Gfmj-800 - Innovative Energies

   EMBED


Share

Transcript

GFMJ-800 (8 OPzV 800) Features • VRLA gel battery with ABS case • Design life 20 years • Cyclic and standby duty • High cycle service life • Good temperature resistance performance • Excellent deep cycle performance • Superior low current discharge performance • Tubular type positive plate • PVC- SiO2 separator • Double sealed copper core lead terminals • Reliable opening and closing safety valve Dimensions • 210 x 191 x 677mm H Rated voltage 2V Capacity@ 25℃ 800Ah @ 10hr Weight about 62kg ( 136.4 lb) to 1.80V per cell Reference internal resistance About 0.32mΩ@ 25℃ (charged) Short-circuit current About 6297A (0.1S reference value) Max discharge current 2400A (5sec) Self-discharge ﹤20%/180 days @ 25℃ Temperature range Application: -20℃~50℃ Storage: -20℃~50℃ Recommendation: 20℃~30℃ Max charge current 160A Charge voltage @ 25℃ Float charge: 2.23V, average charge: 2.35V Temperature compensation factor: -3 mV/℃ Terminal output M10 copper terminal (HPb59-1) 2014-01 Innovative Energies Ltd. 1 Heremai Street, Henderson NZ. Tel: +64 9 835 0700. [email protected]. www.innovative.co.nz GFMJ-800 (8 OPzV 800) Discharge current at different final voltages and different discharge rates 5min 10min 15min 30min 45min 1hr 1.5hr 2hr 3hr 1.90 684 599 404 392 376 312 248 220 172 1.85 721 630 470 440 399 344 272 236 183 1.80 773 762 649 560 448 416 344 266 200 1.75 804 778 744 624 497 448 358 278 208 unit: 4hr 144 152 164 168 Discharge power at different final voltages and different discharge rates 1.90 1.85 1.80 1.75 5min 1296 1340 1421 1470 10min 15min 30min 45min 1123 740 654 616 1170 852 739 675 1402 1028 911 832 1422 1185 1030 942 1hr 578 611 753 853 1.5hr 489 531 651 724 Upo(V) 2hr 400 451 549 595 A (25℃) 5hr 124 130 139 141 8 hr 86 90 96 98 10 hr 72 75 82 83 8 hr 174 190 213 217 10 hr 150 164 182 184 20hr 37.08 40.78 42.81 44.52 100 hr 9.67 10.18 10.53 10.79 120hr 8.20 8.64 8.94 9.16 unit: W (25℃) 3hr 329 368 437 464 4hr 278 308 358 380 5hr 239 265 304 317 Current Voltage (I10A) (V) 20hr 100 hr 120hr 79.1 19.3 16.4 85.7 20.1 17.1 93.9 20.6 17.5 95.9 20.8 17.6 Quantity of electricity (%) 2.2 1.2 2.40 1.0 2.30 0.8 2.20 0.6 2.10 Charge Voltage 2.1 2.0 1.9 20HR 120HR 1.8 2HR 0.4 2.00 0.2 1.90 0 1.80 75 50 25% DOD 50% DOD 75% DOD 100% DOD 5HR 8HR 10HR 1HR 0. 1 0. 5 1 2 5 10 20 120 Discharge time(h) 25 Charge Current 1.7 0. 01 100 Battery capacity 4 0 8 12 16 24 32 40 48 Duration of Charge (h) Figure 1 Discharge characteristic curve (20℃) Figure 2 Constant voltage charge characteristic curve 120HR 20HR 120 Capacity (%) 10HR 100 8HR 80 4HR 2HR 60 Residual Capacity(%) 100 140 0 °C 80 1 0 °C 60 20° C 40 40° C 40 30° C 20 20 -20 -10 0 10 20 30 40 50 Temperature(℃) 0 3 6 9 12 15 21 18 24 S to ra g e T im e ( m o n th ) F ig u r e 4 S e lf -d is c h a rg e c h a ra c te r is tic c u r v e Figure 3 Relation curves between capacity and temperature 2014-01 Innovative Energies Ltd. 1 Heremai Street, Henderson NZ. Tel: +64 9 835 0700. [email protected]. www.innovative.co.nz