Preview only show first 10 pages with watermark. For full document please download

Genesis Hypermdc Metadata Controllers

   EMBED


Share

Transcript

The Genesis HyperMDC 200D is a metadata cluster designed for ease-of-use and quick deployment. IPMI Control Dual Power Supplies Enhanced Metadata Uptime Storage Up to 1.3M IOPS and 5,500 MBps throughput SAS 15K RPM HDDs Dual Controller Pre-installed HyperFS/SONG SSD Mirrored Boot Drives Enterprise-class File System Platform HyperFS integrates high-performance SAN, Scale-Out NAS and data protection under one global namespace. Simplified Connectivity Plug-and-play with easy connectivity options that can be mixed and matched to support 8/16Gbit FC, 1/10/40Gbit SMB, NFS, and iSCSI Fully Redundant Metadata Built for low latency, leveraging dual controller RAID, dual servers and bonded network and fabric Genesis HyperMDC 200D Data Flow for SAN and Scale-Out NAS using HyperFS Data Flow HyperFS Client Protocol Open Protocols DATA SMB/NFS/HTTP(s)/FTP(s) Scale-Out NAS Gateways Metadata Controller Volumes DATA DATA up to PBs Drive Letter SONG Re-export META up to 4TB META Connect to Server Map Network Drive TA ME Mount Point Mount Point META SAN/BLOCK LAN/FILE Genesis IAP base server system and controller features Chassis Scale Logic, Inc. RoHS compliant 1U Steel and Aluminum Alloy enclosure with rack mount kit, dual FRU power supplies and fan assemblies and 6Gbit SAS Drive Backplane Power on/off switch; System reset switch; LAN, Fan fail indicator, Power indicators; 6 High-speed fans, UID button and LED, 1401 key American lock bezelBlvd. E., STE 4 | Bloomington, MN 55425 | PH: 1-855-440-4678 | scalelogicinc.com System CPU/RAM/Drives 3.5 GHZ E5-1600, 32GB RAM, 2x240GB SSD HDD Mirrored External I/O Ports 4x USB 3.0 rear Ports, 1x VGA Port, 2x RJ45 LAN Ports, 1x RJ45, Optional; 2x 10Gbit SFP Ports Dedicated IPMI LAN Port, plus 1x PCI-Express 3.0 x16 Slot for a FC HBA or other I/O. Management Tools Embedded web management uses standard HTTP - no host agent is required; local or remote, in-band or out-of-band management; easy to use monitoring and advanced error logging. Event Notification Email, Audible (buzzer), and visible (LED) alerts for bad drives and power supplies Genesis IAP power server system and controller features Chassis Sames as base server System CPU/RAM/Drives 3.5 GHZ E5-2600, 64GB RAM, 2x240GB SSD HDD Mirrored External I/O Ports Sames as base server Management Tools Sames as base server Event Notification Sames as base server Mechanical Specifications Voltage 100 – 140 V / 200 – 240 V, 60 – 50 Hz, 8.5 – 6 Amp Power Supply 700W Redundant PS high-efficiency power supply with PMBus and I2C Operating Wattage 220 Watts x 2 servers in HA Operating Temperature 5°- 35°C (-40° +70°C non operational) Relative Humidity Maximum 90% Dimensions 17.2 x 26.6 x 1.7 inch / 437.0 x 676.0 x 43.0 mm - Gross Weight: 46.0 lbs / 20.9 kg [approx.) HyperFS File System Specifications System Capacity 64 ZB Theoretical Limit Max number of files/objects/folders Up to 4,000,000,000 when using 4TB metadata volume File size 64 ZB Theoretical Limit File name length Windows: 255 ASCII characters; Linux/Mac: 255 ASCII characters Directory depth Windows: 244 characters Linux: 4096 Bytes Max number of LUNs 4093 Exported Paths 512 No. of Metadata controllers (MDC) Up to 2, can be configured in HA mode Number of concurrent file systems 16 Full redundancy configuration Supported: No single point of failure Dynamic file system expansion Yes, LUNs can be added with no downtime Supported SAN client OSs Windows 7 32/x86_64/Win 8, Win 10 Windows 2008/2008_R2/2012/2012_R2/Server 32/x86_64/2016_x86_64 RHEL 5 (Update3-Uupdate10) 32/x86_64, RHEL 6 (Update0-Update8) 32/x86_64, RHEL 7 {Update0-Update2} SUSE 11 SP1-3 OS X 10.7-10.12 SSD Support Yes Optional HyperFS Scale-Out NAS Specifications Number of nodes per cluster 64 Number of clusters 32 Supported Protocols CIFS/SMBv1.0/v2.0 NFSv2/v3/v4, FTP/FTPS HTTP/HTTPS/WebDAV Scale-Out Nas OS RHEL/CentOS 6.7 x86_64 Number of Scale-Out Nas Clients CIFS clients: 2048 per node, NFS clients: No limit FTP clients: 1GbE 800 clients and 10GbE 1600 clients Number of shares mounted on client CIFS on Windows Client: 23 NFS Client: 256 Supported OS of Scale-Out Nas clients Windows 7/8/10 Windows 2008/2008_R2/2012/2012_R2 Server/2016 Server CentOS/RHEL 4.x ; CentOS/RHEL 5 U1-U8; CentOS/RHEL 6.0-6.8, 7.0, 7.2 Suse11 SP1 OS X 10.6-10.12 Vmware/Hyper-V/KVM FreeBSD-8.2 Solaris10 Genesis DS3 RAID controller/Drive chassis features Chassis Modular compact 2U Steel and Aluminum Alloy enclosure with key lock drive cans and rack mount kit Dual FRU power supplies and embedded FRU RAID controllers RAID Controllers Dual redundant Disk Drives 300GB 2.5” 15K SAS External I/O Ports Choose from up to 16Gb/s Fibre Channel, up to 10Gb/s iSCSI, or up to 12Gb/s SAS based on your needs and budget System Cooling Embedded cooling fans in power supplies Operational Features RAID/Controller protection RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, RAID migration, Configurable stripe size and write policy per system, Intelligent drive handling Spare Drives Genesis DS3 configurations can support hot and cold spare drives Background Activities Rebuild; drive monitoring; RAID fail-back, media health monitoring and repair RAID Robustness RAID controller active/active monitoring, physical drive error recovery, Replacement drive rebuild and monitoring, Bad Sector Re-mapping, Error recovery mechanisms and automated defect elimination. System Management Supported OS Windows, Mac OS X, HP-UX, Linux, Sun Solaris, OpenStack Cinder Management Tools Web-based SANWatch management software RS232 serial port for local access to firmware-embedded utility Automated cache flush and caching mode operation per enclosure status Telnet and SSH system monitoring via Ethernet Platform-independent firmware management GUI LCD keypad panel for monitoring and access to all configuration options Module status LED indicators: component presence detection & thermal sensors via I2C bus Event Notification Various event notification methods including email, LAN broadcast, fax, SNMP trap and SMS. Mechanical Specifications Voltage 100VAC @ 10A to 240VAC @ 5A with PFC (auto-switching) Power Consumption Two 530W, Frequency: 47-63 Hz Operating Temperature Operating: 0 to 40°C without BBU or CBM / 0 to 35°C with BBU or CBM Relative Humidity 10 - 80% Dimensions 448mm (W) x 88mm (H) x 500mm (D) **Without chassis ears / protrusions Dimensions 448mm (W) x 88mm (H) x 500mm (D) **Without chassis ears / protrusions The Genesis DS3 (GDS); High availability and high density dual controller 2U 24-bay storage designed for 2.5” drives. It provides non-stop power, improved energy efficiency, and easy deployment to handle your SMB and enterprise SAN/DAS applications. Get access to fast performance, convenient modular components, strong data integrity, friendly management, and extensive software bundles in one compact system. Scale Logic, Inc. scalelogicinc.com 855-440-4678 Scale Logic, Europe BV scalelogicinc.com +31207606090 Find us on: YouTube, LinkedIn, Facebook and Twitter