Preview only show first 10 pages with watermark. For full document please download

Gfm-800

   EMBED


Share

Transcript

® stored energy solutions for a demanding world GFM Series Model: GFM800 The GFM range of gel technology batteries offers outstanding performance including a 15+ years design life. The GFM series is designed by using the polymer gel electrolyte and compliant with the latest IEC60896-21/22 standard. This GFM series also offers 100% capacity out of the box and is capable of handing deep discharges for complete peace of mind. The multiple installations to both horizontally and vertically are easily accessible due to the flexible connectors design. Specifications Battery Model GFM800 2V Nominal Voltage 3HR( 200A, 1. 80V) 600AH Width Height 10HR( 80A,1. 80V) 800AH Length O Capacity( 25 C ) Dimensions 229mm 154mm 555mm Approx. Weight 52.7kg Internal Resistance 0.22mΩ Max Charge Current Allowed 200A O Ch arge Voltage( 25 C ) 1HR( 440A, 1. 75V) 440AH Total Height 566mm Cycle use Float use 2. 35V/cell 2. 25V / cell O O O O Operation ( maximum ): -40 C to 5 5 C( -40 F to 1 31 F) O O O O Operation ( recommended ): 15 C to 25 C( 59 F to 77 F) O O O Storage: -20 C to 40 C( -4 F to 104 O F) Temperature Ranges Terminal M8 Female Terminal Hardware Torque 15 ± 1. 0Nm Container Material ABS (V0 optional) Constant Current Discharge Characteristics Units: Amperes (25OC, 77OF) End voltage per cell 5min 1.60V 1164.0 1.65V 1091.5 1.70V 1025.9 1.75V 967.7 1.80V 914.2 1.85V 784.9 1.90V 642.9 15min 30min 1hr 2hr 3hr 5hr 6hr 8hr 10hr 24hr 48hr 100hr 979.5 921.9 872.4 821.1 765.8 651.4 795.9 725.9 663.8 612.1 573.1 503.8 524.5 495.1 470.4 441.0 418.4 372.5 323.0 313.8 303.0 291.9 283.1 255.2 237.1 230.7 220.4 215.3 208.6 193.1 155.0 153.1 149.3 146.7 142.4 134.4 133.6 132.0 128.8 126.9 123.5 117.6 104.6 103.7 102.2 100.8 98.1 94.9 85.7 85.3 83.9 83.2 82.1 78.8 39.7 39.2 39.0 38.7 37.8 36.7 21.2 21.1 20.9 20.6 20.3 19.3 11.9 11.7 11.5 11.2 10.9 10.5 514.3 418.7 306.1 213.3 171.7 121.7 106.1 85.6 71.8 34.3 18.0 9.7 Discharge Data with Constant Power E n d v o lta g e p e r c e ll 1.60V 1.65V 1.70V 1.75V 1.80V 1.85V 1.90V 5min 15min 30min 2272.4 2161.3 2077.9 2013.0 1957.4 1780.1 1571.0 1903.2 1826.4 1761.6 1695.4 1616.0 1471.7 1277.2 1515.4 1079.1 1433.3 997.1 1397.6 949.5 1350.0 912.5 1302.3 891.3 1158.1 810.6 976.7 698.2 Copyright © Tysonic Battery 1hr O O Units:Watts per cell (25 C, 77 F) 2hr 3hr 4hr 5hr 6hr 8hr 10hr 24hr 696.3 638.7 620.2 598.3 587.2 539.5 468.1 515.7 484.0 466.8 449.6 433.8 410.7 380.9 411.3 390.1 376.9 369.0 357.1 343.3 319.6 340.7 328.8 321.3 313.4 304.7 290.4 271.4 290.9 281.7 276.1 269.8 261.8 248.0 231.7 227.4 219.0 214.2 206.3 201.0 194.4 181.9 185.7 181.2 175.9 173.2 170.6 164.0 152.1 83.7 82.1 80.5 79.7 78.6 75.4 70.6 www.tysonicbattery.com ® stored energy solutions for a demanding world GFM Series Model: GFM800 154 229 M8 20bolt cover 555 566 washer valve terminal shell C h a rg e C a p a city C h a rg e C u rre n t C h a rg e V o lta g e 108 69 (%) (CA) (V) Charge Characteristic Self-discharge Characteristic Constant Charge At 0.10CA2.35V(٢٥OC) Charge Voltage 100 Capacity(%) Charge Capacity 100 %Discharge 50 %Discharge 75 10 OC(50 OF) 50 40 OC (104 OF) 30 OC (86 OF) 3 9 20 OC(68 OF) 25 Charge Current Time(hour) 6 12 15 18 21 24 27 Storage Time(month) Relationship Between Charging Voltage and Temperature C ha r gi n g V o lt a g e ( V ) Capacity(%) Temperature Effects on Capacity Cycle use TYSONIC BATTERY INC. 1032 East Main Street . Alhambra, CA 91801 USA Toll Free: 877-897-6648 . Tel: (626) 289-5962 . Fax: (626) 576-2503 http://www.tysonicbattery.com . Email: [email protected] Standby use