Transcript
The Genesis HyperMDC 200D is a metadata cluster designed for ease-of-use and quick deployment. IPMI Control
Dual Power Supplies
Enhanced Metadata Uptime Storage
Up to 1.3M IOPS and 5,500 MBps throughput
SAS 15K RPM HDDs
Dual Controller
Pre-installed HyperFS/SONG
SSD Mirrored Boot Drives
Enterprise-class File System Platform HyperFS integrates high-performance SAN, Scale-Out NAS and data protection under one global namespace.
Simplified Connectivity Plug-and-play with easy connectivity options that can be mixed and matched to support 8/16Gbit FC, 1/10/40Gbit SMB, NFS, and iSCSI
Fully Redundant Metadata Built for low latency, leveraging dual controller RAID, dual servers and bonded network and fabric
Genesis HyperMDC 200D
Data Flow for SAN and Scale-Out NAS using HyperFS
Data Flow HyperFS Client Protocol
Open Protocols
DATA
SMB/NFS/HTTP(s)/FTP(s)
Scale-Out NAS Gateways
Metadata Controller Volumes
DATA
DATA up to PBs
Drive Letter
SONG Re-export
META up to 4TB
META
Connect to Server
Map Network Drive
TA
ME
Mount Point
Mount Point
META SAN/BLOCK
LAN/FILE
Genesis IAP base server system and controller features Chassis Scale Logic, Inc.
RoHS compliant 1U Steel and Aluminum Alloy enclosure with rack mount kit, dual FRU power supplies and fan assemblies and 6Gbit SAS Drive Backplane Power on/off switch; System reset switch; LAN, Fan fail indicator, Power indicators; 6 High-speed fans, UID button and LED, 1401 key American lock bezelBlvd. E., STE 4 | Bloomington, MN 55425 | PH: 1-855-440-4678 | scalelogicinc.com
System CPU/RAM/Drives
3.5 GHZ E5-1600, 32GB RAM, 2x240GB SSD HDD Mirrored
External I/O Ports
4x USB 3.0 rear Ports, 1x VGA Port, 2x RJ45 LAN Ports, 1x RJ45, Optional; 2x 10Gbit SFP Ports Dedicated IPMI LAN Port, plus 1x PCI-Express 3.0 x16 Slot for a FC HBA or other I/O.
Management Tools
Embedded web management uses standard HTTP - no host agent is required; local or remote, in-band or out-of-band management; easy to use monitoring and advanced error logging.
Event Notification
Email, Audible (buzzer), and visible (LED) alerts for bad drives and power supplies
Genesis IAP power server system and controller features Chassis
Sames as base server
System CPU/RAM/Drives
3.5 GHZ E5-2600, 64GB RAM, 2x240GB SSD HDD Mirrored
External I/O Ports
Sames as base server
Management Tools
Sames as base server
Event Notification
Sames as base server
Mechanical Specifications Voltage
100 – 140 V / 200 – 240 V, 60 – 50 Hz, 8.5 – 6 Amp
Power Supply
700W Redundant PS high-efficiency power supply with PMBus and I2C
Operating Wattage
220 Watts x 2 servers in HA
Operating Temperature
5°- 35°C (-40° +70°C non operational)
Relative Humidity
Maximum 90%
Dimensions
17.2 x 26.6 x 1.7 inch / 437.0 x 676.0 x 43.0 mm - Gross Weight: 46.0 lbs / 20.9 kg [approx.)
HyperFS File System Specifications System Capacity
64 ZB Theoretical Limit
Max number of files/objects/folders
Up to 4,000,000,000 when using 4TB metadata volume
File size
64 ZB Theoretical Limit
File name length
Windows: 255 ASCII characters; Linux/Mac: 255 ASCII characters
Directory depth
Windows: 244 characters
Linux: 4096 Bytes
Max number of LUNs
4093
Exported Paths
512
No. of Metadata controllers (MDC)
Up to 2, can be configured in HA mode
Number of concurrent file systems
16
Full redundancy configuration
Supported: No single point of failure
Dynamic file system expansion
Yes, LUNs can be added with no downtime
Supported SAN client OSs
Windows 7 32/x86_64/Win 8, Win 10
Windows 2008/2008_R2/2012/2012_R2/Server 32/x86_64/2016_x86_64
RHEL 5 (Update3-Uupdate10) 32/x86_64, RHEL 6 (Update0-Update8) 32/x86_64, RHEL 7 {Update0-Update2}
SUSE 11 SP1-3
OS X 10.7-10.12
SSD Support
Yes
Optional HyperFS Scale-Out NAS Specifications Number of nodes per cluster
64
Number of clusters
32
Supported Protocols
CIFS/SMBv1.0/v2.0
NFSv2/v3/v4, FTP/FTPS
HTTP/HTTPS/WebDAV
Scale-Out Nas OS
RHEL/CentOS 6.7 x86_64
Number of Scale-Out Nas Clients
CIFS clients: 2048 per node, NFS clients: No limit
FTP clients: 1GbE 800 clients and 10GbE 1600 clients
Number of shares mounted on client
CIFS on Windows Client: 23 NFS Client: 256
Supported OS of Scale-Out Nas clients
Windows 7/8/10
Windows 2008/2008_R2/2012/2012_R2 Server/2016 Server
CentOS/RHEL 4.x ; CentOS/RHEL 5 U1-U8; CentOS/RHEL 6.0-6.8, 7.0, 7.2
Suse11 SP1
OS X 10.6-10.12
Vmware/Hyper-V/KVM
FreeBSD-8.2
Solaris10
Genesis DS3 RAID controller/Drive chassis features Chassis
Modular compact 2U Steel and Aluminum Alloy enclosure with key lock drive cans and rack mount kit Dual FRU power supplies and embedded FRU RAID controllers
RAID Controllers
Dual redundant
Disk Drives
300GB 2.5” 15K SAS
External I/O Ports
Choose from up to 16Gb/s Fibre Channel, up to 10Gb/s iSCSI, or up to 12Gb/s SAS based on your needs and budget
System Cooling
Embedded cooling fans in power supplies
Operational Features RAID/Controller protection
RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, RAID migration, Configurable stripe size and write policy per system, Intelligent drive handling
Spare Drives
Genesis DS3 configurations can support hot and cold spare drives
Background Activities
Rebuild; drive monitoring; RAID fail-back, media health monitoring and repair
RAID Robustness
RAID controller active/active monitoring, physical drive error recovery, Replacement drive rebuild and monitoring, Bad Sector Re-mapping, Error recovery mechanisms and automated defect elimination.
System Management Supported OS
Windows, Mac OS X, HP-UX, Linux, Sun Solaris, OpenStack Cinder
Management Tools
Web-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus
Event Notification
Various event notification methods including email, LAN broadcast, fax, SNMP trap and SMS.
Mechanical Specifications Voltage
100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching)
Power Consumption
Two 530W, Frequency: 47-63 Hz
Operating Temperature
Operating: 0 to 40°C without BBU or CBM / 0 to 35°C with BBU or CBM
Relative Humidity
10 - 80%
Dimensions
448mm (W) x 88mm (H) x 500mm (D) **Without chassis ears / protrusions
Dimensions
448mm (W) x 88mm (H) x 500mm (D) **Without chassis ears / protrusions
The Genesis DS3 (GDS); High availability and high density dual controller 2U 24-bay storage designed for 2.5” drives. It provides non-stop power, improved energy efficiency, and easy deployment to handle your SMB and enterprise SAN/DAS applications. Get access to fast performance, convenient modular components, strong data integrity, friendly management, and extensive software bundles in one compact system.
Scale Logic, Inc. scalelogicinc.com 855-440-4678
Scale Logic, Europe BV scalelogicinc.com +31207606090
Find us on: YouTube, LinkedIn, Facebook and Twitter