Preview only show first 10 pages with watermark. For full document please download

Gfm-1500

   EMBED


Share

Transcript

® stored energy solutions for a demanding world GFM Series Model: GFM1500 The GFM range of gel technology batteries offers outstanding performance including a 15+ years design life. The GFM series is designed by using the polymer gel electrolyte and compliant with the latest IEC60896-21/22 standard. This GFM series also offers 100% capacity out of the box and is capable of handing deep discharges for complete peace of mind. The multiple installations to both horizontally and vertically are easily accessible due to the flexible connectors design. Specifications Battery Model GFM1500 2V Nominal Voltage 3HR( 370A, 1. 80V) 1125AH Width Height 10HR( 150A,1. 80V) 1500AH Length O Capacity( 25 C ) Dimensions 265. 5mm 229mm 1HR( 825A, 1. 75V) 825AH Total Height 555mm Approx. Weight 566mm 93kg Internal Resistance 0.15mΩ Max Charge Current Allowed 375A O Ch arge Voltage( 25 C ) Cycle use Float use 2. 35V / cell 2. 25V / cell O O O O Operation ( maximum ): -40 C to 5 5 C( -40 F to 1 31 F) O O O O Operation ( recommended ): 15 C to 25 C( 59 F to 77 F) O O O Storage: -20 C to 40 C( -4 F to 104 O F) Temperature Ranges Terminal M8 Female Terminal Hardware Torque 15 ± 1. 0Nm Container Material ABS (V0 optional) Constant Current Discharge Characteristics Units: Amperes (25OC, 77OF) End voltage per cell 1.60V 1.65V 1.70V 1.75V 1.80V 1.85V 1.90V 5min 15min 30min 1hr 2hr 3hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 2182.6 2046.7 1923.5 1814.5 1714.2 1471.7 1836.5 1728.6 1635.8 1539.6 1435.9 1221.4 1492.4 1361.0 1244.6 1147.6 1074.5 944.7 983.5 928.2 882.0 826.8 784.5 698.4 605.6 588.4 568.2 547.3 530.8 478.5 444.6 432.6 413.2 403.7 391.2 362.1 287.8 284.2 277.1 272.4 264.3 249.4 247.9 245.0 239.1 235.5 229.3 218.3 194.1 192.4 189.7 187.1 182.0 176.2 159.2 158.3 155.8 154.5 152.4 146.2 73.8 72.7 72.4 71.7 70.2 68.2 39.4 39.1 38.8 38.3 37.6 35.8 22.1 21.8 21.4 20.8 20.2 19.5 1205.4 964.3 785.0 574.0 400.0 321.9 225.9 197.0 158.8 133.2 63.7 33.5 18.0 8hr 424.3 408.6 399.7 384.9 375.0 362.7 339.3 10hr 346.4 338.1 328.1 323.2 318.3 305.9 283.7 Discharge Data with Constant Power E n d v o lta g e p e r c e ll 1.60V 1.65V 1.70V 1.75V 1.80V 1.85V 1.90V 5min 4239.5 4032.1 3876.5 3755.5 3651.8 3321.0 2930.9 15min 3550.6 3407.4 3286.4 3163.0 3014.8 2745.7 2382.7 Copyright © Tysonic Battery 30min 2827.2 2674.1 2607.4 2518.5 2429.6 2160.5 1822.2 1hr 2013.2 1860.2 1771.4 1702.3 1662.9 1512.4 1302.7 O O Units:Watts per cell (25 C, 77 F) 2hr 1299.0 1191.6 1157.1 1116.1 1095.4 1006.6 873.4 3hr 962.2 903.0 870.9 838.8 809.2 766.3 710.5 4hr 767.3 727.8 703.1 688.3 666.1 640.5 596.3 5hr 635.5 613.3 599.5 584.7 568.4 541.8 506.3 6hr 542.8 525.5 515.1 503.3 488.5 462.6 432.2 24hr 156.2 153.2 150.2 148.8 146.5 140.6 131.7 www.tysonicbattery.com ® stored energy solutions for a demanding world GFM Series Model: GFM1500 265.5 229 M8 20bolt 555 566 washer valve terminal cover shell 86 C h a rg e C a p a city C h a rg e C u rre n t C h a rg e V o lta g e 108 86 (%) (CA) (V) Charge Characteristic Self-discharge Characteristic Constant Charge At 0.10CA2.35V(٢٥OC) Charge Voltage 100 Capacity(%) Charge Capacity 100 %Discharge 50 %Discharge 75 10 OC(50 OF) 50 40 OC (104 OF) 30 OC (86 OF) 3 9 20 OC(68 OF) 25 Charge Current Time(hour) 6 12 15 18 21 24 27 Storage Time(month) Relationship Between Charging Voltage and Temperature C ha r gi n g V o lt a g e ( V ) Capacity(%) Temperature Effects on Capacity Cycle use TYSONIC BATTERY INC. 1032 East Main Street . Alhambra, CA 91801 USA Toll Free: 877-897-6648 . Tel: (626) 289-5962 . Fax: (626) 576-2503 http://www.tysonicbattery.com . Email: [email protected] Standby use