Transcript
genesis
Standard Features • Energy Star® Qualified
DH5000T High Temperature Hood-type Dishwashing Machine
• New Exclusive Built-in booster configured for both 40° and 70° Rise • Field convertible from straight to corner operation • Dual NSF listed as both a dishwasher and potwasher • Rinse Sentry – ensures 180°F final rinse • Auto start – starts unit when hood is closed • Single point electrical connection • High efficiency 2 HP pump • Up to 55 racks per hour • Self draining pump • Automatic tank fill • Detergent/chemical connections • Interchangeable upper and lower spray arm • Automatic drain valve – drains wash tank when power is off • Vent fan control • Bottom mounted digital controls • PRV (Pressure Reducing Valve) • Sloped hood keeps hot vapors away from operator • Standard and Heavy Duty wash cycles • 4 selectable cycles • 27" [686mm]– extended clearance
Options & Accessories :: Drain Water Tempering Kit :: Direct Vent Option with fan :: Ventless/Heat Recovery/Condensate Removal option :: Door interlock – locks door closed during the vent fan cycle :: Hot water coil with gas booster :: Single phase option :: Racks :: Peg :: Flat :: Sheet Pan rack
specifier statement Specified unit will be Champion model Genesis, DH5000T high temperature hood-type dishwashing machine. Features sloped hood, electronic controls, Rinse Sentry, Auto start, interchangeable stainless steel wash and rinse arms, up to 55 racks/hr., .85 US gals [3.37 liters, 0.74 imp. gals]/rack. 1 year parts and labor warranty. Champion Industries, Inc. 3765 Champion Blvd., Winston-Salem, NC 27105 Tel: 336/661-1556 Fax: 336/661-1979 2674 N. Service Road Jordan Station, Ontario, Canada L0R 1S0 Tel: 800/263-5798 Fax: 905/562-4618 www.championindustries.com
(1M) 12/12 Printed in U.S.A.
Pro/Line Marketing,Inc.
Genesis Hood-type
Project Item No. Quantity
8" [203]
20-1/8" [511]
2-5/8" [67]
2-5/8" [67]
20-1/8" [511]
25-1/4" [641] Between Tables
Genesis 2-5/8"
[67] DH5000T High Temperature 20-1/8" 1-7/8" [511] Hood-type Dishwashing Machine [48]
20-1/8" [511]
5-1/8" [129] Min.
Min.
Shipping weight crated: 300 lbs.
Dimensions shown in inches and [mm] 8" [203]
29-3/4" [757]
Rinse Aid Location
29-3/4" [757]
7-3/4" [197]
30" [762]
11-3/8" [290][32] Roll 1-1/2" 3-1/2" [89] 6" 21-3/8" [152] [543]
6" [152]
Front View
40-3/4" Chemical [1034] Probe 33-3/4" [857] Location
5" [126]
11-3/8" [290]
3-1/2" [89] 17" [432]
27" 2-5/8" [686] [67] Clearance 20-1/8" 70-1/8" [511] Chemical [1780] Injection Location
69" 70-1/8" [1754][1780]
Chemical Injection Location
7-3/4" [197]
7-1/4" [184] 17" [432] 19-5/8" [500] 31" [787] 26-1/8" [663]
27" 90-3/4" [686] [2305] Clearance Hood Up
69" [1754]
40-3/4" 33-3/4" [1034] [857]
5" [126]
29-3/4" 20-1/8"[757] [511]
Rinse Aid 90-3/4"Location [2305] Hood Up
27" [686] Clearance 70-1/8" [1780]
1-1/8" [29]
8" [203]
20-1/8" 25-1/4" [641] [511] Between Tables
20-1/8" [511]
Genesis Hood-type
3/4" 05] d Up
8" [203]
Chemical Probe Location 29-3/4" [757] 3-1/2" [89]
31" [787] Rinse Aid Location
19-5/8" [500]
19-5/8" [500]
Side View 90-3/4" [2305] Hood Up
26-1/8" [663]
27" [686] Clearance
26-1/8" [663]
7
69" [1754]
Typical Table Construction
7-3/4" 1-7/8" [197] [48] Min.
30" [762] 1-1/2" [32] Roll
1-1/8" [29]
8" [203]
7-1/4" [184]
Utilities Electrical
2
Hot Water
3
Drain
6" [152]
20-1/8" [511]
21-3/8" [543]
1
11-3/8" [290]
5-1/8" [129] Min.
5" [126]
17" [432] 31" [787]
Plan View
2-5/8" [67] 20-1/8" [511]
Machine Connection (See Electrical Box) 3/4" NPT Hot Water 110° - 140°F/43° - 60°C 20-22 PSI Flow pressure
Warning: Plumbing, electrical connections 29-3/4" should be made by qualified[757] personnel who will observe all the applicable plumbing, sanitary and safety codes and the National Electrical Code.
2" [51mm] OD Connection 15 GPM max flow
[197]
11-3/8" [290]
90-3/4" Minimum Supply [2305] Hood UpCircuit Ampacity
Rated Amps 35-39 69" 21-24 [1754] 11 40-3/4"
33-3/4" [1034] [857]
45 30 20
Voltage
460-480/60/3
25-1/4" [641] Between Tables
3-1/2" [89]
SPECIFICATIONS Capacities
19-5/8" [500] 26-1/8" [663]
Racks per hr. Wash tank (gal.) [liters/imp gal.]
Rated Amps 71-81 42-48 20-21
Minimum Supply 3-1/2" Circuit Ampacity [89] 100 60 30
30"
[762] Motor horsepower Water consumption1-1/2" [32] Roll
2 HP 7-1/4" [184]
Gal. per hr. (max. use) 21-3/8" 47 [liters/imp1-1/8" gal.] [543] [177/39] [29] Gal. per rack (dishwasher) 0.85 [liters/imp gal.] [3.2/0.7] Gal. per rack (pot & pan washer) 1.18 [liters/imp gal.] [4.5/0.98]
Maximum Wash 150/66 27" Overcurrent [686] Rinse 180/82 Protective Device Clearance 45 70-1/8" Heating [1780] Chemical 30 Injection Tank heat, electric 5.2 kW Location 20 Electric Booster 7.5-10 kW Maximum Overcurrent Protective Device 100 19-5/8" [500] 60 26-1/8" 30 [663]
Wash
Dishwasher Mode
Rinse Sanitary Dwell Total cycle
35 10 15 60
Chemical Probe Location
Pot/Pan Mode
65 214 334 10 15 15 15 11 11 90 240 360
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Blvd., NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com Champion Industries, Inc. www.championindustries.com/canada •
[email protected] 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Pro/Line Marketing,Inc.
Rinse A Locat
55 9.5 [36/7.9]
Time cycle in seconds
5" Electric Heat, 40°/70° Rise Booster [126]
17" 6" [432] [152]208-240/60/1 208-240/60/3 31" [787]
Corner Configuration
Temperature °F/°C
Electric Heat, No Booster Rinse Aid Location
Voltage 208-240/60/1 208-240/60/3 7-3/4"460-480/60/3
40-3/4" 33-3/4" [1034] [857]
11-3/8" [290]
Min. 8" [203]
8" [203]
20-1/8" [511]
20-1/8" [511]
DH5000T High Temperature Hood-type Dishwashing Machine
Direct Vent Option [60]
30" [762]
Rinse Aid Location
7-3/4" [197]
[184] 1-1/2" [32] Roll 1-1/2" 7-1/4" [32] Roll 21-3/8" [543] 1-1/8" [29]
8" ]
2-3/8" [60]
Rinse Aid Location
90-3/4" [2305] Hood Up 69" [1754]
30" [762] 7-1/4" [184] 11-3/8" [290]
21-3/8" [543]
11-3/8" [290] 8-3/4" [221]
6" [152]
7-3/4" [197] 5" [126]
8-3/4" [221]17" 6" [432] [152] 31" [787]
1-7/8" [48] Min.
Chemical Injection Location
1
Electrical
2
Hot Water
3
e Aid tion
4
3/4" NPT Hot Water 110° - 140°F/43° - 60°C 20-22 PSI Flow pressure
Drain
2" [51mm] OD Connection 15 GPM max flow 90-3/4"
Exhaust - Direct Vent Only [2305] Hood Up
250 CFM Fan 4" [102mm] Round69" Duct [1754]
7-3/4" [197] 5" [126]
29-3/4" [757]
27" 93-1/4"27" 93-1/4" [686] [686] Clearance [2369] Clearance [2369]
43-5/8" [1107]
43-5/8" [1107]
Side View
31" [787]
3-1/2" [89] 19-5/8" [500]
19-5/8" Front [500]
26-1/8" [663]
13" [300]
View
26-1/8" [663]
SPECIFICATIONS 5-1/8" [129] Min.
20-1/8" [511]
Capacities
Racks per hr. Wash tank (gal.) [liters/imp gal.]
48 9.5 [36/7.9]
Motor horsepower 25-1/4" [641] Water consumption Between
2 HP
2-5/8" [67]
Plan View 37" [938]
Machine Connection (See Electrical Box)
29-3/4" [757]
3-1/2" [89]
17" [432]
2-1/8" [511]
Utilities
37" [938]
69" [1754]
40-3/4" 40-3/4" 33-3/4" [1034] 33-3/4" [1034] [857] [857] 5" [126]
Chemical Probe Location
For standard machine dimensions see DH5000T drawing
37" [938]
90-3/4" [2305] Hood Up
8" [203]
/4" 69]
2-3/8" [60]
2-5/8" [67]
Dimensions shown in inches and [mm]
Allows unit to vent directly to the outside. No vent hood required. 2-3/8"
25-1/4" [641] Between Tables
2-5/8" [67] 2-1/8" [511]
2-1/8" [511]
Shipping weight crated: 350 lbs.
5-1/8" [129] Min.
29-3/4" connections should be Warning: Plumbing, electrical [757] made by qualified personnel who will observe all the applicable plumbing, sanitary and safety codes and the National Electrical Code.
Electric 40°/70° Rise Booster Min. Min. Supply Ckt. Overcurrent Rated Conductor Protective Voltage Amps Ampacity Device 27" 100 93-1/4" 208-240/60/1 71-81 100 [686] 208-240/60/3 42-48 60 Clearance 60 [2369] 460-480/60/3 20-21 30 30
Gal. per hr. (max.Tables use) 41 [liters/imp gal.] [155/34] Gal. per rack (dishwasher) 0.85 [liters/imp gal.] [3.2/0.7] Gal. per rack (pot & pan washer) 1.18 [liters/imp gal.] [4.5/0.98]
Temperature °F/°C
Wash 150/66 Rinse 180/82
Heating
Tank heat, electric Electric Booster
5.2 kW 7.5-10 kW
Time cycle in seconds Wash
Dishwasher Mode
Rinse Sanitary Dwell Vent Fan Total cycle
35 65 10 10 15 15 10 10 70 100
Pot/Pan Mode
214 334 15 15 11 11 10 10 250 370
Chemical Injection
Location ‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. 40-3/4" Due to an ongoing value analysis program43-5/8" at Champion, specifications contained in this catalog are subject to change without notice. Chemical [1107] 33-3/4" [1034] Probe Champion Industries, Inc., 3765 Champion Blvd., NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com [857] Location Champion Industries, Inc. www.championindustries.com/canada •
[email protected] 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Pro/Line Marketing,Inc.
Genesis Hood-type
Genesis
5-1/8" [129] Min.
Min.
Genesis Hood-type
Genesis DH5000T High Temperature Hood-type Dishwashing Machine Shipping weight crated: 350 lbs.
CKS
[938]
ventless/heat recovery/condensate removal Option
29-3/4" [757]
Removes heat and water vapor at the end of the cycle while recovering the normally exhausted heat and transferring it to the booster. 37" No vent hood required. [938] 2-3/8" [60]
29-3/4" [757]
2
2-3/8" [60]
2
2
27" [686] Clearance
2
30" [762] 30" [762] 1-1/2" [32] Roll
7-1/4" [184]
1-1/2" [32] Roll
21-3/8" [543] 1-1/8" [29]
1-1/8" [29]
90-3/4" [2305] Hood Up
RINSE AID LOCATION
74" [1880] 74" [1880]
40" 69" 33" [1034] [1754] [857]
17" [432]
6"
18" [152] [221] 6" 3 1 [152] 3
5-1/8" [129] Min.
Chemical Injection Location
43-5/8" [1107]
5-1/8" [129] Min.
For standard machine dimensions see 19-5/8" 3 DH5000 drawing [500]
Utilities
26-1/8" [663]
1
Electrical
2
Cold Water
3
Drain
Machine Connection (See Electrical Box) 3/4” NPT Cold Water 70°F [21°C] 40 - 45 PSI (machine operates at 20 - 22) 2" [51mm] OD Machine Drain Connection 15 GPM max flow
19-5/8" [500] 26-1/8"
[663] Front View
SPECIFICATIONS
Capacities
Racks per hr. Wash tank (gal.) [liters/imp gal.]
37 9.5 [36/7.9]
Chemical Injection Motor horsepower Location Water consumption
Chemical Probe Location
3-1/2" [89]
3
2-5/8" [67] 1
3 19-5/8" [500] 26-1/8" [663]
8" [203] 20-1/8" [511]
3-1/2" [89]
3-1/2" [89]
Side View
17" 31" [432] [787] 3 31" [787]
INSIDE TRACKS
91-3/4" [2331]
1
3
1-7/8" [48] Min. 27" [686] Clearance
1
20-1/8" [511]
2-5/8" [67]
INSIDE TRACKS
Plan View Warning: Plumbing, electrical connections should be made by qualified personnel who will observe all the applicable plumbing, sanitary and safety codes and the National Electrical Code.
Electric 70° Rise Booster Minimum Maximum Supply Ckt. Overcurrent Rated Conductor Protective Voltage Amps Ampacity Device 208-240/60/1 83-95 125 125 208-240/60/3 49-56 60 60 460-480/60/3 23-24 30 30
2 HP
Chemical Probe Gal. per hr. (max. use) 32 Location [liters/imp gal.] [121/26.6] Gal. per rack (dishwasher) 0.85 [liters/imp gal.] [3.2/0.7] Gal. per rack (pot & pan washer) 1.18 [liters/imp gal.] [4.5/0.98]
Temperature °F
Wash 150/66 Rinse 180/82
Heating
Tank heat, electric Electric Booster
5.2 kW 10 kW
Time cycle in seconds
Dishwasher Mode
Wash Rinse Sanitary Dwell Vent Fan Total cycle
35 10 15 30 90
65 10 15 30 120
Pot/Pan Mode
214 15 11 30 270
‘USGBC’ and related logo is a trademark owned by the U.S. Green Building Council and is used by permission. Due to an ongoing value analysis program at Champion, specifications contained in this catalog are subject to change without notice. Champion Industries, Inc., 3765 Champion Blvd., NC 27105 • 336/661-1556 • Fax: 336/661-1979 • www.championindustries.com Champion Industries, Inc. www.championindustries.com/canada •
[email protected] 2674 N. Service Road, Jordan Station, Ontario, Canada L0R 1S0 • 800/263-5798 • Fax: 905/562-4618
Pro/Line Marketing,Inc.
91-3 [233
8" [203]
20-1/8" [511]
43-5/8" [1107]
40" 33" [1034] [857]
5" 1 [126]
91-3/4" [2331]
43-5/8" [1107]
[2305] Hood Up
7-1/4" [184]
8" [221]
27" [686] Clearance
69" 90-3/4" [1754]
RINSE AID LOCATION
5" 1 [126]
37" [938] 21-3/8" [543] 29-3/4" [757]
4" ] Up
"
37" and [mm] Dimensions shown in inches
334 15 11 30 390