mm DB 9 female Tip (black) 1 DCD 4 DTR Mid (brown) 8 CTS GND (red) 3 (Tx) 10 Kohm = Cabletype 119 : MCU Kabel – UPSMAN Cablelogic 2, SNMP Adapter CS121/CS141 <-> MVU 2000 (Length 2 Meter, cable end X1… prepare with cabel end sleeve and sign) 9 Pol / femail DB9 DTR 4 DSR (br) 6 No urgent alarm X1/9 (K2/X11/1) 2017-07-17 Battery fault CTS (pink) 8 X1/12 (K3/X12/1) O.K RI (white) 9 X1/8 (K1/X10/3) Urgent alarm DCD (grey) 1 X1/6 (K1/X10/1) Ground GND (blue) 5 X1/7 (K1/X10/2) Resistance: 4,7K Ohm = X1/7 X1/10 X1/13 Cabletype 120 : Cable for HP UNIX MUX Port and UPS (Masterguard) USV 9polig HPUX 25polig 5 -----> 7 2 -----> 3 3 -----> 2 7 4 8 5 9 22 4 -\ 20 \ 6 \-> 6 1 8 ---GND----- (Signalmasse) ---RxD----. (Recieve Data - Empfangsdaten | von Gegenstelle über DCE zum DTE) ---TxD----' (Transmit Data - Sendedaten vom DTE über DCE zur Gegenstelle) ---RTS----. (Reqest To Send - Empfangsbereitschaft | des DTE) ---CTS----o (Clear To Send - Sendebereitschaft | des DCE) ---RING---' (DCE hat Ruf erkannt) ---DTR----. (Data Terminal Ready - DTE ist prinzipiell | bereit, d.h. Port aktiviert) ---DSR----o (Data Set Ready - DCE ist prinzipiell | bereit, d.h. eingeschaltet) ---DCD----' (Data Carrier Detect, man ist verbunden) Cabletype 121 : Cable for ROCOMA INVERTER (dry –contacts) and CS121/UPSMAN, software settings “cable 11”) 2017-07-17 Overtemperature = Pin 3 + Pin 4 + Pin 5 connected to Pin 9 Bypass = Pin 1 + Pin 4 + Pin 5 connected to Pin 9 Screenshot CS121 using ROCOMA cable 11, Pin 4+5 connected to Pin 9 - Status OK: 2017-07-17 Screenshot CS121 using ROCOMA cable 11, Pin 5 connected to Pin 9 – Status Emergency line failure, DC line present: Screenshot CS121 using ROCOMA cable 11, Pin 4 connected to Pin 9 – Status DC line failed, Emergency line present : 2017-07-17 Screenshot CS121 using ROCOMA cable 11, Pin 3 + Pin 4 + Pin 5 connected to Pin 9 – Status Overtemperature Screenshot CS121 using ROCOMA cable 11, Pin 1 + Pin 4 + Pin 5 connected to Pin 9 – Status On Bypass: 2017-07-17 Cabletype 122: Fiskas PS20 USV, length 1.8m (For use with FSS20 protocol) PC SUB- D 9pol/femail USV SUB- D25pol/mail 3----------------------------------------------1 2----------------------------------------------2 5----------------------------------------------4 Cabletype 123: INORM (R & P), length 1.8m (For use with Pyramid Plus PPS series) PC SUB- D 9pol/femail USV SUB- D25pol/mail 2---------------------------------------------6 5---------------------------------------------8 3---------------------------------------------9 Cabletype 124: For use with ROTON OPAL, XANTO X2, AEC T2000 and T2003 after Serialnumber 0405xxU, Length 2.5m UPS 9pol/male PC 9pol/female 6----------------------------3 9----------------------------2 7----------------------------5 Schirm einseitig aufgelegt, auf der PC Seite! Electromagnetic shielding connected only at PC-female! 2017-07-17 Cabletype 125: Ups interface of ERREPI (Modell 1990) HT PIN-Belegung des USV-Rechner-Signalausgangs (HT 1600) Stecker DB15 (Male) 9 2 SHUT-DOWN 1 C. C = UPS OK 7 C. C. = BY-PASS ON 6 C. C. = BATTERY ON 14 C. C. = BATTERY WORKING 15 COMMON 13 PIN 1: Shut-Down Abschalten der USV sobald Datei im Server gesichert ist. PIN 7: UPS OK Inverter = Normalbetrieb PIN 6: BY-Pass ON Bypass-Betrieb bei Überlast oder Inverter defekt. PIN 14: Battery Low Batteriekapazität geht zu Ende. Restlaufzeit ca. 2 Minuten. PIN 15: Battery working Netzausfall / Batteriebetrieb. 2017-07-17 Cabletype 126: (modified Cable 7_1 with Bypass) Software driver cable 7. Cable for SICON SOCCOMEC Plurys HP device A dry contact. For UPS with dry-contacts relais and bypass alarm. DB 9 male DB 9 female Cabletype 127: (modified Cable 7_1 with Bypass) Software driver cable 7. Cable for SICON SOCOMEC DIGYS dry contacdt interface Terminal. Connection via terminal block at Socomec UPS. Terminal Block - Upside: XC1/XC2 is side DB 9 female (PC UPSMAN or CS121/CS141) 2017-07-17 Cabletype 128: (EFFKTA Cable M3502 with BACS Alarm support) At RI signal this cable triggers the UPSMAN software and CS121/CS141 an alarm signal for defekt batteries. Cabletype 129: USV cable for use AEG Protect 2.33, 3.33 9pol/female 9pin/male 2---------------------------2 3---------------------------3 5---------------------------5 Cabletype 130: (modified Cable 8_I for APC SILCON 480Kw 400 V UPS dry contact interface X005 25 Pin Sub D female. Contacts are normally open. Use logic cable "8" or “7”. DB 25 male DB 9 female 2017-07-17 Cabletype 131: Daisy chain cable from SM_T_H Sensor to SM_PLUS Sensor. Use a 1:1 cable for the connection between SM_PLUS and the SENSORMANAGER. Cabletype 132: Communication of dry contact relais to a UPS with opto isolated contacts. Cabletype 133: Piller open 1,8m open 0,5qmm -cable RS232 femail / open PIN 2, 3, 5 and Ground only. SNMP Adapter SUB- D 9pol/femail open pin / sigened with 2,3,5 GND / Wire termination 10cm open 2----------------------------------------------2 3----------------------------------------------3 5----------------------------------------------5 Shield---------------------------------------S 2017-07-17 Cabletype 134: SiteMan_V/VI and GSM RS232 cable 1:1 Cable with Mini Din 8-pol to RS232, length 30 cm. “1x Mini Din 8-pol. connector, male”, “1x 9-pol. Rs232 connector, male” Mini Din 8 male ---> DSub9 male PIN: PIN: 1------------------------------->1 2------------------------------->2 3------------------------------->3 4------------------------------->4 5------------------------------->6 6------------------------------->7 7------------------------------->8 8------------------------------->9 Shield------------------------>5 financial statements comply with a PC / CS121- COM1 Damit entspricht der Anschluss dann einer PC/CS121-COM1 Schnittstelle Cabletype GSM_A: Adapter between CS121_CONFIGCABLE an TCi35 Serial Port 2017-07-17 Contact Cable for Eaton STS Transfer Switch Cable for GPRS/UMTS Router Cabletype BACS Bus Converter III / RS232: RS232 cable between PC and BACS Busconverter III 2017-07-17 MITSUBISHI UPS cable : 2017-07-17 2017-07-17